Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Proposed MM U02
137805
Proposed EH U02
137433
2Z050-104
New BuildCovered CourtYard SectionC-C
5G312-030
101 102 103 104
9G321-021
Section RL-05
12
1G312-030
Sim
4G312-030
Sim45 m²
College Board Room CBR305
Occupancy:20
49 m²Admin, Repro, Secure & General Stores
208
Occupancy:8
87 m²ICT CAD Suite I5
103
Occupancy:24
53 m²CIR 23
218
Occupancy:N/A
41 m²CIR 13
142
Occupancy:N/A
7G312-030
Sim
1701
10
2873
10
1656
6432 (site dim to be confirmed)
14G321-021
Section RL-07
Proposed MM U02
137805
Proposed U03
141624
4Z050-104
New BuildCovered CourtYard SectionB-B
AA BB CC DD EE FF GG HH
Dimension to be check on site4422
2736
18 m²CIR 22
217
Occupancy:N/A
18 m²CIR 22
217
Occupancy:N/A
16 m²CIR 12
141
Occupancy:N/A
18 m²CIR 11
140
Occupancy:N/A
53 m²CIR 23
218
Occupancy:N/A
19 m²CIR 26
314
Occupancy:N/A
53 m²CIR 23
218
Occupancy:N/A
46 m²PA Office
219
Occupancy:4
H43/116Composite cladding
1G312-030
Sim
6G312-030
Sim
1700
11
2873
10
1656
3G312-030
Sim
1G312-030
Sim
2G312-030
Sim
internal drainage route to be confirmed
1701
10
2873
173
17946
4885 (site dim to be confirmed)
Proposed MM U02
137805
Proposed EH U02
137433
2
Z050-104
New BuildCovered CourtYard SectionC-C
101 102 103 104
6G312-010
Sim
12
53 m²CIR 23
218
Occupancy:N/A
41 m²CIR 13
142
Occupancy:N/A
500
1188
6500 (site dim to be confirmed)
WSS -Weaving Shed
South
Castleway House, 17 Preston New Road, Blackburn, BB2 1AU
T +44 (0) 1254 273000 F +44 (0) 1254 273559
Project
Client
Drawing
Scale @ A1 Drawn Checked Approved
Project No.
Drawing Identifier
Date
BS1192:2007 / Uniclass Compliant
project origin zone level file type role number revision
Purpose of Issue Status
This drawing is copyright and owned by Capita Symonds Ltd., and is for use on thissite only unless contractually stated otherwise.
DO NOT SCALE this drawing (printed or electronic versions). Contractors must checkall dimensions from site.
All other design team elements, where indicated, have been imported from theconsultant's drawings and reference should be made to the individual consultant'sdrawings for exact setting out, size and type of component.
Discrepancies and / or ambiguities within this drawing, between it and information givenelsewhere, must be reported immediately to the architect for clarification beforeproceeding.
All works are to be carried out in accordance with the latest British Standards andCodes of Practice unless specifically directed otherwise in the specification.
Responsibility for the reproduction of this drawing in paper form, or if issued inelectronic format, lies with the recipient to check that all information has beenreplicated in full and is correct when compared to the original paper or electronicimage. Graphical representations of equipment on this drawing have been co-ordinated, but are approximations only. Please refer to the Specifications and / orDetails for actual sizes and / or specific contractor construction information.
This original document is issued for the purpose indicated below and containsinformation of confidential nature. Further copies and circulation will be strictly inaccordance with the confidentiality agreement under the contract. This original must bedestroyed or returned to the contractor.
SAFETY, HEALTH AND ENVIRONMENTAL INFORMATION
Refer to the relevant Construction (Design and Management) documentation whereapplicable.
It is assumed that all works on this drawing will be carried out by a competentcontractor, working where appropriate to an approved method statement.
Location Key Plan (Not to Scale)
© Capita Symonds Ltd - File Name:
A1
Print D
ate
:
www.capitasymonds.co.uk Capita Symonds Ltd.
Rev Description / By / Chk'd / App'd Date
Registered office: 71 Victoria Street, Westminster, London, SW1H 0XA. Registered inEngland and Wales No. 2018542 Part of the Capita Group Plc. www.capita.co.uk
uniclass
C:\Revit Local Files\UTC Model - LOCAL - HT.rvt
As indicated
15/1
0/2
012 2
0:4
4:2
8
UTC - Weavers Triangle
New Build Covered Court YardSections A-A, B-B & C-C
HT NJ
CS/054482 07/25/12
UTC - CS - CY - ZZ - DSC - AR - Z050-104
HT
C2
Architecture
1 : 50
New Build Covered Court Yard Section A-A1
1 : 50
New Build Covered Court Yard Section C-C2
1 : 50
New Build Covered Court Yard Section B-B4
A A
B B
C
C
Issued for Construction 24/09/12C1
Amended for Construction 15/10/12C2