New technology for fire security when working with electrical equipment According to statistic, every fifth fire starts because of electrical wiring and electrical equipment problems. CJC «PiroChimica» www.pirohim.ru

New technology for fire security when working with electrical equipment

  • Upload
    tripan

  • View
    15

  • Download
    5

Embed Size (px)

DESCRIPTION

FIRE SAFETY FROM RUSSIA.

Citation preview

Page 1: New technology for fire security when working with electrical equipment

New technology for fire security when working with electrical equipment

According to statistic, every fifth fire starts because of electrical wiring and electrical equipment problems.

CJC «PiroChimica»www.pirohim.ru

Page 2: New technology for fire security when working with electrical equipment

2

Under ordinary conditions, the agent is securely stored in capsules. Being completely isolated of environment , it emanates no vapor or gases. Can be stored for years, remaining fully operational and ready for fire extinguishing.

AST protection technology: autonomous microencapsulated outgassing thermal activated fire extinguishing system

Upon heating, the micro-capsules response to ignition on their own and release desired amount of the fire retardant instantly quenching the flame.

In the process of extinguishing, the hotbed of fire is the only place subjected to action of the agent while surrounding structures and objects remain unaffected.

Page 3: New technology for fire security when working with electrical equipment

3

AST uses a combination of chladones as an extinguishing agent. The extinguishing agent is stored inside capsules in a liquid state. When the temperature rises to a predetermined threshold, the liquid boils and quenching occurs in the gas phase.

AST protection technology: autonomous microencapsulated outgassing thermal activated fire extinguishing system

This principle is classified as a volumetric gas quenching.

Extinguishing mechanism is based on the chemical inhibition of the combustion reaction. When injected into the combustion zone inhibitor decomposes with the formation of free radicals, which react with the primary products of combustion. Thus, the combustion reaction inhibited.

Page 4: New technology for fire security when working with electrical equipment

4

AST protection technology: autonomous microencapsulated outgassing thermal activated fire extinguishing systemObject of protection: electrical panelReason of protection: heated ET

Page 5: New technology for fire security when working with electrical equipment

5

Certified product line:

AST 15, 25, 45, 60, 105, 140, 180 –

Certified product line for protecting different volumes.

АСТ Р – protection of sockets or other micro-volumes.

autonomous extinguishing systems PiroChimica

AST

Page 6: New technology for fire security when working with electrical equipment

6

PC case short circuit:

Page 7: New technology for fire security when working with electrical equipment

7

Socket short circuit:

Page 8: New technology for fire security when working with electrical equipment

8

Server rack protection: AST protection technology

Page 9: New technology for fire security when working with electrical equipment

9

Technology modification

AST P - thermal-activated outgassing extinguishing coating

Designed for preventing fires in:• Cable structures (channels)• Raised floors• Plenums, and other local volumes• Tanks and containers for storing and

transporting flammable products.

autonomous extinguishing systems PiroChimica

AST

Page 10: New technology for fire security when working with electrical equipment

10

Cable channel ignitionTechology of protection: AST coating – 2011 perspective product

Page 11: New technology for fire security when working with electrical equipment

11

Raised floor ignitionTechology of protection: AST coating – 2011 perspective product

Page 12: New technology for fire security when working with electrical equipment

12

COOPERATION

The technology is developed in cooperation with Research Institute of Fire Protection of EMERCOM of RussiaThe AST product line was fullytested and certified.

Technology was awarded with a Gold Medal of a Day of advanced

technologies and innovations of Russian Emergencies Ministry

autonomous extinguishing systems PiroChimica

AST

Page 13: New technology for fire security when working with electrical equipment

13

AST products implementation and operation:

• Russian Interior Ministry troops• The Federal Security Service• Russian Railways• NPP "Stalenergo“• Demonstration Area in Krasnoyarsk, objects of F1.1 • Moscow Metro (trains and fixed electric assemblies)• AST Products found to be effective for dangerous and technically

complex and unique capital construction projects in Moscow and entered into the register of town planning.

Page 14: New technology for fire security when working with electrical equipment

14

Regulatory changes:

According to the SP 5.13130.2009 considering changes № 1, enacted by Order of MES of Russia 01.06.2011 № 274

Switchboards and cabinets (including distributional ones), located in the premises of a F1.1 fire hazard class (equivalent to 100 liters) MUST be protected autonomous fire extinguishing (p.8 Table A4)F1.1 fire hazard class includes: buildings preschool educational institutions, specialized nursing homes (non apartment type), hospitals, dormitories educational residential care and childcare.

Page 15: New technology for fire security when working with electrical equipment

15

Regulatory changes:

According to the SP 5.13130.2009 considering changes № 1, enacted by Order of MES of Russia 01.06.2011 № 274

Premises for computing machinery, equipment control system working in the management of complex technological processes, the violation of which affects the safety of the people regardless of the area, MUST be equipped with automatic fire extinguishing systems, but if all electronic and electrical equipment is protected by autonomous fire-fighting installations, such extinguishing systems may not be installed. As premises for the communication processors (servers), magnetic media archives, plotters, printing information on paper (printer) area of 24 m2 or more, must be equipped with automatic fire extinguishing. And it is allowed not to use such facilities, provided that all electronic and electrical equipment is protected by autonomous fire-fighting installations. (Paragraph 35 Table A3).Thus, the operator of the premises has a choice between automatic gas fire extinguishing systems for protection of facilities and stand-alone equipment to protect electrical equipment.

Page 16: New technology for fire security when working with electrical equipment

PiroChimica

Resort 01 Made in Russia