8
For industrial pump, fan, compressor and other industrial applications. NEMA Frames 5800-8000 500-7500 HP IEC Frames 400-PV900 400-5600 kW MV Induction Motors GE Power Conversion

MV Induction Motors 500-7500 HP, 400-5600 kW

Embed Size (px)

Citation preview

Page 1: MV Induction Motors 500-7500 HP, 400-5600 kW

For industrial pump, fan, compressor and other industrial applications.

NEMA Frames 5800-8000500-7500 HPIEC Frames 400-PV900400-5600 kW

MV Induction Motors

GEPower Conversion

Page 2: MV Induction Motors 500-7500 HP, 400-5600 kW

Experience MattersFor over 100 years, GE has produced countless medium voltage induction machines for the petrochemical, power generation, mining and minerals, water and wastewater industries. These motors are commonly used for centrifugal compressors, blowers, boiler feed pumps, crushers and grinders, multi-stage high pressure pumps such as water injection or pipeline applications.

StandardsGE motors are designed for, but are not limited to these critical industry standards:NEMA MG1IEC 60034-1ANSI C50.41IEEE 112API 541 & 547Applicable ISO, AFBMA, ANSI, ASME, and ASTM requirements

QualityOur world-class testing facility has the capability of meeting a wide range of NEMA, IEC and API motor requirements. GE is dedicated to manufacturing excellence. Our facilities are ISO 9001 Certified with over 20 years of Six Sigma process enhancements and best practice implementations. Our commitment is to deliver the highest quality design to fit your system requirements with service to exceed your expectations.

Page 3: MV Induction Motors 500-7500 HP, 400-5600 kW

Reduction of ResonancesGE supplies both flexible and rigid rotor technology. All

machines 1800 rpm and below have rigid rotors as defined

by API. Use of the latest engineering simulation tools and

modern modal testing equipment makes it possible for GE

to assure shaft resonances do not impede operation of the

machine in the specified speed range.

Superior DesignMeets or exceeds API 541 requirements for Petroleum & Chemical ApplicationsGE provides machines that are fully compliant to API 541

standards, globally recognized among the most stringent.

You can be assured that you are getting a well-designed and

reliable product, optimized for your specific application.

Inverter DutyThe insulation system meets the requirements of NEMA MG-1,

part 31. If required, a shaft grounding device is installed to

reduce shaft voltage. Both bearings are insulated and the

drive end bearing is grounded. Our cage induction motors are

certified for use with the GE MV4, MV6 and MV7000 range of

variable frequency drives.

Stator frames are designed using powerful FEA tools. The design tools confirm safety margins, and assure resonances are well outside the operating region.

Improved ventilation and cooling has been achieved with a new internal fan design.

Page 4: MV Induction Motors 500-7500 HP, 400-5600 kW

Rotor ConstructionThe magnetic circuit consists of punched thin steel disks

assembled to form a laminated core mounted on the shaft. The

laminations are coated with a temperature stable insulating

film to reduce magnetic losses yet maintain dimensional

stability in the face of severe thermal and mechanical stresses.

The rotor winding consists of a number of uninsulated metal

bars in the outer surface of the magnetic core parallel to the

shaft and short circuited by metal rings at both ends.

BearingsGE uses self-aligning spherical seat sleeve bearings per DIN

31693/4. Seal additions are also available to meet IP-56

requirements. Anti-friction bearings are available with

grease in a sealed housing to avoid contamination meeting

IP56 protection.

Built for DurabilityStator ConstructionLaminations are precision punched from high quality, low loss

electrical sheet steel with a temperature stable insulating film.

The magnetic core consists of ring laminations compressed

and completely wound before the core package is inserted

into the frame.

Insulation SystemGE uses an epoxy solventless resin vacuum-pressure-im-

pregnation (VPI) process assuring long life. For line voltages

of 5000 Volts and above, a semi-conducting armor is applied

to the slot portion and beyond the core to provide corona

protection. The binding agent is GE’s third generation epoxy

resin, selected and tested to IEEE-1776. The coils receive a

protective armor of heavy glass tape for protection against

mechanical shock and abrasion. Custom Polyseal® is a sealed

winding insulation system that meets the requirements of

NEMA MG1 20.18..

It is available upon

request to operate in

severe environments

containing moisture,

oil, chemicals and

salt water.

The stator assembly is configured for increased air flow which improves heat transfer and provides a more compact design.

Self-aligning spherical seat sleeve bearings have features designed to keep the oil in and the dirt out.

Copper bars are brazed to their endrings, and aluminum bars are welded to their endrings.

Copper Conductor

Ground Wall Insulation

Turn Insulation

Strand Insulation

Page 5: MV Induction Motors 500-7500 HP, 400-5600 kW

Bearing

Upper Endshield

Chamber (Enclosed or Open Types)

Frame

Stator

Shaft

Rotor Lamination

Lower Endshield

VerticalAccurate Frequency Response Design System resonance can shorten the life of your equipment.

GE invested in the development and calibration of a new

Reed Critical Frequency (RCF) prediction tool. It arms our

engineers with the accurate data they need to create custom

designs for specific application challenges.

Frame Design - BenefitsLarge inspection windows on both ends of the frame ensure

easy maintenance and inspection access. The modular frame

design accommodates multiple cooling, bearing loading and

protection options without changing

the motor stator frame.

Rotor DesignShaft FEA modeling (including Torsional, Radial and Axial

loads) help ensure rotor designs meet specifed application

requirements.

Bearing DesignAPI compliant options are available for the rolling

element and sleeve bearing

Wound RotorEnergy Recovery SystemGE wound rotor induction motors are designed to operate

with Slip Energy Recovery drives within a standard range of

80% to 110% of the rated speed. Every design is optimized

to suit each application and to provide maximum energy

savings, effective speed control, and high reliability.

Rotor Construction

The rotor has a three-phase insulated winding. Rotor winding

terminals are brought out through rotating slip rings and

stationery brushes. These terminals are used to connect

an external resistor in series with the rotor winding

in order to control the motor accelerating torque and

associated current.

Brush Lifting Device In a traditional application as the motor achieves nominal

speed, the starting resistor is shorted out through the brushes

between the slip rings. This shortens the life of the brushes

and adds extra wear in the motor. An optional solution from

GE, called a Brush Lifting Device, is an integrated mechanism,

which shorts the slip rings and lifts the brushes at nominal

speed to avoid this wear.

Page 6: MV Induction Motors 500-7500 HP, 400-5600 kW

5000 3750 8400 8400 8400 8400 8400 85005500 4100 8400 8400 8400 8500 8500 85006000 4450 8400 8400 8400 8500 8500 85007000 5200 8400 8500 8500 8500 8500 85007500 5600 8500 8500 8500 8500 8500 8500

Vertical MV Induction MotorsHP kW A* B* A B A B A B A B A B A B A B

8200 8200 8200 8200500 3708200 8200 8200 8200 8200 8200 8200 82001000 750 8300 8300

8200 8200 8200 8200 8200 8200 82001500 1100 8300 8300 8300 8300 83008200 8200 8200 8200 8200 82002000 1500 8300 8300 8300 8300 8300 83008200 8200 8200 82002500 1900 8300 8300 8300 8300 8300 8300 85008200 8200 82003000 2200 8300 8300 8300 8300 8300 8300 8500 850082003500 2600 8300 8300 8300 8300 8300 8300 8500 8500 8500 850082004000 3000 8300 8300 8300 8300 8500 8500 8500

4500 3400 8300 8300 8300 8300 8500 85005000 3700 8300 8300 8300 8300 8500 8500 85005500 4100 8300 8300 8300 8500 8500 85006000 4500 8300 8300 85006500 4900 83007000 52007500 56008000 60008500 6300

Horizontal Wound Rotor MV Induction MotorsHP kW A B A B A B A B

1000 750 8200 8200 8200 8200 8200 8200 8200 82001500 1100 8200 8200 8200 8200 8200 8200 8200 82002000 1500 8200 8200 8200 8200 8200 8200 8200 82002500 1900 8200 8200 8200 8200 8200 8200 8200 82003000 2200 8200 8200 8200 8300 8200 8200 8200 83003500 2600 8200 8300 8300 8300 8200 8300 8300 84004000 3000 8300 8300 8300 8400 8300 8300 8300 84004500 3400 8300 8400 8400 8400 8300 8400 8400 84005000 3700 8300 8400 8400 8300 8400 8400 84005500 4100 8400 8400 8400 8500 8400 8400 84006000 4500 8400 8500 8500 8500 8400 8400 84006500 4900 8400 8500 8500 8500 84007000 5200 8400 8500 8500 8500 84007500 5600 8500 8500 8500 84008000 6000 8500 8500 85008500 6300 8500 85009000 6700 85009500 7000 8500

10000 7500 850010500 7800 8500

Horizontal MV Induction MotorsHP kW A B A B A B500 400 8200 8200 8200 8200 8200 8200600 450 8200 8200 8200 8200 8200 8200700 500 8200 8200 8200 8200 8200 8200800 600 8200 8200 8200 8200 8200 8200900 650 8200 8200 8200 8200 8200 8200

1000 750 8200 8200 8200 8200 8200 83001250 950 8200 8200 8200 8200 8300 83001500 1100 8200 8200 8200 8200 8300 83001750 1300 8200 8200 8200 8300 8300 83002000 1500 8200 8200 8300 8300 8300 84002250 1700 8200 8300 8300 8300 8300 84002500 1850 8300 8300 8300 8300 8300 84003000 2250 8300 8300 8300 8400 8400 84003500 2600 8300 8300 8300 8400 8400 84004000 3000 8300 8400 8400 8400 8400 8400

A = WPI / WPII / TEWAC; IP23 / IP44W / IP54 / IP56B = TEAAC; IP54 / IP56

60Hz. shown, 50Hz. Available. These ratings are based on 4.1 kV. Enclosures for other voltages may be sized differently. Contact your GE representative for more information.

500630

400450

4 Poles 1800 RPM

6 Poles 6600V

8 Poles 6600V

6 Poles 4000V

2 Poles 4 Poles 6 Poles

8 Poles 4000V

6 Poles 1200 RPM

8 Poles 900 RPM

10 Poles 720 RPM

12 Poles 600 RPM

14 Poles 514 RPM

16 Poles 450 RPM

18 Poles 400 RPM

Ratings

* Enclosures

4500 3350

500560

710630

PV900PV800PV630PV500

Product Offering

Totally Enclosed Air-to-Air Cooled(TEAAC) - IP54 or IP56

Weather Protected (WPI) - IP23(WPII) - IP24W and IP44W

Totally Enclosed Water-to-Air Cooled(TEWAC) - IP54 or IP56

Weather Protected (WPI) - IP23(WPII) - IP24W and IP44W

Page 7: MV Induction Motors 500-7500 HP, 400-5600 kW

Rotating Machine FactoriesConverter FactoriesBusiness Centers

CompleteProductOffering

InnovativeTechnology

ProvenExperience

World-ClassService

The GEAdvantage

Few manufacturers can claim the depth and breadth of experience that GE has in building and delivering electrical and mechanical solutions for customers.

GE offers a complete portfolio of rotating machines.

GE has the global resources and capabilities to maximize the performance and reliability of your machines.

GE is constantly innovating product technologies to meet and exceed customer expectations.

Global Expertise

Page 8: MV Induction Motors 500-7500 HP, 400-5600 kW

www.gepowerconversion.com© 2014 General Electric Company. All rights reserved.GEA31319 (7/2014)

Additional OptionsMonitoring/Protection/Accessories

Vibration displacement, velocity or acceleration

Temperature winding, cooling air, cooling water, bearing and bearing oil

Enclosure anti-condensation heaters, water leakage, differential pressure

Electrical current transformers, surge capacitors, surge arresters, partial discharge couplers

Mechanical soleplates, coupling guard supports, speed sensing

MAIN OFFICES

Australia, Botany Tel: +61 (0) 2 8313 9980

Brazil, São Paulo Tel: +55 11 3614 1930

Canada, Mississauga Tel: + 1 905 858 5100

Chile, Santiago Tel: + 56 2 271 92200

China, Shanghai Tel: +86 21 6498 2600

France, Massy Tel: +33 1 77 31 20 00

Germany, Berlin Tel: +49 30 7622 0

India, Chennai Tel: +91 44 4968 0000

Japan, Tokyo Tel: +81 3 5544 3852

Russia, Moscow Tel: +7 495 981 13 13

Singapore Tel: +65 6332 0940

South Africa, Midrand Tel: +2711237 0000

South Korea, Busan Tel: +82 51 710 9015

UAE, Dubai Tel: +971 44296161

UK, Rugby Tel: +44 1788 563 563

USA, Pittsburgh Tel: +1 412 967 0765