Model FMP 100 - 200 PROOFER

Page 2: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain
Page 3: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

MODEL FMP 100-200 PROOFER OPERATION AND SERVICE MANUAL

Table of contents

PAGE

1 Installation 1

2 Safety information 3

3 Features / Controls 4 4 Operating instructions 5 5 Technical 7

Parts / Electrical 9

Schematic 10

Friedrich Metal Products Co., Inc. 6204 Technology Drive

Browns Summit, NC 27214 (336) 375-3067

Page 4: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

INSTALLATION

SPECIAL NOTICES o Your Friedrich Proofer has been thoroughly tested and checked before shipping to your store.

Upon receipt of crated unit unpack carefully and inspect for damages. File any claims that may be required with the shipping company immediately. If necessary to replace damaged parts with new ones, contact FMP via phone(336)-375-3067 or FAX (336) 621-7901 to expedite shipment.

o The customer is responsible for providing and completing all the installation work necessary to

ensure the safe and proper operation of the Proofer. This includes but is not limited to complying with all local codes with respect to electrical work and plumbing hookups (inlet water line, water softener (if used), water filter (if used), and drain line).

o In addition all work must be done in strict compliance with plans and specifications provided

by Friedrich. Contact FMP in writing (FAX (336) 621-7901) for resolution of any matter arising out of interpretation of plans and/or specifications.

o Further, if installers determine that an installation cannot be accomplished in strict accordance

with plans and specifications, the customer must contact FMP in writing (FAX) to request a written authorization (FAX) to deviate from the original plans and specifications. Written authorizations from FMP to alter plans and specifications will be added to the customer's order file to preserve the equipment warranty. If a written authorization to alter plans and specifications is not in the customer's own file and not on file with FMP, the equipment warranty shall be deemed void.

*IMPORTANT*

o Any and all electrical, plumbing or other installation work not completed in strict accordance with FMP plans or specifications or interpretations provided in writing (FAX) will immediately void any and all warranties covering the Proofer.

1

Page 5: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

INSTALLATION REOUIREMENTS. a. Electrical Service - All FMP Proofers are ARL listed. Customers are responsible for complying with local electrical codes when installing Proofers

purchased through FMP. All Proofer models require isolated electrical service for operating the blower/control and heating systems.

o Refer to electrical schematic for requirements on specific models. b. Plumbing Facilities - All Proofer models require the following plumbing facilities to handle

the water needs of the humidity generating systems: o 1/4-inch water inlet line o 3/4-inch drain line(s) o Cold water inlet o An inlet water filter and/or water softener may be required in areas with known water

quality problems. NOTE Operation of the Proofer depends on the presence of some ions (i.e. iron), while scale forming ions (i.e. calcium)can be a problem. In areas where there are known water quality problems contact a local water treatment company for recommended filter/softener installations. 2-2. INSTALLATION DIAGRAMS. Figure 4-1 and 4-2 show where electrical service and plumbing facilities are to be connected to a Proofer being installed. The electrical lines shall be run and connected in strict compliance with local codes for 120 volt ac and 208/240 volt ac service. The plumbing shall also be installed and connected to be compliant with local codes. In addition the following plumbing installation techniques apply:

a. Use a 1/4-inch copper water pipe as the inlet water line to the Proofer water supply solenoid. Water pressure must be 20-30 psi (pounds per square inch). b. Use both a shut off valve and a disconnect fitting as part of the inlet line, installed as close to

the Proofer as practical. c. Use a 3/4-inch copper drain pipe connected between the Proofer drain(s) and an approved

drain source. Pitch the drain pipe downward (1-inch per foot) to achieve an efficient gravity drain. (A trough drain installed in front of the Proofer is highly recommended.)

2

Page 6: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

SAFETY INFORMATION 1. The frame of unit MUST be electrically grounded at all times. See "Installation -

electrical." FAILURE TO GROUND THIS UNIT MAY RESULT IN AN

ELECTRICAL SHOCK. 2. DO NOT use aluminum foil or any other protective material on inner liner surfaces or

food racks. 3. The proofing area MUST be kept clear and free of combustible materials, gasolines

and other flammable vapors and liquids. 4. DO NOT open service panel when unit is in operation, or leave open during

operation. 5. DO NOT allow unqualified personnel to perform service work or adjustments on this

unit. To do so will VOID warranty and could result in a hazardous condition.

6. Be sure any new employees, who might operate the unit, are instructed on operation and safety information prior to operating the unit. 7. Keep this instruction manual for reference.

3

Page 7: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

Model FMP 100 - 200 PROOFER

PROOFER CONTROLS AND COMPONENTS

1. TEMPERATURE CONTROL - To be set between 90 and 110 degrees F. depending on local conditions and product to be pr oofed.2. TEMPERATURE INDICATOR - Light, to show heating elements are operating to b ring

temperature in proofer to set value. Extinguishes when set value is o btained.3. POWER SWITCH - To be set to "On" position for proofing. Built in power indicator lights

to show 120 volt AC power is applied to the blower and/or contro l circuit.4. HUMIDITY CONTROL - To be set between 60 and 70% RH depending on l ocal

conditions and product to be proo fed.5. HUMIDITY INDICATOR - Light, to show system is operating to bring humidity in proofer

to set value. Extinguishes when set value is ob tained.

12

3

5

4

4

Page 8: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

OPERATING INSTRUCTIONS REFER TO PAGES ON PROOFER CONTROLS AND COMPONENTS AS NEEDED FOR DETAILS ON LOCATION AND FUNCTION OF FEATURES. STEP 1 - Set power switch to “On” position. Listen for and observe the following:

a. Fan starts and runs b. Power indicator (built into switch) lights red.

STEP 2 - Depending on local conditions and products to be proofed, set humidity and temperature controls as follows: a. Set humidity control to recommended setting between 60 and 70% RH. Observe that humidity indicator lights up, showing that system is operating to bring humidity in

proofer to set value. When first powered up, control displays actual humidity. 1. Press <SET> button….will display “SP” 2. Press <SET> button again to display or set desired humidity. 3. Press <UP> or <DOWN> arrow buttons to set desired humidity. 4. Press <SET> button again to initiate change….will display “SP” 5. Press <SET> and <DOWN> arrow button at same time or wait one minute to

quit programming and display actual humidity. b. Set temperature control to recommended setting between 90 and 110 degrees F.

Observe that temperature indicator lights up, showing that system is operating to bring temperature in proofer to set value.

STEP 3 - Wait 20 - 30 minutes for humidity and temperature inside proofer to stabilize. NOTES:

1. If humidity is set too high, condensation inside proofer may be excessive and water will accumulate on floor.

2. Frozen dough products must be completely thawed before proofing. 3. Humidity does not cause dough to rise, but does add moisture to prevent drying. 4. For “crusty bread” products, texture of proofed dough should be soft and pliable to

the touch, not sticky or dry. If the proofed product goes into the oven sticky or dry, no matter how much steam is added during baking, a proper durable crust will not form.

STEP 4 - Load product into proofer and proceed with proofing jobs for the day. NOTE:

When loading and unloading product, keeping “Door Open” time as short as possible will result in faster proofing and energy savings.

STEP 5 - After unloading last product from proofer at end of work day, set power switch to “Off” position.

CLEANING

1. At end of workday wipe down inside and outside of proofer. 2. Once a week clean outside of proofer with non-abrasive stainless steel cleaner.

Page 9: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

The points of connection for electrical service and plumbing facilities are shown for each Proofer model in the installation diagrams on page 7 and 8. The installation diagrams also give details of the physical features of each Proofer model for use by installation planners and installers. These physical features include dimensional data, uncrated weights, and clearances required for running and connecting electrical and plumbing lines. Use the installation diagram for the Proofer model as a guide to installing the unit.

6

Page 10: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

53.3

6034

.555

75.0

0085.5

72

1.500

PO

WE

R R

EQ

UIR

EM

EN

TS12

0V 1

PH

. 15

AM

P24

0V 1

PH

. 15

AM

PW

EIG

HT

450

LBS

.U

NIT

REQ

UIR

ES A

FLA

TA

ND

LE

VE

L FL

OO

R

DO

OR

OP

EN

ING

23 X

75

BA

KE

RY

PR

OO

FE

RM

OD

EL

FMP

200

-909

-27/

8O F

OR

110V

ELEC

TRIC

SER

VICE

7/8O

FOR

220

VEL

ECTR

IC S

ERVI

CE1/

4" N

PT W

ATER

SU

PPLY

HI T

EMP

LIM

IT R

ESET

3/4"

NPT

DRAI

N

23.18

0CL

EAR

DOOR

23.18

0CL

EAR

DOOR

37.3

14

31.4

28CL

EAR

INSI

DE

7

Page 11: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

Tolerences : .XX = u.062 .XXX = u.031 X v = u.5

v U

nless otherwise noted

.125

Mod.

Dw

g.#R

ev.

Part

Where U

sed

Dr by

Model

Tape #

Scale

B/A

Mat.

Drn

# Req.

Makes

1

Qty

NO

TE : ALL D

IMENSIO

NS TO O

UTSIDE

OF BEN

DS / MA

TERIA

L UN

LESS O

THERW

ISE NOTED

.

1File #

- --- --

3

12/18/20087/2/2012

910 PROOFER ASSEMBLY

910 -1000ASSEM

BLY.dft

FMP 910 PROOFER

GBNS

A

45.500

42.883CLEARINSIDE

32.000

29.000CLEARINSIDE

75.0CLEARINSIDE

47.085 1/2" NPTDRAIN

HI TEMP LIM

IT RESET

1/4" NPT WATER SU

PPLY@

45 PSI (MIN)

7/8O FOR 220V

ELECTRIC SERVICE

7/8O FOR 110V

ELECTRIC SERVICE

BAK

ERY PR

OO

FERM

OD

EL FMP 200-910

PO

WE

R R

EQ

UIR

EM

EN

TS120V

1 PH

. 15 AM

P240V

1 PH

. 15 AM

PW

EIG

HT 450 LB

S.

UN

IT RE

QU

IRE

S A

FLAT

AN

D LE

VE

L FLOO

R

85.741

Page 12: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

M

ETA

L P

RO

DU

CTS

7/22

/201

1pa

ge 5

-2 P

AR

TSD

igita

l.vsd

FMP

100

/ 200

ELEC

TRIC

PA

NEL

Q

TY

1. S

WIT

CH

, PO

WER

(W/ I

ND

ICAT

ION

) 1

2.

CO

NTR

OL,

TE

MPE

RAT

UR

E 1

3.

LIG

HT,

IND

ICA

TOR

(TEM

PER

ATU

RE

) 1

4.

CO

NTR

OL,

HU

MID

ITY

1

5. L

IGH

T, IN

DIC

ATO

R (H

UM

IDIT

Y)

1

6. H

IGH

TE

MP

ERAT

UR

E L

IMIT

(MAN

UAL

RE

SET)

1

7.

TER

MIN

AL

BLO

CK

(120

VO

LT)

1

8. T

ERM

INA

L BL

OC

K (2

40 V

OLT

) 1

9.

GR

OU

ND

ING

LU

G

1

10. V

ALV

E, H

UM

IDIT

Y 1

11

. REL

AY,

HE

AT

1

12. H

EATE

R

1

13. B

LOW

ER

1

PR

OO

FER TE

MPE

RA

TURE

HU

MID

ITY

POW

ER

53

42

1

67

89

10

11

12

4

51

2

13

3

9

Page 13: Model FMP 100 - 200 PROOFERgreerequip.com/wp-content/uploads/2013/06/FMP-200-Book-specs.pdfContact FMP in writing (FAX (336) 621-7901) for resolution of any matter ... Pitch the drain

X1

L1L2

X2

10

48

26

HEATER

MH

UM

IDIT

YS

OLE

NO

ID

HU

MID

ITY

CO

NTR

OL

10

911

23

7

LL

PO

WE

RS

WIT

CH

TEM

PIN

D. L

IGH

TH

UM

IDIT

YIN

D. L

IGH

T

TEM

P.

CO

NTR

OL

HIG

H T

EM

P. L

IMIT

(S)

N/C

BLO

WE

R(S

)

DR

AW

N03

/24/

11D

raw

ing

1

FMP-

100

/ FM

P-20

0

Ele

ctric

al S

chem

aticM

ETA

L PR

OD

UC

TSP

roof

er

DW

G.#

100

-1

SE

RIA

L N

O.

022-

Rev

. # C

L

120

V1

phas

e 15

am

p24

0V. 1

pha

seFM

P-1

00 /2

00 1

5 am

p Rel

ay

FIG. 5-1

GG

roun

d

78

120

V

10