Rope sensor for elevators load control Serie: SW-OMEGA Ø 8...16 mm Manual OF Installation Dinacell Electrónica, s.l. Poligono Industrial Santa Ana C/ Torno, 8 - 28529 Rivas Vacia-Madrid - Tel. 913 001 435 - Fax: 913 001 645 E-mail: [email protected] - http://www.dinacell.com SENSOR MESH EXC.+ +IN EXC.- -IN AL-S AL-C AUX. Power supply Exit of relay Overload Complete Cable screen Black White Green Red SERIES VK ~ 4 AL-C 1 3 2 6 5 AL-S 220 MENU VK-2T SW - D Load Cells 1 2 Step 5. Connection of the sensor (SW-OMEGA) to unit control (VK-OMEGA) Connection of the sensor (SW-Omega). The SW-Omega has a special wire con- nection made by terminal pins. Depen- ding the number of ropes of installation will be considered as a group of sensors to be united. Once the sensor is already connected to the unit control VK-Omega, you could start to calibrate the unit (Please look at the manual instruction of the unit VK for the calibration process).

Manual SW_Omega (ing)

Embed Size (px)

DESCRIPTION

Manual del equipo SW_Omega en formato pdf (idioma:inglés)

Citation preview

Page 1: Manual SW_Omega (ing)

Rope sensor forelevators load controlSerie: SW-OMEGA

Ø 8...16 mm

Manual OF InstallationDinacell Electrónica, s.l.Poligono Industrial Santa AnaC/ Torno, 8 - 28529 Rivas Vacia-Madrid - Tel. 913 001 435 - Fax: 913 001 645E-mail: [email protected] - http://www.dinacell.com

SENSOR

ME

SH

EX

C.+

+IN

EX

C.-

-IN

AL-SAL-C

AUX.

Power supplyExit of relay

OverloadComplete

Cable screen

Black

WhiteGreen

Red

SERIES VK

~4AL-C

1 3

2

6

5

AL-S220

MENU

VK-2T

SW - DLoad Cells

1 2

Step 5. Connection of the sensor (SW-OMEGA) to unit control (VK-OMEGA)

Connection of the sensor (SW-Omega).The SW-Omega has a special wire con-nection made by terminal pins. Depen-ding the number of ropes of installationwill be considered as a group of sensors to be united.

Once the sensor is already connected to the unit control VK-Omega, you could start tocalibrate the unit (Please look at the manual instruction of the unit VK for the calibrationprocess).

Page 2: Manual SW_Omega (ing)

Manual of Installation Sensor SW-OMEGA

Models Diameter Range of load Nº of group of the cable (standard) of sensors

SW-OMEGA1 Ø 8, 9, 10 600 kg/cableSW-OMEGA2 Ø 11, 12, 13 800 kg/cable 2, 3, 4, 5, 6, 7, 8SW-OMEGA3 Ø 14, 15 16 1.600 kg/cable

1. INTRODUCTION

A load weighing device model SW-OMEGA, groups of active load cell was develo-ped to measure the weight on elevators and freight elevators, as well to control the ten-sion in each one of the cables in an independent way.

In this new sensor whose placement is carried out individually in each cable, that youwill find more advantages on the installation.

Advantages of the sensor SW-OMEGA- Installation and maintenance at low cost.- Fast and easy to install( Installation takes only a few minutes,no need to waste

time to screws).- Flexibility to place in an convenient position.

2. MODELS OF THE SERIE SW-OMEGA

Contents:a) Sensor SW-OMEGAb) 3 pins of support (2 fix pins & 1 loose pin)c) Installation tools

3. INSTALLATION OF THE SENSOR SW-OMEGA

In each cable must place a sensor.

The sensor has 2 fixed pins on it and once it is already placeon the cable, the last pin must be introduce.

Step 1

You could place the sensor on the tools or putdirectly the sensor on the cable and hold it by thetool.

Step 2

Now fit the sensor on the cable and start to bend.

Step 3

Then once the hole of the sensor is already atsight, introduce the third pin on the hole.

Step 4

Finally upon introducing the last pin, the sensor is now readyto function.

Same procedure must be repeated to install the other sensor.

Note: The Sensor could placed in the position that youconsiders more suitable. You have to avoid the crash ofone against the other.