22
Open DWDM systems deployment Lada Altmannová CESNET www.ces.ne t Praha, May 14th, 2009

Open DWDM systems deployment Lada Altmannová CESNET Praha, May 14th, 2009

Embed Size (px)

Citation preview

Page 1: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

Open DWDM systems deployment

Lada AltmannováCESNET

www.ces.net

Praha, May 14th, 2009

Page 2: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

2CEF Networks Workshop 2009

Author participates on Optical networks activity of CESNET research program,

GN3 and Phosphorus project

Presented ideas do not necessarily reflect an official opinion of the GN3, CESNET or any other institution or project.

Page 3: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

3CEF Networks Workshop 2009

CESNET

CESNET2 network Dark fibre experimental facility (EF)

5 112 km leased fibres (high coverage on 78 864 km2 )– Including 995 km of single fibre lines

– Including Experimental facility 535 km of dark fibre

Page 4: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

4CEF Networks Workshop 2009

Motivation for lit fibre service

Full fibre capacity can be dedicated for NREN! (no return to traditional telco services)

NREN can share leased dark fibre with other organizations (legal bodies) Lighting is outsourced (Some NRENs has no staff experienced in optics

and electronics) Buying of service instead of investment into equipment (OPEX instead of

CAPEX) Costs of adding lambdas (or other extensions) should be part of contract Provider will obtain experience with new type of service and can offer

this new type of service to other customers Deployment of new photonics devices – technology transfer to telco

providers

Page 5: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

5CEF Networks Workshop 2009

Used procedure – what we learned

Detailed description of procuring of lit fibres is on http://www.ces.net/events/cef2007/p/altmannova.ppt

Project of lighting can be prepared by NREN staff or by independent company Contract with one provider per whole line Detailed description of acceptance agreement (part of handover report)

- Description of the line (address, contact persons, length, attenuation…)- Channel plan- Block diagram of the line (equipment, points of power measurement)- Tables and charts of measurement- Setting of equipment- Result and conclusion

Page 6: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

6CEF Networks Workshop 2009

Ways of lit fibres service acquiring

Upgrade of leased dark fibre lines (the most applied solution) – extensive experience

Tender for lit fibre HW order and deployment by own staff (verification of

new methods)

Page 7: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

7CEF Networks Workshop 2009

Previous situation in 2007

Page 8: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

8CEF Networks Workshop 2009

Steps of history

First CL (CzechLight) deployment in the year 2004, specifically CLA PB01 (CzechLight Amplifier 2in1, Booster and Preamplifier) was on Praha – Plzeň line with length of 159km in CzechLight EF and on Praha – Hradec Králové, length of 150km in CESNET2 network.

Since March 2005 CLA DI01 (CzechLight Amplifier DualInline)has been successfully working on CzechLight EF line Praha-Brno, 284km, as one and only inline amplifier.

At the beginning of 2006 CLA PB01 was equipped on the first Cross Border Fibre (CBF) line Brno – Bratislava, 182km. In the middle of 2006 CBF Brno – Vienna, 224km was deployed by a new prototype CLA PB02.

Page 9: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

9CEF Networks Workshop 2009

New optical transmission DWDM systems, based on own open photonic devices called the CzechLight (CL) family

Main types without gain flattening for up to 8 channels: CLA PB01 Low noise preamplifier and booster amplifier with output power

up to 20dBm and optional ALS (Automatic Laser Shutdown) CLA PB02 Low noise preamplifier and high-power booster amplifier with

output power up to 27dBm and built-in ALS CLA DI01 Dual in-line amplifier with output powers up to 15dBmMain types with gain flattening for up to 32 channels: CLA PB01F Gain flattened low noise preamplifier and booster amplifier with

output power up to 20dBm and optional ALS CLA PB02F Gain flattened low noise preamplifier and high-power booster

amplifier with output power up to 27dBm and built-in ALS CLA DI01F Gain flattened dual in-line amplifier with output powers up to 15

dBm

Page 10: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

10CEF Networks Workshop 2009

CLA deployment up to 2007

CESNET2 Type of CLA Number of CLA Length (km) Since year

Brno - Bratislava PB01 2 182 2006

Brno - Vídeň PB02 2 224 2006

Praha - Ústí n. L. PB01 2 131 2007

Ústí n. L. - Liberec PB01 2 123 2007

CzechLight EF Type of CLA Number of CLA Length (km) Since year

Praha - Potěhy - Brno DI01F, 2x PB02Fx 3 284 2005

Brno - Štetovice - Cieszyn DI01F, 2x PB02Fx 3 263 2007

Total deployed (December 2007)   14

1 207

CLA DI01 (originally CzechLight Amplifier DualInline)

CLA PB01 (originally CzechLight Amplifier 2in1, Booster and Preamplifier)

Page 11: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

11CEF Networks Workshop 2009

CLA deployment 2008 - 2009CESNET2 Type of CLA Number of CLA Length (km) Since year

Brno - Ostrava PB02F 2 235 2008

ČB - Jihlava PB01F 2 164 2008

Jihlava - Brno PB01F 2 156 2008

Cheb - Most PB01F 2 171 2008

Letohrad - Opava PB01F 2 186 2008

Most - Děčín - Ústí n.L. PB01F 2 135 2008

Most - Ústí n.L PB01F 3 68 2008

Plzeň - Cheb PB01F 2 137 2008

Praha - Pardubice PB02F 2 189 2008

Brno - Zlín PB02F 2 129 2009

Hradec Králové - Pardubice DI02F 1 30 2009

CzechLight EF Type of CLA Number of CLA Length (km) Since year

Praha - Jihlava PB02F 2 191 2009

Total deployed (January 2008 - May 2009) 24 1 790

Page 12: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

12CEF Networks Workshop 2009

CLA deployment up to May 2009

CESNET2 Number of CLA Length (km) Since year

4 406 2006

4 254 2007

19 1440 2008

3 159 2009

CzechLight EF Number of CLA Length (km) Since year

3 284 2005

3 263 2007

2   191 2009

Total deployment up to May 2009 38 2 997

Page 13: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

13CEF Networks Workshop 2009

DWDM operational in 2009 and plans

Page 14: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

14CEF Networks Workshop 2009

Open DWDM system 10G with using of CzechLight Amplifiers on CBF

CESNET2 Type of

CLANumber of

CLALength

(km)

Brno - Bratislava PB01 2 182

Ostrava – B. Biala (prepared change) PB01F 2 105

Brno - Vienna PB02 2 224

Page 15: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

15CEF Networks Workshop 2009

CBF triangle for reliability

Page 16: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

16CEF Networks Workshop 2009

CBF one year statisticsBit rates  [bps]

Input bitrate

min=0.000  

max=2.552G  

avr=792.124M  

Output bitrate

min=0.000  

max=3.456G  

avr=1.281G  

One year load of Brno - Vienna author: Tom Kosnar, copyright: © 2004-2009 , CESNET a.l.e

Bit rates  [bps]

Input bitrate

min=12.421M  

max=1.663G  

avr=274.505M  

Output bitrate

min=7.633M  

max=3.656G  

avr=309.706M  One year load of Brno - Bratislava author: Tom Kosnar, copyright: © 2004-2009 , CESNET a.l.e

Page 17: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

17CEF Networks Workshop 2009

Pilot deployment

Project FTTH in Slovak Republic (Bánovce nad Bebravou)

Link: http://internetprovsechny.cz/download/OptoNet-FTTx.ppt

Page 18: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

18CEF Networks Workshop 2009

Open DWDM deployment plans 2009

CESNET2 Type of CLA Number of CLA Length (km)

Olomouc - Zlín PB01F 2 72

Ostrava - Opava DI02F 1 44

Ostrava - Karviná PB01F 2 69

Brno - Kyjov PB01F 2 92

Total 7 277

Total deployment up to December 2009 45 3 274

Note : Blue - single fibre lines

Page 19: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

19CEF Networks Workshop 2009

Links

Detailed information about open photonics DWDM systems are availabe in CESNET Technical report on http://www.cesnet.cz/doc/techzpravy

Josef Vojtěch, Václav Novák, Miloslav Hůla :Open photonics DWDM systems deployment within the CESNET2 network, with emphasis to single fibre bidirectional operation

Current traffic statistics of above mentioned lines with CL equipment: http://www.cesnet.cz/provoz/zatizeni

Page 20: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

20CEF Networks Workshop 2009

RESULTS Enough time for project preparing and negotiation is

necessary

After implementation and testing, 15 upgraded lines of CESNET2 are running with very high reliability

Projects are successful and can be repeated

Page 21: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

21CEF Networks Workshop 2009

Acknowledgement

CESNET colleagues, especially Jan Gruntorád, Miloslav Hůla, Tomáš Košňar, Václav Novák, Jan Radil, Stanislav Šíma, Josef Vojtěch

Neighbour colleagues Marian Ďurkovič, Marcin Garstka, Christian Panigl,

Page 22: Open DWDM systems deployment Lada Altmannová CESNET  Praha, May 14th, 2009

Thank you for your attention