20
flowmeters for open channels & partfilled pipes n Velocity Transmitter n AV-Flow Transmitter n Compact Fixed AV-FlowMeter n Premier Fixed AV-FlowMeter n Portable AV-FlowMeter MAINSTREAM MEASUREMENTS PRODUCT GUIDE

MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

flowmeters for open channels & partfilled pipes

n Velocity Transmitter

n AV-Flow Transmitter

n Compact Fixed AV-FlowMeter

n Premier Fixed AV-FlowMeter

n Portable AV-FlowMeter

MAINSTREAM MEASUREMENTS

PRODUCT GUIDE

Page 2: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

measurement principle

Mainstream uses the area-velocity method to give acontinuous or time sample measurement of fluid flow.Mainstream uses a streamlined probe that operatesimmersed in the flowing liquid. The velocity probetransmits ultrasound into the liquid to create a zone ofinspection. Bubbles and solid particles carried throughthis zone by the flow, even when present in only minutequantities, reflect ultrasound back to the probe.

The received ultrasound signal is processed to produce ahistogram of the flow velocities. Analysing this histogramgives the mean flow velocity. Only signals containingverified velocity information are used, thereby ensuringmeasurement integrity.

Liquid level is measured by a submerged pressuretransmitter or ultrasonic sensor. The flow crosssectionalarea is deduced from the liquid level measurementand the stored description of the channel or pipe crosssection. The flow rate is the flow velocity multiplied bythe flow crosssectional area.

LEADERS IN OPEN CHANNELFLOW MEASUREMENT

A key feature of ourapproach to sensor designis recognizing the need forbuilt-in sensor integritymonitoring or self-diagnostics

about mainstream

We are leaders in open channel flow measurement, usingultrasonic technology. The Mainstream flowmeter productrange was borne out of the R & D company CromaDevelopments, a company founded in 1986. Croma wasdeveloped as a vehicle for transferring academic researchresults into commercial applications. The company isnow concerned with research, development and designof instrumentation with a heavy emphasis on embeddedmicroprocessors.

expertise

A key feature of our approach to sensor design isrecognizing the need for builtin sensor integritymonitoring or selfdiagnostics. Areas of particularexpertise are: low-power electronics; signalprocessing; novel algorithms andultrasonics.

The Mainstream product range is noted for highperformance, reliability and above all else is costcompetitive. Mainstream flowmeters feature a selfmonitoring capability which simplifies installationand reduces maintenance by detecting any variationin performance. Ideal for a wide variety of waterdistribution and wastewater applications.

Page 3: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

the mainstream difference

n High sensitivity extends applications to “clean” watern Sophisticated ultrasound processing ignores spurious

signalsn Ultrasound signal quality monitor confirms

measurement integrityn Bidirectional flow velocity measurement, 10 mm/s to

5 m/s forward and 10 mm/s to 5 m/s reversen Channels or pipes from 150 mm to 3 m widen Guaranteed no zero offset or driftn Probe may be located up to 500 metres from the

system unitn Easy to use PC software simplifies commissioning and

product supportn Quick to install – no weirs or flumes

A unique feature for theMainstream is its signalquality reading. It calculatesthe percentage of the totalsignal that contains usefulvelocity information. Thisis an invaluable metricfor flowmeter conditionmonitoring.

Page 4: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

SIMPLE TO CUSTOMISE FORYOUR APPLICATIONS

benefits and features

n High sensitivity extends applications to ‘clean’ water

n Sophisticated ultrasound processing ignores spurioussignals

n Ultrasound signal quality monitor confirms measurementintegrity

n Real-time processing of velocity signals thereby reducingpower consumption

n Smart power saving mode - intelligent use of powersaving which automatically reduces the measurementtime for high flow velocities and high signal qualities andincreases the measurement time for low velocities andlow signal qualities

n Quick to install no weirs or flumes

n Powerful, easy to use PC software simplifies transmittercommissioning

n Streamlined velocity probe eliminates fouling andreduces flow disturbances

n Distances up to 500 meters from system unit to velocitysensor

n ATEX Zone 0 velocity sensor, options available

For flow measurement in open channels and partfilledpipes, with liquids from clean water to raw sewage,Mainstream flowmeters provide the highest qualityperformance at the most competitive price.

The velocity sensor may be located up to 500 metres fromthe system unit and measures flow velocities from less than10 mm/s up to 5 m/s.

The system unit displays liquid level, flow velocity, flowrate and totalized flow. Analog outputs transmit flowinformation and opto-isolated switches can activate alarmsor operate samplers. An integral data logger storesmeasured and calculated information for graphing oranalysis.

Easy to use PC software simplifies commissioning andproduct support. Features include a pointandclickgraphical interface to specify predefined or nonstandardpipe and channel crosssections and remote flowmeterdiagnostics via email.

Reliable, high performance and quick to install, Mainstreamultrasonic areavelocity flowmeters have found wideapplication internationally.

Page 5: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

applications

n Effluent Monitoring

n Waste Water Treatment

n Industrial Flow Measurement

n Irrigation Channels & Canals

n River/Stream Flow Measurement

n Water Distribution

n Sewer Flow Measurement (Inflow & Infiltration; CSOMonitoring)

n Portable and Fixed-site Flow Measurement withoutWeirs or Flumes

mainstream’s communicator datan Intuitive pointandclick user interface with pulldown

menus and Communicator’s dynamic/distinctivebutton bar for flowmeter configuration, diagnosticsand real-time displays

n Real time display of measurements and velocityhistogram

n Backup and restore of the Mainstreamconfiguration

Page 6: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

MAINSTREAMVELOCITYTRANSMITTER

High reliability velocitytransmitter designedfor use as a systemcomponent within largerapplications

PRODUCT OVERVIEW

PRODUCT COMPARISON CHART

MAINSTREAMPREMIER FIXEDAV-FLOWMETER

Superior performance withextended feature set forcomplex applications

MAINSTREAMAV-FLOWTRANSMITTER

High performance flowtransmitter for flowmeasurement

MAINSTREAMPORTABLEAV-FLOWMETER

Perfect for short term andextended field studies

MAINSTREAMCOMPACT FIXEDAV-FLOWMETER

Designed for basicoperations andcompetitively priced

Product

24V p

ower

12V lo

w p

ower

12V c

harg

er

Leve

l sen

sor

Velo

city

sens

or

Dat

a Lo

gger

LCD

Switc

h ou

tput

420m

A ou

tput

CO

MM

SRS23

2/U

SB

Package

Velocity Transmitter 3 3 7 7 1 7 7 7 1 3 220x120x80

Flow Transmitter 3 3 7 1 1 7 7 7 1 3 220x120x80

Compact FixedAV-Flowmeter

3 3 7 1 1 3 3 2 1 3 220x120x80

Premier FixedAV-Flowmeter

1228V 3 3 2 1 3 3 2 3 3 260x160x90

Portable Flowmeter 3 3 3 1 1 3 3 2 7 3PELI 1200

Orange

Page 7: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

MAINSTREAM SDI ADAPTER

The SDI12 Adapter connects to the MainstreamRS232 communications port and is mountedexternally to the Mainstream system unit. TheSDI12 Adapter, can be used to interface theMainstream with other devices using the SDI12protocol and is a readonly device, allowing theuser to read measurements from the Mainstreamover a 3wire interface. Devices suitable forinterfacing can include wireless telemetry unitsand larger industrial SCADA systems. This allowsthe Mainstream to be utilised in a wide variety ofapplications.

MAINSTREAM MODBUS ADAPTER

The Modbus Adapter is a device that is external tothe Mainstream and works by connecting to theMainstream communications port, allowing thecustomer to read measurement data using theModbus RTU protocol. The Adapter can operateusing Modbus RTU over RS232 or RS485 (half andfull duplex), it can accept external power suppliesand is currently available for use with fixed units.

Relays single or multiple measurements from theMainstream.

Configurable for fast operation or power savingoperation.

Builtin self diagnostics.

Many popular products such as telemetryunits and dataloggers incorporate Modbuscommunications. Many of these devices arealready embedded throughout the water industryinfrastructure, the Modbus Adapter bridges thegap between the Mainstream and these devices.

The Mainstream Modbus Adapter makes thereliability, accuracy and affordability of theMainstream, available to anyone who already hasthis technology in place or is looking to upgradetheir communications capabilities.

Page 8: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

OPTIONAL EXTRAS

ATEX ZONE 0VELOCITY SENSORFor use in Zone 0 andZone 1. SIRAapproved asATEX Group II category1G equipment (ATEXDirective 94/9/EC).Cable length no longerthan 300 metres.

STAINLESS STEELPROBE COVER &DIPPING STICK(Fixed and Portable)Robust and ideal for use indifficult flow conditions. Thestainless steel cover protectsthe probe from damage andthe dipping stick is availablein measured 1 metre lengthsup to 3 metres only.

Compatible with:All units

MOUNTING PLATE(Fixed andPortable)

POWER SUPPLY(Portable)

This stainless steel plateallows the velocity probeto be screwed onto theplate and inserted into theflow.

For use with theMainstream PortableAVflowmeter, a 24V,2A single output AC/DCSwitch Mode DesktopPower Supply with astandard IEC 320 C14input connector andHirschmann connector.

Compatible with:Portable Unit

BATTERYCHARGER(Portable)

The battery chargercharges all lead acidbatteries, with fullyautomatic charging; LEDindication of short circuit,reverse polarity & opencircuit and with a 1.8 mlong output lead fittedwith crocodile clips

Compatible with:Portable Unit

VELOCITY ANDLEVEL SIMULATOR

An important instrumentfor eliminating velocitysensor failure whenfault finding on site bysimulating flow and foreliminating level sensorfailure when fault findingon site by simulating level.

Page 9: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

RS232 COMMSCABLE(Fixed andPortable)PC Communication cablewith RS232 connector foruse with all Mainstreamtransmitters andflowmeters.

Compatible with:All units

BATTERYCONNECTORCABLE (Portable)

Binder connector with upto 2 metre length cable,secured by adhesive cableclips.

Compatible with:Portable Unit

AUXILIARY CABLE(Portable)For use with theMainstream PortableAVflowmeter this cablewill allow for connectionfor external power inputcompatible with solarpanels and industrial12V and 24V supplies.It includes two switchoutputs for remoteconnection.

Compatible with:Portable Unit

GEL BATTERY(Portable)

Sealed, deep dischargegel lead acid battery,7.5Ah capacity withnominal 12V voltage.Contains a thixotropic gelelectrolyte and is ideal forrepeated deep dischargeand recharge.

Compatible with:Portable Unit

USB COMMSCABLE(Fixed andPortable)PC Communication cablewith USB connector foruse with all Mainstreamtransmitters andflowmeters.

Compatible with:All units

Page 10: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

MAINSTREAM VELOCITY TRANSMITTERvelocity measurementTransducer Type : Submerged ultrasonic sensor containing signal generator, transmitter, receiver and decoder electronicsMethod : Phase Coherence time delay measurement determines the time for tracers carried by the flow to travel a

fixed distance (~ 0.75 mm)Velocity Range : 5 m/s to 10 mm/s and 10 mm/s to 5 m/sResolution : Better than 1 mm/sMeasurement Integrity : Ultrasound signal quality monitor gives the percentage of the measurement time that the received

ultrasound signal contains useful velocity informationSmart Power Saving : Each velocity measurement is based on the same quantity of information. Automatically reduces the

measurement time for high flow velocities and high signal qualities and increases the measurement time forlow velocities and low signal qualities

power suppliesPower Inputs : Terminals for external 12V and 24V suppliesExternal 12V supply : 12V input for low power battery operationExternal 24V supply : 24V input for industrial power suppliesPower Supply Monitor : Power monitoring circuits track supply status. Supply voltages can be viewed via the UI

communicationsLocal : RS232 and USB compatible interface with automatic baud rate detection. Supports 1200, 2400, 4800, 9600,

14400, 19200, 38400, 57600 and 115200 baudRemote : Optional external SDI or MODBUS deviceSoftware : Mainstream Communicator UI software for system configuration, diagnostics, real time measurement.

Display and data retrieval. Mainstream Communicator runs on PC platforms under Windows 2000, XP, Vista,7, 8, 8.1 and 10 with data transmission from device to PC, for data control, processing and export

measurands units and formatsPower Supply Voltage : VSignal Quality : %Velocity : Selectable from mm/s, cm/s, m/s, in/s, ft/s, ft/minDisplay Format : Independently configurable display format for each measurement. Options are integer, fixed point with 1 to

6 decimal places, and scientific (Eformat). Display defaults to scientific format if data cannot be correctlyrepresented in selected format

420mA outputHardware : One optoisolated passive 420mA output configurable to transmit any selected measurand

Isolated 12V supply derived from 24V power input for active 420mA output operation

PRODUCT HARDWAREvelocity sensorMaterials : Streamlined µPVC moulding and polyurethane cableDimensions : 105 mm long x 50 mm wide x 20 mm highCable : 8 mm diameter polyurethane cable with Aramid strain cord. Breaking load 45 kg.

Minimum static bend radius 52 mmWeight : 1 kg including standard 10 m cable lengthMaximum Cable Length : 500 mEnvironmental Protection : Totally encapsulated to IP68Operating Temperature : 10°C to 80°CMinimum Operating Depth : 30 mm

system unitMaterials : Ultra pure cast aluminiumDimensions : 220 mm wide x 120 mm deep x 80 mm highWeight : 1.5 kgEnvironmental Protection : Enclosure is IP67. Electronic assembly is encapsulated to IP68Operating Temperature : 10°C to 70°C

PRODUCT DATASHEETS

Page 11: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

MAINSTREAM AV-FLOW TRANSMITTERlevel measurementTransducer Type : Any 420mA current loop level sensorMethod : Pulse activation with configurable sensor warmup time. Loop current measurement by selfcalibrating 16

bit delta-sigma A-D converterCurrent Range : 030mAResolution : Better than 1µATransducer Calibration : Calibration table (maximum 23 points) with builtin interpolator converts loop current into level

measurement. Simple transducer calibration tool included in UI softwareInterchangability : Transducers and calibration data directly interchangeable between Mainstream system units

velocity measurementTransducer Type : Submerged ultrasonic sensor containing signal generator, transmitter, receiver and decoder electronicsMethod : Phase Coherence time delay measurement determines the time for tracers carried by the flow to travel a

fixed distance (~ 0.75 mm)Velocity Range : 5 m/s to 10 mm/s and 10 mm/s to 5 m/sResolution : Better than 1 mm/sMeasurement Integrity : Ultrasound signal quality monitor gives the percentage of the measurement time that the received ultrasound

signal contains useful velocity informationSmart Power Saving : Each velocity measurement is based on the same quantity of information. Automatically reduces the

measurement time for high flow velocities and high signal qualities and increases the measurement time forlow velocities and low signal qualities

derived measurementsArea : Flow crosssectional area calculated from the level measurement and the dimensions of the pipe or channel.

Calculation can take into account a specified (constant) silt level. Flow crosssection specification toolsincluded in UI software

Flow Rate : Fluid flow rate calculated by multiplying crosssectional area by flow velocity

power suppliesPower Inputs : Terminals for external 12V and 24V suppliesExternal 12V supply : 12V input for low power battery operationExternal 24V supply : 24V input for industrial power suppliesPower Supply Monitor : Power monitoring circuits track supply status. Supply voltages can be viewed via the UI

communicationsLocal : RS232 and USB compatible interface with automatic baud rate detection. Supports 1200, 2400, 4800, 9600,

14400, 19200, 38400, 57600 and 115200 baudRemote : Optional external SDI or MODBUS deviceSoftware : Mainstream Communicator UI software for system configuration, diagnostics, real time measurement

display and data retrieval. Mainstream Communicator runs on PC platforms under Windows 2000, XP, Vista,7, 8, 8.1 and 10 with data transmission from device to PC, for data control, processing and export

measurands units and formatsPower Supply Voltage : VSignal Quality : %Linear (pipe & channel Selectable from mm, cm, m, in, ftdimensions) :Level : Selectable from mm, cm, m, in, ftArea : Selectable from m2, cm2, mm2, in2, ft2Velocity : Selectable from mm/s, cm/s, m/s, in/s, ft/s, ft/minFlow Rate : Selectable from l/s, m3/s, ft3/s, igals/s, USG/s, 1/min, M3/min, ft3/minDisplay Format : Independently configurable display format for each measurement. Options are integer, fixed point with 1 to

6 decimal places, and scientific (Eformat). Display defaults to scientific format if data cannot be correctlyrepresented in selected format

420mA outputHardware : One optoisolated passive 420mA output configurable to transmit any selected measurand.

Isolated 12V supply derived from 24V power input for active 420mA output operation.

PRODUCT HARDWAREptx level sensorMaterials : Titanium, acetal and polyurethaneDimensions : 185 mm long x 17.5 mm diameterCable : 8 mm diameter vented polyurethane cable with Kevlar strain cordWeight : 1 kg including standard 10 m cable lengthLevel Range : 0 to 2 m working. Maximum 8 m overrangeResolution : Better than 1 mmCombined Accuracy : Combined effects of nonlinearity, hysterisis and repeatability better than 0.25% best straight line.

Non- linearity and offsets removed by transducer calibrationEnvironmental Protection : Fully encapsulated to IP68Operating Temperature : 20°C to 60°C (temperature compensated 2°C to 30°C)

Page 12: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

velocity sensorMaterials : Streamlined µPVC moulding and polyurethane cableDimensions : 105 mm long x 50 mm wide x 20 mm highCable : 8 mm diameter polyurethane cable with Aramid strain cord. Breaking load 45 kg. Minimum static bend

radius 52 mmWeight : 1 kg including standard 10 m cable lengthMaximum Cable Length : 500 mEnvironmental Protection : Totally encapsulated to IP68Operating Temperature : 10°C to 80°CMinimum Operating Depth : 30 mm

system unitMaterials : Ultra pure cast aluminiumDimensions : 220 mm wide x 120 mm deep x 80 mm highWeight : 1.65 kgEnvironmental Protection : Enclosure is IP67. Electronic assembly is encapsulated to IP68Operating Temperature : 10°C to 70°C

Page 13: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

MAINSTREAM COMPACT FIXED AV-FLOWMETERlevel measurementTransducer Type : Any 420mA current loop level sensorsMethod : Pulse activation with configurable sensor warmup time. Loop current measurement by selfcalibrating 16

bit delta-sigma A-D converterCurrent Range : 030mAResolution : Better than 1µATransducer Calibration : Calibration table (maximum 23 points) with builtin interpolator converts loop current into level

measurement. Simple transducer calibration tool included in UI softwareInterchangeability : Transducers and calibration data directly interchangeable between Mainstream system units

velocity measurementTransducer Type : Submerged ultrasonic sensor containing signal generator, transmitter, receiver and decoder electronicsMethod : Phase Coherence time delay measurement determines the time for tracers carried by the flow to travel a

fixed distance (~ 0.75 mm)Velocity Range : 5 m/s to 10 mm/s and 10 mm/s to 5 m/sResolution : Better than 1 mm/sMeasurement Integrity : Ultrasound signal quality monitor gives the percentage of the measurement time that the received ultrasound

signal contains useful velocity informationSmart Power Saving : Each velocity measurement is based on the same quantity of information. Automatically reduces the

measurement time for high flow velocities and high signal qualities and increases the measurement time forlow velocities and low signal qualities

derived measurementsArea : Flow crosssectional area calculated from the level measurement and the dimensions of the pipe or channel.

Calculation can take into account a specified (constant) silt level. Flow crosssection specification toolsincluded in UI software

Flow Rate : Fluid flow rate calculated by multiplying crosssectional area by flow velocityFlow Quantity : Three independent flow totalisers calculate forward only, reverse only, and forwardreverse flow quantities.

Each totaliser uses separate elements to accumulate hour quantity and total quantity to prevent roundofferrors

power suppliesPower Inputs : Terminals for external 12V and 24V suppliesExternal 12V supply : 12V input for low power battery operationExternal 24V supply : 24V input for industrial power suppliesPower Supply Monitor : Power monitoring circuits track supply status. Supply voltages can be displayed on LCD, viewed via the UI,

stored in the data logger, and used to control switch outputs

data loggerFile System : Flash file system with 4 Mbyte capacity and data retention of 20 yearsFile Content : Configurable to record any combination of power supply voltages, level sensor loop current, level, area,

ultrasound signal quality, velocity and flow rate, plus forward, reverse and total flow quantitiesRecording Mode : Proprietary data compression algorithm for extended logger capacity and rapid data retrievalRecording Interval : Configurable from 15 seconds to 1 hourData Capacity : Logger holds more than one year of data when recording all available measurements at one minute intervalsRetrieval Time : Less than 15 seconds to retrieve one month’s data recorded at 1 minute intervals. File synchronization

capability for fast update of previously retrieved data filesRetrieved Data Format : Spreadsheet compatible .csv file with country specific caption text and date/time format for analysis and

reports. Flash file image file including complete flowmeter configuration for data archives

communicationsLocal : RS232 and USB compatible interface with automatic baud rate detection. Supports 1200, 2400, 4800, 9600,

14400, 19200, 38400, 57600 and 115200 baudRemote : Optional external SDI or MODBUS deviceSoftware : Mainstream Communicator UI software for system configuration, diagnostics, real time measurement

display and data retrieval. Mainstream Communicator runs on PC platforms under Windows 2000, XP, Vista,7, 8, 8.1 and 10 with data transmission from device to PC, for data control, processing and export

user interfacesLCD : Two line x 16 character LCD. Configurable display sequence includes date, time, and any combination of

measurement data. Country specific caption text and date/time format. Configurable backlight operation.LCD always on or activated by front panel push switch

measurands units and formatsPower Supply Voltage : VSignal Quality : %Linear (pipe & channel Selectable from mm, cm, m, in, ftdimensions) :Level : Selectable from mm, cm, m, in, ftArea : Selectable from m2, cm2, mm2, in2, ft2Velocity : Selectable from mm/s, cm/s, m/s, in/s, ft/s, ft/minFlow Rate : Selectable from l/s, m3/s, ft3/s, igal/s, USG/s, l/min, m3/min, ft3/min, igal/min, USG/min, m3/h, ft3/h,

m3/d, Ml/d

Page 14: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

Quantity : Selectable from l, m3, Ml, ft3, igal, USGDisplay Format : Independently configurable display format for each measurement. Options are integer, fixed point with 1 to

6 decimal places, and scientific (Eformat). Display defaults to scientific format if data cannot be correctlyrepresented in selected format

switch outputsHardware : Two optoisolated switches rated at 60V ac/dc and 200mA maximum current. Each switch independently

configurable for state output or pulse output operationState Output : Switch configurable to respond to any item of measured data with separate switch open and switch close

settings to provide hysterisis. Applications include power supply monitoring and control, low ultrasoundsignal quality indication and level, velocity and flow alarms

Pulse Output : Switch configurable to generate a 2.5 second duration switch closure to indicate a defined flow quantity.Applications include sampler control and remote flow totaliser operation

420mA outputHardware : One optoisolated passive 420mA output configurable to transmit any selected measurand

Isolated 12V supply derived from 24V power input for active 420mA output operation

PRODUCT HARDWAREptx level sensorMaterials : Titanium, acetal and polyurethaneDimensions : 185 mm long x 17.5 mm diameterCable : 8 mm diameter vented polyurethane cable with Kevlar strain cordWeight : 1 kg including standard 10 m cable lengthLevel Range : 0 to 2 m working. Maximum 8 m overrangeResolution : Better than 1 mmCombined Accuracy : Combined effects of nonlinearity, hysterisis and repeatability better than 0.25% best straight line.

Non-linearity and offsets removed by transducer calibrationEnvironmental Protection : Fully encapsulated to IP68Operating Temperature : 20°C to 60°C (temperature compensated 2°C to 30°C)

velocity sensorMaterials : Streamlined µPVC moulding and polyurethane cableDimensions : 105 mm long x 50 mm wide x 20 mm highCable : 8 mm diameter polyurethane cable with Aramid strain cord. Breaking load 45 kg. Minimum static bend

radius 52 mmWeight : 1 kg including standard 10 m cable lengthMaximum Cable Length : 500 m; 300 m for ATEXEnvironmental Protection : Totally encapsulated to IP68Operating Temperature : 10°C to 80°CMinimum Operating Depth : 30 mm

system unitMaterials : Ultra pure cast Aluminium housingDimensions : 220 mm wide x 120 mm deep x 80 mm highWeight : 1.9 kgEnvironmental Protection : Enclosure is IP67. Electronic assembly is encapsulated to IP68Operating Temperature : 10°C to 70°C

Page 15: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

MAINSTREAM PREMIER FIXED AV-FLOWMETERlevel measurementTransducer Type : Dual 420mA current loop level sensorsMethod : Pulse activation with configurable sensor warmup time. Loop current measurement by selfcalibrating 16bit

delta-sigma A-D converterCurrent Range : 030mAResolution : Better than 1µATransducer Calibration : Calibration tables (maximum 23 points) with builtin interpolator convert loop currents into level

measurements. Simple transducer calibration tool included in UI softwareInterchangeability : Transducers and calibration data directly interchangeable between Mainstream system units

velocity measurementTransducer Type : Submerged ultrasonic sensor containing signal generator, transmitter, receiver and decoder electronicsMethod : Phase Coherence time delay measurement determines the time for tracers carried by the flow to travel a

fixed distance (~ 0.75 mm)Velocity Range : 5 m/s to 10 mm/s and 10 mm/s to 5 m/sResolution : Better than 1 mm/sMeasurement Integrity : Ultrasound signal quality monitor gives the percentage of the measurement time that the received ultrasound

signal contains useful velocity informationSmart Power Saving : Each velocity measurement is based on the same quantity of information. Automatically reduces the

measurement time for high flow velocities and high signal qualities and increases the measurement time forlow velocities and low signal qualities

derived measurementsArea : Flow crosssectional area calculated from the level measurement and the dimensions of the pipe or channel.

Calculation can take into account a specified (constant) silt level. Flow crosssection specification toolsincluded in UI software

Flow Rate : Fluid flow rate calculated by multiplying crosssectional area by flow velocity.Flow Quantity : Three independent flow totalisers calculate forward only, reverse only, and forwardreverse flow quantities. Each

totaliser uses separate elements to accumulate hour quantity and total quantity to prevent roundoff errors

power suppliesPower Inputs : Terminals for external 12V and 24V suppliesExternal 12V supply : 12V input for low power battery operationExternal 24V supply : Isolated 1528V input for industrial power suppliesBattery Charger : Builtin battery charger maintains external 12V battery using power from the 1528V source creating an

uninterruptable power supply for fail safe operationPower Supply Monitor : Power monitoring circuits track supply status. Supply voltages and charged current can be displayed on LCD,

viewed via the UI, stored in the data logger, and used to control switch outputs.

data loggerFile System : Flash file system with 4 Mbyte capacity and data retention of 20 yearsFile Content : Configurable to record any combination of power supply voltages, battery charge current, level sensor loop

current, level, area, ultrasound signal quality, velocity and flow rate, plus forward, reverse and total flowquantities

Recording Mode : Proprietary data compression algorithm for extended logger capacity and rapid data retrievalRecording Interval : Configurable from 15 seconds to 1 hourData Capacity : Logger holds more than one year of data when recording all available measurements at one minute intervalsRetrieval Time : Less than 15 seconds to retrieve one month’s data recorded at 1 minute intervals. File synchronization

capability for fast update of previously retrieved data filesRetrieved Data Format : Spreadsheet compatible .csv file with country specific caption text and date/time format for analysis and

reports. Flash file image file including complete flowmeter configuration for data archives

communicationsLocal : RS232 and USB compatible interface with automatic baud rate detection. Supports 1200, 2400, 4800, 9600,

14400, 19200, 38400, 57600 and 115200 baudRemote : Optional external SDI or MODBUS device

user interfacesSwitch : Push to start LCD displayLCD : Two line x 16 character LCD. Configurable display sequence includes date, time, and any combination of

measurement data. Country specific caption text and date/time format. Configurable backlight operation.LCD always on or activated by front panel push switch

measurands units and formatsPower Supply Voltage : VSignal Quality : %Linear (pipe & channel Selectable from mm, cm, m, in, ftdimensions) :Level : Selectable from mm, cm, m, in, ftArea : Selectable from m2, cm2, mm2, in2, ft2Velocity : Selectable from mm/s, cm/s, m/s, in/s, ft/s, ft/minFlow Rate : Selectable from l/s, m3/s, ft3/s, igal/s, USG/s, l/min, m3/min, ft3/min, igal/min, USG/min, m3/h, ft3/h,

m3/d, Ml/d

Page 16: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

Quantity : Selectable from l, m3, Ml, ft3, igal, USGDisplay Format : Independently configurable display format for each measurement. Options are integer, fixed point with 1 to

6 decimal places, and scientific (Eformat). Display defaults to scientific format if data cannot be correctlyrepresented in selected format

switch outputsHardware : Two optoisolated switches rated at 60V ac/dc and 200mA maximum current. Each switch independently

configurable for state output or pulse output operationState Output : Switch configurable to respond to any item of measured data with separate switch open and switch close

settings to provide hysterisis. Applications include power supply monitoring and control, low ultrasoundsignal quality indication and level, velocity and flow alarms

Pulse Output : Switch configurable to generate a 2.5 second duration switch closure to indicate a defined flow quantity.Applications include sampler control and remote flow totaliser operation

420mA outputsHardware : Three optoisolated passive 420mA outputs, each configurable to transmit any selected measurand

Isolated 12V supply derived from 1528V power input for active 420mA output operation

PRODUCT HARDWAREptx level sensorMaterials : Titanium, acetal and polyurethaneDimensions : 185 mm long x 17.5 mm diameterCable : 8 mm diameter vented polyurethane cable with Kevlar strain cordWeight : 1 kg including standard 10 m cable lengthLevel Range : 0 to 2 m working. Maximum 8 m overrangeResolution : Better than 1 mmCombined Accuracy : Combined effects of nonlinearity, hysterisis and repeatability better than 0.25% best straight line.

Non-linearity and offsets removed by transducer calibrationEnvironmental Protection : Fully encapsulated to IP68Operating Temperature : 20°C to 60°C (temperature compensated 2°C to 30°C)

velocity sensorMaterials : Streamlined µPVC moulding and polyurethane cableDimensions : 105 mm long x 50 mm wide x 20 mm highCable : 8 mm diameter polyurethane cable with Aramid strain cord. Breaking load 45 kg. Minimum static bend

radius 52 mmWeight : 1 kg including standard 10 m cable lengthMaximum Cable Length : 500 m; 300 m for ATEX Zone 0Environmental Protection : Totally encapsulated to IP68Operating Temperature : 10°C to 80°CMinimum Operating Depth : 30 mm

system unitMaterials : Ultra pure cast Aluminium housingDimensions : 260 mm wide x 160 mm deep x 90 mm highWeight : 2.95 kgEnvironmental Protection : Enclosure is IP67. Electronic assembly is encapsulated to IP68Operating Temperature : 10°C to 70°C

Page 17: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

MAINSTREAM PORTABLE AVFLOWMETERlevel measurementTransducer Type : Any 420mA current loop level sensorMethod : Pulse activation with configurable sensor warmup time. Loop current measurement by selfcalibrating 16bit

delta-sigma A-D converterCurrent Range : 030mAResolution : Better than 1µATransducer Calibration : Calibration table (maximum 23 points) with builtin interpolator converts loop current into level

measurement Simple transducer calibration tool included in UI softwareInterchangeability : Transducers and calibration data directly interchangeable between Mainstream system units

velocity measurementTransducer Type : Submerged ultrasonic sensor containing signal generator, transmitter, receiver and decoder electronicsMethod : Phase Coherence time delay measurement determines the time for tracers carried by the flow to travel a

fixed distance (~ 0.75 mm)Velocity Range : 5 m/s to 10 mm/s and 10 mm/s to 5 m/sResolution : Better than 1 mm/sMeasurement Integrity : Ultrasound signal quality monitor gives the percentage of the measurement time that the received ultrasound

signal contains useful velocity informationSmart Power Saving : Each velocity measurement is based on the same quantity of information. Automatically reduces the

measurement time for high flow velocities and high signal qualities and increases the measurement time forlow velocities and low signal qualities

derived measurementsArea : Flow crosssectional area calculated from the level measurement and the dimensions of the pipe or channel.

Calculation can take into account a specified (constant) silt level. Flow crosssection specification toolsincluded in UI software

Flow Rate : Fluid flow rate calculated by multiplying crosssectional area by flow velocityFlow Quantity : Three independent flow totalisers calculate forward only, reverse only, and forwardreverse flow quantities.

Each totaliser uses separate elements to accumulate hour quantity and total quantity to prevent roundofferrors

power suppliesPower Inputs : Internal 12V battery. Connectors for external 12V and 24V DC suppliesInternal Battery : Low cost exchangeable deep discharge 12V 7.5Ah rechargeable battery. One year endurance when operated

at 1 measurement per minute. Weight 2.5 kgExternal 12V supply : Connection for external 12V battery pack for extended measurement periodExternal 24V supply : Connection for external 1528V power input compatible with all industrial 24V suppliesBattery Charger : Builtin battery charger maintains internal 12V battery using power from external 24V source, enabling

power harvesting for indefinite endurancePower Supply Monitor : Power monitoring circuits track supply status. Supply voltages and charge currents can be displayed on LCD,

viewed via the UI, stored in the data logger, and used to control switch outputs. Power supply conditionvisible on status LED

data loggerFile System : Flash file system with 4 Mbyte capacity and data retention of 20 yearsFile Content : Configurable to record any combination of power supply voltages, battery charge current, level sensor loop

current, level, area, ultrasound signal quality, velocity and flow rate, plus forward, reverse and total flowquantities

Recording Mode : Proprietary data compression algorithm for extended logger capacity and rapid data retrievalRecording Interval : Configurable from 15 seconds to 1 hourData Capacity : Logger holds more than one year of data when recording all available measurements at one minute intervalsRetrieval Time : Less than 15 seconds to retrieve one month’s data recorded at 1 minute intervals. File synchronization

capability for fast update of previously retrieved data filesRetrieved Data Format : Spreadsheet compatible .csv file with country specific caption text and date/time format for analysis and

reports. Flash file image file including complete flowmeter configuration for data archives

communicationsLocal : RS232 and USB compatible interface with automatic baud rate detection. Supports 1200, 2400, 4800, 9600,

14400, 19200, 38400, 57600 and 115200 baudRemote : Optional external SDI or MODBUS deviceSoftware : Mainstream Communicator UI software for system configuration, diagnostics, real time measurement

display and data retrieval. Mainstream Communicator runs on PC platforms under Windows 2000, XP, Vista,7, 8, 8.1 and 10 with data transmission from device to PC, for data control, processing and export

user interfacesOn/Off Switch : Push to start push to stop. Requires 10 seconds continuous pressure to switch flowmeter off to prevent

accidental de-activationStatus LED : High intensity flashing LED indicates system operation and battery status without opening enclosure or

entering manhole. LED also indicates activity on communications portLCD : Two line x 16 character LCD. Automatic activation when integral light sensor detects enclosure is open.

Configurable display sequence includes date, time, and any combination of measurement data. Countryspecific caption text and date/time format

Page 18: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

measurands units and formatsPower Supply Voltage : VSignal Quality : %Linear (pipe & channel Selectable from mm, cm, m, in, ftdimensions) :Level : Selectable from mm, cm, m, in, ftArea : Selectable from m2, cm2, mm2, in2, ft2Velocity : Selectable from mm/s, cm/s, m/s, in/s, ft/s, ft/minFlow Rate : Selectable from l/s, m3/s, ft3/s, igal/s, USG/s, l/min, m3/min, ft3/min, igal/min, USG/min, m3/h, ft3/h,

m3/d, Ml/dQuantity : Selectable from l, m3, Ml, ft3, igal, USGDisplay Format : Independently configurable display format for each measurement. Options are integer, fixed point with 1 to

6 decimal places, and scientific (Eformat). Display defaults to scientific format if data cannot be correctlyrepresented in selected format

switch outputsHardware : Two optoisolated switches rated at 60V ac/dc and 200mA maximum current. Each switch independently

configurable for state output or pulse output operationState Output : Switch configurable to respond to any item of measured data with separate switch open and switch close

settings to provide hysterisis. Applications include power supply monitoring and control, low ultrasoundsignal quality indication and level, velocity and flow alarms

Pulse Output : Switch configurable to generate a 2.5 second duration switch closure to indicate a defined flow quantity.Applications include sampler control and remote flow totaliser operation

PRODUCT HARDWAREptx level sensorMaterials : Titanium, acetal and polyurethaneDimensions : 185 mm long x 17.5 mm diameterCable : 8 mm diameter vented polyurethane cable with Kevlar strain cordWeight : 1 kg including standard 10 m cable lengthLevel Range : 0 to 2 m working. Maximum 8 m overrangeResolution : Better than 1 mmCombined Accuracy : Combined effects of nonlinearity, hysterisis and repeatability better than 0.25% best straight line.

Non-linearity and offsets removed by transducer calibrationEnvironmental Protection : Fully encapsulated to IP68Operating Temperature : 20°C to 60°C (temperature compensated 2°C to 30°C)

velocity sensorMaterials : Streamlined µPVC moulding and polyurethane cableDimensions : 105 mm long x 50 mm wide x 20 mm highCable : 8 mm diameter polyurethane cable with Aramid strain cord. Breaking load 45 kg. Minimum static bend

radius 52 mmWeight : 1 kg including standard 10 m cable lengthMaximum Cable Length : 500 m; 300 m for ATEX Zone 0Environmental Protection : Totally encapsulated to IP68Operating Temperature : 10°C to 80°CMinimum Operating Depth : 30 mm

system unitMaterials : Ultra high impact structural copolymer polypropyleneDimensions : 280 mm wide x 250 mm deep x 125 mm highWeight : 5 kg with 7.5Ah internal battery installedEnvironmental Protection : Enclosure is IP67. Electronic assembly is encapsulated to IP68 and can operate totally submerged with the

enclosure lid openOperating Temperature : 10°C to 70°C

Page 19: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

MAINSTREAM MODBUS ADAPTERpower suppliesMainstream : Mainstream units with appropriate firmware upgrade can power the Modbus adapter via the RS232

communications cableModbus : Terminals for 4.518V power input supplied via the Modbus masterAuxiliary : Terminals for 4.518V power input from an external power sourceIsolation : Mainstream system unit is isolated from the Modbus/auxiliary power inputsPower consumption : 50mA maximum operating current

communicationsMainstream : Male connector on 1m lead mates with Mainstream communications connectorModbus : Terminals for digitallyisolated RS232 and RS485 connectionsRS232 Communications : 1200, 2400, 4800, 9600, 19200 (default), 38400, 57600 and 115200 baud rates. None, odd or even parity.RS485 Communications : Full or half duplex. 1200, 2400, 4800, 9600, 19200 (default), 38400, 57600 and 115200 baud rates. None,

odd or even parity. Address range 1247. ¼ unit load (48Ω)

user interfacesModbus configuration : Two internal DIP switches to select RS232 or RS485 communication and full/half duplex when operating in

RS485 modeAddress configuration : Three internal 10 position digital encoders to set adapter addressDiagnostics: Three external LEDs to indicate operating status

system unitMaterials : Ultra pure cast aluminiumDimensions : 150 mm wide x 36 mm deep x 64 mm highWeight : 500 gOperating Temperature : 10ºC to 85ºC

MAINSTREAM SDI ADAPTERpower suppliesADCON cable : Cable carries a 6V power supplyPower Consumption : Idle < 20µA, communicating over SDI < 2mA, Communicating with Mainstream < 10mA

communicationsMainstream : Male connector on 0.5m lead mates with Mainstream communications connectorSDI12 : ADCON connector on 0.5m lead communicates over Serial Data Interface at 1200 baud

system unitMaterials : Ultra pure cast aluminiumDimensions : 98 mm wide X 34 mm deep X 64 mm highWeight : 300 gOperating temperature : 10°C to 85°C

Page 20: MAINSTREAM€MEASUREMENTS PRODUCT GUIDE

Mainstream MeasurementsMainstream House | Elmsley StreetSteeton-with-Eastburn | West Yorkshire BD20 6SE | UK

+ 44 (0) 1535 [email protected]

V22019

for more information please contact: