30
Meter/Service Line Inspections FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP [email protected]

Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP [email protected]

Embed Size (px)

Citation preview

Page 1: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Meter/Service Line InspectionsFECA Engineers Conference

June 11, 2013

R. Corey Parr, [email protected]

Page 2: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Safety Company meeting the insurance needs of our Members

FL 5 yr. Public Contacts = 42 $ 740,323

LCC for FL

2013 = $94,827, 9yr. Total = $607,973

5 yr. PCC = 42 $ 740,323

Page 3: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Why am I here?

Loss prevention Improve our position in litigation Discuss inspection practices of

automated metering systems Improve reliability

Page 4: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

The National Electric Safety Code

Duty to protect the publicResponsibility of the

utilities Highest degree of care

Mandated by the court

Page 5: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

AMR/AMI Systems

Positives = real time data, enhanced member service, outage management, reduced vehicle accidents & member property damage

Negatives = loss of documented eyes in the field

Page 6: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Related Claims Trends

Service drop claims that are ROW related

1. Loss of appliances

2. House fires

3. Contact with low service

Page 7: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Inspection Cycles

Poles 10 yr. Overhead line 5 yr. Underground 3 yr. Meter/Sevice 1-2 yr.

Page 8: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Service Line Insp.

General Condition

Clearance from the ground

Clearance from trees

Clearance from Structures

Weatherhead condition

Pole condition

Page 9: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 10: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 11: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 12: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 13: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 14: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 15: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 16: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 17: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 18: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Point of Attachment Look at the drip loop for:

Wires separated / couple of inches apartConnectors have tape covering them or either

plastic connector coversStrange wiring/Tampering

Look for damaged / bent mast pipes

Page 19: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 20: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 21: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 22: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Meters/Meter Bases

Exposed Wires

Check Meter Seal to be in place and

not cut

Uncovered Bases

Check CT/multiplier match

Page 23: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 24: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 25: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 26: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Exposed wiring – Customer’s disconnect

26

Page 27: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com
Page 28: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Meter Data

How long do you keep data Do you have a protocol

Page 29: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Summary

Duty to identify, report and repair hazards

Documentation of Inspection program Prioritize for repair Save lives, injuries and money

Page 30: Meter/Service Line Inspection s FECA Engineers Conference June 11, 2013 R. Corey Parr, CLCP cparr@federatedrural.com

Providing Market Stability, Service Excellence and

Safety Since 1959

Thank You