12
Monoblock Refrigeration Units for commercial cooling The perfect refrigeration capacity for all cooling requirements Chilled goods storage -5ºC to +12ºC Frozen goods storage -5ºC to -25ºC BERG BERG BERG BERGCOLD COLD COLD COLD ®

Monoblock Refrigeration Units - DEEC · Our Monoblock Refrigeration Units represent state-of-the-art, plug & play refrigeration technology, which have proven themselves in thousands

  • Upload
    phamtu

  • View
    273

  • Download
    1

Embed Size (px)

Citation preview

Monoblock Refrigeration Units for commercial cooling

The perfect refrigeration capacity for all cooling requirements

Chilled goods storage -5ºC to +12ºC

Frozen goods storage -5ºC to -25ºC

BERGBERGBERGBERGCOLDCOLDCOLDCOLD ®

2

BERGCOLD ®

Monoblock Refrigeration Units for commercial cooling Our Monoblock Refrigeration Units represent state-of-the-art, plug & play refrigeration technology, which have proven themselves in thousands of installations. During the design phase we made sure to use only high quality, commonly available components. Thanks to the modular design and the flexible, ultra-modern production facilities, these series products can be manufactured extremely precise at low cost. We can supply these integrated refrigeration units from stock.

Chilled goods storage -5ºC to +12ºC Plug & play „cellar freshness“ for businesses and homes Just like in a refrigerator, you can store goods – whether they be fruit, vegetables, meat, dairy products or drinks at different levels on shelving. The cold air circulating in the room will then cool all the food to a perfect temperature. Fruit and vegetables will stay crisp and fresh, mineral water, beer and wine can be stored at the perfect temperature for drinking.

Frozen goods storage -5ºC to -25ºC Low cost refrigeration to maintain freshness for weeks or even months The perfect refrigeration capacity for all freezing requirements BERGCOLD Monoblock Refrigeration Units are available from stock with cooling capacities ranging from 560 W to 22847 W for room sizes of up to 665 m3. This is enough even for short and long term food storage in stores, large restau-rants and food industry .

3

BERGCOLD ®

Monoblock Refrigeration Units for wall mounting

Cooling range Refrigerant

Unit type Refrigeration Capacity W 1)

Power Consumption W 1)

Cell content M³ 2)

Rated current A

Noise level dBA/1m 3)

Weight kg

NK600 H 700 535 8 2,9 55 45

NK900 H 860 610 11 3,3 57 50

NK1200 H 1180 885 18 4,8 59 55

NK1500 H 1440 985 23 5,3 61 56

NK2000 H 2000 1300 36 7,1 62 77

NK3000 H 3000 1930 60 10,5 68 82

-5ºC to +12ºC Refrigerant: R134a

Cooling range Refrigerant

Unit type Refrigeration Capacity W 1)

Power Consumption W 1)

Cell content M³ 2)

Rated current A

Noise level dBA/1m 3)

Weight kg

TK500 H 560 730 6 4 59 50

TK700 H 700 800 8 4,4 61 66

TK1000 H 1000 1080 15 5,9 65 72

TK1200 H 1400 1390 26 7,5 65 80

TK1500 H 1800 1930 36 10,5 66 95

-5ºC to –25ºC Refrigerant: R404A

The refrigeration unit is supplied ready for connection and installed in two recesses made in the cell wall. The supplied installation template provides assistance for making the recesses and for drilling the hole for the defrost water drain hose. The unit can be installed in cells with an insulation thickness of 70 to 120 mm.

1) Performance figures in an ambient temperature of +32ºC and air intake temperature at the cooler of +5ºC or -18ºC and normal walk-in conditions. The unit capacities were measured in accordance with DIN 8942. 2) The following marginal conditions were used to calculate the cell size: Standard cooling: Ambient cell temperature: 32ºC, insulation thickness: 70 mm (k=0.27 W/m2K), compressor operating cycle: 16 hours, goods feed rate: 30 kg/m2d, goods cooling: 15 k Extra-low temperature cooling: Ambient cell temperature: 32ºC, insulation thickness: 100 mm (k=0.19 W/m2K), compressor operating cycle: 18 hours, goods feed rate: 30 kg/m2d, goods cooling: 4 k 3) Measured when installed on the exterior of the cooling cell On request a remote control (Art. No. ...F) for unit types H and S can be supplied (special accessory). A winter controller is required for external temperatures below 10ºC (special accessory).

4

BERGCOLD ®

Monoblock units

Units: NK 600 H, 900, 1200 H, 1500 H TK 500 H

5

BERGCOLD ®

Monoblock units

Units: NK 2000 H - 3000 H TK 700 H - 1500 H

6

BERGCOLD ®

Monoblock Refrigeration Units for wall mounting

Cooling range Refrigerant

Unit type Refrigeration Capacity W 1)

Power Consumption W 1)

Cell content m³ 2)

Rated current A

Weight kg

-5ºC to +8ºC Refrigerant: R404A

PTM 054 5279 2473 72 5,4 167

PTM 068 6936 3388 100 8,7 187

PTM 080 8023 3361 120 8 202

PTM 110 9462 4403 145 10,4 308

PTM 140 12158 6074 194 15,4 325

PTM 200 16023 7321 265 17,5 358

PTM 300 19417 6490 358 22,87 620

PTM 370 23104 10590 432 24,6 650

Design

C

D

D

E

E

E

F

F

Cooling range Refrigerant

Unit type Refrigeration Capacity W 1)

Power Consumption W 1)

Cell content M³ 2)

Rated current A

Weight kg

-5ºC to –25ºC Refrigerant: R404A

PTL 034 4161 2871 63,8 5,6 182

PTL 060 4284 3150 67 8,4 187

PTL 080 5237 3800 90 9,1 202

PTL 130 7032 4840 137 12 351

PTL 180 9668 5530 216 12,7 368

PTL 200 10770 7370 249 18,6 409

PTL 260 13717 8810 342 20,8 412

PTL 350 18790 12080 517 29,8 690

PTL 450 22847 13880 665 33,1 720

Design

C

D

D

E

E

E

E

F

F

The refrigeration unit for wall mounting PT is supplied ready for connection and is simply pushed into a prepared opening in the cell wall. The dimensions of this opening are identical to those of the insulation element that is already installed on the rear of the refrigeration unit. The unit can be installed in cells with an insula-tion thickness of 70 to 150 mm.

1) Performance figures in an ambient temperature of +32ºC and air intake temperature at the cooler of +5ºC or -18ºC and normal walk-in conditions. The unit capacities were measured in accordance with DIN 8942. 2) The following marginal conditions were used to calculate the cell size: Standard cooling: Ambient cell temperature: 32ºC, insulation thickness: 70 mm (k=0.27 W/m2K), compressor operating cycle: 16 hours, goods feed rate: 30 kg/m2d, goods cooling: 15 k Extra-low temperature cooling: Ambient cell temperature: 32ºC, insulation thickness: 100 mm (k=0.19 W/m2K), compressor operating cycle: 18 hours, goods feed rate: 30 kg/m2d, goods cooling: 4 k On request a remote control (Art. No. ...F) for unit types H and S can be supplied (special accessory). A winter controller is required for external temperatures below 10ºC (special accessory).

7

BERGCOLD ®

Monoblock units: PTM + PTL

Design: C

Design: D

8

BERGCOLD ®

Monoblock units: PTM + PTL

Design: E

Design: F

1800

960

2000

1840

1150 1020

752

9

BERGCOLD ®

Monoblock Refrigeration Units for ceiling mounting

Cooling range Refrigerant

Unit type Refrigeration Capacity W 1)

Power Consumption W 1)

Cell content M³ 2)

Rated current A

Noise level dBA/1m 3)

Weight kg

NK600 D 630 540 7 2,9 53 51

NK900 D 820 600 10 3,3 55 60

NK1200 D 1140 830 16 4,5 57 65

NK1500 D 1420 930 22 5,1 59 66

NK2000 D 2180 1560 39 8 60 10

NK3000 D 2780 2000 55 10,3 66 118

-5ºC to +12ºC Refrigerant: R134a

Cooling range Refrigerant

Unit type Refrigeration Capacity W 1)

Power Consumption W 1)

Cell content M³ 2)

Rated current A

Noise level dBA/1m 3)

Weight kg

TK500 D 480 650 4 3,54 57 57

TK700 D 640 730 7 4 59 64

TK1000 D 950 1040 13 5,3 63 98

TK1200 D 1150 1300 18 6,6 63 99

TK1500 D 1620 2020 32 10,4 64 117

-5ºC to –25ºC Refrigerant: R404A

The refrigeration unit for ceiling mounting is supplied ready for con-nection and is simply pushed into a prepared opening in the cell cei-ling. The installation depth of the air cooler parts is 100 mm for stan-dard coolers and 120 mm for extra-low temperature coolers. The unit is controlled using a remote control designed for variable installation.

1) Performance figures in an ambient temperature of +32ºC and air intake temperature at the cooler of +5ºC or -18ºC and normal walk-in conditions. The unit capacities were measured in accordance with DIN 8942. 2) The following marginal conditions were used to calculate the cell size: Standard cooling: Ambient cell temperature: 32ºC, insulation thickness: 70 mm (k=0.27 W/m2K), compressor operating cycle: 16 hours, goods feed rate: 30 kg/m2d, goods cooling: 15 k Extra-low temperature cooling: Ambient cell temperature: 32ºC, insulation thickness: 100 mm (k=0.19 W/m2K), compressor operating cycle: 18 hours, goods feed rate: 30 kg/m2d, goods cooling: 4 k 3) Measured when installed on the exterior of the cooling cell On request a remote control (Art. No. ...F) for unit types H and S can be supplied (special accessory). A winter controller is required for external temperatures below 10ºC (special accessory).

10

BERGCOLD ®

Units: NK 2000D, 3000D TK 1000D, 1200D, 1500D

Monoblock ceiling units Units: NK 600D, 900D,1200D,1500D TK 500 D, 700D

11

BERGCOLD ®

Service around the clock We know exactly how expensive the failure of a machine or facility can be. Our customers have access to global high-tech service, both online and offline.

INTERCOM DEEC GmbH

Schachtweg 3 D-95659 Arzberg Germany

Pon.: +49 (0)9233/7156376 Fax: +49 (0)9233/7156377

E-Mail: [email protected] Internet: www.deec.de

BERGBERGBERGBERGCOLDCOLDCOLDCOLD ®