12

Pagine int.MPF italiano

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Pagine int.MPF italiano
Page 2: Pagine int.MPF italiano

New

absolute filter elements

independently tested

in the following Institutes:

MPFMPF series filters are designed for return lines, and

are installed semi-immersed in a reservoir.

Continued Research & Development on both the fil-

ter bodies and the filter elements has resulted in a

product line with excellent pressure drop characteristics

combined with a high filtration efficiency. The high

flow rate bypass valves are a standard feature with

this range of product.

MPF filters within this range are suitable for flow

rates up to 750 l/min.

MPF filter series, are a 2,3 and 4 bolt fixing design

MPF series are specifically designed for use in

mobile applications, agricultural machinery and

power units.

D e s c r i p t i o n

PRESSURE ALUMINIUM DIE CAST

TANK FLANGE O-RING

OPTIONALEXTENSION

TUBE

MPF 02030/6.99/UK Reply. 3.98

HIGH EFFICIENCY ELEMENT WITH HIGH

DIRT HOLDING CAPACITY

COVER

COMBINED SCREW-WASHER

FILTER ELEMENT LENGTH OPTIONS

NYLON BOWL

FULLY RESPONSIVE BYPASS VALVE

REMOVAL HANDLE

CAPTIVE O-RING SEAL

2

UNI EN ISO 9001N° 037/98

INDICATOROPTIONS

VISUAL

ELECTRICAL

È

È

Page 3: Pagine int.MPF italiano

Element materialNominal filtration

Inorganic microfibre with acrilic support

A Series

Resin - impregnated paper

P Series

New improved ß ≥ 200filter elements withgreater efficiency andincreased dirt holding capacity

Contamination retentionas per ISO 4572: Multi-pass test.

∆ P(bar)ß ≥ 2

(50%)ß ≥ 20(95%)

ß ≥ 75(98,7%)

ß2 ß10 ß20

ß ≥ 200(99,5%)

Dimensions for ß (µm) valuesFilter

elements

A03

A06

A10

A25

3

13

2

3

6

19

2,4

4,6

7,8

22

3

6

10

25

> 10.000

> 2.000

≥ 200

> 1,5

> 10.000

> 10.000

> 10.000

> 35

7

7

7

7

20

8

1,5

Filtration ratios

N.B. Other materials giving different degrees of filtration are available on request.

Values in cm2

Filtering area Filter elements H - ∆P 10 bar

Filtering areaFilter elements N - ∆P 3 bar

Square wire mesh (filtration degree is definedin microns by the maximum diameter of asphere corresponding to the mesh size)

M Series

Element materialAbsolute filtration

MP Filtr i - Fi ltration technology

3

Type MF

A03/A06

A10/A25

030-1

335

335

100-1

630

630

100-2

1000

1000

100-3

1730

1730

180-1

4300

4300

180-2

7500

7500

400-1

4740

4740

400-2

6930

6930

400-3

8760

8760

750-1

11400

11400

Values in cm2

Type MF

P10/P25

M25

M60

M90

030-1

410

290

290

290

100-1

1020

460

460

460

100-2

1660

730

730

730

100-3

1900

1250

1250

1250

180-1

4000

2000

2000

2000

180-2

8000

4500

4500

4500

400-1

4480

2410

2000

2000

400-2

6550

3520

3000

3000

400-3

8280

4450

3840

3840

750-1

13450

7250

6250

5500

Materials

ISO 2941 - Verification of collapse/burst resistance.

ISO 2942 - Verification of fabrication integrity and determination

of the first bubble point.

ISO 2943 - Verification of material compatibility with fluids.

ISO 3723 - Method for end load test.

ISO 3724 - Verification of flow fatigue characteristics.

ISO 3968 - Evaluation of pressure drop versus flow characteristics.

ISO 4572 - Multi-pass method for evaluating filtration performance.

MP Filter elements - Conform to the following ISO standards

External wire mesh

Microfibre filtration mediaInternal wire mesh

Inner supporttube

External support media

Internal support media

End caps:Nylon

Support tube:Galvanized steel

Support frames:Coated wire mesh

A SeriesInorganic microfibre

Filter element:

Page 4: Pagine int.MPF italiano

water - glycol (types HFC as per ISO 6743/4)

V SeriesViton compatible with synthetic fluids(types HS-HFDR-HFDS-HFDU as per ISO 6743/4)

Bypass valve

SealsA Series: Nitrile (Buna-N)V Series: Viton

Filter head and bowlscompatible for use with:• mineral oils

(types HH-HL-HM-HR-HV-HG as per ISO 6743/4)• water-based emulsions

(types HFAE-HFAS as per ISO 6743/4)• synthetic fluids

(types HS-HFDR-HFDS-HFDU as per ISO 6743/4)• water-glycol

(types HFC as per ISO 6743/4)Ask for anodized version

Collapse pressurefilter elements

M P F i l t r i - S p e c i f i c a t i o n

N Series 3 barH Series 10 bar

From -25 to +110°CFor temperatures outside this range, please consult our Sales Network Organization

Workingtemperature

Fatigue test: a filter body subjected to pressure impulses from 0 to 3 bar will withstand 1.000.000 cycles

Pressure filterbody Maximum working pressure up to 3 bar

Test pressure: 5 barMinimum burst pressure: 10 bar

B: 1.75 bar ± 10%Bypass valve, differential opening pressure:Bypass valveCalibration pressure

Materials

Pressure die cast aluminium

CoverMPF 030-100 NylonMPF 180-750 Aluminium

Nylon - Steel (MPF 180-2/184-2 only)

Head

Compatibilitywith fluids

Brass

Nylon

Bowl Indicator

1.3 bar ± 10%

Description:MPF series filters are fitted with indicators switching at a pressure of

Types of indicators

Electrical indicatorOperational information:Max voltage: 48 Vac 50÷60 HzMax current: 0.5 A resistive, 0.2 A inductive.

ER Series:Pressure switch with N.O. contactsEC Series:Pressure switch with N.C. contacts

V1 Series (botton connection)VR Series (rear connection) (MPF 184, only)

Visual indicatorColour coded pressure gaugescale 0÷6 bar

SealsA SeriesNitrile (Buna-N) compatible with mineral oils(types HH-HL-HM-HR-HV-HG as per ISO 6743/4)water - based emulsions(types HFAE-HFAS as per ISO 6743/4)

Filter elementsAs per ISO 2943; suitable for mineral oils(types HH-HL-HM-HR-HV-HG as per ISO 6743/4) synthetic fluids (A and M series only) (types HS-HFDR-HFDS-HFDU as per ISO 6743/4)

For water-based emulsions (types HFAE-HFAS as per ISO 6743/4) and fluids other than those mentioned, please consult our Sales Network Organization.

4

Filter body:

Page 5: Pagine int.MPF italiano

Absolute inorganic microfibrefiltration media, available in3, 6, 10 and 25 micronExample - A03, A06, A10 or A25

S e l e c t i o n& i n s t a l l a t i o n i n f o r m a t i o n

Filter elementstypes

A Series P SeriesNominal cellulose impregnatedpaper media, available in 10 and 25 micron.Example - P10 or P25

M SeriesMetal mesh media, available in25, 60, and 90 micron.Example - M25, M60 or M90.

Type

1

2

3

H

100

150

225

H1

120

170

250

ø B

29

29

43

Lengths

Filterassembly

Flow ratel/min*

Bowllength

Port sizeBSP/NPT/SAE

Weightkg**

MPF SERIES 100 SIZE

Type

G1

G4

G7

A

1/2” BSP

1/2” NPT

SAE 8 - 3/4” - 16 UNF

Threadconnections

Type

G1

G2

G3

G4

G5

G6

G7

G8

G9

A

1/2” BSP

3/4” BSP

1” BSP

1/2” NPT

3/4” NPT

1” NPT

SAE 8 - 3/4” - 16 UNF

SAE 12 - 1 1/16” - 12 UN

SAE 16 - 1 5/16” - 12 UN

Threadconnections

Please refer to individual pressure drop curves to obtain filter assembly pressure drop information

The following filter sizing recommendations are based using a mineral oil fluid at 30 mm2/s (cSt) with a maximum total filter assembly(housing and filter element) pressure drop of 30% of the filter condition indicator (0.4 bar)

** Flow rates with 30 mm2/s fluid viscosity** Weight including filter element

** Flow rates with 30 mm2/s fluid viscosity** Weight including filter element

MPF 100

22

100

568

86

20

51

ø66

ø7

A

ø90

R10

1/2”

0,40

0,30

0,20

0,10

0,000 25 50 75 100 125

∆p b

ar

ø25

Ø 60

Housing pressure drop curve

Holes on the tank

IN

V1 ER - EC

V1 ER - EC

Flow rate l/min

∆p b

ar

28

H1

75

12

H

24

67.5

ø88

ø 8.5

1/2”

1”

3/4”

A

ø 1

15

R10

0,40

0,30

0,20

0,10

0,000 50 100 150 200 250

øB

Ø 80

Housing pressure drop curve

Flow rate l/min

MPF SERIES 030 SIZE

5

MPF 030

A03

A06

A10

A25

P10

10

12

24

35

33

1 1/2” 0,5

Filterassembly

Flow ratel/min*

Bowllength

Port sizeBSP/NPT/SAE

Weightkg**

A03

A06

A10

A25

P10

A03

A06

A10

A25

P10

A03

A06

A10

A25

P10

28

33

35

75

55

35

42

50

140

100

45

55

75

170

125

1

2

3

1/2”

3/4”

3/4”

1”

3/4”

1”

1,0

1,2

1,5

26

ø 40

ø 30

A/F.141/8” BSP 1/8” BSP

Pg75643

31

A/F.24

26

ø 40

ø 30

A/F.141/8” BSP 1/8” BSP

Pg7

5643

31

A/F.24

INDICATOR PORT

INDICATOR PORT

90

No. 2 Holes M6

ø 67

Holes on the tank

IN

115

No. 2 Holes M6

ø 89

Page 6: Pagine int.MPF italiano

S e l e c t i o n& i n s t a l l a t i o n i n f o r m a t i o n

MPF SERIES 184 SIZE

Flange connections

Threadconnections

Dual port option availables - See ordering information Flange port option availables - See ordering information** Flow rates with 30 mm2/s fluid viscosity** Weight including filter element

MPF 184

35

250

8912

H

32

120°

15 °

96

ø129

ø110

ø40.5

A

ø175

ø10.7

R9.5

43

E

250

103

11

H

31

32

86 86

ø125.5

ø110

56Pg 7

ø 40.5

ø 3

0

6

Filterassembly

Flow ratel/min*

Bowllength

Port sizeBSP/NPT/SAE

Weightkg**

Type

G1

G4

G7

A

1 1/4” BSP

1 1/4” NPT

SAE 20 - 1 5/8” - 12 UN

Type

G1

G2

G4

G5

G7

G8

A

1 1/4” BSP

2 Ports 1 1/4” BSP

1 1/4” NPT

2 Ports 1 1/4” NPT

SAE 20 - 1 5/8” - 12 UN

2 Ports SAE 20 - 1 5/8” - 12 UN

E

1/8” BSP

1/8” BSP

1/8” NPT

1/8” NPT

1/8” NPT

1/8” NPT

Type

F1

F2

F3

F4

A

1 1/2” SAE 3000 PSI/M

1 1/2” SAE 3000 PSI/UNC

2 Ports 1 1/2” SAE 3000 PSI/M

2 Ports 1 1/2” SAE 3000 PSI/UNC

B

69,85

69,85

69,85

69,85

C

35,71

35,71

35,71

35,71

D

M12

1/2” UNC

M12

1/2” UNC

E

1/8” BSP

1/8” NPT

1/8” BSP

1/8” NPT

Threadconnections

** Flow rates with 30 mm2/s fluid viscosity** Weight including filter element

A03

A06

A10

A25

P10

100

120

150

300

190

1 1 1/4” 2,2

LengthH

231

A03

A06

A10

A25

P10

210

270

320

360

345

2 1 1/4” 3,6450

Filterassembly

Flow ratel/min*

Bowllength

Port sizeBSP/NPT/SAE

Weightkg**

A03

A06

A10

A25

P10

100

120

150

300

190

1 1 1/4” 2,5

LengthH

230

A03

A06

A10

A25

P10

210

270

320

360

345

2 1 1/4” 3,9449

Please refer to individual pressure drop curves to obtain filter assembly pressure drop information

The following filter sizing recommendations are based using a mineral oil fluid at 30 mm2/s (cSt) with a maximum total filter assembly(housing and filter element) pressure drop of 30% of the filter condition indicator (0.4 bar)

MPF SERIES 180 SIZE

MPF 180

MPF 180 & 184Housing pressure drop curve

1 1/4”

0,40

0,30

0,20

0,10

0,000 75 150 225 300 375

∆p b

ar

Flow rate l/min

*

43

34ø 40

A/F.24

A/F.14

1/8”

BSP

1/8”

BSP

26

ø 40

ø 30

A/F.141/8” BSP 1/8” BSP

Pg7

5643

31

A/F.24

A

R 11

Port “2”

90°

45°

Port “1”

n°4 holes ø11

ø159

AB

C

D

V1 ER - EC

ER - EC

VR

Holes on the tank

IN

15°

120°

120°

No. 3 Holes M10

ø 130

ø 175

Holes on the tank

IN IN

45°

90°

No. 4 Holes M10ø 159

ø 127

INDICATOR PORT

INDICATOR PORT

Page 7: Pagine int.MPF italiano

S e l e c t i o n& i n s t a l l a t i o n i n f o r m a t i o n

MPF 750

MPF 400

A

ø220

4 holes ø11.5

R10

30°

90°

48.5

450

105

14

430

126

ø173.5

44

ø64

2”

0,40

0,30

0,20

0,10

0,000 150 300 450 600 750

∆p b

ar

Housing pressure drop curve

Flow rate l/min

7

MPF SERIES 750 SIZE

Filterassembly

Flow ratel/min*

Bowllength

Port sizeBSP/NPT/SAE

Weightkg**

** Flow rates with 30 mm2/s fluid viscosity** Weight including filter element

A03

A06

A10

A25

P10

250

300

400

575

440

1 2” 7,0

Type

1

2

3

H

178

238

288

H1

200

250

310

ø B

51

64

64

Lengths

Please refer to individual pressure drop curves to obtain filter assembly pressure drop information

The following filter sizing recommendations are based using a mineral oil fluid at 30 mm2/s (cSt) with a maximum total filter assembly(housing and filter element) pressure drop of 30% of the filter condition indicator (0.4 bar)

MPF SERIES 400 SIZE

Type

G1

G2

G3

G4

G5

G6

G7

G8

G9

A

1 1/4” BSP

1 1/2” BSP

2” BSP

1 1/4” NPT

1 1/2” NPT

2” NPT

SAE 20 - 1 5/8” - 12 UN

SAE 24 - 1 7/8” - 12 UN

SAE 32 - 2 1/2” - 12 UN

Threadconnections

** Flow rates with 30 mm2/s fluid viscosity** Weight including filter element

Filterassembly

Flow ratel/min*

Bowllength

Port sizeBSP/NPT/SAE

Weightkg**

A03

A06

A10

A25

P10

A03

A06

A10

A25

P10

A03

A06

A10

A25

P10

120

150

170

340

280

170

200

260

450

320

220

270

320

500

420

1

2

3

1 1/4”

1 1/2”

1 1/2”

2”

2”

3,0

3,5

3,7

Flange connections

Type

G1

G4

G7

A

2” BSP

2” NPT

SAE 32 - 2 1/2” - 12 UN

Threadconnections

Type

F1

F2

A

2” SAE 3000 PSI/M

2” SAE 3000 PSI/UNC

B

77,77

77,77

C

42,88

42,88

D

M12

1/2” UNC

38.5

H1

98.5

13

H

1 1/4” 1 1/2”

2”A

44

115.5

ø173.5

146

øB

ø220

4 holes ø11.5

R10

30°

90°

0,40

0,30

0,20

0,10

0,000 150 300 450 600 750

∆p b

ar

Housing pressure drop curves

Flow rate l/min

26

ø 40

ø 30

A/F.141/8” BSP 1/8” BSP

Pg7

5643

31

A/F.24

D B

A

C

D B

A

C

26

ø 40

ø 30

A/F.141/8” BSP 1/8” BSP

Pg7

5643

31

A/F.24

V1 ER - EC

V1 ER - EC

INDICATOR PORT

INDICATOR PORT

Holes on the tank

IN

30°

90°

No. 4 Holes M10

ø 220

ø 175

Holes on the tank

IN

30°

90°

No. 4 Holes M10

ø 220

ø 175

Page 8: Pagine int.MPF italiano

• Customer requires a 160 l/min filter assembly

• Mineral oil fluid: ISO VG 68 (68 mm2/s (cSt) at 40°C)

• A25 - 25 micron absolute filtration

Selection :

•Housing pressure drop - MPF 180 - 184 with 160 l/min ∆p = 0.06 bar (see curve on page 6)

•Filter element pressure drop (brochure viscosity) - MF 180.1.A25HB with 160 l/min ∆p = 0.13 bar (see curve on page 9)

•Filter element pressure drop (working viscosity) - With 68 mm2/s (cSt) ∆p1 = 0.13 x ( 68/30 ) = 0.30 bar

•Filter assembly pressure drop ∆p Total = ∆p Housing + ∆p1 Filter element = 0.06 + 0,30 = 0,36 bar* { Acceptable pressure drop value,as per our recommendations

The curves were obtained using a

mineral oil with a density of 0,86 kg/dm.

The ∆p varies proportionally to the density.

3

GeneralPressure drop versus flow rate curve information for both housing and filter elements is in accordance with ISO 3968

Filter assembly pressure drop - ∆p Total = ∆p Housing + ∆p Filter element

Housing pressure drop - The housing pressure drop is proportional to the fluid density

Filter element pressure drop - Filter element pressure drop is proportional to kinematic viscosity therefore always check thefluid operating temperature and fluid type to obtain the working viscosity according to the following formula:

4,0

3,0

2,0

1,0

0,00 15 30 45 60 75 90

∆p b

ar

Flow rate l/min

4,0

3,0

2,0

1,0

0,00 25 50 75 100 125 150

∆p b

ar

Flow rate l/min

MPF 030 MPF 100

4,0

3,0

2,0

1,0

0,00 50 100 150 200 250 300

∆p b

ar

Flow rate l/min

4,0

3,0

2,0

1,0

0,00 100 200 300 400 500 600

∆p b

ar

Flow rate l/min

MPF 180 - 184 MPF 400 - 750

P r e s s u r e d r o p i n f o r m a t i o n

Fi l ter assembly s iz ing example

B y p a s s v a l v e s p r e s s u r e d r o p

8

Brochure viscosity 30 mm2/s (cSt)

∆p1 Filter element = (working viscosity/brochure viscosity) x ∆p filter element

Page 9: Pagine int.MPF italiano

The curves were obtained using a mineral oil with a kinematic viscosity of 30 mm2/s (cSt).The ∆p varies proportionally to the fluid kinematic viscosity. For the metal mesh filter elements

curves (M series), please consult ourSales and Network Organization

The curves were obtained using a mineral oil with a kinematic viscosity of 30 mm2 /s (cSt).The ∆p varies proportionally to the fluid kinematic viscosity.

F i l t e r e l e m e n t s - N - ∆ P 3 b a r

F i l t e r e l emen ts - H - ∆P 10ba r

*Example: See page 8 9

MF 100 - 3 P...N

0

1,00

0,75

0,50

0,25

0,0025 50 75 100 125 150

∆p b

ar

Flow rate l/min

MF 100 - 1 P...N

0

1,00

0,75

0,50

0,25

0,0025 50 75 100 125 150

∆p b

ar

Flow rate l/min

0

1,00

0,75

0,50

0,25

0,0075 150 225 300 375 450

∆p b

ar

Flow rate l/min

MF 100 - 2 P...N

0

1,00

0,75

0,50

0,25

0,0025 50 75 100 125 150

∆p b

ar

Flow rate l/min

MF 400 - 2 P...N

0

1,00

0,75

0,50

0,25

0,00100 200 300 400 500 600

∆p b

ar

MF 400 - 3 P...N

0

1,00

0,75

0,50

0,25

0,00100 200 300 400 500 600

∆p b

ar

Flow rate l/minFlow rate l/min

MF 750 - 1 P...N

0

1,00

0,75

0,50

0,25

0,00125 250 375 500 625 750

∆p b

arFlow rate l/min

MF 400 - 1 P...N

0

1,00

0,75

0,50

0,25

0,0075 150 225 300 375 450

∆p b

ar

Flow rate l/min

MF 030 - 1 P...N

0

1,00

0,75

0,50

0,25

0,0015 30 45 60 75 90

∆p b

ar

Flow rate l/min

P10

P25

P10

P25

P10

P25

P10

P25P10

P25

MF 180 - 1 P...N

0

1,00

0,75

0,50

0,25

0,0050 100 150 200 250 300

∆p b

ar

Flow rate l/min

P10

P25

P10

P25

P10

P25

P10

P25

P10

P25

MF 180 - 2 P...N

MF 100 - 1 A...H

0

1,00

0,75

0,50

0,25

0,0025 50 75 100 125 150

∆p b

ar

Flow rate l/min

MF 100 - 2 A...H

0

1,00

0,75

0,50

0,25

0,0025 50 75 100 125 150

∆p b

ar

Flow rate l/min

MF 100 - 3 A...H

0

1,00

0,75

0,50

0,25

0,0025 50 75 100 125 150

∆p b

ar

Flow rate l/min

MF 400 - 1 A...H

0

1,00

0,75

0,50

0,25

0,0075 150 225 300 375 450

∆p b

ar

Flow rate l/min

MF 400 - 2 A...H

0

1,00

0,75

0,50

0,25

0,00100 200 300 400 500 600

∆p b

ar

Flow rate l/min

MF 400 - 3 A...H

0

1,00

0,75

0,50

0,25

0,00100 200 300 400 500 600

∆p b

ar

Flow rate l/min

MF 750 - 1 A...H

0

1,00

0,75

0,50

0,25

0,00125 250 375 500 625 750

∆p b

ar

Flow rate l/min

A10A06A03

A25

A10A06A03

A25

A10A06A03

A25

A10

A06A03

A25

A10

A06A03

A25

A10A06A03

A25

A10A06A03

A25

MF 180 - 1 A...H

0

1,00

0,75

0,50

0,25

0,0050 100 150 200 250 300

∆p b

ar

Flow rate l/min

A10

A06A03

A25

*

MF 030 - 1 A...H

0

1,00

0,75

0,50

0,25

0,0015 30 45 60 75 90

Flow rate l/min

A10A06A03 A25

0

1,00

0,75

0,50

0,25

0,0075 150 225 300 375 450

∆p b

ar

Flow rate l/min

A10A06

A03

A25

MF 180 - 2 A...H

Page 10: Pagine int.MPF italiano

The filter element has a handle on the top allowing easyremoval of itself from the bowl.

The helical spring is utilized to secure the filter element in its location.

Fi l te r e lement r ep lacement

Appl icat ions

Example of application

10

Extension tube:

Ordering code:(See page 11) T5 Example: MPF 030 1 A H1 A10 HB/T5

MPF 750 1 A K1 A10 HB/T5

Please note, when the T5 option is required, fill the ordering,code with H or K instead of G or F port option (see the example below).Indicator option is not available when the filler plug is fitted (except for MPF 184).

Example: length H = 300 mm. Visual indicator.Filter code: MPF 100 1 - AG1 A10HB/30 – Indicator code: V1

NOTES:

– When extension tube is ordered, indicator must be ordered separately

– Extension tube lengths have variable sizesmultiple of 10 mm.

Filler plug:

Special application filters on request

Ordering code and lengthCODE LENGTH

XX “H” in mm.

10 100

11 110

12 120

… …

99 990

Filler plug.Thread M 30x1,5

Page 11: Pagine int.MPF italiano

11

MP Filtri - Filtration products will only be guaranteed if original MP Filtrireplacement elements and spares are used

Data held in this publication is given only for indicative purposes. MP Filtri reserves to introducemodifications to describe items for technical or commercial reasons. Copyright reserved.

N 3 bar (P/M series)H 10 bar (A series, only)

T With plug (std)V1 VisualVR Visual (MPF 184 Series only)ER Electrical: N.O. contactsEC Electrical: N.C. contactsT5 Filler plug (see page 10)XX Exstension tube (see page 10)

P10 Resin-impregnated paper Bx ≥ 2P25

M25M60 Square wire meshM90

A03A06 Inorganic microfibre Bx ≥ 200A10A25

A Nitrile (Buna-N)V Viton

G1

G2

G3

G4

G5

G6

G7

G8

G9

F1

F2

F3

F4

1/2” BSP

1/2” NPT

SAE 8

1/2” BSP

3/4” BSP

1” BSP

1/2” NPT

3/4” NPT

1” NPT

SAE 8

SAE 12

SAE 16

1 1/4” BSP

1 1/4” NPT

SAE 20

1 1/4” BSP

1 1/2” BSP

2” BSP

1 1/4” NPT

1 1/2” NPT

2” NPT

SAE 20

SAE 24

SAE 32

2” BSP

2” NPT

SAE 32

1 1/4” BSP

2 Ports1 1/4” BSP

1 1/4” NPT

2 Ports1 1/4” NPT

SAE 20

2 PortsSAE 20

1 1/2” SAE3000 PSI/M

2 SAE3000 PSI/M

1 1/2” SAE3000 PSI/UNC

2 SAE3000 PSI/UNC

2x1 1/2” SAE3000 PSI/M

2x1 1/2” SAE3000 PSI/UNC

MPF 030 = 1MPF 100 = 1,2,3MPF 180-184 = 1,2MPF 400 = 1,2,3MPF 750 = 1

O r d e r i n g i n f o r m a t i o n

R e p l a c e m e n t e l e m e n t

MPF

MF

030100180184400750

(use MF 180 filter element code)

Nominal sizes

Bowl lengths

Ports option

Seals

Filter elements N series

Type MPF 030 MPF 100 MPF 180 MPF 184 MPF 400 MPF 750

Filter elements H series

Bypass valveB Bypass 1.75 bar

Seals (Filter elements)B Nitrile (Buna - N) V Viton

Filter condition indicator

Collapse pressure series

Page 12: Pagine int.MPF italiano