12
Ammonia Industrial Applications 1-16 Tons NH 3 Dual Discharge Evaporator MDAN > > USED FOR SMALL TO MEDIUM INDUSTRIAL AMMONIA APPLICATIONS – MANUFACTURED WITH STAINLESS STEEL TUBES.

NH Dual Discharge Evaporator 3 MDAN - guntner.us · resistant galvanized steel. All casings are powder coated - color rAl ... Aluminum fins with a corrugated ... All fins are manufactured

  • Upload
    lybao

  • View
    220

  • Download
    0

Embed Size (px)

Citation preview

Ammonia Industrial Applications 1-16 Tons

NH3 Dual Discharge Evaporator

MDAN> > U s e D f o r s M A l l T o M e D I U M I N D U s T r I A l A M M o N I A A p p l I c AT I o N s – M A N U f A c T U r e D w I T h s TA I N l e s s s T e e l T U b e s .

…keep(s) your quality. www.guntnerus.com

…keep(s) your quality

09.09

with seven decades of experience and commitment to total client

satisfaction, Guntner has earned a reputation as the global leader in heat

exchange technology. supported by the best r&D engineers in the business,

cutting-edge technology, and eight manufacturing facilities around the

world, Guntner continues to break new ground in the demanding market

of finned heat exchangers for industrial refrigeration, hVAc, and process

cooling applications. our high standards and dedication to society and the

environment around us have earned us the respect of the industry, and the

privilege of long-term relationships with our customers around the world.

The Global LeaderIn Heat Exchange Technology

www.guntnerus.com …keep(s) your quality. 109.09

Mpc

Guntner ProductCalculator

Guntner ProductCalculator

MPC_Label_2007.qxd 21.11.2006 14:53 Uhr Seite 1

> > c A l c U l AT I o N s M A D e e A s y w I T h o U r p r e c I s e M p c s o f T w A r e

with the Guntner product calculator “Mpc,” we are able to offer you

more than just an overview of prices or the complete product range.

This thermodynamic selection program enables you to calculate your

own tailored selections based on precise and actual thermodynamics

rather than factors or multipliers. A team of experts stand by to guide

you through the selection process.

The program can be updated via the internet ensuring that you always

have the most exact and precise information for proper selection.

we recommend using Guntner’s product calculator for exact

thermodynamic calculations. Varying conditions such as refrigerants,

humidity levels and material combinations are all taken into account by

the software to most accurately select products to fit your specific needs.

The Guntner Product Calculator

…keep(s) your quality. www.guntnerus.com2 09.09

Casing: The casing is corrosion resistant Aluminum (AIMg3) and seawater resistant up to fan diameter 20” (500 mm). from fan diameter 26” (650 mm) and larger, the casing is treated and painted corrosion resistant galvanized steel.

All casings are powder coated - color rAl 9003 (signal white) and suitable for all stringent food industry applications.

construction detail takes accessibility into account and does not allow for “tight spots.” All parts are easily accessible for service and cleaning purposes.

fan orifices are optimized by the manufacturer to ensure maximum efficiency, air throw and airflow. All fans are individually compartmented within complete tube sheets.

All hangers and fittings used for construction and assembly are manufactured from stainless steel 304. products have easily removable side panels for access to internal and electrical components.

Tray: All models have corrosion resistant light weight Aluminum (AlMg3) and are seawater resistant.

Trays are powder coated color rAl 9003 (signal white). All trays are our unique “fold down” type and can be either folded down or completely removed, if required, for for cleaning purposes. The “sloped design” of the tray ensures maximum and efficient drainage during defrost cycle. Drain outlet connection can be either 2 x 1 1/4” NpT or 2 x 3/4” NpT.

Standard Features of Construction

www.guntnerus.com …keep(s) your quality. 309.09 3

Tube: All tubing, headers and connections are manufactured from the highest quality 304 stainless steel 5/8” (15mm) tubing.

parallel, “in-line,” 1.969” x 1.969” (50 x 50mm) allows the reduced air-side pressure to drop through the coil. Tubes are mechanically expanded to ensure mechanical bonding coupled with the best heat transfer efficiency ratio from fin to tube.

our proven “floating coil” with support tubes does not permit the refrigerant carrying tubes to come into contact with the tube/end plates, and eliminates the risk of tube failure at the tube end plates. All coils are pressure tested to 450 psig with dry air under water, and shipped with a holding charge.

Fins: Aluminum fins with a corrugated pattern provide enhanced air turbulence, guaranteeing contact with all surface areas within the coil bundle. 100% drawn die formed finned collars are standard and result in accurate fin spacings of 6.3, 3.6 and 2.5 fpI (4, 7 and 10 mm).

All fins are manufactured with a continuous fin sheet in order to reduce the risk of frost build up, air-side pressure drops, dust, dirt and bacteria - simplifying any cleaning procedure.

Coil CirCuiTing: each unit is specifically circuited to optimize coil performance and capacity with a low pressure drop (consult with selection software to obtain best circuiting for each application). horizontal headers are standard for re-circulated and flooded applications. coil connections are manufactured from 304 stainless steel in accordance with AsMe b31.5 requirements.

Fans & MoTors: external rotor axial fans are standard for the entire range.

Internal motor thermo contacts must be incorporated into the control circuit for motor protection.

All motors are aluminum die cast and of the highest efficiency. They are also maintenance free with guaranteed long life and low noise levels.

fan guards are galvanized steel and pVc coated. All motors are of the blow through type.

standard voltages are 230V and 460V for 3~ / 60hz applications and 400V for 3~ / 50hz applications.

DeFrosT: standard defrost options for all units include air, electric or hot gas.

electric heater elements are stainless steel sheathed and fit directly into tubes within the coil bundle to provide enhanced heat transfer during the defrost cycle.

elements are held in place with clips to prevent them from moving during transport or operation.

eleCTriCal: All fan motors are factory wired to the junction box with single point connection. however, factory installed jumpers can be removed for individual / capacity control. All heater wiring is terminated within a junction box for quick and simple field connections. when heater circuit amperages exceed 48 amps, multiple circuits are provided in order to comply with the Nec limitation of 48 amps per circuit.

Delivery & PaCking: All units are crated and shipped in a position to help facilitate installation.

…keep(s) your quality. www.guntnerus.com4 09.09

ConsTruCTion MaTerials

• The entire casing unit, tube sheets and tray manufactured with either 304 or 316 stainless steel.

• Insulated pan (required by the USDA for certain food / processing applications).

• Insulated fan panel.

• Epoxy coated aluminum or stainless steel (304 or 316) fins.

• Units are supplied standard with carbon steel black pipe connections but can be ordered with either stainless steel pipe, flanges (ANsI b16.5) or carbon steel threaded connection (AsMe b1.20).

• Re-heat coils – separated from the cooling coil by means of an air gap.

• Foot mounts for floor mounting.

• For unit operation below -40ºF – consult sales office.

Fans anD MoTors

• Oversize motors for higher face velocities and / or external pressures.

• Two speed, high efficiency or explosion proof motors.

• Draw through option on some models (down blow).

Optional Features

DeFrosT oPTions

• The use of fan ring heaters is recommended for low temperature applications available in 230 and 460V).

• For electric defrost - defrost termination and fan delay thermostat factory fitted.

• Heater limit thermostat fitted and pre-wired.

• Factory installed check valve between tray and coil for hot gas defrost.

eleCTriCal

• No wiring.

• All motors wired to common / individual non-fused disconnect.

• All motors wired to common fused disconnect with thermal protection for each motor.

• All motors wired to fused disconnect with single starter and thermal protection for each motor.

• Various wiring options are available – please consult with factory for an alternative to suit your specific requirements.

www.guntnerus.com …keep(s) your quality. 509.09

MDan 051 C/ 1 7 -a l

ProDuCT line

Fan DiaMeTer 16” 041 18” 046 20” 051 26” 066

volTage X 1/230/60 J 3/400/60 l 3/460/60 s 3/400/50 U 3/230/60

DeFrosT A AIr e elecTrIc h hoT GAs

Fin sPaCing 4 4mm - 6.3 ppI 7 7mm - 3.6 ppI 10 10mm - 2.5 ppI

rows DeeP c/

no. oF Fans 1

evaporator MDan

UNIT MODEL

FaN

FaN MOTOrS- ELECTrICaL SPECIFICaTIONS

Fan Diameter Motor ratings @3Ph/60Hz (ea.) soundPower level guntner

mm inch voltage HP rpm Fla db (a) spare Part no.

041… 400 16460 1/4 1490 0.58 73.0

VT0354U230 1/4 1400 0.9 72.0

046… 450 18460 1/4 1390 0.62 73.0

VT01174U230 1/4 1270 1.1 70.5

051… 500 20460 1/2 1350 0.96 75.5

VT01176U230 1/3 1210 1.65 73.0

066… 650 26460 1/2 860 1.25 77.0

VT01178U230 1/2 790 2.2 74.8

…keep(s) your quality. www.guntnerus.com6 09.09

Performance Data: all Models

MODEL NO. MDaN

COIL

wet Frosted surface area Tube volume Fin spacing

btu/hr/°F TD btu/hr/°F TD ft2 ft3 fpi

1 fAN

041a/14- 1,732 1,219 372 0.24

6.3046a/14- 2,474 1,664 497 0.29

051C/14- 4,891 3,190 931 0.53

066C/14- 7,356 5,541 1490 0.82

041C/17- 1,817 1,386 329 0.35

3.6

046C/17- 2,323 1,908 439 0.44

051C/17- 3,123 2,350 548 0.53

066C/17- 4,681 3,852 877 0.82

066D/17- 6,665 4,997 1169 1.10

041C/110- 1,483 1,222 237 0.35

2.5

046C/110- 2,005 1,555 316 0.44

051C/110- 2,549 2,122 395 0.53

066C/110- 4,027 3,157 631 0.82

066D/110- 5,440 4,526 842 1.10

2 fAN

041a/24- 3,468 2,444 745 0.41

6.3046a/24- 4,956 3,333 993 0.53

051C/24- 9,447 6,989 1862 0.97

066C/24- 15,148 11,100 2979 1.53

041C/27- 3,638 2,779 658 0.62

3.6

046C/27- 4,905 3,818 877 0.79

051C/27- 6,249 4,970 1096 0.97

066C/27- 9,873 7,971 1754 1.53

066D/27- 13,339 10,001 2339 2.04

041C/210- 2,969 2,449 474 0.62

2.5

046C/210- 4,014 3,114 631 0.79

051C/210- 5,099 4,249 789 0.97

066C/210- 8,041 6,724 1263 1.53

066D/210- 10,878 9,059 1684 2.04

3 fAN

041a/34- 5,225 3,847 1117 0.59

6.3046a/34- 7,087 5,403 1490 0.77

051C/34- 14,714 9,584 2793 1.41

066C/34- 22,074 17,237 4469 2.24

041C/37- 5,220 4,282 987 0.88

3.6

046C/37- 7,472 5,727 1316 1.15

051C/37- 9,377 7,058 1645 1.41

066C/37- 15,038 11,558 2631 2.24

066D/37- 20,918 15,482 3508 2.98

041C/310- 4,462 3,488 710 0.88

046C/310- 6,104 4,893 947 1.15

051C/310- 7,870 6,374 1184 1.41 2.5

066C/310- 12,252 10,122 1894 2.24

066D/310- 16,372 12,745 2526 2.98

* Units with heater amp draws greater than 48 amps will be supplied with multiple circuits- as required by the Nec

www.guntnerus.com …keep(s) your quality. 709.09

MODEL NO. MDaN

aIr FLOw ELECTrIC DEFrOSTsound

Pressure level

air Throwsound

Pressure level

Total Coil Tray amp Draws

@ 3/460/60 @ 3/230/60 @3/460 @3/230

cfm fpm cfm fpm ft db (a) kw w w a a

1 fAN

041a/14- 1,913 496 1,795 466 2x20 58 3.4 1,800 1600 4.3 8.5

046a/14- 2,737 532 2,531 493 2x26 58 5 3,000 2000 6.3 12.6

051C/14- 3,502 545 3,178 495 2x33 60 6.2 3,800 2400 7.8 15.6

066C/14- 5,150 501 4,738 462 2x36 61 9.8 6,600 3200 12.3 24.6

041C/17- 1,825 473 1,677 436 2x20 58 4 2,400 1600 5.0 10.0

046C/17- 2,649 515 2,472 481 2x26 58 5 3,000 2000 6.3 12.6

051C/17- 3,649 568 3,296 513 2x33 60 6.2 3,800 2400 7.8 15.6

066C/17- 5,415 527 4,974 484 2x39 61 9.8 6,600 3200 12.3 24.6

066D/17- 4,974 484 4,561 444 2x36 61 12 8,800 3200 15.1 30.1

041C/110- 1,854 481 1,707 443 2x20 58 4 2,400 1600 5.0 10.0

046C/110- 2,678 521 2,501 487 2x26 58 5 3,000 2000 6.3 12.6

051C/110- 3,649 568 3,325 518 2x33 60 6.2 3,800 2400 7.8 15.6

066C/110- 5,533 538 5,062 493 2x39 61 9.8 6,600 3200 12.3 24.6

066D/110- 5,062 492 4,650 453 2x33 61 12 8,800 3200 15.1 30.1

2 fAN

041a/24- 3,826 497 3,590 466 2x26 61 5.9 3,300 2600 7.4 14.8

046a/24- 5,474 533 5,062 492 2x36 60 9.2 6,000 3200 11.5 23.1

051C/24- 7,004 545 6,357 495 2x46 63 11.4 7,200 4200 14.3 28.6

066C/24- 10,300 501 9,476 461 2x49 63 18.4 13,200 5200 23.1 46.2

041C/27- 3,649 474 3,355 435 2x26 61 7 4,400 2600 8.8 17.6

046C/27- 5,297 516 4,944 481 2x36 60 9.2 6,000 3200 11.5 23.1

051C/27- 7,298 568 6,592 513 2x46 63 11.4 7,200 4200 14.3 28.6

066C/27- 10,830 527 9,947 484 2x52 63 18.4 13,200 5200 23.1 46.2

066D/27- 9,947 484 9,123 444 2x49 63 22.8 17,600 5200 28.6 57.2

041C/210- 3,708 481 3,414 443 2x29 61 7 4,400 2600 8.8 17.6

046C/210- 5,356 521 5,003 487 2x39 60 9.2 6,000 3200 11.5 23.1

051C/210- 7,298 568 6,651 518 2x46 63 11.4 7,200 4200 14.3 28.6

066C/210- 11,065 538 10,124 493 2x52 63 18.4 13,200 5200 23.1 46.2

066D/210- 10,124 493 9,300 453 2x52 63 22.8 17,600 5200 28.6 57.2

3 fAN

041a/34- 5,739 496 9,150 466 2x33 62 8.9 5,100 3800 11.2 22.3

046a/34- 8,211 533 12,900 492 2x42 62 13.6 8,800 4800 17.1 34.1

051C/34- 10,506 545 16,200 495 2x56 64 17 10,800 6200 21.3 42.7

066C/34- 15,450 501 24,150 462 2x59 64 26.8 19,200 7600 33.6 67.3

041C/37- 5,474 473 8,550 435 2x33 62 10.6 6,800 3800 13.3 26.6

046C/37- 7,946 515 12,600 481 2x46 62 13.6 8,800 4800 17.1 34.1

051C/37- 10,948 568 16,800 513 2x56 64 17 10,800 6200 21.3 42.7

066C/37- 16,245 527 25,350 484 2x65 64 26.8 19,200 7600 33.6 67.3

066D/37- 14,921 484 23,250 444 2x62 64 33.2 25,600 7600 41.7 83.3

041C/310- 5,562 481 8,700 443 2x36 62 10.6 6,800 3800 13.3 26.6

046C/310- 8,034 521 12,750 487 2x46 62 13.6 8,800 4800 17.1 34.1

051C/310- 10,948 568 16,950 518 2x56 64 17 10,800 6200 21.3 42.7

066C/310- 16,598 538 25,800 493 2x65 64 26.8 19,200 7600 33.6 67.3

066D/310- 15,185 492 23,700 453 2x62 64 33.2 25,600 7600 41.7 83.3

* Units with heater amp draws greater than 48 amps will be supplied with multiple circuits- as required by the Nec

…keep(s) your quality. www.guntnerus.com8 09.09

Dimensions: all Models

MODEL NO.

MDaN

UNIT DIMENSIONS CONNECTIONS*with water Defrost option add 4 inches to “H”. refrigerant Hot gas Drain net weight

linch

binch

H*inch

einch

Finch

innPs

outnPs

innPs nPT lb

1 fAN

041a/14- 39 3/8 61 5/8 17 11/16 23 5/8 59 7/16 1/4 1/4 1/2 3/4 146

046a/14- 47 1/4 61 5/8 17 11/16 31 1/2 59 7/16 1/4 1/4 1/2 3/4 171

051C/14- 55 1/8 61 5/8 17 11/16 39 3/8 59 7/16 3/4 3/4 1/2 3/4 227

066C/14- 72 7/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 437

041C/17- 39 3/8 61 5/8 17 11/16 23 5/8 59 7/16 1/4 1/4 1/2 3/4 149

046C/17- 47 1/4 61 5/8 17 11/16 31 1/2 59 7/16 1/4 1/4 1/2 3/4 175

051C/17- 55 1/8 61 5/8 17 11/16 39 3/8 59 7/16 3/4 3/4 1/2 3/4 197

066C/17- 72 7/8 76 5/8 20 47 1/4 74 1/2 3/4 3/4 1/2 1 1/4 392

066D/17- 72 7/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 431

041C/110- 39 3/8 61 5/8 17 11/16 23 5/8 59 7/16 1/4 1/4 1/2 3/4 149

046C/110- 47 1/4 61 5/8 17 11/16 31 1/2 59 7/16 1/4 1/4 1/2 3/4 174

051C/110- 55 1/8 61 5/8 17 11/16 39 3/8 59 7/16 3/4 3/4 1/2 3/4 196

066C/110- 72 7/8 76 5/8 20 47 1/4 74 1/2 3/4 3/4 1/2 1 1/4 391

066D/110- 72 7/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 427

2 fAN

041a/24- 63 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 240

046a/24- 78 3/4 61 5/8 17 11/16 31 1/2 59 7/16 3/4 3/4 1/2 3/4 291

051C/24- 97 5/8 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 3/4 417

066C/24- 120 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 748

041C/27- 63 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 249

046C/27- 78 3/4 61 5/8 17 11/16 31 1/2 59 7/16 3/4 3/4 1/2 3/4 303

051C/27- 97 5/8 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 3/4 355

066C/27- 120 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 648

066D/27- 120 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 735

041C/210- 63 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 249

046C/210- 78 3/4 61 5/8 17 11/16 31 1/2 59 7/16 3/4 3/4 1/2 3/4 302

051C/210- 97 5/8 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 3/4 354

066C/210- 120 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 646

066D/210- 120 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 732

DrawINGS FOr aLL MODELS

www.guntnerus.com …keep(s) your quality. 909.09

DrawINGS FOr aLL MODELS

MODEL NO.

MDaN

UNIT DIMENSIONS CONNECTIONS*with water Defrost option add 4 inches to “H”. refrigerant Hot gas Drain net weight

linch

binch

H*inch

einch

Finch

innPs

outnPs

innPs nPT lb

3 fAN

041a/34- 89 3/4 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 345

046a/34- 113 1/2 61 5/8 17 11/16 31 1/2 59 7/16 1 1 1/4 1/2 1 1/4 428

051C/34- 143 3/4 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 1 1/4 602

066C/34- 167 3/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 1074

041C/37- 89 3/4 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 351

046C/37- 113 1/2 61 5/8 17 11/16 31 1/2 59 7/16 1 1 1/4 1/2 1 1/4 435

051C/37- 143 3/4 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 1 1/4 513

066C/37- 167 3/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 920

066D/37- 167 3/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 1044

041C/310- 89 3/4 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 350

046C/310- 113 1/2 61 5/8 17 11/16 31 1/2 59 7/16 1 1 1/4 1/2 1 1/4 434

051C/310- 143 3/4 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 1 1/4 511

066C/310- 167 3/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 912

066D/310- 167 3/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 1047

www.guntnerus.com

…keep(s) your quality.