12
300100115869 Rev A © 2016. CommScope. All Rights Reserved. Table of Contents Recommended Patch Cord Length (Meters/Feet)................ General Routing Guidelines ............................................ Cross-Connect Within Single Frame ................................ Cross-Connect Between Frames ..................................... Installing Adapter Packs on Front of Universal Chassis........ Routing Patch Cord Within Universal Chassis..................... Interconnect Application Without FOTSP ........................... Interconnect Application With FOTSP ................................ 1 2 5 6 8 10 11 12 25221-A NG4access ODF Platform Patch Cord Routing Guide TECP-90-705 • Issue 4• 3/2016

NG4access ODF Platform - CommScope...2017/12/20  · Page 2 General Routing Guidelines TECP-90-705 • Issue 4 • 3/2016 25029-B A B *Fiber Optic Storage Panel Recommended Patch Cord

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • 300100115869 Rev A © 2016. CommScope. All Rights Reserved.

    Table of ContentsRecommended Patch Cord Length (Meters/Feet)................ General Routing Guidelines ............................................ Cross-Connect Within Single Frame ................................ Cross-Connect Between Frames .....................................Installing Adapter Packs on Front of Universal Chassis........ Routing Patch Cord Within Universal Chassis.....................Interconnect Application Without FOTSP........................... Interconnect Application With FOTSP................................

    1 2 5 6 8 10 11 12

    25221-A

    NG4access ODF PlatformPatch Cord Routing Guide

    TECP-90-705 • Issue 4• 3/2016

  • Page 2 www.commscope.com

    General Routing Guidelines

    TECP-90-705 • Issue 4 • 3/2016

    25029-B

    A

    B

    *Fiber Optic Storage Panel

    Recommended Patch Cord Length (Meters/Feet)Number of Frames

    1 2 3 4-5 6 7-8 9 10-11 12-13

    WithoutFOTSP*

    6 m 7 8 9 9 11 13 14 15

    20 ft 22.5 25 30 30 35 42 45 50

    WithFOTSP*

    6 m 8 9 11 12 14 15 17 19

    20 ft 25 30 35 40 45 50 55 60

    1. Always route patch cords down from chassis termination point (A) or front-to-rear trough (B).

  • 25220-A

    www.commscope.com Page 3

    2. Always store slack on last end to be terminated and terminate both ends before storing slack. To do this: Terminate patch cord at origination chassis (A). Terminate patch cord at destination chassis (B). Route both ends to bottom trough (C). Pull slack to anchor spools (D). Move slack loop up and over storage spools, placing loop on top of highest spool (E), leaving a gentle drip loop below the anchor spool (D).

    TECP-90-705 • Issue 2 • 3/2016

    A

    B

    D C

    E

  • FRONTROUTING

    REARROUTING

    REARHORIZONTAL

    TROUGH

    FRONT-TO-REARTROUGH

    NOTE:TOP OF FRAME, TOP OF CHASSIS,AND RIGHT SIDE SHEET METALNOT SHOWN FOR CLARITY.

    25222-A

    Page 4 www.commscope.com

    TECP-90-705 • Issue 4 • 4/2016

    A

    3. Always route from origination frame (A) to destination frame using front-to-rear trough (B) and rear horizontal trough (C). To route to a termination point on same frame, use vertical cable guides (D) front routing.

    C

    B

    D

    FRONTROUTING

    REARROUTING

    REARHORIZONTALTROUGH

    FRONT-TO-REARTROUGH

    NOTE:TOP OF FRAME, TOP OF CHASSIS,AND RIGHT SIDE SHEET METALNOT SHOWN FOR CLARITY.

    25222-A

  • www.commscope.com Page 5

    TECP-90-705 • Issue 4 • 3/2016

    4. Never wrap a patch cord around the same spool mutiple times or in a figure eight pattern.

    5. Never route patch cords up from a chassis or front-to-rear trough toward the top of the frame.

    24954-B

    25039-B

  • 25084-B

    D

    C

    A

    B

    E

    Page 6 www.commscope.com

    Cross-Connect Within a Single FrameConnect patch cord at first termination point (A). Connect at second termination point (B). Route down through vertical cable guides to bottom trough (C). Route to anchor spools (D). Loop over highest storage spool highest spool (E), leaving gentle drip loop.

    TECP-90-705 • Issue 4 • 3/2016

    Termination points on opposite sides of frame

    Termination points on same side of frame

  • 25028-B

    REARHORI-

    ZONTALTROUGH

    ENTER ON LEFT TOTERMINATE ON RIGHT

    ENTER ON RIGHT TOTERMINATE ON LEFT

    www.commscope.com Page 7

    TECP-90-705 • Issue 4 • 4/2016

    Cross-Connect Between Frames Determine proper patch cord length from table on page 2. Terminate origination end of patch cord (A). Route through front-to-rear trough (B) to rear horizontal trough (C) to destination frame front-to-rear trough (D) (always on opposite side of frame from termination point). Route down through vertical cable guides to bottom trough (E). Connect other end of patch cord (F). Route to anchor spools (G). Take up slack on storage spools (H), looping the slack over the highest spool leaving gentle drip loop below anchor spool.

    Destination Frame Origination Frame

    C A

    E

    D

    G

    FH

    B

  • 2519

    5-A

    F

    A B D E I J K L

    H

    C

    AC

    CE

    SS

    TR

    AY

    HA

    ND

    LE

    AC

    CE

    SS

    TR

    AY

    SL

    OT

    (3X

    )

    TE

    CP

    -90-

    705

    • Is

    sue

    4 •

    3/20

    16

    Flip these pages clockwise to view them horizontally.In

    stal

    ling

    Ad

    apte

    r P

    acks

    Ada

    pter

    pac

    ks c

    an b

    e in

    -st

    alle

    d fr

    om e

    ither

    fro

    nt

    or r

    ear

    of t

    he c

    hass

    is.

    If

    inst

    allin

    g fr

    om t

    he fro

    nt:

    Pull

    open

    cha

    ssis

    doo

    r (n

    ot s

    how

    n) a

    nd le

    t it

    swin

    g do

    wn

    belo

    w t

    he

    chas

    sis.

    Pul

    l out

    the

    acce

    ss t

    ray

    hand

    le (

    A)

    to a

    cces

    s th

    e tr

    ay.

    Posi

    tion

    the

    adap

    ter

    pack

    ta

    bs o

    n th

    e ac

    cess

    tra

    y sl

    ots

    in lo

    catio

    ns (

    B),

    (C

    ), a

    nd D

    ).Pr

    ess

    the

    tabs

    into

    the

    slo

    ts u

    ntil

    a de

    finite

    clic

    k is

    hea

    rd

    or f

    elt.

    Pus

    h in

    acc

    ess

    tray

    han

    dle

    to c

    lose

    the

    ac

    cess

    tra

    y.

    Page

    8

    A

    CB

    D

    NO

    TE

    : Orien

    t ad

    apte

    r pa

    cks

    with

    TE

    logo

    fac

    ing

    to f

    ront

    .

  • TE

    CP

    -90-

    705

    • Is

    sue

    4 •

    3/20

    16

    Flip these pages clockwise to view them horizontally.R

    ou

    tin

    g P

    atch

    Co

    rd

    Wit

    hin

    Un

    iver

    sal

    Ch

    assi

    s (s

    ho

    wn

    on

    left

    si

    de

    acce

    ss t

    ray)

    Pu

    ll op

    en c

    hass

    is d

    oor

    (not

    sho

    wn)

    and

    let

    it sw

    ing

    dow

    n be

    low

    the

    ch

    assi

    s.

    Pull

    out

    acce

    ss t

    ray

    hand

    le (

    A)

    to a

    cces

    s ad

    apte

    rs.

    Con

    nect

    pat

    ch c

    ord

    to

    desi

    gnat

    ed a

    dapt

    er (

    B).

    Plac

    e pa

    tch

    cord

    with

    in

    tray

    cab

    le g

    uide

    (C).

    Plac

    e pa

    tch

    cord

    aro

    und

    end

    of a

    rm g

    uide

    (D

    ).

    Rout

    e pa

    tch

    cord

    to

    oute

    r si

    de g

    uide

    st

    rip

    (E).

    Pus

    h in

    acc

    ess

    tray

    han

    dle

    to c

    lose

    ac

    cess

    tra

    y (A

    ).

    Page

    9

    A

    BE

    C

    D

    (con

    tinue

    d on

    nex

    t pa

    ge)

    2495

    0-A

  • FR

    ON

    TR

    OU

    TIN

    G

    RE

    AR

    RO

    UT

    ING

    RE

    AR

    HO

    RIZ

    ON

    TAL

    TR

    OU

    GH

    FR

    ON

    T-TO

    -RE

    AR

    TR

    OU

    GH

    NO

    TE

    :TO

    P O

    F F

    RA

    ME

    , TO

    P O

    F C

    HA

    SS

    IS,

    AN

    D R

    IGH

    T S

    IDE

    SH

    EE

    T M

    ETA

    LN

    OT

    SH

    OW

    N F

    OR

    CL

    AR

    ITY.

    2494

    9-A

    ww

    w.c

    omm

    scop

    e.co

    m

    Pag

    e 10

    Rout

    e pa

    tch

    cord

    do

    wn

    guid

    e to

    tr

    ough

    “de

    cisi

    on

    poin

    t” (

    F),

    and

    then

    in e

    ither

    of

    two

    dire

    ctio

    ns:

    thro

    ugh

    fron

    t-to

    -re

    ar t

    roug

    h (G

    ) to

    rea

    r ho

    rizo

    ntal

    tr

    ough

    (H

    ), t

    hen

    to d

    estin

    atio

    n fr

    ame;

    or

    dow

    n th

    roug

    h ve

    rtic

    al c

    able

    gu

    ides

    on

    sam

    e fr

    ame

    (I).

    Clo

    se

    chas

    sis

    door

    (no

    t sh

    own)

    . N

    OTE

    : Th

    is d

    raw

    ing

    also

    sh

    ows

    the

    sam

    e ro

    utin

    g st

    eps

    for

    rout

    ing

    a pa

    tch

    cord

    on

    a righ

    t si

    de a

    ccce

    ss t

    ray.

    FG

    I

    H

    (con

    tinue

    d fr

    om p

    revi

    ous

    page

    )

  • 25034-B

    FIBERGUIDE SYSTEM

    www.commscope.com Page 11

    TECP-90-705 • Issue 3 •3/2016

    Interconnect Routing on Single Frame(Without FOTSP)

    Route patch cord downfront of frame from above (A) (always on opposite side of frame from termination point).

    Connect patch cord at designated chassis adapter (B).

    Route patch cord through vertical cable guides and bottom trough (C) to anchor spools (D).

    Store slack on storage spools (E), looping the slack over the highest spool, leaving gentle drip loop below anchor spools.

    A

    B

    CD

    E

  • FIBERGUIDE SYSTEM

    25194-A

    Page 12 www.commscope.com

    TECP-90-705 • Issue 4• 4/2016

    Interconnect Routing on Single Frame(With FOTSP)

    Route patch cord from FiberGuide System down through FOTSP front trough (A).

    Connect patch cord at designated chassis adapter (B).

    Route patch cord through vertical cable guides to bottom trough (C)and then to anchor spools (D).

    Store slack on storage spools (E), looping the slack over the highest spool, leaving gen-tle drip loop below anchor spools.