Range of macerators and pumps to improve your home
TECHNICAL DATA
Which product to use for my application? p. 3
Sanisan 1 + operation “Sanisan discharge” p. 4 - 5
Sanisan 2 p. 6 - 7
Sanisan 3 p. 8 - 9
Sanisan 4 p. 10 - 11
Alizé p. 12
Sanisan Condens p. 13 - 14
Installation: 10 Golden Rules p. 15 - 16
Range of macerators and pumps to improve your home
INDEX
2
� TO CREATE OR UPGRADE A BATHROOM...
Range of macerators and pumps to improve your home
3
Which product to use for my application?
� TO CREATE OR UPGRADE A KITCHEN OR LAUNDRY ROOM...
4
426 m m
268 mm
290,5 mm
183,6 mm
235 m m
185 m m
A macerator to install a WC almostanywhere, no pre-equipped with
a pipeline of 100mm.
Range of macerators and pumps to improve your home
5
2b
51
2a
57
52
6427
16
6a
4
5c5b5a
50
38
18
49b
48
49a
14
39
53
43
44
17
42
41a
40a
40b
41b
15
6b
24
34
1
56 35
55
12
11
20
13
9
10a
28a
20b
25
8
7c
2960 28b28b: : TECHNICAL DATA ::
� Vertical discharge Up to 1 m� Horizontal discharge* Up to 20 m� Discharge 22-32 mm� Grinding system Knife� Power 220/240V 50Hz� Power consumption 550W� Index of protection IP44
* with a slope of 3%
Range of macerators and pumps to improve your home
6
426 m m
268 mm
290,5 mm
183,6 mm
235 m m
185 m m
A macerator to evacuate the wastefrom a traditional toilet and a wash
basin
Range of macerators and pumps to improve your home
: : TECHNICAL DATA ::
� Vertical discharge Up to 4 m� Horizontal discharge* Up to 40 m� Upper inlet 1x40mm� Discharge 22-32 mm� Grinding system Knife� Power 220/240V 50Hz� Power consumption 720W� Index of protection IP44
* with a slope of 3%7
2b
12
17
11
20
13
3
6a
51
55
45c5b5a
57
52
50
38
18
49b
48
49a
14
39
53
43
44
16
42
41a
40a
40b
41b
15
6b
24
9
10a
22
2a
64
2754
34
1
5635
28
7c
20b
8
25 212960 28b28b
Range of macerators and pumps to improve your home
8
426 m m
268 mm
290,5 mm
183,6 mm
32,5 mm
235 m m
185 m m
A powerful macerator that allowsthe installation of a complete
bathroom with a shower
Range of macerators and pumps to improve your home
9
2b
12
17
11
20
13
3
6a
51
55
45c5b5a
57
52
50
38
18
49b
48
49a
14
39
53
43
44
16
42
41a
40a
40b
41b
15
6b
24
9
10a
22
2a
64
2754
34
1
5635
37
33a 33b 32
28
7c
20b
8
25 21
31
2960 28b28b
30a 30b
: : TECHNICAL DATA ::
� Vertical discharge Up to 4 m� Horizontal discharge* Up to 40 m� Upper inlet 1x40mm� Side inlets 2x40mm� Discharge 22-32 mm� Grinding system Knife� Power 220/240V 50Hz� Power consumption 550W� Index of protection IP44
* with a slope of 3%
Range of macerators and pumps to improve your home
10
With this pump, you can create a newkitchen or laundry room in the basement: it
can discharge water with higher temperatures
Range of macerators and pumps to improve your home
11
99
1313
33
6a6a
6b6b
5151
5757
5252
5050
56563737
11
323233a33a 33b33b
2b2b
88
2020
1111
2222
1010
1616
1818
49b49b
4848
49a49a
1414
3939
4343
1717
4242
41a41a
40a40a
40b40b
41b41b
1515
3838
2a2a 2525 28282828
6464
2727
2424
5454 2121
5050
5454
3131
: : TECHNICAL DATA ::
� Vertical discharge Up to 5 m� Horizontal discharge* Up to 50 m� Upper inlet 1x40mm� Side inlets 2x40mm� Discharge 32-40 mm� Working temperature 40°C� Maximum temperature (short periods) 40°C� Power 220/240V 50Hz� Power consumption 350W� Index of protection IP44
* with a slope of 3%
Range of macerators and pumps to improve your home
12
The space-saving: a macerator built-in inside the belly of the bowl that alsodischarges water from a wash basin
: : TECHNICAL DATA ::
� Vertical discharge Up to 3 m� Horizontal discharge* Up to 30 m� Discharge 40 mm� Grinding system Knife� Power 220/240V 50Hz� Power consumption 500W
* with a slope of 3%
Range of macerators and pumps to improve your home
13
SANISAN CONDENS is used for disposing of thecondensate from condensing boilers and other water
producing equipment such as air conditioners,dehumidifiers etc.
Range of macerators and pumps to improve your home
CONDENS
14
: : TECHNICAL DATA ::
� Vertical discharge Up to 4,5 m� Discharge 8 mm� Working temperature 35°C� Maximum temperature (short periods) 80°C� Power 220/240V 50Hz� Power consumption 60W� Index of protection IP20
Range of macerators and pumps to improve your home
15
TEN GOLDEN RULES FOR CORRECT INSTALLATION
min 1 %
All horizontal pipesshould have a mi-nimum fall of1:100.
Bends should besmooth/long ra-dius, not tight el-bows.(Examplesof copper andplastic shown.)
Pipes entering themacerator shouldhave a gravity fall of1:33.
Where the pipework fallsto a floor lower for exam-ple, fit an air admittancevalve at the highestpoint capable of with-standing 10psi pressure,or increase pipe sizecoming down to ‘break’syphon.
If a vertical run is nee-ded, this should be atthe start of the run(within 30cm of theunit) and from thehigh point there mustbe a minimum fall of1:100 (see rule 1).
Air admittance valve
Range of macerators and pumps to improve your home
16
Each discharge pipeshould run separatelyto the soil pipe. Ifwastes are combi-ned, it can only beinto a larger pipe,which is on a gravityfall.
Since many close cou-pled WC suites do nothave the space bet-ween the WC pan spi-got and the wall, youmay have to batten thecistern off the wallto make room for themacerator.
Position the macera-tor behind the toiletnot underneath it.
We recommend for youto use biodegradablesdetergents for thewashing machine anddishwasher; and alsouse a descaler in orderto keep calcium out ofthe system.
The unit should beeasily accessibleand removable inthe event ofmaintenance beingrequired. If boxed in,the boxing should beeasily removed. Anyextension betweenthe WC pan spigotand wall should notexceed 150mm.
battening
panels
Range of macerators and pumps to improve your home