Distributed by:
Head Office3F., ANTEX24, 1-1-14, Taito,Taito-ku, Tokyo, 110-0016 Japan
03(5818)5130 03(5818)5131 E-mail [email protected]
Sales Department 03(5818)5130 03(5818)5131
Overseas Depa rtment 03(5818)5134 03(5818)5131
E-mail [email protected]
Nagoya Office1F., EIKEI Bldg., 1-307, Yashirogaoka, Meitou-ku, Nagoya-shi,Aichi, 465-0051 Japan
052(701)1227 052(701)1250
Osaka Office7F., NITTETSU SUMIKIN KOSAN KUJO Bldg., 1-27-6, Kujo, Nishi-ku,Osaka-shi, Osaka, 550-0027 Japan
06(6584)3185 06(6584)3160
Fukuoka Office6F., HAKATA Sun City Bldg. Ⅱ, 3-11-28,Hakataeki-Higashi, Hakata-ku,Fukuoka-shi, Fukuoka, 812-0013 Japan
092(433)0250 092(433)0251
Tsukuba Factory6127-5, Onogo-machi, Jos o-shi,Ibaraki, 300-2521 Japan
0297(24)1071 0297(24)1075
Service Center6127-5, Onogo-machi, Joso-shi,Ibaraki, 300-2521 Japan
0297(24)1071 0297(24)1075
Worchemi Taiwan Co., Ltd.No.13, Lane 513, Shenlin South Rd.,Daya District, Taichung City 428, 42859 Taiwan R.O.C.
886-4-2560-9315 886-4-2560-9056URL http://ww w.worldchemical.com.twE-mail [email protected]
World Chemical USA, Inc.30 Hughes, Suite 203, Irvine, CA 92618, U.S.A
1-949-462-0900 1-949-462-0999URL http://ww w.worldchemicalusa.comE-mail [email protected]
Suzhou World Technology Co.,Ltd.402, Fu Yuan Road, Xiang Cheng, Economic District., Su Zhou, China
86-512-6579-8212 86-512-6579-8215URL http://ww w.worldchemical.com.cnE-mail [email protected]
http://www.wcc.co.jp/
Tsukuba Factory
New release
Super MAGSuper MAGBIG SIZE VALVELESS SELF-PRIMINGMAGNETIC PUMP
YD-8005GV SeriesYD-10007GV SeriesYD-10010GV Series
32
Internationally Patented Valveless Mechanism Internationally patented
AirAir Air
Air
Air
Air
Air
Liquid Air
Stop (Siphon break)
When the pump is shut down, the unique siphon break intercepts backflow by quicklyreleasing air so that priming water remains in the auxiliary tank. So pouring priming water into the tank is not necessary after second time
Before operation During Self-priming
During Operation Stop (Backflow)
1 52
3 4Strong for dry running
High-speed self-priming performance *suction lift 3m 1minites 30 secondsHigh-speed self-priming performance *suction lift 3m 1minites 30 seconds
Strong for Slurry and sludge! (Impeller wear ring construction)Strong for Slurry and sludge!(Impeller wear ring construction)
Strong for dry running
Unique construction separate air and liquid effectively to reduce self-priming loss maximize pump performance.
Impeller wear ring prevent slurry invading into rear casing side to protect impeller from wearing out. Penetrative slurry size is only under 0.127mm!! *If you want to use the pump under slurry condition, please consult with us.
SiC material is used for frictional part.
Unique valveless mechanism (Internationally patented) keep priming water in the pump for redriving without check valve.
Achieve high performance Max total head 25m, Max flow rate 1300L/min *10010GV 60Hz
Back pull out structure makes maintenance safe and easy.Adapting High-efficiency motor. (IE2 class)Leak free magnetic drive construction.Strong for emptying operation.
VALVELESS SELF-PRIMING MAGNETIC PUMP is developed to meet contemporary customer needs!VALVELESS SELF-PRIMING MAGNETIC PUMP is developed to meet contemporary customer needs!
1971
20102012
Valveless self-priming pump
Big magnetic pump
Corrosion-resistance Valveless self-priming magnetic pump
54
YD-8005GV, YD-10007GV, YD-10010GV
YD 8005GV PP KP52Discharge Bore
80 : 80A100 : 100A
5: 50Hz6: 60Hz
1: 1.1*2: 1.2
*YD-10007GV 60Hz
KP: SiC / FEP+FKMKE: SiC / EPDM
05: 3.7kW07: 5.5kW10: 7.5kW
PP: Polypropylene
Motor Output Model Main Material Bushing/Gasket Material Frequency S.G.
■ Model Type
■ Specification
■ Outline Drawing
■ Performance curveE
J F
DL
AB
CM
G HH6-φN
IK
Motor bracket Outer magnet
Shaft
Gasket
Bushing
Casing
ImpellerRear casing
Rear casing support
Motor bracket Outer magnet
ShaftCasiRear casing support
Gasket
Bushing
ImpellerRear casing
Model
Name
Casing
Impeller
Bushing
Shaft
Gasket
PP + SUS cover
CFR-ETFE
SiC
SiC
FEP+FKM / EPDM(FKM gasket protected with FEP cupsule )
Rear casing support
Outer magnet
Motor bracket
Motor
Base
Ductile Cast Iron
Rear casing CFR-ETFE + Fiber Reinforced Vinyl Ester
Ductile Cast Iron + Magnet
Ductile Cast Iron
Aluminum Alloy etc
SS400
Material Name MaterialYD-8005GV 80A×80A 3.7 500 - 20 110
YD-10007GV100A×100A
5.5 800 - 14 800 - 12 (SG1.1) 176
YD-10010GV
* Impeller and rear casing are subject for export administration regulation.* Exporter should receive the permission by METI.* The contents given in this booklet might be changed with no prior notice due to product improvement.
Model
Unit ( mm )
YD-8005GV
YD-10007GV
YD-10010GV
7.5 1200 - 12 178
Bore( Suction×Discharge )
Motor Output( kW )
Standard Performance ( L/min - m ) Weight( kg )
Self-priming height limit( m )
4.0( clean water at 20̊C )
A B C D E F G H I J K L M N
348 89 437 180 32 57.5 320 320 715 400 440 760.5
907
945
9 φ15
380 102 482 211 31 212.5 310 310 850 460 500 9 φ15
50Hz 60Hz
*SUS cover is equiped for UV protection.
0 250
8005GV
8005GV10007GV
10010GV
10007GV
10010GV
500 750 1000 1250 1500
10
20
30
86420
S.G. 1.2
Discharge (L/min) Discharge (L/min)
* The performance data is based on clean water at 20˚C with flooded suction.
Total Head (m)
Total Head (m)
50Hz 60Hz
Motor O
utput (kW)
8005GV
8005GV10007GV
10010GV
10010GV
86420
Motor O
utput (kW)
S.G. 1.2
0 250 500 750 1000 1250 1500
10
20
30
10007GV(S.G.1.1)
76
YD-8005GV, YD-10007GV, YD-10010GV
Capable of running with long horizontal suction piping, up-and-down piping.Anti-earthquake and leakfree measure.● Tank drain is dispensable with transferring from the top of the tank.● Installing far from the tank.● Flexible usage with 4m self-priming ablility.● Wide alternative for installation.● For transferring foamy, heavy, and high specific gravity liquid.● Foot valve is dispensable.● Capable of running with long horizonal suction piping.
*If you want ot use under long suction piping or emptying situation, please consult with us once.
Empting transfer Pumping transfer
Transferring,empting from tank lorry /Right-angle expansion pipe
Self-priming from end-suction
■ Installation method■ Example of use
1) Suction piping
① Use a suction pipe with the same diameter as the suction inlet.② Set the length of the suction pipe within 1 m. With over 1 m suction piping, self-suction ability is decreased remarkably because of much air quantity in the suction pipe. This may cause pump failure.③ In order to prevent entering air to the suction pipe, submerge suction pipe below liquid level at least 500 mm.④ In the case that pump is installed lower than liquid level, set a gate valve on a suction pipe for routine maintenance.⑤ Avoid an air trap on the suction piping and provide a slight upward slope toward the pump.⑥ Set an Air-release pipe away from the suction as far as possible.⑦ Keep the minimum liquid level at a depth of more than double the suction pipe bore diameter from the tip of the suction pipe. If the liquid level is lower, air can enter the pump and cause dry running.⑧ Place a strainer at the inlet of the piping to prevent foreign matter from entering the suction pipe.Clean the strainer periodically to prevent clogging and minimize loss resistance.
① Using the same diameter pipe for inlet and outlet is recommended. When you use smaller pipe than discharge inlet, self-suction ability is decreased because of insufficient air exhaust during self-priming. Moreover, it causes increase of pipe loss. In the end, decrease of the flow rate would happen. ② Set a check valve to prevent “Water hammer.” When installing situation is like as below. The discharge pipe is long or the discharge head is more than 10 m. Actual head is higher than 9 m. Two or more pumps are used in parallel.③ Set a gate valve on a discharge pipe for routine maintenance.④ Set a pressure gauge to check a pump operation.
2) Discharge installation
Over 500mm
Over 2D
Strainer
Tank
Drain plug
Within 4m
Pipe support
Pipe support
Suction pipe
Expansion joint Priming plug
Pressure gauge
Air ven
Gate valve
Gate valveGate valve
Pipe support