6
Quick Reference Guide MDI Hybrid Implants

MDI Hybrid Implants

Embed Size (px)

Citation preview

Page 1: MDI Hybrid Implants

PM386 Rev06

IMTEC MDI™ Instruments & Accessories

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Quick Reference Guide

MDI Hybrid Implants

IMTEC Corporate OfficeIMTEC PLAZA

2401 North Commerce

Ardmore, Oklahoma 73401, USA

Tel: 580-223-4456

Toll Free: 800-879-9799

Fax: 800-986-9574 U.S.

Fax: 580-223-4561 International

IMTEC Latinoamérica, S.A. DE C.V.Rio Mayo 1219

Col. Vista Hermosa

Cuernavaca, Morelos

Mexico 62290

Tel: +52-(01)-777-316-4464

Toll Free: 01-800-006-4464

Fax: +52-(01)-777-316-0790

IMTEC United Kingdom Ltd.23 Clement Drive

Crewe, Cheshire CW13GN

Tel: +44-844-800-8983

Fax: +44-781-391-1372

IMTEC Canada155 Romina Drive

City of Vaughan, Ontario L4K 4Z9

Tel: 905-660-1838

Toll Free: 800-226-3220

Fax: 905-660-1905

IMTEC Los AlamosHYTEC Technology Center

110 Eastgate Drive

Los Alamos, New Mexico 87544, USA

Tel: 505-661-3000

Fax: 505-662-5179

IMTEC Europa, GmbHDornbachstraße 30

61440 Oberursel

Germany

Tel: +49 6171 88798-27

Toll Free: 00800 46833-000

Fax: +49 6171 88798-20

S1011

1030

S9032 8010 8040

S7007S7011S70158016

S9030

Site Preparation TitaniumLockingPliers

Drivers & Wrenches

MDI Ratchet Extension & Adapters

A B C

D

2010D

1.5mm Tissue Punch* S0150 MDI 1.1mm Surgical Drill* S1011MDI Drill Duo Kit* 2010DIncludes #2 Round Bur & 1.7mm Pilot Drill

Irrigated Drill Extender 2000

Site PreparationA

Titanium Locking Pliers 1030

SIG Drill Guide SIG-1000

MDI Finger Driver S9030MDI Winged Thumb Wrench S9032Ratchet Wrench 8010Extended Range Adjustable 8040Torque Wrench (20-70 Ncm)

Drivers & WrenchesC

Ratchet Extension - 16mm 8016MDI Ratchet Adapter - 13mm S7015MDI Ratchet Adapter - 9mm S7011MDI Ratchet Adapter - 5mm S7007

MDI Ratchet Extension & Adapters D

SECURE (Hard Pick-Up Kit) 8720SECURE Soft (Soft Reline Kit) 8120SECURE Dispensing Gun 8028Type II Extruder Gun

Insertion Tips 8366-10Type 1–10 Pack (not shown)

Mixing Tips 8448-1010 Pack (not shown)

Adhesive Brush 8449-1212 Pack (not shown)

SECURE Kits & AccessoriesF

*Provided sterile for single patient use

B

SIG Drill Guide

SIG-1000

E

E

IMTEC MDI Surgical Package & Hybrid Implant Add-ons:

Suggested add-ons for placement of MDI Hybrid Implant

8720

S1804

8120

8028

F MDI SECURE Kits & Accessories

MDI 1.1mm Surgical Drills, qty. 5 S1011Ratchet Wrench 8010Winged Thumb Wrench S9032Finger Driver S9030Ratchet Adapter-5mm S7007Ratchet Extension-16mm 8016Block Out Shims (pack of 25) S1010Titanium Locking Pliers 1030Surgical Box 1303SECURE Hard Pick-Up Kit 8720

MDI Drill Duo Kit 2010D 1.5mm Tissue Punch S0150

SECURE Dispensing Gun 8028ACCESS Toothbrush, bristle density #1, qty. 3 6008ACCESS Toothbrush, bristle density #2, qty. 3 6009IMTEC Dry Field System-Large, qty. 3 300-701IMTEC Dry Field System-Small 300-7003M ESPE ImpregumTM Soft Polyether Impression Material, Regular Set Intro Kit*

*For more information ordering 3M ESPE products visit www.3MESPE.com

S0150

2000

Page 2: MDI Hybrid Implants

MDI Hybrid Lab Analog Kits

MII-LAKOHybrid Lab Analog Kit

(O-Ball Abutment)

IMTEC MDI™ Hybrid Implant Surgical ProtocolSite Preparation

Implant Placement & Immediate Temporization

Dense Bone Drilling Protocol (D2 Bone) Entry divots are made with the #2 Round Bur. Pilot holes then made with the 1.7mm Pilot Drill should have a depth equal to approximately 1/2 the length of the planned implant plus the measurement of soft tissue thickness. An endodontic stopper is helpful in marking appropriate depth. Example: for a 13mm implant in a site with 2.5mm soft tissue thickness, a pilot hole of approx. 9mm is ideal (6.5mm + 2.5mm = 9mm)

S7007 8016 8010 8040Soft Bone Drilling Protocol (D3 Bone)

Entry divots are made with the #2 Round Bur. Then the 1.7mm Pilot Drill is used to perforate the cortical plate.

IMTEC 2.9mm MDI Implants are not recommended for placement in extremely dense (D1) or Soft (D4) bone.

2010D

MII-OB10MII-OB13MII-OB15MII-OB18

MII-T10MII-T13MII-T15MII-T18

O-Ball Abutment MDI 2.9mm Hybrid Implant

Tapered Abutment MDI 2.9mm Hybrid Implant

2920Tapered

Abutment Impression

Coping

2923Tapered

Abutment Immediate

Temporization Cap

2922Tapered

Abutment Waxing Coping

Tapered Abutment Copings

2921O-Ball

Impression Coping

2924O-Ball

Immediate Temporization

Cap

S4118O-Ball Waxing Coping

O-Ball Abutment Copings

S1010

Blockout Shim

MH-1

0550-01 0351-01

O-Rings

MH-2 MH-3

The Finger Driver begins insertion of the MDI 2.9mm Hybrid implant.

S9030

1 The Winged Thumb Wrench continues advancement of the implant.

S9032

MDI™ Hybrid Implants & Prosthetics

MII-LA MDI 2.9mm Hybrid

Lab Analog

MII-LA MII-LA2921 2924 2920 2923

O-Ball Abutment

Tapered Abutment

Pre-Surgical Steps: 1) Probe soft tissue at implant site & record tissue thickness. 2) Remove soft tissue at implant site using the 1.5mm tissue punch.

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Metal Housings

MII-LAKTHybrid Lab Analog Kit (Tapered Abutment)

The Ratchet Wrench or Extended Range Adjustable Torque Wrench and Ratchet Adapter will then finalize the insertion process.

A Pick-Up impression is made using the retentive Impression coping.

Remove the temporary restoration & cap (now bonded together) from the patient’s mouth. Let the material continue to cure in the matrix for a total of 5 minutes from the onset of mixing. Trim excess flash and remove oxygen inhibition layer with alcohol. Place the temporary restoration directly onto the implant abutment. RelyX™ Temporary Cement (Eugenol or Non-Eugenol) is optional due to the retentitive Clean & trim excess flash, then press temporary restoration in place directly on implant abutments. Cement is optional due to the retentive nature of the Immediate Temporization caps. If you need to add to the temporization material, you can use the shade matching Filtek™ Supreme Plus Flowable Restorative Material.

7

Final placement is achieved once all blasted surfaces are engaged in bone, and the crown margin is positioned at the appropriate level subgingivally.

2

3

4

5

6

IMPORTANT: IMTEC limited warranty and MDI limited warranty are applicable to all MDI Hybrid Implants.

Once adjacent teeth are lubricated with petroleum jelly, Tapered Abutment (2923) or O-Ball (2924) Immediate Temporization Caps are seated on the implants. Protemp™ Plus Temporization Material is then extruded in the temporary crown impression or stint and placed in the patient’s mouth for 1 minute and 40 seconds to 2 mintues and 50 seconds from the onset of mixing.

*For more information ordering 3M ESPE products visit www.3MESPE.com

Page 3: MDI Hybrid Implants

MDI Hybrid Lab Analog Kits

MII-LAKOHybrid Lab Analog Kit

(O-Ball Abutment)

IMTEC MDI™ Hybrid Implant Surgical ProtocolSite Preparation

Implant Placement & Immediate Temporization

Dense Bone Drilling Protocol (D2 Bone) Entry divots are made with the #2 Round Bur. Pilot holes then made with the 1.7mm Pilot Drill should have a depth equal to approximately 1/2 the length of the planned implant plus the measurement of soft tissue thickness. An endodontic stopper is helpful in marking appropriate depth. Example: for a 13mm implant in a site with 2.5mm soft tissue thickness, a pilot hole of approx. 9mm is ideal (6.5mm + 2.5mm = 9mm)

S7007 8016 8010 8040Soft Bone Drilling Protocol (D3 Bone)

Entry divots are made with the #2 Round Bur. Then the 1.7mm Pilot Drill is used to perforate the cortical plate.

IMTEC 2.9mm MDI Implants are not recommended for placement in extremely dense (D1) or Soft (D4) bone.

2010D

MII-OB10MII-OB13MII-OB15MII-OB18

MII-T10MII-T13MII-T15MII-T18

O-Ball Abutment MDI 2.9mm Hybrid Implant

Tapered Abutment MDI 2.9mm Hybrid Implant

2920Tapered

Abutment Impression

Coping

2923Tapered

Abutment Immediate

Temporization Cap

2922Tapered

Abutment Waxing Coping

Tapered Abutment Copings

2921O-Ball

Impression Coping

2924O-Ball

Immediate Temporization

Cap

S4118O-Ball Waxing Coping

O-Ball Abutment Copings

S1010

Blockout Shim

MH-1

0550-01 0351-01

O-Rings

MH-2 MH-3

The Finger Driver begins insertion of the MDI 2.9mm Hybrid implant.

S9030

1 The Winged Thumb Wrench continues advancement of the implant.

S9032

MDI™ Hybrid Implants & Prosthetics

MII-LA MDI 2.9mm Hybrid

Lab Analog

MII-LA MII-LA2921 2924 2920 2923

O-Ball Abutment

Tapered Abutment

Pre-Surgical Steps: 1) Probe soft tissue at implant site & record tissue thickness. 2) Remove soft tissue at implant site using the 1.5mm tissue punch.

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Metal Housings

MII-LAKTHybrid Lab Analog Kit (Tapered Abutment)

The Ratchet Wrench or Extended Range Adjustable Torque Wrench and Ratchet Adapter will then finalize the insertion process.

A Pick-Up impression is made using the retentive Impression coping.

Remove the temporary restoration & cap (now bonded together) from the patient’s mouth. Let the material continue to cure in the matrix for a total of 5 minutes from the onset of mixing. Trim excess flash and remove oxygen inhibition layer with alcohol. Place the temporary restoration directly onto the implant abutment. RelyX™ Temporary Cement (Eugenol or Non-Eugenol) is optional due to the retentitive Clean & trim excess flash, then press temporary restoration in place directly on implant abutments. Cement is optional due to the retentive nature of the Immediate Temporization caps. If you need to add to the temporization material, you can use the shade matching Filtek™ Supreme Plus Flowable Restorative Material.

7

Final placement is achieved once all blasted surfaces are engaged in bone, and the crown margin is positioned at the appropriate level subgingivally.

2

3

4

5

6

IMPORTANT: IMTEC limited warranty and MDI limited warranty are applicable to all MDI Hybrid Implants.

Once adjacent teeth are lubricated with petroleum jelly, Tapered Abutment (2923) or O-Ball (2924) Immediate Temporization Caps are seated on the implants. Protemp™ Plus Temporization Material is then extruded in the temporary crown impression or stint and placed in the patient’s mouth for 1 minute and 40 seconds to 2 mintues and 50 seconds from the onset of mixing.

*For more information ordering 3M ESPE products visit www.3MESPE.com

Page 4: MDI Hybrid Implants

MDI Hybrid Lab Analog Kits

MII-LAKOHybrid Lab Analog Kit

(O-Ball Abutment)

IMTEC MDI™ Hybrid Implant Surgical ProtocolSite Preparation

Implant Placement & Immediate Temporization

Dense Bone Drilling Protocol (D2 Bone) Entry divots are made with the #2 Round Bur. Pilot holes then made with the 1.7mm Pilot Drill should have a depth equal to approximately 1/2 the length of the planned implant plus the measurement of soft tissue thickness. An endodontic stopper is helpful in marking appropriate depth. Example: for a 13mm implant in a site with 2.5mm soft tissue thickness, a pilot hole of approx. 9mm is ideal (6.5mm + 2.5mm = 9mm)

S7007 8016 8010 8040Soft Bone Drilling Protocol (D3 Bone)

Entry divots are made with the #2 Round Bur. Then the 1.7mm Pilot Drill is used to perforate the cortical plate.

IMTEC 2.9mm MDI Implants are not recommended for placement in extremely dense (D1) or Soft (D4) bone.

2010D

MII-OB10MII-OB13MII-OB15MII-OB18

MII-T10MII-T13MII-T15MII-T18

O-Ball Abutment MDI 2.9mm Hybrid Implant

Tapered Abutment MDI 2.9mm Hybrid Implant

2920Tapered

Abutment Impression

Coping

2923Tapered

Abutment Immediate

Temporization Cap

2922Tapered

Abutment Waxing Coping

Tapered Abutment Copings

2921O-Ball

Impression Coping

2924O-Ball

Immediate Temporization

Cap

S4118O-Ball Waxing Coping

O-Ball Abutment Copings

S1010

Blockout Shim

MH-1

0550-01 0351-01

O-Rings

MH-2 MH-3

The Finger Driver begins insertion of the MDI 2.9mm Hybrid implant.

S9030

1 The Winged Thumb Wrench continues advancement of the implant.

S9032

MDI™ Hybrid Implants & Prosthetics

MII-LA MDI 2.9mm Hybrid

Lab Analog

MII-LA MII-LA2921 2924 2920 2923

O-Ball Abutment

Tapered Abutment

Pre-Surgical Steps: 1) Probe soft tissue at implant site & record tissue thickness. 2) Remove soft tissue at implant site using the 1.5mm tissue punch.

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Metal Housings

MII-LAKTHybrid Lab Analog Kit (Tapered Abutment)

The Ratchet Wrench or Extended Range Adjustable Torque Wrench and Ratchet Adapter will then finalize the insertion process.

A Pick-Up impression is made using the retentive Impression coping.

Remove the temporary restoration & cap (now bonded together) from the patient’s mouth. Let the material continue to cure in the matrix for a total of 5 minutes from the onset of mixing. Trim excess flash and remove oxygen inhibition layer with alcohol. Place the temporary restoration directly onto the implant abutment. RelyX™ Temporary Cement (Eugenol or Non-Eugenol) is optional due to the retentitive Clean & trim excess flash, then press temporary restoration in place directly on implant abutments. Cement is optional due to the retentive nature of the Immediate Temporization caps. If you need to add to the temporization material, you can use the shade matching Filtek™ Supreme Plus Flowable Restorative Material.

7

Final placement is achieved once all blasted surfaces are engaged in bone, and the crown margin is positioned at the appropriate level subgingivally.

2

3

4

5

6

IMPORTANT: IMTEC limited warranty and MDI limited warranty are applicable to all MDI Hybrid Implants.

Once adjacent teeth are lubricated with petroleum jelly, Tapered Abutment (2923) or O-Ball (2924) Immediate Temporization Caps are seated on the implants. Protemp™ Plus Temporization Material is then extruded in the temporary crown impression or stint and placed in the patient’s mouth for 1 minute and 40 seconds to 2 mintues and 50 seconds from the onset of mixing.

*For more information ordering 3M ESPE products visit www.3MESPE.com

Page 5: MDI Hybrid Implants

PM386 Rev06

IMTEC MDI™ Instruments & Accessories

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Quick Reference Guide

MDI Hybrid Implants

IMTEC Corporate OfficeIMTEC PLAZA

2401 North Commerce

Ardmore, Oklahoma 73401, USA

Tel: 580-223-4456

Toll Free: 800-879-9799

Fax: 800-986-9574 U.S.

Fax: 580-223-4561 International

IMTEC Latinoamérica, S.A. DE C.V.Rio Mayo 1219

Col. Vista Hermosa

Cuernavaca, Morelos

Mexico 62290

Tel: +52-(01)-777-316-4464

Toll Free: 01-800-006-4464

Fax: +52-(01)-777-316-0790

IMTEC United Kingdom Ltd.23 Clement Drive

Crewe, Cheshire CW13GN

Tel: +44-844-800-8983

Fax: +44-781-391-1372

IMTEC Canada155 Romina Drive

City of Vaughan, Ontario L4K 4Z9

Tel: 905-660-1838

Toll Free: 800-226-3220

Fax: 905-660-1905

IMTEC Los AlamosHYTEC Technology Center

110 Eastgate Drive

Los Alamos, New Mexico 87544, USA

Tel: 505-661-3000

Fax: 505-662-5179

IMTEC Europa, GmbHDornbachstraße 30

61440 Oberursel

Germany

Tel: +49 6171 88798-27

Toll Free: 00800 46833-000

Fax: +49 6171 88798-20

S1011

1030

S9032 8010 8040

S7007S7011S70158016

S9030

Site Preparation TitaniumLockingPliers

Drivers & Wrenches

MDI Ratchet Extension & Adapters

A B C

D

2010D

1.5mm Tissue Punch* S0150 MDI 1.1mm Surgical Drill* S1011MDI Drill Duo Kit* 2010DIncludes #2 Round Bur & 1.7mm Pilot Drill

Irrigated Drill Extender 2000

Site PreparationA

Titanium Locking Pliers 1030

SIG Drill Guide SIG-1000

MDI Finger Driver S9030MDI Winged Thumb Wrench S9032Ratchet Wrench 8010Extended Range Adjustable 8040Torque Wrench (20-70 Ncm)

Drivers & WrenchesC

Ratchet Extension - 16mm 8016MDI Ratchet Adapter - 13mm S7015MDI Ratchet Adapter - 9mm S7011MDI Ratchet Adapter - 5mm S7007

MDI Ratchet Extension & Adapters D

SECURE (Hard Pick-Up Kit) 8720SECURE Soft (Soft Reline Kit) 8120SECURE Dispensing Gun 8028Type II Extruder Gun

Insertion Tips 8366-10Type 1–10 Pack (not shown)

Mixing Tips 8448-1010 Pack (not shown)

Adhesive Brush 8449-1212 Pack (not shown)

SECURE Kits & AccessoriesF

*Provided sterile for single patient use

B

SIG Drill Guide

SIG-1000

E

E

IMTEC MDI Surgical Package & Hybrid Implant Add-ons:

Suggested add-ons for placement of MDI Hybrid Implant

8720

S1804

8120

8028

F MDI SECURE Kits & Accessories

MDI 1.1mm Surgical Drills, qty. 5 S1011Ratchet Wrench 8010Winged Thumb Wrench S9032Finger Driver S9030Ratchet Adapter-5mm S7007Ratchet Extension-16mm 8016Block Out Shims (pack of 25) S1010Titanium Locking Pliers 1030Surgical Box 1303SECURE Hard Pick-Up Kit 8720

MDI Drill Duo Kit 2010D 1.5mm Tissue Punch S0150

SECURE Dispensing Gun 8028ACCESS Toothbrush, bristle density #1, qty. 3 6008ACCESS Toothbrush, bristle density #2, qty. 3 6009IMTEC Dry Field System-Large, qty. 3 300-701IMTEC Dry Field System-Small 300-7003M ESPE ImpregumTM Soft Polyether Impression Material, Regular Set Intro Kit*

*For more information ordering 3M ESPE products visit www.3MESPE.com

S0150

2000

Page 6: MDI Hybrid Implants

PM386 Rev06

IMTEC MDI™ Instruments & Accessories

Orders and Customer Service: 800-879-9799 or 580-223-4456 Domestic Fax: 800-986-9574 or 580-223-4561 www.imtec.com Copyright 2009 IMTEC, a 3M Company

Quick Reference Guide

MDI Hybrid Implants

IMTEC Corporate OfficeIMTEC PLAZA

2401 North Commerce

Ardmore, Oklahoma 73401, USA

Tel: 580-223-4456

Toll Free: 800-879-9799

Fax: 800-986-9574 U.S.

Fax: 580-223-4561 International

IMTEC Latinoamérica, S.A. DE C.V.Rio Mayo 1219

Col. Vista Hermosa

Cuernavaca, Morelos

Mexico 62290

Tel: +52-(01)-777-316-4464

Toll Free: 01-800-006-4464

Fax: +52-(01)-777-316-0790

IMTEC United Kingdom Ltd.23 Clement Drive

Crewe, Cheshire CW13GN

Tel: +44-844-800-8983

Fax: +44-781-391-1372

IMTEC Canada155 Romina Drive

City of Vaughan, Ontario L4K 4Z9

Tel: 905-660-1838

Toll Free: 800-226-3220

Fax: 905-660-1905

IMTEC Los AlamosHYTEC Technology Center

110 Eastgate Drive

Los Alamos, New Mexico 87544, USA

Tel: 505-661-3000

Fax: 505-662-5179

IMTEC Europa, GmbHDornbachstraße 30

61440 Oberursel

Germany

Tel: +49 6171 88798-27

Toll Free: 00800 46833-000

Fax: +49 6171 88798-20

S1011

1030

S9032 8010 8040

S7007S7011S70158016

S9030

Site Preparation TitaniumLockingPliers

Drivers & Wrenches

MDI Ratchet Extension & Adapters

A B C

D

2010D

1.5mm Tissue Punch* S0150 MDI 1.1mm Surgical Drill* S1011MDI Drill Duo Kit* 2010DIncludes #2 Round Bur & 1.7mm Pilot Drill

Irrigated Drill Extender 2000

Site PreparationA

Titanium Locking Pliers 1030

SIG Drill Guide SIG-1000

MDI Finger Driver S9030MDI Winged Thumb Wrench S9032Ratchet Wrench 8010Extended Range Adjustable 8040Torque Wrench (20-70 Ncm)

Drivers & WrenchesC

Ratchet Extension - 16mm 8016MDI Ratchet Adapter - 13mm S7015MDI Ratchet Adapter - 9mm S7011MDI Ratchet Adapter - 5mm S7007

MDI Ratchet Extension & Adapters D

SECURE (Hard Pick-Up Kit) 8720SECURE Soft (Soft Reline Kit) 8120SECURE Dispensing Gun 8028Type II Extruder Gun

Insertion Tips 8366-10Type 1–10 Pack (not shown)

Mixing Tips 8448-1010 Pack (not shown)

Adhesive Brush 8449-1212 Pack (not shown)

SECURE Kits & AccessoriesF

*Provided sterile for single patient use

B

SIG Drill Guide

SIG-1000

E

E

IMTEC MDI Surgical Package & Hybrid Implant Add-ons:

Suggested add-ons for placement of MDI Hybrid Implant

8720

S1804

8120

8028

F MDI SECURE Kits & Accessories

MDI 1.1mm Surgical Drills, qty. 5 S1011Ratchet Wrench 8010Winged Thumb Wrench S9032Finger Driver S9030Ratchet Adapter-5mm S7007Ratchet Extension-16mm 8016Block Out Shims (pack of 25) S1010Titanium Locking Pliers 1030Surgical Box 1303SECURE Hard Pick-Up Kit 8720

MDI Drill Duo Kit 2010D 1.5mm Tissue Punch S0150

SECURE Dispensing Gun 8028ACCESS Toothbrush, bristle density #1, qty. 3 6008ACCESS Toothbrush, bristle density #2, qty. 3 6009IMTEC Dry Field System-Large, qty. 3 300-701IMTEC Dry Field System-Small 300-7003M ESPE ImpregumTM Soft Polyether Impression Material, Regular Set Intro Kit*

*For more information ordering 3M ESPE products visit www.3MESPE.com

S0150

2000