Benets Cost and space effective system
congurations thanks to smart andexible Multi Function Unit, MFU.(The MFU houses the controller,DC and Battery breakers, shunts,alarm boards and optionally discon-nection of loads and/or batteries.
Wide AC input window with highrectier DC output.
AC current input limitation possibleon rectiers. This function enables theuser to employ 10A AC breakers, orsmaller, if desired.
NETSURETM501DC Power System, -48 V DC, 1.7 20.4 kW, 35 420 A
NetSure 501 is the new more compact, and yet more exible,
DC power system from Emerson. It is especially developed for
the needs of typical telecom applications in the range between
1.7-20.4 kW.
The packaging of the NetSure 501 system congurations gives the
possibility to very space effectively house both batteries and DC
power system in 400 mm deep congurations.
Based upon factory pretested units, subrack and complete
congurations, new customer congurations and adaptations can
quickly, easily and cost effectively be created with NetSure 501,
and you can trust that the telecom norms and standards specied
for the product are always adhered to.
As the business grows, NetSure 501 is easily extended with
additional capacity and can be upgraded with supplementary
features and functions during live operation.
With NetSure 501 the process of nding a suitable location for anapplication and its power supply is facilitated, thanks to the wide
tolerance window of NetSure 501 when it e.g. comes to operating
temperature, AC input window of AC input breaker size.
6.8 kW
15.3 kW
17.0 kW
5/21/2018 NetSure 501 Brochure
2/3
A Cabling space
B DC distribution unit (extension, optional)
C Cabling space (incl. AC terminals if no distribution)
D Multi function unit
E Connection board
F Controller
G Rectier rack
H Rectier rack (extension)
I AC distribution unit (optional)
Emerson Network PowerEnergy Systems ABSE-141 82 Stockholm, SwedenPhone: +46 8 721 60 00Fax: +46 8 721 71 77
Emerson Network PowerEnergy Systems, North America1122 F Street, Lorain, OH 44052Phone: 440-246-6999Fax: 440-246-4876www.emersonnetworkpower.com/energysystems/
Emerson Network PowerCo Ltd., ChinaNo. 1 Kefa Rd., Science &Industry ParkNanshan District 518057,Shenzhen, ChinaPhone: 86-755-860 108 08www.emersonnetworkpower.com.cn
For global contact, visit:www.emersonenergy.com
EN/LZT 145 279 RA Emerson Network Power Energy Systems 2006
Technical Specications
Typical ApplicationsBase Transceiver Stations (BTS) and Node B Fiber repeatersSmall Microwave units Point of Presence (PoP)Digital Subscrib er line (DSL) Digital Loop Carrier
Electrical System Specifcation
Nominal system voltage: -48 V DCAdjustab le range for operating voltage: -42 V DC to 58 V DCOutput power, system: 20.4kW @ Vout > 48 V DCInput voltage, nominal: 200 250 V AC, 1 phase 20%Input voltage, permit ted variation: 85 300 V AC 10%Line frequenc y: 45 65 HzMaximum AC input fuse: normally 16A, but the recti er can limit
the maximum input AC if smaller AC input fuseis required
Mechanical system SpecifcationDimensions: (HxDxW),
wall/batte ry rack mounted cabinet: 360/450x400x600 mmDimensions (HxDxW),
stand- alone power cabinet: 800/1200/1600/1800x400x600 mmDimensions (HxDxW),
stand- alone power cabinet: 1200/1600/1800/2000/2200x600x60 0 mmDetails: Front access and top cabling
Environmental System SpecifcationTemperature range, operating -5C to +65C (full power up to +45C)Relative humidit y, operating
5/21/2018 NetSure 501 Brochure