Magnetic Particle Testing

• When a ferromagnetic material is magnetised the flux lines flow inside the component

• When there is a discontinuity in the material there is flux leakage

• The leaking flux attracts a magnetic medium resulting in an indication.

Page 2: NDT MT nds1
Page 3: NDT MT nds1
Page 4: NDT MT nds1

Types of magnetisation

• Longitudinal Magnetisation

• Circular Magnetisation

o AC Magnetisation

o DC Magnetisation

o HWDC magnetisation

Page 5: NDT MT nds1

MAGNETIC PARTICLE TESTINGLONGITUDINAL MAGNETISATION

COIL METHOD YOKE METHOD.

Page 6: NDT MT nds1

HEAD SHOT METHOD

PROD METHOD CENTRAL CONDUCTOR

Types of Magnetisation - Circular Magnetisation

Page 7: NDT MT nds1

KETO RING

Page 8: NDT MT nds1

PIE-GAUGE

GROOVE BLOCK

Page 9: NDT MT nds1

CURRENT REQUIREMENTLONGITUDINAL FIELD

CIRCULAR FIELD

Page 10: NDT MT nds1
Page 11: NDT MT nds1

Magnetic field within article

Magnetic material

MAGNETIC FIELD DISTRIBUTION

Page 12: NDT MT nds1

MAGNETIC FIELD DISTRIBUTION

Page 13: NDT MT nds1

DISTORTED FIELD

Page 14: NDT MT nds1

MAGNETIC MEDIUM

DryWet

• Fluorescent – Requires Ultra violet lamp in darkened area – More sensitive than

• Non – Fluorescent

Page 15: NDT MT nds1

Magnetic Medium - Dry

• Medium about 30 – 50 microns

• Mixture of spherical and elongated powders

• Spherical shape helps in mobility

• Elongated shape helps in alignment to magnetic field

Dry Medium

Page 16: NDT MT nds1

MAGNETIC MEDIUM - WET

• Oxides of iron used in suspension with water, kerosene, petroleum oil.

• Size : 20- 30 microns• More sensitive than dry

medium

Page 17: NDT MT nds1

STAGES OF MAGNETIC PARTICLE TESTING

• Pre - Cleaning

• Magnetisation

• Applying magnetic medium

• Inspection

• Post cleaning

• Demagnetization

Page 18: NDT MT nds1

Magnetisation

• Magnetisation to be applied in two mutually perpendicular direction

• Magnetic medium to be applied when the magnetisation is ‘ON’

• Adequacy of field to be checked by field indicator ( Pie Gage )

• Magnetic medium could be wet or dry / Fluorescent or non-fluorescent

Page 19: NDT MT nds1

MT Indications

Page 20: NDT MT nds1

MT Indications

Page 21: NDT MT nds1

MT Indications

Page 22: NDT MT nds1

MT Indications

Page 23: NDT MT nds1

MT INDICATIONS

Page 24: NDT MT nds1

MT INDICATIONS

Page 25: NDT MT nds1

MT INDICATIONS

Forging Burst

Page 26: NDT MT nds1

MT INDICATIONS

Page 27: NDT MT nds1

MT INDICATIONS

Page 28: NDT MT nds1

MT INDICATIONS

Page 29: NDT MT nds1

MT INDICATIONS

Page 30: NDT MT nds1

MT INDICATIONSLigament crack

Page 31: NDT MT nds1

MTNON-RELEVANT INDICATION

Page 32: NDT MT nds1

LOW PERMEABILITY(HARD )

HIGH PERMEABILITY (SOFT)

MTNON-RELEVANT INDICATION

Page 33: NDT MT nds1

Tool

Carbide tip

Indication

MTNON-RELEVANT INDICATION

Page 34: NDT MT nds1

MT False Indication

Page 35: NDT MT nds1

Demagnetisation• Residual magnetism affects

further operation such as welding.

• Demagnetisation is preferably done with AC

• Object is moved slowly away from coil

• After demagnetisation residual magnetism is checked with gauss meters