16
HUAWEI TECHNOLOGIES CO., L TD. All right s reser ved www.huawei.com Internal SmartAX MA5616  Additional

MA5616 Addinitional.ppt

Embed Size (px)

Citation preview

Page 1: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 1/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

www.huawei.com

Internal

SmartAX MA5616

Additional

Page 2: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 2/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 1

With the growing demand for integrateddata, video, voice and multimedia services,

the access networks are required to providehigh data rate and good quality services.

Understanding the requirements of globalmarket, Huawei has launched its SmartAX

MA5616 Multi-service Access Module.

Page 3: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 3/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2

Upon completion of this course, you will be able to:Describe the PITP parameter

Describe the Broadband Service Power off after AC down

Describe how to shut down the power for oneboard by remote

Service Emulation

Describe the FE isolation & Rate limitation.

Environment Monitor

Page 4: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 4/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3

It is the same with MA5600:

anid atm frame/slot/subslot/port:vpi.vci

anid eth frame/slot/subslot/port: vlanid

Note:1. If there are CVLAN at service- port , the “ vlanid ” is CVLAN; and if there is none CVLAN at service -

port, the “ vlanid ” is SVLAN.

2. When we deploy the “PTM” mode of VDSL and FE service, the keyword will be “eth”, and if it is thetraditional ADSL service or “ATM” mode of VDSL, the key word will be “atm”.

Page 5: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 5/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4

broad-service power-off shutdown

undo broad-service power-off shutdown

Note:1. The broad-service power-off shutdown command is used to enable the device to stop the

broadband service when the AC power supply is cut off and the battery is used for power supply.When the battery is used for power supply, you can run this command to stop the broadbandservice so that the narrowband service works for a longer time.

2. The undo broad-service power-off shutdown command is used to cancel the configuration inwhich the device stops the broadband service when the AC power supply is cut off and the batteryis used for power supply.

Page 6: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 6/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5

board power-on frameid/slotid

board power-off frameid/slotid

Note:

1. This command “ board power-on frameid/slotid ” is used to power on a service board remotely.

2. This command “ board power-off frameid/slotid” is used to power off a service board remotely.

3. When a service board of the MA5616 is faulty, you can run the board power-off command to poweroff and then run the board power-on command to power on the service board remotely to check

whether the hardware of the service board is normal. After this command is executed successfully,the service board is powered on and is registered again.

Page 7: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 7/16HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6

PPPOE simulation

POTS emulation call

Page 8: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 8/16HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7

PPPOE simulation

Note:huawei(config)#pppoe simulate

{ start<K>|stop<K> }:start

Service-port(index<0-999>):0

User Name(length<1,65>):user-0

User Password(length<0,16>):*******

Authentication Mode: 1. Chap 2. Pap [default 1]:1

Overtime Time(5-60s)[default 5]:10

huawei#display pppoe simulate info

Service-port: 0

User name: user-0

Current phase: Discovery

Result: -Start time: 2009-05-12,08:49:23+08:00

End time: -

Session ID: -

User IP: -

Gateway IP: -

Page 9: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 9/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8

POTS emulation call

Note:pots emulational-call caller-port frameid/slotid/portid callee-port frameid/slotid/portid callee-

telno telno-vlaue

undo pots emulational

huawei(config-test)#pots emulational-call

{caller-port<K>}:caller-port

{ frameid/slotid/portid<S><Length 1-15> }:0/1/1

{callee-port<K>}:callee-port

{ frameid/slotid/portid<S><Length 1-15> }:0/1/2

{ callee-telno<K> }:callee-telno

{ telno-vlaue<S><Length 1-16> }:88880000

Command:pots emulational-call caller-port 0/1/1 callee-port 0/1/2 callee-telno 88880000

Page 10: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 10/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9

By nature, every FE port are isolated

If we want to limit the physical speed of FE port, we can usecommand “ line-rate integer port frameid/slotid/portid ”.

Note:1. line-rate integer port frameid/slotid/portid

undo line-rate port frameid/slotid/portid

integer: 64-1000000 kbit/s.

Page 11: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 11/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10

Cable One End Is Connected to The Other End Is Connected to

Environment monitoring cable

ALARM port on the control board

Temperature sensor

Door status sensor

Lightning arrester

Fan

Battery monitoring cable SENSOR port on the power board Battery temperature sensor

Page 12: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 12/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11

huawei(config)#emu add 3 H831PMU 0 7 RS485

huawei(config)#interface emu 3

huawei(config-if-h831pmu-3)#display power system parameter

EMU ID: 3 Power system information

----------------------------------------------------------------------------

Charge control state: Remote control

Equalizing voltage : 56.80V Floating voltage : 55.00V

Charge Lmt quotiety : 0.15 Equalizing time : 90 days

Battery number : 1 Battery 0 capacity : 12 AH

Battery off permit : Permit Battery off voltage : 44.00V

DC over alarm volt : 59 V DC lack alarm voltage : 48 V

Power-cut-close-Broad-service : On

----------------------------------------------------------------------------

Page 13: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 13/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12

Page 14: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 14/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13

Page 15: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 15/16

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14

huawei(config)#emu add 2 POWER4830 0 4 RS485 POWER4830

huawei(config)#interface emu 2

huawei(config-if-power4830-2)#display power system parameter

EMU ID: 2 Power system information ----------------------------------------------------------------------------Charge control state: Automatic control Equalizing voltage : 56.50V Floating voltage :53.50V Charge Lmt quotiety : 0.15 Equalizing time : 60 days Battery number : 1 Battery 0capacity : 65 AH battery temperature test upper : 80C battery temperature test lower: -20Ctemperature redeem quotiety : 80mV battery temperature alarm upper: 50C batterytemperature alarm lower: 0C Battery off permit : Permit Battery off voltage : 43.00V AC overalarm volt : 280V AC lack alarm voltage : 180V DC over alarm volt : 58 V DC lack alarmvoltage : 45 V Power module number : 2 module 0 address: 1 module 0 switch state : Onmodule 1 address: 2 module 1 switch state : On Battery high-temperature-off permit : ForbidBattery high-temperature-off temperature: 53 C ----------------------------------------------------------------

------------

Page 16: MA5616 Addinitional.ppt

8/10/2019 MA5616 Addinitional.ppt

http://slidepdf.com/reader/full/ma5616-addinitionalppt 16/16

www.huawei.com

Thank You