24
Version of the manual: 3.1 en www.go-sys.de Manual BlueBox Control Center - SCADA-

Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en . Manual . BlueBox Control Center - SCADA-

Embed Size (px)

Citation preview

Page 1: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

Version of the manual: 3.1 en

www.go-sys.de

Manual BlueBox Control Center

- SCADA-

Page 2: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 2 / 24 www.go-sys.de [email protected]

Copyright This manual contains information which is the intellectual property of GO Systemelektronik GmbH. The user is obliged to use this information exclusively to run the instrument. It is not permitted to pass this information to third parties. Reproducing, copying, editing or extracting the manual contents is only allowed with the express permission of GO Systemelektronik GmbH. Changes GO Systemelektronik GmbH retains the right to modify the contents of the manual without prior notice. Liability exclusion GO Systemelektronik GmbH takes no responsibility for correct system operation under all possible operating conditions. It is not possible to guarantee that the software will function completely without error under all possible circumstances. GO Systemelektronik GmbH cannot therefore accept liability for direct or indirect damage resulting from system operation or the contents of this manual. Product observance Within the scope of our obligation for product observance GO Systemelektronik GmbH will endeavour to warn third parties about all identified dangers which could arise from the interaction between hardware and soft-ware and from the use of other components. Effective product observance is only possible with adequate information from the end user about the planned field of application and the hardware and software used. If the conditions of use change or if the hardware or software are changed, due to the complex relationships between hardware and software it is no longer possible to describe all possible dangers and their effects on the total system, in particular on our system. This manual does not describe every possible property and combination of the system. For further information, please contact GO Systemelektronik GmbH. Manufacturer’s declaration When installing the system it is necessary to ensure correct electrical connection, protection against moisture and foreign bodies and excessive condensation, and system heating which can arise from both correct and incorrect use. It is the responsibility of the installer to ensure that the correct installation conditions are pro-vided.

Creation date: 27.5.2015 Described firmware version: 3.7.0.0 (extended to: 3.7.3.0)

Version of the manual: 3.1 en Article number of the manual: DOC 420 6203-E-3.1-BDA

Manual_BlueBox_Control_Center_V3p1_en.pdf

© GO Systemelektronik GmbH Faluner Weg 1 D- 24109 Kiel Germany Tel.: 0431/58080-0 Fax: 0431/58080-11 http://www.go-sys.de [email protected]

Page 3: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 3 / 24 www.go-sys.de [email protected]

Table of content 1 Overview ................................................................................................................................................................................... 4 2 Installation ................................................................................................................................................................................ 4 3 Program structure .................................................................................................................................................................... 5 4 Keyboard and mouse operation .............................................................................................................................................. 6 5 Menu operation ........................................................................................................................................................................ 7

5.1 Load file ............................................................................................................................................................................. 75.2 Save file .............................................................................................................................................................................. 75.3 Program exit ...................................................................................................................................................................... 75.4 System settings ................................................................................................................................................................. 75.5 Setup add sensor/actuator ............................................................................................................................................... 85.6 Connect/Disconnect .......................................................................................................................................................... 85.7 About .................................................................................................................................................................................. 95.8 Status ................................................................................................................................................................................. 9

6 Visualization elements sensors ............................................................................................................................................. 10

6.1 Example control sensor S8 .............................................................................................................................................. 126.2 Common sensor settings ................................................................................................................................................ 13

6.2.1 Area Alarm ................................................................................................................................................................ 136.2.2 Cursor ........................................................................................................................................................................ 136.2.3 Height ....................................................................................................................................................................... 136.2.4 Hint ............................................................................................................................................................................ 146.2.5 Left ............................................................................................................................................................................ 146.2.6 Area Sensor ............................................................................................................................................................... 146.2.7 Show Hint ................................................................................................................................................................. 146.2.8 Area Top | Value | Width ........................................................................................................................................... 15

6.3 Option AutoSize ............................................................................................................................................................... 156.4 Area Signal Settings ........................................................................................................................................................ 156.5 Area Sector Settings ........................................................................................................................................................ 166.6 Graphic assignment visualization element S16 ............................................................................................................ 17

7 Visualization elements actors ............................................................................................................................................... 18

7.1 Example control actor A8 ................................................................................................................................................ 197.2 Common sensor settings ................................................................................................................................................ 20

7.2.1 Area Actuator ........................................................................................................................................................... 207.2.2 Cursor ........................................................................................................................................................................ 207.2.3 Enabled ..................................................................................................................................................................... 207.2.4 Height ....................................................................................................................................................................... 207.2.5 Hint ............................................................................................................................................................................ 207.2.6 Left ............................................................................................................................................................................ 217.2.7 Show Hint ................................................................................................................................................................. 217.2.8 Top ............................................................................................................................................................................ 217.2.9 Width ......................................................................................................................................................................... 21

7.3 Value ................................................................................................................................................................................ 21 8 Visualisation element Label .................................................................................................................................................. 22 9 Visualisation element Mute ................................................................................................................................................... 22 10 Status signals of the visualisation elements ..................................................................................................................... 22 Appendix - Visualization examples .......................................................................................................................................... 23

Page 4: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 4 / 24 www.go-sys.de [email protected]

1 Overview BlueBox Control Center Software is a SCADA solution for the BlueBox system for process visualization in real time. Properties:

• extensive graphical representation of measured values and states of actuators • program call-up • definition of alarm values associated with the activation of programs and alerts • value transfer to a BlueBox • setting of actuators • multiple windows links

2 Installation The program is installed simultaneously at the BlueBox PC Software and BlueMon PC Software installation. If you have not installed the BlueBox Control Center Software, install the BlueBox/BlueMon PC Software again. But this time with checked box next to "Control Center Visualisation".

see manual BlueBox PC Software/ Appendix B - Installation of the BlueBox PC Software

Page 5: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 5 / 24 www.go-sys.de [email protected]

3 Program structure The program creates .cc1-files. These files can have a integrated background image in the .jpg-format (see 3.4 System settings).

With intact connection with at least one sensor, here the time of the last transfer is shown.

On this window surface visualization elements (representations) of sensors and actuators can be positioned . These are assigned to a sensor, an actuator or BlueBox variable. In addition, programs can be executed via a visualization element, so you can, for example, open other cc1.-files from a .cc1-file and build nested multi window visualizations. Each visualization element has a separate window for the specific settings, called control window.

example control window: The menu language is set in the BlueBox SQL program.

see manual BlueBox PC Software/ 3.1 Language selection

Page 6: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 6 / 24 www.go-sys.de [email protected]

4 Keyboard and mouse operation

• F4: Selection previous visualization element The previous visualization element is selected. The order is determined by the position of the ele-ments in the visualization window from top left to bottom right. Note that the reference point is the upper left corner of the visualization element. The corresponding control window appears .

• F5: Selection next visualization element The next visualization element is selected. The order is determined by the position of the element in the visualization window from top left to bottom right. Note that the reference point is the upper left corner of the visualization element . The corresponding Control window appears .

• F 12: Clear selection Deletes the selected visualization element. Note that the deletion can not be undone1.

• Ctrl + C Copies the selected visualization element to the clipboard.

• Alt + V Adds a clipboard copied visualization element into the window, all settings of the copied visualization element are taken with, except the sensor ID2.

• Ctrl+V Adds the settings of a clipboard copied visualization element into a selected element, all settings of the copied visualization element are taken with, except the sensor ID 2.

• Arrow keys Selected visualization element will be moved one pixel by pressing an arrow key.

• Left Mouse Button A selected visualization element can be positioned and scaled by holding down the left mouse button on the selection frame. Double-clicking with the left mouse button on the selection frame deselects . Visualization elements can be pushed out of their selection window into the window box with the left mouse button.

1 for example with Ctrl+Z 2 varies depending on the sensor/actuator type

Page 7: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 7 / 24 www.go-sys.de [email protected]

5 Menu operation

5.1 Load file Loading a .cc1-file

5.2 Save file Saving a .cc1-file After the storage a grey circle and the file name appears in left of the title bar. Depending on the state the circle changes its color (see 5.6 Connect/Disconnect).

5.3 Program exit Exit the program Note that unsaved changes will be discarded without con-fimation.

5.4 System settings After the first call-up of the system settings a password must be entered. If you were given no other password, the password is "gosys". Background Picture: Input of the file path of the back-ground image (.jpg-file). Update interval: Input of the value transmission update interval in seconds

Page 8: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 8 / 24 www.go-sys.de [email protected]

5.5 Setup add sensor/actuator Opens the window for the selection of visualization ele-ments for sensors and actuators∗. Furthermore you can also define three basic settings here: BlueBox: selection of a BlueBox Sensor: selection of a sensor of the selected BlueBox Variable: selection of a variable of the selected BlueBox An element is pushed with the left mouse button into the window box.

5.6 Connect/Disconnect Connects or disconnects the connection of sensors and actuators. Depending on the state of the connection the circle in left of the title bar changes its colour. grey circle ⇒ connection is disconnected red circle ⇒ connection is faulty green circle ⇒ connection is established

∗ and a label and a mute button

Page 9: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 9 / 24 www.go-sys.de [email protected]

5.7 About Opens a window with program information.

5.8 Status ▶ BlueBox name or IP address [Active/n]

Allocated sensors and actuators are connected and active, n = number of all sensors/actuators of the BlueBox.

▶ BlueBox name or IP address [Closed] Allocated BlueBox is not connected.

▶ Sensor ID Sensor not found Allocated sensor is not connected.

GO-Systemelektronik [Active/28]

Page 10: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 10 / 24 www.go-sys.de [email protected]

6 Visualization elements sensors

Nr. Symbol Function

S1 simple text display, colours assignable

S2

text display with description

S3

Text display and a horizontal bar display

S4

text display, vertical bar display and description

S5

text display, horizontal bar display and description

S6

text display, vertical bar display with scale, drag indicator for maximum value and description

S7

text display (tank level gauge) and vertical 3-colour gauge display

S8

text display, vertical 3-colour bar display with scale, drag indicator for maximum/minimum value and description

Page 11: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 11 / 24 www.go-sys.de [email protected]

S9

horizontal 3-colour bar display with scale, drag indicator for maximum value and description

S10

120° arc 3-colour bar display with scale, drag indicator for maxi-mum value and description

S11

180° arc 3-colour bar display with scale, drag indicator for maxi-mum value and description

S12

270° arc 3-colour bar display with scale, drag indicator for maxi-mum value and description

S13

x,y time display

S14 2-colour on/off display and description

S15

2-colour on/off display

S16

on/off display with selectable graphics, 6.6 Graphic assignment visualization element S16

S17

x,y time display

S18

text display, time and description

Page 12: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 12 / 24 www.go-sys.de [email protected]

6.1 Example control sensor S8

As can be seen, the setup properties can be extensive. However sensor visualization ele-ments have areas that are common to all. Some of these areas are highlighted here.

1

5

6

7

8

2

3 4

Page 13: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 13 / 24 www.go-sys.de [email protected]

6.2 Common sensor settings 6.2.1 Area Alarm

- Active activation/deactivation of the automatic alarm (true = enabled)

- AlarmResetOnClick from program version 3.7.3.0

true = The alarm will only reset by clicking on the visualization element. false = The alarm will only reset by exceeding or falling short of the alarm values.

- Execute Input of the file path of a program, automatically started when an alarm is trig-gered.

- MaxValue When this value is exceeded, the alarm is triggered.

- MinValue When this value is underrunned, the alarm is triggered.

- MuteOnClick

from program version 3.7.3.0 true = click on the visualization element suppresses the alarm sound, click again and the subpression is disabled. ???

- Popup true = The corresponding window is displayed in the foreground.

- Soundfile File path (absolute or relative to control.exe) of a sound file, this file is played when an alarm is triggered. Precondition: Sound format is recognized by the operating system.

- SoundLoop true = The above enterd sound file is played in a continuous loop when an alarm is triggered.

6.2.2 Cursor

Selection rollover cursor shape no Cursor: S17 6.2.3 Height

Setting of the height of a visualization element in pixels

Page 14: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 14 / 24 www.go-sys.de [email protected]

6.2.4 Hint

Text hint for the rollover, see [7] ShowHint, detailed settings in area HintOptions, here not described 6.2.5 Left

Setting of the horizontal position of the visualization element in pixels from the left edge of the window. Refers to the upper left corner of the visualization element. 6.2.6 Area Sensor

- Auto Name Activation/deactivation of the automatic name mapping (true = activated) Activated: The in AMS assigned sensor name∗ is shown (except S1).

- Auto Unit Activation/deactivation of the automatic value unit mapping (true = activated) Activated: The in AMS assigned sensor name∗ is shown (except S1).

- BlueBoxID Serial number of the BlueBox

- Execute Input of the file path of a program, the program is started by double-clicking the visuali-zation element.

- Multiplier Multiplies the sensor value by the entered number (e.g. for unit conversions).

- SensorID SensorID∗ of the sensor

- Variable Causes that the visualization element is not assigned to a sensor, but to a variable of the selected BlueBox.

6.2.7 Show Hint

Activates or deactivates the rollover text.

∗ see Manual BlueBox PC Software/5.4.1 Sensor settings (Sensor setup)

Page 15: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 15 / 24 www.go-sys.de [email protected]

6.2.8 Area Top | Value | Width

- Top Setting of the vertical position of the visualization element in pixels from the upper edge of the window. Refers to the upper left corner of the visualization element.

- Value Manual input of the displayed value of the visualization element for test purposes, is overwritten by real values.

- Width Setting of the width of a visualization element in pixels

no Value: S14 und S17 two Values: S13

6.3 Option AutoSize Sensors S1/S2/S4-S6/S8 - S12/S16

If this option is activated, the corresponding element will be displayed as small as possible.

6.4 Area Signal Settings Sensors S2 - S12 The settings in the Settings area determines the type of numerical and graphical representation of values.

- DigitalFrom Bottom digital value, depending on the sensor

- DigitalTo Top digital value, depending on the sensor

- Name1 Displayed name Precondition: AutoName = false (siehe 6.2.6 Area Sensor)

- ValueFormat Numerical representation of the value, here of one to three integer places

- ValuFrom Lowest graphic displayable value, at 0 level with the height 0

- ValueTo Highest graphic displayable value

- ValueUnit Displayed value unit Precondition: AutoUnit=false (see 6.2.6 Area Sensor)

Page 16: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 16 / 24 www.go-sys.de [email protected]

6.5 Area Sector Settings Sensors S2 - S11 With this settings three value ranges can be determined. This value ranges can be assigned to display colours. Example: • Signal range settings as previous page • Values range from 0 to 100, • converted to the digital value range 0 to 1000 • Value ≥ 0 and ≤ 10 color yellow • Value> 10 and ≤ 8 color green • Value> 80 and ≤ 100 color red Precondition aktivierte Option opUseSectorCol

- Sector 1Color Display colour Sector 1

- Sector1From Start Sector 1

- Sector1To End Sector 1

- Sector 2Color Display colour Sector 2

- Sector2From Start Sector 2

- Sector2To End Sector 2

- Sector 3Color Display colour Sector 3

- Secto3From Start Sector 3

- Sector3To End Sector 3

Page 17: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 17 / 24 www.go-sys.de [email protected]

6.6 Graphic assignment visualization element S16 Three graphics files can be assigned to visualization element S16:

• Picture ⇒ I no function • PictureOff ⇒ Image at Value = 0 • PictureOn ⇒ Image at Value = 1

Clicking the button opens another window.

Opens a window to select a graphics file (*.bmp; *.ico; *.emf; *.wmf; *.jpg).

Opens a window for storing a selected graphic file.

Deletes the selection.

Transfers the selection.

Closes the window without saving.

Listing of selected graphic by clicking <Load>

Page 18: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 18 / 24 www.go-sys.de [email protected]

7 Visualization elements actors

Nr. Symbol Function

A1

"Dip-switch" with two states

A2

„Slide switch“with two states

A3

„Press switch“with two states

A4 „Press switch“with two states

A5

„Press switch“with two states

A6

Value input via a vertical slider with scale

A7

Value input via a horizontal slider with scale

A8

Value input via a control dial with scale

A9 Values input via a colour-assignable input field

Page 19: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 19 / 24 www.go-sys.de [email protected]

7.1 Example control actor A8

As can be seen, the setup properties can be extensive. However actuator visualization ele-ments have areas that are common to all. Some of these areas are highlighted here.

1

5 6

7

8

2

3

4

9

Page 20: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 20 / 24 www.go-sys.de [email protected]

7.2 Common sensor settings 7.2.1 Area Actuator

- BlueBoxID Serial number of a BlueBox

- Password Setting a password, is requested when operation of the element.

- Variable Input of a variable name, the corresponding variable is changed in operation. see also: 5.5 Setup add sensor/actuator, variable drop-down menu Precondition: The network password needs to be entered in the BlueBox the RAS setup. see Manual BlueBox PC Software 3.2.3 RAS setup

7.2.2 Cursor

Selection rollover cursor shape 7.2.3 Enabled

Enables or disables the functionality of the actuator. 7.2.4 Height

Setting of the height of a visualization element in pixels 7.2.5 Hint

Rollover tex, see [7] ShowHint

Page 21: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 21 / 24 www.go-sys.de [email protected]

7.2.6 Left

Setting of the horizontal position of the visualization element in pixels from the left edge of the window. Refers to the upper left corner of the visualization element. 7.2.7 Show Hint

Activates or deactivates the rollover text. 7.2.8 Top

Setting of the vertical position of the visualization element in pixels from the upper edge of the window. Refers to the upper left corner of the visualization element. 7.2.9 Width

Setting of the width of a visualization element in pixels

7.3 Value Actuators A5 - A9

Manual input of a value

Page 22: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 22 / 24 www.go-sys.de [email protected]

8 Visualisation element Label

Nr. Symbol Function

D1 coloured text field

The Label element is used to label a visualization. The marked lines with an arrow are described in 7.2 9 Visualisation element Mute

Nr. Symbol Function

D2

Click on the visualization element mutes all curent alarm sounds.

10 Status signals of the visualisation elements The hands of the sensors S8 to S12 flash if there is no connection with the respective assigned sensor.

from program version 3.7.3.0

GO Systemelektronik

Page 23: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 23 / 24 www.go-sys.de [email protected]

Appendix - Visualization examples

Monitoring of a fish farm, control of emergency gas flow

Monitoring and controlling of a fermentation chain of a biogas plant

Page 24: Manual BlueBox Control Center - SCADA- - GO-Sys€¦ · Version of the manual: 3.1 en  . Manual . BlueBox Control Center - SCADA-

BlueBox Control Center - SCADA-

GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49(0)431-58080-0 Fax: -58080-11 Page 24 / 24 www.go-sys.de [email protected]

Monitoring and controlling a research platform in the North Sea, calling-up Webcams

Operation mode controlling of a large aquarium Displaying a multi-parameter measurement

in a sewage treatment plant