field electric room notes

Citation preview

****make below mentioned changes before starting work on Real Project/Field Auxiliary Room***Beacuse of unavailaity of Design Basis and other design related documents below mention things are done roughly or base on the assumptions.1- wind load wind velocity is assumed 55 m/secthe method of wind load application is wrong it should be tributary area based, now it s applied roughly on some column joints by sacs default method 2- Now column joint fixity as based is considered as fixied, it should be as per the connection details.3- live load is assumed 3kn/m2 at base level and 1 kn/m2 t roof, it sholud be as per design basis .4- some of the member properties are not correctly given in sacs because of the limitiation of sacs , some of the sectionsare not available in sacs like (unsymetrical double anlgle) 5- For blast analysis DAF is taken as 1.5 as no dyanamc analysis is performed . as per FABIG.