Master Meter Proving System
Quick, easy and accurate meter proving.
HoneywellEnrafsMasterMetersystemcanbeusedtoprove
bothPDandturbinemeters.Itisquick,easyandaccurate.
ByintegratingourMMC-9MeterProverCounterwiththe
marketleadingpositivedisplacementmeter,Honeywell-Enraf
hasmanufacturedasystemthatoffersmajoradvantagesover
similarprovingmethods.Becauseofitsportabledesign,the
MasterMetersystemcanbeoperatedbyonetechnicianto
provideinstantprovingresults.
7/27/2019 Master Meter Prvoing
2/8
Benefts
Provingisexecutedasatruckcompartmentisbeingloaded,
no downtime or delays
Noneedtoshutdownloadingbaysduringproving
Aloadrackmetercanbeprovedinamatterofminutes
Operationallowsforseveralmeterprovingrunsper
compartment
No wasteProductisloadedintotransporttruckinsteadofavolumetricprovingcan
Proventechnology
Provenreliability
Compactfootprint
Onemanoperation
DesignedtoAPIstandards
Availableinmanysizesfrom2-10
10
4
Typical Hookup - Master Meter to Rack PD Meter
6) T emperature Probe
7) M as ter Meter
8) GC T-1 Connection Point
1) P ositive Displaceme nt Meter Assemb ly
9) GCT-1000 Connec t i on Po in t
10) Temperature Probe Connec t ion Po in t
2) Pulse Transmitter
3) Contro l Valve
4) Load ing Arm Assembly
5) Pulse Transmitter
6
7
12
8
3
9
5
MASTER METER COMPUTERMMC-9
Meter Proving Expertise
Withover30yearsofexperienceintheoilandgasindustry,
HoneywellEnrafcontinuestodevelopnewsolutionsfortheuid
measurementindustry.
Withtheneedfordowntimeofowmeterstobereducedtoa
minimum,theMasterMetersystemtsperfectlywithtodays
requirements.
Typicalapplications:
Distributionterminalloadrack
Blendingskids
Aviationrefueling
Truckmeters
Traditional loading
Simultaneous loading and proving
7/27/2019 Master Meter Prvoing
3/8
Features
4 Meter Brodie
4BrodieBiRotorPluswithhelicalhardcoatanodized
aluminiumrotorsanda3pointaccuracytestatfactory.
Doublecaseconstructionavoidslossofcalibrationdueto
changesinpressureortemperature
Newrotorproleprovideshighresistancetoairslugsandentrainedsolids
Nometal-to-metalcontact
DualpulseoutputmeetsLevelBpulsesecuritydescribedin
APImanual,Chapter5.5.4.4
Explosion-proofamplierhousing
Singleordualpulseoutput-non-wettedpickoffs
Reducednumberofpartsreducesmaintenance
requirements
Varietyofreadoutinstrumentationavailable
ClassI,Division1,GroupC&D,NEMA4X,UL,cUL,ATEX,
EexdIIBT6,NTEP,CRN(Canada)andIndustryCanada
(Canada),OMILbi-directionalowcapability(Consult
Factory)
Fittedwithventanddrainvalves
4 Meter Smith
4SmithmetermodelPrime4withpeakbladesand5point
accuracytestatfactory
MeterttedwithventanddrainvalvesInlet/Outlet
Inletange,150#ANSIxTTMAwithtemperaturewelland
pressuregauge
4F500malecouplerwithVitonsealswithdustcap
2 Honeywell Enra
NTEPapprovedcustodytransfermeter
Ruggedstainlesssteeldesign
RytonovalgearswithTeonseals
Lowpressuredrop
SAEsupweldconnections
Viscocityto300cst.
Halleffectsensor
Inlet/Outlet
Distribution Terminal
Inletange,150#ANSIxTTMA,withtemperaturewelland
pressuregauge
4F500malecouplerwithVitonsealswithdustcap
4butteryvalvewiththrottlingplatetoobtaindifferingow
ratesasrequired 4aluminumstyle50swingjointwithVitonseals;oneend
ASAanged,andoneendTTMAanged
4x64exiblehosecoupledwithTTMAangettings,
hydrostatictestedto200psi;withEmcoWheatonJ-451dry
breakcoupler
Valve
Staticgroundingcableandretractablereel(optional)
Aviation Reueling
Inletange,150#ANSIwithtemperaturewellandpressure
gauge
2.5Todo-45(ISO45)tankunitwithtemperaturewelland
pressuregauge
4butteryvalvewiththrottlingplatetoobtaindifferingow
ratesasrequired
4aluminumstyle50swingjointwithVitonseals;oneend
ASAanged,andoneendTTMAanged
2.5exiblehosecoupledwithTODO-MATIC2coupling
hydrostatictested
Dustcaps
Staticgroundingcableandretractablereel(optional)
Electronics
CountmastermodelMMC-9,ElectronicMeterProver
Counter;12VDCrechargeablebatterypoweredwithbattery
isolatedandfusedforintrinsicallysafeoperation
Input setting or master meter actor
LCDdisplay
Flowratedisplay
Temperaturedisplay:ForC;withprobeandcable
Alarmandstatuslights
Twoconductorswithgroundextensioncordforrecharging
theMMC-9batteries
PTATprobe(proportionaltoabsolutetemperature)with
connectingcableandplug-injack
ModelGC-1,P/N09-03005,detachableopticgating
contactorformountingonRADofmetertobeprovedwith
25connectingcable
7/27/2019 Master Meter Prvoing
4/8
4-wheel Cart
Fabricatedsteel4-wheelcartwithpinlockedmeterturntable,
360-degreerotation
Steelcomponentssandblastedandcoatedwithepoxyprime
andnish
2-10rigidcasterand2-10swivelcasterwithswivellock,
allwithpneumatictires
Trailer
Fabricatedsteel2-wheelcartwithJackstand
Steelcomponentssandblastedandcoatedwithepoxyprime
andnish
Hoserack(optional)
Accessories
P/N 04-03045
TMI-1TurbineMeterPre-ampInterfaceModule
MountedinXPenclosure
Opticisolationbetweenthepre-ampandtheMMC-9
Onerequiredperinstalledturbinemeter;customertoadvise
makeandP/Nofpre-amp
P/N 04-03050
TMI-1PClip-onTurbineMeterPre-ampInterfaceModule
MountedinXPenclosure
Opticisolationbetweenthepre-ampandtheMMC-9
Usessmallalligatorclipstomakeconnectiontocustomers
pre-amp
Requiresremovalofpre-ampcovertomakeconnections
whileinuse
P/N 04-03049
TMI-1ACLAccuLoadIIorElectronicPresetHighSpeedProver
OutputInterfaceModule
MountedinXPenclosure
OpticisolationbetweenthePresetandtheMMC-9
IntrinsicallySafeAmphenolconnectorforconnectionto
MMC-9
12VDCpoweredfromAccuLoadII
P/N 04-03020
MHTS-1MultipleHeadTestStandfortestingF4-S1
MasterMetersystemelectronicsusedforprovingPDmeters
Twoconcentricrightangledrives
HandcrankforperformingvericationfeaturesofMMC-9,
GC-1,GC-1000andconnectingcables
P/N 04-03053
PM4TB-1PrimeMasterMeterelectronicstestboxfortesting
Prime4MasterMetersystemelectronicsusedforprovingturbine
metersorsimilarelectronicoutputmeters.
DesignedtotestcablesandMMC-9
7/27/2019 Master Meter Prvoing
5/8
Technical Specifcation
Flow
4 Brodie Meter
Minimumowrate : 70USGallons(245liters)perminute
Maximumowrate : 700USGallons(2650liters)perminute
Repeatability : 0.01
Linearity : 0.075%orbetterover30:1owrangeKFactor : 4ModelB281&B284;96pulses/gallon(25pulses/liter)Note**Note:K-Factorwillvaryfor
eachmeter
MaxWorkPressure : 285PSIG
PressureDrop : 7PSIatmaximumowrate
4 Smith Meter
Minimumowrate : 75USGallons(285liters)perminute
Maximumowrate : 750USGallons(2850liters)perminute
Repeatability : Lessthanorequalto0.02%.
Linearity : 0.15%overthenormalowrange.
PulseResolution : 50pulsespergallon(13pulses/litre).
MaxWorkPressure : 285PSIG
PressureDrop :3.2PSIatmaximumowrate
2 Honeywell Enra
Minimumowrate : 3USGallons(11liters)perminute
Maximumowrate : 150USGallons(547liters)perminute
Repeatability : Lessthanorequalto0.05%.
Linearity : 0.25%@1CST
PulseResolution : 384Pulses/Gal(FlowSensor)
MaxWorkPressure : 400PSIG@100F
Viscosity : 300CST
Couplings
MaxWorkPressure : 150PSIG
Hose
MaxWorkPressure : 150PSIG
7/27/2019 Master Meter Prvoing
6/8
Electrical (Meter)
4 Brodie
Inputs
Amplier : Dualchannelpreamplier
SupplyVoltage : 10to30Vdc
SensorType : Singleordual,non-wetted,reluctance
Type :SineWave
Amplitude :40mVpeaktopeakminimumPowered Pulse Output
Type :SquareWave
FrequencyRange :0to5kHz
Amplitude :0to5V
1kOhmintervalpull-ups,20mAmax.
Variable Voltage Output
Type :SquareWave
FrequencyRange : 0to5kHz.
Amplitude :0toSupplyVoltage
1kOhmintervalpull-ups,70mAmax.
Open Collector Output (Per Channel)
Type :SquareWave
FrequencyRange :0to5kHz.
Max.Voltage :30Vdc
Max.Current :125mA
Max.Power :0.5watts
4 Smith
Pulse Pick-Up Sensor
Type : Squarewave/currentsinking
Input : 6to28Vdc,30mAmax.,20mAtypical
Powered Pulse Output
VoltageHigh :(refertomanufacturersspecication)
VoltageLow :0.8Vdc@20mAsinkcurrent
DutyCycle :70%on,30%offto30%on,70%off
Quadrature
Separationfordualoutputsignalis90+/-40electricaldegrees.
Pulse Resolution
50pulsespergallon(13pulsesperlitre)
2 Honeywell Enra
Pulse Pick-Up Sensor
Type : HallEffect
Input : 4-28Vdc(mayrequireapullupresister)
Output
Status : DualPulseQuadrature
Resolution : 384pulsespergallon
7/27/2019 Master Meter Prvoing
7/8
Electrical (MMC-9)
ACPower : 90to265Volts,48to63hz
CurrentConsumption : 5watts
ACPowerInput : FuseprotectedGMC-1/2
DCPulseInput : Drivingcircuitmustsink10mAtowithin0.8voltsofDCcommon,signalmustrisetoatleas
4.5ofDCcommon,signalmustrisetoatleast4.5vdc.30vdcopencircuitmaximum.
Maximumpulseinputfrequency1khz.
BatteryChargeTime : 8hoursfrom0voltstofullcharge,lessforpartialcharging.BatteryOperationTime : 8hoursminimumwithnewbatteries,lessasbatteriesage.
Materials
4 Brodie
Housing : CarbonSteel
MeasuringUnit : EndPlates:CastAluminum
Rotors : CastAluminum,HardAnodized
RotorShafts : 17-4phStainlessSteel
RotorBearings : StainlessSteelBallBearings
O-Rings : VitonStandard(Otherelastomersavailable)
4 Smith
Housing&cover : CarbonSteel
Blades : Polyketone
Rotor : CastIron
Cam : HardSurfacedSteel
Bearings : JournalTypeCastIron
Seals : Buna-N(standard)orViton
2 Honeywell Enra
Case : 316StainlessSteel
OvalGears : GlasslledRyton
Posts : 316StainlessSteel
Seals : Teon
MMC-9
Housing : Fiberglassandaluminum
Hose : ConsultFactory
Couplings : Highstrengthaluminiumbody,couplingringingunmetal,innerpartsandbayonetange
highstrengthaluminiumbody,couplingringingunmetal,innerpartsandbayonetangein
stainlesssteelandaluminium.FKM(Viton),Floursilicone.Othermaterialsonrequest
7/27/2019 Master Meter Prvoing
8/8
EN-12-07-US
June 2012
2012 Honeywell International Inc.
For More Inormation
TolearnmoreaboutHoneywellEnrafs
solutions,contactyourHoneywellEnraf
accountmanagerorvisit
www.honeywellenraf.com.
Americas
HoneywellEnrafAmericas,Inc.
2000NortheldCt.Roswell,GA30076
USA
Phone:+17704751900
Email:[email protected]
Europe, Middle East and Arica
HoneywellEnraf
Delftechpark39
2628XJDelft
TheNetherlands
Phone:+31(0)152701100
Email:[email protected]
Asia Pacifc
HoneywellPteLtd.
17ChangiBusinessParkCentral1Singapore486073
Phone:+6563552828
Email:[email protected]
Identifcation code
Pos 1, 2, 3 Product Family
0 4 - EFTMasterMeterSystemwithMeterCart,MMC9,andconnecting
Pos 4, 5, 6, 7, 8 Master Meter System
2 3 0 4 5 MasterMeterCartwithMMC9andconnectingHoses
9 9 9 9 9 Special
Pos 9, 10, 11 Size and type o Meter
F M C 4SmithPrime4MasterMeter
B R D 4BrodieBi-RotorPlusMasterMeter
E T H 2HoneywellEthanolCertiedOvalGearMeter
0 4 - 2 3 0 4 5 E T H Typical identifcation code
0 4 - Your identifcation code
Environmental
4 Brodie
Temperature : -20to180F(-29to82C)
Approvals : ClassI,Division1,GroupC&D,NEMA4X,UL,CUL,ATEX,EexdIIBT6NTEP,
CRN(Canada)andIndustryCanada(Canada),OMIL
4 Smith
Temperature : -20to150F(-29to65C)StandardApprovals : UL/CULlistedforuseinClassI,GroupsCandD,Division1and2hazardous
locationsNEMA4ClassII,GroupsE,F,andG,Division1and2hazardouslocation.
European/ATEXEExdIIBT6,PTB03ATEX032WeightsandMeasures
NTEP(US),ISC(Canada),PTB(Germany),GOST(Russia)andothers.
2 Honeywell Enra
Temperature : to185F(85C)