12
FORM NO. GFJ-552 Features 92% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all units Direct Spark Ignition for reliability and longevity Water Management System with patented Blocked Drain Sensor Heat exchanger is removable for improved serviceability. Aluminized steel primary and stainless steel secondary construction provide maximum corrosion resistance and thermal fatigue reliability. Low profile “34 inch” cabinet ideal for space constrained installations. Blower Shelf design – serviceable in all furnace orientations Pre marked hoses – insures proper system drainage Vent with 2" or 3" PVC Replaceable Collector box Hemmed edges on cabinet and doors Quarter turn fasteners for tool less access Integrated control boards feature dip switches for easy system set up Self priming condensate trap Solid bottom included MULTI POSITION GAS FURNACE Manufactured for Fujitsu General America, Inc. Fairfield, NJ FF***TS92 Series 92% A.F.U.E.† Input Rates from 40 to 115 kBTU [11.72 to 33.71 kW] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.

MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

  • Upload
    donhi

  • View
    219

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

FORM NO. GFJ-552

Features■ 92% residential gas furnace CSA certified

■ 4 way multi-poise design

■ 7-Segment LED all units

■ Direct Spark Ignition for reliability and longevity

■ Water Management System with patented BlockedDrain Sensor

■ Heat exchanger is removable for improved serviceability.Aluminized steel primary and stainless steel secondaryconstruction provide maximum corrosion resistance andthermal fatigue reliability.

■ Low profile “34 inch” cabinet ideal for space constrainedinstallations.

■ Blower Shelf design – serviceable in all furnace orientations

■ Pre marked hoses – insures proper system drainage

■ Vent with 2" or 3" PVC

■ Replaceable Collector box

■ Hemmed edges on cabinet and doors

■ Quarter turn fasteners for tool less access

■ Integrated control boards feature dip switches for easy system set up

■ Self priming condensate trap

■ Solid bottom included

MULTI POSITIONGAS FURNACE

Manufactured for

Fujitsu General America, Inc.Fairfield, NJ

FF***TS92 Series92% A.F.U.E.†Input Rates from 40 to 115 kBTU[11.72 to 33.71 kW]

✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance withDepartment of Energy test procedures.

Page 2: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

2 Fujitsu General America, Inc.

Table of ContentsFF***TS92 Series

TABLE OF CONTENTSStandard & Optional Equipment ......................................................................3

Physical Data & Specifications ........................................................................4

Model Number Identification ............................................................................5

Dimensional Data............................................................................................6

Blower Performance Data................................................................................7

Accessories....................................................................................................8

Limited Warranty ............................................................................................9

Page 3: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

Fujitsu General America, Inc. 3

Standard & Optional EquipmentFF***TS92 Series

PRIMARY AND SECONDARYHEAT EXCHANGER

IN-SHOT BURNERS

PRESSURE SWITCHES

DRAFTINDUCER

CONTROLBOARD

GAS VALVE AND MANIFOLD

DIRECT SPARK IGNITION &REMOTE SENSOR

STANDARD EQUIPMENTCompletely assembled and wired; blocked drain sensor, 7segment LED and marked hoses; heat exchanger; primary:aluminized steel, secondary: 29-4C stainless steel; solid bot-tom; induced draft; pressure switches; redundant main gascontrol; blower compartment door safety switch; solid statetime on/off blower control; limit controls; manual shut-offvalve; 100% safety lock out; cool fan off delay; field selectableheat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronicair cleaner connections; twinning (built-in) features; humidifierconnections; humidifier on/off delay; low speed continuous fanoption; single speed option for heating and cooling applica-tions; transformer; direct drive, multi-speed Constant Torqueelectrically commutated motor. (Please note: a thermostat isnot included as standard equipment.)

OPTIONAL EQUIPMENTSide and bottom filter racks; return air cabinet for all sizes.NOTE: Furnace is not listed for use with fuels other than natural

or L.P. (propane) gas.All models can be converted by a qualified distributor or localservice dealer to use L.P. (propane) gas without changing burn-ers. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optionalaccessories from a parts distributor.For L.P. (propane) operation, refer to Conversion Kit Index Form.

WARNINGTHIS FURNACE IS NOT APPROVED

OR RECOMMENDEDFOR USE IN MOBILE HOMES

REMOTESENSOR

BLOCKED DRAINSENSOR

CONSTANT TORQUEELECTRICALLYCOMMUTATED MOTOR

Page 4: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

4 Fujitsu General America, Inc.

Physical Data & SpecificationsFF***TS92 Series

Physical Data and Specifications—Upflow ModelsU.S. and Canadian Models

MODEL NUMBERS FF40173TS92M FF60173TS92M FF70173TS92M FF85215TS92M FF100215TS92M FF115245TS92M

HIGH FIRE INPUT BTU/HR [kW] ➀ 42,000 [12.31] 56,000 [16.41] 70,000 [20.50] 84,000 [24.61] 98,000 [38.71] 112,000 [32.82]HEATING CAPACITY BTU/HR [kW] 40,320 [11.82] 53,760 [15.75] 67,200 [19.68] 80,640 [23.63] 94,080 [37.16] 107,520 [31.51]

HIGH ALTITUDE OUTPUT 10% DERATE [kW] ➁

36,288 [10.64] 48,384 [14.18] 60,480 [17.72] 72,576 [21.28] 84,672 [24.81] 96,768 [28.36]

BLOWER (D x W)[mm]

11 x 7[279 x 178]

11 x 8[279 x 203]

11 x 8[279 x 203]

11 x 10[279 x 254]

11 x 10[279 x 254]

11 x 11[279 x 279]

MOTOR H.P. [W]–TYPE

1/2 [373]-5-ContstantTorque ECM

1/2 [373]-5-ContstantTorque ECM

1/2 [373]-5-ContstantTorque ECM

1 [746]-5-ContstantTorque ECM

1 [746]-5-ContstantTorque ECM

1 [746]-5-ContstantTorque ECM

MIN. CIRCUIT AMPACITY 8.00 10.00 10.00 13.00 15.00 14.00MIN. OVERLOAD PROTECTION DEVICE 15.00 15.00 15.00 20.00 20.00 20.00

MAX. OVERLOADPROTECTION DEVICE 15.00 15.00 15.00 20.00 20.00 20.00

MOTOR FULL LOAD AMPS 4.0 6.8 6.8 8.3 8.3 8.3HEATING SPEED MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGHCOOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGHMINIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa] .18 [.045] .20 [.050] .23 [.057] .28 [.070] .28 [.070] .28 [.070]

MAXIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa] .9 [0.224] .9 [0.224] .9 [0.224] .9 [0.224] .9 [0.224] .9 [0.224]

HEATING CFM @ .2" [.049 kPa]W.C. E.S.P. [L/s] 982 [463] 913 [431] 1113 [525] 1574 [743] 1651 [779] 1524 [719]

COOLING CFM @ .5" [.124 kPa]W.C. E.S.P. [L/s] 1239 [585] 1227 [579] 1198 [565] 1833 [865] 1975 [932] 1748 [825]

TEMPERATURE RISE-HIGH FIRERANGE IN DEGREES °F [°C]

25 - 55[14 -31]

35 - 65[19 - 36]

40 - 70[22 - 39]

35 - 65[19 - 36]

35 - 65[19 - 36]

45 - 75[25 - 42]

APPROX. SHIPPING WEIGHT (LBS.) [kg] 123.5 [56] 128 [58] 132 [60] 147.5 [67] 152 [69] 165 [75]

AFUE ➂ 92.00% 92.00% 92.00% 92.00% 92.00% 92.00%

NOTES: All models are 115V, 60HZ, 1 phase Gas connection size for all models is 1/2" [13 mm] N.P.T. ➀ Installation instructions for high altitude derate. ➁ Canadian installations only. ➂ In accordance with D.O.E. test procedures. *S=Standard ModelsNOTE: Standard model complies with California low nox requirements.

[ ] Designates Metric Conversions

Page 5: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

Fujitsu General America, Inc. 5

Model Number IdentificationFF***TS92 Series

FF 40 17 3 T S 92 M

Product Capacity Width Airflow Motor Speed Efficiency Orientation

Furnace 40 - 42,000 [12.31 kW]60 - 56,000 [16.41 kW]70 - 70,000 [20.51 kW]85 - 84,000 [24.62 kW]

100 - 98,000 [28.72 kW]115 - 112,000 [32.82 kW]

17"21"24"

3 = 3 Ton5 = 5 Ton

T = Constant Torque S = Single Stage 92 = 92% M = Multipoise

[ ] Designates Metric Conversions

Model Number Identification

Page 6: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

6 Fujitsu General America, Inc.

Dimensional DataFF***TS92 Series

MODELFF***TS92

LEFTSIDE

MINIMUM CLEARANCE (IN.) [mm]SHIP

WGTS.

FLANGE DIMENSIONSRIGHTSIDE BACK TOP FRONT VENT A B C

040 0 0 0 1 [25] 2 [51] 0 123.5 [56] 171/2 [445] 1617/64 [413] 1613/64 [412]060 0 0 0 1 [25] 2 [51] 0 128 [58] 171/2 [445] 1617/64 [413] 1613/64 [412]070 0 0 0 1 [25] 2 [51] 0 132 [60] 171/2 [445] 1617/64 [413] 1613/64 [412]085 0 0 0 1 [25] 2 [51] 0 147.5 [67] 21 [533] 1949/64 [502] 1945/64 [500]100 0 0 0 1 [25] 2 [51] 0 152 [69] 21 [533] 1949/64 [502] 1945/64 [500]115 0 0 0 1 [25] 2 [51] 0 165 [75] 241/2 [662] 2317/64 [591] 2313/64 [589]

UNIT DIMENSIONS(CLEARANCE TO COMBUSTIBLES)

UNIT DIMENSIONS(CLEARANCE TO COMBUSTIBLES)

*A service clearance of at least 24" is recommended in front of all furnaces [ ] Designates Metric ConversionsSupply and return depicted as upflow configuration.Flange configuration will vary depending on installation orientation.

Page 7: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

Fujitsu General America, Inc. 7

Blower Performance DataFF***TS92 Series

FUR

NAC

EM

OD

EL

BLO

WER

SIZE

[mm

]

MO

TOR

H.P

.[W

]

MO

TOR

TAP

MO

TOR

LEAD

WIR

ECO

LOR

SPEE

DCF

M [

L/s]

AIR

DEL

IVER

YEX

TER

NAL

STA

TIC

PRES

SUR

E IN

CHES

WAT

ER C

OLU

MN

[kP

a]

0.1

[.02

]0.

2 [.

05]

0.3

[.07

]0.

4 [.

10]

0.5

[.12

]0.

6 [.

15]

0.7

[.17

]0.

8 [.

19]

0.9

[.22

]

FF40

173

TS92

M11

x 7

[279

x 1

78]

1/2

[373

]

1R

edLo

w87

4 [4

13]

820

[387

]76

5 [3

61]

710

[335

]65

8 [3

11]

575

[271

]52

3 [2

47]

482

[228

]44

8 [2

11]

2Ye

llow

Med

ium

Low

*10

29 [4

86]

982

[463

]93

0 [4

39]

881

[416

]83

3 [3

93]

780

[368

]71

6 [3

38]

665

[314

]62

1 [2

93]

3Pu

rple

Med

ium

1098

[518

]10

55 [4

98]

1008

[476

]96

2 [4

54]

920

[434

]87

0 [4

11]

822

[388

]75

5 [3

56]

705

[332

]

4Bl

ueM

ediu

m H

igh*

*12

53.6

[592

]12

09.1

[571

]11

64.4

[550

]11

28.1

[532

]10

82.2

[511

]10

43.7

[493

]10

00 [4

72]

960

[453

]90

7.2

[428

]

5Bl

ack

Hig

h13

80.6

[652

]13

45.5

[635

]13

13.1

[620

]12

76 [6

02]

1239

.2 [5

85]

1202

.3 [5

67]

1166

[550

]11

32.7

[535

]10

98.9

[519

]

FF60

173

TS92

M11

x 8

[279

x 2

03]

1/2

[373

]

1R

edLo

w81

8 [3

86]

766

[362

]72

0 [3

40]

668

[315

]59

4 [2

80]

548

[259

]49

4 [2

33]

444

[210

]41

6 [1

96]

2Ye

llow

Med

ium

Low

*96

8 [4

57]

913

[431

]88

5 [4

18]

841

[397

]79

6 [3

76]

739

[349

]68

5 [3

23]

641

[303

]59

6 [2

81]

3Pu

rple

Med

ium

1018

[480

]98

1 [4

63]

931

[439

]90

3 [4

26]

860

[406

]81

5 [3

85]

756

[357

]70

3 [3

32]

656

[310

]

4Bl

ueM

ediu

m H

igh*

*11

73 [5

54]

1142

[539

]11

08 [5

23]

1059

[500

]10

25 [4

84]

989

[467

]95

1 [4

49]

912

[430

]85

5 [4

04]

5Bl

ack

Hig

h13

38 [6

31]

1327

[626

]12

88 [6

08]

1245

[588

]12

27 [5

79]

1193

[563

]11

65 [5

50]

1134

[535

]10

99 [5

19]

FF70

173

TS92

M11

x 8

[279

x 2

03]

1/2

[373

]

1R

edLo

w94

7 [4

47]

908

[429

]87

1 [4

11]

834

[394

]79

6 [3

76]

755

[356

]71

6 [3

38]

681

[321

]65

6 [3

10]

2Ye

llow

Med

ium

Low

1044

[493

]99

7 [4

71]

968

[457

]93

4 [4

41]

902

[426

]86

2 [4

07]

828

[391

]79

5 [3

75]

765

[361

]

3Pu

rple

Med

ium

**11

48 [5

42]

1113

[525

]10

92 [5

15]

1056

[498

]10

29 [4

86]

995

[470

]96

2 [4

54]

928

[438

]89

5 [4

22]

4Bl

ueM

ediu

m H

igh*

*12

13 [5

72]

1180

[557

]11

55 [5

45]

1126

[531

]10

96 [5

17]

1062

[501

]10

32 [4

87]

993

[469

]96

9 [4

57]

5Bl

ack

Hig

h13

24 [6

25]

1283

[606

]12

54 [5

92]

1221

[576

]11

98 [5

65]

1169

[552

]11

41 [5

38]

1107

[522

]10

80 [5

10]

FF85

215

TS92

M11

x 1

0[2

79 x

254

]1

[746

]

1R

edLo

w14

06 [6

64]

1355

[640

]13

00 [6

14]

1230

[581

]11

75 [5

55]

1111

[524

]10

59 [5

00]

1006

[475

]94

1 [4

44]

2Ye

llow

Med

ium

Low

*16

56 [7

82]

1621

[765

]15

74 [7

43]

1533

[723

]14

85 [7

01]

1434

[677

]13

75 [6

49]

1328

[627

]12

81 [6

05]

3Pu

rple

Med

ium

1692

[799

]16

53 [7

80]

1606

[758

]15

57 [7

35]

1508

[712

]14

59 [6

89]

1409

[665

]13

63 [6

43]

1312

[619

]

4Bl

ueM

ediu

m H

igh*

*18

81 [8

88]

1831

[864

]18

04 [8

51]

1757

[829

]17

13 [8

08]

1668

[787

]16

28 [7

68]

1568

[740

]15

28 [7

21]

5Bl

ack

Hig

h19

78 [9

34]

1942

[917

]19

06 [9

00]

1862

[879

]18

33 [8

65]

1793

[846

]17

51 [8

26]

1702

[803

]16

52 [7

80]

FF10

0215

TS92

M11

x 1

0[2

79 x

254

]1

[746

]

1R

edLo

w16

37 [7

73]

1593

[752

]15

45 [7

29]

1494

[705

]14

41 [6

80]

1382

[652

]13

29 [6

27]

1274

[601

]12

36 [5

83]

2Ye

llow

Med

ium

Low

*17

45 [8

24]

1697

[801

]16

51 [7

79]

1600

[755

]15

60 [7

36]

1500

[708

]14

43 [6

81]

1394

[658

]13

42 [6

33]

3Pu

rple

Med

ium

1766

[833

]17

23 [8

13]

1686

[796

]16

33 [7

71]

1585

[748

]15

37 [7

25]

1482

[699

]14

28 [6

74]

1380

[651

]

4Bl

ueM

ediu

m H

igh*

*19

67 [9

28]

1929

[910

]18

95 [8

94]

1852

[874

]18

05 [8

52]

1754

[828

]17

08 [8

06]

1668

[787

]16

12 [7

61]

5Bl

ack

Hig

h21

37 [1

009]

2102

[992

]20

62 [9

73]

2020

[953

]19

75 [9

32]

1946

[918

]19

08 [9

00]

1817

[858

]16

85 [7

95]

FF11

5245

TS92

M11

x 1

1[2

79 x

279

]1

[746

]

1R

edLo

w14

76 [6

97]

1432

[676

]14

06 [6

64]

1332

[629

]12

91 [6

09]

1247

[589

]12

07 [5

70]

1163

[549

]11

17 [5

27]

2Ye

llow

Med

ium

Low

*16

15 [7

62]

1568

[740

]15

24 [7

19]

1487

[702

]14

52 [6

85]

1401

[661

]13

56 [6

40]

1325

[625

]12

78 [6

03]

3Pu

rple

Med

ium

**17

09 [8

07]

1674

[790

]16

33 [7

71]

1591

[751

]15

51 [7

32]

1519

[717

]14

77 [6

97]

1436

[678

]13

97 [6

59]

4Bl

ueM

ediu

m H

igh

1772

[836

]17

46 [8

24]

1706

[805

]16

67 [7

87]

1627

[768

]15

93 [7

52]

1553

[733

]15

21 [7

18]

1482

[699

]

5Bl

ack

Hig

h18

87 [8

91]

1852

[874

]18

28 [8

63]

1784

[842

]17

48 [8

25]

1713

[808

]16

78 [7

92]

1648

[778

]16

19 [7

64]

*Low

Sta

tic H

eatin

g Sp

eed

**Hi

gh S

tatic

Hea

ting

Spee

dSh

aded

cel

ls in

dica

te s

tatic

pre

ssur

es a

t whi

ch th

at m

otor

tap

can

be u

sed

for h

eatin

g sp

eed.

Ins

talle

r mus

t ver

ify s

tatic

pre

ssur

e. I

f sta

tic p

ress

ure

is n

ot w

ithin

the

limits

not

ed h

ere,

the

high

er h

eatin

g sp

eed

tap

MUS

T be

use

d.Do

NOT

use

the

spee

d ta

ps a

nd/o

r sta

tic p

ress

ures

whi

ch d

o no

t fal

l int

o th

e sh

aded

cel

ls o

n th

is ta

ble.

This

tabl

e is

for r

efer

ence

. Th

e te

chni

cian

/inst

alle

r mus

t ver

ify fu

rnac

e is

ope

ratin

g w

ithin

the

publ

ishe

d ris

e ra

nge

befo

re c

ompl

etin

g th

e in

stal

latio

n.

[ ]

De

sig

na

tes M

etr

ic C

on

ve

rsio

ns.

Page 8: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

8 Fujitsu General America, Inc.

AccessoriesFF***TS92 Series

FILTER RACK FILTER SIZES* INCHES [mm]

MODELRXGF-CB(UPFLOW/

HORIZONTAL)

RXGF-CD(UPFLOW)

RXGF-CC(DOWNFLOW)

FF4017 153/4 x 25[400 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

FF6017 153/4 x 25[400 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

FF7017 153/4 x 25[400 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

FF8521 191/4 x 25[489 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

FF10021 191/4 x 25[489 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

FF11524 223/4 x 25[578 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

FOR HIGH ALTITUDES:NOTE: For Canadian installations only, an optional derate (manifold

gas pressure reduction) method may be used to adjust thefurnace for altitude. See Installation Instructions for moreinformation. This optional method may NOT be used for U.S.installations. See installation instructions as appropriate orificechange is required.

L.P. CONVERSION KIT: RXGJ-FP33

CONDENSATE PUMP KIT: PROSTOCK & 1PCB151TUL

DOWNFLOW/HORIZONTAL CONVERSION KIT: RXGY-CK

DOWNFLOW/HORIZONTAL LEFT ZERO CLEARANCE CONVERSION KIT: RXGY-ZK

COMBUSTIBLE FLOOR BASE: RXGC-B17RXGC-B21RXGC-B24

[ ] Designates Metric Conversions

VENT TERMINATION KITS: =RXGY-E02: Vertical/Horizontal Concentric Vent Termination Kit 2" Pipe (US Only)

RXGY-E02A: Vertical/Horizontal Concentric Vent Termination Kit 2" Pipe (US & Canadian)

RXGY-E03: Vertical/Horizontal Concentric Vent Termination Kit 3" Pipe (US Only)

RXGY-E03A: Vertical/Horizontal Concentric Vent Termination Kit 3" Pipe (US & Canadian)

RXGY-G02: Direct Vent Furnace Side Wall Vent 2" or 3" (US Only)

RXGY-D05: Combustion Air Drain Kit 2"

RXGY-D06: Combustion Air Drain Kit 3"

NEUTRALIZER KIT: RXGY-A01 (Replacement Cartridge 54-22120-01)

EXTERNAL BOTTOM FILTER (UPFLOW/HORIZONTAL) RACK:RXGF-CB

EXTERNAL SIDE (UPFLOW) FILTER RACK: RXGF-CD

EXTERNAL (DOWNFLOW) FILTER RACK: RXGF-CC

INDOOR COIL CASINGSMODEL

NUMBER

RXBC-D17A1RXBC-D21A1RXBC-D21B1RXBC-D24A1

Page 9: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

Fujitsu General America, Inc. 9

Limited WarrantyFF***TS92 Series

GENERAL TERMS OF LIMITED WARRANTY*Fujitsu General America, Inc. will furnish a replacement forany part of this product which fails in normal use and servicewithin the applicable period stated, in accordance with theterms of the limited warranty.

*For complete details of the Limited and Conditional Warranties, includingapplicable terms and conditions, contact your local contractor or theManufacturer for a copy of the product warranty certificate.

Conditional Parts(Registration Required) ...............................Ten (10) Years

Heat Exchanger .........................................Limited Lifetime

Page 10: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

10 Fujitsu General America, Inc.

NotesFF***TS92 Series

Page 11: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

Fujitsu General America, Inc. 11

NotesFF***TS92 Series

Page 12: MULTI POSITION GAS FURNACE - fujitsu-general.com Fujitsu General America, Inc. Table of Contents FF***TS92 Series TABLE OF CONTENTS Standard & Optional Equipment .....3

Before proceeding with installation, referto installation instructions packagedwith each model, as well as complyingwith all Federal, State, Provincial, andLocal codes, regulations, and practices.

“In keeping with its policy of continuous progress and product improvement, the right is reserved to make changes without notice.”

PRINTED IN U.S.A. 4-17 QG FORM NO. GFJ-552 Supersedes Form No. ATZ-204