Workshop 3
Thermal Contact
WS 3-1ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
ANSYS Mechanical Heat Transfer
Workshop 3 - Thermal Contact
Training ManualProblem Description
• A set of electrical contacts is to be modeled in both an open an dclosed configuration.
– We’ll assume both parts are structural steel.
• While open, the heat load flows only through the “Arm” of theassembly.
• When closed, the contacts allow heat flow through the “Arm” a nd“Base”.
• The contacts are modeled with a gap, so we will use the contact
WS 3-2ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
• The contacts are modeled with a gap, so we will use the contactpinball control to simulate a closed contact configuration .
Base
ArmGap
Workshop 3 - Thermal Contact
Training ManualProblem Description
• Boundary Conditions:– Heat flux on end face of arm = 0.5 W/mm 2
– Temperature fixed on 2 bottom surfaces of base = 30 ºC– Convection on 5 faces on arm: h = 2e- 4 W/(mm 2* ºC)
• No convection on heat flux surface or circular cont act region.
– Convection on 8 faces on base: h = 4e -4 W/(mm 2* ºC)• No convection on 2 temperature surfaces or circular contact region.
WS 3-3ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
Workshop 3 - Thermal Contact
Training ManualUnits Setup
• Open Workbench and specify the unit system (Metric, kg, mm, s, ºC, mA, N, mV).
• Choose to “Display Values in Project Units”.
WS 3-4ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
Workshop 3 - Thermal Contact
Training ManualModel Setup
1. From the Workbench project page toolbox, select a Steady State Thermal analysis system.
WS 3-5ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
2. Right click the Geometry cell and import geometry “Contacts_WS3.x_t”.
3. Double click the Model cell to open the Mechanical application.
Workshop 3 - Thermal Contact
Training ManualModel Setup
4. When the import is complete you will notice that no contact has been defined. This is because the gap is larger than the default search tolerance. We begin by adding manual contact.
5. Highlight the “Connections” branch RMB > Insert > Manual
WS 3-6ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
branch RMB > Insert > Manual Contact Region.
6. Scope one circular face to the contact region and the other to the target (note, the order is unimportant in this example).
Workshop 3 - Thermal Contact
Training ManualModel Setup
7. In the Advanced contact details change the “Pinball Region” setting to “Radius”.– Recall from chapter 3 that, with bonded
and no separation contact, the pinball controls heat flow.
– As long as the contact and target surfaces are within the pinball radius, heat transfer can occur.
WS 3-7ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
heat transfer can occur.
8. Enter a pinball radius = 0.5 mm.• Note a sample pinball is displayed for
visual reference once a radius is entered.
Workshop 3 - Thermal Contact
Training ManualModel Setup
9. Highlight the “Steady State Thermal” branch and add boundary conditions as described:
10.Highlight the end face of the arm, RMB > Insert > Heat Flux.– Magnitude = 0.5 W/mm 2
WS 3-8ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
11.Highlight the 2 bottom surfaces of the base, RMB > Insert > Temperature.– Magnitude = 30 ºC
Workshop 3 - Thermal Contact
Training ManualModel Setup
12.Select 5 faces on the arm (top, bottom, both sides and the opposite end from where the heat flux was applied).
13.RMB > Insert > Convection– Film coefficient = 2e -4 W/(mm 2 * ºC)– Ambient Temperature = 30 ºC
14.Select the 8 faces on the rectangular
WS 3-9ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
14.Select the 8 faces on the rectangular section of the base (not the 2 ends where the temperature load is applied).
15.RMB > Insert > Convection– Film coefficient = 4e -4 W/(mm 2 * ºC)– Ambient Temperature = 30 ºC
Workshop 3 - Thermal Contact
Training ManualSolution
• Note, a default mesh is used of this example. In actual practice, always check the mesh quality and add mesh controls as needed.
WS 3-10ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
• Since we assume a steady state linear analysis, no analysis settings will be modified.
16.Solve
Workshop 3 - Thermal Contact
Training ManualPostprocessing
17.When the solution completes, drag and drop the temperature and both convection loads onto the Solution branch to setup reaction probes.
18.Evaluate All Results.• Note the reactions from both boundary
conditions on the base are essentially zero.
WS 3-11ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
• Note that the applied heat flux is 0.5 W/mm2 and the area of the face is 40 mm 2, which yields a total heat load of 20 W.
• Reaction on the arm convection = -20 W (steady state verification).
Workshop 3 - Thermal Contact
Training ManualPostprocessing
19.Add a temperature result and evaluate the result.– Note the temperature distribution within the
assembly. – As expected, no heat is flowing from the
arm to the base since the contact pinball is smaller than the geometric gap.
WS 3-12ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
• Next we will model a condition where the contacts are closed. While we could modify the geometry to close the gap, instead we will increase the pinball size to simulate the gap is closed. Continued on the next page.
Workshop 3 - Thermal Contact
Training ManualPostprocessing
20.Return to the schematic and highlight the top cell in the system, RMB > Rename.
21.Rename the system “Contact Open”.
WS 3-13ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
22.Again highlight the top cell in the system, RMB > Duplicate.
23.Repeat the steps above to rename the new system “Contacts Closed”.
Workshop 3 - Thermal Contact
Training ManualModel 2 Setup
24.Double click the Model cell in the “Contact Closed” system to open the new analysis.
WS 3-14ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
Workshop 3 - Thermal Contact
Training ManualModel 2 Setup
• Since the model is a duplicate of our original, only the contact needs to be changed.
25.Highlight the contact region and change the pinball radius to 1mm.
• The bonded contact type assumes closed contact whenever contact and target
WS 3-15ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
whenever contact and target faces are within the pinball. we can use this to simulate a closed contact condition here.
26.Solve.
Workshop 3 - Thermal Contact
Training Manual
• Again checking the reactions at the boundary conditions we can verify a steady state heat balance.
• RT = 2.3222 W, RC1 = 10.62 W, RC2 = 7.0582 W• RT + RC1 + RC2 = 20 W
Model 2 Postprocessing
WS 3-16ANSYS, Inc. Proprietary© 2009 ANSYS, Inc. All rights reserved.
August 2009Inventory #002667
– Note the temperature distribution now shows heat transfer from the contact arm to the base as expected.