28
Member of the Integrated Metering Technologies AGRICULTURE Products Catalog METERS AMR/AMI CONTROL

METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

Member of the

Integrated Meter ing Technologies

AGRICULTURE P r o d u c t s C a t a l o g

METERS AMR/AMI CONTROL

Page 2: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

ARAD LTD.Arad Ltd. is a world leader in the field of water metering. The company designs, develops, manufactures, sells and supports its cutting edge water meters to domestic, waterworks, irrigation and water management companies around the world.

Millions of Arad’s water meters are installed worldwide and the company manufactures some 500,000 units a year, which had made it into one of the largest companies in the global water measuring industry.

Arad Ltd. has an in-house molding and injection manufacturing plant and operates a sophisticated testing and quality control bench, which examines each water meter separately.

Established in 1941, Arad Ltd. is based within the UNESCO biosphere reserve of Israel’s Ramat Menashe. According to the UN organization, the area “encompasses a mosaic of ecological systems that represent the Mediterranean Basin’s version of the global evergreen sclerophyllous forests, woodlands and scrub ecosystem types.”

All of the company’s polymeric ingredients are recyclable and its carbon footprint is carefully considered.

All of Arad’s products meet world standards of quality and performance, including ISO and AWWA standards. Its system is certified ISO 9001:2000, ISO 14000, ISO 18001, ISO 17025 and its products hold the CE mark. Every system is individually tested and inspected to ensure it meets the highest quality requirements.

Arad Ltd. is a member of the Arad Group.

A world leader in the field of water measurement solutions and services, the Arad Group specializes in designing, developing and manufacturing high quality meters, automatic meter reading (AMR) and advanced metering infrastructure (AMI) systems and advanced MDM systems and technologies.

Arad Group's patented solutions and products are specifically designed to meet the needs of utilities, waterworks companies and agriculture and are aimed at reducing water waste, improving overall water metering management capabilities and saving money.

Arad Group offers its clients a fully integrated source for complete water metering management and control systems. The company’s solutions, which set new standards for accuracy, performance and reliability, offer the following advantages: • Improving a utility’s financial, operational and customer care performance• Exact measurement• Automated and remote water reading• Real-time information availability • Precise control and management

Arad Group has a proven reputation for quality and precision in measuring, reading, collecting, transmitting and managing data from water metering to interacting with most billing systems, offering its clients the world’s most advanced water AMR and AMI solutions.

Today the Arad Group is comprised of five specialized divisions operating on four different continents and serving utility and water companies in more than sixty countries.

Divisions include:

Arad Ltd Arad Technologies Master Meter Contazara Arad China

Publicly traded on the Tel Aviv Stock Exchange (TASE) since 2004, Arad leverages Israel’s world-renowned technological skills, proven expertise in managing scarce water resources with Arad’s vast experience and professionalism.

With annual revenues exceeding $130 million, Arad Group has shown double-digit growth in each of last ten years from the sale of water measurement systems. Millions of its water meters are installed worldwide and the company has already sold more than three million smart meters, turning it into a world leader in advanced measuring solutions.

In order to maintain its leading position, the Arad Group is committed to investing a large proportion of its revenues in R&D each year, and to ensuring that its customers benefit from the most advanced solutions available in the market.

METERS AMR/AMI CONTROL

Page 3: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

Content

Irrigation & Agriculture Water Meters

WMR 2

IRT 4

Hydrometer

BM-BMA 6

DOSE-O-MAT Automatic Metering Valve

K-KB 8

KBJ 10

Plastic Fertilizer Meter

SF 12

KD 14

PB 16

Pilot Valves

PC 18

FC 19

Register output options

Electrical Output Versions 20

Warranty 24

Page 4: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 2 |

Agriculture

Irrigation & Agriculture Water MetersModel WMR

Maximum Working Pressure 16 bar

Maximum Liquid Temperature 55°C

Body Iron, polyester coated

Connection 2” BSP coupling

Technical Specifications

WMR type dial

The ample space around the core of the in-line helical axial turbine allows foreign matter to pass through the meter without clogging.

• Applications For main supply lines, agriculture and industry

• Available Sizes 2” (50mm)

• Standards EEC (based on ISO 4064:1993)

Features:• Minimum head loss• High accuracy• Hermetically sealed register with glass lens• Optional electrical output: EV (volume),

EF (rate of flow) or DIALOG• Not sensitive to dirt

Page 5: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 3 |

Agriculture

DimensionsModel WMR

Nominal size(mm) 50

(inch) 2

L - Length without couplings (mm) 200

H - Height (mm) 98

h - Height (mm) 40

Weight (kg) 2.3

Weight with couplings (kg) 3.7

Performance data:Model WMR

Qmax Maximum flowrate(m3/h)

QnISO 4064(m3/h)

QnNominal Flowrate (m3/h)

QtTransitional

Flowrate(m3/h)

QminMinimum Flowrate (m3/h)

Starting Flow

(m3/h)

Maximumregistercapacity

(m3)

Smallestreadable

unit(liter)

Accuracy between

Qmax & Qt

Accuracy between

Qt & Qmin Nominal size

(mm) (inch)

50 2 40 15 20 2 0.45 0.15 106 1 ±2% ±5%

Installation Requirements• The water meter may be installed in any position. For non-horizontal position the flow shall be upwards• The meter shall be full of water while operating• Prior to installation of a meter the pipeline shall be thoroughly flushed• Straight pipe section of the same diameter D as the meter, having lengths of 10D and 5D shall be installed

upstream and downstream of the meter respectively

Head Loss Curve

Page 6: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 4 |

Agriculture

Irrigation & Agriculture Water MetersModel IRT

Maximum Working Pressure 16 bar

Maximum Liquid Temperature 60°C

Body Cast iron, polyester coated

Connection Flanges according to ISO, BS 10, ANSI 150 or others

Technical Specifications

Special design with free water passage allows measurement of water with high contents of impurities.

• Applications Irrigation and sewerage metering

• Available Sizes 3” - 10” (80mm - 250mm)

Features:• Negligible head loss • Simple maintenance• Field replaceable measuring unit• Hermetically sealed register with glass lens• Bearings are constantly flushed during operation to eliminate

deposit of solids• Optional electrical output: EV (Volume) or EF (Rate of Flow)• Compatible with Dialog automatic reading system

IRT type dial

Page 7: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 5 |

Agriculture

Model

Nominal size(mm) 80 100 150 200 250

(inch) 3 4 6 8 10

L - Length without couplings (mm) 230 250 300 350 400

B - Width (mm) 240 260 310 315 438

H - Height (mm) 90 110 129 160 258

h - Height (mm) 16.5 19 32 45 55.5

Weight (kg) 15.5 19 35 47 75

Dimensions

Performance data:

Model IRT

Qmax Maximum flowrate(m3/h)

QnNominal Flowrate (m3/h)

QtTransitional

Flowrate(m3/h)

QminMinimum Flowrate (m3/h)

Maximumregistercapacity

(m3)

Smallestreadable

unit(liter)

Accuracy between

Qmax & Qt

Accuracy between

Qt & Qmin Nominal size

(mm) (inch)

80 3 150 90 10 5 107 10

±2% ±5%

100 4 250 125 11 7 107 10

150 6 500 250 15 10 107 10

200 8 900 450 30 18 107 10

250 10 1400 750 70 20 108 100

• The meter can be installed in any position (horizontal, vertical or inclined)• The meter must be always full of water while operating• Prior to the installation of a new meter, the pipeline must be flushed out• Straight pipe section of the same diameter D as the meter, having length of 10D and 5D shall be installed

upstream and downstream of the meter respectively

Installation Requirements

Head Loss Curve

Page 8: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 6 |

Agriculture

HydrometerModel BM-BMA

Description• The hydrometer combines a water meter and a hydraulic valve in a single

unit• The valve is double-chambered and is especially designed for high-

pressure operation• Pilot valves and solenoid valves enable remote and automatic

transmission of hydraulic commands to the hydrometer• The impeller is the only moving part in contact with the water• The meter contains a rotating leakage indicator as well as a totalizer

that displays cumulative volume• The meter electronically transmits flow data to the remote control

computer• The hydrometer is available in globe type and angle type models in

a variety of sizes

• ApplicationsThe BM/BMA hydrometers series are designed for remote control irrigation and for industrial applications. The hydrometer is especially suited for automated operation. The hydrometer may be used in a variety of pressure and flow regulation applications such as:• Pressure sustaining & reducing• Flow regulation• Combined pressure and flow regulation• Dual stage operation

• Available SizesBM - Globe type: 11⁄ 2, 2”, 3”, 4”, 6”, 8”BMA - Angle type: 2”, 3”, 4”, 6”, 8”

• StandardEEC, ISO 4064

Features:• Integrated design minimizes installation space. • Specifically designed for use in automated remote control environments• Wide variety of flow and pressure regulation options• Double-chambered hydraulic valve designed for high-pressure operation • Rugged, heavy-duty construction• Hermetically sealed register• Low loss of head• Wide range of sizes - suitable for virtually any application

Technical Specifications:Maximum Working Pressure

16 bar

Body Cast iron, polyester coatedReinforced natural rubber valve diaphragm.

Connection Flanges: AWWA, ISO, BS, other upon requestThreaded: Male BSP 11⁄ 2”-2”

Female BSPT or NPT 2”

Page 9: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 7 |

Agriculture

Dimensions

Model BM-Globe type BMA-Angle type

Nominal size(mm) 40 50 80 100 150 200 50 80 100 150 200

(inch) 1 1⁄ 2 2 3 4 6 8 2 3 4 6 8

L - Length (mm) 160 190 285 325 500 600 158 3 277 440 525

H - Height (mm) 262 330 420 435 645 765 350 243 450 645 675

h - (mm) - - - - - - 122 430 176 300 280

A - (mm) - - - - - - 96 140 162 250 300

B - Width (mm) 120 120 205 230 380 450 120 140 230 380 450

Weight (kg) 4.5 6.5 24.5 30.5 120 150 3.3 21 29.5 111 140

Weight with couplings (kg) 5.5 8 - - - - 47 - - - -

Performance dataModel

BM/BMAQmax

Maximum flowrate(m3/h)

QnNominal Flowrate

(m3/h)

QtTransitional

Flowrate (m3/h)

QminMinimum Flowrate (m3/h)

Minimum register capacity (m3/h)

Minimum register capacity

(liter)

Accuracy between

Qmax & Qt

Accuracy between

Qt & Qmin Nominal size

(mm) (inch)

40 1 1⁄ 2 30 20 1.3 0.8 106 1

±2% ±5%

50 2 50 30 3 0.45 106 1

80 3 130 65 8 1.2 106 1

100 4 200 100 12 1.8 107 10

150 6 300 150 30 4.5 107 10

200 8 540 270 50 7.5 107 10

Installation Requirements• The hydrometer can be installed in any position (horizontal, vertical or inclined)• The meter must be always full of water while operating• Prior to the installation of a new meter, the pipeline must be flushed out

A

h

Electrical output

Available Outputs(m3/pulse)

1 1⁄ 2” 2” 3” 4” 6” 8”

0.01 ● ● ●

0.1 ● ● ● ● ● ●

1 ● ● ● ● ● ●

10 ● ● ●

Head Loss Curve

Page 10: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 8 |

Agriculture

DOSE-O-MAT l Automatic Metering ValveModel K/KA, KB/KBA

Maximum Working Temperature

60°C

Body K 3/4” - 1” plastic All other models - cast iron

Connection K 3/4” - 3/4” BSPT male thread K 1” - 1 BSPT male thread K/KB 11/2” - 11/2” male thread with coupling K/KB 2” - 2” male thread with coupling - Internal thread BSPT or NPTKB 3” - Cast-iron flanges meeting BS 10, ISO, AWWA, JIS10.

Technical Specifications:

Volume based irrigation device, consisting of a water meter, a volume control dial and a valve all contained in a single unit.

• DescriptionThe Dose-O-Mat line of automatic metering valves provides a reliable and economical solution for a wide variety of irrigation applications.A variety of models and sizes are available to meet virtually any operational requirements and budget. The desired quantity is set using the volume control dial, according to local crop and soil. It automatically closes the valve once the pre-set quantity of water has passed through the unit. Dose-O-Mat units of sizes 11/2” and larger, contain hydraulic valves and may be installed either as single points of control or in groups that are operated in sequence. Operation is extremely simple, it does not require neither skilled labor nor intensive training

• Available SizesK/KB - Globe type: 3/4”,1”,11/2”,2”,3”KA/KBA - Angle type: 2”, 3”

Features:• Negligible head loss • Simple maintenance• Field replaceable measuring unit• Hermetically sealed register with glass lens• Bearings are constantly flushed during operation to eliminate deposit of solids• Optional electrical output: EV (Volume) or EF (Rate of Flow)• Compatible with Dialog automatic reading system

Page 11: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 9 |

Agriculture

Dimensions

Performance data

Model Nominal

Size(inch)

MaximumWorking Pressure

(bar)

MinimumWorking Pressure

(bar)

QmaxMaximum Flow Rate

(m3/h)

QminMinimum Flow Rate

(m3/h)

RegulatedFlow Rate

K/KA

3⁄4" 10 0.5 1.5 0.08

±2%

1" 8 0.5 5 0.5

1 1⁄2" 10 1 15 1.5

2" 10 1 30 2

KB/KBA

1 1⁄2" 10 1.3 15 1.5

2" 10 1.3 30 2

3" 10 1.5 65 3

• The meter should be installed in horizontal positionInstallation Requirements

Model K KA KB KBA

Nominal size(mm) 20 25 40 50 50 40 50 80 50 80

(inch) 3⁄4 1 11⁄2 2 2 11⁄2 2 3 2 3

L - Length without couplings (mm) 130 200 160 190 158 160 190 285 190 240

H - Height (mm) 86 115 203 235 265 203 235 350 290 364

A - (mm) - - - - 96 - - - 97 140

C - (mm) - - - - 122 - - - 122 140

B - Width (mm) 102 90 126 126 126 126 126 200 126 205

Weight (kg) 0.3 0.5 2.3 4.4 4 2.9 4.7 30 4.5 19

Weight with couplings (kg) - - 3.3 5.8 5.4 3.9 6.1 - - -

Head Loss Curve Standard ScalesScale

Model

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

1 3 10 20 25 40 50 100

200

400

1000

1600

2500

4000

5000

1000

0

K 3⁄4"- Ginon

K 1"

K 1 1⁄2"

K/KA 2"

KB 1 1⁄2"

KB/KBA 2"

KB/KBA 3”

* Other scales upon request.

C

A

Page 12: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 10 |

Agriculture

DOSE-O-MAT l Automatic Metering ValveModel KBJ/KBJA

Technical Specifications:Maximum Working Pressure

16 bar

Maximum Working Temperature

60°C

Body Cast iron body

Connection KBJ 11/2” - 11/2” BSP male thread with coupling. KBJ/KBJA 2” - 2” BSP male thread with coupling - Internal thread 2” BSPT or 2” NPTKBJ/ KBJA 3”- 8” - Cast iron flanges meeting BS 10, ISO, AWWA, JIS1

Volume based irrigation device, consisting of a water meter, a volume control dial and a double chamber valve contained in a single unit.

• DescriptionThe Dose-O-Mat line of automatic metering valves provides a reliable and economical solution for a wide variety of irrigation applications.A variety of models and sizes are available to meet virtually any operational requirements and budget. The desired quantity is set using the volume control dial, according to local crop and soil. It automatically closes the double chambered valve once the pre-set quantity of water has passed through the unit. Dose-O-Mat units that are 11/2” and larger contain a hydraulic double chamber valve and may be installed either as single points of control or in groups that operate are in sequence. Operation is extremely simple, it does not require neither skilled labor nor intensive training

• Available SizesKBJ - Globe type: 11/2”,2”,3”, 4”, 6”, 8”KBJA - Angle type: 2”, 3”, 4”, 6”, 8”

Features:• Simple to operate and maintain - just set it & forget about it.• High accuracy• Rugged, heavy-duty construction• Immune to fluctuations in line pressure• Low loss of head• Up to 30% saving compared to time based irrigation• Wide variety of flow and pressure regulation options• Wide variety of models & sizes - suitable for virtually all irrigation applications• Can function together with other units as part of an automatic, sequential irrigation system

Page 13: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 11 |

Agriculture

• The meter should be installed in horizontal positionInstallation Requirements

KBJ

H

LB

L

H

Ba

c

KBJA

Performance data

Model

Nominal Size

MaximumWorking Pressure

(bar)

MinimumWorking Pressure

(bar)

QmaxMaximum Flow Rate

(m3/h)

QminMinimum Flow Rate

(m3/h)

RegulatedFlow Rate

inch mm

KBJKBJA

1½ 40 16 1 15 1.5

2% ±

2 50 16 1 30 2

3 80 16 1 40 3

4 100 16 1 120 4.8

6 150 16 1 300 12

8 200 16 1 500 22

DimensionsModel KBJ KBJA

Nominal size(mm) 40 50 80 100 150 200 50 80 100 150 200

(inch) ½1 2 3 4 6 8 2 3 4 6 8

L - Length without couplings (mm) 160 190 270 320 500 600 158 243 277 440 525

H - Height (mm) 262 330 350 360 645 770 350 430 450 645 675

A - (mm) - - - - - - 96 140 162 250 300

C - (mm) - - - - - - 122 140 176 300 280

B - Width (mm) 120 120 210 210 380 450 120 210 230 380 450

Weight (kg) 2 3.8 21.5 29.5 120 150 3.5 19.5 28.5 111 140

Weight with couplings (kg) 3 5.2 - - - - 4.9 - - - -

Head Loss CurveStandard Scales

Scale

Model

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

m3

1 3 10 20 25 40 50 100

200

400

1,00

0

1,60

0

2,50

0

4,00

0

5,00

0

10,0

00

25,0

00

KBJ 1½”

KBJ/KBAJ 2”

KBJ/KBAJ 3”

KBJ/KBAJ 4”

KBJ/KBAJ 6”

KBJ/KBAJ 8”

* Other scales upon request.

Page 14: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 12 |

Agriculture

Plastic Fertilizer MeterModel SF

Maximum Working Pressure 5 bar

Maximum Working Temperature 50°C

Body PPS

Connection 3/4” BSP

Electrical output 0.1, 1, 10, 100 liter/pulse

Technical Specifications

The SF is a fertilizer & chemical solutions meter with electrical output and a totalizing register.The impeller is the only moving part, inside the meter, that comes into contact with the liquid.

• Applications•Fertilizing control in automated irrigation systems.•Industrial applications involving corrosive liquids.

• Available Sizes 1/2” (15mm)

Features:• Mechanical register with totalizer, 3 pointers and leakage

detector• High accuracy• Corrosion resistant plastic components.• Small & lightweight.Compatible with Dialog automatic

reading system

Page 15: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 13 |

Agriculture

Model SF

Nominal size(mm) 15

(inch) 1/2

L - Length (mm) 110

H - Height (mm) 81

B - Width (mm) 77

Weight (kg) 0.28

Dimensions

Performance data:

Model SF Qmax Maximum flowrate

(l/h)

QtLowest Flowrate

Measured between ±2%

(l/h)

QminLowest Flowrate

Measured between ±5% (l/h)

Loss of Head at Maximum flow rate

(bar) Nominal size

(mm) (inch)

15 1/2 750 70 25 0.12

• The fertilizer meter should be installed in horizontal positionInstallation Requirements

Head Loss CurveAccuracy Curve

1. SF Fertilizer Meter2. Irrigation computer3. Fertilizer tank4. Hydraulic valve5. Water meter6. Hydraulic valve7. Flow limiter valve8. Fertilizer Pump9. 75 mm damping pipe

Installation Scheme

Page 16: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 14 |

Agriculture

DISHNON - Fertilizer meter with electrical outputModel KD

The DISHNON is a small meter, which is resistant to fertilizer and similar chemicals and which transmits electrical data to automated control systems. The DISHNON contains a small measuring chamber and a magnetic proximity switch made of synthetic polymers and metals capable of withstanding all fertilizer materials currently in common use.

Applications• Automated irrigation systems• Automated industrial applications using corrosive liquids

Available Sizes1/2” (15mm)

Features:• Compatible with virtually any type of automated control system• High accuracy• Dry contact electrical output• Corrosion resistant plastic and metal components

Technical Specifications:Maximum Working Pressure 16 bar

Maximum Working Temperature

50°C

Body Corrosion resistant plastic

Connection 3/4” BSP

Page 17: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 15 |

Agriculture

Installation Requirements• The fertilizer meter should be installed in horizontal position

Performance data Electrical output data

Model

QmaxMaximumflowrate

(l/h)

QminMinimumflowrate

(l/h)

Model Pulseper unit V max I max Cable

Length

N-KD 750 60 N-KD 0.1, 0.25, 1, 1028V DC 50 mA 1.5 meter

S-KD 500 20 S-KD 0.05

DimensionsModel KD

Nominal size(mm) 15

(inch) ½

L - Length (mm) 136

H - Height (mm) 86

B - Width (mm) 100

Weight (kg) 0.3

H

BL

Head Loss Curve

1. KD Fertilizer Meter2. Irrigation computer3. Fertilizer tank4. Hydraulic valve5. Water meter6. Hydraulic valve7. Flow limiter valve8. Fertilizer Pump9. 75 mm damping pipe

Installation Scheme

Page 18: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 16 |

Agriculture

Plastic Body Liquid Chemical MeterModel PB

The PB is an angle type, plastic body, multi-jet liquid chemical meter.

Applications• Measuring flow of fertilizer solutions, for agriculture, distilled water,

seawater and many other diluted solutions

Available Sizes• 3/4” - 1” (20 - 25mm)

Features:• The impeller is corrosion resistant and is the

only moving element that comes in contact with the liquid

• Electrical output (EV)

Technical Specifications:Maximum Working Pressure 10 bar

Maximum Working Temperature

50°C

Body PVC

Connection 1” BSP

Electrical output 1, 10, 100 liter/pulse

Page 19: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 17 |

Agriculture

Installation Requirements• The meter should be installed with dial face in horizontal position

Performance dataModel PB Qmax

Maximumflowrate

(m3/h)

QnNominal Flowrate

(m3/h)

QtTransitional

Flowrate(l/h)

QminMinimum Flowrate

(l/h)

Minimum register capacity

(m3)

Minimum register capacity

(Liter)

Accuracy between

Qmax & Qt

Accuracy between

Qt & QminNominal Size

inch mm

¾ 20 5 2.5 200 50 105 0.12% ± 5% ±

1 25 10 5 400 100 105 0.1

DimensionsModel PB

Nominal size(mm) 20 25

(inch) ¾ 1

L - Length (mm) 150

l - Length (mm) 90

H - Height (mm) 150

h - Height (mm) 115

B - Width (mm) 120

Weight (kg) 0.875

L

B

H

h

l

Head Loss Curve Accuracy Curve

Page 20: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 18 |

Agriculture

Pilot Valves Model PC

Arad Pilot Valves PC work together with BM/BMA series high pressure Hydrometers or with KBJ/KBJA series high pressure metering valves in automated environments requiring pressure regulation. These pilot valves are also compatible with valves and hydrometers from many other manufacturers.These valves may be used in a variety of control applications. The pressure regulating model is available in normal pressure or low pressure configurations.The pilot valve body is made of high quality reinforced plastic.Calibration may be performed by means of an adjusting screw located on the top of the valve.

ApplicationsThe model PC pressure regulating pilot valve is used in pressure reducing and pressure sustaining applications. Two pressure regulating pilot valves may be combined together to form a two stage operation, combining both pressure reducing and pressure sustaining functions in order to prevent excess water flow during pipeline filling.

Technical Specifications:Maximum Working Pressure 10 bar

Maximum Working Temperature 70°C

Pressure regulation accuracy 0.3 bar

Body Plastic Sustaining/Reducing Pressures according to Pilot types

Unit Type Pressures

Nominal size BAR psi

Blue 0.3-1.4 5-20

Green 1-3 14.5-43.5

Gray 2-8 29-116

Typical Pressure Regulating Environment

Page 21: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 19 |

AgriculturePilot Valves Model FC

Arad Pilot Valves FC work together with BM/BMA series high pressure Hydrometers or with KBJ/KBJA series high pressure metering valves in automated environments requiring flow regulation. These pilot valves are also compatible with valves and hydrometers from many other manufacturers.These valves may be used in a variety of control applications.The pilot valve body is made of high quality reinforced plastic.Calibration may be performed by means of an adjusting screw located on the top of the valve.

ApplicationsThe model FC flow regulating pilot valve is used individually for flow regulating applications or together with a model PC pressure regulating pilot valve in combined flow and pressure regulating applications.

Technical Specifications:Maximum Working Pressure 10 bar

Maximum Working Temperature 70°C

WP 0.3: 0.6 bar

Regulation Accuracy ±8% of flow rate

Body Plastic

Typical Pressure Regulating Environment

Page 22: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 20 |

Agriculture

The constantly growing penetration of automation and computerized data processing into water usage, in agriculture, industry, urbanic water supply systems and any other field where more is required than just the traditional mechanical register of water meters, creates a high demand for measuring instruments which are able to provide electrical information about the flow.Arad Water Meters equipped with electrical output devices combine the high reliability of the hermetically sealed, magnetically driven register with a wide variety of electric output options.All existing Arad Water Meters with magnetic registers can be easily upgraded to include electrical output.

• Application Examples

1. Remote ReadingIn combination with a remote reading system, or computerized data acquisition system, it is possible to collect and process water usage data in multi-apartment houses, in places with no access, or wherever it is required to bring all data to one point.

2. Flowrate MeasuringWith the appropriate type of electrical output it is possible to obtain on-line information about the flowrate which can be displayed, stored or both.

3. Flowrate ControlWith the appropriate type of electrical output and additional electronic control device it is possible to perform various functions like the operation of valves, pumps or alarm signals according to various preset levels of flowrate.

4. Bi-directional Flow MeasurementWith the appropriate electrical output and an additional electronic module it is possible to distinguish between flow directions, to measure and record flow rates and volumes passed in each direction.

5. BatchingFeeding electrical output to a batching controller enables pre-setting and delivering of accurate volumes of water in irrigation systems, industrial process etc.

Register output optionsElectrical Output Versions

Page 23: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 21 |

Agriculture

• Transducer Types - Description & Specifications1. Reed Switch (EV) Sensor

A magnet activates this sensor. It acts as a “Dry Contact” and does not consume electric power. This is the most suitable sensor for “VOLUME” related functions and in such applications its operating life is practically unlimited (ca. 108 cycles).

Electrical specifications:a. Max. contact current - 50 mAb. Max. contact voltage - 48 V

2. Photo-Diode (EF) SensorThis sensor combines an IR light source and a light sensitive diode in one package. Signals are created by letting the light pass through, or reflected from a rotating element in the register in an interrupted mode. It requires a constant supply of power.

Electrical specifications:a. Currentsupplies-20•30mAthrougharesistor(seefollowingtableforvalues). Lead color code - yellow.b. Output - open collector. Max. Load - 2 mA. Lead color code - transparent.c. Circuit diagram:

d. Recommended resistor values table:

VOLTAGE (V+) RESISTOR VALUES

Ω W

5 180 0.25

6 220 0.25

9 330 0.25

12 470 0.5

24 1000 1NOTE: Correct polarity of the leads should be checked carefully to prevent damage of the sensor.

1. VOLUME OUTPUT- Reed Switch1.1 SINGLE VOLUME OUTPUT

A 3 pointer register with magnet installed on one of them.Output definition: “Volume output”. Output type: EV.The reed switch sensor is installed in sealed transparent plastic cover that can be mounted on the register in any one of 3 positions facing the pointer with the magnet.3 values of output are thus available in 1:10:100 ratios.

1.2 IP 68 SINGLE VOLUME OUTPUTA 3-pointer register with a magnet installed on one of them.Output definition: “Volume output”. Output type: EV.The IP68 configuration is a sealed structure that can be mounted on the register shroud in a WSTsb Bayonet configuration in any of 3 positions facing the pointer with the magnet. 3 values of output are thus available in 1:10:100 ratios. Once assembled the IP68 configuration is fixed and sealed on the needed output.IP68 standard means that the assembly is totally protected against dust and protected against long periods of immersion under pressure.

• Registers Types

Page 24: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 22 |

Agriculture

1.3 DOUBLE OUTPUTA 3 pointer register with magnet installed on one of them.Output definition: “volume output”. Output type: EV-D.The output device contains 2 reed switches. All the components are sealed within a plastic module.A unique feature of this unit is the immunity from conditions that might create false pulses due to back and forth fluctuations of standing water in pipe line containing air pockets, or where mechanical vibrations of the pipe exist.

2. VOLUME OUTPUT- Photo DiodeA 3 pointer register with a serrated wheel on the first pointer shaft for activating a photo-diode sensor.Output definition: “Volume output”. Output type: EF-P.The serrated wheel has 10 “teeth” creating 10 signals per revolution, each signal represents 1/10 the full-scale value at this position in the register.

3. VOLUME OUTPUT- Optical Encoder (OE)A 3-pointer register with a reflective half coated wheel on the first pointer shaft for activating a sensor.Output definition: “Volume output”. Output type: Open Drain.The reflective wheel has a golden coating on half of its area- creating one pulse per revolution output in a forward flow; there’s no output in a reverse flow.Each pulse presents one full-scale value at this position in the register.

4. FLOWRATE OUTPUT- Photo DiodeA 3 pointer register with a serrated wheel mounted on the central shaft of the register for activating a photo-diode sensor.Output definition: “Flowrate output”. Output type: EF.The sensor is installed and sealed within a transparent plastic cover. The high number of “teeth” and the relatively high speed of the central shaft create a rapid stream of signals in frequency proportional to the rate of flow. Fed into suitable electronic units these signals are translated into flowrate values that can be expressed in any desirable units.

5. DUAL PURPOSE ELECTRONIC- DPEElectronic register showing rate of flow and accumulated volume. The register has LCD with 6 digits. The register has interchangeable presentation (every 30 seconds) between the rate of flow and volume. Mounted inside stainless steel vacuumed encapsulated cup with glass lens, hermetically sealed IP 68. Can be installed on any Arad meter and hydrometer. Can be programmed for various units: Flow Rate: GPM, m3/h, liter/secVolume: Gallons, Cubic Feet, Acre Feet, m3

6. MULTI PURPOSE ELECTRONIC- MPEElectronic register showing three interchangeable displays (every 10 seconds) on LCD display (1 display of flow an 2 displays of accumulated volume), with high resolution and EV passive output.Mounted inside stainless steel vacuumed encapsulated cup with plastic lens, hermetically sealed IP67.Can be installed on any Arad meter and hydrometer.

Page 25: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 23 |

Agriculture

General Remarks Concerning the Various Types of Electrical Outputs1. All the sensors are mounted on the register in a non-invasive mode.2. All types of outputs may be installed on all ARAD water meters.3. All “Volume outputs” sensors of types EV and EV-D may be installed or replaced without disassembling the register.

Water Meter Available Pulse Value & Sensor Type

Model SizeLit. M3

0.1 1 10 100 1 10 100 1000 10000

Multi-Jet M 1/2” - 1” EF-P EV EV EV

11/2” - 2” EF-P EV EV EV

Gladiator 1/2" and 3/4" EV / OE EV EV

Positive Displacement P 1/2” - 3/4” EV EV EV

Multi-Jet Q 1/2” EV EV EV

WoltmanWMRWTWSTWSTsb

2”-3” EF-P EV / OE EV EV

4”-6” option 1 EF-P EV / OE EV EV

4”-6” option 2 EF-P EV / OE EV EV

8”-12” EF-P EV / OE EV EV

IrrigationMeterIRT

3"-8” EF-P EV EV EV

10" EF-P EV EV EV

CompoundWater MeterM-WT

2" x 1/2" WT - Look under WoltmanM - Look under Multi-jet3" x 3/4"

4" x 3/4"

6" x 11/4"

HydrometerBM/BMA

11/2" - 3" EF-P EV EV EV

4" - 6" EF-P EV EV EV

8" EF-P EV EV

DOSE-O-MATKB/KBAKBJ/KBJA

11/2" - 4" EV EV

6" - 8" EV EV

Fertilizer MeterDishnonSF

1/2” EV EV EV EV

EV - Reed SwitchEF-P - Photodiode on PointerOE - Optical Encoder

Page 26: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 24 |

Warranty

Arad’s standard products (the “Products”) are sold to Customer and are purchased by Customer under the terms of warranty set forth herein below:

1. Arad warrants that the Products shall, under conditions of normal use and when properly installed, administered, applied and maintained, be free from defects in material and workmanship (the “Warranty”), for a period of 12 months following delivery thereof to Customer (the “Warranty Period”).

2. Arad's sole obligation and liability under the Warranty shall be limited to the replacement, the repair or the refund of the original purchase price, at Arad's sole discretion, of any defective Products which are proven not to conform to the Products' specification and which are returned to the factory or service center designated by Arad during the Warranty Period by the Customer after completing a failure report. All provided that written notice of such defect is given by the Customer to Arad within 21 days after discovery thereof. Freight cost to such factory or service center will be paid by the Customer and freight cost from such factory or service center to Customer will be paid by Arad.

3. Arad will not be responsible for and will have no obligation under the Warranty to any non-conformity of the Products, caused, in whole or in part, as a result of misuse, abuse, tampering with or modification of any of the Products and/or by accidents, fault or negligence, improper administration, application and/or use, installation, service, repair and/or maintenance of the relevant Products, by act of vandalism or by any causes whatsoever (including but not limited to environmental conditions) that are external thereto.

4. The foregoing warranty is a limited warranty and is exclusive and in lieu of all other warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose and shall constitute the Customer's sole and exclusive remedy with respect thereto. Replacement or repair in the manner provided above will constitute fulfillment of all of Arad's obligations with respect to the quality and performance of the products. No dealer, distributor, agent or employee of either Arad or customer is authorized to modify these warranties. Such modification shall be null and void and shall not bind Arad for any and all purposes.

5. Except and to the extent provided under the warranty, in no event shall Arad be liable, whether in contract, tort or otherwise, for any damages, whether direct or, indirect, consequential, incidental, special or punitive, resulting from any defect in the products, including, without limitation, loss of profits, business, income, anticipated savings, goodwill or other commercial loss, even if Arad had been advised of the possibility of such damages, except to the extent that such liability may not lawfully be excluded.

Customer shall be solely responsible for the selection, use, efficiency and suitability of the Products.

Page 27: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

| 25 |

Warranty

Page 28: METERS AMR/AMI CONTROL AGRICULTURE Produc ts Catalog · Model WMR Maximum Working Pressure 16 bar Maximum Liquid Temperature 55°C Body Iron, polyester coated Connection 2” BSP

June

201

3

A Member of the

Integrated Meter ing Technologies

Arad Ltd. 1923900 Dalia, IsraelTel: (972)4-9897911 Fax: (972)4-9897965

w w w . a r a d . c o . i l