146180 SVAB APL Connecting Card© SVAB Hydraulik AB 2012-08-24
Page 1(2)
Overview - 146180 SVAB APL Connecting Card
Name of out ports:
GND GND GNDS Out9
Out4B Out4A Out3B Out3A
Out2B Out2A Out1B Out1AName with APLX Wheel Steering: Out4B2 Out4A2 Out4B1 Out4A1
Name with APLX Track Steering: Out72 Out62 Out71 Out61
Connection to Quick Coupler Switch302141 Quick Coupler Switch Wire
*also called Tool Lock Switch
x
QuickCoupler
Grip/3rdFunction
Extra/4thFunction
RotatorTilt
1.) These out ports are deactivated with Out8.2.) These out ports activated with Out8.
Connection to the GP Controller. 147555 Connection card wire, GP 1.3 m
Usage:The connecting card is the link between the rotortilt’s trunk cable and the GP Controller. To con-nect the trunk cable see page 2
Note:If the control system is to be equipped with wheel or track steering, then connect the APL card to a APLX Connecting Card. Instructions for connecting to the GP Controller accompany the APLX Card.
146180 SVAB APL Connecting Card© SVAB Hydraulik AB 2012-08-24
Page 2(2)
GN
D
GN
D
GN
DS
Out
9
Out
4B/4
B2 /
72
Out
4A/4
A2 /
62
Out
3B/4
B1 /
71
Out
3A/4
A1 /
61
Out
2B
Out
2A
Out
1B
Out
1A
Engcon SS10 - - 11 8 1 - - 4 5 6 7 2 3
Engcon SS18 - 12 11 8 1 9 10 4 5 6 7 2 3
Indexator - green/yellow 11 10 9 - - 8 7 6 5 4 3
SMP - 47 1 10 11 - - 8 9 2 3 6 5
STEELWRIST SS10 12 11 8 1 9 10 4 5 6 7 2 3
Trunk Cable ConnectionThe table here shows how the trunk cable from the rotortilt is connected to the APL Card. The wire leads are numbered and connected differently depending on the rotortilt manufacture. The diagrams below show a variety of machine cable configurations.
Engcon SS18
12348 7 6 59101141 31 211516
12348 7 6 59101141 31 211516
x
SMP
12348 7 6 591011
R*
Engcon SS10
12348 7 6 5910
12348 7 6 59
1112
Indexator
12348 7 6 5910
1112(green/yellow)