36
Issued 03 / 03 Operating Instructions and Spare Parts List OptiTronic Powder Gun Control (CG03) E Before using this equipment, carefully read all instructions in this manual. Keep this Manual for future reference! IMPORTANT

OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

31OptiTronic CG03

Issu

ed 0

3 / 0

3

Operating Instructions and Spare Parts List

OptiTronic

Powder Gun Control

(CG03)

E

Before using this equipment, carefullyread all instructions in this manual.Keep this Manual for future reference!

IMPORTANT

Page 2: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

32

Page 3: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

33OptiTronic CG03

Issu

ed 0

3 / 0

3

(continued)

Table of Contents

Safety rules for electrostatic powder coating operations

Technical Data

OptiTronic type definition and possible Options

OptiTronic powder gun control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1About these operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

OptiTronic control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Field of application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2The basic OptiTronic unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2CG 03 OptiTronic Version Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Plug and socket connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Description of functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Special functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Entering the special functions mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Exiting special functions mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7System parameter selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7System parameter table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Resetting the throttle motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Throttle Motors - Conveying air, Supplementary air, Rinsing air . . . . . . . . . . . . . 10Powder output correction mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Carrying out a powder output correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Starting position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Example of a Powder output correction table. . . . . . . . . . . . . . . . . . . . . . 13

Software version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

System reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Fault message table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Operating mode - Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Guide Values - Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18General conditions for PI 3 / EasyFlow Injectors . . . . . . . . . . . . . . . . . . . . . . . . . 18Guide values for OptiTronic with PI 3 / EasyFlow Injectors . . . . . . . . . . . . . . . . . 18Spray Current Limiting Guide Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Manual Coating with EasySelect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Remote Control from the gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Pin allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Main power supply cable socket 2.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Socket 2.2 - Gun 2 (EasySelect / OptiGun 1 powder gun plug) . . . . . . . . . . . . . . 20Socket 2.3 - Gun 1 (GA02 OptiGun 2 / PG 1 / PG 1-A /PG 2-A powder gun plug) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Page 4: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

34

TABLE OF CONTENTS (CONTINUED)

Electrical Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Block diagram: OptiTronic Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Block diagram: Connections to Main Board (1) - OptiTronic Control Unit . . . . . . 22Block diagram: Connections to Main Board (2) - OptiTronic Control Unit . . . . . . 23

Pneumatic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24OptiTronic Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Spare parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Ordering spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25OptiTronic Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26OptiTronic control unit - complete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Pneumatics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Page 5: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

35OptiTronic CG03

Issu

ed 0

3 / 0

3

SAFETY RULES FOR ELECTROSTATIC POWDER COATING OPERATIONS

1. This equipment is dangerous when not operated according to thefollowing standards:EN 50 050 (or VDE 0745, Part 100), EN 50 053, Part 2 (or VDE0745, Part 102) and the Specification Sheet ZH 1/443 for electro-static powder coating.

2. All electrically conductive parts located within 5 m of the coatingarea and especially the workpieces must be properly grounded.

3. The floor in the coating area must be electrically conductive.Normal concrete is generally conductive.

4. The operating personnel must wear electrically conductivefootwear (e.g. leather soles).

5. The operating personnel should hold the gun in the bare hand. Ifgloves are worn, they must be electrically conductive.

6. Connect the grounding cable (yellow/green) supplied to thegrounding terminal on the control module. The grounding cablemust have a good metal to metal connection with the coatingbooth, recovery unit, and the workpiece conveyor system,especially with the workpiece suspension.

7. The electrical, and powder feed lines to the guns must be laid outso that they are protected from possible mechanical damage.

8. The powder coating equipment should only be switched on afterthe booth is in operation. If the booth breaks down then thepowder coating equipment must also switch off.

9. Check the grounding of all electrically conductive parts at leastonce a week.

10. When cleaning the gun or changing nozzles the control modulemust be switched off.

Page 6: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

36

OPTITRONIC TYPE DEFINITION AND POSSIBLE OPTIONS(see Control unit rear wall)

TECHNICAL DATA

Example:Label with Version number and Order number: V 2 386 162

(see Version table)

OPTITRONIC - BASIS MODEL

Mains connection:Input voltage: 90-264 VACPower consumption: 48 VAFrequency: 47-463 HzType of protection: IP54Temperature range: 0° C to +40° C

(+32° F to +104° F)

Pneumatic data:Input pressure: 5.0 barMax. water vapour content: 1.3 g/m3

Max. oil vapour content: 0.1 mg/kg (Oil/Water)

Max. compressed air consumption: 11 m3/h

Dimensions:Width: 203 mmHeight: 174 mmDepth: 222 mmWeight: 4.8 kg

Attachable electrostatic guns:Nominal output voltage: 12 V (G2 guns)•

10 V (G1 guns)‡

Automatic guns: PG 1-A‡ / PG 2-A‡ /GA 01 OptiGun 1• / GA02OptiGun 2‡

Manual guns: PG 1‡ / GM 01 EasySelect•

Tribo guns: Connection possible

ABBREVIATIONS:

FL Conveying airZL Supplementary air‡G1 GA 02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Guns•G2 GA 01 OptiGun 1 / GM 01 EasySelect Guns

Page 7: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

1OptiTronic CG03

Issu

ed 0

3 / 0

3

OPTITRONIC POWDER GUN CONTROL

ABOUT THESE OPERATING INSTRUCTIONS

These operating instructions contain all important information which isrequired to operate your OptiTronic powder coating equipment.It will guide you safely through the installation stage, give you notesand tips for the optimum use of your new powder coating equipment.Information about the functioning of individual system components willbe found in the respective documentation.

Abbreviations used in these Operating Instructions:

EL Electrode rinsing airFL Conveying airFL_min Minimum powder outputGL Total air volumeHV_BG High-voltage settingI_BG Current settingPA% Powder output (percent)SKW% Powder output correction valueZL Supplementary air

Page 8: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

2

The OptiTronic Control Unit was designed to meet the special require-ments of job coaters.

OPTITRONIC CONTROL UNIT

THE BASIC OPTITRONIC UNIT

The OptiTronic Control Unit is a complete control unit for one powdergun.The concept of the OptiTronic control unit permits the operator to adapthis individual solution requirements to his individual applications.The control electronics, based on a micro-controller, makes it possibleto expand the functions, with corresponding electronic modules, at anytime.The basic equipment contains all the control and monitoring functionsrequired to operate a manual or an automatic powder gun.See the Version tables to determine the equipment version, and forexpanding existing equipment (Retrofitting) to another version.All coating parameters (desired values and actual values) have theirindividual display and input unit to give the highest user-friendly opera-tion.Up to 255 coating programs can be stored and instantly recalled.The stored programs help considerably to increase the repeatability ofuniform coating results and quality, at any time, independent of theoperator and type of powder used.The powder volume is set independent from the total air volume. Theallotment of the conveying air and supplementary air takes placeautomatically.With freely selectable high-voltage or spraying current optimum high-voltage generation is guaranteed, also for the highest applicationdemands.Various diagnostic functions, indicated through LEDs and seven seg-ment displays, increase the process reliability and make operationeasier.

The most important characteristics of the OptiTronic are:

• 255 stored coating programs possibleA coating program is composed of:

- High-voltage (kV)- Spraying current (µA)- Electrode rinsing air (Nm3/h)- Powder output (%)- Total air volume (Conveying air + Supplementary air - Nm3/h)

• Individual inputs, and display windows for high-voltage, sprayingcurrent, electrode rinsing air, powder output, total air volume, andprograms.

• High-voltage or spraying current setting• Diagnostic functions

FIELD OF APPLICATION

Page 9: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

3OptiTronic CG03

Issu

ed 0

3 / 0

3

Version OptiTronic G1• G2*

Order No.

1 384 640 X

2 386 162 X

• G1 = GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A* G2 = GA01 OptiGun 1 / GM 01 EasySelect

CG 03 OPTITRONIC VERSION TABLE

Page 10: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

4

PLUG AND SOCKET CONNECTIONS

1.1 IN

5 bar73 PSI

1.3

1.2

1.4

The OptiTronic control unit is ready for use from the factory.Only certain cables and hoses must be connected by the customer.

The hose for the compressed air supply from the compressedair circuit is connected directly to the main air connection - 1.1 IN onthe rear of the control unit

The red hose for the conveying air is connected to the correspondingoutput - 1.2 on the rear of the control unit and to the injector.

The black hose for the supplementary air is connected to the corre-sponding output - 1.3 on the rear of the control unit and to the injector.

The hose for the rinsing air is connected to the electrode rinsing airoutput -1.4 and on the powder gun.

(continued)

The grounding connection cable is connected to the control unit withthe grounding screw, and the 5 m long grounding cable with the clamp-ing clip on the booth or on the hanger device.

NOTICEThe main compressed air input pressureinput pressureinput pressureinput pressureinput pressure must be set at 5.0 bar5.0 bar5.0 bar5.0 bar5.0 bar.The compressed air must be free from oil and water.

Figure 1

Mains connection

Gun 1

1.1 IN

5 bar73 PSI

2.1

1.31.4

2.3

Gun 2

2.2

1.2

Input voltage:

Input power:

Degree of protection:

Gun 1

Output:

Corresponding guns:

Gun 2

Output:

Corresponding guns:

100-240 VAC 50/60 Hz

48 VA

IP 54

10 V 17 kHz 1,2 A

PG 1-A PG 2-A PG 1

12 V 1,0 A

GA01 OptiGun

GM01 EasySelect

OptiTronic Type CG 03

F22,0 AT

F12,0 AT

Mains switch

Page 11: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

5OptiTronic CG03

Issu

ed 0

3 / 0

3

Mains connection - 2.1 - The Main power supply cable is connected tothe socket.

Gun 2 - 2.2 (Automatic Powder Gun OptiGun 1 / Manual Powder GunEasySelect - Alternatively). The gun cable plug is connected to thesocket with a 6 pin plug.

Gun 1

2.3

PLUGS AND SOCKETS (CONTINUED)

Mains connection

2.1

Gun 2

2.2

1

2

3PE

or

Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A PowderGuns - Alternatively) The gun cable plug is connected to the socket witha 7 pin plug.

Page 12: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

6

DESCRIPTION OF FUNCTIONS

Each of the coating parameters of the OptiTronic control unit has itsown display and its own operating area.

The Fault Diagnostic LEDs indicate certain equipment faults.The OptiTronic control unit is functioning correctly when the Diagnostic LEDs

1, 2, 3, and 4 are illuminated (green).

If any of the Diagnostic LEDs do not illuminate, please contact an ITW

Gema Service Centre.

Functions of the Diagnostic LEDs:1: +24 V DC internal power supply present - green

2: +15 V DC Internal power supply present - green

3: +5 V DC Internal power supply present - green4: Main solenoid valve operating - green

The equipment is activated or deactivated with the Main Key pad.When the control is active the green OptiTronic LED (lower left) is illuminated.In addition, if the green System LED (upper left) is illuminated the equipmentis released by external control and coating can be started.

- kV window for display and setting of High-voltage output(Setting range: 0-100 kV).

- µA window for display and setting of Spray current output(Setting range: 0-100 µA).

- Electrode rinsing air window for display and setting of the elec-trode rinsing air output.(Setting range: 0-2.8 m3/h. Default value 0.2 Nm3/h).The Select key pad is used for Swirl Air.(Setting range: 0-6.2 Nm3/h. Default value: 2.0 Nm3/h)

- Powder output window for display and setting of the powderoutput (Setting range: 0-100 %).

- Total air volume window for display and setting of the totalair volume (Setting range: 1.8-8.0 Nm3/h).

- Program Number window for display and setting of the programnumber (Setting range: 1-255), as well as Fault message display andFault message acknowledgement.

This LED (red) illuminates when there is a fault in the high-voltage system.

This LED (red) illuminates when there is a fault in the pneumatic system.

This LED (green) - Remote is not used.

Page 13: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

7OptiTronic CG03

Issu

ed 0

3 / 0

3

SPECIAL FUNCTIONS

Special functions are:1. System parameter selection2. Throttle motor referencing3. Powder output correction4. Software version

Special functions can be activated after entering the Special Functionmode, see below, by pressing any + or – key in the correspondingdisplay area.

ENTERING THE SPECIAL FUNCTIONS MODE

Press the Main key pad (for approx. 10 secs) until the display no longerilluminates.

All the green Diagnostic LEDs should illuminate.If not, see "Description of Functions - Fault Diagnostic LEDs"

SYSTEM PARAMETER SELECTION

The Special Functions mode can be exited by pressing the Main Key

pad. The switch-on counter will automatically reset to 30 when exitingthe Special functions mode, irrespective of the number of times thecontrol unit was switched on previously. The next time the control unitis switched on an automatic throttle motor referencing will take place.

EXITING SPECIAL FUNCTIONS MODE

1. Press the Main Key pad (for approx. 10 secs) until the display nolonger illuminates.

2. The System Parameter mode is entered by pressing any + or –key in the kV or µA display area.

3. Select the system parameter (P00-P08/PE/PL) with the + or –key.

4. Change the system parameter value with the + or – key.(see System Parameter Table).After the System parameters are reset, the throttle motors arealso referenced when exiting the Special Functions mode.

5. The Special Functions mode can be exited by pressing the Main

Key pad.

Page 14: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

8

Description

Option:FlowControl

Gun type

Swirl air

Injector type

Gun deselection(OptiTronic Key)

System Signal

Communication

Values

(The bold numbers [0 or 1etc.] in this column aredefault values)

0: Basic setting

0: Gun type - OptiGun 2 / PG1: Gun type - EasySelect

- OptiGun 12: Tribo Gun type

0: Basic setting

(Nozzle ø in mm) FL ZL0: PI 3 = 1.6 1.41: PI 3 = 1.8 1.42: PI 3 = 2.0 2.03: EasyFlow = 1.6 1.4

0: Basic setting

0: Automatic equipment,External system signal inmanual and remoteoperation necessary

1: Internal System releaseNo external signal neces-sary (Demo Unit only)

2-4: Not used

0: Basic setting

SYSTEM PARAMETER TABLE

Remarks

Select gun type.- Control unit does not react

to incorrect setting input.- No kV value displayed in

normal mode

Select injector type, e.g.:- ø 1.6 mm - with notch.- ø 1.8 mm - without notch.Match the injector nozzle(FL), and throttle (ZL) withthe corresponding injector.

Parameter (P00-P08/PE/PL)

Value

Abbreviations used on these pages:EL = Electrode rinsing airFL = Conveying airGL = Total airPA% = Powder output (in percent)ZL = Supplementary air

Parameter

number

P0:

P1:

P2:

P3:

P4:

P5:

P6:

(continued)

Page 15: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

9OptiTronic CG03

Issu

ed 0

3 / 0

3

Parameter

numberDescription Values

(The bold numbers [0 or 1etc.] in this column aredefault values)

Remarks

SYSTEM PARAMETER TABLE (CONTINUED)

P7:

P8:

P9:

PE:

PL:

Display variant

Not used

Not used

Not used

Not used

Standard display.Display of individual air

volumes FL and GL forchecking purposes

0: = PA%, = GL m3/h1: = FL m3/h, =GLm3/h

0: Basic setting

5: Basic setting

3: Basic setting

1: Basic setting

Page 16: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

10

RESETTING THE THROTTLE MOTORS

1. Enter the Special function mode by pressing the Main Key pad

(for approx. 10 secs) until the display no longer illuminates.

2. The throttle motors can be reset (Zero setting for conveying air[FL], supplementary air [ZL], electrode rinsing air [EL]). The throt-tle motor reset is initiated by pressing the + key or – key of the display window.

The throttle motor reset is made at the first Start-up, after servicing orafter application problems

3. Pressing a key once shows the number of times the main powersupply has been switched on since the last throttle motor reset.The diode on the lower right, below the display window blinks.The throttle motor reset is activated by pressing the + or – key asecond time. There should be three fairly loud noises, one foreach motor, one after the other. The display returns to 00.Switch-on counterIf the control unit is switched on 30 times and throttle motorreferencing has not been done within this number of times, athrottle motor referencing will take place automatically.The counter will reset to zero.

4. The Special Functions mode can be exited by pressing the Main

Key pad.

(continued)ABBREVIATIONS:EL Electrode rinsing airFL Conveying air

FL_min Minimum powder outputSKW% Powder output correction valueZL Supplementary air

IMPORTANT

THROTTLE MOTORS - CONVEYING AIR, SUPPLEMENTARY AIR, RINSING AIR

The throttle motors must be calibrated after every manual change. (see Resettingthe throttle motors, and Electrical Block diagram).

If the cable connections of the throttle motors are disconnected, caremust be take to see that the cables are marked for the correct recon-nection on the Main board (see also "Electrical diagrams)

- X11 Conveying air- X12 Supplementary air- X13 Rinsing air

POWDER OUTPUT CORRECTION MODE

The OptiTronic control unit makes possible the accommodation of thediffering powder outputs in the plant caused by differing powder hoselengths and geometry to the individual guns. The minimum powderoutput (FL_min) and the maximum powder output (SKW%) can beaccommodated for with two parameters.

Page 17: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

11OptiTronic CG03

Issu

ed 0

3 / 0

3

Powder output correction is made at the first Start-up, after servicing,after application problems or when hoses with a different diameter tothat used previously.

POWDER OUTPUT CORRECTION MODE (CONTINUED)

To enter the Powder Output Correction mode, press the Main Key pad

(for approx. 10 secs) until the display no longer illuminates.

1. The value for minimum powder output (FL_min) is set with the +or – keys in the display window.

2. The Output correction value for the maximum powder output(SKW%) is set with the + or – keys in the display window.

3. The Special Functions mode can be exited by pressing the Main

Key pad.

CARRYING OUT A POWDER OUTPUT CORRECTION

The settings in the following example are carried out on each gunindividually.Powder output correction is made at the first Start-up, after servicing,after application problems or when hoses with a different diameter tothat used previously.

Create a table with an entry for each powder gun similar to that illus-trated in section "Example of a table for powder output correction" Thetable will be useful after a System Reset.

The following table contains values which can be used for setting upthe OptiTronic Powder Control Unit

Total air volume (Nm3/h) 5Correction value

FL_ min 1.8SKW% 100

ABBREVIATIONS:FL Conveying airSKW% Powder output correction value

Page 18: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

12

4. Set the powder output value (FL_min) for minimum powderoutput 1.8 (Nm3/h) in the display window.

5. Set the Powder output correction value (SKW%) for a maximumpowder output to 100 % in the display window.

Exit the Special Function mode by pressing the Main Key pad.

For the next steps a measuring bag is necessary for weighing thepowder output. If possible, one bag should be used for each gun.Note the weight of the individual measuring bag.

6. Place the neck of the empty measuring bag tightly over thepowder gun nozzle so that it does not slide off during the measur-ing and switch on the powder gun for 60 seconds.

7. After the time has elapsed, switch off the gun and remove andweigh the bag. The weight of the powder should be between10-15 g.

ABBREVIATIONS:FL Conveying airSKW% Powder output correction value

(continued)

1. Select program number 001 in the Program display window.

STARTING POSITION

2. Set the total air volume to 5.0 Nm3/h in the display window, ifnot already set to this value.Set the powder output to 00 (%) in the display window.

3. Switch to the Special Functions mode by pressing the Main Key

pad (for approximately 10 seconds) until the display no longerilluminates.

8. If no powder is expelled from the gun, return to the SpecialFunctions mode and increase the powder output to between1.8-2.4 (Nm3/h) for a minimum powder output.

9. Repeat Steps 6 and 7 until the weight of the powder output iswithin 10-15 g. Note the minimum powder output value FL_min

in the table.

Page 19: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

13OptiTronic CG03

Issu

ed 0

3 / 0

3

10. Exit the Special Functions mode by pressing the Main Key pad.

11. Now set the powder output to 80 (%) in the display window.12. Place the empty measuring bag tightly over the powder gun

nozzle and switch on the powder gun for 60 seconds.13. Switch off the gun after 60 seconds. Weigh the bag.14. Enter the value of the maximum powder output (g/min) in the

table.Calculate the powder output correction according to the formula:

ABBREVIATIONS:

FL_min Minimum powder output airSKW% Powder output correction value

SKW% =smallest powder output

measured powder outputx 100

15. Fill in the calculated value in the table and then repeat the step 3for setting the corresponding SKW% value in the displaywindow on the control unit.

STARTING POSITION (CONTINUED)

Gun Powder output Powder outputcorrection w/o correction

No. FL_min SKW Powder output(Nm3/h) (%) at 80 %

1 1.7 100 % 200 g/min.2 1.8 (200/250) · 100 = 80 % 250 g/min.3 2.6 (200/280) · 100 = 71 % 280 g/min.

Gun n

EXAMPLE OF A POWDER OUTPUT CORRECTION TABLE.

SOFTWARE VERSION

1. To determine the Software Version, press the Main Key pad (forapprox. 10 secs) until the display no longer illuminates.

2. The software version is called up by pressing the + or – keys ofthe Program display.

3. The software version number of the OptiTronic operating programis displayed.

4. The Special Functions mode can be exited by pressing the Main

Key pad.

Page 20: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

14

CAUTION

ABBREVIATIONS:

FL_min Minimum powder output airSKW% Powder output correction value

A System Reset is initiated at the first Start-up, and at function fault.

SYSTEM RESET

A System Reset over-writes all 255 programs with default values and the systemparameters are returned to their original factorysettings.

1. Switched off the OptiTronic control unit with the Main power

switch on the control cabinet. Do not switch off the booth etc.2. Hold the Main Key pad pressed and switch on the Main power

switch. After approximately 15 seconds the actual programnumbers 001-255 appear in the Program display window and theprograms are individually reset to the factory default values. TheMain Key pad only has to be pressed until the program numbersstart to run through in rapid succession in display window.Fault diagnostic LED 4 is OFF during a ResetAfter a System Reset the system parameters must be checkedthat they are correct.

Page 21: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

15OptiTronic CG03

Issu

ed 0

3 / 0

3

Air Supply

H01

H02(only whenFlowControl isfitted)

H03(only whenFlowControl isfitted)

H04

H05

H06

H07

H08

H09

High-voltage

H10

H11

Fault description

Check system parameter P0 and set P0 = 0 on the basis control withoutFlowControl

Check system parameter P0 and set P0 = 0 on the basis control withoutFlowControl

Check system parameter P0 and set P0 = 0 on the basis control

EL 1 Solenoid valve error, set System parameter P5 = 0 for Automaticequipment. P5 = 1 for Demo equipment.

The desired Total Air is too little. Increase the programmed value for theTotal Air or make the FL_min of the powder output correction smaller

Main solenoid valve fault.Connection cable from the main solenoid valve to the basic electronics

missing.Check the main solenoid valve.

The desired supplementary air volume is too large (ZL_max.).Decrease the programmed value for the total air volume and/or increase the

programmed value for the powder output volume.

The desired conveying air volume is too large (FL_max.).Decrease the programmed value for the total air volume and/or decrease the

programmed value for the powder output volume.

The Daily Correction Value multiplied with the desired value of the powderoutput is greater than 100 %. (Acknowledge error and decrease the DailyCorrection Value via the PLC)

Cascade produces a too high voltage.Check the basic electronics and gun

Check the system parameter P1 (Gun type)Check the gun cable for breaks.Replace gun.

FAULT MESSAGE TABLE

Fault code No.When a fault is present in the system the cause must beeliminated before further operation is possible.When the fault has been eliminated, this is acknowledgedby pressing the + or – key of the Program display

(continued)

Page 22: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

16

General Faults

H19

H20

H21

H22

H23

H24

EL 2 Solenoid valve error (not used).

Check the 24 V DC internal Power supply. The 24 V DC voltage is higherthan the nominal voltage - 24 V DC +10 %

Check the 24 V internal DC Power supply. The 24 V DC voltage is lowerthan the nominal voltage - 24 V DC -10 %

Fault in the 15 V DC power supply to basic electronics.Contact an ITW Gema Service Centre.

EEPROM fault. Contact an ITW Gema Service Centre.

EEPROM writes Timeout. Contact an ITW Gema Service Centre.

Air Supply Fault description

FAULT MESSAGE CODE (CONTINUED)

Page 23: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

17OptiTronic CG03

Issu

ed 0

3 / 0

3

SYSTEM RELEASE AND POWDER COATING

For technical safety reasons the OptiTronic control unit should only bereleased after fulfilling all the required safety conditions (e.g. Fireprotection etc.). The release is activated through the „2.1 Mains con-nection„ input.

Connection No. 3: System release -LED "System" illuminates green.

Input voltage: 90-264 VAC

The OptiTronic is ready for powder coating when:

a) The equipment is selected: LED "OptiTronic" illuminates (green)

b) Control voltage for System Release is present: LED "System" illuminates (green)

c) - Automatic gun connected: Powder output- Manual gun connected: Trigger pulled - Powder

CAUTION

DEMO UNIT

The control unit can be used as a "stand alone" unit for coating indi-vidual parts or small series. So that the equipment receives a systemrelease in this function (compare above), the parameter mode of "P5" isset to "1". Because of this, the Demo unit does not have to have anexternal control voltage present for system release.

The System parameter P5 must nevernevernevernevernever be set to "1" in a complete powder coatingplant, otherwise the powder guns will be switched on unintentionally!

Mains connection

2.1

1

2

3PE

Page 24: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

18

High-voltage with SuperCorona without SuperCorona

100 kV Flat parts: 50 µA (± 20) Flat parts: 15 µA (± 10)

100 kV Profiles: 60 µA (± 10) Profiles: 25 µA (± 5)

100 kV Spray-over: 20 µA (± 10) Spray-over: 5 µA (± 5)

Total air 4 Nm3/h 5 Nm3/h 6 Nm3/h

Powder output [g/min]

Powder output [%] 10 30 35 45

20 60 75 90

30 85 100 120

40 110 130 150

50 130 160 175

60 150 180 210

70 175 200 235

80 200 240 270

90 215 260

100 235 290

All values in these tables are guide values. Different ambient condi-tions, wear, and different types of powder can alter the values in thetables.

GUIDE VALUES - APPLICATION

GUIDE VALUES FOR OPTITRONIC WITH PI 3 / EASYFLOW INJECTORS

GENERAL CONDITIONS FOR PI 3 / EASYFLOW INJECTORS

Powder type: Epoxy/Polyester

Powder output [m] 10

Powder hose ø [mm] 11

Input pressure [bar] 5.0

Conveying air nozzle ø - PI 3 / EasyFlow [mm] 1.6

Supplementary air nozzle ø - PI 3 / EasyFlow [mm] 1.4

SPRAY CURRENT LIMITING GUIDE VALUES

Spraying current limiting enables:- achievement of greater stability in the coating process.- greater reproducibility, where only the High-voltage varies.- constant current values.

µA window for display and setting of the Spray current output with the+ or – keys (Setting range: 0-100 µA).

Page 25: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

19OptiTronic CG03

Issu

ed 0

3 / 0

3

MANUAL COATING WITH EASYSELECT

REMOTE CONTROL FROM THE GUN

Various functions are remotely controlled with the aid of the + and -keys on the rear of the gun:

Select the application settings - Programs 001 to 0031. Press the + and - keys on the gun simultaneously.

Press 1x = Prog. no. 1 LED: redPress 2x = Prog. no. 2 LED: greenPress 3x = Prog. no. 3 LED: red/green blinking

(approx. 1 Hz)Set with OptiTronic control:Program no. 4-255 LED: red/green blinking

(approx. 2 Hz)Check by observing the LED display on the gun.

Remote control locked due to:Error display,Local operation orRemote OptiTronic operation: LED: red and green

2. Change the powder output.Press the + or - key on the gun. The powder output will be corre-spondingly increased or decreased.

Page 26: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

20

PIN ALLOCATION

MAIN POWER SUPPLY CABLE SOCKET 2.1

Pin Function1 Neutral conductor (Power supply)2 Line (Power supply)3 System ON /OFF (Gun release) (90-264 VAC)PE Ground PE

SOCKET 2.2 - GUN 2 (EASYSELECT / OPTIGUN 1 POWDER GUN PLUG)

Pin Function1 + 15 V DC power supply Gun electronics2 Oscillator control 0-10 V DC3 GND / Trigger connection 14 Trigger connection 25 Remote control6 Ground PE

Housing Screen

SOCKET 2.3 - GUN 1 (GA02 OPTIGUN 2 / PG 1 / PG 1-A / PG 2-A POWDER GUN PLUG)

Pin Function1 GND Oscillator signal2 - - - - -3 Trigger connection 14 Trigger connection 25 Tribo electrode6 Signal Oscillator7 Ground PE

Mains connection

2.1

1

2

3PE

Page 27: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

21OptiTronic CG03

Issu

ed 0

3 / 0

3

BLOCK DIAGRAM: OPTITRONIC CONTROL UNIT

Mx -

Thro

ttle

mot

ors

*se

e V

ersi

on t

able

ELECTRICAL DIAGRAMS

Figure 2

Con

veyi

ng a

irR

insi

ng a

ir

Sup

plem

enta

ry a

irTr

igge

r va

lve

CG

02 D

ISP

LAY

SW

ITC

H P

AN

EL

CG

02 M

AIN

BO

AR

DNR

. 380

601

NR

. 379

875

NR

. 379

778

MA

INS

CO

NN

EC

TIO

NG

UN

2 *

GU

N 1

*2.

1 100-

240V

AC

M1

M2

M3

Y1

GA

01G

M01

PG

1-A

PG

2-A

PG

1

X2X5

X6

X21

X31/

X32

X11

X12

X13

X8

2.2

2.3

1.2

1.3

1.4

CG

03 P

OW

ER

AD

AP

TER

NR

. 388

297

CG

03 P

OW

ER

SU

PP

LYN

R. 3

8927

7

GA

02

Page 28: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

22

1

2

3

PE

1

2

1

2

3

4

5

6

3

4

2

1

3

6

5

4

7

8

1

2

3

2.1

GU

N 1

X2

X5

X6

CG

02 M

AIN

BO

AR

D

MA

INS

CO

NN

ECTI

ON

100-

240V

AC

gegn

bl

ws

rt

br

rt

bl

br

ws

vi

bl

NR

. 379

778

ws

ws

F12AT

4

5

PE

6

5

1

2

3

GU

N 2

4

5

2.3

2.2

2):

sieh

e Va

riant

e

Gun

11

:3

:

6:

4:

5:

GN

DTr

igge

r G

ND

Trig

ger

Trib

oG

un O

utP

E:E

rde

Gun

21

:

3:

6:

4:

5:

+15

V

GN

DTr

igge

rR

emot

e C

ontr

olEr

de

2:

Gun

Out

6

Inpu

t1

:2

:3

:4

:

N L Sys

tem

Erde

GA

01G

M01

PG

1-A

PG

2-A

PG1

F22AT

2

1

3

4

sw

sw

sw

gegn

NR

. 388

297

CG

03 P

OW

ER A

DA

PTER

2

4

3

1

sw

sw

sw

sw

X1

X2

1

3

AC

IN

1

6

PE

NR

. 389

277

CG

03 P

OW

ER S

UPP

LY

DC

OU

T

1):

Brü

cke

bei

Zwei

phas

enbe

trie

b en

tfer

nen

2)2)

1)

3893

40_0

2.sc

h

BLOCK DIAGRAM: CONNECTIONS TO MAIN BOARD (1) - OPTITRONIC CONTROL UNIT

See next page (from here)

Figure 3

Co

lou

r co

de

bl =

blu

ebr

= b

row

nge

gn =

yel

low

/gre

engn

= g

reen

rt =

red

sw =

bla

ckvi

= v

iole

tw

s =

whi

te

1) R

emov

e B

ridge

whe

n op

erat

ing

with

tw

o ph

ases

Gun

12)

PG

1-A

PG

2-A

GA

02 O

ptiG

un 2

PG

1

Gun

11:

GN

D3:

Trig

ger

GN

D4:

Trig

ger

5: T

ribo

6: G

un O

utP

E.

Gro

und

Gun

22)

GA

01 O

ptiG

un 1

GM

01

2) S

ee V

ersi

ons

Tabl

e

Inpu

t1:

N2:

L3:

Sys

tem

4: G

roun

d

Gun

21:

+15

v2:

Gun

Out

3: G

ND

4: T

rigge

r5:

Rem

ote

Con

trol

6: G

roun

d

Page 29: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

23OptiTronic CG03

Issu

ed 0

3 / 0

3

BLOCK DIAGRAM: CONNECTIONS TO MAIN BOARD (2) - OPTITRONIC CONTROL UNIT

See previous page (from here)

Figure 4

X8

FÖR

DER

LUFT

CG

02 M

AIN

BO

AR

D

1

2

3

4

5

6

Y1

bl

ws

2

1

3

4

X11

M

sw

br

or

ge

2

1

3

4

X12

M

sw

br

or

ge

2

1

3

4

X13

M

sw

br

or

ge

ZUSA

TZLU

FTSP

ÜLL

UFT

TRIG

GE

R V

EN

TIL

1.2

1.3

1.4

X21

CG

02 D

ISPL

AY

X21

NR

. 380

601

1 1

1616

1

8

1

20

X31

X32

SWIT

CH

PA

NEL

NR

. 379

875

Co

lou

r co

de

bl =

blu

ebr

= b

row

nge

= y

ello

wor

= o

rang

esw

= b

lack

ws

= w

hite

Trig

ger

Val

veC

onve

ying

air

Sup

plem

enta

ry a

irR

insi

ng a

ir

Page 30: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

24

PNEUMATIC DIAGRAM

DR

= P

ress

ure

redu

cing

val

ve (1

2 gu

n)

EL

= E

lect

rode

rin

sing

FL =

Con

veyi

ng a

ir

M1

= T

hrot

tle m

otor

sS

V =

Sol

enoi

d va

lve

- 24

V D

C

ZL =

Sup

plem

enta

ry a

ir

Inpu

t pre

ssur

e

Figure 5

MV

(Y

1)

ZL(1

.3)

FL(1

.2)

EL

(1.4

)

DR

5.5-

8.0

bar

5.0

bar

(1.1

IN

)

OPTITRONIC CONTROL UNIT

Page 31: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

25OptiTronic CG03

Issu

ed 0

3 / 0

3

ORDERING SPARE PARTS

When ordering Spare parts for powder coating equipment, pleaseindicate the following specifications:

1. Type and serial number of your powder coating equipment2. Order number, quantity, and description of each spare part

Example:

1. Type OptiTronic, Serial No.: XXX XXX2. Order No.: 221 873, 5 pieces, 2 AT fuse

When ordering cable and hose material the length required must begiven.

The spare part numbers of yard/meter ware always begins with 1.. ...

and are always marked with an * in the spare parts list.

Wear parts are always marked with a #.

All dimensions for plastic powder hoses are given as external diameter(o/d) and internal diameter (i/d):

e. g.ø 8 / 6 mm, 8 mm outside diameter / 6 mm inside diameter (i/d).

SPARE PARTS LIST

Page 32: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

26

OPTITRONIC CONTROL UNIT

Version 1 - GA or GM Gun 384 640Version 2 - PG Guns 386 162

ABBREVIATIONS:

PG GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A = G1 = Gun 1GA / GM GA01 OptiGun 1 / GM 01 EasySelect = G2 = Gun 2

Example: CG 03 OptiTronic Powder Gun Control unit, Version 2Rear plate with connections(see also "OptiTronic Version Table", and "Conversion Table")

Figure 6

Page 33: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

27OptiTronic CG03

Issu

ed 0

3 / 0

3

OPTITRONIC CONTROL UNIT - COMPLETE

2 CG Front plate - complete 379 7944 EPROM 27C512-70 - Software version 2.XX* 387 037

Figure 7

4

2

Page 34: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

28

PNEUMATICS

1 Throttle motor - FL or ZL - complete 380 5552 Throttle motor - EL - complete 380 5633 Main solenoid valve - 24 V DC - complete 262 4554 Power adapter 388 297

Fuse - 2 AT 221 872

12

Figure 8

3

4

Page 35: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

29OptiTronic CG03

Issu

ed 0

3 / 0

3

1

1 CG 03 Power supply 389 277Fuse - 4 AF - 250 V 262 897

POWER SUPPLY

Figure 9

Page 36: OptiTronic Powder Gun Control (CG03) · 2012. 4. 6. · Gun 1 - 2.3 socket (GA02 OptiGun 2 / PG 1 / PG 1-A / PG 2-A Powder Guns - Alternatively) The gun cable plug is connected to

OptiTronic CG03

Issu

ed 0

3 / 0

3

30

DOCUMENTATION OPTITRONIC

© Copyright 2000 ITW Gema AG., CH-9015 St. GallenAll rights reserved.

This publication is protected by copyright. Unauthorized copying isprohibited by law. No part of this publication may be reproduced,photocopied, translated, stored on a retrieval system or transmitted inany form or by any means, for any purpose, neither as a whole norpartially, without the express written consent of ITW Gema AG.

OptiTronic, OptiGun, EasyTronic, EasySelect, EasyFlow and SuperCoro-na are registered trademarks of ITW Gema AG.OptiMatic, OptiMove, OptiMaster, OptiPlus, OptiMulti and Gematic aretrademarks of ITW Gema AG.

All other product names are trademarks or registered trademarks oftheir respective holders.

Reference is made in this manual to different trademarks or registeredtrademarks. Such references do not mean that the manufacturersconcerned approve of or are bound in any form by this manual. Wehave endeavoured to retain the preferred spelling of the trademarks,and registered trademarks of the copyright holders.

To the best of our knowledge and belief, the information contained inthis publication was correct and valid on the date of issue. ITW GemaAG makes no representations or warranties with respect to the con-tents or use of this publication, and reserves the right to revise thispublication and make changes to its content without prior notice.

PRINTED IN SWITZERLAND

ITW Gema AGMövenstrasse 179015 St. GallSwitzerland

Phone: +41-71-313 83 00Fax: +41-71-313 83 83

E-mail: [email protected] page: www.itwgema.ch