OFFSHORE CABLESNEK 606
GrGroupoup
Offshore CablesNEK 606
Dual CompoundHalogen Free - Mud Resistant
(–40 Deg C)
Low SmokeFlame Retardant
Fire Resistant
Type Approvals:
• ABS American Bureau of Shipping• DNV Det Norske Veritas• LRS Lloyd’s Register of Shipping
Type Approvals
ABS DNV
Lloyd’s Register
3
DUAL COMPOUNDNEK 606 Offshore Cables
The objective of CONTROLCAVI INDUSTRIA was to develop a cable whichwill perform some of the most inhospitable conditions imaginableSaline atmosphere, UV radiation, extremes of temperature, hydrocarbons,oils, drilling fluids and muds while still maintaining the highest levels ofsafety for personnel requiring.High levels of flame retardance with zero emissions of halogens and toxicgases, which can endanger life and the safety of installation.
By developing a sheathing compound which meets the demands of allthese criteria with outstanding fire performance and high level of resistanceto atmospheric and chemical attack, CONTROLCAVI INDUSTRIA can offerowners and operators the perfect solution for the transmission of allelectrical energy, from mV signals to Medium tensions.
The result of this development is a cable with properties far in excess of therequirements stipulated in NEK 606 and associates IEC specifications. Inaddition, the conductors, insulating and sheathing compounds have thefollowing unique properties:
DUAL COMPOUND sheathing which is both halogen free andresistant to drilling fluids, muds and associates environmental conditions.
EASE OF INSTALLATION always an important consideration,for medium to large cross sectional cables, from the conceptual designthrough to the final installation with the unique conductor configuration ofmulti stranded class 2 tinned conductors which have the electricalresistance of “traditional” minimal strand conductors.CONTROLCAVI INDUSTRIA have developed a unique solution whichreduces total installation costs by offering a significant reduction inbending radius and speed of installation.
4
COLD BEND AND IMPACT (CSA C22.2) –40 Deg Cwith the search of hydrocarbons in ever more inhospitable climates andincreased use of FPSO vessels which can find themselves operating inextremes of temperature from one field to another, all cables manufacturedby CONTROLCAVI INDUSTRIA can be installed and operate attemperatures down to –40 Deg Centigrade.(test witnessed by ABS, DNV and LRS)
HEPR INSULATION in order to increase the insulating properties,and, as a result the current carrying capacity of 0,6/1 kV cables andabove, CONTROLCAVI INDUSTRIA have developed High ModulusEthylene Propylene Rubber (HEPR) compound.This offers superior insulation constant (Ki) and significantly improvedageing performance at higher operating temperatures than the traditional85 Deg C EPR compounds. These results can be seen below on the ARRHENIUSGRAPH obtained by performing the Thermal Endurance Evaluation accordingto IEC 60216, where Temperature Index achieved has been Ti = 114 Deg C(witnessed by ABS, DNV and LRS)
2,66 2,61 2,56 2,51 2,46 2,41 2,36 2,31 2,26 2,21 2,16 2,11100.000
10.000
20.000
1.000
100
100 110 114 120 130 140 150 160 170 180 190 20010
Reciprocal thermodynamic temperature (1000/Deg K)
Tim
e (h
ours
)
Temperature (Deg C)
5
Reference Standards The informations in this catalog apply to materials, constructions, andtesting of power and telecommunication shipboard and offshore cablesaccording to next standards:
IEC 60092-350 Low voltage shipboard power cables.General construction and test requirements.
IEC 60092-351 Insulating materials of shipboard power cables.
IEC 60092-353 Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1 kV and 3 kV.
IEC 60092.354 Single and three-core power cables with extruded solid insulation for rated voltages 6 kV, 10 kV and 15 kV
IEC 60092-359 Sheathing materials for shipboard power and telecommunication cables.
IEC 60092-375 Shipboard telecommunication cables and radio-frequency cables. General instrumentation, control and telecommunicationcables.
IEC 60331 Fire-resistant characteristics of electric cables
IEC 60332-1 Tests on electric cables under fire conditions.Test on a single vertical insulated wire or cable.
IEC 60332-3 Tests on electric cables under fire conditions.Tests on bunched wires or cables
IEC 60754-1/2 Test on gases evolved during combustion of electric cables.Part 1: Determination of the haogen acid gasPart 2: Determination of the degree of acidity duringthe combustion of materials taken from electric cablesby measuring pH and conductivity.
IEC 61034-1/2 Measurement of smoke density of cables burning under defined conditions.
NEK 606 Cables for offshore installation halogen-free or mud resitant
NVE 1990 FEA-M regulation Regulation for electrical installations - maritime installationsClause 1238 Methodes of earthing and dimensions
CSA C22.2 N° 38-95Thermoset Insulated Wires and Cables - Wiring ProductsClause 6.4.4 Low Temperature Flexibility (- 40 Deg C)Clause 6.4.5 Low Temperature Impact (- 40 Deg C)
6
Cable designationin accordance to NEK 606
R ethylene propylene (HEPR or EPR) insulation halogen free flame retardant
B mica tape + HEPR or EPR insulationfire resistant halogen free flame retardant
F SHF2 thermosetting bedding compoundhalogen free flame retardant
O tinned copper wire braid armour
U SHF2 thermosetting dual compoundHALOGEN FREE & MUD RESISTANT flame retardant - low temperature - 40 Deg C
(C) common screen of copper / polyester tapetinned copper drain wire over assembled pairs / triples
( I ) individual screen of copper / polyester tapetinned copper drain wire over each pair / triple
P1/P8 power & control 0,6 / 1 kVHALOGEN FREE & MUD RESISTANT flame retardant
P2/P9 power medium voltage 3,6 / 6 kVHALOGEN FREE & MUD RESISTANT flame retardant
P3/P10 power medium voltage 6 / 10 kVHALOGEN FREE & MUD RESISTANT flame retardant
P4/P11 power medium voltage 8,7 / 15 kVHALOGEN FREE & MUD RESISTANT flame retardant
P5/P12 power & control 0,6 / 1 kVHALOGEN FREE & MUD RESISTANT flame retardant fire resistant
S1/S5 instrumentation individual screen 250 VHALOGEN FREE & MUD RESISTANT flame retardant
S2/S6 instrumentation common screen 250 VHALOGEN FREE & MUD RESISTANT flame retardant fire resistant
S3/S7 instrumentation individual screen 250 VHALOGEN FREE & MUD RESISTANT flame retardant fire resistant
S4/S8 instrumentation common screen 250 VHALOGEN FREE & MUD RESISTANT flame retardant fire resistant
8
NEK 606
Halogen freeMUD resistant
–40 Deg C
Flame retardant
PPPOOOWWWEEERRR &&& CCCOOONNNTTTRRROOOLLL UUUNNNAAARRRMMMOOOUUURRREEEDDD
RRRUUU 000,,,666///111 kkkVVV HHHAAALLLOOOGGGEEENNN FFFRRREEEEEE &&& MMMUUUDDD RRREEESSSIIISSSTTTAAANNNTTT
Design and construction IEC 60092-353 IEC 60092-3 Operating temperature 85 Deg C Nominal voltage Uo / U 0.6 / 1 kV Flame retardancy IEC 60332-1 IEC 60332-3 cat A Corrosivity IEC 60754 -1 IEC 60754-2 Smoke density IEC 61034-2 MUD resistance NEK 606
CONSTRUCTION DATA
1. CONDUCTOR tinned copper IEC 60228 class 2 2. INSULATION halogen free HEPR compound 3. SEPARATOR halogen free tape
4. OUTER SHEATH SHF2 thermoset dual compound halogen free & MUD resistant
CORES IDENTIFICATION
1 core off-white (grey) 2 cores off-white - black 3 cores off-white - black - red 4 cores off-white - black - red - blue
5 cores and above white & numbered
sheath colour black
SHEATH MARKING CCI RU 0.6/1 kV n x s / braid mm2 NEK 606 IEC 60332-3A QA ref metric marking
RU 0,6/1 kV Nominal dimensional and electrical data 0,6/1 KV
CONSTRUCTION INSULATION OVERAL WEIGHT CONDUCTOR CURRENT SHORT
THICKNESS DIAMETER (APPROX) RESISTANCE RATING CIRCUIT
(APPROX) AT 20 Deg C AT 45 Deg C RATING
(mm) (mm) (mm) (kg/km) Ohm/km (A) (KA)
1x16 1,0 10,0 225 1,160 90 2,331x25 1,2 12,0 330 0,735 120 3,651x35 1,2 13,0 435 0,530 145 5,111x50 1,4 15,5 580 0,391 180 7,301x70 1,4 17,0 820 0,270 225 10,201x95 1,6 19,0 1075 0,195 275 13,901x120 1,6 21,5 1345 0,154 320 17,501x150 1,8 23,5 1670 0,126 365 21,901x185 2,0 25,5 2050 0,100 415 27,001x240 2,2 29,0 2655 0,076 490 35,001x300 2,4 32,0 3390 0,061 560 43,80
2x1,5 1,0 10,0 140 12,200 17 0,212x2,5 1,0 10,5 175 7,560 24 0,352x4 1,0 12,5 225 4,700 32 0,582x6 1,0 13,0 295 3,110 41 0,87
3x1,5 1,0 10,5 160 12,200 14 0,213x2,5 1,0 12,0 195 7,560 20 0,363x4 1,0 12,5 275 4,700 27 0,583x6 1,0 14,0 340 3,110 34 0,873x10 1,0 16,0 510 1,840 47 1,463x16 1,0 19,0 750 1,160 63 2,333x25 1,2 22,5 1105 0,735 84 3,653x35 1,2 25,5 1460 0,530 102 5,113x50 1,4 29,0 2040 0,391 126 7,303x70 1,4 34,0 2850 0,270 158 10,203x95 1,6 38,5 3675 0,195 193 13,903x120 1,6 42,0 4600 0,154 224 17,503x150 1,8 47,0 5750 0,126 256 21,90
4x1,5 1,0 12,0 190 12,200 14 0,214x2,5 1,0 12,5 245 7,560 20 0,364x4 1,0 14,0 330 4,700 27 0,584x6 1,0 15,5 445 3,110 34 0,874x10 1,0 18,5 640 1,840 47 1,464x16 1,0 20,5 950 1,160 63 2,334x25 1,2 25,5 1455 0,735 84 3,654x35 1,2 28,5 1915 0,530 102 5,114x50 1,4 33,0 2630 0,391 126 7,30
7x1,5 1,0 14,5 295 12,200 11 0,2112x1,5 1,0 18,0 475 12,200 9 0,2119x1,5 1,0 21,5 715 12,200 8 0,21
7x2,5 1,0 15,5 380 7,560 15 0,3612x2,5 1,0 21,0 580 7,560 12 0,3619x2,5 1,0 24,0 875 7,560 11 0,36
IIINNNSSSTTTRRRUUUMMMEEENNNTTTAAATTTIIIOOONNN UUUNNNAAARRRMMMOOOUUURRREEEDDD
RU(c) 250 V HHHAAALLLOOOGGGEEENNN FFFRRREEEEEE &&& MMMUUUDDD RRREEESSSIIISSSTTTAAANNNTTT --- CCCOOOMMMMMMOOONNN SSSCCCRRREEEEEENNN
Design and construction IEC 60092-375 IEC 60092.353
IEC 60092.3 Nominal voltage 250 V Operating temperature 85 Deg C Flame retardancy IEC 60332-1 IEC 60332-3 cat A Corrosivity IEC 60754-1 IEC 60754-2 Smoke density IEC 61034-2 MUD resistance NEK 606
CONSTRUCTION DATA
1. CONDUCTOR tinned stranded copper wire IEC 60228 class 2
2. INSULATION halogen free HEPR compound
3. COMMON SCREEN copper/polyester tape tinned copper drain wire
4. OUTER SHEATH SHF2 thermoset compound halogen free & MUD resistant
PAIR / TRIPLE IDENTIFICATION
pair black light blue triple light blue black brown
pairs / triples progressively numbered
sheath colour grey
blue for intrinsically safe
SHEATH MARKING CCI RU (c) 250 V n x p(trp) x s NEK 606 IEC 60332-3A QA ref metric marking
RU (c) 250 Volt Nominal dimensional and electrical data 250 Volt
CONSTRUCTION INSULATION OVERALL WEIGHT CONDUCTOR
THICKNESS DIAMETER (APPROX) RESISTANCE
(APPROX) AT 20 Deg C
(mm) (mm) (mm) (kg/km) Ohm/km
2 pair 0,75 0,8 11,5 170 26,6004 pair 0,75 0,8 13,5 235 26,6008 pair 0,75 0,8 18,0 430 26,60012 pair 0,75 0,8 21,0 615 26,60016 pair 0,75 0,8 23,0 740 26,60024 pair 0,75 0,8 28,5 1075 26,600
2 pair 1,5 0,8 13,5 245 12,2004 pair 1,5 0,8 16,0 350 12,2008 pair 1,5 0,8 21,5 650 12,20012 pair 1,5 0,8 25,0 900 12,20016 pair 1,5 0,8 27,0 1125 12,20024 pair 1,5 0,8 32,5 1675 12,200
2 triple 0,75 0,8 13,0 210 26,6004 triple 0,75 0,8 15,0 325 26,6008 triple 0,75 0,8 20,5 580 26,60012 triple 0,75 0,8 24,5 825 26,60016 triple 0,75 0,8 26,0 1025 26,60024 triple 0,75 0,8 31,5 1500 26,600
2 triple 1,5 0,8 14,5 320 12,2004 triple 1,5 0,8 18,0 475 12,2008 triple 1,5 0,8 23,5 870 12,20012 triple 1,5 0,8 28,0 1275 12,20016 triple 1,5 0,8 29,5 1580 12,20024 triple 1,5 0,8 37,0 2340 12,200
IIINNNSSSTTTRRRUUUMMMEEENNNTTTAAATTTIIIOOONNN UUUNNNAAARRRMMMOOOUUURRREEEDDD
RU(i) 250 V HHHAAALLLOOOGGGEEENNN FFFRRREEEEEE &&& MMMUUUDDD RRREEESSSIIISSSTTTAAANNNTTT --- IIINNNDDDIIIVVVIIIDDDUUUAAALLL SSSCCCRRREEEEEENNN
Design and construction IEC 60092.375 IEC 60092.353
IEC 60092.3 Nominal voltage 250 V Operating temperature 85 Deg C Flame retardancy IEC 60332-1 IEC 60332-3 cat A Corrosivity IEC 60754-1 IEC 60754-2 Smoke density IEC 61034-2 MUD resistance NEK 606
CONSTRUCTION DATA
1. CONDUCTOR tinned stranded copper wire IEC 60228 class 2
2. INSULATION halogen free HEPR compound
3. INDIVIDUAL SCREEN Copper / Polyester tape tinned copper drain wire
4. OUTER SHEATH SHF2 thermoset compound halogen free & MUD resistant
PAIR / TRIPLE IDENTIFICATION
pair black light blue triple light blue black brown
pairs / triples progressively numbered
sheath colour grey blue for intrinsically safe
SHEATH MARKING CCI RU (i) 250 V n x p(trp) x s mm2 NEK 606 IEC 60332-3A QA ref metric marking
RU (i) 250 Volt Nominal dimensional and electrical data 250 Volt
CONSTRUCTION INSULATION OVERALL WEIGHT CONDUCTOR
THICKNESS DIAMETER (APPROX) RESISTANCE
(APPROX) AT 20 Deg C
(mm) (mm) (mm) (kg/km) Ohm/km
1 pair 0,75 0,8 8,0 95 26,6002 pair 0,75 0,8 12,0 185 26,6004 pair 0,75 0,8 13,0 275 26,6008 pair 0,75 0,8 18,5 530 26,60012 pair 0,75 0,8 21,5 750 26,60016 pair 0,75 0,8 24,5 940 26,60024 pair 0,75 0,8 30,0 1415 26,600
1 pair 1,5 0,8 9,0 135 12,2002 pair 1,5 0,8 13,5 260 12,2004 pair 1,5 0,8 15,5 420 12,2008 pair 1,5 0,8 21,5 775 12,20012 pair 1,5 0,8 25,5 1125 12,20016 pair 1,5 0,8 29,0 1435 12,20024 pair 1,5 0,8 35,0 2140 12,200
1 triple 0,75 0,8 8,5 110 26,6002 triple 0,75 0,8 13,0 230 26,6004 triple 0,75 0,8 15,0 355 26,6008 triple 0,75 0,8 20,5 675 26,60012 triple 0,75 0,8 24,5 975 26,60016 triple 0,75 0,8 28,0 1240 26,60024 triple 0,75 0,8 34,0 1825 26,600
1 triple 1,5 0,8 9,5 165 12,2002 triple 1,5 0,8 14,5 345 12,2004 triple 1,5 0,8 18,0 540 12,2008 triple 1,5 0,8 24,5 995 12,20012 triple 1,5 0,8 29,5 1500 12,20016 triple 1,5 0,8 32,0 1905 12,20024 triple 1,5 0,8 41,0 2875 12,200
IEC 60332.3 Cat. A FLAME RETARDANT TEST
10
NEK 606
Halogen freeMUD resistant
–40 Deg C
Fire resistant
PPPOOOWWWEEERRR &&& CCCOOONNNTTTRRROOOLLL UUUNNNAAARRRMMMOOOUUURRREEEDDD
BBBUUU 000,,,666///111 kkkVVV HHHAAALLLOOOGGGEEENNN FFFRRREEEEEE &&& MMMUUUDDD RRREEESSSIIISSSTTTAAANNNTTT
FFFIIIRRREEE RRREEESSSIIISSSTTTAAANNNTTT
Design and construction IEC 60092-353 IEC 60092-3 Operating temperature 85°C Nominal voltage Uo / U 0.6 / 1 kV Flame retardancy IEC 60332-1 IEC 60332-3 cat A Fire resistance IEC 60331-21 Corrosivity IEC 60754 -1 IEC 60754-2 Smoke density IEC 61034-2 MUD resistance NEK 606
CONSTRUCTION DATA
1. CONDUCTOR tinned copper IEC 60228 class 2
2. INSULATION mica tape + halogen free HEPR compound
3. SEPARATOR halogen free tape
4. OUTER SHEATH SHF2 thermoset dual compound halogen free & MUD resistant
CORES IDENTIFICATION
1 core off-white (grey) 2 cores off-white - black 3 cores off-white - black - red 4 cores off-white - black - red - blue
5 cores and above white & numbered
sheath colour black
SHEATH MARKING CCI BU 0.6/1 kV n x s / braid mm2 NEK 606 IEC 60331-21 QA ref metric marking
BU 0,6/1 kV Nominal dimensional and electrical data 0,6/1 KV
CONSTRUCTION INSULATION OVERALL WEIGHT CONDUCTOR CURRENT SHORT
THICKNESS DIAMETER (APPROX) RESISTANCE RATING CIRCUIT
(APPROX) AT 20 Deg C AT 45 Deg C RATING
(mm) (mm) (mm) (kg/km) Ohm/km (A) (KA)
1x16 1,0 10,0 240 1,160 90 2,331x25 1,2 12,0 355 0,735 120 3,651x35 1,2 13,5 460 0,530 145 5,111x50 1,4 15,5 615 0,391 180 7,301x70 1,4 17,0 820 0,270 225 10,201x95 1,6 19,5 1110 0,195 275 13,90
1x120 1,6 21,5 1375 0,154 320 17,501x150 1,8 24,0 1680 0,126 365 21,901x185 2,0 26,5 2070 0,100 415 27,001x240 2,2 29,0 2700 0,076 490 35,001x300 2,4 32,0 3335 0,061 560 43,80
2x1,5 1,0 10,5 150 12,200 17 0,212x2,5 1,0 11,5 190 7,560 24 0,352x4 1,0 12,5 245 4,700 32 0,582x6 1,0 13,5 305 3,110 41 0,87
3x1,5 1,0 11,5 175 12,200 14 0,213x2,5 1,0 12,0 220 7,560 20 0,363x4 1,0 13,5 305 4,700 27 0,583x6 1,0 15,0 380 3,110 34 0,873x10 1,0 17,0 550 1,840 47 1,463x16 1,0 19,0 775 1,160 63 2,333x25 1,2 23,0 1170 0,735 84 3,653x35 1,2 26,5 1555 0,530 102 5,113x50 1,4 31,0 2125 0,391 126 7,30
4x1,5 1,0 12,5 230 12,200 14 0,214x2,5 1,0 13,5 295 7,560 20 0,364x4 1,0 15,5 375 4,700 27 0,584x6 1,0 16,5 485 3,110 34 0,874x10 1,0 19,5 690 1,840 47 1,464x16 1,0 21,0 1010 1,160 63 2,334x25 1,2 26,0 1515 0,735 84 3,654x35 1,2 29,0 1965 0,530 102 5,114x50 1,4 33,0 2680 0,391 126 7,30
7x1,5 1,0 14,5 330 12,200 11 0,2112x1,5 1,0 19,5 510 12,200 9 0,2119x1,5 1,0 23,0 775 12,200 8 0,21
7x2,5 1,0 16,0 405 7,560 15 0,3612x2,5 1,0 21,0 645 7,560 12 0,3619x2,5 1,0 25,0 980 7,560 11 0,36
IIINNNSSSTTTRRRUUUMMMEEENNNTTTAAATTTIIIOOONNN UUUNNNAAARRRMMMOOOUUURRREEEDDD
BU(c) 250 V HHHAAALLLOOOGGGEEENNN FFFRRREEEEEE &&& MMMUUUDDD RRREEESSSIIISSSTTTAAANNNTTT CCCOOOMMMMMMOOONNN SSSCCCRRREEEEEENNN
FFFIIIRRREEE RRREEESSSIIISSSTTTAAANNNTTT
Design and construction IEC 60092-375 IEC 60092.353
IEC 60092.3 Nominal voltage 250 V Maximum rated temperature 85 Deg C Flame retardancy IEC 60332-1 IEC 60332-3 cat A Fire resistance IEC 60331 Corrosivity IEC 60754-1 IEC 60754-2 Smoke density IEC 61034-2 MUD resistance NEK 606
CONSTRUCTION DATA
1. CONDUCTOR tinned stranded copper wire IEC 60228 class 2
2. INSULATION mica tape + halogen free HEPR compound
3. COMMON SCREEN copper/Polyester tape tinned copper drain wire
4. OUTER SHEATH SHF2 thermoset compound halogen free & MUD resistant)
PAIR / TRIPLE IDENTIFICATION
pair black light blue triple light blue black brown
pairs / triples progressively numbered
sheath colour grey
blue for intrinsically safe SHEATH MARKING
CCI BU (c) 250 V n x p(trp) x s mm2 NEK 606 IEC 60331-21 QA ref metric marking
BU (c) 250 Volt Nominal dimensional and electrical data 250 Volt
CONSTRUCTION INSULATION OVERALL WEIGHT CONDUCTOR
THICKNESS DIAMETER (APPROX) RESISTANCE
(APPROX) AT 20 Deg C
(mm) (mm) (mm) (kg/km) Ohm/km
2 pair 0,75 0,8 12,5 190 26,6004 pair 0,75 0,8 14,0 265 26,6008 pair 0,75 0,8 20,0 490 26,60012 pair 0,75 0,8 22,5 685 26,60016 pair 0,75 0,8 24,5 840 26,60024 pair 0,75 0,8 31,0 1240 26,600
2 pair 1,5 0,8 14,0 255 12,2004 pair 1,5 0,8 16,0 375 12,2008 pair 1,5 0,8 22,5 710 12,20012 pair 1,5 0,8 26,0 975 12,20016 pair 1,5 0,8 28,0 1225 12,20024 pair 1,5 0,8 34,5 1815 12,200
2 triple 0,75 0,8 14,0 240 26,6004 triple 0,75 0,8 16,5 355 26,6008 triple 0,75 0,8 21,5 650 26,60012 triple 0,75 0,8 26,0 950 26,60016 triple 0,75 0,8 28,0 1155 26,60024 triple 0,75 0,8 34,5 1725 26,600
2 triple 1,5 0,8 16,0 345 12,2004 triple 1,5 0,8 18,5 520 12,2008 triple 1,5 0,8 25,5 950 12,20012 triple 1,5 0,8 30,5 1375 12,20016 triple 1,5 0,8 33,0 1740 12,20024 triple 1,5 0,8 40,0 2575 12,200
IIINNNSSSTTTRRRUUUMMMEEENNNTTTAAATTTIIIOOONNN UUUNNNAAARRRMMMOOOUUURRREEEDDD
BU(i) 250 V HHHAAALLLOOOGGGEEENNN FFFRRREEEEEE &&& MMMUUUDDD RRREEESSSIIISSSTTTAAANNNTTT IIINNNDDDIIIVVVIIIDDDUUUAAALLL SSSCCCRRREEEEEENNN
FFFIIIRRREEE RRREEESSSIIISSSTTTAAANNNTTT
Design and construction IEC 60092-375 IEC 60092.353
IEC 60092.3 Nominal voltage 250 V Maximum rated temperature 85 Deg C Flame retardancy IEC 60332-1 IEC 60332-3 cat A Fire resistance IEC 60331-21 Corrosivity IEC 60754-1 IEC 60754-2 Smoke density IEC 61034-2 MUD resistance NEK 606
CONSTRUCTION DATA
1. CONDUCTOR tinned stranded copper wire IEC 60228 class 2
2. INSULATION mica tape + halogen free HEPR compound
3. INDIVIDUAL SCREEN copper/Polyester tape tinned copper drain wire
4. OUTER SHEATH SHF2 thermoset compound halogen free & MUD resistant
PAIR / TRIPLE IDENTIFICATION
pair black light blue
triple light blue black brown pairs / triples progressively numbered
sheath colour grey
blue for intrinsically safe SHEATH MARKING
CCI BU (i) 250 V n x p(trp) x s mm2 NEK 606 IEC 60331-21 QA ref metric marking
BU (i) 250 Volt Nominal dimensional and electrical data 250 Volt
CONSTRUCTION INSULATION OVERALL WEIGHT CONDUCTOR
THICKNESS DIAMETER (APPROX) RESISTANCE
(APPROX) AT 20 Deg C
(mm) (mm) (mm) (kg/km) Ohm/km
1 pair 0,75 0,8 8,5 105 26,6002 pair 0,75 0,8 13,5 225 26,6004 pair 0,75 0,8 15,0 325 26,6008 pair 0,75 0,8 20,0 610 26,60012 pair 0,75 0,8 24,0 875 26,60016 pair 0,75 0,8 27,0 1075 26,60024 pair 0,75 0,8 33,0 1610 26,600
1 pair 1,5 0,8 9,5 145 12,2002 pair 1,5 0,8 14,5 305 12,2004 pair 1,5 0,8 17,0 465 12,2008 pair 1,5 0,8 23,0 850 12,20012 pair 1,5 0,8 28,0 1250 12,20016 pair 1,5 0,8 31,0 1575 12,20024 pair 1,5 0,8 38,5 2350 12,200
1 triple 0,75 0,8 9,5 130 26,6002 triple 0,75 0,8 14,5 255 26,6004 triple 0,75 0,8 17,0 395 26,6008 triple 0,75 0,8 22,0 745 26,60012 triple 0,75 0,8 27,0 1080 26,60016 triple 0,75 0,8 29,5 1385 26,60024 triple 0,75 0,8 36,5 2040 26,600
1 triple 1,5 0,8 10,5 175 12,2002 triple 1,5 0,8 15,5 375 12,2004 triple 1,5 0,8 19,0 580 12,2008 triple 1,5 0,8 25,0 1090 12,20012 triple 1,5 0,8 30,5 1635 12,20016 triple 1,5 0,8 35,0 2050 12,20024 triple 1,5 0,8 42,5 3055 12,200
IEC 60331 FIRE RESISTANT TEST
28
Generals
GeneralsSome parameters affecting operational chacteristics of the cablesmentioned in this catalog
CONDUCTOR RESISTANCEIt is the most important parameter of the conductor sizing related to:ρ conductor resistivity [Ω / mm 2/m]l conductor length [km]A cross area [mm 2]t temperature [Deg C]f frequency [Hz]
For low frequencies, conductor resistance is equal to DC condition.
R = ρ • l / A [Ω]
Temperature influence is calculated as:
Rt = R20 (234,5 + t) / 254,5 [Ω]
where:Rt conductor resistance [Ω]R20 conductor resistance at 20 Deg C [Ω]t conductor temperature [Deg C]Conductor resistance increases with frequency.
INSULATION RESISTANCEIt’s a peculiar characteristic of the insulation material.An higher value of insulation resistance means larger insulating capacityof the insulation.The "insulation resistance constant Ki" is calculated from the measuredinsulation resistance by the following formula:
Ki = l • R • 10-11 / (log10D / d) [MΩ • km]
where:R measured insulation resistance [Ω]l length if the cable [m]D outer diameter of the insulation [mm]d inner diameter of the insulation [mm]
39
REACTANCEIn a cable operating in a.c. it is related mainly to axial distance betweenconductors.For 2 - 3 - 4 conductors the reactance per phase could be calculated as:
X = 2 • π • f • L • I [Ω]
f frequency [Hz]L Induction [H/m]l core length [m]L Induction Is calculates as follows:
L = 0,2 [(ln 2a / d) + 0.25] • 10-6 [H/m]
a distance between cores [mm]d core diameter [mm]
MEDIUM VOLTAGE CABLES - REACTANCE
IMPEDANCEZ = √ (R2 + X2) [Ω]
R resistance [Ω]X reactance [Ω]
40
CROSS SECTION SINGLE CORE [Ω/km] THREE CORES [Ω/km]
[mm2] 50 Hz 60 Hz 50 Hz 60 Hz
25 0.147 0.177 0.119 0.14335 0.145 0.174 0.116 0.13950 0.137 0.165 0.108 0.13070 0.130 0.156 0.102 0.12295 0.118 0.142 0.097 0.116
120 0.114 0.137 0.095 0.114150 0.108 0.130 0.092 0.110185 0.107 0.129 0.089 0.107240 0.106 0.127 — —300 0.086 0.103 — —
MUTUAL CAPACITANCELow mutual capacitance causes small distorsion of the signal.Digital signal transmissions are sensible to this features. Is affected by:- type of conductor construction (increasing of conductor size means
larger capacitance)- insulation thickness (inversely proportional)
ATTENUATIONIt is defined as the decreasing, in signal amplitude, over the total length ofthe cable. Its value increases with the frequency increasing.Minimizing the attenuation means long distance transmission withoutamplification and no distorsions.
INTERFERENCESAre defined as all the noises influencing the signal transmission.They are produced internally the cable (i.e. cross talk) and externally (i.e.power equipments or HF generators).Both can be reduced by using suitable screenings.
INSTRUMENTATION AND TELECOMMUNICATION CABLESELECTRICAL CHARACTERISTICS
41
INDUCTANCEMUTUAL CAPACITANCE LOOP
SIZE (approx)max (approx) RESISTANCE
[mm2][mH/km]
[nF/km] max (approx)
individual screen common screen [Ω/km]
0.75 0.72 < 100 < 95 50.41.0 0.69 < 110 < 100 37.11.5 0.66 < 120 < 110 24.2
CURRENT DETERMINATION according to power and voltageIn case of three-phase systems, determination of the current Intensityrelated to power and voltage can be easily calculated by using:
I = 722 kW / V I = 578 kVA / V I = 531 HP / V
where
I = current intensity [A]V = rated voltage [V]kW = power(cos ϕ = 0.8) [kW]kVA = power [kVA] HP = horse power [HP]
VOLTAGE DROP (up to 1 kV)
∆V = K • I • L / 1000 [V]
I rated current [A]L electric line length [m]K see following table
nominal K
size 2 cores 3 cores 3 cores (three-foil format.)
[mm2] cos ϕ =1 cos ϕ = 0.8 cos ϕ =1 cos ϕ = 0.8 cos ϕ =1 cos ϕ = 0.8
1.0 45.00 36.10 39.00 31.30 38.30 30.801.5 30.20 24.30 26.10 21.00 25.70 20.702.5 18.20 14.70 15.70 12.70 15.40 12.504.0 11.40 9.210 9.850 7.980 9.650 7.8706.0 7.560 6.160 6.540 5.340 6.420 5.280
10.0 4.550 3.730 3.940 3.240 3.870 3.22016.0 2.870 2.390 2.480 2.070 2.440 2.07025.0 1.810 1.550 1.570 1.340 1.540 1.34035.0 1.310 1.140 1.130 0.988 1.110 0.99350.0 0.967 0.866 0.838 0.750 0.820 0.76070.0 0.669 0.624 0.579 0.541 0.568 0.55595.0 0.484 0.476 0.419 0.412 0.410 0.428
120.0 0.383 0.394 0.332 0.342 0.325 0.358150.0 0.314 0.341 0.272 0.295 0.265 0.308185.0 0.251 0.289 0.217 0.250 0.213 0.265240.0 0.193 0.245 0.167 0.212 0.163 0.224300.0 0.156 0.215 0.135 0.186 0.132 0.198
42
US / METRIC CROSS SECTION CONVERSION TABLE
43
Metric Standard metric
AWG (U.S.) cross-section cross-section(mm2) (mm2)
20 0.519 0.7518 0.823 116 1.31 1.514 2.08 2.512 3.31 410 5.26 68 8.37 106 13.30 164 21.15 252 33.62 351 42.41 50
1/0 53.49 702/0 67.23 703/0 85.01 954/0 107.2 120— — —— — —
Metric Standard metric
MCM (U.S.) cross-section cross-section(mm2) (mm2)
250 126.7 150300 152.0 150350 177.3 185400 202.7 185450 228.0 240500 253.4 300550 278.7 300600 304.0 300650 329.4 300700 354.7 400750 380.0 400800 405.4 400850 430.7 400900 456.0 500950 481.4 5001000 506.7 5001250 633.4 630
CCI - NEK 606 Offshore Cables - REV 0 11.00