19
New stent technology Magnesium-alloy The Progress-AMS Study Raimund Erbel, M Haude, Th Konorza, D Boese Department of Cardiology West-German Heart Center Essen University Duisburg-Essen www.wdhz.de [email protected] Erbel et al., Lancet 2007;369(9576):1869

New Stent Technology: Magnesium-alloy

Embed Size (px)

Citation preview

Page 1: New Stent Technology: Magnesium-alloy

New stent technologyMagnesium-alloy

The Progress-AMS StudyRaimund Erbel,

M Haude, Th Konorza, D BoeseDepartment of Cardiology

West-German Heart Center EssenUniversity Duisburg-Essen

[email protected]

Erbel et al., Lancet 2007;369(9576):1869-75

Page 2: New Stent Technology: Magnesium-alloy

• Purpose• To evaluate the clinical feasibility of an

absorbable metal stent in the treatment of a single de novo lesion in a native coronary artery

• Design• Prospective, multi-center, consecutive, non-

randomized FIM (First In Man – coronary) study

MACE rate after 4 months <30 % comparable to BMS • Hypotheses

Clinical Performance and Angiographic Results of the Coronary Stenting with Absorbable Metal Stents The PROGRESS-AMS Study

Erbel et al., Lancet 2007;369(9576):1869-75

Page 3: New Stent Technology: Magnesium-alloy

PROGRESS STUDYPrincipal Investigator Raimund Erbel, MD, Essen, Germany

Co-Chairman Ron Waksman, MD, Washington, USA

Raimund Erbel, MD, Essen, GermanySteering Committee Ron Waksman, MD, Washington, USA

Bernd Heublein † , MD, Hannover, Germany

CEC & DSMB Jan Bart Hak, PhD, Groningen, NL Martial Hamon, MD, Caen, France Rafael Beyar, MD, Haifa, IsraelIVUS Core laboratory Neil J. Weissman, MD, Washington, USA

QCA Core laboratory Cardialysis, Rotterdam, The Netherlands

Data Coordinating Ron Waksman, MD, Washington, USA

Study Coordination Stefan Wagner, PhD, Erlangen, Germany

Erbel et al., Lancet 2007;369(9576):1869-75

Page 4: New Stent Technology: Magnesium-alloy

PROGRESS STUDY

Australia M Horrigan, Melbourne, AUS

Belgium B de Bruyne & W Wijns, Aalst, BE

Germany M Haude, S Sack, D Boese, R Erbel, DE

Netherlands JJRM Bonnier & J Koolen, Eindhoven

Switzerland F Eberli & T Lüscher, Zurich, CH P Erne, Luzern, CH

UK C Di Mario & C Ilsley, London, UK

USA R Waksman, Washington, USA

Erbel et al., Lancet 2007;369(9576):1869-75

Page 5: New Stent Technology: Magnesium-alloy

• 2.5 mm x 15 mm pre PTCA• < 16 atm AMS implantation 3.0 mm 3.5 mm• AMS size 10 mm 15 mm• < 16 atm post dilatation if necessary• double marker balloon• angiogram/IVUS before and after implantation

PROGRESS STUDYProcedure Details

Erbel et al., Lancet 2007;369(9576):1869-75

Page 6: New Stent Technology: Magnesium-alloy

PROGRESS Study Protocol

Screening

Treat-ment

1 dpost

1 m post ± 7 d

4 m post ± 1 w

6 m post ± 2 w

12 m post± 4 w

Clinical follow-up X X X X X X

CK (CK-MB)/ Troponin I X X

QCA X X

IVUS X X

MRI (subgr.)* X X X

*MRI for analysis of degradation kinetics Erbel et al., Lancet 2007;369(9576):1869-75

Page 7: New Stent Technology: Magnesium-alloy

PCI Procedure Characteristics n- pre dilatation 100 % 63/63• pressure (8 atm, 20 sec) 9 ± 2.1- AMS pressure, atm 16 ± 0.9- post dilatation 67 % 42/63- post dilatation pressure, atm 16 ± 3.9- 2nd stent - average stent number

13 % 1.1 ± 0.3

8/63

PROGRESS STUDY

Erbel et al., Lancet 2007;369(9576):1869-75

Page 8: New Stent Technology: Magnesium-alloy

PROGRESS Study

0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0

100

80

60

40

20

0

MLD [mm]

MLD:1,05 ± 0,38

MLD stent:2,47 ± 0,37

Gain:1,41 ± 0,46

Cum

ultiv

e di

strib

utio

n %

Erbel et al., Lancet 2007;369(9576):1869-75

Page 9: New Stent Technology: Magnesium-alloy

Magnet Resonance Imaging of AMS The MRI compatible Stent

Magnetom, (Sonata, 1.5 T, Siemens)

Eggebrecht et al Circulation 112, 303 – 4, 2005

• optimal vessel imaging• no stent artefacts,• AMS not visible

Page 10: New Stent Technology: Magnesium-alloy

Computed Tomography 16 MSCT: AMS Stent

A B

C D

Lind et al Heart 91:1604, 2005

bms- stent

AMS Stent

AMS StentBMS Stent

Page 11: New Stent Technology: Magnesium-alloy

Mg-Stent bare metal stent

1 mm

Micro CT of AMS and BMS

Malyar et al 2006

Page 12: New Stent Technology: Magnesium-alloy

After AMS Stent implantation

after 18 days

Acute result

Erbel et al JACC 2005

GIRO 065-001 C-R

Page 13: New Stent Technology: Magnesium-alloy

Absorbable Metal Stent (AMS)

0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0

100

80

60

40

20

0

MLD [mm]

MLDstent:2,47 ± 0,37

MLDf/u:1,34 ± 0,49

Loss:1,08 ± 0,49

cum

ulat

ive

dist

ribut

ion

%

Erbel et al., Lancet 2007;369(9576):1869-75

Page 14: New Stent Technology: Magnesium-alloy

QCA AnalysisParameter before after 4 - Months

Ref MLD/mm 2.76 2.67 ± 0.47 ± 0.46MLD/mm 1.05 2.47 1.34 ± 0.38 ± 0.37 ± 0.49Acute gain/mm 1.41 ± 0.46

Late loss/mm 1.08 ± 0.49D % Stenosis 62 13 48 ± 13 ± 6 ± 17

Erbel et al., Lancet 2007;369(9576):1869-75

Page 15: New Stent Technology: Magnesium-alloy

Time of TLR

0

20

40

60

80

100

0 30 60 90 120 150 180 210 240 270 300 330 360

days after intervention

TLR

eve

nts

PROGRESS STUDY

4 Months Angiography

Erbel et al., Lancet 2007;369(9576):1869-75

Page 16: New Stent Technology: Magnesium-alloy

% N % N % N

MACE Mortality 0 0 0 0 0 0

Q- MI (Q- mit CK or CK-MB)

0 0 0 0 0 0

Non Q - MI (CK 2 x UNL)

0 0 0 0 0 0

Ischemia driven TLR

0 0 0 0 23.8 15

Hospital 30-days 4-Months

PROGRESS STUDY

Erbel et al., Lancet 2007;369(9576):1869-75

Page 17: New Stent Technology: Magnesium-alloy

17

Stenosis diameteer (%) 39.1

Stenosis area ( %) 62.9

MLD (mm) 1.67

MLA (mm²) 2.19

Reference diameter (mm) 2.74

Reference area (mm²) 5.90

Vessel segment length(mm) 27.1

Stenosis length (mm) 13.5

Baseline values

Vasomotion Testing after Magnesium Stent

Erbel et al., Lancet 2007;369(9576):1869-75

Page 18: New Stent Technology: Magnesium-alloy

Stenosis diameter (%) 56.4

Stenosis area (%) 81.0

MLD (mm) 1.16

MLA (mm²) 1.06

Reference diameter (mm) 2.67

Reference area (mm²) 5.59

Vessel segment length (mm) 25.3

Stenosis length (mm) 17.9

Acetylcholine testing

Vasomotion Testing after Magnesium Stent

Erbel et al., Lancet 2007;369(9576):1869-75

Page 19: New Stent Technology: Magnesium-alloy

Magnesium Stent

Conclusion • AMS realized with low recoil• High technical sucess• AMS permits MRT and CT based imaging• No acute or subacute stent thrombosis• iTLR rate comparable to BMS• IVUS detected degradation within 4 M• Vasomotion reactivation Drug elution and AMS delayed degradation – Dream concept*

* Please listen to R Waksman in the next session, room 6