Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
www.osram-os.com
OS-PCN-2020-013-A
Introduction of Backend production location Wuxi for
premolded detector products and other changes
Customer information package
OS QM CQM | 15.07.2020
Light is OSRAM
Customer information package | OS QM CQM
OS-PCN-2020-013-A Introduction of Backend production location | 15.07.2020
2
OS-PCN-2020-013-A
Introduction of Backend production location Wuxi for
premolded detector products and other changes
Page
1. Reason for change 3
2. Description of change 4
3. List of affected products 7
4. PCN samples 8
5. Time schedule 9
Customer information package | OS QM CQM
OS-PCN-2020-013-A Introduction of Backend production location | 15.07.2020
3
Reason for change
OS-PCN-2020-013-A
Introduction of Backend production location Wuxi for
premolded detector products and other changes
Item Description
1 Introduction of backend production location Wuxi for premolded detector
products to secure continuous supply and to increase production capacity.
For better traceability, laser marking on device will be rotated by 180° for
devices assembled at location Wuxi.
2 Only applicable for SFH 320G:
produced at backend location Wuxi:
Harmonization of plating composition from NiAu with NiSn plating finish to
NiPdAu without NiSn plating finish.
Harmonization of casting resin with higher glass transition temperature
(Tg).
Customer information package | OS QM CQM
OS-PCN-2020-013-A Introduction of Backend production location | 15.07.2020
4
OS-PCN-2020-013-A
Introduction of Backend production location Wuxi for
premolded detector products and other changes
Current status New status
Production location Penang/Malaysia:
-> No laser marking rotation.
Production location Penang/Malaysia:-> No laser marking rotation.
Or:
Production location Wuxi/China:-> 180° laser marking rotation with underscore.
Note: Previous backend production location for above mentioned products might be phased out after customer approval of new location - without further information to customer
Description of change (1): Production location + Laser marking orientation
applicable for all products
Customer information package | OS QM CQM
OS-PCN-2020-013-A Introduction of Backend production location | 15.07.2020
5
OS-PCN-2020-013-A
Introduction of Backend production location Wuxi for
premolded detector products and other changes
Description of change (2): Leadframe type and Plating
only applicable for SFH 320G,
Current status
(previous location Penang)
New status
(new location Wuxi)
Front Side NiAu LDF on function area NiPdAu LDF on function area
Lead Side NiSn plating finish NiPdAu LDF without plating finish
Customer information package | OS QM CQM
OS-PCN-2020-013-A Introduction of Backend production location | 15.07.2020
6
OS-PCN-2020-013-A
Introduction of Backend production location Wuxi for
premolded detector products and other changes
Description of change (3): Harmonization of casting resin
only applicable for SFH 320G
Current status
(previous location Penang)
New status
(new location Wuxi)
Glas
transition
Temperat.
(Tg)
typ. 115°C typ. 135°C
No change in electro optical properties
Customer information package | OS QM CQM
OS-PCN-2020-013-A Introduction of Backend production location | 15.07.2020
7
List of affected products
OS-PCN-2020-013-A
Introduction of Backend production location Wuxi for
premolded detector products and other changes
SIDELED TOPLED
SFH 325 SFH 320
SFH 325 FA SFH 320 FA
SFH 325 FAG SFH 320G
Customer information package | OS QM CQM
OS-PCN-2020-013-A Introduction of Backend production location | 15.07.2020
8
OS-PCN-2020-013-A
Introduction of Backend production location Wuxi for
premolded detector products and other changes
PCN Samples
available
on request
SIDELED TOPLED
SFH 325 SFH 320
SFH 325 FA SFH 320 FA
SFH 325 FAG SFH 320G
Customer information package | OS QM CQM
OS-PCN-2020-013-A Introduction of Backend production location | 15.07.2020
9
Time schedule for PCN material (after implementation of change):
Final qualification report 15.07.2020
Samples available 15.07.2020
Intended Start of delivery 15.10.2020 *)
*) or earlier if released by customer and upon mutual agreement
Time schedule for Pre-PCN material(prior to implementation of change):
Last time order date (LTO) 15.11.2020 **)
**) expected approval date needs to be available at this time. Lead time and LTO quantity shall be mutually agreed between OSRAM OS and customer.
Last time delivery date (LTD) 15.02.2021 ***)
***) planned last date for delivery of products of current status
Note:
Pre-PCN material: Products of current status, means before implementation of the changes as described in the PCN.
PCN material: Products with implementation of the changes as described in the PCN.
OS-PCN-2020-013-A
Introduction of Backend production location Wuxi for
premolded detector products and other changes
www.osram-os.com
Thank you.
www.osram-os.com
Light is OSRAM
Qualification Report 200176C1
Subject Reliability test results for TOPLED SFH 320 & SFH 320 FA
according to OS-PCN-2020-013-A
Date 13.07.2020
Tested device SFH 320 FA, SFH 320 G
Brand (including sub brands) TOPLED
Applies to
SFH 320; SFH 320 FA
Qualification Report 200176C1
Page 2 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
Preconditioning according to Jedec Level II
Note: 1) SFH 320 G; Eval lot (Wuxi Production);
2) SFH 320 FA; Lot A, B: Eval lot (Wuxi Production); Lot C: Control lot (PEN Production)
3) SFH 320 G; Lot A, B, C: Eval lot (Wuxi Production); Lot D: Control lot (PEN Production)
Failure criteria: Electrical failures: Iceo (Vce = 20V) > 50nA
Optical failures: Ipce (Vce=5V; Ee=0,1mW/m2) absolute limit: ±20% max. and
∆%max - ∆%min> 20% Visual failures: broken or damaged package or leads, solderability <95% wetting
Conclusion: Devices fulfill the reliability requirements.
Test Performed Condition Duration Sample
Size
Failures
El. Opt. Vis
Resistance to soldering heat
(RTSH) JESD22-A113 Reflow soldering 260°C
3x
3x
1x261)
3x262)
0
0
0
0
0
0
High temperature reverse bias
(HTRB) JESD22-A108
TA = 100°C,
VCE =28V 1000h 4x263) 0 0 0
Temperature & humidity reverse
bias (T&HRB) JESD22A101
85°C/85%r.H.
Vce=28V 1000h 4x263) 0 0 0
Temperature & humidity reverse
bias (T&HRB) JESD22A101
40°C/93%r.H.
Vce=28V 1000h 3x262) 0 0 0
Temperature cycle
(TC) JESD22-A104 -40°C/+100°C 15min each extreme
500c
500c
1x261)
3x262)
0
0
0
0
0
0
Electrostatic Discharge
(HBM) ANSI/ESDA/
JEDEC JS-001
Human Body Model 2000V
2000V
1x101)
3x102)
0
0
0
0
0
0
Qualification Report 200176C1
Page 3 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
Disclaimer PLEASE CAREFULLY READ THE BELOW TERMS AND CONDITIONS BEFORE USING THE INFORMATION.
IF YOU DO NOT AGREE WITH ANY OF THESE TERMS AND CONDITIONS, DO NOT USE THE INFORMATION.
The Information contained in this Document does not constitute an independent warranty. The committed behavior is
described in the Product data sheet and/or further, mutually agreed specifications.
Distribution of part or all of the contents of this Document to any 3rd party in any form without the prior permission of
OSRAM Opto Semiconductors GmbH is prohibited except in accordance with applicable mandatory law.
Further explanations:
Data: The Data used in this Document consider the reliability test results under the mentioned driving conditions only.
For Product information on the maximum operating conditions and the OSRAM OS standard qualification profile please
refer to the Product data sheet or contact your local sales partner.
Conditions: The conditions for the generation of the Data are as follows:
1. The Data and curves shown in this Document are based on experiments carried out under laboratory conditions on a
random sample size of LED/IRED/Laser/Detector with readouts at discrete readout times (where applicable). Thus, the
Data above represent a limited number of production lots only and may differ between different assembly lots over time
(including chip or package changes). Thus, the behavior of the LED/IRED/Laser/Detector in the final application may
differ from the Data. The behavior of the LED/IRED/Laser/Detector at conditions or readout times deviating from those
stated above may not be deduced from the Data.
2. If applicable:
a) Extended driving conditions:
The tested driving conditions exceed the maximum limits stated in the Product data sheet. Therefore a reduced
lifetime or an accelerated degradation is expected. Failure limits noted in the Document refer to the testing
condition according to the OSRAM OS standard Product qualification profile and not to the actual testing
condition.
b) Extended testing duration:
The testing duration exceed the OSRAM OS standard qualification profile of the mentioned Product. Failure
limits noted in the Document refer to the testing duration according to the OSRAM OS standard Product
qualification profile and not to the actual testing duration.
c) Exceeding standard qualification conditions – (Product data sheet limits not affected):
The tested driving conditions exceed the OSRAM OS standard qualification profile of the mentioned Product.
Therefore a reduced lifetime or an accelerated degradation is expected. Failure limits noted in the Document
refer to the testing condition according to the OSRAM OS standard Product qualification profile and not to the
actual testing condition.
3. For long term operation additional failure modes of the chip or package can occur which are not shown in this
Document.
4. Possible differences in the thermal management of OSRAM OS and customer’s setup may lead to a different aging
behavior.
Qualification Report 200176C1
Page 4 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
RTSH Reflow-soldering
SFH 320 G
Qualification Report 200176C1
Page 5 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
RTSH Reflow-soldering
SFH 320 FA
Lot A
Lot B
Lot C
Qualification Report 200176C1
Page 6 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
HTRB 100°C/28V
SFH 320 G
Lot A
Lot B
Lot C
SFH 320G HTRB100°C/28V W19_01115_11I 26 pcs
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Readout [h]
0 200 400 600 800 1000
SFH 320G HTRB100°C/28V W19_01115_11I 26 pcs
-10
0
10
20
30
40
50
Readout [h]
0 200 400 600 800 1000
Qualification Report 200176C1
Page 7 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
Lot D
SFH 320G HTRB100°C/28V W19_01115_11G 26 pcs
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Readout [h]
0 200 400 600 800 1000
SFH 320G HTRB100°C/28V W19_01115_11G 26 pcs
-10
0
10
20
30
40
50
Readout [h]
0 200 400 600 800 1000
Qualification Report 200176C1
Page 8 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
T&HRB 85°C/85%r.H.; VCE=28V
SFH 320 G
Lot A
Lot B
Lot C
SFH 320G T&HRB85°C; r.H. = 85 %;28V W19_01115_10A 26 pcs
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Readout [h]
0 200 400 600 800 1000
SFH 320G T&HRB85°C; r.H. = 85 %;28V W19_01115_10A 26 pcs
-10
0
10
20
30
40
50
Readout [h]
0 200 400 600 800 1000
SFH 320G T&HRB85°C; r.H. = 85 %;28V W19_01115_10B 26 pcs
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Readout [h]
0 200 400 600 800 1000
SFH 320G T&HRB85°C; r.H. = 85 %;28V W19_01115_10B 26 pcs
-10
0
10
20
30
40
50
Readout [h]
0 200 400 600 800 1000
SFH 320G T&HRB85°C; r.H. = 85 %;28V W19_01115_10I 30 pcs
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Readout [h]
0 200 400 600 800 1000
SFH 320G T&HRB85°C; r.H. = 85 %;28V W19_01115_10I 30 pcs
-10
0
10
20
30
40
50
Readout [h]
0 200 400 600 800 1000
Qualification Report 200176C1
Page 9 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
Lot D
SFH 320G T&HRB85°C; r.H. = 85 %;28V W19_01115_10G 26 pcs
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Readout [h]
0 200 400 600 800 1000
SFH 320G T&HRB85°C; r.H. = 85 %;28V W19_01115_10G 26 pcs
-10
0
10
20
30
40
50
Readout [h]
0 200 400 600 800 1000
Qualification Report 200176C1
Page 10 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
T&HRB 40°C/93%r.H.; VCE=28V
SFH 320 FA
Lot A
Lot B
Lot C
Qualification Report 200176C1
Page 11 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
TC -40°C/100°C
SFH 320 G
Qualification Report 200176C1
Page 12 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
TC -40°C/100°C
SFH 320 FA
Lot A
Lot B
Lot C
Qualification Report 200176C1
Page 13 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
ESD HBM
SFH 320 G
SFH 320G ESDHBM W19_01115_7B 10 pcs
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Readout [V]
0 500 1000 1500 2000
SFH 320G ESDHBM W19_01115_7B 10 pcs
-10
0
10
20
30
40
50
Readout [V]
0 500 1000 1500 2000
Qualification Report 200176C1
Page 14 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
ESD HBM
SFH 320 FA
Lot A
Lot B
Lot C
Qualification Report 200176C1
Page 15 of 15 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
END OF DOCUMENT
OSRAM Opto Semiconductors
GmbH
Head Office:
Leibnizstrasse 4
93055 Regensburg, Germany
Phone +49 941 850-5
Fax +49 941 850-1002
www.osram-os.com
www.osram-os.com
Light is OSRAM
Qualification Report 200173C1
Subject Reliability test results for TOPLED SFH 320G according to
OS-PCN-2020-013-A
Date 13.07.2020
Tested device SFH 320G
Brand (including sub brands) TOPLED
Applies to
SFH 320G
200173C1
Page 2 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
Note: Lot A, B, C: Eval lot (Wuxi Production); Lot D: Control lot (PEN Production)
Pre-conditioning according to Jedec Level II AEC-Q102 #2
Test Performed Condition Duration Sample
Size
Failures
El. AEC-Q102 #1
Opt. AEC-Q102 #1
Vis AEC-Q102 #3
Temperature Cycling
TC JESD22-A104 AEC-Q102 #7
Test PCB: FR4
TA = -40°C/+100°C
15min each extreme 1000c 4x26 0 0 0
Electrostatic Discharge
HBM ANSI/ESDA/
JEDEC JS-001 AEC-Q102 #10a
Test PCB: FR4
Human Body Model 2000V 4x26 0 0 0
Temperature & humidity reverse bias
H³TRB JESD22-A101 AEC-Q102 #6c
Test PCB: FR4
TA = 85°C,
r.H.= 85%;
VCE = 28V
1000h 4x26 0 0 0
High temperature & reverse bias
HTRB JESD22-A108 AEC-Q102 #5c
Test PCB: FR4
TA = 100°C,
VCE = 28V 1000h 4x26 0 0 0
Electrostatic Discharge
CDM AEC-Q101-005 AEC-Q102 #10b
Charged Device Model -
CDM testing of small
packages under
evaluation
Vibration Variable Frequency
VVF JESD22-A103 AEC-Q102 #15
20g, 20-2000Hz;
4min / cy; 4cy/axis -
for uncasted packages
only Mechanical shock
MS JESD22-B104 AEC-Q102 #16
1500g; 5 blows
X12, Y12, Z12 -
Resistance to Solder Heat
RSH JESD22-A113 AEC-Q102 #18a
Test PCB: FR4
Reflow soldering
260°C 3x 4x26 0 0 0
Hydrogen Sulphide
H2S IEC 60068-2-43 AEC-Q102 #22
Test PCB: FR4
10ppm H2S
25°C/75%r.H. 336h 4x26 0 0 0
Flowing Mixed Gas
FMG IEC 60068-2-60 AEC-Q102 #23
Test PCB: FR4
TA = 25°C,
r.H.= 75%
Test method 4
500h 4x26 0 0 0
200173C1
Page 3 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
Failure criteria: Electrical failures: Iceo (Vce = 20V) > 50nA
Optical failures: Ipce (Vce=5V; Ee=0,1mW/m2) absolute limit: ±25% max. and
∆%max - ∆%min> 25% Visual failures: broken or damaged package or leads, solderability <95% wetting
Conclusion: The tested devices fulfill the reliability requirements of AEC-Q102.
200173C1
Page 4 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
Disclaimer PLEASE CAREFULLY READ THE BELOW TERMS AND CONDITIONS BEFORE USING THE INFORMATION.
IF YOU DO NOT AGREE WITH ANY OF THESE TERMS AND CONDITIONS, DO NOT USE THE INFORMATION.
The Information contained in this Document does not constitute an independent warranty. The committed behavior is
described in the Product data sheet and/or further, mutually agreed specifications.
Distribution of part or all of the contents of this Document to any 3rd party in any form without the prior permission of
OSRAM Opto Semiconductors GmbH is prohibited except in accordance with applicable mandatory law.
Further explanations:
Data: The Data used in this Document consider the reliability test results under the mentioned driving conditions only.
For Product information on the maximum operating conditions and the OSRAM OS standard qualification profile please
refer to the Product data sheet or contact your local sales partner.
Conditions: The conditions for the generation of the Data are as follows:
1. The Data and curves shown in this Document are based on experiments carried out under laboratory conditions on a
random sample size of LED/IRED/Laser/Detector with readouts at discrete readout times (where applicable). Thus, the
Data above represent a limited number of production lots only and may differ between different assembly lots over time
(including chip or package changes). Thus, the behavior of the LED/IRED/Laser/Detector in the final application may
differ from the Data. The behavior of the LED/IRED/Laser/Detector at conditions or readout times deviating from those
stated above may not be deduced from the Data.
2. If applicable:
a) Extended driving conditions:
The tested driving conditions exceed the maximum limits stated in the Product data sheet. Therefore a reduced
lifetime or an accelerated degradation is expected. Failure limits noted in the Document refer to the testing
condition according to the OSRAM OS standard Product qualification profile and not to the actual testing
condition.
b) Extended testing duration:
The testing duration exceed the OSRAM OS standard qualification profile of the mentioned Product. Failure
limits noted in the Document refer to the testing duration according to the OSRAM OS standard Product
qualification profile and not to the actual testing duration.
c) Exceeding standard qualification conditions – (Product data sheet limits not affected):
The tested driving conditions exceed the OSRAM OS standard qualification profile of the mentioned Product.
Therefore a reduced lifetime or an accelerated degradation is expected. Failure limits noted in the Document
refer to the testing condition according to the OSRAM OS standard Product qualification profile and not to the
actual testing condition.
3. For long term operation additional failure modes of the chip or package can occur which are not shown in this
Document.
4. Possible differences in the thermal management of OSRAM OS and customer’s setup may lead to a different aging
behavior.
200173C1
Page 5 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
TC -40°C/100°C
Lot A
Lot B
200173C1
Page 6 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
TC -40°C/100°C
Lot C
Lot D
200173C1
Page 7 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
HBM
Lot A
Lot B
200173C1
Page 8 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
HBM
Lot C
Lot D
200173C1
Page 9 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
H³TRB 85°C/85%r.H.; 28V
Lot A
Lot B
200173C1
Page 10 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
H³TRB 85°C/85%r.H.; 28V
Lot C
Lot D
200173C1
Page 11 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
HTRB 100°C/28V
Lot A
Lot B
200173C1
Page 12 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
HTRB 100°C/28V
Lot C
Lot D
200173C1
Page 13 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
RSH Resistance to Solder Heat
Lot A
Lot B
200173C1
Page 14 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
RSH Resistance to Solder Heat
Lot C
Lot D
200173C1
Page 15 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
H2S
Lot A
Lot B
200173C1
Page 16 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
H2S
Lot C
Lot D
200173C1
Page 17 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
FMG
Lot A
Lot B
200173C1
Page 18 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
FMG
Lot C
Lot D
200173C1
Page 19 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler
Reviewed by
C. Wensauer
Template revision
08.08.2018
END OF DOCUMENT
OSRAM Opto Semiconductors
GmbH
Head Office:
Leibnizstrasse 4
93055 Regensburg, Germany
Phone +49 941 850-5
Fax +49 941 850-1002
www.osram-os.com
www.osram-os.com
Light is OSRAM
Qualification Report 200175C1
Subject Reliability test results for SIDELED SFH 325 & SFH 325
FA according to OS-PCN-2020-013-A
Date 13.07.2020
Tested device SFH 325 FA
Brand (including sub brands) SIDELED
Applies to
SFH 325; SFH 325 FA
Qualification Report 200175C1
Page 2 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
Preconditioning according to Jedec Level II
Note: Lot A, B, C: Eval lot (Wuxi Production); Lot D: Control lot (PEN Production)
Failure criteria: Electrical failures: Iceo (Vce = 20V) > 50nA
Optical failures: Ipce (Vce=5V; Ee=0,1mW/m2) absolute limit: ±20% max. and
∆%max - ∆%min> 20% Visual failures: broken or damaged package or leads, solderability <95% wetting
Conclusion: The tested devices fulfill the reliability requirements.
Test Performed Condition Duration Sample
Size
Failures
El. Opt. Vis
Resistance to soldering heat
(RTSH) JESD22-A113 Reflow soldering 260°C 3x 4x26 0 0 0
High temperature reverse bias
(HTRB) JESD22-A108
TA = 100°C
VCE =28V 1000h 4x26 0 0 0
Temperature & humidity reverse bias
(T&HRB) JESD22A101
40°C/93%r.H.
Vce=28V 1000h 4x26 0 0 0
Temperature cycle
(TC) JESD22-A104 -40°C/+100°C 15min each extreme 1000c 4x26 0 0 0
Electrostatic Discharge
HBM ANSI/ESDA/
JEDEC JS-001 Human Body Model 2000V 4x26 0 0 0
Qualification Report 200175C1
Page 3 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
Disclaimer PLEASE CAREFULLY READ THE BELOW TERMS AND CONDITIONS BEFORE USING THE INFORMATION.
IF YOU DO NOT AGREE WITH ANY OF THESE TERMS AND CONDITIONS, DO NOT USE THE INFORMATION.
The Information contained in this Document does not constitute an independent warranty. The committed behavior is
described in the Product data sheet and/or further, mutually agreed specifications.
Distribution of part or all of the contents of this Document to any 3rd party in any form without the prior permission of
OSRAM Opto Semiconductors GmbH is prohibited except in accordance with applicable mandatory law.
Further explanations:
Data: The Data used in this Document consider the reliability test results under the mentioned driving conditions only.
For Product information on the maximum operating conditions and the OSRAM OS standard qualification profile please
refer to the Product data sheet or contact your local sales partner.
Conditions: The conditions for the generation of the Data are as follows:
1. The Data and curves shown in this Document are based on experiments carried out under laboratory conditions on a
random sample size of LED/IRED/Laser/Detector with readouts at discrete readout times (where applicable). Thus, the
Data above represent a limited number of production lots only and may differ between different assembly lots over time
(including chip or package changes). Thus, the behavior of the LED/IRED/Laser/Detector in the final application may
differ from the Data. The behavior of the LED/IRED/Laser/Detector at conditions or readout times deviating from those
stated above may not be deduced from the Data.
2. If applicable:
a) Extended driving conditions:
The tested driving conditions exceed the maximum limits stated in the Product data sheet. Therefore a reduced
lifetime or an accelerated degradation is expected. Failure limits noted in the Document refer to the testing
condition according to the OSRAM OS standard Product qualification profile and not to the actual testing
condition.
b) Extended testing duration:
The testing duration exceed the OSRAM OS standard qualification profile of the mentioned Product. Failure
limits noted in the Document refer to the testing duration according to the OSRAM OS standard Product
qualification profile and not to the actual testing duration.
c) Exceeding standard qualification conditions – (Product data sheet limits not affected):
The tested driving conditions exceed the OSRAM OS standard qualification profile of the mentioned Product.
Therefore a reduced lifetime or an accelerated degradation is expected. Failure limits noted in the Document
refer to the testing condition according to the OSRAM OS standard Product qualification profile and not to the
actual testing condition.
3. For long term operation additional failure modes of the chip or package can occur which are not shown in this
Document.
4. Possible differences in the thermal management of OSRAM OS and customer’s setup may lead to a different aging
behavior.
Qualification Report 200175C1
Page 4 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
RTSH Reflow-soldering
Lot A
Lot B
Qualification Report 200175C1
Page 5 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
RTSH Reflow-soldering
Lot C
Lot D
Qualification Report 200175C1
Page 6 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
HTRB 100°C/28V
Lot A
Lot B
Qualification Report 200175C1
Page 7 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
HTRB 100°C/28V
Lot C
Lot D
Qualification Report 200175C1
Page 8 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
T&HRB 40°C/93%r.H.; VCE=28V
Lot A
Lot B
Qualification Report 200175C1
Page 9 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
T&HRB 40°C/93%r.H.; VCE=28V
Lot C
Lot D
Qualification Report 200175C1
Page 10 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
TC -40°C/100°C
Lot A
Lot B
Qualification Report 200175C1
Page 11 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
TC 2 Chamber -40°C/100°C
Lot C
Lot D
Qualification Report 200175C1
Page 12 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
ESD HBM
Lot A
Lot B
Qualification Report 200175C1
Page 13 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
ESD HBM
Lot C
Lot D
Qualification Report 200175C1
Page 14 of 14 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
21.01.2015
END OF DOCUMENT
OSRAM Opto Semiconductors
GmbH
Head Office:
Leibnizstrasse 4
93055 Regensburg, Germany
Phone +49 941 850-5
Fax +49 941 850-1002
www.osram-os.com
www.osram-os.com
Light is OSRAM
Qualification Report 200174C1
Subject Reliability test results for SIDELED SFH 325 FAG
according to OS-PCN-2020-013-A
Date 13.07.2020
Tested device SFH 325 FAG, SFH 325 G
Brand (including sub brands) SIDELED
Applies to
SFH 325 FAG
200174C1
Page 2 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
Note: 1) SFH 325 FAG; Lot A: Eval lot (Wuxi Production); Lot B: Control lot (PEN Production)
2) SFH 325 G Lot A, B: Eval lot (Wuxi Production)
Pre-conditioning according to Jedec Level II AEC-Q102 #2
Test Performed Condition Duration Sample
Size
Failures
El. AEC-Q102 #1
Opt. AEC-Q102 #1
Vis AEC-Q102 #3
Temperature Cycling
TC JESD22-A104 AEC-Q102 #7
Test PCB: FR4
TA = -40°C/+100°C
15min each extreme
1000c
1000c
2x261)
2x262)
0
0
0
0
0
0
Electrostatic Discharge
HBM ANSI/ESDA/
JEDEC JS-001 AEC-Q102 #10a
Test PCB: FR4
Human Body Model 2000V
2000V
2x261)
2x262)
0
0
0
0
0
0
Temperature & humidity reverse bias
H³TRB JESD22-A101 AEC-Q102 #6c
Test PCB: FR4
TA = 85°C,
r.H.= 85%;
VCE = 28V
1000h
1000h
2x261)
2x262)
0
0
0
0
0
0
High temperature & reverse bias
HTRB JESD22-A108 AEC-Q102 #5c
Test PCB: FR4
TA = 100°C,
VCE = 28V 1000h 1000h
2x261)
2x262)
0
0 0
0 0
0
Electrostatic Discharge
CDM AEC-Q101-005 AEC-Q102 #10b
Charged Device Model - CDM testing of small
packages under evaluation
Vibration Variable Frequency
VVF JESD22-A103 AEC-Q102 #15
20g, 20-2000Hz;
4min / cy; 4cy/axis
for uncasted packages
only Mechanical shock
MS JESD22-B104 AEC-Q102 #16
1500g; 5 blows
X12, Y12, Z12
Resistance to Solder Heat
RSH JESD22-A113 AEC-Q102 #18a
Test PCB: FR4
Reflow soldering
260°C
3x
3x
2x261)
2x262)
0
0
0
0
0
0
Hydrogen Sulphide
H2S IEC 60068-2-43 AEC-Q102 #22
Test PCB: FR4
10ppm H2S
25°C/75%r.H.
336h
336h
2x261)
2x262)
0
0
0
0
0
0
Flowing Mixed Gas
FMG IEC 60068-2-60 AEC-Q102 #23
Test PCB: FR4
TA = 25°C,
r.H.= 75%
Test method 4
500h
500h
2x261)
2x262)
0
0
0
0
0
0
200174C1
Page 3 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
Failure criteria: Electrical failures: Iceo (Vce = 20V) > 50nA
Optical failures: Ipce (Vce=5V; Ee=0,1mW/m2) absolute limit: ±25% max. and
∆%max - ∆%min> 25% Visual failures: broken or damaged package or leads, solderability <95% wetting
Conclusion: The tested devices fulfill the reliability requirements of AEC-Q102.
200174C1
Page 4 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
Disclaimer PLEASE CAREFULLY READ THE BELOW TERMS AND CONDITIONS BEFORE USING THE INFORMATION.
IF YOU DO NOT AGREE WITH ANY OF THESE TERMS AND CONDITIONS, DO NOT USE THE INFORMATION.
The Information contained in this Document does not constitute an independent warranty. The committed behavior is
described in the Product data sheet and/or further, mutually agreed specifications.
Distribution of part or all of the contents of this Document to any 3rd party in any form without the prior permission of
OSRAM Opto Semiconductors GmbH is prohibited except in accordance with applicable mandatory law.
Further explanations:
Data: The Data used in this Document consider the reliability test results under the mentioned driving conditions only.
For Product information on the maximum operating conditions and the OSRAM OS standard qualification profile please
refer to the Product data sheet or contact your local sales partner.
Conditions: The conditions for the generation of the Data are as follows:
1. The Data and curves shown in this Document are based on experiments carried out under laboratory conditions on a
random sample size of LED/IRED/Laser/Detector with readouts at discrete readout times (where applicable). Thus, the
Data above represent a limited number of production lots only and may differ between different assembly lots over time
(including chip or package changes). Thus, the behavior of the LED/IRED/Laser/Detector in the final application may
differ from the Data. The behavior of the LED/IRED/Laser/Detector at conditions or readout times deviating from those
stated above may not be deduced from the Data.
2. If applicable:
a) Extended driving conditions:
The tested driving conditions exceed the maximum limits stated in the Product data sheet. Therefore a reduced
lifetime or an accelerated degradation is expected. Failure limits noted in the Document refer to the testing
condition according to the OSRAM OS standard Product qualification profile and not to the actual testing
condition.
b) Extended testing duration:
The testing duration exceed the OSRAM OS standard qualification profile of the mentioned Product. Failure
limits noted in the Document refer to the testing duration according to the OSRAM OS standard Product
qualification profile and not to the actual testing duration.
c) Exceeding standard qualification conditions – (Product data sheet limits not affected):
The tested driving conditions exceed the OSRAM OS standard qualification profile of the mentioned Product.
Therefore a reduced lifetime or an accelerated degradation is expected. Failure limits noted in the Document
refer to the testing condition according to the OSRAM OS standard Product qualification profile and not to the
actual testing condition.
3. For long term operation additional failure modes of the chip or package can occur which are not shown in this
Document.
4. Possible differences in the thermal management of OSRAM OS and customer’s setup may lead to a different aging
behavior.
200174C1
Page 5 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
TC -40°C/100°C
SFH 325 FAG
Lot A
Lot B
200174C1
Page 6 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
TC -40°C/100°C
SFH 325 G
Lot A
Lot B
200174C1
Page 7 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
HBM
SFH 325 FAG
Lot A
Lot B
200174C1
Page 8 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
HBM
SFH 325 G
Lot A
Lot B
200174C1
Page 9 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
H³TRB 85°C/85%r.H.; 28V
SFH 325 FAG
Lot A
Lot B
200174C1
Page 10 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
H³TRB 85°C/85%r.H.; 28V
SFH 325 G
Lot A
Lot B
200174C1
Page 11 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
HTRB 100°C/28V
SFH 325 FAG
Lot A
Lot B
200174C1
Page 12 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
HTRB 100°C/28V
SFH 325 G
Lot A
Lot B
200174C1
Page 13 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
RSH Resistance to Solder Heat
SFH 325 FAG Lot A
Lot B
200174C1
Page 14 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
RSH Resistance to Solder Heat
SFH 325 G Lot A
Lot B
200174C1
Page 15 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
H2S
SFH 325 FAG Lot A
Lot B
200174C1
Page 16 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
H2S
SFH 325 G Lot A
Lot B
200174C1
Page 17 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
FMG
SFH 325 FAG Lot A
Lot B
200174C1
Page 18 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
FMG
SFH 325 G Lot A
Lot B
200174C1
Page 19 of 19 Department
OS QM CQM ICI
Performed by
Dr. D. Fiedler (signed)
Reviewed by
C. Wensauer (signed)
Template revision
08.08.2018
END OF DOCUMENT
OSRAM Opto Semiconductors
GmbH
Head Office:
Leibnizstrasse 4
93055 Regensburg, Germany
Phone +49 941 850-5
Fax +49 941 850-1002
www.osram-os.com
NotifID NotifNumber NotifName ReleaseDate ResponseDueDate
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
1151 OS-PCN-2020-013-A Introduction of Backend 15-Jul-20 20-Aug-20
ImplementDate ProdAffected QNbr QNbrDesc QNbrDesc_Z1 Status
15-Okt-20 SFH 320 Q65110A2469 SFH 320-3-Z SFH 320-3-Z 10
15-Okt-20 SFH 320 Q65110A2471 SFH 320-Z SFH 320-Z 10
15-Okt-20 SFH 320 Q65110A2509 SFH 320-3/4 R33-Z SFH 320-3/4-Z 10
15-Okt-20 SFH 320 Q65110A2510 SFH 320-4-Z SFH 320-4-Z 10
15-Okt-20 SFH 320 FA Q65110A1836 SFH 320 FA-4-Z SFH 320 FA-4-Z 10
15-Okt-20 SFH 320 FA Q65110A2472 SFH 320 FA-Z SFH 320 FA-Z 10
15-Okt-20 SFH 320 FA Q65110A2507 SFH 320 FA-3 R33-Z SFH 320 FA-3-Z 10
15-Okt-20 SFH 320 FA Q65110A2508 SFH 320 FA-3/4 R33-Z SFH 320 FA-3/4- 10
15-Okt-20 SFH 320 FA Q65110A2511 SFH 320FA-3/4 E9544-Z SFH 320FA-3/4 10
15-Okt-20 SFH 320 FA Q65111A0002 SFH 320 FA-4 R33-Z SFH 320 FA-4 10
15-Okt-20 SFH 320G Q65110A6837 SFH 320G-3-Z SFH 320G-3-Z 10
15-Okt-20 SFH 320G Q65110A6838 SFH 320G-4-Z SFH 320G-4-Z 10
15-Okt-20 SFH 320G Q65110A6839 SFH 320G-3/4-Z SFH 320G-3/4-Z 10
15-Okt-20 SFH 325 Q65110A2484 SFH 325-4-Z SFH 325-4-Z 10
15-Okt-20 SFH 325 Q65110A2486 SFH 325-Z SFH 325-Z 10
15-Okt-20 SFH 325 Q65110A2488 SFH 325-3-Z SFH 325-3-Z 10
15-Okt-20 SFH 325 Q65110A2491 SFH 325-3/4-Z SFH 325-3/4-Z 10
15-Okt-20 SFH 325 FA Q65110A2482 SFH 325 FA-3-Z SFH 325 FA-3-Z 10
15-Okt-20 SFH 325 FA Q65110A2485 SFH 325 FA-4-Z SFH 325 FA-4-Z 10
15-Okt-20 SFH 325 FA Q65110A2487 SFH 325 FA-Z SFH 325 FA-Z 10
15-Okt-20 SFH 325 FA Q65110A2490 SFH 325 FA-3/4-Z SFH 325 FA-3/4- 10
15-Okt-20 SFH 325 FA Q65110A3506 SFH 325 FA -3/4A-Z SFH 325 FA - 10
15-Okt-20 SFH 325 FA Q65111A6157 SFH 325FA-3B4B-XX SFH 325FA- 10
15-Okt-20 SFH 325 FAG Q65110A6841 SFH 325 FAG-3/4-Z SFH 325 FAG- 10
15-Okt-20 SFH 325 FAG Q65110A6842 SFH 325 FAG-Z SFH 325 FAG-Z 10
15-Okt-20 SFH 325 FAG Q65111A2812 SFH 325 FAG-4-Z SFH 325 FAG-4- 10