22
765 AP/ AD HNB/G USB/G FAB/G FGB/G FVB FWB/G FHB FLB AB AG CHB/G MXB/G SAB/ SVB HVB/ HVL For dry air NP/NAP/ NVP PD/FAD/ PJ CVE/ CVSE CPE/ CPD Custom order Medical analysis Other G.P. systems APK/ ADK Explosion proof Medical analysis process components Medical analysis process components In recent years, medicine has greatly advanced and medical engineering has become a great priority. These advances have increased the need for highly functional, performing and accurate biomedical inspections and devices in clinical medicine. To answer these advanced needs for medical analysis process components, CKD has set the following six target items for medical technology, and has prepared special specification control valves to match these targets. Select the component that matches your needs. Overview Compact and lightweight The components have been downsized and lightened to handle changes from centralized medicine to portable medicine. Low noise In consideration of hospital environments, the valves function with an extremely quiet drive. Minimal residue The fluid accumulation and fluid residue have been minimized to allow for the fluid accuracy and safety in various inspections. Maintenance-free The life of the parts has been increased, and a maintenance-free design has been incorporated to improve the reliability of the devices. High sealing performance High corrosion resistant materials and a high sealing structure have been incorporated to ensure the purity of inspection fluids. Wide variation A variety of models are available to match a diverse range of reagents and inspection fluids. Features CONTENTS Series variation 766 Safety precautions 768 Compact metal free for chemical liquid 2, 3 port solenoid valve MR10 772 MAB1/MAG1 776 MYB1/MYG1 779 MYB2/MYG2 782 MYB3/MYG3 785 MEB2/MEG2 788 Lever type HMTB1/HMTG1 802 2 port solenoid valve MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port valve HYN 811 Electronic Catalog file list 813 For water, pure water, chemical liquids (fluids that do not corrode materials at wetted parts) Always read the precautions in the Introduction and page 768 before starting use. 765

Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

765

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

s

Medical analysisprocess components

In recent years, medicine has greatly

advanced and medical engineering

has become a great priority. These

advances have increased the need

for highly functional, performing and

accurate biomedical inspections and

devices in clinical medicine.

To answer these advanced needs for

medical analysis process components,

CKD has set the following six target

items for medical technology, and

has prepared special specification

control valves to match these

targets. Select the component that

matches your needs.

Overview

Compact and lightweightThe components have been downsized and lightened to handle changes from centralized medicine to portable medicine.

Low noiseIn consideration of hospital environments, the valves function with an extremely quiet drive.

Minimal residueThe fluid accumulation and fluid residue have been minimized to allow for the fluid accuracy and safety in various inspections.

Maintenance-freeThe life of the parts has been increased, and a maintenance-free design has been incorporated to improve the reliability of the devices.

High sealing performanceHigh corrosion resistant materials and a high sealing structure have been incorporated to ensure the purity of inspection fluids.

Wide variationA variety of models are available to match a diverse range of reagents and inspection fluids.

Features

C O N T E N T SSeries variation 766

Safety precautions 768

Compact metal free for chemical liquid

2, 3 port solenoid valve� MR10 772� MAB1/MAG1 776� MYB1/MYG1 779� MYB2/MYG2 782� MYB3/MYG3 785� MEB2/MEG2 788� Lever type HMTB1/HMTG1 802

2 port solenoid valve

� MJB3 791� EMB21 793� EMB41/51 795� M 798

High corrosion resistant

� 2, 3 port valve UMB1/UMG1 805� 2 port valve HB 807

Pinch valve

� 2, 3 port valve HYN 811

Electronic Catalog file list 813

� For water, pure water, chemical liquids(fluids that do not corrode materials at wetted parts)

Always read the precautions in the Introduction and page 768 before starting use.

765

Page 2: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

766

FluidMaterial

PurewaterBodySealant

2, 3

2

3

2

3

2

3

2

3

2

3

2

2

2

2

2

3

2

3

2

3

2

2, 3

MR10

MAB1

MAG1

MYB1

MYG1

MYB2

MYG2

MYB3

MYG3

MEB2

MEG2

MJB3

EMB21

EMB41/51

M

HMTB1

HMTG1

USB2/3

USG2/3

UMB1

UMG1

HB

HYN

FKM

PTFE

PTFE

FKM

FKM

FKM

FKM

FKM

FKM

PTFE

PTFE

FKM

FKM

-

PEEK

PTFE

PTFE

PPS

PPS

PPS

PPS

PPS

PPS

PPS

PPS

PSU

PTFE

PPS

PPS

SUS316

-

Physiologicalbrine

No. of portModelReagent Waste

liquidCleaning

liquid

Dia

phra

gm ty

pe

Met

al fr

ee fo

r ch

emic

al li

quid

Hig

h co

rros

ion

resi

stan

t

Leve

rty

pe

Pinc

hva

lve Metal freetype

Pop

pet t

ype

Sol

enoi

d va

lve

Note: Check the compatibility between working fluid and body/sealant materials when selecting.

PTFEFKMPTFEFKMSiliconrubber

NBRFKM

EPDM

NBR(FKM)(PTFE)

PPS

NBRFKMNBRFKM

SUS304or equiv.SUS304or equiv.

PTFEPVC

PTFEFKM

SUS316PTFE ��

����

Series variation Medical analysis process components

Page 3: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

767

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

s

�1.6 orequiv.

�1.6 orequiv.

�2.0 orequiv.�

2.0 orequiv.

�3.0 orequiv.�

3.0 orequiv.

772

776

776

779

779

782

782

785

785

788

788

791

793

795

798

802

802

16

16

805

805

807

811

Orifice (ø/mm)

0.5 0.9 1 1.5 1.6 2 2.3 3 3.2 4 5 6 7 8 10 1512Page

�5.0 orequiv.�

5.0 orequiv.

�3.0 orequiv.�

3.0 orequiv.

�Tube

ID

�Tube

ID

�Tube

ID

� � � � � �

�Tube

ID

Page 4: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

768

Medical analysis process components <<Precautions for each model>>

1

Design & Selection

WARNINGWorking environmentWhen using in a place where water splashes on the valve, take appropriate measures to protect it.

1

Installation, Piping & Wiring

CAUTIONTighten the piping with the following torques. Note that if the solenoid valve body is made of resin, a resin joint must be used. The port could be damaged if a metal joint is used.

1

CAUTION(1) Working fluids must not adhere to the product body. (2) Carefully select the solenoid valve taking the chemical

liquid characteristics into consideration. (Presence of crystal deposits when chemical liquids dry, effect to solenoid valve component materials if chemical liquids evaporate, etc.)

(3) When using these components for a chemical liquid having a low boiling point, such as hexane, the chemical liquid in the solenoid valve could evaporate due to heating of the coils, and cause bubbles, etc. in the solenoid valve and pipe. Use an AMD type air operated valve for chemical liquid if formation of bubbles, etc. poses a problem.

(4) When using the solenoid valve with a negative pressure, such as for dispensing control, air may be sucked into the solenoid valve depending on the type of chemical liquid, type of connection joint, and type of tube, etc. Check the state carefully before starting use.

CAUTION

Safety Precautions for MAB1/MAG1

(1) Foreign matter in the piping and the environment during piping work could damage the valve seat or diaphragm seal, and lead to leaks. Always flush the piping before installing the valve.

(2) When using strong acids, such as hydrochloric acid, hydrofluoric acid or nitric acid, or sodium hypochlorite (soda), use an AMD type air operated valve for chemical liquid.

(3) Consult with CKD if the secondary piping is laid at a high level or extremely restricted.

(4) Do not disassemble the product. The required performance may not be satisfied even if a disassembled product is reassembled.

CAUTION

Safety Precautions for MR10

(1) Before starting use, check the compatibility between the materials of the product and working fluid.

(2) Do not use for hydrochloric acid, hydrofluoric acid, nitric acid or sodium hypochlorite (soda).

(3) Foreign matter etc. inside the piping may cause malfunction and valve seat leakage. Make sure to flush the piping.

(4) When standing the secondary piping, do not make it higher than 2 m. Use tubing or piping with the same or larger bore size as the orifice to fix the pipe.

(5) Do not disassemble the product. The required performance may not be satisfied even if a disassembled product is reassembled.

CAUTION

Safety Precautions for MYB /MYG /MEB2/MEG2123

123

(1) Before starting use, check the compatibility between the materials of the product and working fluid. Working fluids must not adhere to the product body.

(2) Foreign matter in the piping and the environment during piping work could damage the valve seat or diaphragm seal, and lead to leaks. Always flush the piping before installing the valve.

(3) Do not use metal joints because they could damage the port. Use a PP or fluorine resin joint. Tighten the joint with the recommended tightening torque shown in the table.

<<Stainless steel body solenoid valve>>

Nominal pipe diameterM5

Rc1/8Rc1/4Rc3/8

Tightening torque [N·m]2.1 to 318 to 2023 to 2531 to 33

<<Fluorine resin body solenoid valve>>

Nominal pipe diameterM6

Rc1/4Rc3/8, R3/8Rc1/2, R1/2

R3/4

Tightening torque [N·m]0.05 to 0.080.7 to 1.01.0 to 1.51.5 to 2.02.0 to 2.5

<<Polyvinyl chloride body solenoid valve>>

Nominal pipe diameterR3/8R1/2R3/4

Tightening torque [N·m]1.5 to 2.02.0 to 2.52.5 to 3.0

<<PPS/PEEK body solenoid valve>>

Nominal pipe diameterM5, M6Rc1/8Rc1/4Rc3/8

Tightening torque [N·m]0.10 to 0.150.5 to 0.81.0 to 1.51.0 to 1.5

Safety precautionsAlways read this section before starting use.

Page 5: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

769

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

s

(EMB51-10-3) (MPa)

(EMB51-15-4) (MPa)

(EMB51-15-5) (MPa)

0.15

0.1

0.12

0.05

0.1

0.1

0 3 6(m)

0 3 6(m)

0 1 3(m)

P↑

P↑

P↑

Pressurizedwater tank

PS

L LP :

::

Valve primary side total pressureSecondary side pipe length

Max. working pressure(value given in catalog)200 mm

(EMB41-10-3) (MPa)0.25

0.2

0 3 6

6

0.1

(m)L →

P↑

(EMB41- -5) (MPa)

0 3

0.2

0.1

(m)L →

P↑

10U10

L →

L →

L →

Safety Precautions for EMB41/EMB51

(1) Foreign matter in the piping and the environment during piping work could damage the valve seat or diaphragm seal, and lead to leaks. Always flush the piping before installing the valve.

(2) Use VCTF-0.75 (2-conductor: outer diameter 6.6) vinyl code for equipment (JISC3306) for the led out wires.

(3) Use the PFA-10-8 for the EMB41-10U tube. (4) Consult with CKD if the secondary piping is laid at a

high level. (5) When using strong acids, such as hydrochloric acid,

hydrofluoric acid or nitric acid, or sodium hypochlorite (soda), use an AMD type air operated valve for chemical liquid.

(6) The working pressure changes particularly according to the OUT side piping conditions, so refer to the characteristics in the following graph before using (note that these characteristics are for water).

CAUTION

CAUTION

Safety Precautions for MB21

(1) Foreign matter in the piping and the environment during piping work could damage the valve seat or diaphragm seal, and lead to leaks. Always flush the piping before installing the valve.

(2) Consult with CKD if the secondary piping is laid at a high level.

(3) When using strong acids, such as hydrochloric acid, hydrofluoric acid or nitric acid, or sodium hypochlorite (soda), use an AMD type air operated valve for chemical liquid.

(4) Do not disassemble the product. The required performance may not be satisfied even if a disassembled product is reassembled.

CAUTION

Safety Precautions for MJB3

(1) Before starting use, check the compatibility between the materials of the product and working fluid. Working fluids must not adhere to the product body.

(2) Foreign matter etc. inside the piping may cause malfunction and valve seat leakage. Always flush the piping before installing the valve.

(3) Do not use for hydrochloric acid, hydrofluoric acid or nitric acid. Before using a permeable fluid, contact CKD. The fluid could permeate the diaphragm.

(4) Consult with CKD if the secondary piping is laid at a high level (2 m or higher) or extremely restricted.

(5) Do not apply excessive force on the joint when connecting or disconnecting the tube.

(6) Do not disassemble the product. The required performance may not be satisfied even if a disassembled product is reassembled.

(4) When using strong acids, such as hydrochloric acid, hydrofluoric acid or nitric acid, or sodium hypochlorite (soda), use an AMD type air operated valve for chemical liquid.

(5) Current leakage from the control circuit must be less than that specified for each voltage.

(6) Consult with CKD if the secondary piping is laid at a high level (2 m or higher) or extremely restricted.

(7) Do not disassemble the product. The required performance may not be satisfied even if a disassembled product is reassembled.

Page 6: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

770

Medical analysis process components

<<Precautions for each model>>Safety Precautions for HB

CAUTION(1) Foreign matter etc. inside the piping may cause

malfunction and valve seat leakage. Always flush the piping before installing the valve.

(2) Do not disassemble the product. The required performance may not be satisfied even if a disassembled product is reassembled.

(3) When using strong acids, such as hydrochloric acid, hydrofluoric acid or nitric acid, or sodium hypochlorite (soda), use an AMD type air operated valve for chemical liquid.

Safety Precautions for HYN

CAUTION(1) The power supply voltage must be 24 VDC

(average) with a ripple of 4.8 VP-P or less. (When using an average of 12 VDC, the ripple must be 2.4 VP-P or less. )

(2) When using a DC-specification product with a full wave rectified AC power supply, the power must be smoothed to attain the forementioned ripple voltage range. Consult with CKD for more information.

(3) Tighten the HYN-2/3 screw with a torque of 0.2 to 0.4 N·m, and the HYN-5/8 screw with a torque of 0.5 to 0.7 N·m. (When the screw engagement length is 5 mm)

(4) Securely insert the tube to the designated position.

(5) The performance may not be satisfied if a tube other than the recommended ones is used.

(6) Depending on the working fluid, the silicon tube may not be resistant to chemical liquids, or chemical liquids may adhere. Check this before use.

(7) The DC specification product has polarity.(Red =  )

(8) Do not disassemble the product. The required performance may not be satisfied even if a disassembled product is reassembled.

(9) Do not apply water on the coils.

CAUTION

Safety Precautions for UMB/UMG

(1) Do not disassemble the product. The required performance may not be satisfied even if a disassembled product is reassembled.

(2) Do not apply a torque exceeding 0.3 N·m on the mounting bolt (M3).

(3) Protect the product against contact with water. Water could cause insulation or operation faults.

(4) When using strong acids, such as hydrochloric acid, hydrofluoric acid or nitric acid, or sodium hypochlorite (soda), use an AMD type air operated valve for chemical liquid.

Safety Precautions for M

CAUTION(1) Oil is sealed inside, so do not disassemble the

product. (2) This product is not oil free. (3) If the diaphragm is damaged during use, oil will

flow into the fluid. Consider this when making a selection.

(4) When using strong acids, such as hydrochloric acid, hydrofluoric acid or nitric acid, or sodium hypochlorite (soda), use an AMD type air operated valve for chemical liquid.

CAUTION

Safety Precautions for HMTB/HMTG

(1) Use a direct current power supply excluding rectified direct current.

(2) Do not apply excessive force on the joint when connecting or disconnecting the tube.

(3) Do not disassemble the product. The required performance may not be satisfied even if a disassembled product is reassembled.

(4) When using strong acids, such as hydrochloric acid, hydrofluoric acid or nitric acid, or sodium hypochlorite (soda), use an AMD type air operated valve for chemical liquid.

�+

Safety precautionsAlways read this section before starting use.

Page 7: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

776

SpecificationsItem

Water, pure water, chemical liquids (fluids that do not corrode materials at wetted parts)

5 to 60

0 to 50 (no freezing)

Not in explosive or corrosive environment

0 (water pressure)

M6 (*4)

Equivalent to 1.6

0.045

Free

0.13

Continuous

24 VDC

-10 to +10% of rated voltage

2.3

2.4 or less (*6)

B

Conditions

IN positiveOUT positiveIN negative

Fluid flow direction

IN → OUTOUT → INOUT → IN

IN OUT0 to 0.30 to 0.1

-0.05 to 0

0 to 0.10 to 0.1

-0.05 to 0

Working pressure range of each port

MAB1-M6-DC24V MAG1-M6-DC24V

JIS symbol� MAB1 (2 port)

: NC (normally closed) type

˚C˚C

cm3/min.

mm

kg

WmA

Working fluid

Fluid temperatureAmbient temperatureAtmosphereValve seat leakagePort sizeOrificeCv flow factorMounting attitudeWeightElectric specificationsRatingVoltageVoltage fluctuation rangePower consumptionLeakage currentHeat proof class

� MAG1 (3 port)

: universal type

DescriptionsSymbol

BG

2 port valve3 port valveModel no.

How to order

M6 DC24V

Working pressure range MPa

MA B 1

A No. of port

Conditions

COM positiveNC positiveNO positiveCOM negative

Fluid flow direction

COM → NO or NCNC → COMNO → COM

NO or NC → COM

COM NC NO0 to 0.30 to 0.10 to 0.1

-0.05 to 0

0 to 0.10 to 0.10 to 0.1

-0.05 to 0

0 to 0.10 to 0.10 to 0.1

-0.05 to 0

Working pressure range of each port

*1: Read the safety precautions for MAB1/MAG1 (page 768). *2: Before starting use, check the compatibility between the materials of the product and working fluid.

Working fluids must not adhere to the product body. *3: Foreign matter etc. inside the piping may cause malfunction and valve seat leakage. Always flush the piping

before installing the valve. *4: Do not use metal joints because they could damage the port. Use a PP or fluorine resin joint.

Wrap PTFE sealing tape two to thee times around the joint. Tighten the joint with the recommended tightening torque below. Recommended tightening torque: 0.05 to 0.08 N·m

*5: Do not use for hydrochloric acid, hydrofluoric acid, nitric acid or sodium hypochlorite (soda). *6: Keep leakage current from the control circuit within the levels below. *7: When standing the secondary piping, do not make it higher than 2 m. Use tubing or piping with the same or

larger bore size as the orifice to fix the pipe. *8: Do not disassemble the product.

A No. of port

OUT

COM

IN

NC NO

Metal free 2, 3 port solenoid valve for chemical liquid

MAB1/MAG1 Series� NC (normally closed) type, universal type� Working fluid: water, pure water, chemical liquids� Port size: M6

Page 8: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MAB1/MAG1 Series

777

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

sC

ompa

ct m

edic

al fr

ee

Internal structure and parts list� MAB1-M6-DC24V

10

7

5

3

2

1

� MAG1-M6-DC24V

Coil assembly

Spring

Plunger

Cap

Diaphragm

Parts name

SUS304

SUY

SUS304

PTFE

Stainless steel

Iron

Stainless steel

Tetrafluoroethylene resin

Ceramic

Tetrafluoroethylene resin

Stainless steel

Stainless steel

Stainless steel

Material

Rod

Body

Spring holder

Spring

Mounting plate

Parts name

PTFE

SUS304

SUS304

SUS303

Material

7

6

5

5

4

4

8

9

10

3

2

1

12345

No.678910

No.

Page 9: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MAB1/MAG1 Series

778

Dimensions� MAB1-M6-DC24V

MADE IN JAPAN

5300

2-M6 depth 6Prepared hole depth 7.2 entrance ø8

25.5IN OUT

13.5

ø25

ø26

(54)

2-M3 depth 6

15

� MAG1-M6-DC24V

MADE IN JAPAN

NC NO

COM

(54)

ø26

ø25

13.5

COM

M

5300

25.5

NO

15

2-M3 depth 6

3-M6 depth 6

Prepared hole depth 7.2 entrance ø8

OUT

(Page 813)

Page 10: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

779

Metal free 2, 3 port solenoid valve for chemical liquid

MYB1/MYG1 Series� NC (normally closed) type, universal type� Working fluid: water, pure water, chemical liquids� Port size: M6

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

sC

ompa

ct m

edic

al fr

ee

SpecificationsItem

Water, pure water, chemical liquids (fluids that do not corrode materials at wetted parts)

5 to 60

0 to 50 (no freezing)

Not in explosive or corrosive environment

0 (water pressure)

M6 (*4)

Equivalent to 2.0

0.1

Free

0.14

Continuous

12 VDC, 24 VDC, 100 VAC (50/60 Hz)

-10 to +10% of rated voltage

3.8

3.0

2 or less (12 VDC) / 1 or less (24 VDC) / 1.5 or less (100 VAC) (*6)

B

MYB1-M6 MYG1-M6

JIS symbol

˚C˚C

cm3/min.

mm

kg

ACDCmA

Working fluid

Fluid temperatureAmbient temperatureAtmosphereValve seat leakagePort sizeOrificeCv flow factorMounting attitudeWeightElectric specificationsRatingVoltageVoltage fluctuation rangePower consumption

Leakage currentHeat proof class

How to order

Working pressure range MPa

W

Conditions

COM positiveNC positiveNO positiveCOM negative

Fluid flow direction

COM → NO or NCNC → COMNO → COMNO or NC → COM

COM NC NO0 to 0.20 to 0.10 to 0.1

-0.05 to 0

0 to 0.10 to 0.10 to 0.1

-0.05 to 0

0 to 0.10 to 0.10 to 0.1

-0.05 to 0

Working pressure range of each portConditions

IN positiveOUT positiveIN negative

Fluid flow direction

IN → OUTOUT → INOUT → IN

IN OUT0 to 0.20 to 0.1

-0.05 to 0

0 to 0.10 to 0.1

-0.05 to 0

Working pressure range of each port

*1: Read the safety precautions for MYB1/MYG1 (page 768). *2: Before starting use, check the compatibility between the materials of the product and working fluid.

Working fluids must not adhere to the product body. *3: Foreign matter etc. inside the piping may cause malfunction and valve seat leakage. Always flush the piping

before installing the valve. *4: Do not use metal joints because they could damage the port. Use a PP or fluorine resin joint.

Wrap PTFE sealing tape two to thee times around the joint. Tighten the joint with the recommended tightening torque below. Recommended tightening torque: 0.10 to 0.15 N·m

*5: Do not use for hydrochloric acid, hydrofluoric acid, nitric acid or sodium hypochlorite (soda). *6: Keep leakage current from the control circuit within the levels below. *7: When standing the secondary piping, do not make it higher than 2 m. Use tubing or piping with the same or

larger bore size as the orifice to fix the pipe. *8: Do not disassemble the product.

MY DC12V

B Orifice

B M6

C Port size

D Rated voltage

� MYB1 (2 port)

: NC (normally closed) type

� MYG1 (3 port)

: universal type

OUT

COM

IN

NC NO

BG

2 port

3 port

B

DescriptionsSymbol

1 ø2

M6 M6

C

DC12VDC24VAC100V

12 VDC

24 VDC

100 VAC (50/60 Hz)

D

No. of port

Orifice

Port size

Rated voltage

1

A No. of portA

Page 11: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MYB1/MYG1 Series

780

Internal structure and parts list� MYB1-M6

� MYG1-M6

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

10

11

12

13

Coil assembly

Spring

Plunger

Diaphragm receiving

Protection seat

Diaphragm

Body

Mounting plate

Spring washer assembled cross headed pan head machine screw

Parts name

Class B molded coil

SUS304

SUS405

PPS

PTFE

FKM

PPS

SUS303

SUSXM7

Stainless steel

Stainless steel

Polyphenylene sulfide

Tetrafluoroethylene resin

Fluoro rubber

Polyphenylene sulfide

Stainless steel

Stainless steel

Material

Coil assembly

Spring

Plunger

Spacer

Diaphragm receiving

Protection seat

Diaphragm

Rod

Body

Spring holder

Spring

Mounting plate

Spring washer assembled cross headed pan head machine screw

Parts name

Class B molded coil

SUS304

SUY

PPS

PPS

PTFE

FKM

Ceramic

PPS

SUS304

SUS304

SUS303

SUSXM7

Stainless steel

Iron

Polyphenylene sulfide

Polyphenylene sulfide

Tetrafluoroethylene resin

Fluoro rubber

Polyphenylene sulfide

Stainless steel

Stainless steel

Stainless steel

Stainless steel

Material

123456789

No.

123456789

10111213

No.

Page 12: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MYB1/MYG1 Series

781

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

sC

ompa

ct m

edic

al fr

ee

Dimensions (Page 813)

� MYB1-M6

� MYG1-M6

O

MADE IN JAPAN

UT

14.5

56

ø26

ø26

OUTIN

300 (5)

Prepared hole depth 6 entrance ø82-M6 depth 5

2-M3 depth 6

15

COM M O

MADE IN JAPAN

N

COMNC NO

ø26

14.5

56

ø26

Prepared hole depth 6 entrance ø83-M6 depth 5

(5)300

2-M3 depth 6

15

Page 13: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

782

SpecificationsItem

Water, pure water, chemical liquids (fluids that do not corrode materials at wetted parts)

5 to 60

0 to 50 (no freezing)

Not in explosive or corrosive environment

0 (water pressure)

Rc1/8 (*4)

Equivalent to 3.0

0.18

Free

Continuous

24 VDC, 100 VAC (50/60 Hz)

-10 to +10% of rated voltage

5.5

1 or less

24 VDC: 1 or less, 100 VAC: 6 or less (*6)

B

MYB2-6 MYG2-6

JIS symbol

˚C˚C

cm3/min.

mm

kg

V

WA

mA

Working fluid

Fluid temperatureAmbient temperatureAtmosphereValve seat leakagePort sizeOrificeCv flow factorMounting attitudeWeightElectric specificationsRatingVoltageVoltage fluctuation rangePower consumptionRush currentLeakage currentHeat proof class

How to order

MPa

Conditions

COM positiveNC positiveNO positiveCOM negative

Fluid flow direction

COM → NO or NCNC → COMNO → COMNO or NC → COM

COM NC NOWorking pressure range of each port (MPa)

Conditions

IN positiveOUT positiveIN negative

Fluid flow direction

IN → OUTOUT → INOUT → IN

IN OUT0 to 0.20 to 0.1

-0.05 to 0

0 to 0.10 to 0.1

-0.05 to 0

Working pressure range of each port (MPa)

0.22 0.24

*1: Read the safety precautions for MYB2/MYG2 (page 768). *2: Before starting use, check the compatibility between the materials of the product and working fluid.

Working fluids must not adhere to the product body. *3: Foreign matter etc. inside the piping may cause malfunction and valve seat leakage. Always flush the piping

before installing the valve. *4: Do not use metal joints because they could damage the port. Use a PP or fluorine resin joint.

Wrap PTFE sealing tape two or three times around a joint which is compatible with the JIS B 0203 pipe taper screw.Tighten the joint with the recommended tightening torque below. Recommended tightening torque: 0.5 to 0.8 N·m

*5: Do not use for hydrochloric acid, hydrofluoric acid, nitric acid or sodium hypochlorite (soda). *6: Keep leakage current from the control circuit within the levels below. *7: When standing the secondary piping, do not make it higher than 2 m. Use tubing or piping with the same or

larger bore size as the orifice to fix the pipe. *8: Do not disassemble the product. *9: As this product, incorporating electronic oscillator circuits, generates noise, noise prevention should be taken

on the same power supply wire.

Working pressure range

0 to 0.20 to 0.10 to 0.1

-0.05 to 0

0 to 0.10 to 0.10 to 0.1

-0.05 to 0

0 to 0.10 to 0.10 to 0.1

-0.05 to 0

MY DC24V2 6

B Orifice

B

C Port size

D Rated voltage

� MYB2 (2 port)

: NC (normally closed) type

� MYG2 (3 port)

: universal type

OUT

COM

IN

NC NO

BG

2 port

3 port

A

DescriptionsSymbol

2 ø3

B

6 Rc1/8

DC24VAC100V

24 VDC

100 VAC (50/60 Hz)

C

D

No. of portA No. of port

Orifice

Port size

Rated voltage

Metal free 2, 3 port solenoid valve for chemical liquid

MYB2/MYG2 Series� NC (normally closed) type, universal type� Working fluid: water, pure water, chemical liquids� Port size: Rc1/8

Page 14: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MYB2/MYG2 Series

783

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

sC

ompa

ct m

edic

al fr

ee

Internal structure and parts list� MYB2 (2 port valve)

Cross headed pan head machine screw

Coil assembly

Spring

Plunger

Diaphragm receiving

Diaphragm

Protection seat

Parts name

SUSXM7

Class B mode coil

SUS304

SUS405

PPS

FKM

PTFE

Material

Stainless steel

Stainless steel

Stainless steel

Polyphenylene sulfide

Fluoro rubber

Tetrafluoroethylene resin

Body

Rod

Base

Spring holder

Spring

Mounting plate

Cap

Parts name

PPS

Ceramic

PPS

SUS304

SUS304

SUS304

PPS

Material

Polyphenylene sulfide

Polyphenylene sulfide

Stainless steel

Stainless steel

Stainless steel

Polyphenylene sulfide

� MYG2 (3 port valve)

1234567

No.89

1011121314

No.

MADE IN JAPAN

ORIFICEMPa

MADE IN JAPAN

ORIFICEMPa

1

2

3

4

5

6

7

8

13

1

2

3

4

5

6

7

89

10

11

12

13

14

Page 15: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MYB2/MYG2 Series

784

Dimensions (Page 813)

� MYB2 (2 port valve)

* When a set screw end in fixing holes 2-M5 is more than 6 mm from the bottom of the mounting plate, the screw cuts into the body or base, leading to cracking. The screw end must be 6 mm or less from the bottom of the mounting plate.

� MYG2 (3 port valve)

(8)30029.518.5

64

36

OUTIN

13.5

2-Rc1/8

28

18

9

(Screw section thickness 4)2-M5 depth 6*

OUT

>PPS<

9

74

(8)30029.518.5

NONC

36

COM

25

COM

28

3-Rc1/8

1818

18

(Screw section thickness 4)2-M5 depth 6*

NO

>PPS<

Page 16: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

Metal free 2, 3 port solenoid valve for chemical liquid

MYB3/MYG3 Series� NC (normally closed) type, universal type� Working fluid: water, pure water, chemical liquids� Port size: R1/8, R1/4, R3/8

785

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

sC

ompa

ct m

edic

al fr

ee

SpecificationsItem

Water, pure water, chemical liquids (fluids that do not corrode materials at wetted parts)

5 to 60

0 to 50 (no freezing)

Not in explosive or corrosive environment

0 (water pressure)

Rc1/8, Rc1/4, Rc3/8 (*4)

Equivalent to 5.0

0.5

Free

Continuous

12 VDC, 24 VDC, 100 VAC (50/60 Hz)

-10 to +10% of rated voltage

11

11.5

2 or less (12 VDC) / 1 or less (24 VDC) / 2 or less (100 VAC) (*6)

B

MYB3 MYG3

JIS symbol

˚C˚C

cm3/min.

mm

kg

ACDCmA

Working fluid

Fluid temperatureAmbient temperatureAtmosphereValve seat leakagePort sizeOrificeCv flow factorMounting attitudeWeightElectric specificationsRatingVoltageVoltage fluctuation rangePower consumption

Leakage currentHeat proof class

How to order

Working pressure range MPa

W

0.55 0.6

*1: Read the safety precautions for MYB3/MYG3 (page 768). *2: Before starting use, check the compatibility between the materials of the product and working fluid.

Working fluids must not adhere to the product body. *3: Foreign matter etc. inside the piping may cause malfunction and valve seat leakage. Always flush the piping

before installing the valve. *4: Do not use metal joints because they could damage the port. Use a PP or fluorine resin joint.

Wrap PTFE sealing tape two or three times around a joint which is compatible with the JIS B 0203 pipe taper screw.Tighten the joint with the recommended tightening torque below. Recommended tightening torque: Rc1/8: 0.5 to 0.8 N·m, Rc1/4 and Rc3/8: 1.0 to 1.5 N·m

*5: Do not use for hydrochloric acid, hydrofluoric acid, nitric acid or sodium hypochlorite (soda). *6: Keep leakage current from the control circuit within the levels below. *7: When standing the secondary piping, do not make it higher than 2 m. Use tubing or piping with the same or

larger bore size as the orifice to fix the pipe. *8: Do not disassemble the product.

Conditions

IN positiveOUT positiveIN negative

Fluid flow direction

IN → OUTOUT → INOUT → IN

IN OUT0 to 0.20 to 0.1

-0.05 to 0

0 to 0.10 to 0.1

-0.05 to 0

Working pressure range of each portConditions

COM positiveNC positiveNO positiveCOM negative

Fluid flow direction

COM → NO or NCNC → COMNO → COM

NO or NC → COM

COM NC NO0 to 0.20 to 0.10 to 0.1

-0.05 to 0

0 to 0.10 to 0.10 to 0.1

-0.05 to 0

0 to 0.10 to 0.10 to 0.1

-0.05 to 0

Working pressure range of each port

� MYB3 (2 port)

: NC (normally closed) type

� MYG3 (3 port)

: universal type

OUT

COM

IN

NC NO

B

Port sizeC

Rated voltageD

3 6 DC12V

Orifice

MY BDescriptionsSymbol

BG

2 port3 port

3 ø5

6810

Rc1/8Rc1/4Rc3/8

DC12VDC24VAC100V

12 VDC24 VDC100 VAC (50/60 Hz)

A No. of port A

B

C

D

Page 17: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MYB3/MYG3 Series

786

Internal structure and parts list� MYB3

� MYG3

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

7

8

9

10

11

15

12

13

14

Cross headed pan head machine screw

Coil assembly

Spring

Plunger

Diaphragm receiving

Diaphragm

Diaphragm receiving

Body

Mounting plate

Protection seat

Parts name

SUSXM7

Class B molded coil

SUS304

SUS405

PPS

FKM

PPS

PPS

SUS304

PTFE

Material

Cross headed pan head machine screw

Coil assembly

Spring

Plunger

Spacer

Diaphragm receiving

Diaphragm

Diaphragm receiving

Rod

Body

Base

Mounting plate

Spring holder

Spring

Protection seat

Parts name

SUSXM7

Class B molded coil

SUS304

SUS405

PPS

PPS

FKM

PPS

Ceramic

PPS

PPS

SUS304

SUS304

SUS304

PTFE

Material

Stainless steel

Stainless steel

Stainless steel

Polyphenylene sulfide

Fluoro rubber

Polyphenylene sulfide

Polyphenylene sulfide

Stainless steel

Tetrafluoroethylene resin

Stainless steel

Stainless steel

Stainless steel

Polyphenylene sulfide

Polyphenylene sulfide

Fluoro rubber

Polyphenylene sulfide

Polyphenylene sulfide

Polyphenylene sulfide

Stainless steel

Stainless steel

Stainless steel

Tetrafluoroethylene resin

123456789

10

No.

123456789

101112131415

No.

Page 18: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MYB3/MYG3 Series

787

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

sC

ompa

ct m

edic

al fr

ee

Dimensions (Page 813)

� MYB3

� MYG3<For AC>

<For AC> <For DC>

Rc1/8

Rc1/4

Rc3/8

MYB3-6MYB3-8MYB3-10

AModel no.

Rc1/8

Rc1/4

Rc3/8

MYG3-6MYG3-8MYG3-10

AModel no.

<For DC>

(8)300(26) (37.5)

86

20

OUT

50.5

IN

2-A

40

39

26

Thread length 10 or less2-M5

OUT

50.5

20

86

(8)30029.5(26)

Thread length 10 or less2-M5

26

IN OUT

(8)300(37.5)(26)

96

3-A

39

25

40

50.5

30

Thread length 10 or less2-M5

26

NONC COM

COM NO

96

30

26

Thread length 10 or less2-M5

(8)300

50.5

29.5(26)

NONC

COM

Page 19: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MYB3・MYG3 Series

788

SpecificationsItem

Water, pure water, chemical liquids (fluids that do not corrode materials at wetted parts)

0 to 60 (no freezing)

0 to 50 (no freezing)

Not in explosive or corrosive environment

0 (water pressure)

Rc1/8 (*4)

Equivalent to 3.0

0.18

Free

Continuous

24 VDC, 100 VAC (50/60 Hz)

-10 to +10% of rated voltage

5.5

24 VDC: 1 or less, 100 VAC: 6 or less (*6)

B

MEB2-6 MEG2-6

JIS symbol

˚C˚C

cm3/min.

mm

kg

V

WmA

Working fluid

Fluid temperatureAmbient temperatureAtmosphereValve seat leakagePort sizeOrificeCv flow factorMounting attitudeWeightElectric specificationsRatingVoltageVoltage fluctuation rangePower consumptionLeakage currentHeat proof class

How to order

Working pressure range

MPa

Conditions

COM positiveNC positiveNO positiveCOM negative

Fluid flow direction

COM → NO or NCNC → COMNO → COMNO or NC → COM

COM NC NOWorking pressure range of each portConditions

IN positiveOUT positiveIN negative

Fluid flow direction

IN → OUTOUT → INOUT → IN

IN OUT0 to 0.20 to 0.1

-0.05 to 0

0 to 0.10 to 0.1

-0.05 to 0

Working pressure range of each port

0.22 0.24

*1: Read the safety precautions for MEB2/MEG2 (page 768). *2: Before starting use, check the compatibility between the materials of the product and working fluid.

Working fluids must not adhere to the product body. *3: Foreign matter etc. inside the piping may cause malfunction and valve seat leakage. Always flush the piping

before installing the valve. *4: Do not use metal joints because they could damage the port. Use a PP or fluorine resin joint.

Wrap PTFE sealing tape two or three times around a joint which is compatible with the JIS B 0203 pipe taper screw.Tighten the joint with the recommended tightening torque below. Recommended tightening torque: 0.5 to 0.8 N·m

*5: Do not use for hydrochloric acid, hydrofluoric acid, nitric acid or sodium hypochlorite (soda). *6: Keep leakage current from the control circuit within the levels below. *7: When standing the secondary piping, do not make it higher than 2 m. Use tubing or piping with the same or

larger bore size as the orifice to fix the pipe. *8: Do not disassemble the product. *9: As this product, incorporating electronic oscillator circuits, generates noise, noise prevention should be taken

on the same power supply wire.

0 to 0.20 to 0.10 to 0.1

-0.05 to 0

0 to 0.10 to 0.10 to 0.1

-0.05 to 0

0 to 0.10 to 0.10 to 0.1

-0.05 to 0

ME DC24V2 6

B Orifice

B

C Port size

D Rated voltage

� MEB2 (2 port)

: NC (normally closed) type

� MEG2 (3 port)

: universal type

OUT

COM

IN

NCNO

BG

2 port

3 port

DescriptionsSymbol

No. of port

2 ø3

Orifice

6 Rc1/8

Port size

DC24VAC100V

24 VDC

100 VAC (50/60 Hz)

Rated voltage

A No. of portA

B

C

D

Metal free 2, 3 port solenoid valve for chemical liquid

MEB2/MEG2 Series� NC (normally closed) type, universal type� Working fluid: water, pure water, chemical liquids� Port size: Rc1/8

Page 20: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MEB2/MEG2 Series

789

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

sC

ompa

ct m

edic

al fr

ee

Internal structure and parts list� MEB2 (2 port valve)

Cross headed pan head machine screw

Coil assembly

Spring

Plunger

Diaphragm

O ring

Diaphragm receiving

Parts name

SUSXM7

Class B molded coil

SUS304

SUS405

PTFE

FKM

PPS

Material

Stainless steel

Stainless steel

Stainless steel

Tetrafluoroethylene resin

Fluoro rubber

Polyphenylene sulfide

Valve seat

Body

Mounting plate

Rod

Base

Spring holder

Spring

Parts name

Perfluoroelastomer

PPS

SUS304

Ceramic

PPS

SUS304

SUS304

Material

Polyphenylene sulfide

Stainless steel

Polyphenylene sulfide

Stainless steel

Stainless steel

1234567

No.89

1011121314

No.

MADE IN JAPAN

ORIFICEMPa

MADE IN JAPAN

ORIFICEMPa

� MEG2 (3 port valve)

2

1

1

3

4

5

6

7

10

8

9

3

2

9

8

4

5

6

7

11

12

13

14

10

Page 21: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

MEB2/MEG2 Series

790

Dimensions (Page 813)

� MEB2 (2 port valve)

* When a set screw end in fixing holes 2-M5 is more than 6 mm from the bottom of the mounting plate, the screw cuts into the body or base, leading to cracking. The screw end must be 6 mm or less from the bottom of the mounting plate.

� MEG2 (3 port valve)

(8)30029.518.5

64

36

OUTIN

13.5

2-Rc1/8

28

18

9

(Screw section thickness 4)2-M5 depth 6

OUT

>PPS<

(8)30029.518.5

NONC

36

COM

25

COM

28

3-Rc1/8

1818

18

(Screw section thickness 4)2-M5 depth 6

NO

>PPS<

9

74

Page 22: Medical analysis process components - BIBUS · MJB3 791 EMB21 793 EMB41/51 795 M 798 High corrosion resistant 2, 3 port valve UMB1/UMG1 805 2 port valve HB 807 Pinch valve 2, 3 port

813

Medical analysis process componentsElectronic Catalog file list

AP/AD

HNB/G

USB/G

FAB/G

FGB/G

FVB

FWB/G

FHB

FLB

AB

AG

CHB/G

MXB/G

SAB/SVB

HVB/HVL

Fordry air

NP/NAP/NVP

PD/FAD/PJ

CVE/CVSE

CPE/CPD

Customorder

Medicalanalysis

Other G.P.systems

APK/ADK

Explosionproof

Med

ical

ana

lysi

s pr

oces

s co

mpo

nent

s

Model no.Filename

MICRO CADAMDXFFolder name Filename (GROUP: CAD, USER: STDLIB)

Model no.Filename

MICRO CADAMDXFFolder name Filename (GROUP: CAD, USER: STDLIB)

Model no.Filename

MICRO CADAMDXFFolder name Filename (GROUP: CAD, USER: STDLIB)

Electronic Catalog file list is applied to "CAD DATA 2006".

� MAB1/MAG1: Page 778

� MEB2/MEG2: Page 790

� Lever type HMTB1/HMTG1: Page 804

� MJB3: Page 792

� 2, 3 port valve UMB1/UMG1: Page 806

� 2 port valve HB: Page 810

� MYB1/MYG1: Page 781

� MYB2/MYG2: Page 784

� MYB3/MYG3: Page 787

Medical analysis process components

Compact metal free 2, 3 port solenoid valve for chemical liquid

High corrosion resistant

Pinch valve (page 812)

CKD-MAB1-M6CKD-MAG1-M6

CKD-MYB1CKD-MYG1

CKD-MYB2-6CKD-MYG2-6

CKD-MYB3-6-ACCKD-MYB3-8-ACCKD-MYB3-10-ACCKD-MYB3-6-DCCKD-MYB3-8-DCCKD-MYB3-10-DCCKD-MYG3-6-ACCKD-MYG3-8-ACCKD-MYG3-10-ACCKD-MYG3-6-DCCKD-MYG3-8-DCCKD-MYG3-10-DC

CKD-MEB2-6CKD-MEG2-6

CKD-HMTB1CKD-HMTG1

CKD-MJB3-4TN

mab1_m6mag1_m6

myb1myg1

myb2_6myg2_6

myb3_6_acmyb3_8_acmyb3_10_acmyb3_6_dcmyb3_8_dcmyb3_10_dcmyg3_6_acmyg3_8_acmyg3_10_acmyg3_6_dcmyg3_8_dcmyg3_10_dc

meb2_6meg2_6

hmtb1hmtg1

mjb3_4tn

MA_

MY_

MY_2

MY_

ME_2

HMTBHMTG

MJB3

MAB1-M6MAG1-M6

MYB1MYG1

MYB2-6MYG2-6

MYB3-6-ACMYB3-8-ACMYB3-10-ACMYB3-6-DCMYB3-8-DCMYB3-10-DCMYG3-6-ACMYG3-8-ACMYG3-10-ACMYG3-6-DCMYG3-8-DCMYG3-10-DC

MEB2-6MEG2-6

HMTB1HMTG1

MJB3-4TN

CKD-UMB-T1CKD-UMG-T1

CKD-HB11CKD-HB21CKD-HB31-6(8)CKD-HB41-8-5CKD-HB41-8(10)

umb_t1umg_t1

hb11hb21hb31_6_8 hb41_8_5hb41_8_10

UMB_UMG

HB

UMB-T1UMG-T1

HB11HB21HB31-6(8)HB41-8-5HB41-8(10)

CKD-HYN-2CKD-HYN-3CKD-HYN-5CKD-HYN-8

hyn_2hyn_3hyn_5hyn_8

HYNHYN-2HYN-3HYN-5HYN-8