6
JOB NO. DRAWN BY: CHECKED BY: DATE: SCALE: REV: DESC: DATE: PROJECT TITLE FY2019 NJDCA - SMALL CITIES PROGRAM RENOVATIONS TO THE OLD LIBRARY 6301 OCEAN AVENUE WILDWOOD CREST, NJ NJ AUTH. NO. 24GA28120100 CONSULTING ENGINEERS, LLC NJ LIC. NO. 24GE04051000 PROFESSIONAL ENGINEER JEFFREY A. MOORE Tel: (609) 268-0500 Fax: (609) 268-5050 457 Oakshade Road, Shamong, NJ 08088 MOORE 10/08/2021 MECHANICAL COVERSHEET M000

P400 (24X36)

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: P400 (24X36)

JOB NO.

DRAWN BY:

CHECKED BY:

DATE:

SCALE:

REV: DESC: DATE:

PR

OJE

CT

TIT

LE

FY

20

19

N

JD

CA

- S

MA

LL

C

IT

IE

S P

RO

GR

AM

RE

NO

VA

TIO

NS

T

O T

HE

O

LD

L

IB

RA

RY

63

01

O

CE

AN

A

VE

NU

E

WIL

DW

OO

D C

RE

ST

, N

J

NJ A

UT

H. N

O. 24G

A28120100

CO

NS

UL

TIN

G E

NG

IN

EE

RS

, L

LC

NJ LIC

. N

O. 24G

E04051000

PR

OF

ES

SIO

NA

L E

NG

IN

EE

R

JE

FF

RE

Y A

. M

OO

RE

Tel: (609) 268-0500 F

ax: (609) 268-5050

457 O

akshade R

oad, S

ham

ong, N

J 08088

MOORE

10/08/2021

ME

CH

AN

IC

AL C

OV

ER

SH

EE

T

M000

AutoCAD SHX Text
CONTRACTOR SHALL CHECK & VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO STARTING CONSTRUCTION.
AutoCAD SHX Text
21093
AutoCAD SHX Text
10/8/2021
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
10/8/21
AutoCAD SHX Text
PERMIT
AutoCAD SHX Text
ZCR/GJF
AutoCAD SHX Text
SLC
AutoCAD SHX Text
FIRE DAMPER (WALL) W/ ACCESS DOOR
AutoCAD SHX Text
DIRECTION OF SUPPLY AIR
AutoCAD SHX Text
DIRECTION OF RETURN AIR
AutoCAD SHX Text
FIRE DAMPER (CEILING) W/ ACCESS DOOR
AutoCAD SHX Text
VOLUME DAMPER
AutoCAD SHX Text
CEILING DIFFUSER
AutoCAD SHX Text
RETURN/EXHAUST GRILLE
AutoCAD SHX Text
SUPPLY AIR DUCT UP
AutoCAD SHX Text
RETURN AIR DUCT UP
AutoCAD SHX Text
SUPPLY AIR DUCT DN
AutoCAD SHX Text
RETURN AIR DUCT DN
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
R
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
OR CFM
AutoCAD SHX Text
BDD
AutoCAD SHX Text
(NOT ALL SYMBOLS ARE NECESSARILY USED ON THIS PROJECT)
AutoCAD SHX Text
SINGLE LINE DUCTWORK OR EQUIPMENT - EXISTING
AutoCAD SHX Text
SINGLE LINE DUCTWORK OR EQUIPMENT - NEW
AutoCAD SHX Text
AAV
AutoCAD SHX Text
AUTOMATIC AIR VENT
AutoCAD SHX Text
HEAT EXCHANGER
AutoCAD SHX Text
HX
AutoCAD SHX Text
HEATING AND VENTILATING
AutoCAD SHX Text
HV
AutoCAD SHX Text
HOUR
AutoCAD SHX Text
HR
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
HT
AutoCAD SHX Text
GALLONS PER MINUTE
AutoCAD SHX Text
GPM
AutoCAD SHX Text
GALLONS PER HOUR
AutoCAD SHX Text
GPH
AutoCAD SHX Text
GALLON
AutoCAD SHX Text
GAL
AutoCAD SHX Text
FEET PER MINUTE
AutoCAD SHX Text
FPM
AutoCAD SHX Text
FULL LOAD AMPERES
AutoCAD SHX Text
FLA
AutoCAD SHX Text
FINISHED FLOOR
AutoCAD SHX Text
FIN FL
AutoCAD SHX Text
FIRE DAMPER
AutoCAD SHX Text
FD
AutoCAD SHX Text
FLEXIBLE CONNECTION
AutoCAD SHX Text
FC
AutoCAD SHX Text
FREE AREA (SQ.FT.)
AutoCAD SHX Text
FA
AutoCAD SHX Text
DEGREES FAHRENHEIT
AutoCAD SHX Text
%%DF
AutoCAD SHX Text
EXHAUST
AutoCAD SHX Text
EXH
AutoCAD SHX Text
ENTERING WATER TEMPERATURE
AutoCAD SHX Text
EWT
AutoCAD SHX Text
ENTERING WET BULB
AutoCAD SHX Text
EWB
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
EL
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
EF
AutoCAD SHX Text
ENTERING DRY BULB TEMPERATURE
AutoCAD SHX Text
EDB
AutoCAD SHX Text
ENTERING AIR TEMPERATURE
AutoCAD SHX Text
EAT
AutoCAD SHX Text
DIRECT EXPANSION
AutoCAD SHX Text
DX
AutoCAD SHX Text
DAMPER
AutoCAD SHX Text
DMPR
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
DIAM
AutoCAD SHX Text
DRY BULB
AutoCAD SHX Text
DB
AutoCAD SHX Text
CONSTANT VOLUME
AutoCAD SHX Text
CV
AutoCAD SHX Text
CABINET UNIT HEATER
AutoCAD SHX Text
CUH
AutoCAD SHX Text
CEILING REGISTER
AutoCAD SHX Text
CR
AutoCAD SHX Text
CONDENSATE
AutoCAD SHX Text
COND
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CLG
AutoCAD SHX Text
CEILING GRILLE
AutoCAD SHX Text
CG
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
CFM
AutoCAD SHX Text
CEILING DIFFUSER
AutoCAD SHX Text
CD
AutoCAD SHX Text
BTU PER HOUR
AutoCAD SHX Text
BTUH
AutoCAD SHX Text
BRITISH THERMAL UNIT
AutoCAD SHX Text
BTU
AutoCAD SHX Text
BOTTOM THROAT
AutoCAD SHX Text
BT
AutoCAD SHX Text
BOTTOM REGISTER
AutoCAD SHX Text
BR
AutoCAD SHX Text
BRAKE HORSEPOWER
AutoCAD SHX Text
BHP
AutoCAD SHX Text
BLOWER COIL UNIT
AutoCAD SHX Text
BCU
AutoCAD SHX Text
AIR HANDLING UNIT
AutoCAD SHX Text
AHU
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ACCESS DOOR
AutoCAD SHX Text
AD
AutoCAD SHX Text
AIR CONDITIONING UNIT
AutoCAD SHX Text
ACU
AutoCAD SHX Text
AIR CONDITIONING
AutoCAD SHX Text
AC
AutoCAD SHX Text
POINT OF DISCONNECTION
AutoCAD SHX Text
POINT OF CONNECTION
AutoCAD SHX Text
SQUARE FEET
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
CENTER LINE
AutoCAD SHX Text
DROP IN DUCTWORK (IN DIRECTION OF AIR FLOW)
AutoCAD SHX Text
RISE IN DUCTWORK (IN DIRECTION OF AIR FLOW)
AutoCAD SHX Text
AUTOMATIC SMOKE DAMPER
AutoCAD SHX Text
MOTORIZED DAMPER
AutoCAD SHX Text
BACK DRAFT DAMPER
AutoCAD SHX Text
DUCTWORK WITH ACOUSTIC LINING
AutoCAD SHX Text
SMK
AutoCAD SHX Text
c
AutoCAD SHX Text
%%C
AutoCAD SHX Text
(ER)
AutoCAD SHX Text
(ERR)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
EXISTING TO BE REMOVED & RELOCATED
AutoCAD SHX Text
EXISTING TO BE REMOVED
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text
FLEXIBLE DUCT
AutoCAD SHX Text
TRANSITION
AutoCAD SHX Text
EXTERNAL STATIC PRESSURE
AutoCAD SHX Text
ESP
AutoCAD SHX Text
SD
AutoCAD SHX Text
SMOKE DAMPER
AutoCAD SHX Text
SA
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
RLA
AutoCAD SHX Text
RUNNING LOAD AMPS
AutoCAD SHX Text
VFD
AutoCAD SHX Text
VARIABLE FREQUENCY DRIVE
AutoCAD SHX Text
SF
AutoCAD SHX Text
SUPPLY FAN
AutoCAD SHX Text
LD
AutoCAD SHX Text
LINEAR DIFFUSER
AutoCAD SHX Text
LF
AutoCAD SHX Text
LINEAR FEET
AutoCAD SHX Text
W.G.
AutoCAD SHX Text
WET BULB
AutoCAD SHX Text
WB
AutoCAD SHX Text
WITH
AutoCAD SHX Text
W/
AutoCAD SHX Text
WIDTH
AutoCAD SHX Text
W
AutoCAD SHX Text
VARIABLE INLET VANES
AutoCAD SHX Text
VIV
AutoCAD SHX Text
VARIABLE AIR VOLUME
AutoCAD SHX Text
VAV
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
UH
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
TYP
AutoCAD SHX Text
TOP REGISTER
AutoCAD SHX Text
TR
AutoCAD SHX Text
TRANSFER GRILLE
AutoCAD SHX Text
TG
AutoCAD SHX Text
TEMPERATURE
AutoCAD SHX Text
TEMP
AutoCAD SHX Text
TOTAL DYNAMIC HEAD
AutoCAD SHX Text
TDH
AutoCAD SHX Text
SQUARE FEET
AutoCAD SHX Text
SQFT
AutoCAD SHX Text
STATIC PRESSURE
AutoCAD SHX Text
SP
AutoCAD SHX Text
REVOLUTIONS PER MINUTE
AutoCAD SHX Text
RPM
AutoCAD SHX Text
RELATIVE HUMIDITY
AutoCAD SHX Text
RH
AutoCAD SHX Text
RETURN FAN
AutoCAD SHX Text
RF
AutoCAD SHX Text
RETURN AIR
AutoCAD SHX Text
RA
AutoCAD SHX Text
PSI GAUGE
AutoCAD SHX Text
PSIG
AutoCAD SHX Text
PSI ABSOLUTE
AutoCAD SHX Text
PSIA
AutoCAD SHX Text
POUNDS PER SQUARE INCH
AutoCAD SHX Text
PSI
AutoCAD SHX Text
OUTSIDE AIR INTAKE
AutoCAD SHX Text
OAI
AutoCAD SHX Text
OUTSIDE AIR
AutoCAD SHX Text
OA
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NORMALLY OPEN
AutoCAD SHX Text
NO
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NORMALLY CLOSED
AutoCAD SHX Text
NC
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
MIN
AutoCAD SHX Text
MECHANICAL EQUIPMENT ROOM
AutoCAD SHX Text
MER
AutoCAD SHX Text
THOUSAND BTU PER HOUR
AutoCAD SHX Text
MBH
AutoCAD SHX Text
LEAVING WATER TEMPERATURE
AutoCAD SHX Text
LWT
AutoCAD SHX Text
LEAVING WET BULB TEMPERATURE
AutoCAD SHX Text
LWB
AutoCAD SHX Text
LEAVING AIR TEMPERATURE
AutoCAD SHX Text
LAT
AutoCAD SHX Text
INCH OR INCHES
AutoCAD SHX Text
IN.
AutoCAD SHX Text
(RE)
AutoCAD SHX Text
RELOCATED EXISTING
AutoCAD SHX Text
(RRO)
AutoCAD SHX Text
EXISTING TO BE REMOVED
AutoCAD SHX Text
AND RETURN TO OWNER
AutoCAD SHX Text
REHEAT COIL
AutoCAD SHX Text
RHC
AutoCAD SHX Text
OED
AutoCAD SHX Text
OPEN END DUCT
AutoCAD SHX Text
(N)
AutoCAD SHX Text
NEW
AutoCAD SHX Text
CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING OR EXCEEDING WALL/CEILING/FLOOR ASSEMBLY RATINGS FOR ALL PENETRATIONS. CONTRACTOR SHALL VERIFY LOCATION AND RATING OF ALL FIRE ASSEMBLIES AND PROVIDE INTUMESCENT COLLARS AT ALL PENETRATIONS AND FIRE RATED CAULKING AS REQUIRED.
AutoCAD SHX Text
GENERAL FIRESTOPPING NOTE
AutoCAD SHX Text
U
AutoCAD SHX Text
D
AutoCAD SHX Text
S
AutoCAD SHX Text
FLEXIBLE CONNECTOR
AutoCAD SHX Text
"Y" TYPE STRAINER W/BLOW OFF VALVE
AutoCAD SHX Text
PUMP
AutoCAD SHX Text
PRESSURE GAUGE
AutoCAD SHX Text
THERMOMETER AND WELL
AutoCAD SHX Text
THREE-WAY AUTOMATIC CONTROL VALVE
AutoCAD SHX Text
AUTOMATIC CONTROL VALVE
AutoCAD SHX Text
PLUG VALVE (TYPE AS NOTED)
AutoCAD SHX Text
CALIBRATED BALANCING VALVE
AutoCAD SHX Text
SQUARE HEAD COCK
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
BUTTERFLY VALVE
AutoCAD SHX Text
SILENT CHECK VALVE
AutoCAD SHX Text
CHECK VALVE, SWING OR LIFT
AutoCAD SHX Text
LOCK SHIELD VALVE
AutoCAD SHX Text
DRAIN VALVE
AutoCAD SHX Text
NEEDLE VALVE COCK
AutoCAD SHX Text
ANGLE GLOBE VALVE
AutoCAD SHX Text
GLOBE VALVE
AutoCAD SHX Text
ANGLE VALVE
AutoCAD SHX Text
GATE OR SHUTOFF VALVE (AS NOTED)
AutoCAD SHX Text
PIPE ANCHOR
AutoCAD SHX Text
PIPE ALIGNMENT GUIDE
AutoCAD SHX Text
PIPE EXPANSION JOINT
AutoCAD SHX Text
EXPANSION LOOP
AutoCAD SHX Text
FLANGED END
AutoCAD SHX Text
FLANGED CONNECTION
AutoCAD SHX Text
ECCENTRIC REDUCER - FLAT TOP
AutoCAD SHX Text
ECCENTRIC REDUCER - FLAT BOTTOM
AutoCAD SHX Text
CONCENTRIC REDUCER
AutoCAD SHX Text
UNION
AutoCAD SHX Text
PITCH DOWN IN DIRECTION OF FLOW
AutoCAD SHX Text
PITCH UP IN DIRECTION OF FLOW
AutoCAD SHX Text
PIPE RISE
AutoCAD SHX Text
PIPE DROP
AutoCAD SHX Text
(NOT ALL SYMBOLS ARE NECESSARILY USED ON THIS PROJECT)
AutoCAD SHX Text
EXHAUST AIR
AutoCAD SHX Text
EA
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
DN
AutoCAD SHX Text
RTU
AutoCAD SHX Text
ROOFTOP AIR HANDLING UNIT
AutoCAD SHX Text
HORSEPOWER
AutoCAD SHX Text
HP
AutoCAD SHX Text
VOLUME DAMPER
AutoCAD SHX Text
VD
AutoCAD SHX Text
MOTOR OPERATED DAMPER
AutoCAD SHX Text
MOD
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
T-STAT
AutoCAD SHX Text
WATER GAUGE
AutoCAD SHX Text
COMBINATION FIRE & SMOKE DAMPER W/ ACCESS DOOR
AutoCAD SHX Text
F/S
AutoCAD SHX Text
ENERGY MANAGEMENT SYSTEM
AutoCAD SHX Text
EMS
AutoCAD SHX Text
EXHAUST GRILLE
AutoCAD SHX Text
EG
AutoCAD SHX Text
EXHAUST REGISTER
AutoCAD SHX Text
ER
AutoCAD SHX Text
DIRECT DIGITAL CONTROL
AutoCAD SHX Text
DDC
AutoCAD SHX Text
RETURN GRILLE
AutoCAD SHX Text
RG
AutoCAD SHX Text
RETURN REGISTER
AutoCAD SHX Text
RR
AutoCAD SHX Text
WMS
AutoCAD SHX Text
WIRE MESH SCREEN
AutoCAD SHX Text
WH
AutoCAD SHX Text
WATER HEATER
AutoCAD SHX Text
WATER COLUMN
AutoCAD SHX Text
W.C.
AutoCAD SHX Text
%%UHVAC ABBREVIATIONS
AutoCAD SHX Text
%%UHVAC BASIC DUCTWORK SYMBOLS
AutoCAD SHX Text
%%UHVAC BASIC PIPING SYMBOLS
AutoCAD SHX Text
HERTZ (FREQUENCY)
AutoCAD SHX Text
HZ
AutoCAD SHX Text
SPECIFICATION
AutoCAD SHX Text
SPEC
AutoCAD SHX Text
TRANSITION
AutoCAD SHX Text
TRANS
AutoCAD SHX Text
1. PRIOR TO SUBMITTING A BID THE CONTRACTOR SHALL EXAMINE PRIOR TO SUBMITTING A BID THE CONTRACTOR SHALL EXAMINE ALL DRAWINGS AND SPECIFICATIONS AND VISIT THE SITE TO BECOME ACQUAINTED WITH THE CONSTRUCTION AND THE EXTENT OF THE WORK. NO EQUIPMENT OR MATERIAL IS TO BE ORDERED OR FABRICATED PRIOR TO FIELD VERIFICATION OF ALL MEASUREMENTS, CLEARANCES, POTENTIAL CONFLICTS WITH EXISTING CONDITIONS OR THAT OF OTHER TRADES ON THE JOB. 2. CONTRACTOR SHALL PROVIDE ALL MATERIALS AND EQUIPMENT CONTRACTOR SHALL PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE, WHETHER SPECIFIED OR IMPLIED. 3. CONTRACTOR SHALL VISIT THE JOB PRIOR TO SUBMITTING A CONTRACTOR SHALL VISIT THE JOB PRIOR TO SUBMITTING A BID. 4. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST APPLICABLE INTERNATIONAL BUILDING CODE, MECHANICAL CODE, FUEL GAS CODE, PLUMBING CODE, NEC CODE AND ALL OTHER STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. 5. CONTRACTOR SHALL GIVE ALL NOTICES, OBTAIN AND PAY FOR CONTRACTOR SHALL GIVE ALL NOTICES, OBTAIN AND PAY FOR ALL PERMITS, DEPOSITS AND FEES NECESSARY. 6. DO NOT SCALE THE DRAWINGS FOR EXACT DIMENSIONS. THE DO NOT SCALE THE DRAWINGS FOR EXACT DIMENSIONS. THE DESIGN DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL LAYOUT AND CONNECTIONS. CONTRACTOR SHALL VERIFY ALL CONDITIONS, DIMENSIONS, ETC. AT THE JOB SITE. 7. CONTRACTOR SHALL REVIEW THE WORK OF OTHER TRADES TO CONTRACTOR SHALL REVIEW THE WORK OF OTHER TRADES TO PREVENT INTERFERENCE BETWEEN BEAMS, STRUCTURES, PIPING, LIGHTING FIXTURES ETC. BEFORE PROCEEDING WITH NEW WORK. 8. CONTRACTOR SHALL GUARANTEE THE ENTIRE JOB AGAINST CONTRACTOR SHALL GUARANTEE THE ENTIRE JOB AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE. THIS GUARANTEE SHALL BE BINDING REGARDLESS OF MANUFACTURER'S GUARANTEE AND CONTRACTOR SHALL REMOVE AND REPLACE ALL DEFECTIVE MATERIAL REGARDLESS OF CAUSE (EXCEPT FOR DEFECTS TRACEABLE TO IMPROPER MAINTENANCE OR MALICIOUS DESTRUCTION OCCURRING AFTER THE SYSTEM HAS BEEN TURNED OVER). 9. ALL MATERIALS USED ANYWHERE IN THE WORK SHALL HAVE ALL MATERIALS USED ANYWHERE IN THE WORK SHALL HAVE NFPA RATING AS FOLLOWS: A. FLAME SPREAD- NOT OVER 25 FLAME SPREAD- NOT OVER 25 B. SMOKE DEVELOPED- NOT OVER 50 SMOKE DEVELOPED- NOT OVER 50 C. FUEL CONTRIBUTED- NOT OVER 25 FUEL CONTRIBUTED- NOT OVER 25 ALL MATERIALS SHALL BE "SELF-EXTINGUISHING" 10. CONTRACTOR SHALL SUBMIT 1/4" SCALE SHEET METAL SHOP CONTRACTOR SHALL SUBMIT 1/4" SCALE SHEET METAL SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 11. SUBMIT TO THE ARCHITECT FOR APPROVAL, SPECIFICATION SUBMIT TO THE ARCHITECT FOR APPROVAL, SPECIFICATION SHEETS OF ALL EQUIPMENT SUPPLIED OR INSTALLED, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: A. AIR CONDITIONING UNITS AIR CONDITIONING UNITS B. GRILLES, REGISTERS, AND DIFFUSERS GRILLES, REGISTERS, AND DIFFUSERS C. CONTROLS CONTROLS D. PIPING PIPING E. INSULATION INSULATION F. FANS FANS 12. ALL MECHANICAL EQUIPMENT AND APPLIANCES INSTALLED SHALL ALL MECHANICAL EQUIPMENT AND APPLIANCES INSTALLED SHALL BEAR THE LABEL OF AN APPROVED AGENCY. 13. EQUIPMENT AND MATERIALS ARE SPECIFIED TO ESTABLISH A EQUIPMENT AND MATERIALS ARE SPECIFIED TO ESTABLISH A STANDARD OF QUALITY. ALL MATERIALS AND EQUIPMENT USED FOR THIS CONTRACT SHALL BE NEW AND UNUSED AND OF THE LATEST MODEL OR DESIGN AVAILABLE. 14. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT INSULATION IS APPLIED. 15. CONTRACTOR SHALL PROVIDE 1-INCH THICK (R-5) FOAM CONTRACTOR SHALL PROVIDE 1-INCH THICK (R-5) FOAM BOARD INSULATION PAINTED TO MATCH THE ROOM'S FINISH FOR ALL THERMOSTAT'S MOUNTED ON MASONRY WALLS. 16. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL THE CONTRACTOR SHALL FURNISH AND INSTALL ALL STRUCTURAL STEEL, SUPPORTS, BRACES, HANGERS, ETC., REQUIRED FOR HIS CONTRACT UNLESS OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT SUPPORT LOCATION AND INSTALLATION WITH ROOFING AND STRUCTURAL CONTRACTORS. 17. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR. 18. MAXIMUM ALLOWABLE LENGTH FOR FLEXIBLE DUCT IS SIX (6') MAXIMUM ALLOWABLE LENGTH FOR FLEXIBLE DUCT IS SIX (6') FEET. 19. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING MECHANICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING AND PATCHING EITHER ENGAGING HIS OWN GENERAL SUBCONTRACTOR OR ONE QUALIFIED BY THE OWNER. 20. CONTRACTOR SHALL INFORM THE ENGINEER OF ANY QUESTIONS CONTRACTOR SHALL INFORM THE ENGINEER OF ANY QUESTIONS OR DISCREPANCIES PRIOR TO PRECURSOR AND/OR FABRICATION OF ANY MATERIALS AND INSTALLATION. 21. INSTALL ALL EQUIPMENT IN ACCORDANCE TO THE INSTALL ALL EQUIPMENT IN ACCORDANCE TO THE MANUFACTURER'S WRITTEN GUIDELINES. 22. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONNECTIONS, SUPPORTS, TERMINATIONS & ACCESSORIES ASSOCIATED WITH AIR HANDLING UNITS, FANS, ETC. 23. MECHANICAL CONTRACTOR SHALL COORDINATE WITH ELECTRICAL MECHANICAL CONTRACTOR SHALL COORDINATE WITH ELECTRICAL CONTRACTOR WHO WILL PROVIDE POWER WIRING TO ALL MECHANICAL EQUIPMENT. MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL AND INTERLOCK WIRING AND ALL THERMOSTATS AND ACCESSORIES. 24. SUPPORT ALL EQUIPMENT, PIPING AND DUCTWORK WITH SUPPORT ALL EQUIPMENT, PIPING AND DUCTWORK WITH VIBRATION ISOLATION HANGERS AS REQUIRED TO PROVIDE A VIBRATION FREE INSTALLATION. 25. ALL EXTERIOR WALL OPENINGS SHALL BE SLEEVED, PROPERLY ALL EXTERIOR WALL OPENINGS SHALL BE SLEEVED, PROPERLY CAULKED AND SEALED WITH A HIGH QUALITY SEALANT TO PREVENT INFILTRATION OF MOISTURE AND OUTSIDE AIR. 26. PROVIDE VOLUME DAMPERS AT ALL DUCT BRANCHES AND PROVIDE VOLUME DAMPERS AT ALL DUCT BRANCHES AND RUNOUTS. PROVIDE OPPOSED BLADE VOLUME DAMPERS AT ALL REGISTERS, GRILLES AND DIFFUSER NECKS IN SUPPLY, RETURN AND EXHAUST DUCTWORK WHETHER SHOWN ON DRAWINGS OR NOT. 27. PROVIDE AT MINIMUM 10 GAUGE STEEL SLEEVES FOR ALL DUCT PROVIDE AT MINIMUM 10 GAUGE STEEL SLEEVES FOR ALL DUCT PENETRATIONS THROUGH FIRE WALLS, FLOORS AND PARTITIONS. PROVIDE PIPE SLEEVES FOR ALL MECHANICAL PIPING PENETRATING THROUGH FIRE WALLS, FLOORS AND PARTITIONS. SEAL ALL ANNULAR SPACE BETWEEN SLEEVES AND DUCTWORK OR PIPING WITH A FIRE BARRIER MATERIAL. 28. PROVIDE FLEXIBLE CONNECTIONS ON ALL DUCTS AND PIPING PROVIDE FLEXIBLE CONNECTIONS ON ALL DUCTS AND PIPING CONNECTIONS TO ANY MOTOR DRIVEN MECHANICAL EQUIPMENT (I.E. FANS, AIR HANDLERS, PUMPS, ETC.) INSTALL FLEXIBLE COPPER GROUNDING STRAPS ACROSS ALL FLEXIBLE CONNECTIONS. 29. THE INSIDE OF ALL DUCTWORK VISIBLE THROUGH A GRILLE OR THE INSIDE OF ALL DUCTWORK VISIBLE THROUGH A GRILLE OR DIFFUSER SHALL BE PAINTED FLAT BLACK. 30. ACCESS PANELS SHALL BE PROVIDED TO SERVICE ALL VALVES, ACCESS PANELS SHALL BE PROVIDED TO SERVICE ALL VALVES, DAMPERS, HEATERS, CONCEALED MECHANICAL EQUIPMENT, TRAPS, CLEANOUTS AND DISCHARGE SIDE OF ELECTRIC HEATERS. 31. FINAL LOCATIONS FOR MOUNTING ALL THERMOSTATS SHALL BE FINAL LOCATIONS FOR MOUNTING ALL THERMOSTATS SHALL BE COORDINATED WITH THE ENGINEER PRIOR TO INSTALLING ANY CONTROL WORK. ALL COMMON AREA THERMOSTATS SHALL BE EQUIPPED WITH A LOCKING COVERS. MOUNT ALL THERMOSTATS TO COMPLY WITH ADA REQUIREMENTS. 32. UPON COMPLETION OF THE WORK, REMOVE ALL EXCESS UPON COMPLETION OF THE WORK, REMOVE ALL EXCESS MATERIAL, DEBRIS, TOOLS AND EQUIPMENT FROM THE SITE, AND LEAVE THE PREMISES IN A BROOM CLEAN CONDITION. 33. CONTRACTOR SHALL PROVIDE THREE (3) COMPLETE SETS OF CONTRACTOR SHALL PROVIDE THREE (3) COMPLETE SETS OF BOUND OPERATING AND MAINTENANCE INSTRUCTIONS. CONTRACTOR SHALL INSTRUCT THE OWNER OR HIS AGENT WITH REGARD TO THE PROPER USE OF THE SYSTEM UNTIL SUCH INSTRUCTION IS COMPLETE TO THE OWNER'S SATISFACTION. 34. TESTING, ADJUSTING, AND BALANCING AGENCY SHALL BE A TESTING, ADJUSTING, AND BALANCING AGENCY SHALL BE A MEMBER OF THE ASSOCIATED AIR BALANCE COUNCIL (AABC) OR THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB). TESTING, ADJUSTING, AND BALANCING SHALL BE PERFORMED IN ACCORDANCE WITH THE AABC OR NEBB STANDARDS. 35. CONTRACTOR SHALL ENSURE THAT ALL MECHANICAL DEVICES CONTRACTOR SHALL ENSURE THAT ALL MECHANICAL DEVICES WILL BE INSTALLED IN LOCATIONS WHICH AFFORD ACCESSIBILITY FOR MAINTENANCE AND REPAIR. COORDINATE INSTALLATION AMONG ALL TRADES TO AVOID INTERFERENCES AND LOCATE EQUIPMENT TO PROVIDE CLEARANCES WHICH EXCEED THOSE RECOMMENDED BY THE EQUIPMENT MANUFACTURER. 36. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFETY OF EXISTING STRUCTURE. 37. THERMOSTAT WIRING SHALL BE INSTALLED IN CONCEALED THERMOSTAT WIRING SHALL BE INSTALLED IN CONCEALED SPACE, WALL OR CHASE - COORDINATE WITH THE OWNER REPRESENTATIVE. 38. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION SCHEDULING AND ASSOCIATED HOISTING STAGING AND ERECTING OF MATERIALS. ALL ELEMENTS OF THE EXISTING PROPERTY SHALL BE PROTECTED AGAINST DAMAGE RESULTING FROM THESE ACTIVITIES. 39. THE LOCATION OF EXISTING SYSTEMS AND SYSTEM THE LOCATION OF EXISTING SYSTEMS AND SYSTEM COMPONENTS WAS OBTAINED THROUGH EXISTING DRAWINGS AND FIELD SURVEYS. ONLY SYSTEM ELEMENTS THAT WERE CLEARLY VISIBLE HAVE BEEN IDENTIFIED. LOCATIONS AND SIZES OF EXISTING SYSTEMS MUST BE FIELD VERIFIED BY THE CONTRACTOR, PRIOR TO THE REMOVAL OF ANY EXISTING SYSTEM COMPONENTS AND CONNECTING NEW SYSTEMS TO EXISTING. 40. THESE DRAWINGS HAVE BEEN MADE BASED ON A VISUAL THESE DRAWINGS HAVE BEEN MADE BASED ON A VISUAL INSPECTION OF THE EXISTING SURFACES. SOME ASSUMPTIONS HAVE BEEN MADE AS TO ACTUAL CONSTRUCTION, MATERIALS, AND METHODS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL ACTUAL FIELD CONDITIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES, CONFLICTS, AND UNFORESEEN CONDITIONS. IN ADDITION, THESE DRAWINGS ASSUME THAT ALL EXISTING MATERIALS ARE IN GOOD STRUCTURAL SHAPE, GOOD WORKING ORDER, AND MEET ALL APPLICABLE CODES. THE GENERAL CONTRACTOR IS RESPONSIBLE TO INSPECT ALL THE EXISTING ELEMENTS OF THE STRUCTURE AND REPORT TO THE CLIENT AND TO THE ARCHITECT OF ANY SIGNS OF POTENTIAL PROBLEMS WITH THE STRUCTURE INCLUDING, BUT NOT LIMITED TO, WOOD DECAYING ORGANISMS, WATER PENETRATION, STRUCTURAL FRACTURES, STRESSED SURFACES, BRICK AND MASONRY WEAKENING AND WEAK STRUCTURAL CONNECTIONS. 41. ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO PERFORM STARTUP SERVICES. COMPLETE INSTALLATION AND STARTUP CHECKS SHALL BE ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS AND STARTUP REPORTS SHALL BE PROVIDED TO ARCHITECT/ENGINEER FOLLOWING COMPLETION. STARTUP SHALL BE PROVIDED FOR ALL EQUIPMENT SUPPLIED OR INSTALLED, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: A. AIR CONDITIONING UNITS AIR CONDITIONING UNITS B. HEATERS HEATERS C. PUMPS PUMPS D. FANS FANS E. BOILERS BOILERS F. CHILLERS CHILLERS G. CONDENSERS & HEAT PUMPS CONDENSERS & HEAT PUMPS H. CONTROLS CONTROLS
AutoCAD SHX Text
%%UMECHANICAL NOTES
AutoCAD SHX Text
VD
AutoCAD SHX Text
FAN COIL UNIT
AutoCAD SHX Text
FCU
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
HUMIDISTAT
AutoCAD SHX Text
DOOR UNDERCUT
AutoCAD SHX Text
UC
AutoCAD SHX Text
SHEET NO. WHERE DETAIL IS SHOWN
AutoCAD SHX Text
DETAIL DESIGNATION
AutoCAD SHX Text
SHEET NO. WHERE SECTION IS SHOWN
AutoCAD SHX Text
SECTION DESIGNATION
AutoCAD SHX Text
DUCT SMOKE DETECTOR
AutoCAD SHX Text
T
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
ROUND BRANCH TAKE-OFF w/SPIN FITTING
AutoCAD SHX Text
%%C"
AutoCAD SHX Text
%%C"
AutoCAD SHX Text
DUCT ELBOW DN
AutoCAD SHX Text
TEE-ON-TAPER (DUST COLLECTION ONLY)
AutoCAD SHX Text
DUCT ELBOW UP
AutoCAD SHX Text
ROUND BRANCH TAKE-OFF w/BELLMOUTH
AutoCAD SHX Text
BRANCH TAKE-OFF w/HEEL
AutoCAD SHX Text
6"
AutoCAD SHX Text
6"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
TEMPERATURE SENSOR
AutoCAD SHX Text
S
AutoCAD SHX Text
#
AutoCAD SHX Text
EQ
AutoCAD SHX Text
MECHANICAL EQUIPMENT TAG
AutoCAD SHX Text
RADIUS ELBOWS (REFER TO SPECIFICATIONS)
AutoCAD SHX Text
RADIUS ELBOWS OR SQUARE ELBOWS w/TURNING VANES
AutoCAD SHX Text
RADIUS ELBOWS (REFER TO SPECIFICATIONS)
AutoCAD SHX Text
PROPORTIONAL SPLIT OR EQUAL SPLIT.
AutoCAD SHX Text
(REFER TO SPECIFICATIONS)
AutoCAD SHX Text
PROPORTIONAL SPLIT OR EQUAL SPLIT.
AutoCAD SHX Text
STEAM TRAP
AutoCAD SHX Text
CARBON DIOXIDE SENSOR
AutoCAD SHX Text
C
AutoCAD SHX Text
CLEANOUT
AutoCAD SHX Text
CO
AutoCAD SHX Text
GRILLES, REGISTERS & DIFFUSERS
AutoCAD SHX Text
GRD
AutoCAD SHX Text
(NOT ALL ABBREVIATIONS ARE NECESSARILY USED ON THIS PROJECT)
AutoCAD SHX Text
SINGLE LINE DUCTWORK OR EQUIPMENT - DEMOLITION
AutoCAD SHX Text
M
AutoCAD SHX Text
M
Page 2: P400 (24X36)

JOB NO.

DRAWN BY:

CHECKED BY:

DATE:

SCALE:

REV: DESC: DATE:

PR

OJE

CT

TIT

LE

FY

20

19

N

JD

CA

- S

MA

LL

C

IT

IE

S P

RO

GR

AM

RE

NO

VA

TIO

NS

T

O T

HE

O

LD

L

IB

RA

RY

63

01

O

CE

AN

A

VE

NU

E

WIL

DW

OO

D C

RE

ST

, N

J

NJ A

UT

H. N

O. 24G

A28120100

CO

NS

UL

TIN

G E

NG

IN

EE

RS

, L

LC

NJ LIC

. N

O. 24G

E04051000

PR

OF

ES

SIO

NA

L E

NG

IN

EE

R

JE

FF

RE

Y A

. M

OO

RE

Tel: (609) 268-0500 F

ax: (609) 268-5050

457 O

akshade R

oad, S

ham

ong, N

J 08088

MOORE

10/08/2021

ME

CH

AN

IC

AL F

LO

OR

P

LA

N - D

EM

OLIT

IO

N

MD100

AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
(ER) WALL MOUNTED DUCTLESS SPLIT
AutoCAD SHX Text
(ER) WALL MOUNTED DUCTLESS SPLIT
AutoCAD SHX Text
(ER) CONDENSING UNIT (TYP. 2)
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
(ER) UNIT HEATER
AutoCAD SHX Text
3
AutoCAD SHX Text
(ER) BOILER
AutoCAD SHX Text
T
AutoCAD SHX Text
(ER) THERMOSTAT
AutoCAD SHX Text
T
AutoCAD SHX Text
(ER) THERMOSTAT
AutoCAD SHX Text
(E) ATTIC ACCESS DOOR
AutoCAD SHX Text
KEY NOTES DISCONNECT AND REMOVE ALL EXISTING AIR HANDLERS, FANS, DUCTWORK, PIPING, DUCT AND PIPING INSULATION, VALVES, GRD'S, HANGERS AND SUPPORTS IN THEIR ENTIRETY. DISCONNECT AND REMOVE EXISTING WALL MOUNTED DUCTLESS SPLITS, CONDENSING UNITS, HOUSEKEEPING PADS AND REFRIGERANT PIPING. DISCONNECT AND REMOVE EXISTING BOILER, ASSOCIATED FLUE, AND ALL OTHER ACCESSORIES.
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
DEMOLITION NOTES: 1. THE CONTRACTOR SHALL INCLUDE IN HIS PRICE ALL COSTS THE CONTRACTOR SHALL INCLUDE IN HIS PRICE ALL COSTS ASSOCIATED WITH REMOVALS AND RELOCATIONS OF HVAC WORK AS DESCRIBED ON THE DRAWINGS AND IN THE SPECIFICATIONS WITH ALLOWANCES FOR EXPECTED OR UNFORESEEN DIFFICULTIES WHEN CONCEALED WORK HAS BEEN OPENED. NO CLAIMS FOR ADDITIONAL WORK ASSOCIATED WITH DEMOLITION WILL BE ACCEPTED, EXCEPT IN CERTAIN CASES CONSIDERED JUSTIFIABLE BY THE OWNER/ENGINEER. 2. THE CONTRACTOR SHALL PERFORM DEMOLITION AND THE CONTRACTOR SHALL PERFORM DEMOLITION AND REMOVAL WORK WITH MINIMUM INTERFERENCE WITH FUNCTIONING HVAC SYSTEMS. ALL AFFECTED SYSTEMS SHALL BE RECONNECTED AND RESTORED. 3. DEMOLITION AND REMOVAL WORK SHALL BE PERFORMED IN DEMOLITION AND REMOVAL WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER. THE CONTRACTOR SHALL PATCH, REPAIR OR OTHERWISE RESTORE ANY DAMAGED INTERIOR OR EXTERIOR BUILDING SURFACE TO ITS ORIGINAL CONDITION. PATCH ALL EXISTING INTERIOR AND EXTERIOR WALLS, LEFT BY DEMOLITION, TO MATCH EXISTING. 4. THE CONTRACTOR SHALL REMOVE ALL DUCT & PIPING THE CONTRACTOR SHALL REMOVE ALL DUCT & PIPING SUPPORTS, ETC. FROM PARTITIONS THAT ARE TO BE REMOVED. WHERE THE REMOVAL OF THESE ITEMS DISRUPTS EXISTING PIPING THAT IS TO REMAIN, THE CONTRACTOR SHALL INSTALL AND PROVIDE BYPASS CONNECTIONS NECESSARY. 5. ALL PIPING WHICH BECOMES EXPOSED DURING THE ALL PIPING WHICH BECOMES EXPOSED DURING THE ALTERATION WORK SHALL BE REMOVED AND REROUTED CONCEALED BEHIND FINISHED SURFACES. 6. PORTIONS OF PIPING & DUCTWORK TO BE REMOVED OR PORTIONS OF PIPING & DUCTWORK TO BE REMOVED OR ABANDONED AS A RESULT OF DEMOLITION WORK, BUT WHICH ARE REQUIRED TO REMAIN ACTIVE, SHALL BE CUT AT CONVENIENT LOCATIONS, REROUTED AND RECONNECTED. 7. ALL EXISTING MATERIAL AND EQUIPMENT IN USABLE ALL EXISTING MATERIAL AND EQUIPMENT IN USABLE CONDITION, WHICH IS TO BE REMOVED UNDER THIS CONTRACT, SHALL BE DISPOSED OF BY THE MECHANICAL CONTRACTOR. 8. ARRANGE TO WORK CONTINUOUSLY, INCLUDING OVER TIME, ARRANGE TO WORK CONTINUOUSLY, INCLUDING OVER TIME, IF REQUIRED, TO ASSURE THAT SYSTEMS WILL BE SHUT DOWN ONLY DURING THE TIME ACTUALLY REQUIRED TO MAKE THE NECESSARY CONNECTIONS TO THE EXISTING SYSTEMS. 9. THE SHUTDOWN OF EXISTING BUILDING HVAC SERVICES THE SHUTDOWN OF EXISTING BUILDING HVAC SERVICES SHALL BE COORDINATED WITH THE OWNER. MAKE ARRANGEMENTS AT LEAST 5 BUSINESS DAYS PRIOR TO A SHUTDOWN. 10. CONTRACTOR SHALL COMPLY WITH ALL FEDERAL STATE & CONTRACTOR SHALL COMPLY WITH ALL FEDERAL STATE & LOCAL REQUIREMENTS REGARDING DISPOSAL OF REFRIGERANTS.
AutoCAD SHX Text
3
AutoCAD SHX Text
CONTRACTOR SHALL CHECK & VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO STARTING CONSTRUCTION.
AutoCAD SHX Text
21093
AutoCAD SHX Text
10/8/2021
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
10/8/21
AutoCAD SHX Text
PERMIT
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
01
AutoCAD SHX Text
MECHANICAL DEMOLITION PLAN
AutoCAD SHX Text
3/16" = 1'- 0"
AutoCAD SHX Text
SLC
AutoCAD SHX Text
ZCR/GJF
AutoCAD SHX Text
SLC
Page 3: P400 (24X36)

HISTORICAL107

STORAGE108

VESTIBULE109

SENIOR CENTER110

COMMON AREA112

ENVIRONMENTALOUTREACH

111

CONCESSIONS/CATERING113

NEW WM LAVS102

NEW MEN'S RM104

NEW J.C.105

BEACH STOR.114

ELECTRICAL106

NEW CORRIDOR101

VESTIBULE116

NEW WM TOILETRM103

MECHANICAL115

JOB NO.

DRAWN BY:

CHECKED BY:

DATE:

SCALE:

REV: DESC: DATE:

PR

OJE

CT

TIT

LE

FY

20

19

N

JD

CA

- S

MA

LL

C

IT

IE

S P

RO

GR

AM

RE

NO

VA

TIO

NS

T

O T

HE

O

LD

L

IB

RA

RY

63

01

O

CE

AN

A

VE

NU

E

WIL

DW

OO

D C

RE

ST

, N

J

NJ A

UT

H. N

O. 24G

A28120100

CO

NS

UL

TIN

G E

NG

IN

EE

RS

, L

LC

NJ LIC

. N

O. 24G

E04051000

PR

OF

ES

SIO

NA

L E

NG

IN

EE

R

JE

FF

RE

Y A

. M

OO

RE

Tel: (609) 268-0500 F

ax: (609) 268-5050

457 O

akshade R

oad, S

ham

ong, N

J 08088

MOORE

10/08/2021

ME

CH

AN

IC

AL F

LO

OR

P

LA

N

M100

AutoCAD SHX Text
DRAWING NOTES 1. DRAWINGS ARE DIAGRAMMATIC. PROVIDE ADDITIONAL DRAWINGS ARE DIAGRAMMATIC. PROVIDE ADDITIONAL OFFSETS, TRANSITIONS, ETC. AS REQUIRED TO AVOID INTERFERENCES ENCOUNTERED. 2. CONTRACTOR SHALL PROVIDE MANUFACTURER'S CONTRACTOR SHALL PROVIDE MANUFACTURER'S RECOMMENDED CLEARANCES AND ACCESS TO ALL EQUIPMENT. COORDINATE LOCATIONS WITH OTHER TRADES TO AVOID CONFLICTS. 3. SPACE ABOVE CEILING IS VERY LIMITED. COORDINATE WITH SPACE ABOVE CEILING IS VERY LIMITED. COORDINATE WITH ALL TRADES FOR DUCTWORK ROUTING PRIOR TO FABRICATION AND INSTALLATION. 4. ALL EXHAUST SHALL TERMINATE ON EXTERIOR A MINIMUM ALL EXHAUST SHALL TERMINATE ON EXTERIOR A MINIMUM OF 3 FEET FROM ALL OPERABLE WINDOWS AND OTHER OPENINGS TO BUILDING. 5. PROVIDE VOLUME DAMPERS FOR ALL BRANCH DUCTWORK. PROVIDE VOLUME DAMPERS FOR ALL BRANCH DUCTWORK. 6. FURNACES, ERV'S AND FANS SHALL BE LOCATED WITHIN FURNACES, ERV'S AND FANS SHALL BE LOCATED WITHIN THE ATTIC SPACE AND COORDINATED WITH EXISTING STRUCTURAL COMPONENTS. SEQUENCE OF OPERATIONS: 1. A 24/7 PROGRAMMABLE THERMOSTAT SHALL BE CAPABLE A 24/7 PROGRAMMABLE THERMOSTAT SHALL BE CAPABLE OF RUNNING THE FURNACES AT BOTH OCCUPIED AND UNOCCUPIED MODES. WHILE IN OCCUPIED MODE, THE FAN SHALL RUN CONTINUOUSLY. IN UNOCCUPIED MODE, THE FAN SHALL CYCLE AS REQUIRED TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. THE MOTORIZED OUTSIDE AIR DAMPER SHALL OPEN WHENEVER ASSOCIATED UNIT IS IN OCCUPIED MODE VIA THERMOSTAT. IN UNOCCUPIED MODE THE DAMPER SHALL REMAIN CLOSED. PROVIDE ALL WIRING, TRANSFORMERS AND RELAYS AS REQUIRED TO OPERATE AND INTERCONNECT SYSTEMS. COORDINATE WITH ELECTRICAL CONTRACTOR TO PROVIDE COMPLETE WORKING SYSTEM. 2. TOILET EXHAUST FAN ENERGIZE VIA OCCUPANCY SENSOR TOILET EXHAUST FAN ENERGIZE VIA OCCUPANCY SENSOR (BY OTHERS). COORDINATE WITH ELECTRICAL CONTRACTOR TO PROVIDE COMPLETE WORKING SYSTEM.
AutoCAD SHX Text
KEY NOTES ROUTE NEW REFRIGERANT LINES TO ASSOCIATED COOLING COIL. PROVIDE WITH PIPING COVER CHANNELS. ROUTE NEW REFRIGERANT LINES TO ASSOCIATED CONDENSING UNIT. PROVIDE INSULATION FOR ALL COOLING COILS. ROUTE CONDENSATE DISCHARGE TO CONDENSATE PUMP (LITTLE GIANT VMCA-20 OR SIMILAR) AND ROUTE 1" PUMPED CONDENSATE DISCHARGE TO CUSTODIAL CLOSET MOP SINK. ROUTE FURNACE COMBUSTION AND VENT UP THROUGH ROOF. PROVIDE INSULATION FOR ALL COMBUSTION AND VENT PIPING LOCATED WITHIN ATTIC SPACE. PROVIDE OFFSETS AS REQUIRED TO MAINTAIN 5' CLEARANCE TO MECHANICAL INTAKES. INSULATE ALL PIPING WITHIN ATTIC. ROUTE OA (SIZE AS INDICATED ON PLANS) UP TO ATTIC. PROVIDE WITH MOTORIZED DAMPER. REFER TO ATTIC PLAN FOR CONTINUATION. PROVIDE SECONDARY DRAIN PAN BENEATH UNIT WITH LEAK DETECTION SHUT OFF SWITCH. REFER TO DETAILS FOR ADDITIONAL INFORMATION. ROUTE EA TO EXTERIOR AND TERMINATE WITH HURRICANE LOUVER (20x12 RUSKIN ELF6375DXD OR SIMILAR). PROVIDE DUCT TRANSITIONS AS REQUIRED. LOUVER DEPTH TO MATCH DEPTH OF EXISTING ENVELOPE. COLOR BY ARCH. PROVIDE 4" CONCRETE HOUSEKEEPING PAD. ROUTE DUCTLESS SPLIT CONDENSATE PIPING INTO ATTIC SPACE AND TERMINATE 1" PUMPED CONDENSATE DISCHARGE AT CUSTODIAL CLOSET MOP SINK. ROUTE EA TO EXTERIOR AND TERMINATE WITH HURRICANE LOUVER (12x12 RUSKIN ELF6375DXD OR SIMILAR). PROVIDE DUCT TRANSITIONS AS REQUIRED. LOUVER DEPTH TO MATCH DEPTH OF EXISTING ENVELOPE. COLOR BY ARCH.
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
2
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
VD
AutoCAD SHX Text
CD-1 6" 70
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
CD-1 4" 15
AutoCAD SHX Text
CD-1 6" 90
AutoCAD SHX Text
EG-2 4" 15
AutoCAD SHX Text
EG-1 10" 250
AutoCAD SHX Text
6"
AutoCAD SHX Text
12x12
AutoCAD SHX Text
16x14
AutoCAD SHX Text
VD
AutoCAD SHX Text
14x12
AutoCAD SHX Text
14x12
AutoCAD SHX Text
8"
AutoCAD SHX Text
CU
AutoCAD SHX Text
1A
AutoCAD SHX Text
CU
AutoCAD SHX Text
1B
AutoCAD SHX Text
CU
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
6
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
EF
AutoCAD SHX Text
A
AutoCAD SHX Text
GF
AutoCAD SHX Text
2
AutoCAD SHX Text
GF
AutoCAD SHX Text
3
AutoCAD SHX Text
GF
AutoCAD SHX Text
4
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
4
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
16x14
AutoCAD SHX Text
3
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
2
AutoCAD SHX Text
6
AutoCAD SHX Text
3
AutoCAD SHX Text
5
AutoCAD SHX Text
12x12
AutoCAD SHX Text
VD
AutoCAD SHX Text
4"
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
6"
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
4"
AutoCAD SHX Text
6"
AutoCAD SHX Text
6"
AutoCAD SHX Text
6"
AutoCAD SHX Text
6"
AutoCAD SHX Text
6"
AutoCAD SHX Text
RG-1 12x12 460
AutoCAD SHX Text
RG-1 18x18 1185
AutoCAD SHX Text
4"
AutoCAD SHX Text
6"
AutoCAD SHX Text
(E)ATTIC ATTIC ACCESS DOOR
AutoCAD SHX Text
8"
AutoCAD SHX Text
8
AutoCAD SHX Text
T
AutoCAD SHX Text
GF-4
AutoCAD SHX Text
T
AutoCAD SHX Text
GF-2
AutoCAD SHX Text
T
AutoCAD SHX Text
GF-3
AutoCAD SHX Text
CUH
AutoCAD SHX Text
A
AutoCAD SHX Text
CUH
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
DSI-A
AutoCAD SHX Text
DSI
AutoCAD SHX Text
A
AutoCAD SHX Text
2
AutoCAD SHX Text
DSI
AutoCAD SHX Text
A
AutoCAD SHX Text
2
AutoCAD SHX Text
8
AutoCAD SHX Text
4
AutoCAD SHX Text
2
AutoCAD SHX Text
6
AutoCAD SHX Text
3
AutoCAD SHX Text
CU
AutoCAD SHX Text
4
AutoCAD SHX Text
1
AutoCAD SHX Text
8
AutoCAD SHX Text
DSO
AutoCAD SHX Text
A
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
8
AutoCAD SHX Text
CU
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
2
AutoCAD SHX Text
6
AutoCAD SHX Text
3
AutoCAD SHX Text
18x18
AutoCAD SHX Text
CD-1 10" 250 (TYP. 8)
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
RG-1 18x18 1000 (TYP. 2)
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
CD-1 10" 250 (TYP. 8)
AutoCAD SHX Text
18x18
AutoCAD SHX Text
18x18"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
18x18
AutoCAD SHX Text
CD-1 4" 40
AutoCAD SHX Text
CD-1 6" 60
AutoCAD SHX Text
EG-1 10" 250
AutoCAD SHX Text
CD-1 6" 90
AutoCAD SHX Text
RG-1 16x16 810
AutoCAD SHX Text
CD-1 6" 70
AutoCAD SHX Text
CD-1 6" 70
AutoCAD SHX Text
CD-1 6" 50
AutoCAD SHX Text
CD-1 8" 135 (TYP. 6)
AutoCAD SHX Text
CD-1 4" 35
AutoCAD SHX Text
CD-1 6" 70
AutoCAD SHX Text
CD-1 8" 140 (TYP. 8)
AutoCAD SHX Text
DSO
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
DSI-A
AutoCAD SHX Text
8
AutoCAD SHX Text
8
AutoCAD SHX Text
8
AutoCAD SHX Text
GF
AutoCAD SHX Text
1A
AutoCAD SHX Text
GF
AutoCAD SHX Text
1B
AutoCAD SHX Text
ERV
AutoCAD SHX Text
A
AutoCAD SHX Text
12" EA HIGH12" FA LOW
AutoCAD SHX Text
12" OA HIGH12" RA LOW
AutoCAD SHX Text
UH
AutoCAD SHX Text
A
AutoCAD SHX Text
10"
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
UH
AutoCAD SHX Text
A
AutoCAD SHX Text
UH
AutoCAD SHX Text
A
AutoCAD SHX Text
RG-1 18x18 1000 (TYP. 2)
AutoCAD SHX Text
RG-1 8x8 180
AutoCAD SHX Text
12x12
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
CD-1 6" 65
AutoCAD SHX Text
6"
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
9
AutoCAD SHX Text
9
AutoCAD SHX Text
T
AutoCAD SHX Text
GF-1B
AutoCAD SHX Text
T
AutoCAD SHX Text
GF-1B
AutoCAD SHX Text
12x10
AutoCAD SHX Text
12x10
AutoCAD SHX Text
EF
AutoCAD SHX Text
B
AutoCAD SHX Text
10
AutoCAD SHX Text
H
AutoCAD SHX Text
H
AutoCAD SHX Text
H
AutoCAD SHX Text
H
AutoCAD SHX Text
VD
AutoCAD SHX Text
EG-1 6" 65
AutoCAD SHX Text
VD
AutoCAD SHX Text
ER-1 8x4 65
AutoCAD SHX Text
T
AutoCAD SHX Text
EF-B
AutoCAD SHX Text
12" OA UP
AutoCAD SHX Text
12" EA UP
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
CONTRACTOR SHALL CHECK & VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO STARTING CONSTRUCTION.
AutoCAD SHX Text
21093
AutoCAD SHX Text
10/8/2021
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
10/8/21
AutoCAD SHX Text
PERMIT
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
01
AutoCAD SHX Text
MECHANICAL FLOOR PLAN
AutoCAD SHX Text
3/16" = 1'- 0"
AutoCAD SHX Text
ZCR/GJF
AutoCAD SHX Text
SLC
Page 4: P400 (24X36)

JOB NO.

DRAWN BY:

CHECKED BY:

DATE:

SCALE:

REV: DESC: DATE:

PR

OJE

CT

TIT

LE

FY

20

19

N

JD

CA

- S

MA

LL

C

IT

IE

S P

RO

GR

AM

RE

NO

VA

TIO

NS

T

O T

HE

O

LD

L

IB

RA

RY

63

01

O

CE

AN

A

VE

NU

E

WIL

DW

OO

D C

RE

ST

, N

J

NJ A

UT

H. N

O. 2

4G

A2

81

20

10

0

CO

NS

UL

TIN

G E

NG

IN

EE

RS

, L

LC

NJ L

IC

. N

O. 2

4G

E0

40

51

00

0

PR

OF

ES

SIO

NA

L E

NG

IN

EE

R

JE

FF

RE

Y A

. M

OO

RE

Te

l: (6

09

) 2

68

-0

50

0 F

ax: (6

09

) 2

68

-5

05

0

45

7 O

aksh

ad

e R

oa

d, S

ha

mo

ng

, N

J 0

80

88

MOORE

10/08/2021

ME

CH

AN

IC

AL A

TT

IC

/R

OO

F P

LA

N

M101

AutoCAD SHX Text
ERV EXHAUST TERMINATION
AutoCAD SHX Text
ERV OUTSIDE AIR INTAKE
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
DRAWING NOTES: 1. DRAWINGS ARE DIAGRAMMATIC. PROVIDE ADDITIONAL DRAWINGS ARE DIAGRAMMATIC. PROVIDE ADDITIONAL OFFSETS, TRANSITIONS, ETC. AS REQUIRED TO AVOID INTERFERENCES ENCOUNTERED. 2. CONTRACTOR SHALL PROVIDE MANUFACTURER'S CONTRACTOR SHALL PROVIDE MANUFACTURER'S RECOMMENDED CLEARANCES AND ACCESS TO ALL EQUIPMENT. COORDINATE LOCATIONS WITH OTHER TRADES TO AVOID CONFLICTS. 3. ALL EXHAUST SHALL TERMINATE ON EXTERIOR A MINIMUM ALL EXHAUST SHALL TERMINATE ON EXTERIOR A MINIMUM OF 10-FEET FROM ALL FRESH AIR INTAKES TO BUILDING. 4. EQUIPMENT LOCATIONS ARE NOT FIXED BY DIMENSIONS. EQUIPMENT LOCATIONS ARE NOT FIXED BY DIMENSIONS. COORDINATE ALL EQUIPMENT LOCATIONS WITH STRUCTURAL ENGINEER AND ARCHITECT. 5. MECHANICAL EQUIPMENT IS SHOWN ON THIS PLAN FOR MECHANICAL EQUIPMENT IS SHOWN ON THIS PLAN FOR REFERENCE. FURNACES, ERV'S, FANS SHALL BE LOCATED WITHIN THE ATTIC SPACE AND COORDINATED WITH EXISTING STRUCTURAL COMPONENTS. 6. CONTRACTOR SHALL COORDINATE THE LOCATIONS OF CONTRACTOR SHALL COORDINATE THE LOCATIONS OF PLUMBING VENTS WITH THE OUTDOOR AIR INTAKES OF THE ROOFTOP UNITS. WHERE INTAKES ARE LESS THAN 10-FEET AWAY, EXTEND THE VENT PIPING 2-FEET ABOVE THE INTAKE. FIELD VERIFY THE SIZE AND LOCATION OF ALL VENTS PRIOR TO CONSTRUCTION. (TYP.) 7. EXISTING ROOFING SYSTEM NOTE: ALL WORK PERFORMED AS EXISTING ROOFING SYSTEM NOTE: ALL WORK PERFORMED AS PART OF THIS PROJECT THAT IMPACTS OR MODIFIES THE EXISTING ROOFING SYSTEM IN ANY FORM SHALL BE PERFORMED IN A MANNER APPROVED BY THE ROOFING MANUFACTURER SUCH THAT THE EXISTING ROOF WARRANTY IN PLACE AT THE TIME OF THE WORK SHALL NOT BE VOIDED. CONTRACTOR SHALL COORDINATE ALL ROOFING WORK WITH THE ROOFING CONTRACTOR TO MAINTAIN THE ROOF'S INTEGRITY AND ALL WARRANTIES, SO AS TO MAINTAIN ORIGINAL WARRANTY AND A WATERTIGHT CONDITION ON EXISTING ROOF.
AutoCAD SHX Text
KEY NOTES: ROUTE CONCENTRIC VENT TERMINATIONS THROUGH ROOF. GROUP TERMINATIONS ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS AND CLEARANCE REQUIREMENTS. REFER TO DETAILS. ROUTE OA DUCT THROUGH ROOF FROM ATTIC BELOW AND TERMINATE WITH ROOF VENTILATOR (GREENHECK GRSI OR SIMILAR) WITH INSULATED ROOF CURB AND BIRD SCREEN. ROUTE EA DUCT THROUGH ROOF FROM ATTIC BELOW AND TERMINATE WITH ROOF VENTILATOR (GREENHECK GRSR OR SIMILAR) WITH INSULATED ROOF CURB AND BIRD SCREEN.
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
CONTRACTOR SHALL CHECK & VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO STARTING CONSTRUCTION.
AutoCAD SHX Text
21093
AutoCAD SHX Text
10/8/2021
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
10/8/21
AutoCAD SHX Text
PERMIT
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
01
AutoCAD SHX Text
MECHANICAL ATTIC/ROOF PLAN
AutoCAD SHX Text
3/16" = 1'- 0"
AutoCAD SHX Text
ZCR/GJF
AutoCAD SHX Text
SLC
Page 5: P400 (24X36)

JOB NO.

DRAWN BY:

CHECKED BY:

DATE:

SCALE:

REV: DESC: DATE:

PR

OJE

CT

TIT

LE

FY

20

19

N

JD

CA

- S

MA

LL

C

IT

IE

S P

RO

GR

AM

RE

NO

VA

TIO

NS

T

O T

HE

O

LD

L

IB

RA

RY

63

01

O

CE

AN

A

VE

NU

E

WIL

DW

OO

D C

RE

ST

, N

J

NJ A

UT

H. N

O. 24G

A28120100

CO

NS

UL

TIN

G E

NG

IN

EE

RS

, L

LC

NJ LIC

. N

O. 24G

E04051000

PR

OF

ES

SIO

NA

L E

NG

IN

EE

R

JE

FF

RE

Y A

. M

OO

RE

Tel: (609) 268-0500 F

ax: (609) 268-5050

457 O

akshade R

oad, S

ham

ong, N

J 08088

MOORE

10/08/2021

ME

CH

AN

IC

AL S

CH

ED

ULE

S

M200

AutoCAD SHX Text
CONTRACTOR SHALL CHECK & VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO STARTING CONSTRUCTION.
AutoCAD SHX Text
21093
AutoCAD SHX Text
10/8/2021
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
10/8/21
AutoCAD SHX Text
PERMIT
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
TAG
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
MODEL No.
AutoCAD SHX Text
NOMINAL CAPACITY (TONS)
AutoCAD SHX Text
OA CFM
AutoCAD SHX Text
E.S.P. IN W.G.
AutoCAD SHX Text
HP
AutoCAD SHX Text
DRIVE SPEED
AutoCAD SHX Text
TOTAL (MBH)
AutoCAD SHX Text
SENSIBLE (MBH)
AutoCAD SHX Text
INPUT (MBH)
AutoCAD SHX Text
VOLTAGE
AutoCAD SHX Text
AMP
AutoCAD SHX Text
MOCP
AutoCAD SHX Text
WEIGHT (LBS.)
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
NOTES/ACCESSORIES: 1. PROVIDE PROGRAMMABLE THERMOSTAT (LENNOX M30) WITH MODULATING FURNACE, 2-STAGE COOLING AND DEHUMIDIFICATION CONTROL AND CONTROL OF MOTORIZED OA DAMPER FOR EACH PROVIDE PROGRAMMABLE THERMOSTAT (LENNOX M30) WITH MODULATING FURNACE, 2-STAGE COOLING AND DEHUMIDIFICATION CONTROL AND CONTROL OF MOTORIZED OA DAMPER FOR EACH FURNACE. FINAL LOCATION OF THERMOSTATS SHALL BE COORDINATED WITH OWNER. 2. MATCH COIL TO UNIT AND CONDENSER. PROVIDE PLENUM AND ADAPTER WHERE REQUIRED FOR COOLING COIL INSTALLATION. MATCH COIL TO UNIT AND CONDENSER. PROVIDE PLENUM AND ADAPTER WHERE REQUIRED FOR COOLING COIL INSTALLATION. 3. PROVIDE SIDE OR BOTTOM FILTER RACK, AS REQUIRED FOR CONFIGURATION, AND MERV 8 FILTER (CAMFIL FARR 30/30 OR EQUAL). PROVIDE A MIN. OF 1 EXTRA FILTER FOR EACH UNIT. PROVIDE SIDE OR BOTTOM FILTER RACK, AS REQUIRED FOR CONFIGURATION, AND MERV 8 FILTER (CAMFIL FARR 30/30 OR EQUAL). PROVIDE A MIN. OF 1 EXTRA FILTER FOR EACH UNIT. 4. REFER TO CORRESPONDING CU SCHEDULE. REFER TO CORRESPONDING CU SCHEDULE. 5. DISCONNECT SWITCH PROVIDED BY ELECTRICAL CONTRACTOR.DISCONNECT SWITCH PROVIDED BY ELECTRICAL CONTRACTOR.
AutoCAD SHX Text
ELECTRICAL DATA
AutoCAD SHX Text
HEATING CAPACITY
AutoCAD SHX Text
DX COIL DATA
AutoCAD SHX Text
SUPPLY FAN DATA
AutoCAD SHX Text
BASIS OF DESIGN MANUF. (OR EQUAL)
AutoCAD SHX Text
GF-1A
AutoCAD SHX Text
ALL
AutoCAD SHX Text
COMMON AREA
AutoCAD SHX Text
LENNOX
AutoCAD SHX Text
GF-2
AutoCAD SHX Text
2000
AutoCAD SHX Text
5.0
AutoCAD SHX Text
0.5
AutoCAD SHX Text
445
AutoCAD SHX Text
12
AutoCAD SHX Text
120/1ɸ/60/1ɸ/60
AutoCAD SHX Text
20
AutoCAD SHX Text
235
AutoCAD SHX Text
VAR
AutoCAD SHX Text
40.3
AutoCAD SHX Text
55.8
AutoCAD SHX Text
88
AutoCAD SHX Text
GAS FURNACE WITH DX COOLING
AutoCAD SHX Text
-
AutoCAD SHX Text
GF
AutoCAD SHX Text
OUTPUT (MBH)
AutoCAD SHX Text
85
AutoCAD SHX Text
NAT GAS PRESS. (IN. W.C.)
AutoCAD SHX Text
-
AutoCAD SHX Text
STAGES
AutoCAD SHX Text
2
AutoCAD SHX Text
AFUE %
AutoCAD SHX Text
NOMINAL CFM
AutoCAD SHX Text
GF-3
AutoCAD SHX Text
GF-4
AutoCAD SHX Text
AIR DEVICE SCHEDULE
AutoCAD SHX Text
%%USUPPLY
AutoCAD SHX Text
%%UFLOW PATTERN
AutoCAD SHX Text
%%UTAG
AutoCAD SHX Text
24x24 FACE CEILING DIFFUSER EQUAL TO TITUS MODEL TDC, STEEL CONSTRUCTION, FIXED DISCHARGE, PATTERN OPTION A4, 4-WAY (UNLESS NOTED ON PLANS), BORDER TYPE 1 (SURFACE MOUNT) OR BORDER TYPE 3 (LAY-IN) AS REQUIRED, OPPOSED BLADE DAMPER, NECK SIZE AS INDICATED ON DRAWINGS. COLOR BY ARCHITECT.
AutoCAD SHX Text
NOTES/ACCESSORIES: 1. FINISH/COLOR OF ALL DIFFUSERS SHALL BE DETERMINED BY OWNER/ARCHITECT. FINISH/COLOR OF ALL DIFFUSERS SHALL BE DETERMINED BY OWNER/ARCHITECT. 2. PROVIDE 4-WAY THROW UNLESS NOTED (ARROWS) ON PLANS. PROVIDE 4-WAY THROW UNLESS NOTED (ARROWS) ON PLANS. 3. MAXIMUM PRESSURE DROP FOR SUPPLY AIR DIFFUSERS SHALL BE 0.10" W.G. MAXIMUM PRESSURE DROP FOR SUPPLY AIR DIFFUSERS SHALL BE 0.10" W.G. 4. MECHANICAL CONTRACTOR SHALL COORDINATE BORDER TYPES WITH CEILING AND WALL CONSTRUCTION. REFER TO ARCH. REFLECTED MECHANICAL CONTRACTOR SHALL COORDINATE BORDER TYPES WITH CEILING AND WALL CONSTRUCTION. REFER TO ARCH. REFLECTED CEILING PLAN. COORDINATE WITH GENERAL CONTRACTOR. 5. OPPOSED BLADE DAMPERS MAY BE OMITTED WHERE VOLUME DAMPERS ARE PROVIDED AT BRANCH RUNOUTS. OPPOSED BLADE DAMPERS MAY BE OMITTED WHERE VOLUME DAMPERS ARE PROVIDED AT BRANCH RUNOUTS. 6. DRAWING SYMBOL INFORMATION:DRAWING SYMBOL INFORMATION:
AutoCAD SHX Text
NOTE: NOT ALL DEVICES MAY BE USED ON PROJECT. NOT ALL DEVICES MAY BE USED ON PROJECT.
AutoCAD SHX Text
CD-1
AutoCAD SHX Text
12x12 FACE CEILING DIFFUSER EQUAL TO TITUS MODEL TDC, STEEL CONSTRUCTION, FIXED DISCHARGE, PATTERN OPTION A4, 4-WAY (UNLESS NOTED ON PLANS), BORDER TYPE 1 (SURFACE MOUNT) OR BORDER TYPE 3 (LAY-IN) AS REQUIRED, OPPOSED BLADE DAMPER, NECK SIZE AS INDICATED ON DRAWINGS. COLOR BY ARCHITECT.
AutoCAD SHX Text
%%URETURN
AutoCAD SHX Text
SEE PLANS
AutoCAD SHX Text
SEE PLANS
AutoCAD SHX Text
%%UEXHAUST
AutoCAD SHX Text
SEE PLANS
AutoCAD SHX Text
SEE PLANS
AutoCAD SHX Text
%%UTRANSFER GRILLE
AutoCAD SHX Text
N/A
AutoCAD SHX Text
TRANSFER GRILLE EQUAL TO HART & COOLEY MODEL 672, STEEL CONSTRUCTION, ROLL-FRAMED STEEL BORDER AND BLADES, OPPOSED BLADE DAMPER. COLOR BY ARCHITECT.
AutoCAD SHX Text
CD-2
AutoCAD SHX Text
4-WAY (UNLESS NOTED OTHERWISE)
AutoCAD SHX Text
4-WAY (UNLESS NOTED OTHERWISE)
AutoCAD SHX Text
TAG NECK SIZE CFM
AutoCAD SHX Text
RG-1
AutoCAD SHX Text
RG-2
AutoCAD SHX Text
ER-1
AutoCAD SHX Text
EG-1
AutoCAD SHX Text
TG-1
AutoCAD SHX Text
OR
AutoCAD SHX Text
24x24 RETURN GRILLE EQUAL TO TITUS MODEL PAR, STEEL CONSTRUCTION, PERFORATED FACE WITH 3/16" DIAMETER HOLES ON 1/4" STAGGERED CENTERS, HEAVY GAUGE STEEL BACKPAN, NECK SIZE AS INDICATED ON DRAWINGS. COLOR BY ARCHITECT.
AutoCAD SHX Text
RETURN GRILLE EQUAL TO TITUS MODEL 350RS, STEEL CONSTRUCTION, 3/4" BLADE SPACING, 35 DEG. DEFLECTION, ROLL-FRAMED STEEL BORDER AND BLADES, NECK SIZE AS INDICATED ON DRAWINGS. COLOR BY ARCHITECT.
AutoCAD SHX Text
TAG
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MODEL No.
AutoCAD SHX Text
HEATING CAPACITY
AutoCAD SHX Text
ELECTRICAL DATA
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
BTUH
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
VOLTAGE
AutoCAD SHX Text
AMP
AutoCAD SHX Text
MANUF.
AutoCAD SHX Text
ELECTRIC HEATER SCHEDULE
AutoCAD SHX Text
NOTES/ACCESSORIES: 1. PROVIDE MOUNTING ACCESSORIES AS REQUIRED FOR MOUNTING TYPE. PROVIDE MOUNTING ACCESSORIES AS REQUIRED FOR MOUNTING TYPE. 2. PROVIDE WITH TAMPERPROOF THERMOSTAT AND BUILT-IN DISCONNECT SWITCH. PROVIDE WITH TAMPERPROOF THERMOSTAT AND BUILT-IN DISCONNECT SWITCH. 3. FINAL COLOR SELECTION BY OWNER/ARCHITECTFINAL COLOR SELECTION BY OWNER/ARCHITECT
AutoCAD SHX Text
-
AutoCAD SHX Text
CUH
AutoCAD SHX Text
AIR COOLED CONDENSING UNIT SCHEDULE
AutoCAD SHX Text
TAG
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
BASIS OF DESIGN MANUF. (OR EQUAL)
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text
NOMINAL CAPACITY (TONS)
AutoCAD SHX Text
NOTES/ACCESSORIES: 1. PROVIDE WITH CRANKCASE HEATER, TIME OFF CONTROL. PROVIDE WITH CRANKCASE HEATER, TIME OFF CONTROL. 2. REFRIGERANT PIPE SIZES ARE O.D. AC&R COPPER TUBING. LENGTH AND SIZES SHALL BE VERIFIED WITH MANUFACTURER. REFRIGERANT PIPE SIZES ARE O.D. AC&R COPPER TUBING. LENGTH AND SIZES SHALL BE VERIFIED WITH MANUFACTURER. LENGTH AND SIZES SHALL BE VERIFIED WITH MANUFACTURER. 3. DISCONNECT SWITCH PROVIDED BY ELECTRICAL CONTRACTOR. DISCONNECT SWITCH PROVIDED BY ELECTRICAL CONTRACTOR. 4. PROVIDE REFRIGERANT LOCKING CAPS AND TWO WRENCH TOOL KITS WITH ONE EXTRA SET OF CAPS FOR THE OWNER. PROVIDE REFRIGERANT LOCKING CAPS AND TWO WRENCH TOOL KITS WITH ONE EXTRA SET OF CAPS FOR THE OWNER. 5. PROVIDE FACTORY SEACOAST PROTECTIVE ANTI-CORROSION COATING ON CONDENSER COILS. PROVIDE ADDITIONAL LUVATA PROTECTIVE PROVIDE FACTORY SEACOAST PROTECTIVE ANTI-CORROSION COATING ON CONDENSER COILS. PROVIDE ADDITIONAL LUVATA PROTECTIVE COATING FOR CASING AND OTHER COMPONENTS LOCATED OUTDOORS.
AutoCAD SHX Text
ELECTRICAL DATA
AutoCAD SHX Text
VOLTAGE
AutoCAD SHX Text
FLA
AutoCAD SHX Text
MCA
AutoCAD SHX Text
MOCP
AutoCAD SHX Text
WEIGHT (LBS)
AutoCAD SHX Text
SEER
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
-
AutoCAD SHX Text
CU
AutoCAD SHX Text
CU-1A
AutoCAD SHX Text
LENNOX
AutoCAD SHX Text
ALL
AutoCAD SHX Text
GF-1A
AutoCAD SHX Text
208/1ɸ/60
AutoCAD SHX Text
332
AutoCAD SHX Text
15.5
AutoCAD SHX Text
1.8
AutoCAD SHX Text
22
AutoCAD SHX Text
35
AutoCAD SHX Text
CU-2
AutoCAD SHX Text
FAN SCHEDULE
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
CONTROL
AutoCAD SHX Text
NOISE LEVEL (SONES)
AutoCAD SHX Text
VOLTAGE
AutoCAD SHX Text
HP/(WATTS)
AutoCAD SHX Text
FRPM
AutoCAD SHX Text
SP. IN. W.G.
AutoCAD SHX Text
CFM
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text
BASIS OF DESIGN MANUF.
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
TAG
AutoCAD SHX Text
EF-A
AutoCAD SHX Text
RESTROOMS & JANITORS CLOSET
AutoCAD SHX Text
GREENHECK
AutoCAD SHX Text
CSP-A780
AutoCAD SHX Text
515
AutoCAD SHX Text
0.5
AutoCAD SHX Text
1342
AutoCAD SHX Text
(252)
AutoCAD SHX Text
120/1ɸ/60
AutoCAD SHX Text
1.5
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
CEILING INLINE
AutoCAD SHX Text
NOTES/ACCESSORIES: 1. PROVIDE WITH INTEGRAL BACKDRAFT DAMPER AND HANGER KIT. PROVIDE WITH INTEGRAL BACKDRAFT DAMPER AND HANGER KIT. 2. DISCONNECT SWITCH PROVIDED BY ELECTRICAL CONTRACTOR. DISCONNECT SWITCH PROVIDED BY ELECTRICAL CONTRACTOR. 3. PROVIDE WITH SPEED CONTROLLER. PROVIDE WITH SPEED CONTROLLER. 4. PROVIDE WIRING, RELAYS AND THERMOSTATS FOR A COMPLETE WORKING SYSTEM.PROVIDE WIRING, RELAYS AND THERMOSTATS FOR A COMPLETE WORKING SYSTEM.
AutoCAD SHX Text
-
AutoCAD SHX Text
EF
AutoCAD SHX Text
ALL
AutoCAD SHX Text
GF-2
AutoCAD SHX Text
GF-3
AutoCAD SHX Text
GF-4
AutoCAD SHX Text
CU-3
AutoCAD SHX Text
CU-4
AutoCAD SHX Text
DUCTLESS SPLIT HEAT PUMP SYSTEM SCHEDULE
AutoCAD SHX Text
TAG
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
FAN DATA
AutoCAD SHX Text
ELECTRICAL DATA
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
SOUND LEVEL (INDOOR/OUTDOOR)
AutoCAD SHX Text
VOLTAGE
AutoCAD SHX Text
TOTAL COOLING (BTUH)
AutoCAD SHX Text
TOTAL HEATING (BTUH)
AutoCAD SHX Text
OUTDOOR CAPACITIES
AutoCAD SHX Text
DSI-A/DSO-A
AutoCAD SHX Text
AMPS
AutoCAD SHX Text
MODEL No. INDOOR/OUTDOOR
AutoCAD SHX Text
BASIS OF DESIGN MANUF.
AutoCAD SHX Text
MITSUBISHI
AutoCAD SHX Text
NOM. TONS
AutoCAD SHX Text
OA CFM
AutoCAD SHX Text
-
AutoCAD SHX Text
DSI
AutoCAD SHX Text
TOTAL COOLING (BTUH)
AutoCAD SHX Text
TOTAL HEATING (BTUH)
AutoCAD SHX Text
INDOOR CAPACITIES
AutoCAD SHX Text
CFM (LO/MED/HI)
AutoCAD SHX Text
GREENHOUSE
AutoCAD SHX Text
49/53
AutoCAD SHX Text
25
AutoCAD SHX Text
PKA-A36KA7 (QTY 2)/PUZ-A36NKA7-BS (QTY 2)
AutoCAD SHX Text
3.0 EA.
AutoCAD SHX Text
-
AutoCAD SHX Text
36,000
AutoCAD SHX Text
25,900
AutoCAD SHX Text
705/810/920
AutoCAD SHX Text
ALL
AutoCAD SHX Text
208/1ɸ/60
AutoCAD SHX Text
E.S.P. IN W.G.
AutoCAD SHX Text
-
AutoCAD SHX Text
MOCP
AutoCAD SHX Text
31
AutoCAD SHX Text
NOTE/ACCESSORIES: 1. PROVIDE WITH WIRED REMOTE CONTROLLER/THERMOSTATS CAPABLE OF AUTO SWITCH-OVER. PROVIDE WITH WIRED REMOTE CONTROLLER/THERMOSTATS CAPABLE OF AUTO SWITCH-OVER. 2. DISCONNECT SWITCH SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR FOR EACH ITEM. COORDINATE POWER & WIRING REQUIREMENTS WITH ELECTRICAL CONTRACTOR. DISCONNECT SWITCH SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR FOR EACH ITEM. COORDINATE POWER & WIRING REQUIREMENTS WITH ELECTRICAL CONTRACTOR. 3. PROVIDE EACH INDOOR UNIT WITH CONDENSATE PUMPS AND COVER. PROVIDE EACH INDOOR UNIT WITH CONDENSATE PUMPS AND COVER. 4. UNIT SHALL BE WALL MOUNTED, PROVIDE MOUNTING ACCESSORIES AS REQUIRED FOR MOUNTING TYPE. UNIT SHALL BE WALL MOUNTED, PROVIDE MOUNTING ACCESSORIES AS REQUIRED FOR MOUNTING TYPE. 5. PROVIDE WITH PIPING COVER CHANNELS FOR REFRIGERANT AND CONDENSATE PIPING (DIVERSITECH SPEEDICHANNEL OR SIMILAR) PROVIDE WITH PIPING COVER CHANNELS FOR REFRIGERANT AND CONDENSATE PIPING (DIVERSITECH SPEEDICHANNEL OR SIMILAR) 6. PROVIDE WITH REFRIGERANT PIPE LOCKING CAPS.PROVIDE WITH REFRIGERANT PIPE LOCKING CAPS.
AutoCAD SHX Text
CUH-A
AutoCAD SHX Text
VESTIBULES
AutoCAD SHX Text
WALL HEATER
AutoCAD SHX Text
-
AutoCAD SHX Text
1500
AutoCAD SHX Text
120/1 /60
AutoCAD SHX Text
12.9
AutoCAD SHX Text
INDEECO
AutoCAD SHX Text
ALL
AutoCAD SHX Text
933U01500B
AutoCAD SHX Text
SSB060
AutoCAD SHX Text
MANUF.
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text
S/A
AutoCAD SHX Text
CFM
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
ENERGY RECOVERY UNIT SCHEDULE
AutoCAD SHX Text
TAG
AutoCAD SHX Text
O/A
AutoCAD SHX Text
R/A
AutoCAD SHX Text
E/A
AutoCAD SHX Text
POWER
AutoCAD SHX Text
FLA
AutoCAD SHX Text
NOTES/ACCESSORIES: 1. PROVIDE WITH MERV 8 FILTERS. PROVIDE WITH MERV 8 FILTERS. 2. PROVIDE WITH ECM MOTOR. PROVIDE WITH ECM MOTOR. 3. PROVIDE WITH BACKDRAFT DAMPERS PROVIDE WITH BACKDRAFT DAMPERS 4. PROVIDE WITH SPEED CONTROLLER, WALL MOUNTED DIGITAL TIME CLOCK, AND DUCT MOUNTED CARBON DIOXIDE SENSOR. PROVIDE ALL WIRING, TRANSFORMERS, AND RELAYS AS PROVIDE WITH SPEED CONTROLLER, WALL MOUNTED DIGITAL TIME CLOCK, AND DUCT MOUNTED CARBON DIOXIDE SENSOR. PROVIDE ALL WIRING, TRANSFORMERS, AND RELAYS AS REQUIRED. COORDINATE INTERCONNECTION WITH ELECTRICAL CONTRACTOR. COORDINATE FINAL LOCATION OF TIME CLOCK WITH OWNER/ARCHITECT. 5. PROVIDE WITH STANDARD DISCONNECT SWITCH. COORDINATE WITH ELECTRICAL CONTRACTOR. PROVIDE WITH STANDARD DISCONNECT SWITCH. COORDINATE WITH ELECTRICAL CONTRACTOR. 6. PROVIDE WITH MOTORIZED ISOLATION DAMPERS IN OA AND EA AIR STREAMS.PROVIDE WITH MOTORIZED ISOLATION DAMPERS IN OA AND EA AIR STREAMS.
AutoCAD SHX Text
ELECTRIC
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
RENEWAIRE
AutoCAD SHX Text
ERV-1
AutoCAD SHX Text
HE1XINH
AutoCAD SHX Text
(2) @ 4.5
AutoCAD SHX Text
GF-1A & GF-1B
AutoCAD SHX Text
ALL
AutoCAD SHX Text
120/1ɸ/60
AutoCAD SHX Text
-
AutoCAD SHX Text
ERV
AutoCAD SHX Text
WEIGHT (LBS)
AutoCAD SHX Text
275
AutoCAD SHX Text
MCA
AutoCAD SHX Text
(2) @ 10.1
AutoCAD SHX Text
MOCP
AutoCAD SHX Text
(2) @ 15
AutoCAD SHX Text
890
AutoCAD SHX Text
890
AutoCAD SHX Text
890
AutoCAD SHX Text
890
AutoCAD SHX Text
ZCR/GJF
AutoCAD SHX Text
SLC
AutoCAD SHX Text
BACK OF HOUSE
AutoCAD SHX Text
HISTORICAL
AutoCAD SHX Text
SENIOR CENTER
AutoCAD SHX Text
GF-1B
AutoCAD SHX Text
COMMON AREA
AutoCAD SHX Text
CU-1B
AutoCAD SHX Text
GF-1B
AutoCAD SHX Text
2.0
AutoCAD SHX Text
3.0
AutoCAD SHX Text
4.0
AutoCAD SHX Text
85
AutoCAD SHX Text
170
AutoCAD SHX Text
340
AutoCAD SHX Text
5.0
AutoCAD SHX Text
5.0
AutoCAD SHX Text
2.0
AutoCAD SHX Text
3.0
AutoCAD SHX Text
4.0
AutoCAD SHX Text
LENNOX
AutoCAD SHX Text
208/1ɸ/60
AutoCAD SHX Text
SSB060
AutoCAD SHX Text
LENNOX
AutoCAD SHX Text
208/1ɸ/60
AutoCAD SHX Text
16ACX-024
AutoCAD SHX Text
LENNOX
AutoCAD SHX Text
208/1ɸ/60
AutoCAD SHX Text
LENNOX
AutoCAD SHX Text
208/1ɸ/60
AutoCAD SHX Text
SSB048
AutoCAD SHX Text
16ACX-036
AutoCAD SHX Text
ALL
AutoCAD SHX Text
190
AutoCAD SHX Text
16.0
AutoCAD SHX Text
-
AutoCAD SHX Text
16
AutoCAD SHX Text
20
AutoCAD SHX Text
ALL
AutoCAD SHX Text
-
AutoCAD SHX Text
16
AutoCAD SHX Text
25
AutoCAD SHX Text
ALL
AutoCAD SHX Text
260
AutoCAD SHX Text
16.0
AutoCAD SHX Text
1.7
AutoCAD SHX Text
20
AutoCAD SHX Text
30
AutoCAD SHX Text
ML296UH045
AutoCAD SHX Text
ML296UH090
AutoCAD SHX Text
ML296UH070
AutoCAD SHX Text
LENNOX
AutoCAD SHX Text
LENNOX
AutoCAD SHX Text
LENNOX
AutoCAD SHX Text
LENNOX
AutoCAD SHX Text
EL296UH090
AutoCAD SHX Text
EL296UH090
AutoCAD SHX Text
120/1ɸ/60/1ɸ/60
AutoCAD SHX Text
800
AutoCAD SHX Text
12
AutoCAD SHX Text
120/1ɸ/60/1ɸ/60
AutoCAD SHX Text
15
AutoCAD SHX Text
180
AutoCAD SHX Text
VAR
AutoCAD SHX Text
16.6
AutoCAD SHX Text
23.4
AutoCAD SHX Text
44
AutoCAD SHX Text
42
AutoCAD SHX Text
-
AutoCAD SHX Text
2
AutoCAD SHX Text
95
AutoCAD SHX Text
1200
AutoCAD SHX Text
12
AutoCAD SHX Text
120/1ɸ/60/1ɸ/60
AutoCAD SHX Text
15
AutoCAD SHX Text
190
AutoCAD SHX Text
VAR
AutoCAD SHX Text
24.5
AutoCAD SHX Text
34.7
AutoCAD SHX Text
66
AutoCAD SHX Text
62
AutoCAD SHX Text
-
AutoCAD SHX Text
2
AutoCAD SHX Text
1600
AutoCAD SHX Text
12
AutoCAD SHX Text
120/1ɸ/60/1ɸ/60
AutoCAD SHX Text
15
AutoCAD SHX Text
235
AutoCAD SHX Text
VAR
AutoCAD SHX Text
33.2
AutoCAD SHX Text
45.3
AutoCAD SHX Text
88
AutoCAD SHX Text
84
AutoCAD SHX Text
-
AutoCAD SHX Text
2
AutoCAD SHX Text
15.5
AutoCAD SHX Text
245
AutoCAD SHX Text
36,000
AutoCAD SHX Text
25,900
AutoCAD SHX Text
0.5
AutoCAD SHX Text
0.5
AutoCAD SHX Text
0.5
AutoCAD SHX Text
0.5
AutoCAD SHX Text
0.5
AutoCAD SHX Text
0.5
AutoCAD SHX Text
0.5
AutoCAD SHX Text
ALL
AutoCAD SHX Text
ALL
AutoCAD SHX Text
ALL
AutoCAD SHX Text
95
AutoCAD SHX Text
95
AutoCAD SHX Text
95
AutoCAD SHX Text
332
AutoCAD SHX Text
15.5
AutoCAD SHX Text
1.8
AutoCAD SHX Text
22
AutoCAD SHX Text
35
AutoCAD SHX Text
2000
AutoCAD SHX Text
5.0
AutoCAD SHX Text
0.5
AutoCAD SHX Text
445
AutoCAD SHX Text
VAR
AutoCAD SHX Text
40.3
AutoCAD SHX Text
55.8
AutoCAD SHX Text
88
AutoCAD SHX Text
85
AutoCAD SHX Text
-
AutoCAD SHX Text
2
AutoCAD SHX Text
0.5
AutoCAD SHX Text
95
AutoCAD SHX Text
12
AutoCAD SHX Text
20
AutoCAD SHX Text
235
AutoCAD SHX Text
ALL
AutoCAD SHX Text
ALL
AutoCAD SHX Text
UH-A
AutoCAD SHX Text
BACK OF HOUSE SPACES
AutoCAD SHX Text
CEILING MNTD HEATER
AutoCAD SHX Text
-
AutoCAD SHX Text
2000
AutoCAD SHX Text
208/3 /60
AutoCAD SHX Text
6.3
AutoCAD SHX Text
INDEECO
AutoCAD SHX Text
ALL
AutoCAD SHX Text
926U02000DA
AutoCAD SHX Text
EF-B
AutoCAD SHX Text
MECHANICAL & ELECTRICAL ROOMS
AutoCAD SHX Text
GREENHECK
AutoCAD SHX Text
CSP-A200
AutoCAD SHX Text
110
AutoCAD SHX Text
0.6
AutoCAD SHX Text
825
AutoCAD SHX Text
(119)
AutoCAD SHX Text
120/1ɸ/60
AutoCAD SHX Text
1.4
AutoCAD SHX Text
T-STAT
AutoCAD SHX Text
CEILING INLINE
AutoCAD SHX Text
ALL
AutoCAD SHX Text
EXHAUST GRILLE EQUAL TO TITUS MODEL 350FL, ALUMINUM CONSTRUCTION, 3/4" BLADE SPACING, 35 DEG. DEFLECTION, ROLL-FRAMED STEEL BORDER AND BLADES, NECK SIZE AS INDICATED ON DRAWINGS. COLOR BY ARCHITECT.
AutoCAD SHX Text
24x24 EXHAUST GRILLE EQUAL TO TITUS MODEL PAR-AA, ALUMINUM CONSTRUCTION, 3/16" DIAMETER HOLES ON 1/4" STAGGERED CENTERS, HEAVY GAUGE STEEL BACKPAN, OPPOSED BLADE DAMPER, NECK SIZE AS INDICATED ON DRAWINGS. COLOR BY ARCHITECT.
AutoCAD SHX Text
SEE PLANS
AutoCAD SHX Text
EG-2
AutoCAD SHX Text
12x12 EXHAUST GRILLE EQUAL TO TITUS MODEL PAR-AA, ALUMINUM CONSTRUCTION, 3/16" DIAMETER HOLES ON 1/4" STAGGERED CENTERS, HEAVY GAUGE STEEL BACKPAN, OPPOSED BLADE DAMPER, NECK SIZE AS INDICATED ON DRAWINGS. COLOR BY ARCHITECT.
Page 6: P400 (24X36)

JOB NO.

DRAWN BY:

CHECKED BY:

DATE:

SCALE:

REV: DESC: DATE:

PR

OJE

CT

TIT

LE

FY

20

19

N

JD

CA

- S

MA

LL

C

IT

IE

S P

RO

GR

AM

RE

NO

VA

TIO

NS

T

O T

HE

O

LD

L

IB

RA

RY

63

01

O

CE

AN

A

VE

NU

E

WIL

DW

OO

D C

RE

ST

, N

J

NJ A

UT

H. N

O. 24G

A28120100

CO

NS

UL

TIN

G E

NG

IN

EE

RS

, L

LC

NJ LIC

. N

O. 24G

E04051000

PR

OF

ES

SIO

NA

L E

NG

IN

EE

R

JE

FF

RE

Y A

. M

OO

RE

Tel: (609) 268-0500 F

ax: (609) 268-5050

457 O

akshade R

oad, S

ham

ong, N

J 08088

MOORE

10/08/2021

ME

CH

AN

IC

AL D

ET

AILS

M300

AutoCAD SHX Text
CONTRACTOR SHALL CHECK & VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO STARTING CONSTRUCTION.
AutoCAD SHX Text
21093
AutoCAD SHX Text
10/8/2021
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
10/8/21
AutoCAD SHX Text
PERMIT
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
HARD ELBOW
AutoCAD SHX Text
D MINIMUM
AutoCAD SHX Text
ROUND DUCT ADAPTOR FOR RECTANGULAR DIFFUSER
AutoCAD SHX Text
THERMAL INSULATION, SEAL AROUND ALL EDGES
AutoCAD SHX Text
2-3/4 IN. MINIMUM
AutoCAD SHX Text
R=D
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
TOP CONNECTION
AutoCAD SHX Text
MAXIMUM 6 FT. LENGTH FLEXIBLE DUCT FULLY EXTENDED
AutoCAD SHX Text
PROVIDE MULTIPLE SUPPORTS (THERMAFLEX "FLEXTIE" OR EQUAL) TO LIMIT SAG. (TYP)
AutoCAD SHX Text
D
AutoCAD SHX Text
WORM GEAR DRAW BAND SEE NOTE BELOW AND SPECIFICATIONS
AutoCAD SHX Text
DETAIL NOTES: : 1. SUPPORT FLEXIBLE DUCT TO AVOID DEFLECTION. NO ABRUPT SUPPORT FLEXIBLE DUCT TO AVOID DEFLECTION. NO ABRUPT CHANGES IN DIRECTION OF FLEXIBLE DUCTWORK SHALL BE ACCEPTABLE. MAX. CHANGES IN DIRECTION SHALL BE 15 DEGREES. 2. FOLLOW SMACNA STANDARDS FOR SUPPORTS AND HANGERS. FOLLOW SMACNA STANDARDS FOR SUPPORTS AND HANGERS.
AutoCAD SHX Text
DIFFUSER
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
01
AutoCAD SHX Text
ELBOW AT DIFFUSER CONNECTION DETAIL
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
D
AutoCAD SHX Text
FLEXIBLE DUCT TO TROFFER OR DIFFUSER
AutoCAD SHX Text
ROUND VOLUME DAMPER SEE DETAIL
AutoCAD SHX Text
SHEET METAL AS REQUIRED
AutoCAD SHX Text
MAIN DUCT
AutoCAD SHX Text
AIRFLOW
AutoCAD SHX Text
1.5D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
02
AutoCAD SHX Text
CIRCULAR BRANCH CONNECTION
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
RETURN/EXHAUST AIR
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
TAPERED CONNECTION 45° ANGLE (IF MAINDUCT IS RECTANGULAR) OR CONICAL CONNECTION (IF MAIN DUCT IS ROUND) L=1/4 W; 4"MIN
AutoCAD SHX Text
BRANCH DUCT
AutoCAD SHX Text
MAIN DUCT
AutoCAD SHX Text
W
AutoCAD SHX Text
VD
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
03
AutoCAD SHX Text
BRANCH TAKE-OFFS
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
LOCKNUT
AutoCAD SHX Text
INDICATING HANDLE
AutoCAD SHX Text
GASKET
AutoCAD SHX Text
VENTLOCK NO. 635 REGULATOR
AutoCAD SHX Text
VENTLOCK NO. 609 END BEARING
AutoCAD SHX Text
3/8" SQ. ROD
AutoCAD SHX Text
GASKET
AutoCAD SHX Text
SECTION A-A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
3/8" SQ. ROD
AutoCAD SHX Text
SPOT WELD
AutoCAD SHX Text
16 GA. GALV. BLADE
AutoCAD SHX Text
1" x 1/8" GALV. STRAPS
AutoCAD SHX Text
1/4" SET SCREW
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
04
AutoCAD SHX Text
TYPICAL ROUND VOLUME DAMPER DETAIL
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
FLEXIBLE DUCTWORK ELBOW SUPPORT. (THERMAFLEX "FLEX FLOW ELBOW" OR EQUAL)
AutoCAD SHX Text
ROUND DUCT ADAPTOR FOR RECTANGULAR DIFFUSER
AutoCAD SHX Text
THERMAL INSULATION, SEAL AROUND ALL EDGES
AutoCAD SHX Text
2-3/4 IN. MINIMUM
AutoCAD SHX Text
R=D
AutoCAD SHX Text
TOP CONNECTION
AutoCAD SHX Text
DETAIL NOTES: : 1. SUPPORT FLEXIBLE DUCT TO AVOID DEFLECTION. NO ABRUPT SUPPORT FLEXIBLE DUCT TO AVOID DEFLECTION. NO ABRUPT CHANGES IN DIRECTION OF FLEXIBLE DUCTWORK SHALL BE ACCEPTABLE. MAX. CHANGES IN DIRECTION SHALL BE 15 DEGREES. 2. FOLLOW SMACNA STANDARDS FOR SUPPORTS AND HANGERS. FOLLOW SMACNA STANDARDS FOR SUPPORTS AND HANGERS. 3. SIDE CONNECTION WITH HARD DUCT SIMILAR FOR RETURN.SIDE CONNECTION WITH HARD DUCT SIMILAR FOR RETURN.
AutoCAD SHX Text
MAXIMUM 6 FT. LENGTH FLEXIBLE DUCT FULLY EXTENDED
AutoCAD SHX Text
PROVIDE MULTIPLE SUPPORTS (THERMAFLEX "FLEXTIE" OR EQUAL) TO LIMIT SAG. (TYP)
AutoCAD SHX Text
FLEXIBLE DUCT. REFER TO TOP CONNECTION FOR REQUIREMENTS
AutoCAD SHX Text
ROUND DUCT CONNECTOR ACOUSTIC LINING
AutoCAD SHX Text
DIFFUSER NECK SIZE
AutoCAD SHX Text
6" MINIMUM
AutoCAD SHX Text
DIFFUSER
AutoCAD SHX Text
SIDE CONNECTION
AutoCAD SHX Text
THERMAL INSULATION, SEAL AROUND ALL EDGES.
AutoCAD SHX Text
EXTERNALLY INSULATED PLENUM
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
D MINIMUM
AutoCAD SHX Text
DIFFUSER
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
05
AutoCAD SHX Text
DIFFUSER CONNECTION DETAILS
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
%%UALL SIZES
AutoCAD SHX Text
SECURE SUPPORT ROD TO STRUCTURE WITH CONCRETE INSERT FISHPLATE OR BEAM CLAMP AS APPLICABLE
AutoCAD SHX Text
HANGER RODS
AutoCAD SHX Text
FORGED STEEL CLEVIS HANGER
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
12" LONG X 16 GAUGE SHIELD
AutoCAD SHX Text
12" LONG HALF SECTION OF CALCIUM SILICATE WITH VAPOR BARRIER EXTEND 2" OVER EACH END
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
DETAIL NOTES: : 1. WHERE STRUCTURAL SLAB DOES NOT PERMIT INSERTS. SUPPORT PIPING FROM STRUCTURE WITH AUXILIARY STEEL IF REQUIRED.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
06
AutoCAD SHX Text
WATER PIPING HANGER DETAIL
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
DETAIL NOTES: : 1. PROVIDE SUPPORT STEEL CHANNELS FOR UNITS SUPPORTED FROM PROVIDE SUPPORT STEEL CHANNELS FOR UNITS SUPPORTED FROM OVER-HEAD JOISTS. COORDINATE SUPPORTS WITH ARCHITECT AND ENGINEER. 2. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS AND REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS AND OPERATING WEIGHTS. 3. PROVIDE SIZE THREADED RODS, QUANTITY OF RODS, AND VIBRATION PROVIDE SIZE THREADED RODS, QUANTITY OF RODS, AND VIBRATION ISOLATORS AS RECOMMENDED BY EQUIPMENT MANUFACTURER.
AutoCAD SHX Text
LOW PRESSURE DUCTWORK
AutoCAD SHX Text
FAN
AutoCAD SHX Text
FLEXIBLE DUCT CONNECTIONS
AutoCAD SHX Text
FLEXIBLE DUCT CONNECTIONS
AutoCAD SHX Text
LOW PRESSURE DUCTWORK
AutoCAD SHX Text
THREADED RODS. QUANTITY AND SIZE PER FAN/AHU MANUFACTURERS RECOMMENDATIONS
AutoCAD SHX Text
VIBRATION ISOLATORS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
07
AutoCAD SHX Text
FAN/AC MOUNTING DETAIL
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
08
AutoCAD SHX Text
GRAVITY RELIEF INTAKE/VENT DETAIL
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
VENT HOUSING
AutoCAD SHX Text
CURB
AutoCAD SHX Text
3/4" NEOPRENE FOAM ALL AROUND FURNISHED & INSTALLED BY MECHANICAL CONTRACTOR
AutoCAD SHX Text
GRAVITY VENT
AutoCAD SHX Text
PITCHED ROOF
AutoCAD SHX Text
EXHAUST DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DETAIL NOTES: : 1. FASTEN CURB TO STRUCTURE WITH " S.S. LAG SCREWS OR BOLTS WITH FASTEN CURB TO STRUCTURE WITH " S.S. LAG SCREWS OR BOLTS WITH 12" S.S. LAG SCREWS OR BOLTS WITH WASHERS (1) PER SIDE. FASTEN CAP TO CURB WITH #10 S.S. SCREWS.
AutoCAD SHX Text
SHIELD ATTACHED TO CLEVIS HANGER
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
16 GAUGE GALV. STEEL SHIELD. TYP FOR PIPE HANGERS.
AutoCAD SHX Text
FIBERGLASS INSULATION TYPICAL FOR ALL INSULATED PIPING.
AutoCAD SHX Text
ADJUSTABLE CLEVIS HANGER
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
09
AutoCAD SHX Text
INSULATED PIPE HANGER DETAIL
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
ELBOW (FIELD SUPPLIED)
AutoCAD SHX Text
COMBUSTION AIR
AutoCAD SHX Text
MAINTAIN 12" MIN CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL MAXIMUM OF 24" ABOVE ROOF
AutoCAD SHX Text
COMBUSTION AIR
AutoCAD SHX Text
VENT
AutoCAD SHX Text
EXHAUST VENT
AutoCAD SHX Text
ROOF BOOT/FLASHING (FIELD SUPPLIED)
AutoCAD SHX Text
SUPPORT FROM STRUCTURE (FIELD SUPPLIED)
AutoCAD SHX Text
SS BANDING WITH SEALANT
AutoCAD SHX Text
INSULATE PER MANUFACTURER'S SPECIFICATIONS
AutoCAD SHX Text
DETAIL NOTES: : 1. INSTALL AND SEAL PIPE PORTAL/FLASHING PER MANUFACTURER DIRECTION. INSTALL AND SEAL PIPE PORTAL/FLASHING PER MANUFACTURER DIRECTION. 2. USE CPVC PIPE VENTING MATERIALS. USE CPVC PIPE VENTING MATERIALS. 3. PROVIDE AND INSTALL FLUE EXHAUST AND AIR INTAKE CONCENTRIC KIT FOR EACH PROVIDE AND INSTALL FLUE EXHAUST AND AIR INTAKE CONCENTRIC KIT FOR EACH APPLIANCE PER MANUFACTURER'S DIRECTION. 4. SUPPORT SHALL BE FIELD INSTALLED TO SECURE TERMINATION KIT TO STRUCTURE. SUPPORT SHALL BE FIELD INSTALLED TO SECURE TERMINATION KIT TO STRUCTURE. 5. ALL VENT/FLUE PIPING PASSING THROUGH UNHEATED PORTIONS OF THE BUILDING ALL VENT/FLUE PIPING PASSING THROUGH UNHEATED PORTIONS OF THE BUILDING SUBJECT TO FREEZING, SHALL BE INSULATED PER MANUFACTURER'S INSTRUCTION. 6. FOR FLUE VENT PIPING WITHIN AN AIR PLENUM PROVIDE FIREMASTER FOR FLUE VENT PIPING WITHIN AN AIR PLENUM PROVIDE FIREMASTER PLENUMWRAP (UL LISTED HNLJ V19) TO PROVIDE AN ENCLOSURE AND ENCAPSULATION AS REQUIRED PER CODE AND THE AHJ. 7. TWO OR MORE DIRECT VENT VERTICAL TERMINATIONS ARE VENTED NEAR EACH TWO OR MORE DIRECT VENT VERTICAL TERMINATIONS ARE VENTED NEAR EACH OTHER, THEY SHALL BE A MINIMUM 18" APART TO AVOID RECIRCULATION OF FLUE GASES OR AS DIRECTED BY MANUFACTURER'S DIRECTION.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
10
AutoCAD SHX Text
CONCENTRIC ROOF VENT DETAIL
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
HANGER RODS
AutoCAD SHX Text
1/4" NEOPRENE WASHER
AutoCAD SHX Text
SPRING ISOLATOR (TYP. OF 4)
AutoCAD SHX Text
MOUNTING BRACKET
AutoCAD SHX Text
FLEXIBLE CONN. (TYP.)
AutoCAD SHX Text
THROWAWAY FILTER WITH SIDE ACCESS
AutoCAD SHX Text
REF. PIPING
AutoCAD SHX Text
TRAPPED COND. LINE
AutoCAD SHX Text
TRAPPED SECONDARY DRAIN LINE (WHERE REQUIRED)
AutoCAD SHX Text
SUPPLY AIR DUCT REFER TO PLANS FOR SIZES LINE DUCT FOR A MIN. OF 5'-0" PAST THE 1st ELBOW OR 15'-0" WHICH EVER IS GREATER
AutoCAD SHX Text
SECONDARY DRAIN PAN
AutoCAD SHX Text
WATER SENSOR
AutoCAD SHX Text
DETAIL NOTES: : 1. SLOPE CONDENSATE LINE 1/8" PER 1'-0". SLOPE CONDENSATE LINE 1/8" PER 1'-0". 2. SECONDARY DRAIN PAN SHALL BE MIN 14 GA. GALVANIZED SHEET METAL WITH WELDED CORNERS AND MIN. SECONDARY DRAIN PAN SHALL BE MIN 14 GA. GALVANIZED SHEET METAL WITH WELDED CORNERS AND MIN. 2" HIGH EDGES. EXTEND PAN MIN. 6" ALL AROUND UNIT. 3. SIZE AND INSTALL REFRIGERANT LIQUID AND SUCTION LINES PER MANUFACTURER'S RECOMMENDATIONS AND SIZE AND INSTALL REFRIGERANT LIQUID AND SUCTION LINES PER MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS. 4. PROVIDE SIMILAR FOR VERTICAL FLOOR MOUNTED UNITS. PROVIDE INTERNAL WATER LEVEL SHUTOFF FOR PROVIDE SIMILAR FOR VERTICAL FLOOR MOUNTED UNITS. PROVIDE INTERNAL WATER LEVEL SHUTOFF FOR VERTICAL UNITS WHERE SECONDARY DRAIN PANS CANNOT BE UTILIZED. 5. REFER TO PIPING DETAIL.REFER TO PIPING DETAIL.
AutoCAD SHX Text
RETURN AIR DUCT REFER TO PLANS FOR SIZES LINE DUCT FOR A MIN. OF 5'-0" PAST THE 1st ELBOW OR 15'-0" WHICHEVER IS GREATER
AutoCAD SHX Text
WIRED TO SHUT DOWN UNIT
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
11
AutoCAD SHX Text
AC UNIT &
AutoCAD SHX Text
FURNACE MOUNTING DETAIL
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
PITCH
AutoCAD SHX Text
DRAIN PAN
AutoCAD SHX Text
DRAW THRU DETAIL NOTES: : 1. X" =MINIMUM DROP EQUAL TO NEGATIVE INTERNAL STATIC PRESSURE AT FAN INLET. X" =MINIMUM DROP EQUAL TO NEGATIVE INTERNAL STATIC PRESSURE AT FAN INLET. 2. X/2 + 1" = (MINIMUM 5 INCHES). X/2 + 1" = (MINIMUM 5 INCHES). 3. ADD STRUCTURAL STEEL TO RAISE THE BOTTOM OF THE UNIT TO ACCOMMODATE DROP AND TRAP ADD STRUCTURAL STEEL TO RAISE THE BOTTOM OF THE UNIT TO ACCOMMODATE DROP AND TRAP HEIGHT. 4. PITCH DRAIN FOR PROPER RUN-OFF AND DISCHARGE TO APPROVED RECEPTACLE. PITCH DRAIN FOR PROPER RUN-OFF AND DISCHARGE TO APPROVED RECEPTACLE. 5. SUPPORT DRAIN LINES TO PREVENT SAG AND CONDENSATE OVERFLOW. SUPPORT DRAIN LINES TO PREVENT SAG AND CONDENSATE OVERFLOW. 6. MANUALLY PRIME FILL TRAP BEFORE START-UP TO FORM INITIAL DRAIN SEAL.MANUALLY PRIME FILL TRAP BEFORE START-UP TO FORM INITIAL DRAIN SEAL.
AutoCAD SHX Text
DISCHARGE MUST BE BELOW LEVEL OF DRAIN PAN
AutoCAD SHX Text
CLEANOUT PLUG
AutoCAD SHX Text
NIPPLE
AutoCAD SHX Text
TEE
AutoCAD SHX Text
RETURN BEND
AutoCAD SHX Text
DRAW THRU DROP SEE NOTE 1
AutoCAD SHX Text
DRAW THRU LEG SEE NOTE 2
AutoCAD SHX Text
DRAIN CONNECTION (1-1/4" FPT MINIMUM)
AutoCAD SHX Text
BLOW THRU DETAIL NOTES: : A. 1" MIN. DROP REQUIRED USE OF STANDARD FITTINGS SHOWN EXCEEDS THIS MINIMUM. 1" MIN. DROP REQUIRED USE OF STANDARD FITTINGS SHOWN EXCEEDS THIS MINIMUM. B. Y + 1" =LEG FOR BLOW-THRU UNIT WHERE Y=DISCHARGE PRESSURE OF FAN. (MIN. 7"). Y + 1" =LEG FOR BLOW-THRU UNIT WHERE Y=DISCHARGE PRESSURE OF FAN. (MIN. 7"). C. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR TRAP. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR TRAP. D. PITCH DRAIN FOR PROPER RUN-OFF AND DISCHARGE TO APPROVED RECEPTACLE. PITCH DRAIN FOR PROPER RUN-OFF AND DISCHARGE TO APPROVED RECEPTACLE. E. SUPPORT DRAIN LINES TO PREVENT SAG AND CONDENSATE OVERFLOW. SUPPORT DRAIN LINES TO PREVENT SAG AND CONDENSATE OVERFLOW. F. MANUALLY PRIME FILL TRAP BEFORE START-UP TO TO FORM INITIAL DRAIN SEAL. MANUALLY PRIME FILL TRAP BEFORE START-UP TO TO FORM INITIAL DRAIN SEAL. G. PROVIDE OVERFLOW DRAIN WITH TRAP SENSOR TO DE-ENERGIZE VERTICAL MOUNTED UNITS PROVIDE OVERFLOW DRAIN WITH TRAP SENSOR TO DE-ENERGIZE VERTICAL MOUNTED UNITS ON CONDENSATE OVERFLOW.
AutoCAD SHX Text
BLOW THRU DROP SEE NOTE A
AutoCAD SHX Text
BLOW THRU LEG SEE NOTE B
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
12
AutoCAD SHX Text
DRAIN PAN WATER SEAL DETAIL
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
BUTT ENDS & SEAL
AutoCAD SHX Text
PROVIDE LOCKING QUADRANT ARM STANDOFF
AutoCAD SHX Text
DETAIL NOTES: FOR HANGING DUCT: TRAPEZE DUCT OR STRAP HANGER AROUND DUCT COMPLETELY. DO NOT USE ANY SCREWS, BECAUSE THEY INTERFERE WITH DAMPER BLADE(S).