Upload
wisnu
View
221
Download
0
Embed Size (px)
Citation preview
8/11/2019 NZ Products Guide Power Management
1/21375EATON CORPORATION New Zealand Product Guide
Power
ManagementMetering ..............................................................................................................................376-390
Analogue Panel Meters - Circutor ............................................................................................................................................ 377
Digital Meters - Circutor ............................................................................................................................................................ 381
Power Analyser - Circutor ..........................................................................................................................................................381
Energy Meters - Circutor ........................................................................................................................................................... 383
Current Transformers - Circutor .................................................................................................................................................385
Portable Power Analysers - Circutor .......................................................................................................................................... 388
Industrial Earth leakage Protection............................................................................................................................................ 388Earth Leakage Transformers ...................................................................................................................................................... 389
Metering Devices - Eaton ......................................................................................................................................................... 389
Power Factor Correction Components ...................................................................................... 391Power Factor Correction Components ...................................................................................................................................... 391
Solar Power Solutions ........................................................................................................ 392-395Solar Power Solutions Domestic, commercial & industrial ....................................................................................................... 393
8/11/2019 NZ Products Guide Power Management
2/21376 EATON CORPORATION New Zealand Product Guide
Power ManagementMetering
Metering
Over 30 years experience in energy management & power quality
Offering a comprehensive range of products - Measurement & Control equipment,
Industrial electrical protection, Power factor correction & Harmonic filtering
High-End Energy
ManagementSolutions
8/11/2019 NZ Products Guide Power Management
3/21377
Power Management
EATON CORPORATION New Zealand Product Guide
Metering
Metering
Voltmeters - AC Moving Iron 90, Direct Connection E1
Size (mm) Model No.
Volts Direct
Connection Scale Item No.
48 x 48 EC48 250V 0 - 250V M10415
300V 0 - 300V M10416
400V 0 - 400V M10417
500V 0 - 500V M10418
600V 0 - 600V M10419
72 x 72 EC72 250V 0 - 250V M10425
300V 0 - 300V M10426
400V 0 - 400V M10427
500V 0 - 500V M10428
600V 0 - 600V M10429
96 x 96 EC96 250V 0 - 250V M10435
300V 0 - 300V M10436
400V 0 - 400V M10437
500V 0 - 500V M10438
600V 0 - 600V M10439
144 x 144 EC144 250V 0 - 250V M10445
300V 0 - 300V M10446
400V 0 - 400V M10447
500V 0 - 500V M10448
600V 0 - 600V M10449
Voltmeters - AC Moving Iron with 3 Position Switchfor Phase to Phase Measurement, Direct Connection E1
Size (mm) Model No.
Volts Direct
Connection Scale Item No.
72 x 72 EC72FIII 500V 3 Phase M10628
96 x 96 EC96FIII 500V 3 Phase M10638
Voltmeters - AC Moving Iron with 6 Position Switchfor Phase to Phase and Phase to Neutral
Measurement, Direct Connection E1
Size (mm) Model No.
Volts Direct
Connection Scale Item No.
72 x 72 EC72FNIII +N 500 Volts 3 Phase &
Neutral
M10728
96 x 96 EC96FNIII +N 500 Volts 3 Phase &
Neutral
M10738
ote:N For 1.2P over-scale setting consult our sales staff. Other ratings available on request.
Ammeters - AC Moving Iron 90, Direct Connection E1
Size (mm) Model No.
Volts Direct
Connection Over Scale Item No.
48 x 48 EC48 5A 515 M10212
10A 1030 M10213
30A 3090 M10217
40A 40120 M10218
50A 50150 M10219
60A 60180 M1021A
72 x 72 EC72 5A 515 M10222
10A 1030 M10223
30A 3090 M10227
40A 40120 M10228
50A 50150 M10229
60A 60180 M1022A
75A 75 225 M1022B
100A 100 300 M1022C
96 x 96 EC96 5A 515 M10232
10A 1030 M10233
30A 3090 M10237
40A 40120 M10238
50A 50150 M10239
60A 60180 M1023A
75A 75 225 M1023B
100A 100 300 M1023C
ote:N For 1P or 5P over-scale setting consult our sales staff. Other ratings available on
request.
Analogue Panel Meters - Circutor
Voltmeters - AC Moving Iron 90
Accuracy Class 1.5, 1P Over-scalePanel Mount
For measuring the true RMS value of voltages ¤ts in A.C. networks. The moving iron systemis formed by two irons, one fixed, the other isattached to the indicating pointer through a shaft.The arc of the moving iron depends on the currentflow by the coil. The braking, that eliminates overshooting is produced by the action of siliconviscous fluid.
Ammeters - AC Moving Iron 90
Accuracy Class 1.5, 2P Over-scalePanel Mount
For measuring the true RMS value of voltages ¤ts in A.C. networks.
The moving iron system is formed by two irons,one fixed, the other is attached to the indicatingpointer through a shaft. The arc of the movingiron depends on the current flow by the coil. Thebraking, that eliminates over shooting is producedby the action of silicon viscous fluid.
Frequency 20 - 100Hz Range Temperature 20 C +/- 10 C
Consumption 1.8VA for 250Vac IP rating 52
3.3VA for 500Vac Overload 1.5 Un Continuous
InsulationVoltage
2kV for 1 min between internalmachinery & case
Frequency 20 - 100Hz Range Temperature 20 C +/- 10 C
Consumption 0.7VA for 1 Amp IP rating 52
1.2 VA for 5 Amp Overload 1.2 Un Continuous
Insulation
Voltage
2kV for 1 min between internal
machinery & case
8/11/2019 NZ Products Guide Power Management
4/21378
Power Management
EATON CORPORATION New Zealand Product Guide
Ammeters - AC Moving Iron 90
(for complete unit, please include SEC72 scale) Size: 72mm x 72mm E1
Amps CT Connection
Ammeter Scales
(Variable) Model No. Item No.
50A to 5000A /5A Refer SEC72 EC72 M10220
Ammeter Scales - SEC72 E1
Amps CT Connection
Scales for
EC72 Ammeter Item No.
50/5 50A M102Y9
60/5 60A M102YA
75/5 75A M102YB
100/5 100A M102YC
125/5 125A M102YD
150/5 150A M102YE
200/5 200A M102YF
250/5 250A M102YG
300/5 300A M102YH
400/5 400A M102YJ
500/5 500A M102YK
600/5 600A M102YL
750/5 750A M102YM
800/5 800A M102YN
1000/5 1000A M102YP
1200/5 1200A M102YQ
1500/5 1500A M102YR
2000/5 2000A M102YS
2500/5 2500A M102YT
3000/5 3000A M102YU
4000/5 4000A M102YV
5000/5 5000A M102YW
ote:N For 1P or 5P over-scale setting consult our sales staff.
External CT required.
Ammeters - AC Moving Iron 90
(for complete unit, please include SEC96 scale) Size: 96mm x 96mm E1
Amps CT Connection
Ammeter Scales
(Variable) Model No. Item No.
50A to 5000A /5A Refer SEC96 EC96 M10230
Ammeter Scales - SEC96 E1
Amps CT Connection
Scales for
EC96 Ammeter Item No.
50/5 50A M102X9
60/5 60A M102XA
75/5 75A M102XB
100/5 100A M102XC
125/5 125A M102XD
150/5 150A M102XE
200/5 200A M102XF
250/5 250A M102XG
300/5 300A M102XH
400/5 400A M102XJ
500/5 500A M102XK
600/5 600A M102XL
750/5 750A M102XM
800/5 800A M102XN
1000/5 1000A M102XP
1200/5 1200A M102XQ
1500/5 1500A M102XR
2000/5 2000A M102XS
2500/5 2500A M102XT
3000/5 3000A M102XU
4000/5 4000A M102XV
5000/5 5000A M102XW
ote:N For 1P or 5P over-scale setting consult our sales staff.
External CT required.
Analogue Panel Meters - Circutor
Ammeters - 72mm x 72mm
Accuracy Class 1.5, 2P Over-scalePanel Mount
For measuring the true RMS value of voltages& currents in A.C. networks.
The moving iron system is formed by two irons,one fixed, the other is attached to the indicatingpointer through a shaft.
The arc of the moving iron depends on thecurrent flow by the coil. The braking, thateliminates over shooting is produced by theaction of silicon viscous fluid.
Ammeters - 96mm x 96mm
Accuracy Class 1.5, 2P Over-scalePanel Mount
For measuring the true RMS value of voltages ¤ts in A.C. networks.
The moving iron system is formed by two irons,one fixed, the other is attached to the indicatingpointer through a shaft.
The arc of the moving iron depends on thecurrent flow by the coil. The braking, thateliminates over shooting is produced by the
action of silicon viscous fluid.
Frequency 20 - 100Hz Range Temperature 20 C +/- 10 C
Consumption 0.7VA for 1 Amp IP rating 52
1.2 VA for 5 Amp Overload 1.2 Un Continuous
Insulation
Voltage
2kV for 1 min between internal
machinery & case
Frequency 20 - 100Hz Range Temperature 20 C +/- 10 C
Consumption 0.7VA for 1 Amp IP rating 52
1.2 VA for 5 Amp Overload 1.2 Un Continuous
Insulation
Voltage
2kV for 1 min between internal
machinery & case
Metering
Metering
8/11/2019 NZ Products Guide Power Management
5/21379
Power Management
EATON CORPORATION New Zealand Product Guide
Ammeters - AC Moving Iron with 3 Position Switch
for L1, L2 & L3 Phase Measurement
(for complete unit, please include SEC72FA scale) Size: 72mm x 72mm E1
Amps CT Connection
Ammeter Scales
(Variable) Model No. Item No.
50A to 5000A /5A Refer SEC72FA EC72FA M10521
Ammeter Scales - SEC72FA E1
Amps CT Connection
Scales for
EC72FA Ammeter Item No.
50/5 50A M105Y9
60/5 60A M105YA
75/5 75A M105YB
100/5 100A M105YC
125/5 125A M105YD
150/5 150A M105YE
200/5 200A M105YF
250/5 250A M105YG
300/5 300A M105YH
400/5 400A M105YJ
500/5 500A M105YK
600/5 600A M105YL
750/5 750A M105YM
800/5 800A M105YN
1000/5 1000A M105YP
1200/5 1200A M105YQ
1500/5 1500A M105YR
2000/5 2000A M105YS
2500/5 2500A M105YT
3000/5 3000A M105YU
4000/5 4000A M105YV
5000/5 5000A M105YW
ote:N For 5P over-scale setting consult our sales staff.External CT required.
Ammeters - AC Moving Iron with 3 Position Switch
for L1, L2 & L3 Phase Measurement
(for complete unit, please include SEC96FA scale) Size: 96mm x 96mm E1
Amps CT Connection
Ammeter Scales
(Variable) Model No. Item No.
50A to 5000A /5A Refer SEC96FA EC96FA M10531
Ammeter Scales - SEC96FA E1
Amps CT Connection
Scales for
EC72FA Ammeter Item No.
50/5 50A M105X9
60/5 60A M105XA
75/5 75A M105XB
100/5 100A M105XC
125/5 125A M105XD
150/5 150A M105XE
200/5 200A M105XF
250/5 250A M105XG
300/5 300A M105XH
400/5 400A M105XJ
500/5 500A M105XK
600/5 600A M105XL
750/5 750A M105XM
800/5 800A M105XN
1000/5 1000A M105XP
1200/5 1200A M105XQ
1500/5 1500A M105XR
2000/5 2000A M105XS
2500/5 2500A M105XT
3000/5 3000A M105XU
4000/5 4000A M105XV
5000/5 5000A M105XW
ote:N For 5P over-scale setting consult our sales staff.External CT required.
Analogue Panel Meters - Circutor
Ammeters - 72mm x 72mm
Accuracy Class 1.5, 1P Over-scalePanel Mount
For measuring the true RMS value of voltages& currents in A.C. networks.
The moving iron system is formed by two irons,one fixed, the other is attached to the indicatingpointer through a shaft.
The arc of the moving iron depends on thecurrent flow by the coil. The braking, thateliminates over shooting is produced by theaction of silicon viscous fluid.
Ammeters - 96mm x 96mm
Accuracy Class 1.5, 1P Over-scalePanel Mount
For measuring the true RMS value of voltages& currents in A.C. networks.
The moving iron system is formed by two irons,one fixed, the other is attached to the indicatingpointer through a shaft.
The arc of the moving iron depends on thecurrent flow by the coil. The braking, thateliminates over shooting is produced by the
action of silicon viscous fluid.
Frequency 20 - 100Hz Range Temperature 20 C +/- 10 C
Consumption 0.7VA for 1 Amp IP rating 52
1.2 VA for 5 Amp Overload 1.2 Un Continuous
Insulation
Voltage
2kV for 1 min between internal
machinery & case
Frequency 20 - 100Hz Range Temperature 20 C +/- 10 C
Consumption 0.7VA for 1 Amp IP rating 52
1.2 VA for 5 Amp Overload 1.2 Un Continuous
Insulation
Voltage
2kV for 1 min between internal
machinery & case
Metering
Metering
8/11/2019 NZ Products Guide Power Management
6/21380
Power Management
EATON CORPORATION New Zealand Product Guide
Bi-Metallic Maximeter Ammeters(for complete unit, please include SMC96 scale)
Size: 96mm x 96mm Scale 90 degrees P1.2 E1
Amps CT Connection
Ammeter Scales
(Variable) Model No. Item No.
1002000 Amps
/5A
Refer SMC96 MC96 M12231
Bi-Metallic Maximeter Ammeter Scales - SMC96 E1
Amps CT Connection
Scales for
EC96FA Ammeter Item No.
100/5 100A M122XC
200/5 200A M122XF
300/5 300A M122XH
400/5 400A M122XJ
500/5 500A M122XK
600/5 600A M122XL
750/5 750A M122XM
800/5 800A M122XN
1000/5 1000A M122XP
1500/5 1500A M122XR
2000/5 2000A M122XS
Bi-Metallic Maximeter + Moving Iron Ammeter(for complete unit, please include SEMC96 scale)
Size: 96mm x 96mm Double Scale 90 degrees class 3/1.5 P1.2/P2 E1
Amps CT Connection
Ammeter Scales
(Variable) Model No. Item No.
1002000 Amps
/5A
Refer SEMC96 EMC96 M12632
Ammeter Scales - SEMC96 E1
Amps CT Connection
Scales for
MC96 Ammeter Item No.
100/5 100A M126XC
200/5 200A M126XF
300/5 300A M126XH
400/5 400A M126XJ
500/5 500A M126XK
600/5 600A M126XL
750/5 750A M126XM
800/5 800A M126XN
1000/5 1000A M126XP
1500/5 1500A M126XR
2000/5 2000A M126XS
ote:N For other inertia times consult our sales staff.
Pointer Type Frequency Meters E1
Frequency Hz Class Size (mm) Model No. Item No.
45 - 55 Hz 0.5 48 x 48 HC48 M12711
45 - 55 Hz 0.5 72 x 72 HC72 M12721
45 - 65 Hz 0.5 72 x 72 HC72 M127210040
45 - 55 Hz 0.5 96 x 96 HC96 M12731
45 - 55 Hz 0.5 144 x 144 HC144 M12741
ote:N Other Frequency ranges & voltages available on request.
Hour Run Time Meters
A synchronous motor driven device that registers inincrements of 0.01 hours for measuring operating orrunning time of electrical equipment or machines.
CH Series E1
Size Voltage Frequency Item No.
48mm x 48mm 240 50Hz M14911
72mm x 72mm 240 50Hz M14921
96mm x 96mm 240 50Hz M14931
Analogue Metering Accessories E1
Description Item No.
Terminal Covers EC 72 M19922
Terminal Covers EC 96 M19923
Terminal Covers EC 144 M19924
IP65 Front Protective Boot 48x48 M19941
IP65 Front Protective Boot 72x72 M19942
IP65 Front Protective Boot 96x96 M19943
IP65 Front Protective Boot 144x144 M19944
Analogue Panel Meters - Circutor
Bimetallic Maximeters
Inertia Time: 15 MinutesPanel Mount
For measuring long time overloads of equipment.The current needle measures the load current, while theother measures changes due to temperature.
Frequency Meters
Accuracy Class 0.5Panel Mount
System of 90 moving coil & electronic converter circuit
built into same unit.
Designed for an easy & quick reading of frequency in A.C.units. The distortion of the voltage can reach up to 15% ofthe rated voltage of the third harmonic without effectingthe accuracy.
Frequency 0 - 1000Hz Range
Consumption 3.25 VA
Temperature 20 C +/- 10 C
IP rating 52
Insulation Voltage 2kV for 1 min between internal machinery & case
Frequency 50 - 400Hz Range Temperature 20 C +/- 10 C
Consumption 2 to 3 VA IP rating 52
Overloads 1.2 Un continous
Insulation Voltage 2kV for 1 min between internal
machinery & case
Metering
Metering
8/11/2019 NZ Products Guide Power Management
7/21381
Power Management
EATON CORPORATION New Zealand Product Guide
DM45 Series E1
Description Range Model No. Item No.
Voltmeter 0 - 600 Volts DM45-V M20901
Ammeter (Direct) 0 - 30 Amps DM45-AD M20921
Ammeter (Indirect) /5 Amps DM45-A M20911
Frequency Meter 10 - 600 Hertz DM45-F M20931
Analyser - (V, Hz,
THD, A) (Direct*)
600V, 30A, 600Hz DM45-CMD M20951
Analyser (V, Hz, THD,
A) (Indirect*)
600V, /5A, 600Hz DM45-CM M20941
* Model supplied with relay output.
Power Meters CVM-MINI Series
The CVM-MINI is an instrument which measures,calculates & displays the main electrical parametersfor three-phase industrial systems (balanced orunbalanced). Measurements are in true effectivevalue, via three AC voltage inputs & three AC currentinputs.
Other features include:
Current measuring .../5 or .../1A
DIN rail format with only 3 modules
Assembly on the 72 x 72mm panelwith frontal adaptor (M5ZZF1)
RS-485 Communications (Modbus-RTU)
Two transistor outputs
Sealable
CVM Mini E1
Model
ItemNo.
CVM-MINI - - - - M52000
CVM-MINI ITF - - - - M52010
CVM-MINI ITFRS458 C2
2 - M52021
CVM-MINI ITF-
HAR-RS458 C2
2 M52031
CVM-MINI
Panel Adapter
- - - - - - - - - - - - M5ZZF1
Three-phase
TrueRMSvalue
Insulatedinput
Energymeter
THD(V,A
)
Digitaloutput
Powerdemand
Harmonic
LCD
RS485
ModbusRTU
/1Aor/5ATransformer
CVMk2 E1
Description Model No. Item No.
CVMk2 modular power analyzer 3 phase Modbus RTU
RS485 Class 0.5
CVMk2-ITF-405 M54400
CVMk2 modular power analyser 3 phase Modbus RTU
RS485 Class 0.2
CVMk2-ITF-402 M54402
CVMk2 3 phase class 0.5 measurement module only M-CVMk2-ITF-405 M54410
CVMk2 3 phase class 0.2 measurement module only M-CVMk2-ITF-402 M54412
CVMk2 display only D-CVM-K2 M54420
Expansion Modules for CVMk2 E1
Type
Outputs
512MBMemory
DigitalI/O
AnalogueI/O
Com
ItemNo.
k2-EXP-8I/8O-Digital-TR Trans. - 8/8 - - M54501
k2-EXP-8I/4O-Analogue - - - 8/4 - M54502
k2-EXP-8I/4O-Digital-RL Relay - 8/4 - - M54503
k2-EXP-SD-MODBUS/TCP - - - M54504
k2-EXP-SD-Memory -
- - - M54506
CVMBD DIN Rail Power Analyser
Din rail mount (8 modules) power analyserfor balanced & unbalanced three phasesystems, current reading /1A or /5A, harmonicmeasurements, different protocols, three linebacklit LCD display, Internal clock, Compatible withPOWER STUDIO, includes special communicationsport (RED) that can be interfaced with peripheralson page 5-15.
E1
Description Model No. Item No.
Portable analyser with RS485& RED port
CVM BD-RED-H M52110
Digital Meters - Circutor
Digital Meters DM45
Din Rail mounted & fullyprogrammable relay. Can
be used as an alarm relay
& measures betweenphase & neutral (V, A,Hz, THD). Stores in itsinternal memory minimum- maximum values in caseof power failure. Maximumdemand integration time can be programmed & has password protection.
Power Analyser - Circutor
CVMk2 Modular Power Analyzer
The CVMk2 Series is a modularprogrammable power meter that measures
more than 300 electrical parameters
of balanced or unbalanced three-phaseelectrical networks. All measurements aretrue RMS values & 4C, that are sourced bymeans of three A.C. voltage inputs & threeA.C. Current inputs via/5Amp currenttransformers. Unit is composed of measuringmodule & display module. It can be panelmounted: 144 x 144, 96 x 96 & round profile.
CVM-MINI Series
Metering
Metering
CVMk2
CVM BD-RED-H
8/11/2019 NZ Products Guide Power Management
8/21
8/11/2019 NZ Products Guide Power Management
9/21383
Power Management
EATON CORPORATION New Zealand Product Guide
Energy Meters - Circutor
Electrical Energy Meters
The consumption of energy can become difficult to measure in situations of multiple loads& different tariffs.
Circutor is able to offer a complete solution.The product range includes single phase digital & mechanical meters that can measureconsumption at pre-determined locations to control each sector of the project. Three phaseactive & reactive electronic meters are also available for monitoring the different electricalservices, or machines that may be installed within the facility.
Once coupled together by a pulse centralisation unit & connected to a PC the Easycommsoftware provides monitoring & recording of consumption data for control, collation &billing.
MKT20-400 MKD-ITF-C2
Single Phase Energy Meters, Direction Connection, DIN Rail Mounting E1
Description Model No. Item No.
EMS30C 1-Phase kW.h 5A (max. 30A) Mechanical 1 Module EMS30C M31611
EM 30-C 1-Phase kW.h 5A (max. 30A) Mechanical 2 Module EM30C M30811
MK30 M 1-Phase kW.h 30A (max. 60A) Mechanical 4 Module MK30M M30110
MK60 M 1-Phase kW.h 60A (max. 120A) Mechanical 4 Module MK60M M30210
MK30-LCD 1-Phase kW.h 30A (max. 60A) Digital MK30-LCD M30120
MK30-LCD-RS485 1-Phase kW.h 30A (max. 60A) Digital w/ RS485 MK30-LCD-RS485 M30121
MK60-LCD 1-Phase kW.h 60 A (max. 120A) Digital MK60-LCD M30220
MK60-LCD-RS485 1-Phase kW.h 60A (max. 120A) Digital w/ RS485 MK60-LCD-RS485 M30221
Three Phase Energy Meters, Direction Connection, DIN Rail Mounting E1
Description Tariff Model No. Item No.
MKT-20-400V three-ph kW.h 20A (mx.60A), Mechanical 1 MKT20-400 M30610
MKT-40-400V three-ph kW.h 40A (mx.120A), Mechanical 1 MKT40-400 M30620
MKB 363M-400V phase-phase kW.h 63A, Mechanical 1 MKB363M M30310
MKT2 20-400V three-ph kW.h 20A (mx.60A), Mechanical 2 MKT2-20-400 M30611
MKT2 40-400V three-ph kW.h 40A(mx.120A), Mechanical 2 MKT2-40-400 M30621
MKD-ITF-C2 three-ph meter 4 quadrant 40A(mx.120A) Digital 1 MKD-ITF-C2 M33000
MKD-ITF-RS485-I2-C2 three-ph 4 quadrant 40A(mx.120A) Digital + RS485 3 MKD-ITF-RS485-I2-C2 M33011
Three Phase Energy Meters, External Current Transformers E1
Description Tariff Model No. Item No.
CEP96 3-ph kW.h Digital Energy Meter.../5A Panel Mount - CEP-96 M30701
EDMk-ITF-C2 3-ph Digital Energy KWh/KVAR DIN Rail 1 EDMk-ITF-C2 M31741
EDMk-ITF-C2 3-ph Digital Energy Meter c/w Battery 1 EDMk-ITF-C2 M317410000030
EDM3k-ITF-C2 3-ph Digital Energy Meter KWh/KVARh 3 EDM3k-ITF-C2 M31743
EDMk-ITF-C2 3-ph Digital Energy Meter KWh/KVARh + RS485 1 EDMk-ITF-RS485 M31751
EDMk Panel Adapter - - M5ZZF1
Impulse Centralisation Units E1
Description Inputs Model No. Item No.
LM24-M, Pulse Concentrator (RS485, Modbus/RTU) 24 LM24-M M31520LM50-TCP 19200BPS CU Inputs = 50 (Ethernet input, Modbus/TCP protocol) 50 LM50-TCP M31531
LM4I/4O-M Centralisation Unit 4I/4O + RS485 (Modbus/RTU protocol) 4I/4O LM4I/4O-M M31563
Maximum Demand Controller, External Current Transformers E1
Description Model No. Item No.
CVM-R8CPP, Impulses power control CVM-R8CPP M60311
EDMk-ITF-C2 EMS30C MK60-LCD LM-24M CEP-96
Metering
Metering
8/11/2019 NZ Products Guide Power Management
10/21384
Power Management
EATON CORPORATION New Zealand Product Guide
Peripherals E1
Description Model No. Item No.
CVM-R8C + Control Program CVM-R8C M53502
CVM-R8A-D, 8 Analogue. Input 0-20 mA + 2 Analogue. Output + display CVM-R8A-D M53513
CVM-R10C, Expansion Peripheral (12 inputs + 10 relays) CVM-R10C M53600
Convertors E1
Description Model No. Item No.
RS-232/RS-485 Intelligent Converter (RTS control) RTS 232/485 M54020
Convertor USB-RS485 USB-RS485 M54040
RS485/Ethernet Modbus TCP convertor TCP2RS-TCP M54032
Software E1
Description Model No. Item No.
Power Studio Energy Monitoring & Control Software (Basic Package) POWERSTUDIO M90211
Power Studio Energy Monitoring & Control Software (Full Package) POWERSTUDIO SCADA M90231z
Power Studio Energy Monitoring & Control Software (Deluxe Version) POWERSTUDIO DELUXE M90241
Measuring Transducers E1
Description Model No. Item No.
A.C. Voltage (Aux. 240V, 50Hz) 0-600 Volt Input Range, 4-20mA Output CVE-A M25011
A.C. Current (Aux. 240V, 50Hz) .../5Amp Input, 4-20mA Output CCE-A M25111
Frequency (Aux. 240V, 50Hz) Selectable Input, Selectable Output, Network Voltage 50-600 Volts CFE M25511
Other transducers available on request. Please contact your Eaton representative for:- 3 Phase, Leakage Current, Active Power Reactive power, Power Factor & DC transducer & further options.
Energy Meters - Circutor
USB-RS485TCP2RS-TCPRTS 232/485 CVM-R8C
Metering
Metering
- Single-phase electronic meters, with digital
or mechanical display, measure energy
consumption in each area of your installation.
From metering of individual power outlets,
such as sockets for caravans on camp sites
or recharging batteries on quaysides, to
measuring excessive electricity consumption
in hotels, power supplies to displays in
department stores etc.
- Three-phase electronic active & reactive
energy meters, to measure electricity
consumed by three-phase circuits (individual
Electrical Measurement Solutions For Any
Application consumption by motors, bar
equipment, water pumps, etc.)
- Centralised systems, utilising a centralised
pulse module connected to a PC via an
RS-485 system or via Ethernet, give you total
control over electricity used by the above
meters or from any other source of pulses
(water meters, gas, etc.).
- Power quality meters that provide advanced
solutions for measuring power quality,
harmonics & transients.
For further Information:
0508 328 6669www.eaton.co.nz
Electrical Measurement SolutionsFor Any Application
Eaton & Circutor have electrical measurement solutions for any application.
8/11/2019 NZ Products Guide Power Management
11/21385
Power Management
EATON CORPORATION New Zealand Product Guide
Current Transformers - Circutor
Current Transformers
TC Series - Berg Series - Classes: 0.5, 1 or 3
The TC Series (Berg Range) is specifically designed for use in those places with a limited space, such as situations where there is minimum separation between busbars or circuit breakers.
E1
Type A Burden (VA) Primary Window Size (mm) Model No. Item No.
Class 0,5 Class 1 Class 3
TC 5
40/5 - - 1.50
PASSING BAR
Busbar:
25 x 5 mm
cable:n20 mm
70 x 58 TC 5 M70311
50/5 - - 3.00 70 x 58 TC 5 M70312
60/5 - 1.25 3.50 70 x 58 TC 5 M70313
75/5 - 2 3.50 70 x 58 TC 5 M70314
100/5 1.5 2.5 3.75 70 x 58 TC 5 M70315
125/5 1.75 3.5 5.00 70 x 58 TC 5 M70316
150/5 2.5 3.5 5.00 70 x 58 TC 5 M70317
200/5 3.75 5 5.00 70 x 58 TC 5 M70318
250/5 5 7.5 7.50 70 x 58 TC 5 M70319
TC 5.2
125/5 - 1.5 2
PASSING BAR
Busbar:
20 x 12mm,
25 x 10mm,
30 x 10mm
Cable:n22mm
70 x 58 TC 5.2 M70322
150/5 1 2 2.5 70 x 58 TC 5.2 M70323
200/5 2.5 3 3.5 70 x 58 TC 5.2 M70324
250/5 3.5 3.75 5 70 x 58 TC 5.2 M70325
300/5 3.5 3.75 5 70 x 58 TC 5.2 M70326
400/5 3.5 5 7.5 70 x 58 TC 5.2 M70327
500/5 5 7.5 10 70 x 58 TC 5.2 M70328
600/5 5 7.5 10 70 x 58 TC 5.2 M70329
TC 6.2
100/5 1.75 3.75 7.5
PASSING BAR
Busbar:
30 x 10 mm
cable:n26 mm
80.5 x 64 TC 6.2 M70341
125/5 3.75 7.5 10.00 80.5 x 64 TC 6.2 M70342
150/5 5 7.5 10.00 80.5 x 64 TC 6.2 M70343
200/5 7.5 10 10.00 80.5 x 64 TC 6.2 M70344
250/5 7.5 10 15.00 80.5 x 64 TC 6.2 M70345
300/5 10 10 15.00 80.5 x 64 TC 6.2 M70346
400/5 10 10 15.00 80.5 x 64 TC 6.2 M70347
500/5 15 15 20.00 80.5 x 64 TC 6.2 M70348
600/5 15 20 25.00 80.5 x 64 TC 6.2 M70349
TC 6
150/5 1 3.5 5.00
PASSING BAR
Busbar:
40 x 10 mm
cable:n28 mm
80.5 x 64 TC 6 M70331
200/5 3.5 5 7.5 80.5 x 64 TC 6 M70332
250/5 5 7.5 10 80.5 x 64 TC 6 M70333
300/5 5 7.5 10.00 80.5 x 64 TC 6 M70334
400/5 5 7.5 10.00 80.5 x 64 TC 6 M70335
500/5 7.5 10 15.00 80.5 x 64 TC 6 M70336
600/5 7.5 10 15.00 80.5 x 64 TC 6 M70337
750/5 10 15 20.00 80.5 x 64 TC 6 M70338
800/5 10 15 20.00 80.5 x 64 TC 6 M70339
TC 8
400/5 5 7.5 10.00
PASSING BAR
Busbar:
60 x 12 mm
cable:n44 mm
102 x 84.5 TC 8 M70361
500/5 7.5 10 15.00 102 x 84.5 TC 8 M70362
600/5 10 15 20.00 102 x 84.5 TC 8 M70363
750/5 15 20 25.00 102 x 84.5 TC 8 M70364
800/5 15 20 30.00 102 x 84.5 TC 8 M70365
1000/5 15 20 30.00 102 x 84.5 TC 8 M70366
1200/5 15 20 30.00 102 x 84.5 TC 8 M70367
1500/5 15 20 30.00 102 x 84.5 TC 8 M70368
1600/5 15 20 30.00 102 x 84.5 TC 8 M70369
Metering
Metering
8/11/2019 NZ Products Guide Power Management
12/21386
Power Management
EATON CORPORATION New Zealand Product Guide
Current Transformers - Circutor
TC Current Transformers
TC Series - Berg Series - Classes: 0.5, 1 or 3The TC Series (Berg Range) is specifically designed for use in those places with a limited space, such as situations where there is minimum separation between busbars or circuit breakers.
E1
Type A Burden & Accuracy Primary Window Size (mm) Model No. Item No.
TC 10
1000/5 10VA Class 0.5
PASSING BAR
Busbar:
80 x 30mm
cable:n63mm
130 x 108 TC 10 M70373
1200/5 10VA Class 0.5 130 x 108 TC 10 M70374
1600/5 15VA Class 0.5 130 x 108 TC 10 M70376
2000/5 15VA Class 0.5 130 x 108 TC 10 M70377
2500/5 15VA Class 0.5 130 x 108 TC 10 M70378
3000/5 15VA Class 0.5 130 x 108 TC 10 M70379
TC 12
1600/5 15VA Class 0.5
PASSING
BAR
Busbar:
3x100x10mm
150 x 129 TC 12 M70384
2000/5 15VA Class 0.5 150 x 129 TC 12 M70385
2500/5 20VA class 0.5 150 x 129 TC 12 M70386
3000/5 30VA class 0.5 150 x 129 TC 12 M70387
4000/5 35VA class 0.5 150 x 129 TC 12 M70388
Current Transformer - Accessories E1
Description Item No.
P19921
Accessory to mount the TC5, TC5.2, TC6, TC6.2 transformers on a DIN rail P19921
M79951
Accessory to seal the secondary side terminal on the TC type transformers M79951
TA Current Transformers
TA Series - Classes: 0.5, 1 or 3The TA Series of CT is designed for switchboard & panel manufacturers that require a flexible CT that is well suited to house busbar or cable (as nominated under the primary column).
E1
Type A Burden & Accuracy Primary Window Size (mm) Model No. Item No.
TA600
TA500
Sealable terminal cover,fixing base & fixing busbardevice included.
750/5 15 VA class 0.5
PASSING
BAR
Busbar:
100 x 20mm
187.5 x 95 TA 400 M70594
800/5 15 VA class 0.5 187.5 x 95 TA 400 M70595
1000/5 15 VA class 0.5 187.5 x 95 TA 400 M70596
1200/5 15 VA class 0.5 187.5 x 95 TA 400 M70597
1500/5 15 VA class 0.5 187.5 x 95 TA 400 M70598
2000/5 20 VA class 0.5 187.5 x 95 TA 400 M70599
1500/5 15 VA class 0.5
PASSING
BAR
Busbar:
100 x 30mm
202.5 x 115 TA 500 M705A4
2000/5 20 VA class 0.5 202.5 x 115 TA 500 M705A6
2500/5 20 VA class 0.5 202.5 x 115 TA 500 M705A7
3000/5 20 VA class 0.5 202.5 x 115 TA 500 M705A8
4000/5 35 VA class 0.5 202.5 x 115 TA 500 M705A9
1000/5 15 VA class 0.5
PASSING
BAR
Busbar:
125 x 60mm
196 x 124 TA 600 M705B1
1500/5 15 VA class 0.5 196 x 124 TA 600 M705B3
2000/5 15 VA class 0.5 196 x 124 TA 600 M705B5
2500/5 20 VA class 0.5 196 x 124 TA 600 M705B6
3000/5 30 VA class 0.5 196 x 124 TA 600M705B7
4000/5 35 VA class 0.5 196 x 124 TA 600 M705B8
5000/5 40 VA class 0.5 196 x 124 TA 600 M705B9
Metering
Metering
8/11/2019 NZ Products Guide Power Management
13/21387
Power Management
EATON CORPORATION New Zealand Product Guide
Current Transformers - Circutor
Current Transformers - Split Core
TP SeriesCircutor offer the most comprehensive range of Split C.T.s in providing flexibility for upgrading or retrofitting into existing switchboard assemblies.
E1
Type TP Split Core Series A Burden & Accuracy Primary Window Size (mm) Model No. Item No.
TP - 23
100/5 1.5 VA class 3
PASSING
BAR
Busbar:
20 x 30mm
110 x 89 TP - 23 M70111
150/5 2 VA class 3 110 x 89 TP - 23 M70112
200/5 1.5 VA class 1 110 x 89 TP - 23 M70113
250/5 2 VA class 1 110 x 89 TP - 23 M70114
300/5 1.5 VA class 0.5 110 x 89 TP - 23 M70115
400/5 2.5 VA class 0.5 110 x 89 TP - 23 M70116
TP - 58
250/5 1 VA class 0.5
PASSING
BAR
Busbar:
50 x 80mm
145 x 114 TP - 58 M70121
300/5 1.5 VA class 0.5 145 x 114 TP - 58 M70122
400/5 1.5 VA class 0.5 145 x 114 TP - 58 M70123
500/5 2.5 VA class 0.5 145 x 114 TP - 58 M70124
600/5 2.5 VA class 0.5 145 x 114 TP - 58 M70125
750/5 3 VA class 0.5 145 x 114 TP - 58 M70126
800/5 3 VA class 0.5 145 x 114 TP - 58 M70127
1000/5 5 VA class 0.5 145 x 114 TP - 58 M70128
TP - 88
250/5 1 VA class 0.5
PASSING
BAR
Busbar:
80 x 80mm
145 x 144 TP - 88 M70131
300/5 1.5 VA class 0.5 145 x 144 TP - 88 M70132
400/5 1.5 VA class 0.5 145 x 144 TP - 88 M70133
500/5 2.5 VA class 0.5 145 x 144 TP - 88 M70134
600/5 2.5 VA class 0.5 145 x 144 TP - 88 M70135
750/5 3 VA class 0.5 145 x 144 TP - 88 M70136
800/5 3 VA class 0.5 145 x 144 TP - 88 M70137
1000/5 5 VA class 0.5 145 x 144 TP - 88 M70138
TP - 812
500/5 4 VA class 1
PASSING
BAR
Busbar:
80 x 120mm
185 x 144 TP - 812 M70141
600/5 5 VA class 1 185 x 144 TP - 812 M70142
750/5 2.5 VA class 0.5 185 x 144 TP - 812 M70143
800/5 3 VA class 0.5 185 x 144 TP - 812 M70144
1000/5 5 VA class 0.5 185 x 144 TP - 812 M70145
1200/5 6 VA class 0.5 185 x 144 TP - 812 M70146
1250/5 7 VA class 0.5 185 x 144 TP - 812 M70147
1500/5 8 VA class 0.5 185 x 144 TP - 812 M70148
TP - 816
1000/5 10 VA class 0.5
PASSING
BAR
Busbar:
80 x 160mm
245 x 184 TP - 816 M70151
1500/5 15 VA class 0.5 245 x 184 TP - 816 M70152
2000/5 15 VA class 0.5 245 x 184 TP - 816 M70153
2500/5 15 VA class 0.5 245 x 184 TP - 816 M70154
3000/5 20 VA class 0.5 245 x 184 TP - 816 M70155
4000/5 20 VA class 0.5 245 x 184 TP - 816 M70156
5000/5 20 VA class 0.5 245 x 184 TP - 816 M70157
Metering
Metering
8/11/2019 NZ Products Guide Power Management
14/21388
Power Management
EATON CORPORATION New Zealand Product Guide
Portable Power Analysers - Circutor
Portable Power Analysers
AR5L Hand Held Series
The AR5L Series network analyser is a fully
programmable measuring instrument that measures& records in memory all the electrical parametersfrom any power system. These instruments areequipped with voltage & current channels to carryout the measurement of any parameter from eitherbalanced or unbalanced three-phase power systems.
Industrial Earth leakage Protection
Electronic Earth leakage Relays with external Transformer WN Series
An electronic industrial earth leakage protection relay that can offer protection & prevention.It is DIN Rail mounted & utilises external transformers WN Series.
E1
Type Item No.
RN-0,03 F F - P12101
RN-0,3 F F - P12111
RN-R1 A A P12131
RN-R A A P12132
RN-10 A A P12140
TrueRMSvalue
SensitivityF=FixedA=Adjustable
DelayF=FixedA=Adjustable
ClassASuperImmunised
HighFrequencyFiltering
LeakageIndication(LED)
ManualResetPowerFailure
ExternalTest
2ModulesDinRail
LeakageIndicationviaLED
MultiRangePowerSupply
Multi Function LCD Electronic industrial Earth Leakage protection Relays
Multifunction electronic industrial earth leakage protection relay that can offer protection,prevention & continuity. It utilises WG transformers, can be Din rail or panel mounted &
comes with LCD display & programmable sensitivity/delay.
E1
WN Series Item No.
RGU-10 - - 3 P11941
RGU-10C 3 P11944
TrueRMSvalue
DinRail/Panel
ClassASuperimmunised
DisconnectionBetween80-100
%o
fleakagecurrent
HighFrequencyFiltering
8/20MiSat5KA1.2
/50MiSat5KV
ProgramableSensitivity/Delay
RS485Communication
ManualResetPowerFailure
NRofModules
Accessory for panel mounting M5ZZF1.
AR.5L Series Power & Power Quality E1
Portable Analysers
Type Item No.
AR5L Kit 3L case
AR5L 1 MB inc. supply, wiring & harmonic program, carrying bag.
CPR-1000 clamp (3 x 1000 A)
CPR-500 (1 x 500 A)
POWER-VISION software
M80811
AR5L Kit 5L case
AR.5L 1 MB inc. supply, wiring & carrying bag.
CPR-1000 (1 x 1000A)
CP-5 clamp (3 x 5 A)
POWER-VISION software &
harmonics disturbances programs
M80832
C80 Portable Power Analyser
Measurement of the main electrical parametersof a single-phase network, balanced three-phasenetwork & unbalanced three-phase network with neutral.
Measurement of energy
Measurement of the THD in A & V
Detects leakage currents & the turning direction
of phases
Internal memory to record parameters automatically Display of the maximum & minimum values of
electrical parameters
Reduced size & weight (300g) very robust & easy to use
Auto-detection of clamp
C80 Series Power Analyser E1
Type Item No.
C80 / 1000 Kit includes:
C-80 analyser x 1
CPR-1000 clamp x 1
Voltage cable x 3 C-80 carry case x 1
M80121
C80 / 2000 Kit includes:
C-80 analyser x 1
CP2000/200 clamp x 1
Voltage cable x 3
C-80 carry case x 1
M80122
Other C-80 kits & accessories available on request.
WNS/WNAR5L
C80
RN Relay WG Series RGU - 10
MiS = micro second
Metering
Metering
ote:N Accessories included may vary according
to item numbers.
Portable Analyser Kit & Harmonics Applications
Calculates feeder cable
diameter required to support
losses due to harmonics
Studies the parameters for
harmonic filtering applications
Comparison of
measurements taken
according to IEC standards
Energy & tariff study
Consumption in the
system study
Analysis of reactive power
to be corrected
8/11/2019 NZ Products Guide Power Management
15/21389
Power Management
EATON CORPORATION New Zealand Product Guide
Earth Leakage Transformers
RGU10 Features
2 signalling LEDs
- ON / Fault trip
- Pre-alarm
RS-485 Communications (MODBUS
protocol) (*)
Display to monitor:- Sensitivity
- Delay time
- Instant leakage current
- Trip leakage current (red backlight
when trip occurs)
Test and Reset buttons
Breaking element status monitoringDisplay in TRMS:
- Instant leakage current.
- Trip leakage current.
Parameter setting via rotating menu.
5 buttons
WG Series Earth Leakage Transformers (supports RGU-10 Relay)
WG series can cover diameter range of 20mm up to 210mm protected against harmonics& disturbances. They support the RGU-10 relays.
WG Series E1
Type Description Item No.
WGS-20 20mm Diameter P10131
WGS-30 30mm Diameter P10132
WGS-35 35mm Diameter P10111
WGS-70 70mm Diameter P10112
WGS-105 105mm Diameter P10113
WGS-140 140mm Diameter P10114
WGS-210 210mm Diameter P10115
WN Series Earth Leakage Transformers (supports RN Relay)
WN series Leakage Transformers support the RN Relays covering diameters from 20mmup to 210mm.
WN Series E1
Type Description Item No.
WNS-20 20mm Diameter P10221
WNS-30 30mm Diameter P10222
WN-35 35mm Diameter P10211
WN-70 70mm Diameter P10212
WN-105 105mm Diameter P10213
WN-140 140mm Diameter P10214
WN-210 210mm Diameter P10215
RS-485Ethernet
CVM NRG 96 RGU-10 C TCP2RS
Avoid Unplanned Trips
Metering Devices - Eaton
Power Xpert Meters
The Power Xpert 4000 Meter
provides core functions for
monitoring power consumption &power quality. This unit uses Delta
Sigma technology to sample
circuits at 1024 samples
per cycle for extremely accurate
measurement of harmonics & other events.
The Power Xpert 6000 Meter adds another level of sampling ability,
using a combination of voltage & duration to isolate sub-cycle
oscillatory transients. An optional 512MB memory card provides
generous storage for waveforms & other event data.
The Power Xpert 8000 Meter adds the ability to capture very fast
transients by sampling at 6 MHz - 100,000 samples per cycle. Thats
a sample every 166 nanoseconds-six samples every millionth of a
second, across three input channels & neutral-to-ground.
Power Xpert Meter 4000/6000/8000 POA
Type Item No.
PowerXpert 4000 Meter, No Options PX4051A1AA
PowerXpert 4000 Meter with 512MB
CompactFlash Card
PX6051A5AA
PowerXpert 6000 Meter, No Options PX6051A1AA
PowerXpert 6000 Meter with 512MB
CompactFlash Card
PX6051A5AA
PowerXpert 8000 Meter, No Options PX8051A1AA
PowerXpert 8000 Meter with 512MB
CompactFlash Card
PX8051A5AA
PowerXpert Meter Graphic Display Module PXD-MMG
PowerXpert Bracket for Back-to-Back
Mounting
PX-PMBA
PowerXpert Communication
Expansion Card
PXCE-B
PowerXpert I/O Card PXIO-B
Metering
Metering
8/11/2019 NZ Products Guide Power Management
16/21390
Power Management
EATON CORPORATION New Zealand Product Guide
Metering Devices - Eaton
Power Xpert Meter 2000 series
Compact Power Quality Metering productsThe meters combine state-of-the-art technologywith waveform viewing, data trending &
performance benchmarking. The embedded Webserver enables users to surf to the meter over theInternet via a standard Web browser. This platformoffers adaptability such as field-upgradeablefirmware & optional digital inputs/outputs& analogue outputs.
Identify power quality problemsto help:
Protect motors from damage
Preserve the integrity of processes & batches
Prevent blown capacitor bank fuses
Protect transformers & conductors from overheating
The Power Xpert Meter 2250This meter provides all the core functions for monitoring power consumption & powerquality along with 256MB for data logging, Ethernet connectivity & onboard gatewaycard limits. This unit uses D/A technology to sample circuits at 400 samples per cyclefor accurate measurement of power factor & energy consumption.
The Power Xpert Meter 2260This meter adds the ability to monitor total harmonic distortion & the ability to set onboardmeter limits. The meter also will illuminate LEDs on the faceplate, indicating that a limit hasbeen exceeded. This meter comes standard with 512MB for data logging.
The Power Xpert Meter 2270This meter adds the ability to monitor individual harmonics & visualize waveforms on yourdesktop using the embedded Web server. This meter comes with 768MB for data logging.
Power Xpert Meter 2250/2260/2270 POA
Type Item No.
PXM2250 Meter/Display 50Hz 5A 90-265V AC/DC PXM2250MA55105
PXM2260 Meter/Display 50Hz 5A 90-265V AC/DC PXM2260MA55105
PXM2270 Meter/Display 50Hz 5A 90-265V AC/DC PXM2270MA55105
IQ 250/260 series
The IQ 250 & IQ 260 electronic meters provide capabilities you wouldnt normally expectin an affordable, compact metersuch as fast sampling rate & accurate metering for a fullrange of power attributes. The meter can be configured either from the easy-to-read displayor remotely (accessible via a Power Xpert Gateway) for upgrades to input/output optioncards.
Eatons IQ 250 & IQ 260 meters provide direct-reading metered values for the most criticalpower aspects, such as watts, watt demand,watt-hours, voltage-amperes (VA), VA-hours,vars, var-hours & power factor. They havehigh sampling speed & accuracy. The IQ 260meter also measures power quality, such as
total harmonic distortion (THD) up to the 40thorder. The IQ 260 also provides configurablelimit alarming/control capability of up to eightmeasured parameters for more sophisticatedpower management.
Features
Comprehensive metering
High-end accuracy
Self-test capability to validate
accuracy
Large, easy-to-read display
Local or remote configuration
Industry-standard communication protocols (Modbus)
Mix-and-match input/output options
Integration with Eatons Power Xpert Architecture
Field-upgradeable
IQ 100 series
Providing the first line of defense against
costly power problems, Eatons IQ 100
electronic power meters can perform the
work of an entire wall of legacy metering
equipment utilizing todays technology. Eatons
IQ 100 meters use 24-bit AD converters that
sample at more than 400 samples per cycle
& meet ANSI C12.20 standards for accuracy
of 0.5 percent. With such high-performance
measurement capability, these meters can be
confidently used for primary revenue metering
& sub-metering applications.
Eatons IQ 100 meters provide direct-reading
metered values for the most critical power
aspects, such as watts, watt demand, watt hours, voltage-amperes (VA), VA-hours, vars,
var hours & power factor. They have high sampling speed & accuracy.
Applications
Utility & commercial metering
Substations, industrial facilities, power generation sites & campuses
Sub-metering
Load studies & voltage recording
Analogue meter replacement
IQ Energy Sentinels
IQ Sentinels are highly accurate, microprocessor-based sub-meters, designed to monitorpower, energy, currents, voltages, power factor, frequency, apparent power & reactivepower. IQ Sentinels provide a unique cost effective method to implement energysub metering at lower levels in the electrical distribution systems.
IQ Energy Sentinels - MCCB Mounted Device POA
Type Model No.
F - Frame MCCB Voltage rating 240/415 Volts
150 Amps
IQESF400
J - Frame MCCB Voltage rating 240/415 Volts
250 Amps
IQESJ400
K - Frame MCCB Voltage rating 240/415 Volts
250 Amps
IQESK400
IQ Power Sentinels - Universal Device (Stand Alone) POA
Type Model No.
Universal with Internal CTs, Voltage rating 240 / 415 Volts 400 Amps IQESUI400
Universal with External CTs, Voltage rating 240 / 415 Volts 400 Amps IQESUE400
Universal with Internal CTs, Voltage rating 240 / 415 Volts 400 Amps IQPSUI400
Metering
Metering
8/11/2019 NZ Products Guide Power Management
17/21391
Power Management
EATON CORPORATION New Zealand Product Guide
Power Factor Correction Components
PowerFactor
CorrectionComponents
Power Factor Correction Components
8d & 14d Power Factor Regulators
8d & 14d Power Factor Regulators are based on a microprocessor that monitors thepower system status. This provides the ability to calculate whether to connect or disconnectcapacitors in achieving the target power factor setting.
Capacitor Step regulation is determined by selecting a 8d model which has the capabilityto control eight steps & similarly 14d type is capable to switch 14 steps. LED Indicationlights provide local status of power factor & connected capacitors.
Capacitors & Reactors Components for local OEMs to design & manufacturecapacitor banks.
Power Factor Regulators E1
Type Size (mm) Model No. Item No.
6 Step PFC Regulator (Basic) 144 x 144 Computer MAX 6 R10831
12 Step PFC Regulator (Basic) 144 x 144 Computer MAX 12 R10842
8 Step PFC Regulator 144 x 144 Computer 8d-8-144a R10125
14 Step PFC Regulator 144 x 144 Computer 14d-12-144a R10213
Communications Card for 14d - RS485 R18011
6 Step PFC Regulator Static Switching
(Thyristors)
144 x 144 Computer MAXf 6 R10851
12 Step PFC Regulator Static Switching
(Thyristors)
144 x 144 Computer MAXf 12 R10862
Cylindrical Type LV Capacitors E1
Type Size Model No. Item No.
CLZ-FP 52/12.5kVAr Capacitor 12.5kVAr at 525V CLZ-FP - 52/12.5 R2055D
CLZ-FP 52/20kVAr Capacitor 20kVAr at 525V CLZ-FP - 52/20 R2055F
CLZ-FP 52/25kVAr Capacitor 25KVAr at 525V CLZ-FP - 52/25 R2055G
Reactive Filters for PFC - FR Series E1
Type I(n) Losses (Watts) Model No. Item No.
Reactor for 12.5kVAr Capacitor 18 53 RX-12.5-415 P71013
Reactor for 25kVAr Capacitor 37 92 RX-25-415 P71016
Reactor for 50kVAr Capacitor 75 187 RX-50-415 P71019
Power Factor Accessories E1
Type Capacitor Max. Power kVAr Model No. Item No.
Fast Discharge Resistors 2 x (1500 Ohms/20 Watts) 1-25 RD-25 R3Z210
Fast Discharge Resistors 2 x (1000 Ohms/20 Watts) 25-60 RD-60 R3Z220
Impedance Limiting Coil for Wire CSA of 6mm2 - IR-6 R3Z310
Impedance Limiting Coil for Wire CSA of 10mm2 - IR-10 R3Z320
Impedance Limiting Coil for Wire CSA of 25mm2 - IR-25 R3Z330
Impedance Limiting Coil for Wire CSA of 35mm2 - IR-35 R3Z340
8d-8-96a 6m CLZ-FP
8/11/2019 NZ Products Guide Power Management
18/21392 EATON CORPORATION New Zealand Product Guide
Power ManagementSolar Power Solutions
SolarPowerSolutions
The amount of solar energy reaching the earths surface is vast. So vast, in fact,
that the earth receives twice as much energy from the sun as it does from all
non-renewable resources (coal, oil, natural gas, uranium) combined.
Renewable energy
8/11/2019 NZ Products Guide Power Management
19/21393
Power Management
EATON CORPORATION New Zealand Product Guide
Solar Power Solutions
SolarPowerSolutions
DC switching & protection
Eaton offers a comprehensive range of solutions forprotecting & switching the DC current generated byPV panels. Our solutions are designed & tested tomeet local standards applicable to solar electricalBOS equipment.
AC switching & protection (LV)
Eaton is a global leader in AC switching & protectionsolutions. From solar inverter to utility grid connection,we can help keep AC current flowing safely, reliablyand efficiently. Many of our solutions can be customisedto meet your specific requirements.
AC switching & protection (MV)
Eaton can provide customised solutions that meetthe demands for sustainability in electrical distribution.Eatons Xiria ring main units & SVS modular switchgearprovide environmentally friendly solutions for the safeand reliable distribution of energy.
AC/DC Surge protection
In microseconds a power surge can do majordamage to sensitive electrical equipment. Thatswhy we build so much quality into our full rangeof AC & DC surge protection products. Eaton
has a world beating reputation for power qualityand surge protection solutions coveringevery eventuality.
Load centres & enclosures
Eaton provides a range of low voltage assembliesand enclosures, from compact Load Centres toIP44 & IP66 rated distribution boards, as wellas blank equipment panels or Puggle boxes.The assemblies are suited for both Quicklagand DIN Miniature Circuit Breaker types &can be custom designed to suit customerspecified distribution, controls and/ormonitoring applications.
Monitoring & metering
Monitoring energy use carefully can help
you optimise energy efficiency. Eaton offersa wide range of sophisticated metering &monitoring solutions that help track &communicate the state of your solarpower system.
Vacuum contactors
Eaton is a global leader in low voltage switchgear.Our vacuum contactors can safely switch AC voltagesup to 1500V. Vacuum chambers limit arcing &protect the main contacts debris. These heavyduty contactors can perform millions of operationsin even the harshest environments.
Customised kits
Eaton has the capability of supplying solarproducts in kit form which simplifies theordering, logistics & installation processes.For more information on our custom kits,
contact Eaton.
Solar Power Solutions
Domestic, commercial & industrial
Electrical Balance of systemWhen it comes to electrical Balance Of System (BOS) for renewable energy installations,
you need a supplier you can trust & rely on. Eaton has been in the electrical power systembusiness for over a century & has a global reputation for excellence.
Single source convenienceWe offer the convenience of one stop shopping for electrical BOS solutions. Our solutionsare designed to work as a compatible, reliable system. You will have a single BOS supplier,a single purchase order & the confidence that comes from working with a leadingglobal supplier.
Solutions customised for your needsWe can design & produce electrical BOS t ailored to your unique requirements forresidential, commercial & industrial applications.
Inverter OEM & ODM capabilityOur customers have the option & flexibility of either custom branding or designing PV solar
inverters to their required specifications. Eaton has the resources & engineering expertiseto guide you through the OEM & ODM processes.
8/11/2019 NZ Products Guide Power Management
20/21394
Power Management
EATON CORPORATION New Zealand Product Guide
Solar Power Solutions
SolarPowerSolutions
Solar Power Solutions
Domestic, commercial & industrial
Other renewable energy products are available on request.
Solar Products
Description Item No.
20A 2 pole 500V DC rated 6kA MCB PLS6-C20/2-DC-AU
20A 1 pole 250V AC rated 6kA MCB PLS6-C20/1-AU
20A 2 pole 900VDC Circuit Breaker PKZ-SOL20
4 pole IP65 loadcentre FKV-O7-FR65-1/4
6 pole IP55 loadcentre PE6ST-IP55
2 pole MCB cover PE2E
1 pole MCB cover PE1E
Single pole surge diverter DIN SPDV60-300
20mm Nylon Glands FBAG20
1kW Grid Connect Solar Inverter ETN1000
2kW Grid Connect Solar Inverter ETN2000
Inverter Enclosure IP66 TBA
For our full product range refer pages 21 & 22. Discount code M01.
For our full product range refer page 38. Discount code M00.
For our full product range refer page 450. Discount code E6.
For our full product range refer page 412. Discount code B23.
8/11/2019 NZ Products Guide Power Management
21/21
Eaton: Your single source for Solar
Electrical Balance Of System solutions
When it comes to solar electrical Balance Of System
(BOS) for renewable energy solutions, you need a
supplier you can trust and rely on. Eaton has been
in the electrical power system business for over a
century and has a global reputation for excellence.
Eaton offers a comprehensive range of products to
compliment our high conversion efciency PV grid
connect inverters.
Our range includes:
PV Grid Connect Inverters
AC/DC switching and protection AC/DC Surge protection
Load centres and enclosures
System monitoring and metering
Vacuum contactors
Customised kits
For further Information:
0508 328 6669
Photovoltaic Grid