    IBMSystemNetworkingRackSwitchG8316 1

    IBM System Networking RackSwitch G8316IBM Redbooks Product Guide

    TheIBMSystemNetworkingRackSwitchG8316provideslowlatency,losslessperformance,andafeature-richdesignwithkeyvirtualizationfeatures,suchasConvergedEnhanceEthernet(CEE)/DataCenterBridging(DCB),highavailability,andenterpriseclassLayer2andLayer3functions.Inaddition,theG8316alsodeliversexcellentcostsavingsasyouconsideracquisitioncosts,energycosts,operationalexpense,andeaseofuseandmanagementfora40Gbclassswitch.TheIBMSystemNetworkingRackSwitchG8316issuitableforclientsusing10Gbor40Gbconnectivity(orboth).

    TheG8316Ethernetaggregationswitchenablescustomerstoownanend-to-endflat2-tiernetworkthatisbasedonindustrystandardsusingIBMswitchesandservers.Forexample,theG8316isanidealtiertwoswitchtousewhenconnectinganumberofRackSwitchG826440Gbuplinkportsattheaccesslayer.OtherclientsliketheG8316asaninvestmentprotectionswitch,astheycanuseitwiththeir10GbEthernetenvironmentstoday,butcanalsoleverageitinthefutureastheymoveto40GbEthernet.

    Withlatencybelow1microsecond,theG8316isanindustryleader.Thisandthe1.28TbpsthroughputmakestheG8316anidealofferingforlatency-sensitiveapplications,suchashigh-performancecomputing,financialapplications,hostingenvironments,andclouddesigns.Inaddition,IBMVMreadywithVirtualVisionenablesthenetworktobeVirtualMachine(VM)aware,andprovidesthecapabilitytohaveavirtualizationenvironmentthatissimpler,lessexpensive,andprovidesexceptionalperformance.Figure1showstheIBMSystemNetworkingRackSwitchG8316.

    Figure1.IBMSystemNetworkingRackSwitchG8316

    Did you know?HerearethekeyfeaturesoftheRackSwitchG8316:

    Supportsseveraltypesofconfigurations:10Gb,and40Gb,VirtualNIC,ConvergedEnhancedEthernet(CEE/DCB),andiSCSI.

    SupportsDataCenterBridging(DCB),whichistheIEEEsgroupofprotocolsthatprovidelossless

    EthernetandallowsforclientstoreducethecostsofimplementingeitherNASoriSCSIconvergenceandpriority-basedflowcontrol.

    UsesVMreadyon-switchsoftwarethathelpsreducethecomplexityofmanagingvirtualmachines(VMs)inthenetwork(thelicenseforthiscapabilitycomesstandardwiththepurchaseoftheswitchandispartoftheIBMNetworkingOperatingSystem).

    TheRackSwitchG8316isOpenFlowenabled.WithOpenFlow,youcaneasilycreateuser-controlledvirtualnetworks,optimizeperformancedynamically,andminimizecomplexitywhenyouusetheswitchusedwithIBMProgrammableNetworkController.

  • 8/13/2019 Networking RackSwitch G8316

    2/16

    IBMSystemNetworkingRackSwitchG8316 2

    TheRackSwitchG8316includesastandardIBM1-yearhardwarewarranty,withNextBusinessDay(NBD),9x5,CustomerReplaceableUnit(CRU)warrantyservice.IBMalsoincludeoneyearofsoftwareupgrades.IBMServicePacsolutionsareavailable(inselectcountries)forhardwarewarrantyupgradeoptions.

    Table1liststhepartnumbers(IBMSystemx)fororderingmodulesandadditionaloptionsforthem,includingServicePacsolutions.

    Table1.IBMSystemNetworkingpartnumbersandfeaturecodes(part1)

    Description System x part numbers IBM Power Systems MTM /FCIBMSystemNetworkingRackSwitchG8316(Rear-to-Front)

    8036-ARX(HVEC)/8036-HC2(XCC)

    1611-16E

    IBMSystemNetworkingRackSwitchG8316(Front-to-Rear)

    8036-AFX(HVEC)/8036-HC1(XCC)

    10 Gb options Break-out using40Gb port)1mIBMQSFP+DACBreakOutCable*

    49Y7886 EB24

    3mIBMQSFP+DACBreakOutCable*

    49Y7887 EB25

    5mIBMQSFP+DACBreakOutCable*

    49Y7888 EB26

    40 Gb optionsIBMQSFP+SR4Transceiver 49Y7884 EB27

    IBMQSFP+LR4Transceiver 00D6222

    1mIBMQSFP+-to-QSFP+Cable* 49Y7890 EB2B

    3mIBMQSFP+-to-QSFP+Cable* 49Y7891 EB2H

    5mIBMQSFP+-to-QSFP+Cable* 00D5810 ECBN

    7mIBMQSFP+-to-QSFP+Cable* 00D5813 ECBP

    10mIBMQSFP+MTPOpticalCable 90Y3519 EB2J

    30mIBMQSPF+MTPOpticalCable 90Y3521 EC2K

    *QSFP+DACBreakOutcablesandQSFP+toQSFP+cablesarenotsupportedforPowerSystems10GbNICs.Theyareusedforswitchtoswitchconnectivityonly.

  • 8/13/2019 Networking RackSwitch G8316

    3/16

    IBMSystemNetworkingRackSwitchG8316 3

    Table1.IBMSystemNetworkingpartnumbersandfeaturecodes(part2)

    Miscellaneous optionsIBMSystemNetworkingAdjustable19"4PostRailKit

    00D6185 EU27

    IBMSystemNetworkingRecessed

    19"4PostRailKit(NeXtScale)

    00CG089

    Hot-swappable,Rear-to-FrontFanAssemblySpare

    88Y6026

    Hot-swappable,Front-to-RearFanAssemblySpare

    49Y7939

    Hot-swappable,Rear-to-FrontPowerSupplySpare

    49Y7938

    Hot-swappable,Front-to-RearPowerSupplySpare

    49Y7937

    ConsoleCableKitSpare 90Y9462

    ServicePacs available in selectcountries) System x part numbers Power Systems MTM/FC3-yearon-siterepair24x7two-hourresponse

    67567P1

    3-yearon-siterepair24x7four-hourresponse

    67567P0

    3-yearon-siterepair9x5four-hourresponse

    67567NZ

    4-yearon-siterepair24x7two-hourresponse

    67567P5

    4-yearon-siterepair24x7four-hour

    response

    67567P4

    4-yearon-siterepair9x5four-hourresponse

    67567P3

    4-yearon-siterepair9x5nextbusinessday

    67567P2

    5-yearon-siterepair24x7two-hourresponse

    67567P9

    5-yearon-siterepair24x7four-hourresponse

    67567P8

    5-yearon-siterepair9x5four-hourresponse

    67567P7

    5-yearon-siterepair9x5nextbusinessday

    67567P6

  • 8/13/2019 Networking RackSwitch G8316

    4/16

    IBMSystemNetworkingRackSwitchG8316 4

    WiththeflexibilityofIBMRackSwitch,clientscantakeadvantageofthetechnologiesthattheyrequireformultipleenvironments:

    For10Gb,theycanuseDACbreak-outcables,whichconverts40Gbportsintofour10Gbportsandallowsconnectionfordistancesupto5m.

    For40Gblinks,theycanuseQSFPtransceiversandMTPcables.

    Figure2showsthecables.

    Figure2.Cables

    Themodulepartnumbersincludethefollowingitems:

    OneIBMSystemNetworkingRackSwitchG8316R/G8316FGenericRailMountKit(2-post)Mini-USBConsoleportforserialaccess

    Figure3showsa2-postRackMountKit.

    Figure3.2-postRackMountKit

  • 8/13/2019 Networking RackSwitch G8316

    5/16

    IBMSystemNetworkingRackSwitchG8316 5

    Makesurethatyouincludepowercordsinyourconfiguration.Table2liststheappropriatepowercord,dependingoncountryofpurchaseforSystemx,andTable3listslinecordsavailablethroughIBMPowerSystemsandIBMSystemStorageAASorderingsystems.

    Table2.PowercorddescriptionandIBMSystemxpartnumbers

    Description IBM part numberPowerCordEuropeACplug10A/250V;OPT 39Y7917

    PowerCordEurope(Denmark)ACplug10A/250V;OPT 39Y7918

    PowerCordEurope(Switzerland)ACplug10A/250V;OPT 39Y7919

    PowerCordEuropeAC(Israel)plug10A/250V;OPT 39Y7920

    PowerCordEurope(SouthAfrica)ACplug10A/250V;OPT 39Y7922

    PowerCordUKACplug13A/250V;OPT 39Y7923

    PowerCordAustraliaACplug10A/250V;OPT 39Y7924

    PowerCordKoreaACplug10A/250V;OPT 39Y7925

    PowerCordJapanACplug10A/125V;OPT 46M2593

    PowerCordIndiaACplug10A/250V;OPT 39Y7927

    PowerCordChinaACplug16A/250V;OPT 39Y7928

    PowerCordBrazilACplug16A/250V;OPT 39Y7929

    PowerCordUruguay/ArgentinaACplug16A/250V;OPT 39Y7930

    PowerCordUS/CanadaACplug10A/125V;OPT 46M2592

    4.3m,10A/100-250V,C13toIEC320-C14RackPowerCable 39Y7932

    1.5m,10A/100-250V,C13toIEC320-C14RackPowerCable 39Y7937

    2.8m,10A/100-250V,C13toIEC320-C20RackPowerCable 39Y7938

  • 8/13/2019 Networking RackSwitch G8316

    6/16

    IBMSystemNetworkingRackSwitchG8316 6

    Table3.PowercordsdescriptionandIBMPowerSystemandIBMSystemStorageFeatureCodes

    Description Feature CodePowerCord4.3m(14-ft),DrawertoWall/IBMPDU(250V/10A) 6458

    PowerCord4.3m(14-ft),DrawertoWall/OEMPDU(250V/15A)U.S. 6469

    PowerCord1.8m(6-ft),DrawertoWall(125V/15A) 6470

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU(125V/15A) 6471

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU(250V/16A) 6472

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU(250V/10A) 6473

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU,(250V/13A) 6474

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU,(250V/16A) 6475

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU,(250V/10A) 6476

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU,(250V/16A) 6477

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU,(125V/15Aor250V/10A) 6488

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU,(250V/10A) 6493

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU,(250V/10A) 6494

    PowerCord4.3m(14-ft),DrawertoWall/OEMPDU(125V/15A) 6660

    PowerCord2.8m(9.2-ft),DrawertoWall/IBMPDU,(250V/10A) 6665

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU,(250V/10A) 6680

    PowerCord2.7m(9-ft),DrawertoWall/OEMPDU,(250V/10A) 6671

    PowerCord1.5m(5-ft),DrawertoWall/OEMPDU,(250V/10A) 6672

    BenefitsTheIBMSystemNetworkingRackSwitchG8316offersthefollowingbenefits:

    High performance:This10/40GbLowLatency(880nanoseconds)Switchwith1.28Tbpsthroughputprovidesthebestcombinationoflowlatency,non-blockingline-rateswitching,andeaseofmanagement.TheG8316isalsoasingleASICdesign,whichpromisesconsistentlowerport-to-portlatencycomparedwithothervendorswithmultiplechipdesigns,whichcausesport-to-portlatencytobeinconsistentandunpredictable.

    Lower power and better cooling:TheRackSwitchG8316usesaslittleas330Wofpower,whichisafractionofthepowerconsumptionofmanycompetitiveofferings.Thefront-to-rearorrear-to-frontcoolingdesignreducesdatacenterairconditioningcostsbyhavingairflowmatchtheserversintherack.Inaddition,variablespeedfansassistinautomaticallyreducingpowerconsumption.

    High Availability:TheG8316alsocomesstandardwithhot-swapredundantpowersuppliesandfans,makingtheswitchhighlyreliable,readytouse,andeasytoserviceintheunlikelyeventofafailure.

  • 8/13/2019 Networking RackSwitch G8316

    7/16

    IBMSystemNetworkingRackSwitchG8316 7

    VM-Aware Networking:VMreadysoftwareontheswitchsimplifiesconfigurationandimprovessecurityinvirtualizedenvironments.VMreadyautomaticallydetectsvirtualmachinemovementbetweenphysicalserversandinstantlyreconfigureseachVMsnetworkpoliciesacrossVLANstokeepthenetworkupandrunningwithoutinterruptingtrafficorimpactingperformance.VMreadyworkswithallleadingVMproviders,suchasVMware,Citrix,Xen,MicrosoftHyperV,RedHatKVM,andIBMPowerVM.

    Layer 3 functionality:TheIBMswitchincludesLayer3functionality,whichprovidessecurityandperformancebenefits,asinter-VLANtrafficstayswithintheswitch.ThisswitchalsoprovidesthefullrangeofLayer3protocolsfromstaticroutesfortechnologies,suchasOpenShortestPathFirst(OSPF)andBorderGatewayProtocol(BGP)forenterprisecustomers.

    Seamless interoperability:IBMswitchesinteroperateseamlesslywithothervendors'upstreamswitches.

    Fault tolerance:TheseIBMswitcheslearnalternateroutesautomaticallyandperformfasterconvergenceintheunlikelycaseofalink,switch,orpowerfailure.TheswitchusesproventechnologieslikeL2trunkfailover,advancedVLAN-basedfailover,VRRP,andHotLink.

    OpenFlow enabled:TheRackSwitchG8316offersbenefitsofOpenFlow.OpenFlowisthenewopenapplicationprogramminginterface(API)thatenablesthenetworkadministratortoeasilyconfigureandmanagevirtualnetworksthatcontroltrafficonaper-flowbasis.Itcreatesmultipleindependent

    virtualnetworksandrelatedpolicieswithoutdealingwiththecomplexitiesoftheunderlyingphysicalnetworkandprotocols.TheG8316canalsobeusedwiththeIBMProgrammableNetworkController,whichistheIBMnetworkcontrollerthatiscompliantwithOpenFlow.

    Multicast:ThissupportsIGMPSnoopingv1,v2,andv3with2KIGMPgroups,aswellasProtocolIndependentMulticast,suchasPIMSparseModeorPIMDenseMode.

    Converged fabric:TheIBMswitchsupportsCEEandDataCenterBridging,whichisidealforstorageconnectivity(NASandiSCSI).CEEenablesclientstocombinestorage,messagingtraffic,VoIP,video,andotherdataonacommondatacenterEthernetinfrastructure.DataCenterBridginghelpswithiSCSIandFCoEwithfeaturessuchasPriority-basedFlowControl,EnhancedTransmissionSelection,andCongestionNotifications.FCoEenableshighlyefficientblockstorageoverEthernetforconsolidatingservernetworkconnectivity.Asaresult,clientscandeployasingleserverinterfaceformultipledatatypes,whichcansimplifybothdeploymentandmanagementofservernetworkconnectivity,whilemaintainingthehighavailabilityandrobustnessrequiredforstoragetransactions.

    Features and specificationsThissectionliststhekeyfeaturesandspecificationsoftheG8316.

    PerformanceTheperformancefeaturesareasfollows:

    Single-switchASICdesign100%linerateperformance1.28Tbpsnon-blockingswitchingthroughput(fullduplex)

    Submicrosecondslatency960millionpacketspersecond(mpps)

  • 8/13/2019 Networking RackSwitch G8316

    8/16

    IBMSystemNetworkingRackSwitchG8316 8

    Hardware featuresThehardwarefeaturesareasfollows:

    Models

    IBMSystemNetworkingRackSwitchG8316Rear-to-Front.Forportsintherearoftheracktoo

    matchSystemxandIBMBladeCenterdesigns.IBMSystemNetworkingRackSwitchG8316Front-to-Rear.ForportsinthefrontoftheracktoomatchairflowofIBMiDataPlexandNeXtScalesystems.

    Interfaceoptions

    SixteenQSFP+ports(40GbE),supportforoptionalbreak-outcableforsixty-four10Gboconnections.

    One10/100/1000EthernetRJ45portforout-of-bandmanagement.o

    OneUSBportformassstoragedeviceconnection.o

    Onefixedmini-USBConsoleportforconfigurationandcodechangesbythumbdrive,orbootofromUSBdrivewithnewcode.

    Server-likeportorientations,enablingshortandsimplecabling.oDimensions:17.3wide,19deep,1RUhigh

    Weight:9.98kg(22lb)

    RackInstallationKit

    GenericRackMountKit(2-post).o

    Optionalversatile4-postmountingoptionsfor19-inchserverrackordatacomrack.o

    Canbemountedverticallyorhorizontallyo

    LEDs

    SystemLEDstoindicatelinkstatus,fan,andpower.o

    StackingLEDstoindicatemaster/member(futuresupport).oAirflow

    Front-to-rearorrear-to-frontcooling.o

    Redundantvariablehot-swapspeedfansforreducedpowerdraw.o

  • 8/13/2019 Networking RackSwitch G8316

    9/16

    IBMSystemNetworkingRackSwitchG8316 9

    Figure4showstheadjustable4-postrailkit.

    Figure4.Adjustable4-postrailkit

    Figure5showstherear.

    Figure5.Rear

    Power

    Dualload-sharinghot-swapinternalpowermodules,50-60Hz,100-240Vacauto-switchingopermodule

    Typicalpowerconsumptionof330wattso

  • 8/13/2019 Networking RackSwitch G8316

    10/16

    IBMSystemNetworkingRackSwitchG8316 10

    Environmentalspecifications

    Temperature:Ambientoperating:0-40Co

    Relativehumidity:Non-condensing,operating10-90%o

    Altitude:Operating3,050m(10,000feet)o

    Heatdissipation:1127BTU/hour(typical)oMeantimebetweenfailures(MTBF):165,990hours@40Co

    Software featuresForthemostcurrentupdates,seetheIBMNetworkingOperatingSystemdatasheet,foundat:http://ibm.biz/Bdx4gn

    Herearethesoftwarefeatures:

    SecurityRADIUS,TACACS+,andLDAPoSCPo

    WireSpeedFiltering:AllowandDenyoSSHv1,v2oHTTPSSecureBBIoSecureinterfaceloginandpasswordo

    ManagementMACaddressmovenotificationoSNMPv1,v2c,andv3oRMONoDualNTPSupportoAcceptDHCPIPaddressassignmentoDHCPSnooping,DHCPOption82oDualsoftwareimagesoNetconf(XMLConfig)oSyslogConfigurationtrackingoShiftBBootMenu(PasswordRecovery/FactoryDefault)oManagementACLsoIPLoopbackoIPv6BaseRFCsoIpsecoIKEoIPv6RFCsupportacceptableforNISTcertificationoNetbooto

    VLANsPort-basedVLANso2048VLANIDssupportedo1KPort-basedVLANs(802.1Q)oPrivateVLANEdgeo

    LosslessEthernet802.1DataCenterBridgingoPriorityBasedFlowControl(PFC)oEnhancedTransmissionSelection(ETS)oDataCenterBridgeExchangeprotocol(DCBX)oFIPSnoopingoConvergedEnhancedEtherneto

  • 8/13/2019 Networking RackSwitch G8316

    11/16

    IBMSystemNetworkingRackSwitchG8316 11

    LinkAggregationStaticTrunks(EtherChannel)andLACP(802.3ad)oConfigurableTrunkHashalgorithmoEnhancedreportingofstatisticso

    SpanningTreeMultipleSpanningTree(802.1s)oRapidSpanningTree(802.1w)oPVRST+oAutoassignmentofVLANstoSTGoBPDUGuardoRootguardoLoopguardo

    QualityofserviceQoS802.1p(priorityqueues)oDiffServIPV4andIPv6oACL,IGMPProfilesoDSCPremarkingoMeteringo9MBsharedpacketbufferoWeightedrandomearlydetectionwithexplicitcongestionnotification(WRED/ECN)o

    CPUprioritypolicies(CoPP)oUserconfigurablebufferso

    RoutingprotocolsRIP/v2oOSPFv2,v3oBGPoBGPenhancementsforMD5hash,ECMP,andPassivemodesupportoDynamicBGPpeerso

    HighavailabilityLayer2failoveroHotLinksoVirtualRouterRedundancysupport(VRRP)o

    MulticastOpenFlowoMLDv2oIGMPSnoopingv2andv3oIGMPQuerieroProtocolIndependentMulticast(PIMSparseMode/DenseMode)o

    MonitoringPortmirroringoACL-basedmirroringoACLloggingoCPUloggingoVersion5oUDLDo

    VirtualizationVMreadyo

    ClientsSystemNetworkingSwitchCenter(SNSC)oisCLI(Cisco-like)oScriptableASCIIBasedCLIoBrowser-basedclientorTelneto

    StandardprotocolsDHCPClientoDHCPRelayoLLDPo128KMACTableo

  • 8/13/2019 Networking RackSwitch G8316

    12/16

    IBMSystemNetworkingRackSwitchG8316 12

    9KJumboFrameso802.3XFlowControlo

    Popular configurationsThissectiondescribestwopopularconfigurations.

    40G aggregation switch for east -west trafficAsmoreclientslooktoflattentheirnetworkingtoexploitmoreofaneast-westtrafficflowthatisrequiredbyanumberoftodaysapplicationsandespeciallyvirtualizedenvironments,theRackSwitchG8316isanidealtier-twoswitchforconnectingmultipleRackSwitchG8264switches,whicharelikelybeingusedattheedgetoconnecttomultiple10Gbportsonservers,asshowninFigure6.

    Figure6.Aggregationswitchforeast-westtraffic

  • 8/13/2019 Networking RackSwitch G8316

    13/16

    IBMSystemNetworkingRackSwitchG8316 13

    Using the RackSwitch G8316 as an edge switch for servers using 40G Ethernet adaptersForenvironmentssuchasHPCandotherswhereI/Operformanceisimportant,40Gbisincreasinginpopularity.Asmore40GbEthernetadaptersappearandcostsfallinline,andapplicationsstartlookingforthenextstepbeyond10Gb,theRackSwitchG8316istheidealsolutionforconnectingmultipleserversperrack,asshowninFigure7.

    Figure7.Aggregationswitchforeast-westtraffic

    Related publications and linksIBMOfferingInformationpage(tosearchonannouncementletters,salesmanuals,orboth):http://www.ibm.com/common/ssi/index.wss?request_locale=en

    Onthispage,enterG8316 for System x and iDataPlex,selecttheinformationtype,andthen

    clickSearch.Onthenextpage,narrowyoursearchresultsbygeographyandlanguage.

  • 8/13/2019 Networking RackSwitch G8316

    14/16

    IBMSystemNetworkingRackSwitchG8316 14

    IBMSystemNetworkingRackSwitchG8316productpublications:http://ibm.com/support/entry/portal/documentation

    ApplicationGuideoIndustry-StandardCLIReferenceoBrowser-BasedInterface(BBI)QuickGuideoMenu-basedCLICommandReferenceo

    IBMVMready:http://www.ibm.com/systems/networking/software/vmready

  • 8/13/2019 Networking RackSwitch G8316

    15/16

    IBMSystemNetworkingRackSwitchG8316 15

    Notices

    ThisinformationwasdevelopedforproductsandservicesofferedintheU.S.A.

    IBMmaynotoffertheproducts,services,orfeaturesdiscussedinthisdocumentinothercountries.ConsultyourlocalIBMrepresentativeforinformationontheproductsandservicescurrentlyavailableinyourarea.AnyreferencetoanIBMproduct,program,orserviceisnotintendedtostateorimplythatonlythatIBMproduct,program,orservicemaybeused.Anyfunctionallyequivalentproduct,program,orservicethatdoesnotinfringeanyIBMintellectualpropertyrightmaybeusedinstead.However,itistheuser'sresponsibilitytoevaluateandverifytheoperationofanynon-IBMproduct,program,orservice.IBMmayhavepatentsorpendingpatentapplicationscoveringsubjectmatterdescribedinthisdocument.Thefurnishingofthisdocumentdoesnotgiveyouanylicensetothesepatents.Youcansendlicenseinquiries,inwriting,to:

    IBMDirectorofLicensing,IBMCorporation,NorthCastleDrive,Armonk,NY10504-1785U.S.A.

    The following paragraph does not apply to the United Kingdom or any other country where such provisions areinconsistent with local law: INTERNATIONALBUSINESSMACHINESCORPORATIONPROVIDESTHISPUBLICATION"ASIS"WITHOUTWARRANTYOFANYKIND,EITHEREXPRESSORIMPLIED,INCLUDING,BUTNOTLIMITEDTO,THEIMPLIEDWARRANTIESOFNON-INFRINGEMENT,MERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE.Somestatesdonotallowdisclaimerofexpressorimpliedwarrantiesincertaintransactions,therefore,thisstatementmaynotapplytoyou.Thisinformationcouldincludetechnicalinaccuraciesortypographicalerrors.Changesareperiodicallymadetotheinformationherein;thesechangeswillbeincorporatedinneweditionsofthepublication.IBMmaymakeimprovementsand/orchangesintheproduct(s)and/ortheprogram(s)describedinthispublicationatanytimewithoutnotice.

    Anyreferencesinthisinformationtonon-IBMWebsitesareprovidedforconvenienceonlyanddonotinanymannerserveasanendorsementofthoseWebsites.ThematerialsatthoseWebsitesarenotpartofthematerialsforthisIBMproductanduseofthoseWebsitesisatyourownrisk.IBMmayuseordistributeanyoftheinformationyousupplyinanywayitbelievesappropriatewithoutincurringanyobligationtoyou.Informationconcerningnon-IBMproductswasobtainedfromthesuppliersofthoseproducts,theirpublishedannouncementsorotherpubliclyavailablesources.IBMhasnottestedthoseproductsandcannotconfirmtheaccuracyofperformance,compatibilityoranyotherclaimsrelatedtonon-IBMproducts.Questionsonthecapabilitiesofnon-IBMproductsshouldbeaddressedtothesuppliersofthoseproducts.Thisinformationcontainsexamplesofdataandreportsusedindailybusinessoperations.Toillustratethemascompletelyaspossible,theexamplesincludethenamesofindividuals,companies,brands,andproducts.Allofthesenamesarefictitiousandanysimilaritytothenamesandaddressesusedbyanactualbusinessenterpriseisentirelycoincidental.

    Anyperformancedatacontainedhereinwasdeterminedinacontrolledenvironment.Therefore,theresultsobtainedinotheroperatingenvironmentsmayvarysignificantly.Somemeasurementsmayhavebeenmadeondevelopment-levelsystemsandthereisnoguaranteethatthesemeasurementswillbethesameongenerallyavailablesystems.Furthermore,somemeasurementmayhavebeenestimatedthroughextrapolation.Actualresultsmayvary.Usersofthisdocumentshouldverifytheapplicabledatafortheirspecificenvironment.

    COPYRIGHTLICENSE:

    Thisinformationcontainssampleapplicationprogramsinsourcelanguage,whichillustrateprogrammingtechniquesonvariousoperatingplatforms.Youmaycopy,modify,anddistributethesesampleprogramsinanyformwithoutpaymenttoIBM,forthepurposesofdeveloping,using,marketingordistributingapplicationprogramsconformingtotheapplicationprogramminginterfacefortheoperatingplatformforwhichthesampleprogramsarewritten.Theseexampleshavenotbeenthoroughlytestedunderallconditions.IBM,therefore,cannotguaranteeorimplyreliability,serviceability,orfunctionoftheseprograms.

    Copyright International Business Machines Corporation 2011. All rights reserved.NotetoU.S.GovernmentUsersRestrictedRights--Use,duplicationordisclosurerestrictedbyGSAADPScheduleContractwithIBMCorp.

  • 8/13/2019 Networking RackSwitch G8316

    16/16

    IBMSystemNetworkingRackSwitchG8316 16

    ThisdocumentwascreatedorupdatedonNovember14,2013.

    Sendusyourcommentsinoneofthefollowingways:UsetheonlineContact us reviewformfoundat: ibm.com/redbooksSendyourcommentsinane-mailto:

    [email protected]:IBMCorporation,InternationalTechnicalSupportOrganizationDept.HYTDMailStationP0992455SouthRoadPoughkeepsie,NY12601-5400U.S.A.

    Thisdocumentisavailableonlineathttp://www.ibm.com/redbooks/abstracts/tips0842.html.

    Trademarks

    IBM,theIBMlogo,andibm.comaretrademarksorregisteredtrademarksofInternationalBusiness

    MachinesCorporationintheUnitedStates,othercountries,orboth.TheseandotherIBMtrademarkedtermsaremarkedontheirfirstoccurrenceinthisinformationwiththeappropriatesymbol(or),indicatingUSregisteredorcommonlawtrademarksownedbyIBMatthetimethisinformationwaspublished.Suchtrademarksmayalsoberegisteredorcommonlawtrademarksinothercountries.AcurrentlistofIBMtrademarksisavailableontheWebathttp://www.ibm.com/legal/copytrade.shtml.

    ThefollowingtermsaretrademarksoftheInternationalBusinessMachinesCorporationintheUnitedStates,othercountries,orboth:

    BladeCenterIBMiDataPlexPowerSystemsPowerVM

    RackSwitchRedbooks(logo)SystemStorageSystemxVMready

    Thefollowingtermsaretrademarksofothercompanies:

    LinuxisatrademarkofLinusTorvaldsintheUnitedStates,othercountries,orboth.

    Microsoft,andtheWindowslogoaretrademarksofMicrosoftCorporationintheUnitedStates,othercountries,orboth.Othercompany,product,orservicenamesmaybetrademarksorservicemarksofothers.