MAINTENANCE APPROACH PREPARED BY: ASYUARAA NAIM TING NOR ASHIDA ANTS RESOURCES SDN. BHD

Maintenance Gas

Embed Size (px)

DESCRIPTION

this is maintenance of gas

Citation preview

MAINTENANCE APPROACH

MAINTENANCE APPROACH

prepared by:asyuaraanaimting nor ashidaANTS RESOURCES SDN. BHDEquipment Maintenance CategoryMaintenance Strategy & ApproachRun to fail - breakdownCondition based - predictiveTime based - preventive Jetty, Crude & Finished ProductPipeline systemRun to fail - pressure relief valveCondition based - internal & external thickness Time based - coating

PlatformRun to fail - safety precautions Condition based - structure & mechanical partsTime based - paintingStorage TanksStorage tankRun to fail - fitting, gauge, valvesCondition based - tank structureTime based - coating, foundation, jacking

Pumping StationsPipingRun to fail - pipe, gasket leakCondition based - thickness checkTime based - paintingMotorRun to fail - rotor / stator rewindingCondition based - bearingTime based - greasingPumpRun to fail - mechanical sealCondition based - bearingTime based oil change

Heating Furnace SystemAir systemRun to fail air filterCondition based - blowerHeat exchanging unitRun to fail - thermostatCondition based thickness & structural checkRadiant tubeCondition based thickness checkProcess UnitBoiler condition basedHot spotsDistillation Column time basedClean the column upon turnaroundCracking Unit time basedFresh catalystPipelines condition based

Steam Generator SystemFuel oil tank condition basedIf any leakagePump time based

Burner condition based

Atomizer condition based Sprayer plate

Pump (pressure affects oil quality) High; bigger opening orificeLow; smaller opening orifice

9Residual Discharge SystemGravity Oil/Water SeparatorTanks condition basedleakagesPumps time basedBaffles condition based

LaboratoryGas & air supply condition basedrestockTesting analyzers time basedcalibrateTesting materials run to failexpiredCOMPRESSED AIR SYSTEMMotorUse condition based maintenance Spare partsUse time based maintenanceAir/oil coolerUse run to fail

FIRE FIGHTING SYSTEMFire ExtinguishersUse time based maintenanceInspect at least once a month (more often in severe environments)Maintain at least once a year

Fire Sprinkler SystemSprinkler MaintenanceUse condition based maintenanceFire Alarm Maintenance- Use run to fail

CONTROL CENTREMCC equipmentUse condition based maintenanceFire fighting systemUse condition based maintenanceValvesUse condition based maintenanceSensorsuse condition based maintenance

OFFICE BUILDINGGenerator setUse time based maintenanceTransformerUse condition based maintenanceLight, power plug, wiring, etcUse run to fail