    Range of macerators and pumps to improve your home

    INDEX

    2

  • � TO CREATE OR UPGRADE A BATHROOM...

    Range of macerators and pumps to improve your home

    3

    Which product to use for my application?

    � TO CREATE OR UPGRADE A KITCHEN OR LAUNDRY ROOM...

  • 4

    426 m m

    268 mm

    290,5 mm

    183,6 mm

    235 m m

    185 m m

    A macerator to install a WC almostanywhere, no pre-equipped with

    a pipeline of 100mm.

    Range of macerators and pumps to improve your home

  • 5

    2b

    51

    2a

    57

    52

    6427

    16

    6a

    4

    5c5b5a

    50

    38

    18

    49b

    48

    49a

    14

    39

    53

    43

    44

    17

    42

    41a

    40a

    40b

    41b

    15

    6b

    24

    34

    1

    56 35

    55

    12

    11

    20

    13

    9

    10a

    28a

    20b

    25

    8

    7c

    2960 28b28b: : TECHNICAL DATA ::

    � Vertical discharge Up to 1 m� Horizontal discharge* Up to 20 m� Discharge 22-32 mm� Grinding system Knife� Power 220/240V 50Hz� Power consumption 550W� Index of protection IP44

    * with a slope of 3%

    Range of macerators and pumps to improve your home

  • 6

    426 m m

    268 mm

    290,5 mm

    183,6 mm

    235 m m

    185 m m

    A macerator to evacuate the wastefrom a traditional toilet and a wash

    basin

    Range of macerators and pumps to improve your home

  • : : TECHNICAL DATA ::

    � Vertical discharge Up to 4 m� Horizontal discharge* Up to 40 m� Upper inlet 1x40mm� Discharge 22-32 mm� Grinding system Knife� Power 220/240V 50Hz� Power consumption 720W� Index of protection IP44

    * with a slope of 3%7

    2b

    12

    17

    11

    20

    13

    3

    6a

    51

    55

    45c5b5a

    57

    52

    50

    38

    18

    49b

    48

    49a

    14

    39

    53

    43

    44

    16

    42

    41a

    40a

    40b

    41b

    15

    6b

    24

    9

    10a

    22

    2a

    64

    2754

    34

    1

    5635

    28

    7c

    20b

    8

    25 212960 28b28b

    Range of macerators and pumps to improve your home

  • 8

    426 m m

    268 mm

    290,5 mm

    183,6 mm

    32,5 mm

    235 m m

    185 m m

    A powerful macerator that allowsthe installation of a complete

    bathroom with a shower

    Range of macerators and pumps to improve your home

  • 9

    2b

    12

    17

    11

    20

    13

    3

    6a

    51

    55

    45c5b5a

    57

    52

    50

    38

    18

    49b

    48

    49a

    14

    39

    53

    43

    44

    16

    42

    41a

    40a

    40b

    41b

    15

    6b

    24

    9

    10a

    22

    2a

    64

    2754

    34

    1

    5635

    37

    33a 33b 32

    28

    7c

    20b

    8

    25 21

    31

    2960 28b28b

    30a 30b

    : : TECHNICAL DATA ::

    � Vertical discharge Up to 4 m� Horizontal discharge* Up to 40 m� Upper inlet 1x40mm� Side inlets 2x40mm� Discharge 22-32 mm� Grinding system Knife� Power 220/240V 50Hz� Power consumption 550W� Index of protection IP44

    * with a slope of 3%

    Range of macerators and pumps to improve your home

  • 10

    With this pump, you can create a newkitchen or laundry room in the basement: it

    can discharge water with higher temperatures

    Range of macerators and pumps to improve your home

  • 11

    99

    1313

    33

    6a6a

    6b6b

    5151

    5757

    5252

    5050

    56563737

    11

    323233a33a 33b33b

    2b2b

    88

    2020

    1111

    2222

    1010

    1616

    1818

    49b49b

    4848

    49a49a

    1414

    3939

    4343

    1717

    4242

    41a41a

    40a40a

    40b40b

    41b41b

    1515

    3838

    2a2a 2525 28282828

    6464

    2727

    2424

    5454 2121

    5050

    5454

    3131

    : : TECHNICAL DATA ::

    � Vertical discharge Up to 5 m� Horizontal discharge* Up to 50 m� Upper inlet 1x40mm� Side inlets 2x40mm� Discharge 32-40 mm� Working temperature 40°C� Maximum temperature (short periods) 40°C� Power 220/240V 50Hz� Power consumption 350W� Index of protection IP44

    * with a slope of 3%

    Range of macerators and pumps to improve your home

  • 12

    The space-saving: a macerator built-in inside the belly of the bowl that alsodischarges water from a wash basin

    : : TECHNICAL DATA ::

    � Vertical discharge Up to 3 m� Horizontal discharge* Up to 30 m� Discharge 40 mm� Grinding system Knife� Power 220/240V 50Hz� Power consumption 500W

    * with a slope of 3%

    Range of macerators and pumps to improve your home

  • 13

    SANISAN CONDENS is used for disposing of thecondensate from condensing boilers and other water

    producing equipment such as air conditioners,dehumidifiers etc.

    Range of macerators and pumps to improve your home

    CONDENS

  • 14

    : : TECHNICAL DATA ::

    � Vertical discharge Up to 4,5 m� Discharge 8 mm� Working temperature 35°C� Maximum temperature (short periods) 80°C� Power 220/240V 50Hz� Power consumption 60W� Index of protection IP20

    Range of macerators and pumps to improve your home

  • 15

    TEN GOLDEN RULES FOR CORRECT INSTALLATION

    min 1 %

    All horizontal pipesshould have a mi-nimum fall of1:100.

    Bends should besmooth/long ra-dius, not tight el-bows.(Examplesof copper andplastic shown.)

    Pipes entering themacerator shouldhave a gravity fall of1:33.

    Where the pipework fallsto a floor lower for exam-ple, fit an air admittancevalve at the highestpoint capable of with-standing 10psi pressure,or increase pipe sizecoming down to ‘break’syphon.

    If a vertical run is nee-ded, this should be atthe start of the run(within 30cm of theunit) and from thehigh point there mustbe a minimum fall of1:100 (see rule 1).

    Air admittance valve

    Range of macerators and pumps to improve your home

  • 16

    Each discharge pipeshould run separatelyto the soil pipe. Ifwastes are combi-ned, it can only beinto a larger pipe,which is on a gravityfall.

    Since many close cou-pled WC suites do nothave the space bet-ween the WC pan spi-got and the wall, youmay have to batten thecistern off the wallto make room for themacerator.

    Position the macera-tor behind the toiletnot underneath it.

    We recommend for youto use biodegradablesdetergents for thewashing machine anddishwasher; and alsouse a descaler in orderto keep calcium out ofthe system.

    The unit should beeasily accessibleand removable inthe event ofmaintenance beingrequired. If boxed in,the boxing should beeasily removed. Anyextension betweenthe WC pan spigotand wall should notexceed 150mm.

    battening

    panels

    Range of macerators and pumps to improve your home