    Master Meter Proving System

    Quick, easy and accurate meter proving.

    HoneywellEnrafsMasterMetersystemcanbeusedtoprove

    bothPDandturbinemeters.Itisquick,easyandaccurate.

    ByintegratingourMMC-9MeterProverCounterwiththe

    marketleadingpositivedisplacementmeter,Honeywell-Enraf

    hasmanufacturedasystemthatoffersmajoradvantagesover

    similarprovingmethods.Becauseofitsportabledesign,the

    MasterMetersystemcanbeoperatedbyonetechnicianto

    provideinstantprovingresults.

  • 7/27/2019 Master Meter Prvoing

    2/8

    Benefts

    Provingisexecutedasatruckcompartmentisbeingloaded,

    no downtime or delays

    Noneedtoshutdownloadingbaysduringproving

    Aloadrackmetercanbeprovedinamatterofminutes

    Operationallowsforseveralmeterprovingrunsper

    compartment

    No wasteProductisloadedintotransporttruckinsteadofavolumetricprovingcan

    Proventechnology

    Provenreliability

    Compactfootprint

    Onemanoperation

    DesignedtoAPIstandards

    Availableinmanysizesfrom2-10

    10

    4

    Typical Hookup - Master Meter to Rack PD Meter

    6) T emperature Probe

    7) M as ter Meter

    8) GC T-1 Connection Point

    1) P ositive Displaceme nt Meter Assemb ly

    9) GCT-1000 Connec t i on Po in t

    10) Temperature Probe Connec t ion Po in t

    2) Pulse Transmitter

    3) Contro l Valve

    4) Load ing Arm Assembly

    5) Pulse Transmitter

    6

    7

    12

    8

    3

    9

    5

    MASTER METER COMPUTERMMC-9

    Meter Proving Expertise

    Withover30yearsofexperienceintheoilandgasindustry,

    HoneywellEnrafcontinuestodevelopnewsolutionsfortheuid

    measurementindustry.

    Withtheneedfordowntimeofowmeterstobereducedtoa

    minimum,theMasterMetersystemtsperfectlywithtodays

    requirements.

    Typicalapplications:

    Distributionterminalloadrack

    Blendingskids

    Aviationrefueling

    Truckmeters

    Traditional loading

    Simultaneous loading and proving

  • 7/27/2019 Master Meter Prvoing

    3/8

    Features

    4 Meter Brodie

    4BrodieBiRotorPluswithhelicalhardcoatanodized

    aluminiumrotorsanda3pointaccuracytestatfactory.

    Doublecaseconstructionavoidslossofcalibrationdueto

    changesinpressureortemperature

    Newrotorproleprovideshighresistancetoairslugsandentrainedsolids

    Nometal-to-metalcontact

    DualpulseoutputmeetsLevelBpulsesecuritydescribedin

    APImanual,Chapter5.5.4.4

    Explosion-proofamplierhousing

    Singleordualpulseoutput-non-wettedpickoffs

    Reducednumberofpartsreducesmaintenance

    requirements

    Varietyofreadoutinstrumentationavailable

    ClassI,Division1,GroupC&D,NEMA4X,UL,cUL,ATEX,

    EexdIIBT6,NTEP,CRN(Canada)andIndustryCanada

    (Canada),OMILbi-directionalowcapability(Consult

    Factory)

    [email protected]

    Fittedwithventanddrainvalves

    4 Meter Smith

    4SmithmetermodelPrime4withpeakbladesand5point

    accuracytestatfactory

    MeterttedwithventanddrainvalvesInlet/Outlet

    Inletange,150#ANSIxTTMAwithtemperaturewelland

    pressuregauge

    4F500malecouplerwithVitonsealswithdustcap

    2 Honeywell Enra

    NTEPapprovedcustodytransfermeter

    Ruggedstainlesssteeldesign

    RytonovalgearswithTeonseals

    Lowpressuredrop

    SAEsupweldconnections

    Viscocityto300cst.

    Halleffectsensor

    Inlet/Outlet

    Distribution Terminal

    Inletange,150#ANSIxTTMA,withtemperaturewelland

    pressuregauge

    4F500malecouplerwithVitonsealswithdustcap

    4butteryvalvewiththrottlingplatetoobtaindifferingow

    ratesasrequired 4aluminumstyle50swingjointwithVitonseals;oneend

    ASAanged,andoneendTTMAanged

    4x64exiblehosecoupledwithTTMAangettings,

    hydrostatictestedto200psi;withEmcoWheatonJ-451dry

    breakcoupler

    Valve

    Staticgroundingcableandretractablereel(optional)

    Aviation Reueling

    Inletange,150#ANSIwithtemperaturewellandpressure

    gauge

    2.5Todo-45(ISO45)tankunitwithtemperaturewelland

    pressuregauge

    4butteryvalvewiththrottlingplatetoobtaindifferingow

    ratesasrequired

    4aluminumstyle50swingjointwithVitonseals;oneend

    ASAanged,andoneendTTMAanged

    2.5exiblehosecoupledwithTODO-MATIC2coupling

    hydrostatictested

    Dustcaps

    Staticgroundingcableandretractablereel(optional)

    Electronics

    CountmastermodelMMC-9,ElectronicMeterProver

    Counter;12VDCrechargeablebatterypoweredwithbattery

    isolatedandfusedforintrinsicallysafeoperation

    Input setting or master meter actor

    LCDdisplay

    Flowratedisplay

    Temperaturedisplay:ForC;withprobeandcable

    Alarmandstatuslights

    Twoconductorswithgroundextensioncordforrecharging

    theMMC-9batteries

    PTATprobe(proportionaltoabsolutetemperature)with

    connectingcableandplug-injack

    ModelGC-1,P/N09-03005,detachableopticgating

    contactorformountingonRADofmetertobeprovedwith

    25connectingcable

  • 7/27/2019 Master Meter Prvoing

    4/8

    4-wheel Cart

    Fabricatedsteel4-wheelcartwithpinlockedmeterturntable,

    360-degreerotation

    Steelcomponentssandblastedandcoatedwithepoxyprime

    andnish

    2-10rigidcasterand2-10swivelcasterwithswivellock,

    allwithpneumatictires

    Trailer

    Fabricatedsteel2-wheelcartwithJackstand

    Steelcomponentssandblastedandcoatedwithepoxyprime

    andnish

    Hoserack(optional)

    Accessories

    P/N 04-03045

    TMI-1TurbineMeterPre-ampInterfaceModule

    MountedinXPenclosure

    Opticisolationbetweenthepre-ampandtheMMC-9

    Onerequiredperinstalledturbinemeter;customertoadvise

    makeandP/Nofpre-amp

    P/N 04-03050

    TMI-1PClip-onTurbineMeterPre-ampInterfaceModule

    MountedinXPenclosure

    Opticisolationbetweenthepre-ampandtheMMC-9

    Usessmallalligatorclipstomakeconnectiontocustomers

    pre-amp

    Requiresremovalofpre-ampcovertomakeconnections

    whileinuse

    P/N 04-03049

    TMI-1ACLAccuLoadIIorElectronicPresetHighSpeedProver

    OutputInterfaceModule

    MountedinXPenclosure

    OpticisolationbetweenthePresetandtheMMC-9

    IntrinsicallySafeAmphenolconnectorforconnectionto

    MMC-9

    12VDCpoweredfromAccuLoadII

    P/N 04-03020

    MHTS-1MultipleHeadTestStandfortestingF4-S1

    MasterMetersystemelectronicsusedforprovingPDmeters

    Twoconcentricrightangledrives

    HandcrankforperformingvericationfeaturesofMMC-9,

    GC-1,GC-1000andconnectingcables

    P/N 04-03053

    PM4TB-1PrimeMasterMeterelectronicstestboxfortesting

    Prime4MasterMetersystemelectronicsusedforprovingturbine

    metersorsimilarelectronicoutputmeters.

    DesignedtotestcablesandMMC-9

  • 7/27/2019 Master Meter Prvoing

    5/8

    Technical Specifcation

    Flow

    4 Brodie Meter

    Minimumowrate : 70USGallons(245liters)perminute

    Maximumowrate : 700USGallons(2650liters)perminute

    Repeatability : 0.01

    Linearity : 0.075%orbetterover30:1owrangeKFactor : 4ModelB281&B284;96pulses/gallon(25pulses/liter)Note**Note:K-Factorwillvaryfor

    eachmeter

    MaxWorkPressure : 285PSIG

    PressureDrop : 7PSIatmaximumowrate

    4 Smith Meter

    Minimumowrate : 75USGallons(285liters)perminute

    Maximumowrate : 750USGallons(2850liters)perminute

    Repeatability : Lessthanorequalto0.02%.

    Linearity : 0.15%overthenormalowrange.

    PulseResolution : 50pulsespergallon(13pulses/litre).

    MaxWorkPressure : 285PSIG

    PressureDrop :3.2PSIatmaximumowrate

    2 Honeywell Enra

    Minimumowrate : 3USGallons(11liters)perminute

    Maximumowrate : 150USGallons(547liters)perminute

    Repeatability : Lessthanorequalto0.05%.

    Linearity : 0.25%@1CST

    PulseResolution : 384Pulses/Gal(FlowSensor)

    MaxWorkPressure : 400PSIG@100F

    Viscosity : 300CST

    Couplings

    MaxWorkPressure : 150PSIG

    Hose

    MaxWorkPressure : 150PSIG

  • 7/27/2019 Master Meter Prvoing

    6/8

    Electrical (Meter)

    4 Brodie

    Inputs

    Amplier : Dualchannelpreamplier

    SupplyVoltage : 10to30Vdc

    SensorType : Singleordual,non-wetted,reluctance

    Type :SineWave

    Amplitude :40mVpeaktopeakminimumPowered Pulse Output

    Type :SquareWave

    FrequencyRange :0to5kHz

    Amplitude :0to5V

    1kOhmintervalpull-ups,20mAmax.

    Variable Voltage Output

    Type :SquareWave

    FrequencyRange : 0to5kHz.

    Amplitude :0toSupplyVoltage

    1kOhmintervalpull-ups,70mAmax.

    Open Collector Output (Per Channel)

    Type :SquareWave

    FrequencyRange :0to5kHz.

    Max.Voltage :30Vdc

    Max.Current :125mA

    Max.Power :0.5watts

    4 Smith

    Pulse Pick-Up Sensor

    Type : Squarewave/currentsinking

    Input : 6to28Vdc,30mAmax.,20mAtypical

    Powered Pulse Output

    VoltageHigh :(refertomanufacturersspecication)

    VoltageLow :0.8Vdc@20mAsinkcurrent

    DutyCycle :70%on,30%offto30%on,70%off

    Quadrature

    Separationfordualoutputsignalis90+/-40electricaldegrees.

    Pulse Resolution

    50pulsespergallon(13pulsesperlitre)

    2 Honeywell Enra

    Pulse Pick-Up Sensor

    Type : HallEffect

    Input : 4-28Vdc(mayrequireapullupresister)

    Output

    Status : DualPulseQuadrature

    Resolution : 384pulsespergallon

  • 7/27/2019 Master Meter Prvoing

    7/8

    Electrical (MMC-9)

    ACPower : 90to265Volts,48to63hz

    CurrentConsumption : 5watts

    ACPowerInput : FuseprotectedGMC-1/2

    DCPulseInput : Drivingcircuitmustsink10mAtowithin0.8voltsofDCcommon,signalmustrisetoatleas

    4.5ofDCcommon,signalmustrisetoatleast4.5vdc.30vdcopencircuitmaximum.

    Maximumpulseinputfrequency1khz.

    BatteryChargeTime : 8hoursfrom0voltstofullcharge,lessforpartialcharging.BatteryOperationTime : 8hoursminimumwithnewbatteries,lessasbatteriesage.

    Materials

    4 Brodie

    Housing : CarbonSteel

    MeasuringUnit : EndPlates:CastAluminum

    Rotors : CastAluminum,HardAnodized

    RotorShafts : 17-4phStainlessSteel

    RotorBearings : StainlessSteelBallBearings

    O-Rings : VitonStandard(Otherelastomersavailable)

    4 Smith

    Housing&cover : CarbonSteel

    Blades : Polyketone

    Rotor : CastIron

    Cam : HardSurfacedSteel

    Bearings : JournalTypeCastIron

    Seals : Buna-N(standard)orViton

    2 Honeywell Enra

    Case : 316StainlessSteel

    OvalGears : GlasslledRyton

    Posts : 316StainlessSteel

    Seals : Teon

    MMC-9

    Housing : Fiberglassandaluminum

    Hose : ConsultFactory

    Couplings : Highstrengthaluminiumbody,couplingringingunmetal,innerpartsandbayonetange

    highstrengthaluminiumbody,couplingringingunmetal,innerpartsandbayonetangein

    stainlesssteelandaluminium.FKM(Viton),Floursilicone.Othermaterialsonrequest

  • 7/27/2019 Master Meter Prvoing

    8/8

    EN-12-07-US

    June 2012

    2012 Honeywell International Inc.

    For More Inormation

    TolearnmoreaboutHoneywellEnrafs

    solutions,contactyourHoneywellEnraf

    accountmanagerorvisit

    www.honeywellenraf.com.

    Americas

    HoneywellEnrafAmericas,Inc.

    2000NortheldCt.Roswell,GA30076

    USA

    Phone:+17704751900

    Email:[email protected]

    Europe, Middle East and Arica

    HoneywellEnraf

    Delftechpark39

    2628XJDelft

    TheNetherlands

    Phone:+31(0)152701100

    Email:[email protected]

    Asia Pacifc

    HoneywellPteLtd.

    17ChangiBusinessParkCentral1Singapore486073

    Phone:+6563552828

    Email:[email protected]

    Identifcation code

    Pos 1, 2, 3 Product Family

    0 4 - EFTMasterMeterSystemwithMeterCart,MMC9,andconnecting

    Pos 4, 5, 6, 7, 8 Master Meter System

    2 3 0 4 5 MasterMeterCartwithMMC9andconnectingHoses

    9 9 9 9 9 Special

    Pos 9, 10, 11 Size and type o Meter

    F M C 4SmithPrime4MasterMeter

    B R D 4BrodieBi-RotorPlusMasterMeter

    E T H 2HoneywellEthanolCertiedOvalGearMeter

    0 4 - 2 3 0 4 5 E T H Typical identifcation code

    0 4 - Your identifcation code

    Environmental

    4 Brodie

    Temperature : -20to180F(-29to82C)

    Approvals : ClassI,Division1,GroupC&D,NEMA4X,UL,CUL,ATEX,EexdIIBT6NTEP,

    CRN(Canada)andIndustryCanada(Canada),OMIL

    4 Smith

    Temperature : -20to150F(-29to65C)StandardApprovals : UL/CULlistedforuseinClassI,GroupsCandD,Division1and2hazardous

    locationsNEMA4ClassII,GroupsE,F,andG,Division1and2hazardouslocation.

    European/ATEXEExdIIBT6,PTB03ATEX032WeightsandMeasures

    NTEP(US),ISC(Canada),PTB(Germany),GOST(Russia)andothers.

    2 Honeywell Enra

    Temperature : to185F(85C)