Upload
jabiribm
View
16
Download
2
Embed Size (px)
DESCRIPTION
Octagonal pole Drawing
Citation preview
400050006000700080009000100001100012000
707070707070709090
130130130130135155175210240
030303030303030303
4X16 ON P.C.D-1754X16 ON P.C.D-1754X16 ON P.C.D-1754X20 ON P.C.D-1754X20 ON P.C.D-1904X20 ON P.C.D-2104X25 ON PCD-2254X25 ON P.C.D-2604X27 ON P.C.D-290
200X200X12200X200X12220X220X12220X220X12225X225X16260X260X16275X275X16300X300X20320X320X20
VL 4.0 PVL 5.0 PVL 6.0 PVL 7.0 PVL 8.0 PVL 9.0 PVL 10.0 PVL 11.0 PVL 12.0 P
L
d
H
TOP A/F OUTSIDE
BRACKET FORELEC.BOARD MTG.
DOOROPENING
D
REGULAROCTAGONAL
T1
STIFENER PLATE(X4)
BOTTOM A/F (OUT SIDE)
T
d
L
TECHNICAL SPECIFICATION OF OCTAGONAL POLES
SEC C - C VIEW FROM TOP OF THE POLE
PCD of Bolts
Top Dia -' TD 'Bottom Dia-'BD'Suitable Slotsfor FoundationBolts
'' B ''
'' L '
'
DIMENSION OF OCTOGONAL POLE WITH BASE PLATE FOUNDATION TYPEFOR MAXIMUM WIND SPEED OF 180 Km/h
Series Pole (P)
Abbreviation: H=Total height, T1=Sheet thickness, D=Door Opening, L=Foundation Bolt Length, d=Bolt Diameter
VE
NT
UR
A
www.venturalighting.comEmail.: [email protected]
Sales Office :- C-33, East of Kailash, New Delhi-110065, Tel.: 011-26842693 Fax : 91-11-26842693Photometric Centre:- 142 A/1, NSEZ, NOIDA
Works :- 136, Industrial Area, Malanpur, (Ghirongi) Distt. Bhind, (MP)
VENTURA LIGHTING LIMITEDSubsidiary of
VENTURA LIGHTING AND INFRATECH LIMITED
Pole Height Total Height - 'H' Thickness (T1)
Base Plate {LxBxT)
Foundation BoltDetail
ISO 9001 REGISTERED
www.jas-anz.com.au/registerSCB CIVENTURA LIGHTING
Base Dia - "BD"Top Dia - "TD"