4
PST Page 1 8/26/2022 This is the simple example template containing only headers for each report item and the bookmarks. The invisible bookmarks are indicated by text between brackets. Modify it according to your own needs and standards. Measurement Conditions: Dataset Name NP File name C:\Documents and Settings\Calcutta University\Desktop\ NEW TEST\NILKAMAL PRAMANIK 02.09.2014\ NP\NP.xrdml Comment Configuration=PW3071/xx Bracket, Owner=User-1, Creation date=7/20/2006 9:22:09 AM Goniometer=PW3050/60 (Theta/Theta); Minimum step size 2Theta:0.001; Minimum step size Omega:0.001 Sample stage=PW3071/xx Bracket Diffractometer system=XPERT-PRO Measurement program=SUJAY X-CELERATOR, Owner=User-1, Creation date=9/8/2011 4:26:27 PM POWDER & SHIT Measurement Date / Time 9/2/2014 12:28:19 PM Operator Sujay Debnath Department Polymer Science & Technology Organization Calcutta University Raw Data Origin XRD measurement (*.XRDML) Scan Axis Gonio Start Position [°2Th.] 5.0367 End Position [°2Th.] 59.9817 Step Size [°2Th.] 0.0330 Scan Step Time [s] 19.4369 Scan Type Continuous PSD Mode Scanning PSD Length [°2Th.] 2.12 Offset [°2Th.] 0.0000 Divergence Slit Type Fixed Divergence Slit Size [°] 0.9570 Specimen Length [mm] 10.00

NP REPORT

Embed Size (px)

DESCRIPTION

np

Citation preview

This is the simple example template containing only headers for each report item and the bookmarks

PSTPage 29/2/2014

This is the simple example template containing only headers for each report item and the bookmarks. The invisible bookmarks are indicated by text between brackets.

Modify it according to your own needs and standards.

Measurement Conditions:

Dataset NameNP

File nameC:\Documents and Settings\Calcutta University\Desktop\

NEW TEST\NILKAMAL PRAMANIK 02.09.2014\

NP\NP.xrdml

CommentConfiguration=PW3071/xx Bracket, Owner=User-1, Creation

date=7/20/2006 9:22:09 AM

Goniometer=PW3050/60 (Theta/Theta); Minimum step size

2Theta:0.001; Minimum step size Omega:0.001

Sample stage=PW3071/xx Bracket

Diffractometer system=XPERT-PRO

Measurement program=SUJAY X-CELERATOR,

Owner=User-1, Creation date=9/8/2011 4:26:27 PM

POWDER & SHIT

Measurement Date / Time9/2/2014 12:28:19 PM

OperatorSujay Debnath

Department Polymer Science & Technology

OrganizationCalcutta University

Raw Data OriginXRD measurement (*.XRDML)

Scan AxisGonio

Start Position [2Th.]5.0367

End Position [2Th.]59.9817

Step Size [2Th.]0.0330

Scan Step Time [s]19.4369

Scan TypeContinuous

PSD ModeScanning

PSD Length [2Th.]2.12

Offset [2Th.]0.0000

Divergence Slit TypeFixed

Divergence Slit Size []0.9570

Specimen Length [mm]10.00

Measurement Temperature [C]25.00

Anode MaterialCu

K-Alpha1 []1.54060

K-Alpha2 []1.54443

K-Beta []1.39225

K-A2 / K-A1 Ratio0.50000

Generator Settings30 mA, 40 kV

Diffractometer Type0000000011014322

Diffractometer Number0

Goniometer Radius [mm]240.00

Dist. Focus-Diverg. Slit [mm]91.00

Incident Beam MonochromatorNo

SpinningNo

Main Graphics, Analyze View: NP

Peak List:

Pos. [2Th.]Height [cts]FWHM [2Th.]d-spacing []Rel. Int. [%]

26.7538247.031.10883.32950100.00

44.075720.230.09002.054638.19

Document History:

Insert Measurement:

- File name = "NP.xrdml"

- Modification time = "9/2/2014 12:36:11 PM"

- Modification editor = "Calcutta University"

Default properties:

- Measurement step axis = "None"

- Internal wavelengths used from anode material: Copper (Cu)

- Original K-Alpha1 wavelength = "1.54060"

- Used K-Alpha1 wavelength = "1.54060"

- Original K-Alpha2 wavelength = "1.54443"

- Used K-Alpha2 wavelength = "1.54443"

- Original K-Beta wavelength = "1.39225"

- Used K-Beta wavelength = "1.39225"

- Incident beam monochromator = "No"

- Dist. focus to div. slit = "91.00000"

- Irradiated length = "10.00000"

- Spinner used = "No"

- Receiving slit size = "0.10000"

- Step axis value = "0.00000"

- Offset = "0.00000"

- Sample length = "10.00000"

- Modification time = "9/2/2014 12:36:11 PM"

- Modification editor = "Calcutta University"

Interpolate Step Size:

- Step Size = "Derived"

- Modification time = "2/1/2006"

- Modification editor = "PANalytical"

Search Peaks:

- Minimum significance = "4.00"

- Minimum tip width = "0.01"

- Maximum tip width = "2.00"

- Peak base width = "10.00"

- Method = "Top of smoothed peak"

- Modification time = "5/20/2014 6:53:57 PM"

- Modification editor = "Calcutta University"