Expansion Joint Systems designed to protect appearances, so no one ever knows about your building’s war with Mother Nature. MasterFormat™ Division: 7 800.222.5556 | inprocorp.com/jointmaster

MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

  • Upload
    others

  • View
    10

  • Download
    4

Embed Size (px)

Citation preview

Page 1: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

Expansion Joint Systems designed to protect appearances, so no one ever knows about your building’s war with Mother Nature.

MasterFormat™ Division: 7

800.222.5556 | inprocorp.com/jointmaster

Page 2: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 3inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Need CEUs?Do you need a refresher on the intricacies of Expansion Joint Specifications? Our program will cover specifics, as well as installation challenges. Contact us today to setup a CEU presentation.

BIMJointMaster™ proudly offers one of the largest selections of Building Information Model (BIM) objects within the industry. Our extensive library is designed to give you the information you need for improving architectural concepts, collaboration, and precise construction. Download objects today at inprocorp.com/jointmaster.

Recycled Aluminum Expansion Joint SystemsExpansion joint frames and cover plates are extruded from aluminum containing an average of 75% pre-consumer and post-consumer recycled content.

Protect against Mother Nature At JointMaster™, we protect building appearances by covering up the endless war between buildings and Mother Nature. Our experts engineer joint solutions so that architects don't have to worry about compromised aesthetics.

� Floor Systems � Wall & Ceiling Systems � Exterior Joint Systems � Foam Seals � Fire Barriers

2

Page 3: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 5inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

System Type Series Models Joint Opening

Movement +/- Loading Class

Drywall Finishes – Pages 34-37

100 Series

101112113114611

1"-6"25mm – 150mm

25%-50% of Joint Width

N/A

Drywall Finishes, Flush Mount – Pages 38-40

200 Series223233243

2"-36"50mm – 900mm

50%-100% of Joint Width

N/A

Glide Plate – Pages 42-43

300 Series 300318

1"-6"25mm – 150mm

50%-100% of Joint Width

N/A

Centering Bar – Page 43

400 Series 481491

2"-24"50mm – 600mm

50%-100% of Joint Width

N/A

Surface Mount – Page 44

800 Series

811804104118

1"-6"25mm – 150mm

25%-100% of Joint Width

N/A

Acoustical Ceiling – Page 36

100 Series 1152"-4"

50mm – 100mm

50%-100% of Joint Width

N/A

Acoustical Ceiling – Page 35

800 Series 8211"-2"

25mm – 50 mm

50%-100% of Joint Width

N/A

System Type Series Models Joint Opening

Movement +/- Loading Class

Surface Mount, Flush Mount – Pages 10-15

100 Series

101103-110

120132/133

141

1"-3"25mm – 75mm

25% of Joint Width

Standard

Recessed Mount – Pages 16-17

200 Series221222223

2"-36"50mm – 900mm

25%-100% of Joint Width

StandardModerate

Glide Plate – Pages 18-19

300 Series

300304312320

2"-6"50mm – 150mm

50%-100% of Joint Width

Standard

Centering Bar – Pages 20-23

400 Series

401/421/423425/426/427428/430/432441/461/471

1"-8"25mm – 200mm

50%-100% of Joint Width

StandardModerate

Heavy Duty

Heavy Duty – Pages 24-26

700 Series

721/723725/741757/767

787

2"-12"50mm – 300mm

50%-100% of Joint Width

StandardModerate

Heavy Duty

Standard Cover Plate – Pages 27-29

800 Series801/802804/806807/808

1"-12"25mm – 300mm

25%-100% of Joint Width

StandardModerate

Single Sightline – Page 30

300 Series 3162"-6"

50mm – 150mm

50%-100% of Joint Width

ModerateHeavy Duty

Pan Systems – Page 31

500 Series 501502

2"-8"50mm – 200mm

50%-100% of Joint Width

ModerateHeavy Duty

Engineered Metal Products Engineered Metal Products

Wall and Ceiling Floor Systems

4

Page 4: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 7inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

System Type Series Models Joint Opening

Movement +/- Loading Class

Fire and Insulated Barriers – Page 55-57

900 Series900/920935/950975/990

1"-36"25.4mm – 914.4mm

25%-100% of Joint Width

2hr3hr4hr

Foam Seals – Pages 62

1100 Series110011501175

1"-12"25.4mm – 304.8mm

25%-100% of Joint Width

Standard

Foam Seals – Page 63

1200 Series 12001250

1/2"-20"12.7mm –

508mm

25%-100% of Joint Width

N/A

System Type Series Models Joint Opening

Movement +/- Loading Class

Surface Mount – Pages 48-49

600 Series 601651

2"-24"50mm – 600mm

50%-100% of Joint Width

N/A

Seal Systems – Pages 50-51

600 Series

615616620621

2"-36"50mm – 600mm

50%-100 of Joint Width

N/A

Bellow System – Page 53

600 Series 672674

2"-36"50mm – 900 mm

50%-100% of Joint Width

N/A

Metal Roofing System – Pages 54

600 Series 651691

2"-8"50mm – 200mm

50% of Joint Width

N/A

Parking and Open Structure – Pages 59-60

1000 SeriesARBRCR

1"-4"25mm – 100mm

25%-50% of Joint Width

Heavy Duty

Engineered Metal Products Engineered Metal Products

Exterior Joint Systems Fire Barriers, Foam Seals

Many custom finishes are available for the Standard Expansion Joint Systems. Finish options include anodized, Kynar® (PVDF) paint, powder coat, primer and brushed finishes.

Anodized Finishes

Custom Paint Finishes

Premier Colors

Available Colors

Standard Seal Colors

Patine GreenSlate Gray

Black

Dark Ivy

Silver

Light Seawolf Beige

Sage Brown

Burnt Sun

Colonial Red

Carnival Red II

Dove Gray

Quaker BronzeMilitary

Blue

Champagne Pearl

Sierra TanIvory

Charcoal Gray

Interstate Blue

Classic Copper

Beige

Boysenberry

SandstoneBone White

Hartford Green

Pewter

Clear Champagne

Light Bronze

Medium Bronze

Dark Bronze

Extra Dark Bronze Black

Off White Bright WhiteGray BeigeBlackAvailable Finishes

6

Page 5: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 9inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

JointMaster™ offers a variety of Floor Systems for both

Thermal and Seismic applications. Featuring minimal

sightlines and high load ratings, JointMaster Floor

Systems are designed to do the job right while barely

being noticed.

Floor SystemsModel Number Guide

Loading Definitions

Standard / Moderate / and Heavy are designations as they relate to load ratings. These are provided as a guideline to assist in making a preliminary product selection for a given application.

� “Standard” suggests use in common applications such as typical office settings or other spaces where pedestrian traffic or occasional rubber-wheeled traffic like mail carts and light-weight cleaning equipment, luggage, etc. is the norm.

� “Moderate” suggests applications where occasional heavier maintenance equipment with soft rubber tires (scissor lifts, motorized cleaning equipment, etc.) would be added to the standard traffic. The systems in this category are comprised of heavier aluminum extrusions, with thicker walled extruded rubber inserts.

� “Heavy” is for applications where truly heavy loads (such as vehicles), or high-point loads (gurneys, mobile medical equipment, coin carts, materials handling equipment, etc.) are the norm. these heavy duty systems. They are capable of multi-directional movements and are also available in surface or blockout mounted variations.

� Contact your JointMaster™ representative for more details on project specific leading conditions.

Series | Model 100 Elastomeric Seal Systems for Floors / Walls / Ceilings200 Dual Elastomeric Seal Systems for Floors / Walls / Ceilings300 Glide Plate Seismic Systems for Floors / Walls / Ceilings400 Center Bar Seismic Systems for Floors / Walls / Ceilings500 Seismic “Pop-up” Systems for Floors and Walls600 Exterior Seismic Systems for Walls and Roofs700 Heavy Duty Seismic Systems for Floors800 Cover Plate Systems for Floors / Walls / Ceilings900 Fire Barrier Systems1000 Exterior Compression Seals1100 Foam Seals1200 Silicone Foam Seals

LocationA01 Floor to FloorA02 Floor to WallA07 Wall to Wall or Ceiling to CeilingA09 Wall to Corner or Ceiling to WallA18 Ceiling to Wall for Acoustical Ceiling SystemsA24 Ceiling to Ceiling for Acoustical Ceiling SystemsG01 Curb to Curb or Roof to RoofG02 Curb to Wall or Roof to Wall

Joint Width025 1” (25mm)038 1½” (38mm)050 2” (51mm)075 3” (76mm)100 4” (102mm)150 6” (150mm)200 8” (200mm)300 12” (300mm)350 14” (350mm)

400 16” (400mm)450 18” (450mm)500 20” (500mm)600 24” (600mm)

Series/ ModelNumber

Condition JointWidth

JOINTWIDTH

CONDITION

FRAMEHEIGHT

SEAL COLOR

101 - A01 - 025

8

Page 6: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 11inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Surface Mount

Floor Systems

103 Series – VCT

Surface mount design makes systems ideal for renovations.

100 Series systems allow for Standard loading conditions such as offices, restaurants, cafeterias, and clean rooms.

� Dual durometer seal provides secure fit and optimal flexibility. � Frames adaptable to multiple floor finishes including concrete,

VCT, sheet vinyl and carpet. � Snap-fit design for easy on-site assembly. � Optional integral vapor barrier available. � Seamlessly integrates with the following wall and ceiling systems:

� 101-A07/A09 � 104-A07/A09 � 112-A07/A09 � 113-A07/A09 � 118-A07/A09

� Mill finish standard. � Standard and custom seal colors available, see page 7.

% OF MOVEMENT±25%

VAPOR BARRIERoptional

JOINT WIDTH1" (25mm) – 3" (76mm)

FIRE RATEDoptional

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

103-A01-025 1" 25 5/8" 16 1/8" 4 4" 102 * * 1/4" 6 1/4" 6103-A01-038 1 1/2" 38 5/8" 16 1/8" 4 4 1/2" 114 * * 3/8" 10 3/8" 10103-A01-050 2" 51 1" 25 1/8" 4 4 7/8" 124 * * 1/2" 13 1/2" 13103-A01-075 3" 76 1 1/8" 28 1/8" 4 6" 152 * * 3/4" 19 3/4" 19

Floor to Wall

103-A02-025 1" 25 5/8" 16 1/8" 4 2 1/2" 64 * * 1/4" 6 1/4" 6103-A02-038 1 1/2" 38 5/8" 16 1/8" 4 2 15/16" 75 * * 3/8" 10 3/8" 10103-A02-050 2" 51 1" 25 1/8" 4 3 3/8" 86 * * 1/2" 13 1/2" 13103-A02-075 3" 76 1 1/8" 28 1/8" 4 4 1/2" 114 * * 3/4" 19 3/4" 19

S

W

H1H2

S

H1

W

H2112"

A02 Floor/Wall (2" (51mm) system shown)

A01 Floor/Floor (2" (51mm) system shown)

104 Series – Sheet Vinyl or Concrete

105 Series – Sheet Vinyl

106 Series – Carpet

Not available online: A02-025, A02-050

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor106-A01-025 1" 25 5/8" 16 1/4" 6 1" 25 * * 1/4" 6 1/4" 6106-A01-038 1 1/2" 38 5/8" 16 1/4" 6 1 1/2" 36 * * 3/8" 10 3/8" 10106-A01-050 2" 51 1" 25 1/4" 6 2" 47 * * 1/2" 13 1/2" 13106-A01-075 3" 76 1 1/8" 28 1/4" 6 3" 73 * * 3/4" 19 3/4" 19

Floor to Wall106-A02-025 1" 25 5/8" 16 1/4" 6 1" 25 * * 1/4" 6 1/4" 6106-A02-038 1 1/2" 38 5/8" 16 1/4" 6 1 1/2" 36 * * 3/8" 10 3/8" 10106-A02-050 2" 51 1" 25 1/4" 6 2" 47 * * 1/2" 13 1/2" 13106-A02-075 3" 76 1 1/8" 28 1/4" 6 3" 73 * * 3/4" 19 3/4" 19

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor104-A01-025 1" 25 5/8" 16 * * 4 3/4" 121 * * 1/4" 6 1/4" 6104-A01-038 1 1/2" 38 5/8" 16 * * 5 1/8" 131 * * 3/8" 10 3/8" 10104-A01-050 2" 51 1" 25 * * 5 5/8" 143 * * 1/2" 13 1/2" 13104-A01-075 3" 76 1 1/8" 28 * * 6 5/8" 169 * * 3/4" 19 3/4" 19

Floor to Wall104-A02-025 1" 25 5/8" 16 * * 2 7/8" 73 * * 1/4" 6 1/4" 6104-A02-038 1 1/2" 38 5/8" 16 * * 3 5/16" 84 * * 3/8" 10 3/8" 10104-A02-050 2" 51 1" 25 * * 3 3/4" 95 * * 1/2" 13 1/2" 13104-A02-075 3" 76 1 1/8" 28 * * 4 3/4" 121 * * 3/4" 19 3/4" 19

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor105-A01-025 1" 25 5/8" 16 1/8" 3 1" 25 * * 1/4" 6 1/4" 6105-A01-038 1 1/2" 38 5/8" 16 1/8" 3 1 1/2" 36 * * 3/8" 10 3/8" 10105-A01-050 2" 51 1" 25 1/8" 3 2" 47 * * 1/2" 13 1/2" 13105-A01-075 3" 76 1 1/8" 28 1/8" 3 3" 73 * * 3/4" 19 3/4" 19

Floor to Wall105-A02-025 1" 25 5/8" 16 1/8" 3 1" 25 * * 1/4" 6 1/4" 6105-A02-038 1 1/2" 38 5/8" 16 1/8" 3 1 1/2" 36 * * 3/8" 10 3/8" 10105-A02-050 2" 51 1" 25 1/8" 3 2" 47 * * 1/2" 13 1/2" 13105-A02-075 3" 76 1 1/8" 28 1/8" 3 3" 73 * * 3/4" 19 3/4" 19

A01 Floor/Floor (2" (51mm) system shown)

S

W

H1

A02 Floor/Wall (2" (51mm) system shown)

A01 Floor/Floor (2" (51mm) system show)

S

W

H1 H2

A02 Floor/Wall (2" (51mm) system shown)

A01 Floor/Floor (2" (51mm) system shown)

SH2

W

H1

A02 Floor/Wall (2" (51mm) system shown)

H1

W

112"

10

Page 7: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 13inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Flush, Recessed

Floor Systems

A01 Floor/Floor (2" (51mm) system shown)

� Surface mount design makes systems ideal for renovations (132, 133, 141 systems).

� Dual durometer seal provides secure fit and optimal flexibility. � Snap-fit design for easy on-site assembly. � Optional integral vapor barrier (101 system) slides directly into

frame for easy installation. � Seamlessly integrates with the following wall and

ceiling systems: � 101-A07/A09 � 112-A07/A09 � 113-A07/A09 � 118-A07/A09

� Mill finish standard. � Standard and custom seal colors available, see page 7.

132 – Sheet Vinyl133 – Carpet Series

141 Series – Carpet and VCT

120 Series – Any Floor Type

A01 Floor/Floor 2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor141-A01-025 1" 25 5/8" 16 * * 5 5/8" 142 2 3/4" 70 1/4" 6 1/4" 6141-A01-038 1 1/2" 35 5/8" 16 * * 6" 153 2 3/4" 70 3/8" 10 3/8" 10141-A01-050 2" 50 5/8" 16 * * 6 1/2" 164 2 3/4" 70 1/2" 13 1/2" 13

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

132-A01-050 2" 50 5/8" 16 1/8" 3 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13132-A01-075 3" 75 5/8" 16 1/8" 3 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13133-A01-050 2" 50 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13133-A01-075 3" 75 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13

Floor to Wall

132-A02-050 2" 50 5/8" 16 1/8" 3 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13132-A02-075 3" 75 5/8" 16 1/8" 3 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13133-A02-050 2" 50 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13133-A02-075 3" 75 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13

S

W

H1

S

WH1

A02 Floor/Wall (1" (25mm) system shown)

S

W

H1

133-A01 Floor/Floor 2" (51mm) system shown)

132-A02 Floor/Wall2" (51mm) system shown)

S

W

H1 H2

H2S

W

H1

Flush mount frames adaptable to any floor finish.100 Series systems ideal for Standard loading conditions such as those encountered in showrooms, restrooms, and lobbies.

101 Series – Any Floor Type

A01 Floor/Floor 1" (25mm) system shown)

A02 Floor/Wall 1" (25mm) system shown)

% OF MOVEMENT±25%

VAPOR BARRIERoptional

JOINT WIDTH1" (25mm) – 3" (76mm)

FIRE RATEDoptional

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

101-A01-025 1" 25 1 1/2" 38 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6101-A01-038 1 1/2" 38 1 1/2" 38 * * 1 7/16" 36 2 1/2" 64 3/8" 10 3/8" 10101-A01-050 2" 51 1 1/2" 38 * * 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13101-A01-075 3" 76 1 1/2" 38 * * 2 7/8" 73 2 1/2" 64 3/4" 19 3/4" 19

Floor to Wall

101-A02-025 1" 25 1 1/2" 38 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6101-A02-038 1 1/2" 38 1 1/2" 38 * * 1 7/16" 36 2 1/2" 64 3/8" 10 3/8" 10101-A02-050 2" 51 1 1/2" 38 * * 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13101-A02-075 3" 76 1 1/2" 38 * * 2 7/8" 73 2 1/2" 64 3/4" 19 3/4" 19

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

120-A01-025 1 " 25 1"-1 1/2"-2" 25-38-50 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6

120-A01-038 1 1/2" 38 1"-1 1/2"-2" 25-38-50 * * 1 3/8" 35 2 1/2" 64 3/8" 10 3/8" 10

120-A01-050 2" 50 1"-1 1/2"-2" 25-38-50 * * 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13

Floor to Wall120-A02-025 1" 25 1"-1 1/2"-2" 25-38-50 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6

120-A02-038 1 1/2" 38 1"-1 1/2"-2" 25-38-50 * * 1 3/18" 36 2 1/2" 64 3/8" 10 3/8" 10

120-A02-050 2" 50 1"-1 1/2"-2" 25-38-50 * * 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

12

Page 8: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 15inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

New to Existing

Floor Systems

� Dual durometer seal provides secure fit and optimal flexibility. � Snap-fit design allows easy on-site assembly. � Optional integral vapor barrier slides directly into frame for

easy installation. � Seamlessly integrates with the following wall and ceiling

systems: � 101-A07/A09 � 104-A07/A09 � 112-A07/A09 � 113-A07/A09

� Mill finish standard. � Standard and custom seal colors available, see page 7.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

107-A01-025 1" 25 1 1/2" 38 * * 2 7/8" 73 2 1/2" 64 1/4" 6 1/4" 6107-A01-038 1 1/2" 38 1 1/2" 38 * * 3 5/16" 84 2 1/2" 64 3/8" 10 3/8" 10107-A01-050 2" 51 1 1/2" 38 * * 3 3/4" 95 2 1/2" 64 1/2" 13 1/2" 13107-A01-075 3" 76 1 1/2" 38 * * 4 3/4" 121 2 1/2" 64 3/4" 19 3/4" 19

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

107 Series – Finished Concrete A01 Floor/Floor (1" (25mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

108-A01-025 1" 25 1 1/2" 38 1/8" 3 1" 25 2 1/2" 64 1/4" 6 1/4" 6108-A01-038 1 1/2" 38 1 1/2" 38 1/8" 3 1 1/2" 36 2 1/2" 64 3/8" 10 3/8" 10

108-A01-050 2" 51 1 1/2" 38 1/8" 3 2' 47 2 1/2" 64 1/2" 13 1/2" 13

108-A01-075 3" 76 1 1/2" 38 1/8" 3 3" 73 2 1/2" 64 3/4" 19 3/4" 19

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

109-A01-025 1" 25 1 1/2" 38 1/4" 6 1" 25 2 1/2" 64 1/4" 6 1/4" 6109-A01-038 1 1/2" 38 1 1/2" 38 1/4" 6 1 1/2" 36 2 1/2" 64 3/8" 10 3/8" 10109-A01-050 2" 51 1 1/2" 38 1/4" 6 2" 47 2 1/2" 64 1/2" 13 1/2" 13109-A01-075 3" 76 1 1/2" 38 1/4" 6 3" 73 2 1/2" 64 3/4" 19 3/4" 19

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

110-A01-025 1" 25 1 1/2" 38 1/8" 4 2 1/2" 64 2 1/2" 64 1/4" 6 1/4" 6110-A01-038 1 1/2" 38 1 1/2" 38 1/8" 4 2 5/16" 75 2 1/2" 64 3/8" 10 3/8" 10110-A01-050 2" 51 1 1/2" 38 1/8" 4 3 3/8" 86 2 1/2" 64 1/2" 13 1/2" 13110-A01-075 3" 76 1 1/2" 38 1/8" 4 4 1/2" 113 2 1/2" 64 3/4" 19 3/4" 19

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

108 Series – Sheet Vinyl

109 Series – Carpet

110 Series – VCT

Not available online: A01-038

S

W

H1

A01 Floor/Floor (1" (25mm) system shown)

A01 Floor/Floor (1" (25mm) system shown) S

W

H1H2

A01 Floor/Floor (2" (51mm) system shown) S

W

H1H2

Designed for retrofits, additions and renovations where blockout occurs on one side only.100 systems allow for Standard loading conditions such as offices, cafeterias, and clean rooms.

% OF MOVEMENT±25%

VAPOR BARRIERoptional

JOINT WIDTH1" (25mm) – 3" (76mm)

FIRE RATEDoptional

S

W

H2H1

14

Page 9: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 17inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Recessed Mount

Floor Systems

� Recessed mount frames for minimal sightline, adaptable with many floor finishes.

� Dual durometer seal provides secure fit and optimal flexibility. � Double seals absorb limited serviceable seismic movement. � Seamlessly integrates with the following wall and

ceiling systems: � 101-A07/A09 � 112-A07/A09 � 113-A07/A09

� Mill finish standard. � Standard and custom seal colors available, see page 7.

221 Series – Any Flooring TypeFlush

A01 Floor/Floor (4" (100mm) system shown)

222 Series – VCT

223 Series – Tile or Carpet (3/8"/10mm)

A01 Floor/Floor for VCT 4" (100mm) system shown)

A01 Floor/Floor for 3/8" (10mm) Floor Finishes (4" (100mm) system shown)

Snap-fit design for easy on-site assembly.200 Series systems allow for Moderate loading applications while meeting a wide range of joint sizes.

Application SystemW H1 S B Movement +/-

Joint Width Frame Height 1 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm

Floor to Floor

221-A01-050 2" 51 5/8" 16 4 7/8" 124 1 1/2" 13 1/2" 13 1/2" 13221-A01-100 4" 102 5/8" 16 9 3/8" 238 2 3/4" 70 1" 25 1" 25221-A01-150 6" 152 5/8" 16 11 3/8" 289 2 3/4" 70 1" 25 1" 25221-A01-200 8" 200 5/8" 16 18" 457 4 1/2" 114 4 100 4 100221-A01-250 10" 250 5/8" 16 21" 533 4 1/2" 114 5 125 5 125221-A01-300 12" 300 5/8" 16 24" 609 4 1/2" 114 6 150 6 150221-A01-350 14" 350 5/8" 16 27" 686 4 1/2" 114 7 175 7 175221-A01-400 16" 400 5/8" 16 30" 762 4 1/2" 114 8 200 8 200221-A01-450 18" 450 5/8" 16 33" 838 4 1/2" 114 9 225 9 225

Floor to Wall

221-A02-050 2" 51 5/8" 16 3 1/2" 89 1 1/2" 13 1/4" 6 1/4" 6221-A02-100 4" 102 5/8" 16 6 5/8" 168 2 3/4" 70 1/2" 13 1/2" 13221-A02-150 6" 152 5/8" 16 8 5/8" 219 2 3/4" 70 1/2" 13 1/2" 13221-A02-200 8" 200 5/8" 16 13" 330 4 1/2" 114 4 100 4 100221-A02-250 10" 250 5/8" 16 15 1/2" 394 4 1/2" 114 5 125 5 125221-A02-300 12" 300 5/8" 16 18" 457 4 1/2" 114 6 150 6 150221-A02-350 14" 350 5/8" 16 20 1/2" 521 4 1/2" 114 7 175 7 175221-A02-400 16" 400 5/8" 16 23" 584 4 1/2" 114 8 200 8 200221-A02-450 18" 450 5/8" 16 25 1/2" 648 4 1/2" 114 9 225 9 225

Larger sizes available

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

222-A01-050 2" 51 5/8" 16 1/8" 3 2" 51 1 1/2" 13 1/2" 13 1/2" 13222-A01-100 4" 102 5/8" 16 1/8" 3 4" 102 2 3/4" 70 1" 25 1" 25222-A01-150 6" 152 5/8" 16 1/8" 3 4" 102 2 3/4" 70 1" 25 1" 25222-A01-200 8" 200 5/8" 16 1/8" 3 6" 152 4 1/2" 114 4 100 4 100222-A01-250 10" 250 5/8" 16 1/8" 3 6" 152 4 1/2" 114 5 125 5 125222-A01-300 12" 300 5/8" 16 1/8" 3 6" 152 4 1/2" 114 6 150 6 150222-A01-350 14" 350 5/8" 16 1/8" 3 6" 152 4 1/2" 114 7 175 7 175222-A01-400 16" 400 5/8" 16 1/8" 3 6" 152 4 1/2" 114 8 200 8 200222-A01-450 18" 450 5/8" 16 1/8" 3 6" 152 4 1/2" 114 9 225 9 225

Floor to Wall

222-A02-050 2" 51 5/8" 16 1/8" 3 1" 25 1 1/2" 13 1/4" 6 1/4" 6222-A02-100 4" 102 5/8" 16 1/8" 3 2" 51 2 3/4" 70 1/2" 13 1/2" 13222-A02-150 6" 152 5/8" 16 1/8" 3 2" 51 2 3/4" 70 1/2" 13 1/2" 13222-A02-200 8" 200 5/8" 16 1/8" 3 3" 152 4 1/2" 114 4 100 4 100222-A02-250 10" 250 5/8" 16 1/8" 3 3" 152 4 1/2" 114 5 125 5 125222-A02-300 12" 300 5/8" 16 1/8" 3 3" 152 4 1/2" 114 6 150 6 150222-A02-350 14" 350 5/8" 16 1/8" 3 3" 152 4 1/2" 114 7 175 7 175222-A02-400 16" 400 5/8" 16 1/8" 3 3" 152 4 1/2" 114 8 200 8 200222-A02-450 18" 450 5/8" 16 1/8" 3 3" 152 4 1/2" 114 9 225 9 225

Larger sizes available

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

223-A01-050 2" 51 5/8" 16 3/8" 10 2" 51 1 1/2" 13 1/2" 13 1/2" 13223-A01-100 4" 102 5/8" 16 3/8" 10 4" 102 2 3/4" 70 1" 25 1" 25223-A01-150 6" 152 5/8" 16 3/8" 10 4" 102 2 3/4" 70 1" 25 1" 25223-A01-200 8" 200 5/8" 16 1/4" 7 6" 152 4 1/2" 114 4 100 4 100223-A01-250 10" 250 5/8" 16 1/4" 7 6" 152 4 1/2" 114 5 125 5 125223-A01-300 12" 300 5/8" 16 1/4" 7 6" 152 4 1/2" 114 6 150 6 150223-A01-350 14" 350 5/8" 16 1/4" 7 6" 152 4 1/2" 114 7 175 7 175223-A01-400 16" 400 5/8" 16 1/4" 7 6" 152 4 1/2" 114 8 200 8 200223-A01-450 18" 450 5/8" 16 1/4" 7 6" 152 4 1/2" 114 9 225 9 225

Floor to Wall

223-A02-050 2" 51 5/8" 16 3/8" 10 1" 25 1 1/2" 13 1/4" 6 1/4" 6223-A02-100 4" 102 5/8" 16 3/8" 10 2" 51 2 3/4" 70 1/2" 13 1/2" 13223-A02-150 6" 152 5/8" 16 3/8" 10 2" 51 2 3/4" 70 1/2" 13 1/2" 13223-A02-200 8" 200 5/8" 16 1/4" 7 3" 76 4 1/2" 114 4 100 4 100223-A02-250 10" 250 5/8" 16 1/4" 7 3" 76 4 1/2" 114 3 125 3 125223-A02-300 12" 300 5/8" 16 1/4" 7 3" 76 4 1/2" 114 6 150 6 150223-A02-350 14" 350 5/8" 16 1/4" 7 3" 76 4 1/2" 114 7 175 7 175223-A02-400 16" 400 5/8" 16 1/4" 7 3" 76 4 1/2" 114 8 200 8 200223-A02-450 18" 450 5/8" 16 1/4" 7 3" 76 4 1/2" 114 9 225 9 225

Larger sizes available

% OF MOVEMENT±50%

VAPOR BARRIERoptional

JOINT WIDTH2 " (50mm – 6" (150mm)

FIRE RATEDoptional

S

W

H1

S

W

H1 H2

S

W

H1 H2

16

Page 10: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 19inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

S

W

H1

H2Glide Plate

Floor Systems

Glide plate cover provides a smooth and durable transition over expansion joints. 300 Series systems meet Standard to Moderate loading conditions, are seismic-capable, and have unlimited shear movement. Ideal for public areas such as schools, civic centers and airports.

320 Series – New to Existing � Designed for retrofits, additions and renovations where blockout

occurs on one side only. � Optional integral vapor barrier slides directly into frame for

easy installation.

304 Series – Recessed Mount/VCT � 1/8" (3mm) nosing designed specifically for vinyl floors.

312 Series – Recessed Mount � Surface mount flanges conceal damaged flooring edges.

300 Series – Recessed Mount � Smooth transition ideal for rolling carts. � Concealed hardware configuration makes system

tamperproof for public space applications. � Recessed frame accommodates all floor finishes

including concrete, terrazzo, tile, VCT and carpet. � Available finish options on page 7. � Mill finish standard.

A01 Floor/Floor (2" (51mm) system shown)

A02 Floor/Wall (2" (51mm) system shown)

% OF MOVEMENT±50%

VAPOR BARRIERoptional

JOINT WIDTH1" (50mm) – 6" (152mm)

FIRE RATEDoptional

A01 Floor/Floor (2" (51mm) system shown)

A02 Floor/Wall (2" (51mm) system shown)

A01 Floor/Floor (2" (51mm) system shown)

A02 Floor/Wall (2" (51mm) system shown)

A01 Floor/Floor (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

320-A01-025 1" 25 1" 25 * * 4 5/8" 117 2 3/4" 70 1/8" 3 1/4" 6320-A01-050 2" 51 1" 25 * * 6 1/8" 156 3 1/4" 83 3/8" 10 1/2" 13320-A01-075 3" 76 1" 25 * * 7 5/8" 194 3 3/4" 95 9/16" 14 3/4" 19320-A01-100 4" 102 1" 25 * * 9 1/8" 232 4 1/4" 108 3/4" 19 1" 25320-A01-150 6" 152 1" 25 * * 12 1/8" 308 5 1/4" 133 1 1/4" 31 1 1/2" 38

S

W

H1

S

W

H1

S

W

H1

H2

312-A01-050

S

W

H1

S

W

H1

S

W

H1

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

300-A01-025 1" 25 1" 25 * * 3 1/4" 83 2 3/4" 70 1/2" 13 1/4" 6300-A01-050 2" 51 1" 25 * * 5 1/4" 133 3 1/4" 83 1" 25 1/2" 13300-A01-075 3" 76 1" 25 * * 7 1/8" 181 3 3/4" 95 1 1/2" 38 3/4" 19300-A01-100 4" 102 1" 25 * * 9 1/8" 232 4 1/4" 108 2" 51 1" 25300-A01-150 6" 152 1" 25 * * 13 1/8" 333 5 1/4" 133 3" 76 1 1/2" 38

Floor to Wall

300-A02-025 1" 25 1" 25 * * 2 1/8" 5 2 3/4" 70 1/8" 3 1/8" 3300-A02-050 2" 51 1" 25 * * 3 5/8" 92 3 1/4" 83 3/8" 10 1/4" 6300-A02-075 3" 76 1" 25 * * 5" 127 3 3/4" 95 9/16" 14 3/8" 10300-A02-100 4" 102 1" 25 * * 6 5/8" 168 4 1/4" 108 3/4" 19 1/2" 13300-A02-150 6" 152 1" 25 * * 9 1/2" 241 5 1/4" 133 1 1/4" 31 3/4" 19

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

304-A01-025 1" 25 1" 25 1/8" 3" 2 5/8" 67 2 3/4" 70 1/2" 13 1/4" 6304-A01-050 2" 51 1" 25 1/8" 3" 3 5/8" 92 3 1/4" 83 1" 25 1/2" 13304-A01-075 3" 76 1" 25 1/8" 3" 4 5/8" 117 3 3/4" 95 1 1/2" 38 3/4" 19304-A01-100 4" 102 1" 25 1/8" 3" 5 5/8" 143 4 1/4" 108 2" 51 1" 25304-A01-150 6" 152 1" 25 1/8" 3" 7 5/8" 194 5 1/4" 133 3" 76 1 1/2" 38

Floor to Wall

304-A02-025 1" 25 1" 25 1/8" 3" 1 3/4" 44 2 3/4" 70 1/8" 3 1/8" 3304-A02-050 2" 51 1" 25 1/8" 3" 2 3/4" 70 3 1/4" 83 3/8" 10 1/4" 6304-A02-075 3" 76 1" 25 1/8" 3" 3 3/4" 95 3 3/4" 95 9/16" 14 3/8" 10304-A02-100 4" 102 1" 25 1/8" 3" 4 3/4" 121 4 1/4" 108 3/4" 19 1/2" 13304-A02-150 6" 152 1" 25 1/8" 3" 6 3/4" 171 5 1/4" 133 1 1/4" 31 3/4" 19

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor312-A01-050 2" 51 1" 25 * * 10 1/8" 257 1 7/8" 48 1" 25 1/2" 13312-A01-075 3" 75 1" 25 * * 131/8" 332 2 7/8" 73 11/2" 38 11/2" 38312-A01-100 4" 102 1" 25 * * 14 1/8" 358 2 7/8" 73 2" 51 1" 25

Floor to Wall312-A02-050 2" 51 1" 25 * * 6" 152 1 7/8" 48 3/8" 10 1/4" 6312-A02-075 3" 75 1" 25 * * 7" 178 1 7/8" 48 9/16" 14 3/8" 10312-A02-100 4" 102 1" 25 * * 9" 229 2 7/8" 73 3/4" 19 1/2" 13

� Exclusive patented “no-bump" configuration makes system ADA compliant (patent #5384996).

� Coverplates rest on high durometer seals to eliminate system rattle.

� Mill finish standard.

18

Page 11: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 21inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Centering Bar

Floor Systems

400 Series systems meet Moderate to Heavy Duty loading scenarios such as warehouses, stadiums, and auditoriums. The center bar and compression spring assembly correctly repositions pan after thermal and seismic movement.

401 Series � Perfect for carpeted conditions. � Cost effective, surface mounted system with wide span capability. � Throat-mounted bracket allows your project's wall base to continue

uninterrupted over the joint cover at floor/wall conditions.

� Highly modifiable systems can meet any project's loads, movement, and finish requirements.

� Standard and custom seal colors available, see page 7.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

401-A01-050 2" 51 1/8" 3 * * 8 1/2" 216 * * 1" 25 1" 25401-A01-100 4" 102 1/8" 3 * * 11 3/4" 298 * * 2" 51 2" 51401-A01-150 6" 152 3/16" 5 * * 14 1/2" 368 * * 3" 76 3" 76401-A01-200 8" 203 3/16" 5 * * 16 1/2" 419 * * 4" 102 4" 102

Floor to Wall

401-A02-050 2" 51 1/8" 3 * * 5 1/4" 132 * * 1" 25 1" 25401-A02-100 4" 102 1/8" 3 * * 8" 202 * * 2" 51 2" 51401-A02-150 6" 152 3/16" 5 * * 10 1/4" 259 * * 3" 76 3" 76401-A02-200 8" 203 3/16" 5 * * 12 1/4" 310 * * 4" 102 4" 102

Wider sizes available

426 - A01 Floor/Floor (14" (350mm) system shown)

426 - A02 Floor/Wall (14" (350mm) system shown)

427 - A01 Floor/Floor for VCT (14" (350mm) system shown)

428 - A01 Floor/Floor for Carpet (14" (350mm) system shown)

2" (52mm)

H2

H2

S H1

W

S

H1

W

421 | 423 | 425 Series – Extra Wide � Ideal for a wide range flooring conditions. � Highly modifiable system – alternate plate

thicknesses allow system to meet many load scenarios.

� The 421 series contains all aluminum components.

� Stainless steel plate available on 423 system. � Stainless steel plate and wings available on

425 system.

426 | 427 | 428 Series – Extra Wide � Full width cover plate creates a seamless transition

over wide structural gaps. � Can be installed with VCT for a narrow sightline

(427 System). � Can be installed with carpet for a narrow sightline

(428 System). � Throat-mounted bracket allows your project's wall base

to continue uninterrupted over the joint cover at floor/wall conditions.

A01 Floor/Floor (2" (51mm) system shown)

A02 Floor/Wall (2" (51mm) system shown)

S

W

H1

421 - A01 Floor/Floor (14" (350mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor421-A01-300 12" 300 1 5/8" 43 * * 28 7/8" 735 8 7/8" 225 6" 152 6" 152421-A01-350 14" 350 1 5/8" 43 * * 33 1/8" 843 10" 254 7" 178 7" 178421-A01-400 16" 400 1 7/8" 48 * * 38 5/8" 983 11 3/4" 298 8" 203 8" 203421-A01-450 18" 450 1 7/8" 48 * * 42 3/4" 1087 12 3/4" 324 9" 229 9" 229

Floor to Wall421-A02-300 12" 300 1 5/8" 43 * * 20 1/2" 520 8 7/8" 225 3" 76 3" 76421-A02-350 14" 350 1 5/8" 43 * * 23 5/8" 599 10" 254 3 1/2" 90 3 1/2" 90421-A02-400 16" 400 1 7/8" 48 * * 27 3/8" 694 11 3/4" 298 4" 102 4" 102421-A02-450 18" 450 1 7/8" 48 * * 30 3/8" 772 12 3/4" 324 4 1/2" 114 4 1/2" 114

Smaller and larger size configurations available

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

426-A01-300 12" 300 1 5/8" 43 * * 28 1/8" 735 8 1/2" 216 6" 152 6" 152426-A01-350 14" 350 1 5/8" 43 * * 33 1/8" 843 10" 254 7" 178 7" 178426-A01-400 16" 400 1 7/8" 48 * * 38 5/8" 983 11 3/4" 298 8" 203 8" 203426-A01-450 18" 450 1 7/8" 48 * * 42 3/4" 1087 12 3/4" 330 9" 229 9" 229427-A01-300 12" 300 1 5/8" 43 1/8" 3 3 3/4" 95 10" 254 6" 152 6" 152427-A01-350 14" 350 1 5/8" 43 1/8" 3 3 3/4" 95 10 1/2" 267 7" 178 7" 178427-A01-400 16" 400 1 7/8" 48 1/8" 3 3 3/4" 95 12 1/8" 308 8" 203 8" 203427-A01-450 18" 450 1 7/8" 48 1/8" 3 3 3/4" 95 13 1/8" 333 9" 229 9" 229428-A01-300 12" 300 1 5/8" 43 3/8" 10 3 3/4" 95 10" 254 6" 152 6" 152428-A01-350 14" 350 1 5/8" 43 3/8" 10 3 3/4" 95 11 1/8" 283 7" 178 7" 178428-A01-400 16" 400 1 7/8" 48 3/8" 10 3 3/4" 95 12 3/4" 325 8" 203 8" 203428-A01-450 18" 450 1 7/8" 48 3/8" 10 3 3/4" 95 13 3/4" 351 9" 229 9" 229

Floor to Wall

426-A02-300 12" 300 1 5/8" 43 * * 20 1/2" 520 8 7/8" 216 3" 76 3" 76426-A02-350 14" 350 1 5/8" 43 * * 23 5/8" 599 10" 254 3 1/2" 90 3 1/2" 90426-A02-400 16" 400 1 7/8" 48 * * 27 3/8" 694 11 3/4" 298 4" 102 4" 102426-A02-450 18" 450 1 7/8" 48 * * 30 3/8" 772 12 3/4" 303 4 1/2" 114 4 1/2" 114427-A02-300 12" 300 1 5/8" 43 1/8" 3 1 7/8" 47 10" 254 3" 76 3" 76427-A02-350 14" 350 1 5/8" 43 1/8" 3 1 7/8" 47 10 1/2" 267 3 1/2" 90 3 1/2" 90427-A02-400 16" 400 1 7/8" 48 1/8" 3 1 7/8" 47 12 1/8" 308 4" 102 4" 102427-A02-450 18" 450 1 7/8" 48 1/8" 3 1 7/8" 47 13 1/8" 333 4 1/2" 114 4 1/2" 114428-A02-300 12" 300 1 5/8" 43 3/8" 10 1 7/8" 47 10" 254 3" 76 3" 76428-A02-350 14" 350 1 5/8" 43 3/8" 10 1 7/8" 47 11 1/8" 283 3 1/2" 90 3 1/2" 90428-A02-400 16" 400 1 7/8" 48 3/8" 10 1 7/8" 47 12 3/4" 325 4" 102 4" 102428-A02-450 18" 450 1 7/8" 48 3/8" 10 1 7/8" 47 13 3/4" 351 4 1/2" 114 4 1/2" 114

Smaller and larger size configurations available

S

W

H1

20

Page 12: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 23inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Centering Bar

Floor Systems

400 Series systems meet Moderate loading scenarios such as medical office buildings, hospital corridors, and school assembly spaces. The center bar and compression spring assembly correctly repositions pan after seismic movement.

441 Series – Recessed Mount � Flooring may be inserted under plate for reduced sightline. � Exposed fastener makes maintenance easier.

430 Recessed Mount – Hidden Fastener � Industry unique, tapered center plate design maintains an

extremely smooth transition, ideal for rolling loads. � Flooring may be inserted under cover plate for

reduced sightline. � Ideal for carpet, vinyl, ceramic tile and other floor finishes.

432 Recessed Mount – Exposed Fastener � Exposed fastener makes maintenance easier for facilities. � Tapered center plate design maintains a seamless transition.

% OF MOVEMENT±50%

VAPOR BARRIERoptional

JOINT WIDTH1" (25mm) – 8" (200mm)

FIRE RATEDoptional

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

430-A01-025 1" 25 1 1/2" 38 * * 4 1/8" 105 3" 76 1/2" 13 1/4" 6430-A01-050 2" 51 1 1/2" 38 * * 5 1/2" 140 3 1/4" 83 1" 25 1/2" 13430-A01-075 3" 76 1 1/2" 38 * * 7 3/4" 197 4" 102 1 1/2" 38 3/4" 19430-A01-100 4" 102 1 1/2" 38 * * 8 3/4" 222 4" 102 2" 51 1" 25430-A01-150 6" 152 1 1/2" 38 * * 13 1/2" 343 5 1/4" 133 3" 76 1 1/2" 38430-A01-200 8" 203 1 1/2" 38 * * 18" 457 7" 178 4" 102 2" 51432-A01-025 1" 25 1 1/2" 38 * * 4 1/8" 105 3" 76 1/2" 13 1/4" 6432-A01-050 2" 51 1 1/2" 38 * * 5 1/2" 140 3 1/4" 83 1" 25 1/2" 13432-A01-075 3" 76 1 1/2" 38 * * 7 3/4" 197 4" 102 1 1/2" 38 3/4" 19432-A01-100 4" 102 1 1/2" 38 * * 8 3/4" 222 4" 102 2" 51 1" 25432-A01-150 6" 152 1 1/2" 38 * * 13 1/2" 343 5 1/4" 133 3" 76 1 1/2" 38432-A01-200 8" 203 1 1/2" 38 * * 18" 457 7" 178 4" 102 2" 51

Floor to Wall

430-A02-025 1" 25 1 1/2" 38 * * 2 1/2" 64 3" 76 1/4" 6 1/4" 6430-A02-050 2" 51 1 1/2" 38 * * 3 3/4" 95 3 1/4" 83 1/2" 13 1/2" 13430-A02-075 3" 76 1 1/2" 38 * * 5 3/8" 137 4" 102 3/4" 19 3/4" 19430-A02-100 4" 102 1 1/2" 38 * * 6 3/8" 162 4" 102 1" 25 1" 25430-A02-150 6" 152 1 1/2" 38 * * 9 3/4" 248 5 1/4" 133 1 1/2" 38 1 1/2" 38430-A02-200 8" 203 1 1/2" 38 * * 13" 330 7" 178 2" 51 2" 51

Hidden Fastener Model 430-A01 Floor/Floor (2" (51mm) system shown)

Exposed Fastener Model 432-A01 Floor/Floor (2" (51mm) system shown)

441-A02 Floor/Wall (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

461-A01-075 3" 76 1 1/2" 38 1/4" 6 9 1/4" 235 4" 102 1 1/2" 38 3/4" 19461-A01-100 4" 102 1 1/2" 38 1/4" 6 10 1/4" 260 4" 102 2" 51 1" 25461-A01-150 6" 152 1 1/2" 38 5/16" 8 15 1/4" 387 5 1/4" 133 3" 76 1 1/2" 38461-A01-200 8" 203 1 1/2" 38 5/16" 8 19 5/8" 498 7" 178 4" 102 2" 51471-A01-075 3" 76 * * 1/4" 6 10 1/2" 267 * * 1 1/2" 38 3/4" 19471-A01-100 4" 102 * * 1/4" 6 11 7/8" 302 * * 2" 51 1" 25471-A01-150 6" 152 * * 5/16" 8 16 7/8" 430 * * 3" 76 1 1/2" 38471-A01-200 8" 203 * * 5/16" 8 21 3/8" 543 * * 4" 102 2" 51

Floor to Wall

471-A02-075 3" 76 * * 1/4" 6 6 3/4" 171 * * 3/4" 19 3/4" 19471-A02-100 4" 102 * * 1/4" 6 7 7/8" 200 * * 1" 25 1" 25471-A02-150 6" 152 * * 5/16" 8 11 1/2" 292 * * 1 1/2" 38 1 1/2" 38471-A02-200 8" 203 * * 5/16" 8 14 3/4" 375 * * 2" 51 2" 51

461-A01 Floor/Floor (4" (100mm) system shown)

471-A01 Floor/Floor (4" (100mm) system shown)

S

W

H2H1

S

W

H2

S

W

H1

461 Series – New to Existing � Designed for retrofits, additions and renovations where blockout

occurs on one side only. � Tapered center plate design maintains smooth transition. � Meets ADA requirements.

471 Series – Surface Mount � Surface mount ideal for retrofits, additions and renovations. � Flooring may be inserted under plate for reduced sightline. � Exposed fastener makes maintenance easier. � Tapered center plate design maintains smooth transition.

430-A02 Floor/Wall (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor441-A01-050 2" 50 1" 25 * * 8 1/2" 216 3 1/4" 83 1" 25 1" 25441-A01-100 4" 100 1" 25 * * 11 3/4" 298 3 1/4" 83 2" 50 2" 50441-A01-150 6" 150 1" 25 * * 14 1/2" 368 3 1/4" 83 3" 75 3" 75

Floor to Wall441-A02-050 2" 50 1" 25 * * 5 1/4" 132 3 1/4" 83 1" 25 1" 25441-A02-100 4" 100 1" 25 * * 8" 202 3 1/4" 83 2" 50 2" 50441-A02-150 6" 150 1" 25 * * 10 1/4" 259 3 1/4" 83 3" 75 3" 75

Other sizes and finishes available

� Mill Finish Standard.

441-A01 Floor/Floor (2" (51mm) system shown)

22

Page 13: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 25inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

S

W

H1

Heavy Duty

Floor Systems

700 Series systems meet Heavy Duty loading scenarios in many environments such as open structures, stadium venues, parking structures, airports, and warehouses.

757 | 767 Series � Flush, constant leveling, low profile design allows for

a smooth transition when traversing joint system. � Optional integral vapor barrier slides directly into

frame for easy installation. � 767 series allows for additional hardware anchorage

points in environments with high vibration or vehicular loading.

� Utilizes elastomeric concrete system nosing to reduce vibrations imposed on the system – resulting in extended -life of the components.

� Mill finish standard.

741 Series � Cost-effective option for a high load bearing system. � Engineered for pneumatic and solid tires. � Stainless steel plate available. � System designed to be installed over floor finishes.

721 | 723 | 725 Series � Highly modifiable system capable of meeting many

loading scenarios. � Heavy duty bearing system. � Engineered for pneumatic and solid tires. � Stainless steel plate available on 723 system. � Stainless steel plate and wings available on 725 system.

721-A01 Floor/Floor (4" (100mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor741-A01-050 2" 50 1" 25 * * 8 1/2" 216 3 1/4" 83 1" 25 1" 25

741-A01-100 4" 100 1" 25 * * 11 3/4" 298 3 1/4" 83 2" 50 2" 50

741-A01-150 6" 150 1" 25 * * 14 1/2" 368 3 1/4" 83 3" 75 3" 75

Other sizes and finishes available

S

W

H1

757-A01 Floor/Floor (8" (200mm) system shown)

767-A01 Floor/Floor (8" (200mm) system shown)

741-A01 Floor/Floor (4" (100mm) system shown)

Optional vapor barrier shown

% OF MOVEMENT±50% - 100%

VAPOR BARRIERoptional

JOINT WIDTH2"-12"

FIRE RATEDoptional

Application System

W H1 S B Movement +/-

Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical

US mm US mm US mm US mm US mm US mm

Floor to Floor

721-A01-050 2” 51 1 5/8” 40 8 1/2” 216 3 3/4” 95 1” 25 1” 25

721-A01-100 4” 102 1 5/8” 40 12 1/2” 318 4 3/4” 121 2” 51 2” 51

721-A01-150 6” 152 1 5/8” 40 16 1/2” 406 5 3/4” 146 3” 76 3” 76

721-A01-200 8” 203 1 5/8” 40 20 1/2” 502 6 3/4” 171 4” 102 4” 102

721-A01-300 12” 305 1 5/8” 40 28 1/2” 705 8 3/4” 222 6” 152 6” 152

Floor to Wall

721-A02-050 2” 51 1 5/8” 40 5 1/4” 133 3 3/4” 95 1/2” 13 1/2” 13

721-A02-100 4” 102 1 5/8” 40 8 1/4” 210 4 3/4” 121 1” 25 1” 25

721-A02-150 6” 152 1 5/8” 40 11 1/4” 286 5 3/4” 146 1 1/2” 38 1 1/2” 38

721-A02-200 8” 203 1 5/8” 40 14 1/4” 362 6 3/4” 171 2” 51 2” 51

721-A02-300 12” 305 1 5/8” 40 20 1/4” 515 8 3/4” 222 3” 76 3” 76

Larger sizes available

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor757-A01-100 4" 100 2" 51 * * 13 1/2" 222 6 5/8" 102 2" 51 3/4" 152757-A01-150 6" 150 2" 51 * * 15 1/2" 394 6 5/8" 206 3" 76 1 1/2" 178757-A01-200 8" 200 2" 51 * * 17 1/2" 445 6 5/8" 206 4" 102 2" 203

W

S

H1

S

W

H1

Optional vapor barrier available

24

Page 14: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 27inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Heavy Duty Seismic

Floor Systems

787-A02 Floor/Wall (4" (100mm) system shown)

NEW! 787 Series

Application SystemW H S B Movement +/-

Joint Width Frame Height Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm

Floor to Floor

787-A01-100 4" 100 1" 25 13 1/2" 342 6 " 152 2" 51 1" 25787-A01-150 6" 150 1" 25 16 1/2" 419 6 1/2" 165 3" 76 1 1/2" 38787-A01-200 8" 200 1" 25 18 1/2" 470 6 1/2" 165 4" 102 2" 51

787-A01-150 10” 250 1” 25 24 1/2” 622 8 1/2” 216 5” 127 2 1/2” 64

787-A01-150 12” 300 1” 25 26 1/2” 673 8 1/2” 216 6” 152 3” 76

Floor to Wall

787-A02-100 4” 100 1” 25 8 3/4” 222 6” 152 1” 25 1” 25787-A02-150 6” 150 1” 25 11 1/4” 286 6 1/2” 165 1 1/2” 76 1 1/2” 38

787-A02-200 8” 200 1” 25 13 1/4” 337 6 1/2” 165 2” 102 2” 51

787-A02-250 10” 250 1” 25 17 1/4” 438 8 1/2” 216 2 1/2” 127 2 1/2” 64

787-A02-300 12” 300 1” 25 19 1/4” 489 8 1/2” 216 3” 152 3” 76

787-A01 Floor/Floor (4" (100mm) system shown)

787 Series � Seismic capable system designed to meet the needs of an open

structure and vehicular loading scenarios. � Heavy duty design uses a thick, high strength centering bar and

spring assembly to resist vibrations, extending joint lifecycle. � Industry unique, low profile design reduces the lateral impact

(shear forces) encountered with repeated vehicular traffic. � Tapered plate and frames provide a seamless design that

constantly levels itself and maintains a flush condition. � Serrated cover plate for added slip resistance. � One [32mm] frame depth ensures no interference in rebar/

cabling structures with concrete decks. � Integral high durometer seal acts as a noise dampener and

deters water from slipping beneath plate. � Mill finish standard.

% OF MOVEMENT25%-50%

VAPOR BARRIERoptional

JOINT WIDTH4"-12"

FIRE RATEDoptional

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor801-A01-025 1" 25 1/8" 3 * * 4 1/8" 105 * * 1/2" 13 * *801-A01-050 2" 51 1/8" 3 * * 5 5/8" 143 * * 1" 25 * *

Floor to Wall801-A02-025 1" 25 1/8" 3 * * 1 1/2" 38 * * 1/2" 13 * *801-A02-050 2" 51 1/8" 3 * * 3" 76 * * 1" 25 * *

Additional sizes and finishes available

Standard Cover Plate

Floor Systems

A01 Floor/Floor (1" (25mm) system shown)

804 Series � Spring clip design for easy on-site installation. � A07 Condition offers finish options on page 7. � Designed to be installed over floor finishes.

801 Series � Beveled edges provide pedestrian safety. � Pre-drilled counter-sunk holes for easy

installation. � Available in stainless steel and other

custom finishes.

A01 Floor/Floor (1" (25mm) system shown)

A02 Floor/Wall (1" (25mm) system shown)

S

W

H1

S

W

H1

A02 Floor/Wall (2" (51mm) system shown)

The 800 Series is our most cost effective product line. Suitable for many joint sizes in a variety of applications.

Optional vapor barrier available

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor804-A01-025 1" 25 1/8" 4 * * 3" 76 * * 1/4" 6 1/8" 3804-A01-038 1 1/2" 38 1/8" 4 * * 3" 76 * * 3/8" 10 1/8" 3804-A01-050 2" 51 1/8" 4 * * 4" 114 * * 1/2" 13 1/8" 3

Floor to Wall804-A02-025 1" 25 1/8" 4 * * 2" 50 * * 1/4" 6 1/8" 3804-A02-038 1 1/2" 38 1/8" 4 * * 2" 50 * * 3/8" 10 1/8" 3804-A02-050 2" 51 1/8" 4 * * 3 1/4" 83 * * 1/2" 13 1/8" 3

� Mill finish standard.

26

Page 15: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 29inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

A01 Floor/Floor (2" (51mm) system shown)

A02 Floor/Floor (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

802-A01-050/3 2" 51 1/8" 3 1/8" 4 2" 51 * * 1/2" 13 * *802-A01-050/6 2" 51 1/8" 3 1/4" 6 2" 51 * * 1/2" 13 * *

802-A01-050/10 2" 51 1/8" 3 3/8" 10 2" 51 * * 1/2" 13 * *J807-A01-050 2" 50 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25J807-A01-075 3" 75 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25J807-A01-100 4" 100 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25J807-A01-150 6" 150 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25

Floor to Wall

J807-A02-050 2" 50 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25J807-A02-075 3" 75 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25J807-A02-100 4" 100 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25J807-A02-150 6" 150 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25

A01 Floor/Floor (2" (51mm) system shown)

A02 Floor/Wall (2" (51mm) system shown)

A01 Floor/Floor (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

808-A01-025 1" 25 1/4" 6 * * 6" 152 * * 1/2" 13 1/2" 13808-A01-050 2" 51 1/4" 6 * * 6" 152 * * 1" 25 1 25808-A01-075 3" 76 1/4" 6 * * 10" 254 * * 1 1/2" 38 1 1/2" 38808-A01-100 4" 102 1/4" 6 * * 10" 254 * * 2" 51 2" 51

S

W

H1

S

W

H1

Standard Cover Plate

Floor Systems 808 Series � Beveled edges and serrated plates provide traction

for pedestrian safety. � Pre-drilled counter-sunk holes for easy installation. � Designed to be installed over finished flooring.

806 Series � Designed for uneven slab conditions and

vertical shear conditions. � Moderate loading capabilites. � Pre-drilled counter-sunk holes for easy

installation. � Unlimited lateral shear movement. � Designed to be installed over finished flooring.

802/807 Series � Design accommodates various flooring

thicknesses and finishes from carpet to VCT. � Overlap design reduces sightline to only 2".

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

806-A01-050 2" 51 1/4" 6 * * 7" 178 * * 1" 25 * *806-A01-100 4" 102 1/4" 6 * * 10 1/2" 267 * * 2" 51 * *806-A01-150 6" 152 1/4" 6 * * 13" 330 * * 3" 76 * *806-A01-200 8" 203 5/16" 8 * * 17" 432 * * 4" 102 * *806-A01-300 12" 305 5/16" 8 * * 23" 584 * * 6" 152 * *

Floor to Wall

806-A02-050 2" 51 1/4" 6 * * 4" 102 * * 1" 25 * *806-A02-100 4" 102 1/4" 6 * * 7 1/2" 191 * * 2" 51 * *806-A02-150 6" 152 1/4" 6 * * 10" 254 * * 3" 76 * *806-A02-200 8" 203 5/16" 8 * * 13" 330 * * 4" 102 * *806-A02-300 12" 305 5/16" 8 * * 19" 483 * * 6" 152 * *

� Mill finish standard.

S

H1

W

158"

[41mm]

H2

28

Page 16: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 31inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

501-A01-100-POPPED

Central pan rides up the frame under seismic movement then returns to position to maintain egress routes.

A01 Floor/Floor (4" (100mm) system shown)

A01 Floor/Floor(4" (100mm) system shown)

501 Series – “Pop-up” Pan System � The combined use of centerbars and compression

spring components correctly repositions the pan after seismic movement.

� The 501 system can reduce expansion joints of up to 8" in width down to just two 1/2" (13mm) reveals.

� Ideal for carpeted areas where slim sightlines on larger joints are required for aesthetic reasons.

� Floor-to-Floor applications only.

NEW! 502 Series – “Hinged” Pan System Ideal for floor finishes with increased depths such as marble, granite, limestone and paver systems.

� System provides for unlimited lateral movement.

� Pan profile provides a vertical surface to abut tile against, eliminating the need to bevel flooring edges.

� Reveals align for Floor-to-Floor and Floor-to-Wall applications.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

501-A01-050 2" 51 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 2" 6501-A01-075 3" 76 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 3" 13501-A01-100 4" 102 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 4" 19501-A01-150 6" 152 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 6" 25501-A01-200 8" 203 2" 51 1 1/2" 38 1" 25 5" 127 7 1/2" 191 8" 38

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor

502-A01-050 2" 51 2" 51 5 1/2" 139 1" 25 9 3/8" 238 1" 25 1" 25502-A01-100 4" 102 2" 51 5 1/2" 139 1" 25 7 3/8" 187 2" 51 2" 51502-A01-150 6" 152 2" 51 5 1/2" 139 1" 25 8 3/8" 222 3" 76 3" 76502-A01-200 8" 203 2" 51 5 1/2" 139 1" 25 9 3/8" 238 4" 102 4" 102

Floor to Wall

502-A02-050 2" 51 2" 51 5 1/2" 139 1" 25 9 3/8" 238 1" 25 1" 25502-A02-100 4" 102 2" 51 5 1/2" 139 1" 25 7 3/8" 187 2" 51 2" 51502-A02-150 6" 152 2" 51 5 1/2" 139 1" 25 8 3/8" 222 3" 76 3" 76502-A02-200 8" 203 2" 51 5 1/2" 139 1" 25 9 3/8" 238 4" 102 4" 102

Narrow Sightline and Pan Systems

Floor Systems

A02 Floor/Wall (2" (51mm) system shown)

A01 Floor/Floor (2" (51mm) system shown)

316 Series Single Sightline � Reduces 2-4" gaps to only a 3/4" (19mm)

single sightline. � Multifunction design provides for alignment of

system sightlines at continuous Floor-to-Floor and Floor-to-Wall conditions.

� Specifically designed for continuous flooring types such as carpeting or vinyl sheet.

� Rated for high pedestrian load.

% OF MOVEMENT±50% - 100%

VAPOR BARRIERoptional

JOINT WIDTH2" (25mm) – 12" (300mm)

FIRE RATEDoptional

Virtually eliminate wide sightlines.Configurations allow for use on new construction or renovations. These multifunction designs provide alignment for floor and corner conditions.

Application SystemW H1 S B Movement +/-

Joint Width Frame Height 1 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm

Floor to Floor316-A01-050 2" 51 2" 51 1" 25 4 1/2" 114 1" 25 1" 25316-A01-075 3" 76 2" 51 1" 25 4 1/2" 114 1 1/2" 38 1 1/2" 38316-A01-100 4" 102 2" 51 1" 25 4 1/2 114 1 1/2" 38 1 1/2" 38

Floor to Wall316-A02-050 2" 51 2" 51 1" 25 4 1/2" 114 1" 25 1" 25316-A02-075 3" 76 2" 51 1" 25 4 1/2" 114 1 1/2" 38 1 1/2" 38316-A02-100 4" 102 2" 51 1" 25 4 1/2 114 1 1/2" 38 1 1/2" 38

S

H1

W

S

H2

B

B1min. blockout

H12"

[50mm]W

Hinged pan rides up the canted frame under seismic movement then returns to position to maintain egress routes.

A02 Floor/Wall(4" (100mm) system shown)

30

Page 17: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 33inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

JointMaster™ offers a comprehensive line of Wall and

Ceiling Expansion Joint Systems with recessed and drywall

options for both thermal and seismic conditions.

Wall and Ceiling Systems

San Francisco, California

The ProjectThe $220 million Exploratorium is located in the heart of San Francisco’s waterfront. Hands-on exhibits explore biology, physics, listening, cognition, visual perception, social behavior, and the environment.

The ChallengeAfter a groundbreaking in October 2010, the first phase of this project included refurbishing and seismically upgrading the historic Pier 15 – spanning the length of almost three football fields over the water. Engineers drove piles underneath the bay to replace, repair and/or seismically upgrade, hundreds of dilapidated pilings and the substructure, some which date to the early 20th century.

The built space of 330,000 square feet includes quintessential Exploratorium exhibits in four galleries; space for professional teacher training, after-school programs, educational camps and lifelong learning; a theater; the Exploratorium store; and a café.

The SolutionJointMaster provided the entire expansion joint and barrier package for the Exploratorium project. Almost 1,500 linear feet of interior and exterior seismic expansion joints are used throughout the building. Joint widths varied from 8" to as wide as 27". Of that, nearly 95 percent of the joint systems were custom designed and built, including several joints incorporating 3/8" thick aluminum diamond plate.

Because the Exploratorium is built over the water, designers specified Kynar® coatings on many of the joint systems to fight salt-water effects. In addition, waterproof fire barrier was incorporated where specified.

And in the spirit and style of the Exploratorium, there is a display dedicated to the expansion joints used, helping visitors and students understand a building’s constant battle with Mother Nature, and how expansion joints help a building withstand thermal and seismic movement.

Architect: Esherick Homey Dodge & Davis San Francisco, California

General Contractor: Nibbi Brothers San Francisco, California

Expansion Joint Contractor: Expansion Specialties, Inc. Henderson, Nevada

Project Profile The Exploratorium® at Pier 15

32

Page 18: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 35inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Drywall Finishes

Wall and Ceiling Systems

113 | 113A Series – Surface Mount � Frame allows for finish with joint compound or wall covering. � Dual durometer seal provides secure fit and optimal flexibility. � Sightline reduced to width of flexible seals.

112 Series – Recessed Mount for 5/8" (16mm) Drywall � Snap-in frame accepts 5/8" (16mm) drywall.

No finish required, saving on site installation costs. � Clear anodized aluminum for a decorative finish. � Available finish options see page 7.

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

112-A07-025 1" 25 5/8" 16 * * 2" 51 * * 1/4" 6 1/4" 6112-A07-038 1 1/2" 38 5/8" 16 * * 2 7/16" 62 * * 3/8" 10 3/8" 10112-A07-050 2" 51 5/8" 16 * * 2 7/8" 73 * * 1/2" 13 1/2" 13112-A07-075 3" 76 5/8" 16 * * 4" 102 * * 3/4" 19 3/4" 19

Wall to CornerWall to Ceiling

112-A09-025 1" 25 5/8" 16 * * 1 1/2" 38 * * 1/4" 6 1/4" 6112-A09-038 1 1/2" 38 5/8" 16 * * 1 15/16" 49 * * 3/8" 10 3/8" 10112-A09-050 2" 51 5/8" 16 * * 2 3/8" 60 * * 1/2" 13 1/2" 13112-A09-075 3" 76 5/8" 16 * * 3 3/8" 86 * * 3/4" 19 3/4" 19

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

113-A07-025 1" 25 * * * * 1" 25 * * 1/4" 6 1/4" 6113-A07-038 1 1/2" 38 * * * * 1 1/2" 36 * * 3/8" 10 3/8" 10113-A07-050 2" 51 * * * * 2" 47 * * 1/2" 13 1/2" 13113-A07-075 3" 76 * * * * 3" 76 * * 3/4" 19 3/4" 19

Wall to CornerWall to Ceiling

113-A09-025 1" 25 * * * * 1" 25 * * 1/4" 6 1/4" 6113-A09-038 1 1/2" 38 * * * * 1 1/2" 36 * * 3/8" 10 3/8" 10113-A09-050 2" 51 * * * * 2" 47 * * 1/2" 13 1/2" 13113-A09-075 3" 76 * * * * 3" 73 * * 3/4" 19 3/4" 19

SW

H1

A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown)

SW

H1

SWSW

V24 Ceiling/Ceiling (2" (51mm) system shown)

V23 Ceiling/Wall (2" (51mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown)

101 Recessed Mount � Recessed mount frame for minimal sightline. � Dual durometer seal provides secure fit and optimal

flexibility. � Adaptable to any 5/8" (16mm) wall and ceiling finish,

including drywall, plaster and tile. � Snap-fit design allows for easy on-site assembly.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

821-V24-025 1" 25 * * * * 1" 25 * * 1/2" 13 1/2" 13821-V24-050 2" 51 * * * * 2" 51 * * 1" 25 1/2" 13821-V23-025 1" 25 * * * * 1" 25 * * 1/2" 13 1/2" 13821-V23-050 2" 51 * * * * 2" 51 * * 1" 25 1/2" 13

Standard color bright white

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

101-A07-025 1" 25 3/4" 19 5/8" 16 1" 25 * * 1/4" 6 1/4" 6101-A07-038 1 1/2" 38 3/4" 19 5/8" 16 1 7/16" 36 * * 3/8" 10 3/8" 10101-A07-050 2" 51 3/4" 19 5/8" 16 1 7/8" 47 * * 1/2" 13 1/2" 13101-A07-075 3" 76 3/4" 19 5/8" 16 2 7/8" 73 * * 3/4" 19 3/4" 19

Wall to CornerWall to Ceiling

101-A09-025 1" 25 3/4" 19 5/8" 16 1" 25 * * 1/4" 6 1/4" 6101-A09-038 1 1/2" 38 3/4" 19 5/8" 16 1 7/16" 36 * * 3/8" 10 3/8" 10101-A09-050 2" 51 3/4" 19 5/8" 16 1 7/8" 47 * * 1/2" 13 1/2" 13101-A09-075 3" 76 3/4" 19 5/8" 16 2 7/8" 73 * * 3/4" 19 3/4" 19

SW

H2

821 Acoustical Ceiling � Pop-rivet design allows for easy on-site assembly. � Co-extruded pleated vinyl allows fluid movement. � Bright white seal only.

S

S

% OF MOVEMENT±25%

VAPOR BARRIERoptional

JOINT WIDTH1" (25mm) – 3" (76mm)

FIRE RATEDoptional

Cost effective systems with simple installations assist in controlling project budgets.

� Standard and custom seal colors available, see page 7.W

H1

S

34

Page 19: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 37inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Drywall, Acousitical, Flush Mount

Wall and Ceiling Systems 611 Series – Flush Mount � Sightline reduced to width of flexible seal. � Seals available in standard and custom colors see page 7.

612 Series – Flush Mount � Industry-unique Santoprene™ seal design

allows for fluid seismic movement during joint expansion and contraction.

� Field heat weldable Santoprene seals for weather tight seams and crisp transitions.

� Seal walls are among the thickest in the industry allowing our product to be used in soffits and corridor ceilings with no sagging.

114 Series – Drywall � Frame allows for finish with joint compound or

wall covering to minimize sightline.

SW

A07 Wall/Wall Ceiling/Ceiling (3" (75mm) system shown)

S

W

Pleated Santoprene® seal design allows for fluid, thermal and seismic movement during joint expansion, contraction, lateral and out-of-plane movement.

� Standard and custom seal colors available, see page 7.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

114-A07-050 2" 51 * * * * 2 1/8" 54 * * 1" 25 1" 25114-A07-075 3" 76 * * * * 3 1/16" 78 * * 1 1/2" 38 1 1/2" 38114-A07-100 4" 102 * * * * 4 1/8" 105 * * 2" 51 2" 51114-A07-150 6" 152 * * * * 6 1/8" 156 * * 3" 76 3" 76

Wall to CornerWall to Ceiling

114-A09-050 2" 51 * * * * 2" 51 * * 1" 25 1" 25114-A09-075 3" 76 * * * * 3" 76 * * 1 1/2" 38 1 1/2" 38114-A09-100 4" 102 * * * * 4" 102 * * 2" 51 2" 51114-A09-150 6" 152 * * * * 6" 152 * * 3" 76 3" 76

A24 Ceiling/Ceiling (2" (51mm) system shown)

A09 Wall/Corner Wall/Ceiling (3" (75mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

115-A24-050 2" 51 * * * * 2" 51 * * 1" 25 1" 25115-A24-075 3" 76 * * * * 3" 76 * * 1 1/2" 38 1 1/2" 38115-A24-100 4" 102 * * * * 4" 102 * * 2" 51 2" 51

Wall to CornerWall to Ceiling

115-A18-050 2" 51 * * * * 2" 51 * * 1" 25 1" 25115-A18-075 3" 76 * * * * 3" 76 * * 1 1/2" 38 1 1/2" 38115-A18-100 4" 102 * * * * 4" 102 * * 2" 51 2" 51

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (12" (300mm) system shown)

A09 Wall/Corner Wall/Ceiling (10" (250mm) system shown)

W W

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

611-A07-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25611-A07-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38611-A07-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51611-A07-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76

Wall to CornerWall to Ceiling

611-A09-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25611-A09-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38611-A09-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51611-A09-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76

SW

H1

SW

H1

A18 Wall/Ceiling (2" (51mm) system shown)

A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown)

% OF MOVEMENT±50% - 100%

VAPOR BARRIERoptional (114)

JOINT WIDTH2" (50mm) – 6" (150mm)

FIRE RATEDoptional (144 & 611)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to Wall

612-A07-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102612-A07-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127612-A07-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152612-A07-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229612-A07-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305

Wall to Corner

612-A09-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102612-A09-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127612-A09-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152612-A09-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229612-A09-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305

Larger sizes available

115 Series – Acoustical Ceiling � Frame pop rivets to T-Bar profile in suspended ceiling

system. � Seal design allows for seismic movement.

36

Page 20: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 39inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Drywall, Flush Mount

Wall and Ceiling Systems

� Center bar and compression spring assembly correctly repositions pan after seismic movement.

� Seal barbs provide secure engagement in frame, making installation easier.

� Face of seal resists sagging and remains flat in ceiling conditions. � Field heat-weldable Santoprene™ seals for weather

tight transitions. � Standard and custom seal colors available, see page 7.

Accommodates large joint widths with narrow sightlines for minimal aesthetic interruption.

% OF MOVEMENT±25%

VAPOR BARRIERoptional

JOINT WIDTH8" (200mm)-24" (600m)

FIRE RATEDoptional

221 Series – Aluminum Plate � Intended for use on smaller joint sizes

where durability is required. � Easy installation and maintenance. � Anodized finish standard.

233 Series – Drywall � Flat seal allows for 25% thermal movement prior to engaging

center bar spring which allows for the full 50% movement. � 3/8” Drywall within center pan cover to be painted or wall

covered to reduce sightline. � Intended for use on joints with both thermal and seismic

capable needs.

A09 Wall/Corner Wall/Ceiling (8" (200mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (8" (200mm) system shown)

A09 Wall/Corner Wall/Ceiling (8" (200mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (8" (200mm) system shown)

H1

SSH2

W

H1

S

W

H2

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to Wall

223-A07-150 6" 152 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51223-A07-200 8" 200 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51223-A07-250 10" 250 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51223-A07-300 12" 300 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51223-A07-350 14" 350 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51223-A07-400 16" 400 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51223-A07-450 18" 450 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51

Wall to Corner

223-A09-150 6" 152 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25223-A09-200 8" 200 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25223-A09-250 10" 250 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25223-A09-300 12" 300 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25223-A09-350 14" 350 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25223-A09-400 16" 400 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25223-A09-450 18" 450 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25

Larger sizes available

223 Series � Flat seal allows for 25% thermal movement prior to engaging

center bar spring which allows for the full 50% movement. � 3/8” Drywall within center pan cover to be painted or wall

covered to reduce sightline. � Intended for use on joints with a high degree of

thermal movement.

A09 Wall/Corner Wall/Ceiling (8" (200mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (8" (200mm) system shown)

H2

W

S S

SH2

W

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to Wall

233-A07-150 6" 152 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51233-A07-200 8" 200 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51233-A07-250 10" 250 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51233-A07-300 12" 300 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51233-A07-350 14" 350 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51233-A07-400 16" 400 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51233-A07-450 18" 450 5/8" 16 3/8" 10 6" 150 * * 2" 51 2" 51

Wall to Corner

233-A09-150 6" 152 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25233-A09-200 8" 200 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25233-A09-250 10" 250 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25233-A09-300 12" 300 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25233-A09-350 14" 350 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25233-A09-400 16" 400 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25233-A09-450 18" 450 5/8" 16 3/8" 10 3" 75 * * 1" 25 1" 25

Larger sizes available. Custom size joints of 30"+ available.

Application SystemW H1 S B Movement +/-

Joint Width Frame Height 1 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm

Floor to Floor

221-A01-050 2" 51 5/8" 16 4 7/8" 124 1 1/2" 13 1/2" 13 1/2" 13221-A01-100 4" 102 5/8" 16 9 3/8" 238 2 3/4" 70 1" 25 1" 25221-A01-150 6" 152 5/8" 16 11 3/8" 289 2 3/4" 70 1" 25 1" 25221-A01-200 8" 200 5/8" 16 18" 457 4 1/2" 114 4 100 4 100221-A01-250 10" 250 5/8" 16 21" 533 4 1/2" 114 5 125 5 125221-A01-300 12" 300 5/8" 16 24" 609 4 1/2" 114 6 150 6 150221-A01-350 14" 350 5/8" 16 27" 686 4 1/2" 114 7 175 7 175221-A01-400 16" 400 5/8" 16 30" 762 4 1/2" 114 8 200 8 200221-A01-450 18" 450 5/8" 16 33" 838 4 1/2" 114 9 225 9 225

Floor to Wall

221-A02-050 2" 51 5/8" 16 3 1/2" 89 1 1/2" 13 1/4" 6 1/4" 6221-A02-100 4" 102 5/8" 16 6 5/8" 168 2 3/4" 70 1/2" 13 1/2" 13221-A02-150 6" 152 5/8" 16 8 5/8" 219 2 3/4" 70 1/2" 13 1/2" 13221-A02-200 8" 200 5/8" 16 13" 330 4 1/2" 114 4 100 4 100221-A02-250 10" 250 5/8" 16 15 1/2" 394 4 1/2" 114 5 125 5 125221-A02-300 12" 300 5/8" 16 18" 457 4 1/2" 114 6 150 6 150221-A02-350 14" 350 5/8" 16 20 1/2" 521 4 1/2" 114 7 175 7 175221-A02-400 16" 400 5/8" 16 23" 584 4 1/2" 114 8 200 8 200221-A02-450 18" 450 5/8" 16 25 1/2" 648 4 1/2" 114 9 225 9 225

Larger sizes available – Custom joints up to 30" available.

38

Page 21: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 41inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Drywall, Flush Mount

Wall and Ceiling Systems

A09 Wall/Corner Wall/Ceiling (8" (200mm) system shown)

A09 Wall/Corner Wall/Ceiling (8" (200mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (8" (200mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (8" (200mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to Wall

243-A07-150 6" 152 5/8" 16 3/8" 10 6" 150 * * 1 1/2" 38 1 1/2" 38243-A07-200 8" 200 5/8" 16 3/8" 10 8" 200 * * 4" 102 4" 102243-A07-250 10" 250 5/8" 16 3/8" 10 10" 250 * * 5" 127 5" 127243-A07-300 12" 300 5/8" 16 3/8" 10 12" 300 * * 6" 152 6" 152243-A07-350 14" 350 5/8" 16 3/8" 10 12" 300 * * 6" 152 6" 152243-A07-400 16" 400 5/8" 16 3/8" 10 12" 300 * * 6" 152 6" 152243-A07-450 18" 450 5/8" 16 3/8" 10 12" 300 * * 6" 152 6" 152

Wall to Corner

243-A09-150 6" 152 5/8" 16 3/8" 10 3" 75 * * 3/4" 19 3/4" 19243-A09-200 8" 200 5/8" 16 3/8" 10 4" 100 * * 2" 51 2" 51243-A09-250 10" 250 5/8" 16 3/8" 10 5" 125 * * 21/2" 64 21/2" 64243-A09-300 12" 300 5/8" 16 3/8" 10 6" 150 * * 3" 76 3" 76243-A09-350 14" 350 5/8" 16 3/8" 10 6" 150 * * 3" 76 3" 76243-A09-400 16" 400 5/8" 16 3/8" 10 6" 150 * * 3" 76 3" 76243-A09-450 18" 450 5/8" 16 3/8" 10 6" 150 * * 3" 76 3" 76

Larger sizes available. Custom size joints of 30" available.

243 Series – Drywall � Pleated seal allows for 50% movement within system

prior to engaging center bar spring. � Ideal for environments where a high degree both thermal

and seismic movement joint fluctuation is expected.

NEW! 253 Series – Aluminum Plate � System allows for thermal and seismic movement without

the use of the Santoprene seals. � Metal center pan can be fabricated to meet any joint width requirement. � System can be utilized in exterior environments as well as interior. � Clear anodized finish standard.

S

WH1

5/8” (16mm)

H1

s

w

Application SystemW H1 S B Thermal Movement +/- Seismic Movement +/-

Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm US mm

Wall to Wall

253-A07-150 6" 152 5/8" 16 15" 381 * * 2" 51 2" 51 3" 76 3" 76253-A07-200 8" 200 5/8" 16 19" 483 * * 2" 51 2" 51 4" 102 4" 102253-A07-250 10" 250 5/8" 16 22 1/2" 572 * * 2" 51 2" 51 5" 127 5" 127253-A07-300 12" 300 5/8" 16 25 3/4" 654 * * 2" 51 2" 51 6" 152 6" 152

Wall to Corner

253-A09-150 6" 152 5/8" 16 11 3/8" 289 * * 7/8" 25 7/8" 23 1 1/2" 38 1 1/2" 38253-A09-200 8" 200 5/8" 16 13 3/8" 340 * * 1" 25 1" 25 2" 51 2" 51253-A09-250 10" 250 5/8" 16 16 1/8" 410 * * 1" 25 1" 25 2 1/2" 64 2 1/2" 64253-A09-300 12" 300 5/8" 16 18 1/8" 460 * * 1" 25 1" 25 3" 76 3" 76

`

Owensboro, Kentucky

The ProjectOwensboro Medical Health Center, Owensboro Campus – Owensboro, Kentucky.

HGA Architects designed the 780,000 square-foot, 9-story tall Medical Center. The 145 acre medical complex boasts a 447 bed inpatient Tower, Diagnostics and Treatment Building, Emergency Department, Women’s Center, and Heart Center. The ChallengeSpecial treatment of the built environment was the driving factor in many design decisions- the goal was to create a warm, healing environment that was welcoming to the diverse patient population.

HGA consulted with JointMaster’s Engineering team to explore expansion joint cover options. The main focus was to reduce joint systems sightlines to a bare minimum so as not to detract from the richly finished aesthetic. This was no small task considering expansion joint structural gaps started at 4” on the ground floor and incrementally increased in sizes up to 36” on the floor decks, interior walls, exterior façade and roofs. In addition to this, there was a requirement to design a 30” wide joint cover that allowed for the exterior to be skinned in a continuously glazed curtain wall system as well as a stone veneer. The hurdles included heavy material weights, matching reveal patterns and incorporating an insulation system to help reduce HVAC lifecycle costs.

The SolutionJointMaster™ met the challenge by developing seismic-capable joint covers that took on the adjacent finishes to mask their sheer size. Interior floor systems allow for incorporation of carpeting and ceramic tile. The interior walls contain recessed coverplates allowing for the mounting of drywall, so paint and wallcovering finishes continue uninterrupted. Our wide, pleated seal products were utilized heavily in the ceilings and soffits in the corridors as well.

The exterior system design was a true marvel with the development and release of the JointMaster STEALTH Series exterior system. This allowed the Architects to seamlessly incorporate the façade materials into the expansion cover. Spandrel glazing was mounted within the covers on the high profile, curvilinear veneer. Behind the joint centerpan resides an Insulated Vapor Barrier system maintaining an R-Value of 15+ while matching the vertical shear movement capabilities of the STEALTH cover.

JointMaster provided on-site support during construction to assist crews in correct installation and to maximize their efficiency. Systems utilized on this project include our 223 Floor joints, 243 Wall covers, 601 STEALTH, 612 and 616 Series Exteriors, as well as Foam Seals and the 975 Fire Barrier systems.

Project Profile Owensboro Health

H1

S S

W

H2

S

H1

S

W

H2

40

Page 22: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 43inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Glide Plate, Centering Bar

Wall and Ceiling Systems 318 Series – Glide Plate � Specifically designed for vinyl wall covering, although can be

utilized in conjunction with other finishes as well. � Single narrow sightline preferred by interior designers.

300 Series – Glide Plate � 5/8" recessed frame designed for inset into drywall installations.

(Can be surface mounted as well). � Snap-fit cover design for easy on-site assembly, no exposed

fasteners makes system ideal for public/high abuse conditions.

� Durably engineered systems hold up in interior and exterior wall applications.

� Provide crisp lines and shadows for a clean finished look.

A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

300-A07-025 1" 25 5/8" 16 * * 5" 127 2" 51 1/2" 13 1/4" 6300-A07-050 2" 51 5/8" 16 * * 6" 152 2" 51 1" 25 1/2" 13300-A07-075 3" 76 5/8" 16 * * 9" 229 3" 76 1 1/2" 38 3/4" 19300-A07-100 4" 102 5/8" 16 * * 10" 254 3" 76 2" 51 1" 25300-A07-150 6" 152 5/8" 16 * * 14" 356 4" 102 3" 76 1 1/2" 38

Wall to CornerWall to Ceiling

300-A09-025 1" 25 5/8" 16 * * 2 3/8" 60 2" 51 1/4" 6 1/4" 6300-A09-050 2" 51 5/8" 16 * * 3 3/8" 86 2" 51 1/2" 13 1/2" 13300-A09-075 3" 76 5/8" 16 * * 5 3/8" 137 3" 76 3/4" 19 3/4" 19300-A09-100 4" 102 5/8" 16 * * 6 3/8" 162 4" 102 1" 25 1" 25300-A09-150 6" 152 5/8" 16 * * 9 3/8" 238 5" 127 1 1/2" 38 1 1/2" 38

SW

H1

S

W

H1

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

481 Series – Centering Bar 491 Series – Surface Mount Centering Bar

� Adaptable to many wall finishes, including drywall and tile. � 491 systems designed for renovations and surface mount

installations lowering on-site installation costs.

A07 Wall/Wall (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

481-A07-050 2" 51 1 1/4" 32 * * 5 3/4" 146 * * 9/16" 14 1" 25481-A07-075 3" 76 1 1/4" 32 * * 6 3/4" 171 * * 1 1/2" 38 1 1/2" 38481-A07-100 4" 102 1 1/4" 32 * * 7 3/4" 197 * * 2" 51 2" 51481-A07-150 6" 152 1 1/4" 32 * * 9 3/4" 248 * * 2 1/2" 64 3" 76481-A07-200 8" 203 1 1/4" 32 * * 13" 330 * * 4" 102 4" 102481-A07-300 12" 305 1 1/4" 32 * * 19" 483 * * 6" 152 6" 152491-A07-050 2" 51 5/8" 16 * * 5 3/4" 146 * * 9/16" 14 1" 25491-A07-075 3" 76 5/8" 16 * * 6 3/4" 171 * * 1 1/2" 38 1 1/2" 38491-A07-100 4" 102 5/8" 16 * * 7 3/4" 197 * * 2" 51 2" 51491-A07-150 6" 152 5/8" 16 * * 9 3/4" 248 * * 2 1/2" 64 3" 76491-A07-200 8" 203 5/8" 16 * * 13" 330 * * 4" 102 4" 102491-A07-300 12" 305 5/8" 16 * * 19" 483 * * 6" 152 6" 152

Wall to CornerWall to Ceiling

481-A09-050 2" 51 1 1/4" 32 * * 3 7/8" 98 * * 1/2" 13 1/2" 13481-A09-075 3" 76 1 1/4" 32 * * 4 7/8" 124 * * 3/4" 19 3/4" 19481-A09-100 4" 102 1 1/4" 32 * * 5 7/8" 149 * * 1" 25 1" 25481-A09-150 6" 152 1 1/4" 32 * * 7 7/8" 200 * * 1 1/2" 38 1 1/2" 38481-A09-200 8" 203 1 1/4" 32 * * 10 1/2" 267 * * 2" 51 2" 51481-A09-300 12" 305 1 1/4" 32 * * 15 1/2" 394 * * 3" 76 3" 76491-A09-050 2" 51 5/8" 16 * * 3 7/8" 98 * * 1/2" 13 1/2" 13491-A09-075 3" 76 5/8" 16 * * 4 7/8" 124 * * 3/4" 19 3/4" 19491-A09-100 4" 102 5/8" 16 * * 5 7/8" 149 * * 1" 25 1" 25491-A09-150 6" 152 5/8" 16 * * 7 7/8" 200 * * 1 1/2" 38 1 1/2" 38491-A09-200 8" 203 5/8" 16 * * 10 1/2" 267 * * 2" 51 2" 51491-A09-300 12" 305 5/8" 16 * * 15 1/2" 394 * * 3" 76 3" 76

Larger sizes available

W

H1

W

H1

SW

H1

SW

H1

481 - A07 Wall/Wall Ceiling/Ceiling (4" (100mm) system shown)

491 - A07 Wall/Wall Ceiling/Ceiling (4" (100mm) system shown)

492 - A09 (6" (150mm) system shown)

A09 Wall/Corner (2" (51mm) system shown)

% OF MOVEMENT±50%

VAPOR BARRIERoptional

JOINT WIDTH1" (25mm) – 12" (300mm)

FIRE RATEDoptional

Clear anodized finish standard on these systems. Provides for a tough, durable finish that is easy to clean.

WS

H1

Application SystemW H1 S B Movement +/-

Joint Width Frame Height 1 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm

Wall to Wall318-A07-050 2" 51 5/8" 16 1/8" 3 * * 1" 25 1/2" 13318-A07-075 3" 76 5/8" 16 1/8" 3 * * 1 1/2" 38 3/4" 19318-A07-100 4" 102 5/8" 16 1/8" 3 * * 2" 51 1" 25

Wall to Corner318-A09-050 2" 51 5/8" 16 1/8" 3 * * 1" 13 1/2" 13318-A09-075 3" 76 5/8" 16 1/8" 3 * * 1 1/2" 38 3/4" 19318-A09-100 4" 102 5/8" 16 1/8" 3 * * 2" 51 1" 25

42

Page 23: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 45inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Surface Mount

Wall and Ceiling Systems

811 Series – Variable Degree Cover � Unique ratcheted design accommodates uneven or odd angle

wall conditions. � Economical solution for retrofit/surface mount installations. � Snap-fit design for easy on-site assembly. � Clear anodized finish standard.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

811-A07-025 1" 25 3/8" 10 * * 3 1/8" 79 * * 1/2" 13 * *811-A07-050 2" 51 3/8" 10 * * 4 5/8" 117 * * 1" 25 * *811-A07-075 3" 76 3/8" 10 * * 6 1/8" 156 * * 1 1/2" 38 * *811-A07-100 4" 102 3/8" 10 * * 7 5/8" 194 * * 2" 51 * *

Wall to CornerWall to Ceiling

811-A09-025 1" 25 3/8" 10 * * 1 3/4" 44 * * 1/4" 6 * *811-A09-050 2" 51 3/8" 10 * * 3 1/4" 83 * * 1/2" 13 * *811-A09-075 3" 76 3/8" 10 * * 4 3/4" 121 * * 3/4" 19 * *811-A09-100 4" 102 3/8" 10 * * 6 1/4" 159 * * 1" 25 * *

A07 Wall/Wall Ceiling/Ceiling (1" (25mm) system shown)

SW

H1

A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown)

811-A09-050

SW

H1

A07 Wall/Wall (2" (51mm) system shown)

118 Series

104 Series

104 | 118 Seal � Dual durometer seal provides secure fit and optimal flexibility. � Designed for renovation and surface mount installations

(104 system). � Clear anodized finish standard. � Flush mount frame reduces sightline (118 system). � Adaptable to any wall finish.

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

104-A07-025 1" 25 * * * * 4 3/4" 121 * * 1/4" 6 1/4" 6104-A07-038 1 1/2" 38 * * * * 5 1/8" 130 * * 3/8" 10 3/8" 10104-A07-050 2" 51 * * * * 5 5/8" 143 * * 1/2" 13 1/2" 13104-A07-075 3" 76 * * * * 6 5/8" 168 * * 3/4" 19 3/4" 19

Wall to CornerWall to Ceiling

104-A09-025 1" 25 * * * * 2 7/8" 73 * * 1/4" 6 1/4" 6104-A09-038 1 1/2" 38 * * * * 3 5/16" 84 * * 3/8" 10 3/8" 10104-A09-050 2" 51 * * * * 3 3/4" 95 * * 1/2" 13 1/2" 13104-A09-075 3" 76 * * * * 4 3/4" 121 * * 3/4" 19 3/4" 19

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to Wall 118-A07-050 2" 50 * * * * 1 7/8" 47 * * 1/2" 13 1/2" 13118-A07-075 3" 75 * * * * 2 7/8" 73 * * 3/4" 19 3/4" 19

Wall to Corner 118-A09-050 2" 50 * * * * 1 7/8" 47 * * 1/2" 13 1/2" 13118-A09-075 3" 75 * * * * 2 7/8" 73 * * 3/4" 19 3/4" 19

SW

S

W

SW

% OF MOVEMENT±25% to ±50%

VAPOR BARRIERoptional

JOINT WIDTH1" (25mm) – 4" (175mm)

FIRE RATEDoptional

Cost effective solutions for the many conditions encountered in interior walls.

804 Series – Cover Plate � Economical solution for retrofit/surface mount installations. � Spring clip design for easy on-site installation. � Seamlessly integrates with 804-A01/A02 flooring system. � Clear anodized finish standard.

A09 Wall/Corner Wall/Ceiling (1" (25mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

SW

H1

SW

H1

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to Floor804-A01-025 1" 25 1/8" 4 * * 3" 76 * * 1/4" 6 1/8" 3804-A01-038 1 1/2" 38 1/8" 4 * * 3" 76 * * 3/8" 10 1/8" 3804-A01-050 2" 51 1/8" 4 * * 4" 114 * * 1/2" 13 1/8" 3

Floor to Wall804-A02-025 1" 25 1/8" 4 * * 2" 50 * * 1/4" 6 1/8" 3804-A02-038 1 1/2" 38 1/8" 4 * * 2" 50 * * 3/8" 10 1/8" 3804-A02-050 2" 51 1/8" 4 * * 3 1/4" 83 * * 1/2" 13 1/8" 3

44

Page 24: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 47inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Protect appearances by making expansion joints

disappear with our exterior joint systems. We've

mastered this with our new 601 Series ideal for high-

end exteriors because it integrates seamlessly with all

types of building envelopes so there's no sightline.

Exterior Joint Systems

ProjectTulsa Technology Center, Tulsa Tech – Tulsa, Oklahoma

ChallengeCrafton Tull & Associates designed the 170,000-square-foot Technology Center, featuring labs, lecture classrooms, administrative spaces, conference and meeting spaces, media center, and a cafe. While the architectural joint systems were a straightforward quote-bid-award aspect of the project, the challenge was finding a company that could deliver on time and on budget.

SolutionJointMaster™ carries an extensive inventory of expansion joint system materials – from aluminum frames and covers to hardware and snap-in-place seals. For the Tulsa Tech project, JointMaster used its broad knowledge of expansion control engineering to modify off-the shelf products that fit the project’s parameters. The result was joint systems delivered to the jobsite faster than any other supplier.

Project Profile

Tulsa Tech

46

Page 25: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 49inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Flush Mount

Exterior Joint Systems

601 Series – Flush Mount A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

Closed/Nominal Position Operational Position

Application SystemW1 W2 H1 S1 S2 Thermal Movement +/- Seismic Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Sightline Horiz. Vert. Horiz. Vert.US mm US mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

601-A07/A09-300 12" 305 17 1/2" 445 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 6" 152601-A07/A09-450 18" 457 23 1/2" 597 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 9" 229601-A07/A09-600 24" 610 29 1/2" 749 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 12" 305

System available in any variation of size for 10” (250mm) -30” (750mm) expansion gaps

% OF MOVEMENT±50%

VAPOR BARRIERoptional

JOINT WIDTH1" (25mm) – 12"(300mm)

FIRE RATEDoptional

"Stealth" Series � The Hinged Cover plate or ”pan” can be infilled with adjacent

Architectural systems to disguise the expansion joint (Glazing, Metal panels and the Masonry units such as Stone and Brick).

� Ideal system for use on high-end exterior systems or conditions where the structural joint is located in a high profile position on the building veneer.

� Flush mounted exterior system reduces sightline to two reveals of approximately 1" and 3" dimensions.

� System is seismic-capable while allowing for daily thermal movement and wind sway considerations.

� Compression spring shock absorbtion assembly correctly reposition the pan to the normal position after a system movement.

A07 Wall/Wall (2" (51mm) system shown)

A09 Wall/Corner (2" (51mm) system shown)

* Available with center bar (652)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

651-A07-025 1" 25 1 1/4" 32 * * 4 1/4" 108 * * 1/2" 13 1/2" 13651-A07-050 2" 51 1 1/4" 32 * * 5 1/4" 133 * * 1" 25 1" 25651-A07-075 3" 76 1 1/4" 32 * * 6 1/4" 159 * * 1 1/2" 38 1 1/2" 38651-A07-100 4" 102 1 1/4" 32 * * 7 1/4" 184 * * 2" 51 2" 51651-A07-150 6" 152 1 1/4" 32 * * 10 1/2" 267 * * 3" 76 3" 76651-A07-200 8" 203 1 1/4" 32 * * 13 1/2" 343 * * 4" 102 4" 102651-A07-300 12" 305 1 5/16" 33 * * 19 1/2" 495 * * 6" 152 6" 152

Wall to CornerWall to Ceiling

651-A09-025 1" 25 1 1/4" 32 * * 2 5/8" 67 * * 1/2" 13 1/2" 13651-A09-050 2" 51 1 1/4" 32 * * 3 5/8" 92 * * 1" 25 1" 25651-A09-075 3" 76 1 1/4" 32 * * 5" 127 * * 1 1/2" 38 1 1/2" 38651-A09-100 4" 102 1 1/4" 32 * * 6 1/2" 165 * * 2" 51 2" 51651-A09-150 6" 152 1 1/4" 32 * * 9 1/2" 241 * * 3" 76 3" 76651-A09-200 8" 203 1 1/4" 32 * * 12 1/2" 318 * * 4" 102 4" 102

Larger sizes available

651-A07-050

SW

H1

651-A09-050

SW

H1

Surface Mount

Exterior Joint Systems

651 Series – Surface Mount � Surface mount frame accommodates uneven joint widths. � Rubberized washers prevent the elements from penetrating the

cover plate at anchor points. � Factory formed transitions available. � Mill finish standard – custom finishes available per page 7.

48

Page 26: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 51inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Centering Bar

Exterior Joint Systems

616 | 621 � Industry unique seal profile holds tight, linear lines. � Linear Santoprene™ seal design allows for fluid seismic movement

during joint expansion and contraction. � Field heat weldable Santoprene seals for weather tight seams

and crisp transitions. � Seal walls are among the thickest in the industry allowing our

product to be used in soffits and corridor ceilings with no sagging.

621 Series – Surface Mount

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to Wall

616/612-A07-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102616/612-A07-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127616/612-A07-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152616/612-A07-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229616/612-A07-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305

Wall to Corner

616/612-A09-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102616/612-A09-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127616/612-A09-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152616/612-A09-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229616/612-A09-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305

Larger sizes available

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to Wall

621-A07-200 8" 200 3" 75 * * 12" 300 * * 4" 102 4" 102621-A07-250 10" 250 3" 75 * * 14" 350 * * 5" 127 5" 127621-A07-300 12" 300 3" 75 * * 16" 400 * * 6" 152 6" 152621-A07-450 18" 450 3" 75 * * 22" 550 * * 9" 229 9" 229621-A07-600 24" 600 3" 75 * * 28" 700 * * 12" 305 12" 305

Wall to Corner

621-A09-200 8" 200 3" 75 * * 10" 250 * * 4" 102 4" 102621-A09-250 10" 250 3" 75 * * 12" 300 * * 5" 127 5" 127621-A09-300 12" 300 3" 75 * * 14" 350 * * 6" 152 6" 152621-A09-450 18" 450 3" 75 * * 20" 500 * * 9" 229 9" 229621-A09-600 24" 600 3" 75 * * 26" 650 * * 12" 305 12" 305

Larger sizes available

S

W

H1

616-A07 Wall/Wall, Ceiling/Ceiling (12" (300 mm) system shown)

A07 Wall/Wall, Ceiling/Ceiling (12" (300 mm) system shown)

616 Series – Flush Mount

% OF MOVEMENT±50%

VAPOR BARRIERoptional EPDM (612)

Integral Backseal (616/621)

JOINT WIDTH8" (200mm) – 24" (600mm)

FIRE RATEDoptional

612-A07 Wall/Wall, Ceiling/Ceiling (12" (300 mm) system shown)

A07 Wall/Wall (2" (51mm) system shown)

A09 Wall/Corner (3" (75mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to Ceiling

620-A07-050 2" 51 2 3/8" 60 * * 5 13/16" 148 * * 1" 25 1" 25620-A07-075 3" 76 2 3/8" 60 * * 6 13/16" 173 * * 1 1/2" 38 1 1/2" 38620-A07-100 4" 102 2 3/8" 60 * * 7 13/16" 198 * * 2" 51 2" 51620-A07-150 6" 152 2 3/8" 60 * * 9 13/16" 249 * * 3" 76 3" 76

Wall to CornerWall to Ceiling

620-A09-050 2" 51 2 3/8" 60 4 3/8" 111 3 7/8" 98 * * 1" 25 1" 25620-A09-075 3" 76 2 3/8" 60 4 3/8" 111 4 7/8" 124 * * 1 1/2" 38 1 1/2" 38620-A09-100 4" 102 2 3/8" 60 4 3/8" 111 5 7/8" 149 * * 2" 51 2" 51620-A09-150 6" 152 2 3/8" 60 4 3/8" 111 7 7/8" 200 * * 3" 76 3" 76

SW

H1

SW

H1

H2

Surface Mount

Exterior Joint Systems

620 Series – Surface Mount � Surface mount frame design eases installation in

narrow joints and wall to corner conditions. � Mill finish standard.

A09 Wall/Corner Wall/Ceiling (3" (75mm) system shown)

A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown)

SW

H1

SW

H1

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Wall to WallCeiling to CeilingCorner to Corner

615-A07-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25615-A07-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38615-A07-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51615-A07-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76

Wall to CornerWall to Ceiling

615-A09-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25615-A09-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38615-A09-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51615-A09-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76

615 Series – Flush Mount � Pleated Santoprene seal design allows for fluid

seismic movement. � Throat mount brackets reduce sightline to width of

seal only.

S

H1

W

50

Page 27: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 53inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Roof

Exterior Joint Systems

661 – 45° Curb Mounted � Frame angled to assist in securing roofing

membrane down on 45° curb. � Moisture barrier included. � Weather washers prevent leaking where

fasteners penetrate frames or covers. � Factory preformed transitions available. � Available finish options on page 7 .

672 | 674 Bellows � Remains watertight during severe seismic movement. � Splicing kits available for simple installation. � Flanges available standard as galvanized optional stainless steel,

copper, aluminum and EPDM as well. � Expansion joints intersect and change directions. Ensure

maximum flexibility, clean lines, and waterproofing in these critical areas.

661 Series – Curb Mounted Centering Bar A01 Roof/Roof (2" (51mm) system shown)

A02 Roof/Wall (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Roof to Roof

661-A01-025 1" 25 1 1/4" 32 * * 4 1/4" 108 8 3/8" 213 1/2" 13 1/2" 13661-A01-050 2" 51 1 1/4" 32 * * 5 1/4" 133 8 7/8" 225 1" 25 1" 25661-A01-075 3" 76 1 1/4" 32 * * 6 1/4" 159 9 5/8" 244 1 1/2" 38 1 1/2" 38661-A01-100 4" 102 1 1/4" 32 * * 7 1/4" 184 10 5/8" 270 2" 51 2" 51661-A01-150 6" 152 1 1/4" 32 * * 10 1/2" 267 12 1/8" 308 3" 76 3" 76661-A01-200 8" 203 1 1/4" 32 * * 13 1/2" 343 14 1/8" 359 4" 102 4" 102661-A01-300 12" 305 1 3/8" 35 * * 19 1/2" 495 18 1/8" 460 6" 152 6" 152

Roof to Wall

661-A02-025 1" 25 1 1/4" 32 * * 2 5/8" 67 4 5/8" 117 1/2" 13 1/2" 13661-A02-050 2" 51 1 1/4" 32 * * 3 5/8" 92 5 3/8" 137 1" 25 1" 25661-A02-075 3" 76 1 1/4" 32 * * 5" 127 6 3/8" 162 1 1/2" 38 1 1/2" 38661-A02-100 4" 102 1 1/4" 32 * * 6 1/2" 165 7 3/8" 187 2" 51 2" 51661-A02-150 6" 152 1 1/4" 32 * * 9 1/2" 241 9 3/8" 238 3" 76 3" 76661-A02-200 8" 203 1 1/4" 35 * * 12 1/2" 318 11 3/8" 289 4" 102 4" 102

S

W

H1

S

W

H1

*Available with center bar (662)

% OF MOVEMENT±50%

VAPOR BARRIERIncluded (661), Optional (672)

JOINT WIDTH1" (25mm) – 12"(300mm)

FIRE RATEDoptional

672 Series – Bellows/Canted Roof G01 Canted Roof/Roof (2" (51mm) system shown)

G02 Canted Roof/Wall (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Roof to Roof

672-G01-050 2" 51 * * * * * * * * 1" 25 1" 25672-G01-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38672-G01-100 4" 102 * * * * * * * * 2" 51 2" 51672-G01-150 6" 152 * * * * * * * * 3" 76 3" 76672-G01-200 8" 203 * * * * * * * * 4" 102 4" 102

Roof to Wall

672-G02-050 2" 51 * * * * * * * * 1" 25 1" 25672-G02-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38672-G02-100 4" 102 * * * * * * * * 2" 51 2" 51672-G02-150 6" 152 * * * * * * * * 3" 76 3" 76672-G02-200 8" 203 * * * * * * * * 4" 102 4" 102

672-A02-050

W W

674 Series – Bellows/Curb Flange G01 Curb Flange Roof/Roof (2" (51mm) system shown)

G02 Curb Flange Roof/Wall (2" (51mm) system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Roof to Roof

674-G01-050 2" 51 * * * * * * * * 1" 25 1" 25674-G01-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38674-G01-100 4" 102 * * * * * * * * 2" 51 2" 51674-G01-150 6" 152 * * * * * * * * 3" 76 3" 76674-G01-200 8" 203 * * * * * * * * 4" 102 4" 102

Roof to Wall

674-G02-050 2" 51 * * * * * * * * 1" 25 1" 25674-G02-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38674-G02-100 4" 102 * * * * * * * * 2" 51 2" 51674-G02-150 6" 152 * * * * * * * * 3" 76 3" 76674-G02-200 8" 203 * * * * * * * * 4" 102 4" 102

W W

662-A02 Roof/Wall (2" (51mm) system shown)

Exterior roof systems available in standard hard-lid aluminum covers as well as flexible, closed cell EPDM bellows configurations.

52

Page 28: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 55inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Roof

Exterior Joint Systems

691 Series – Vertical Curb Mount

Available Transitions

A01 Roof/Roof (2" (51mm) system shown)

A02 Roof/Wall (2" (51mm) system shown)

Application SystemW H1 S B Movement +/-

Joint Width Frame Height 1 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm

Roof to Roof

691-A01-025 1" 25 1 1/4" 32 4 1/4" 108 8 3/8" 213 1/2" 13 1/2" 13691-A01-050 2" 51 1 1/4" 32 5 1/4" 133 8 7/8" 225 1" 25 1" 25691-A01-075 3" 76 1 1/4" 32 6 1/4" 159 9 5/8" 244 1 1/2" 38 1 1/2" 38691-A01-100 4" 102 1 1/4" 32 7 1/4" 184 10 5/8" 270 2" 51 2" 51691-A01-150 6" 152 1 1/4" 32 10 1/2" 267 12 1/8" 308 3" 76 3" 76691-A01-200 8" 203 1 1/4" 32 13 1/2" 343 14 1/8" 359 4" 102 4" 102691-A01-300 12" 305 1 3/8" 35 19 1/2" 495 18 1/8" 460 6" 152 6" 152

Roof to Wall

691-A02-025 1" 25 1 1/4" 32 2 5/8" 67 4 5/8" 117 1/2" 13 1/2" 13691-A02-050 2" 51 1 1/4" 32 3 5/8" 92 5 3/8" 137 1" 25 1" 25691-A02-075 3" 76 1 1/4" 32 5" 127 6 3/8" 162 1 1/2" 38 1 1/2" 38691-A02-100 4" 102 1 1/4" 32 6 1/2" 165 7 3/8" 187 2" 51 2" 51691-A02-150 6" 152 1 1/4" 32 9 1/2" 241 9 3/8" 238 3" 76 3" 76691-A02-200 8" 203 1 1/4" 35 12 1/2" 318 11 3/8" 289 4" 102 4" 102

� Metal and EPDM-Bellow Joint transitions available – Consult with your Sales Representative to determine which of our dozens of configurations apply to your unique building conditions.

Building expansion joint slab and wall openings

inherently create a pathway for fire and smoke

to travel through. JointMaster’s line of Fire Barrier

products provide protection for 2, 3, and 4-hour

rated conditions.

Fire Barriers

54

Page 29: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 57inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

900-FB – Fire Blankets � Offers better packaging and better lead times than

the competition. � 2 hour rated meeting UL2079, ASTN E-1399, ASTM E-1966. � Meets “Hose Stream Test” for vertical wall applications. � ±50% seismic movement. � Installs with retaining flanges. � Accommodates joint widths from 1" (25mm) to 24" (600mm). � Chase wall covers available.

(2" (51mm) floor system shown) (Applied to 301-A01 system)

HEX HEAD CONCRETE SCREW

20 GA. GALVANIZED RETAINER

GALVANIZED STEELRETAINING FLANGE

MAIN BARRIERHEAT SHIELD

Surface Mount

Low Profile

4" (102mm) 221-A01 floor system shown950 – Fire Blankets � Available for joint sizes 12" (300mm) -32" (800mm). � Custom sizes available. � 2 hour rated meeting UL2079, ASTM E-1399, ASTM E-1966. � Accommodates joint widths from 1" (25mm) to 24" (600mm).

4"(102mm) 221-A01 floor system shown

GALVANIZED STEELFLANGE

(1" (25mm) floor system shown) (Applied to 106-A01 system)

REACTOFIRE MINERAL WOOL ANDSILICONE SEALANT FIRE BARRIER SYSTEM(OPTIONAL)

925 MINERAL WOOL

921 SILICONE SEALANT

3" (76mm) 105-A01 Floor System Shown

4" (102mm) 757-A01 Floor System Shown(Available only for 975)

920 – Firestop System 921, 925, 935 Mineral Wool and Sealant

� Cost effective system for joint widths up to 3” (127mm).

� Mineral wool supplied in 4' (1.2m) lengths and compressed into gap for easy installation.

� Up to 3 hour rated meeting UL2079. � System accommodates horizontal movement

to 20%. � Meets “Hose Stream Test" for masonry walls.

975 – FB Fire Blankets � Patented, UL-Rated bottom mount design. � No interference between Fire Barrier and cover. � Allows for higher hourly rated blankets to mount under

smaller openings. � 975 series are the easiest systems to install that we offer

and provide great savings. � Utilizes male/female connections. � Optional water guard. � Assists in protecting the barrier in wet

construction environments.

NEW! 990 – Fire Rated Foam � Provides a 2 hour fire rating in accordance with UL-2079. � 990 system does not rely on the silicone face for its rating. The

foam is impregnated with fire retardant material, meaning the rating is not compromised due to vandalism or damage to the silicone face.

� Fire foam seals are water tight and also have sound attenuation qualities.

� This system is coated on both sides so either face can be exposed.

� Seal material is UV stable, and resistant to solvents. � Capable of handling vertical and horizontal joint movement. � Open cell foam is constantly self-expanding, allowing system

to maintain a watertight seal while undergoing rapid joint movement.

� 990 foam seal comes pre-compressed for installation ease. � System is available in 13 standard colors (custom

colors available).

Bottom Mount

4"(102mm) 757-A01 floor system shown

GALVANIZED STEEL FLANGE

1/4" DRAIN TUBE 30' ON CENTER

3"(76mm) 105-A01 floor system shown

EXPANDED GALVANIZEDMETAL FLANGE

Intertek tested to globally recognized standards and Los Angeles Research Record (LARR) approved (U.L. Equivalent)

900 Series

Fire Barriers

Firebarrier configurations available to meet any project’s needs.

Building expansion joint and slab openings inherently create a pathway for fire and smoke to travel and spread throughout the structure. JointMaster’s broad array of Fire Barrier products provide protection for 2, 3, and 4-hour rated conditions to keep the threat contained.

56

Page 30: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 59inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Moisture Deterrent Membranes

Vapor Barrier

NEW! Insulated Vapor Barrier � Exterior grade system capable of matching 50% joint movement. � Consists of Fiber-reinforced EPDM membranes sandwiching

commercial grade insulation adhered and pinned together to form a seimic-capable assembly.

� Maintains a minimum R-Value of 15. � Seams and directional transitions designed to ensure a

watertight seal and positive condensation drainage.

Standard Vapor Barrier � High performance, Fiber-reinforced EPDM membrane � Provided in conjunction with all exterior joints, also available as an

additional feature to our complete line of products

� Allows for joint movement matching the requirements of the Architectural Joint cover

� Durable .045 thk. sheetgood resists tearing, puncture, and wear-through

With EJ cover frames With termination bar

Application SystemW

Joint WidthH

Insulated Vapor Barrier DepthMovement ±

Compression/ExpansionUS mm US mm US mm

JLWall to Wall

Wall to CornerRoof to RoofRoof to Wall

JL06-IVB 6” 152 5” 127 3” 76JL08-IVB 8" 203 6” 152 4” 102

JL010-IVB 10” 254 7” 178 5” 127JL012-IVB 12” 305 8” 203 6” 152JL018-IVB 18” 457 10" 457 9” 229JL024-IVB 24” 610 12” 305 12” 305JL028-IVB 28” 711 14” 356 14” 356

Appox. 1 1/2" [38mm]Under FrameW

H

Fastener @12" [305mm] O.C. (By Others)

W

H

Termination Bar 1" [25mm] Widew/ 3/16" [4.8mm] Holes

Vapor barriers are designed to resist the penetration of moisture through wall, ceiling and floor assemblies of a structure. JointMaster’s systems are designed to meet the challenges of keeping the elements where they belong- outside. Our membranes deter air currents, wind-driven rain, and ensure for the weep of condensation to the exterior.

BR Series – Seal � Intended for use on smaller joint

Deck/Deck (2" (51mm) system shown)

Application System Nominal Joint Width Minimum Joint Width Maximum Joint WidthH1 H2

Seal Height Seal DepthUS mm US mm US mm US mm US mm

ArchitecturalCompression

Seals

BR-125 1 1/4" 32 1" 25 1 3/4" 45 2" 51 2 1/8" 54

BR-150 1 1/2" 38 1" 25 2" 51 2 3/8" 60 2 1/2" 64

BR-175 1 3/4" 45 1 1/8" 29 2 1/8" 54 2 1/2" 64 2 5/8" 67BR-200 2" 51 1 3/8" 35 2 1/2" 64 3 1/4" 83 3 3/8" 86BR-225 2 1/4" 57 1 5/8" 41 3" 76 3 1/2" 89 3 5/8" 92BR-250 2 1/2" 64 1 3/4" 45 3 3/8" 64 4" 102 4 1/8" 105

Parking and Open Structure

Compression Seals

NEW! – AR Series – Seal � Heavy pedestrian/ moderate vehicle loading capabilities � Incorporation of ribs on side faces to aid in pooling epoxy

and adding surface area for increased adhesion to deck � Installed with 2-part epoxy � Appropriate for horizontal and vertical applications

Deck/Deck (2" (51mm) system shown)

Decking Systems � Industry unique, patented design creates crisp, linear sightlines

eliminating the waviness encountered on many systems on the market today

� Profile engineered for improved ease of installation reducing labor costs

� Comprised of Santoprene (TPV) Rubber providing superior movement and rigidity

� Heat weldable for watertight seams and transitions � Highly resistant to UV degradation, extreme temperatures, and

chemicals � ADA compliant designs

Application System Nominal Joint Width Minimum Joint Width Maximum Joint WidthH1 H2

Seal Height Seal DepthUS mm US mm US mm US mm US mm

ArchitecturalCompression

Seals

AR-200S 2" 50 1 1/2" 38 2 1/2" 57 2 3/16" 56 2 3/16" 59

AR-300S 3" 75 2 1/4" 57 3 1/2" 89 3 5/16" 84 3 7/16" 87

AR-400S 4" 100 3" 76 5" 127 3 5/16" 84 3 7/16" 87

W

H1

58

Page 31: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 61inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

Our Foam Seal products are 100% weather tight, UV

resistant and ideal for roof applications and under

metal cover plate systems. 100% weather tight and

UV resistant.

Foam Seals

NEW! – CR Series – Seal � Heavy duty and vehicular applications � Installed with primer/tackcoat and Elastomeric

concrete header for secure placement

Deck/Deck (2" (51mm) system shown)

Application System Nominal Joint Width Minimum Joint Width Maximum Joint Width

B H1 H2

Blockout Seal Height Seal DepthUS mm US mm US mm US mm US mm

ArchitecturalCompression

Seals

CR-200S 2" 50 1 1/2" 38 2 1/2" 57 2" 50 2 3/16" 56 2 3/16" 59

CR-300S 3" 75 2 1/4" 57 3 1/2" 89 2" 50 3 5/16" 84 3 7/16" 87

CR-400S 4" 100 3" 76 5" 127 2" 50 3 5/16" 84 3 7/16" 87

H1

W

Foam Seals – Color Match � Acrylic, elastomeric paint can be applied to either the 1100/1150 foam seal. � A field applied protective coating can match any Sherwin-Williams® or Pantone® color. � Coating matches foam seals flexibility traits preventing cracking during joint movement. � The coating is resistant to weathering, oxidation, UV degradation, and salt corrosion. � Best used in vertical applications. � Ideal for commercial buildings, stadiums and plazas where a

cost effective finish is important. � Can match custom colors when a color

sample is submitted. � Time tested resistance to fading

and cracking in interior and exterior applications.

Silicone Seal Colors

Precast White Limestone

Natural Stone Sandstone

Adobe Tan Dusty Rose

Rustic Brick Blue Spruce

Gray Bronze

Charcoal Black

Due to the printing process, actual color may vary.

60

Page 32: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro 63inprocorp.com/jointmaster | Buy online and download BIM objects, specifications and installation instructions

ENG

INEERED

META

L PROD

UCTS

W

H1

Foam Seals

1100 Series – Seal � High heat, weather, and UV resistant. � 100% watertight foam seal. � Excellent for roof applications and under metal

cover plate systems. � Allows for 30% Tension | 60% Compression |

100% Shear movement.

(2" (51mm) system shown)

(2" (51mm) system shown)

W

H1

1100, 1150, 1175 Series JOINT WIDTH

3⁄4" (19mm)- 12"(300mm)VAPOR BARRIER

Not RequiredFIRE RATED

optional

NEW! 1175 Series – Seal � Developed to meet DOT performance

requirements � Allows for 100% shear movement � Seal is UV stable and resistant to solvents

and fuels � Arrives to site pre-compressed and is

installed with epoxy

Application System Joint Width Seal HeightMovement ±

Compression/ExpansionUS mm US mm US mm

1175Wall to Wall

Wall to Corner

1175-100 1" 25 1 1/2” 38 1/2” 13

1175-200 2” 51 2” 51 1” 25

1175-300 3” 76 3” 76 1 1/2” 38

1175-400 4” 102 4” 102 2" 51

1175 Series Floor/Floor (2” (50mm) system shown)

(OPTIONAL)FIRE BARRIER: SELF-LEVELING SEALANT AND MINERAL WOOL SHOWN

SealHeight

1175SERIES

JointWidth

1175SERIES

Application SystemNominal Joint Width Seal Height

Movement + / -

Compression Expansion

US mm US mm US mm US mm

1100Wall to Wall

Wall to Corner

1100-100 1" 25 2” 51 .4” 10 1.8” 461100-150 1 1/2” 38 2” 51 .8” 20 2.6” 661100-200 2” 51 2” 51 1.1” 27 3.6” 911100-250 2 1/2” 64 2" 51 1.3” 33 4.2” 1071100-300 3” 76 3” 76 1.6” 40 5.2” 1321100-350 3 1/2” 89 3” 76 1.8” 46 5.8” 1471100-400 4” 102 4” 101 2” 51 6.5” 1651100-450 4 1/2” 114 4” 101 2.2” 56 7.3” 1851100-500 5” 127 4” 101 2.5” 64 8.1” 206

Other sizes available

Application SystemNominal Joint Width Seal Height

Movement + / -

Compression Expansion

US mm US mm US mm US mm

1150Wall to Wall

Wall to Corner

1150-100 1" 25 2” 51 .5” 13 1.25” 321150-200 2” 51 2” 51 1’ 25 2.5” 641150-300 3” 76 3” 76 1.5” 38 3.75” 951150-400 4” 102 4” 101 2” 51 5” 1271150-500 5” 127 4” 101 2.5” 64 6.25” 1591150-600 6” 152 5” 127 3” 76 7.5” 1911150-700 7” 178 5” 127 3.5” 83 8.75” 2221150-800 8” 203 5” 127 4” 89 10 254

1150 Series – Seal � Chemical, weather, and UV resistant. � 100% watertight foam seal. � Excellent when in contact with grade or oils. � Allows for 25% Tension | 50% Compression | 100% Shear movement. � Ridged sides trap and pool epoxy (JPR003) providing superior adhesion

to the joint surface to resist imposed loads.

Foam Seals

(2" (51mm) system shown)1250 Series Seal � Foam seals create a water tight, insulated seal. � Seal material is UV stable and highly resistant to ozone

and chemical degradation. � Capable of handling vertical and horizontal

joint movement. � Available in 13 standard colors, custom colors available

upon request. See page 61. � 1250 system is compressed in field and installed

utilizing silicone or epoxy adhesive (supplied by others). � Can be permanently adhered to joint edge

using epoxy.

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor/FloorFloor/WallWall/Wall

Wall/Corner

1250-050 1/2" 13 1 1/2" 38 * * * * * * 1/8" 3 1/8" 31250-100 1" 25 1 1/2" 38 * * * * * * 1/4" 6 1/4" 61250-150 1 1/2" 38 2" 51 * * * * * * 3/8" 9 3/8" 91250-200 2" 51 2" 51 * * * * * * 1/2" 13 1/2" 131250-250 2 1/2" 64 2" 51 * * * * * * 5/8" 16 5/8" 161250-300 3" 76 3" 76 * * * * * * 3/4" 20 3/4" 201250-350 3 1/2" 89 3" 76 * * * * * * 7/8" 22 7/8" 221250-400 4" 102 4" 102 * * * * * * 1" 25 1" 251250-500 5" 127 4" 102 * * * * * * 1 1/4" 32 1 1/4" 321250-600 6" 152 4" 102 * * * * * * 1 1/2" 38 1 1/2" 381250-700 7" 179 4" 127 * * * * * * 1 3/4" 44 1 3/4" 441250-800 8" 203 4" 127 * * * * * * 2" 52 2" 52

Other sizes available

1200, 1250 Series

2 3/16"(60mm)

1200SERIESW

W

2 3/16"(60mm)

1250SERIES

W

CURTAIN WALL STOREFRONT(BY OTHERS)

W

CURTAIN WALL STOREFRONT(BY OTHERS)

1200 Series(2" (50mm) system shown)

1250 Series(2" (50mm) system shown)

1200 Series(2" (50mm) double-sided system shown)

1250 Series(2" (50mm) double-sided system shown)

W

CURTAIN WALL STOREFRONT(BY OTHERS)

1250 Series(2" (50mm) Custom triple-sided system shown)

2 3/16"(60mm)

1200SERIESW

W

2 3/16"(60mm)

1250SERIES

W

CURTAIN WALL STOREFRONT(BY OTHERS)

W

CURTAIN WALL STOREFRONT(BY OTHERS)

1200 Series(2" (50mm) system shown)

1250 Series(2" (50mm) system shown)

1200 Series(2" (50mm) double-sided system shown)

1250 Series(2" (50mm) double-sided system shown)

W

CURTAIN WALL STOREFRONT(BY OTHERS)

1250 Series(2" (50mm) Custom triple-sided system shown)

(2" (50mm) system shown) (2" (50mm) double-sided system shown)

Application SystemW H1 H2 S B Movement +/-

Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal VerticalUS mm US mm US mm US mm US mm US mm US mm

Floor to FloorFloor to WallWall to Wall

Wall to Corner

1200-050 1/2" 13 1 1/2" 38 * * * * * * 1/4" 6 1/4" 61200-100 1" 25 1 1/2" 38 * * * * * * 1/2" 13 1/2" 131200-150 1 1/2" 38 2" 51 * * * * * * 3/4" 20 3/4" 201200-200 2" 51 2" 51 * * * * * * 1" 25 1" 251200-250 2 1/2" 64 2" 51 * * * * * * 1 1/4" 32 1 1/4" 321200-300 3" 76 3" 76 * * * * * * 1 1/2" 38 1 1/2" 381200-350 3 1/2" 89 3" 76 * * * * * * 1 3/4" 44 1 3/4" 441200-400 4" 102 4" 102 * * * * * * 2" 51 2" 511200-500 5" 127 4" 102 * * * * * * 2 1/2" 64 2 1/2" 641200-600 6" 152 4" 102 * * * * * * 3" 76 3" 761200-700 7" 179 4" 127 * * * * * * 3 1/2" 89 3 1/2" 891200-800 8" 203 4" 127 * * * * * * 4" 102 4" 102

Other sizes available

1200 Series Seal – Supplied pre-compressed � Foam seals create a water tight, insulated seal. � Seal material is UV stable and highly resistant to ozone

and chemical degradation. � Capable of handling vertical and horizontal

join movement. � Available in 13 standard colors, custom colors available

upon request. See page 61. � 1200 foam seal comes pre-compressed and includes

peel and stick adhesive sides, makes installation easy. � Available in single, double or triple faced versions. � Good sound attenuation qualities.

2 3/16"(60mm)

1200SERIESW

W

2 3/16"(60mm)

1250SERIES

W

CURTAIN WALL STOREFRONT(BY OTHERS)

W

CURTAIN WALL STOREFRONT(BY OTHERS)

1200 Series(2" (50mm) system shown)

1250 Series(2" (50mm) system shown)

1200 Series(2" (50mm) double-sided system shown)

1250 Series(2" (50mm) double-sided system shown)

W

CURTAIN WALL STOREFRONT(BY OTHERS)

1250 Series(2" (50mm) Custom triple-sided system shown)

2 3/16"(60mm)

1200SERIESW

W

2 3/16"(60mm)

1250SERIES

W

CURTAIN WALL STOREFRONT(BY OTHERS)

W

CURTAIN WALL STOREFRONT(BY OTHERS)

1200 Series(2" (50mm) system shown)

1250 Series(2" (50mm) system shown)

1200 Series(2" (50mm) double-sided system shown)

1250 Series(2" (50mm) double-sided system shown)

W

CURTAIN WALL STOREFRONT(BY OTHERS)

1250 Series(2" (50mm) Custom triple-sided system shown)

(2" (50mm) custom triple-sided system shown)

62

Page 33: MasterFormat™ Division: 7 800.222.5556 | inprocorp.com ...sweets.construction.com/swts_content_files/153383/713886.pdf · Expansion Joint Systems designed to protect appearances,

800.222.5556 | Installation Hotline: 866.ezInpro

inprocorp.com/jointmaster

S80 W18766 Apollo DriveMuskego, WI 53150 USA

800.222.5556 toll-free888.715.8407 toll-free fax262.679.5521 international262.679.5524 international fax 800.437.2698 customer service866.EZINPRO installation hotline ©

2014

InPr

o Co

rpor

atio

n / R

P30

Printed with soy ink on recycled fiber including 10% post-consumer fiber