41
Lynda Paleshnuik | January 2012 1 | Quality Workshop Copenhagen – January 2012 Assessing specificat ions: FPP (solid orals)

Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Embed Size (px)

Citation preview

Page 1: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 20121 |

Quality WorkshopCopenhagen – January 2012

Quality WorkshopCopenhagen – January 2012

Assessing specifications:

FPP

(solid orals)

Page 2: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 20122 |

OutlineOutline

Compendial versus in-house standards:

● When compendial standard is claimed

● When in-house standard is claimed

● When compendial methods are used

● When in-house methods are used but compendial standard is claimed

Page 3: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 20123 |

OutlineOutline

● Specific parameters in brief

● Unnecessary tests in specifications

● Example specifications exercise

● Review tips

Page 4: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 20124 |

Specifications Specifications

The set of criteria to which a FPP should conform to be considered acceptable for its intended use.

A list of tests, reference to analytical procedures, and acceptance criteria (numerical limits, ranges or other criteria) [ICH Q6A]

Confirm the quality, rather than fully characterize, the FPP

Page 5: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 20125 |

Specifications Specifications

Specifications should include, at minimum, tests for appearance, identification, assay, purity, performance tests (e.g. dissolution), physical tests (e.g. loss on drying, hardness, friability, particle size), uniformity of dosage units, and as applicable, identification and assay of antimicrobial or chemical preservatives (e.g. antioxidants) and microbial limit tests.

Several guidelines outline tests in addition to those in Q6A, e.g. for other dosage forms: New WHO PQP quality guideline P.5.1Other regulatory guidelines (e.g. HC, EMA)Pharmacopoeia

Page 6: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 20126 |

Officially recognized pharmacopoeiaOfficially recognized pharmacopoeia

PhInt, USP, BP, EP, JP are recognized standards in PQP

PhInt S2 available as CD-ROM or on-line

Page 7: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 20127 |

Validation, verification, equivalency, SST(assay and purity methods)

Validation, verification, equivalency, SST(assay and purity methods)

Validation: full validation required for in-house methods, generally specificity, linearity, accuracy, repeatability, intermediate precision, plus for purity: LOD/LOQ.

Verification: required for most compendial methods Equivalency: required for an in-house method, when

compendial standard is claimed SST: part of methodology, parameters determined via

robustness; tested every time the method is run to ensure adequate performance

NB: CU and dissolution are assay methods, residual solvents (organic granulating solvents) is a purity method

Page 8: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 20128 |

When compendial standard is claimed When compendial standard is claimed

1. Generally, the monograph tests and limits should be adopted.

2. The monograph is the minimum standard; the authority can impose additional requirements (e.g. ICH IT for individual unspecified related compounds)

3. All monograph tests/limits need not be included in specifications (may use in-house methods, provide justification for not including certain parameters).

But The product must comply with the monograph, if tested (see equivalency testing).

Page 9: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 20129 |

When compendial standard is claimed When compendial standard is claimed

BP “Official Standards” and EP “General Statements”:

An article is not of pharmacopoeial quality unless it meets all monograph requirements. However, performance of all tests is not necessarily required to assess compliance before release. Assurance of pharmacopoeial quality may instead be obtained from validation studies of the manufacturing process and from IPCs.

Page 10: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201210 |

When in-house standard is claimed When in-house standard is claimed

1. Generally, the tightest available monograph limits for assay and purity should be adopted (assay) or justified (specified related compounds). Justification is more difficult for the FPP because related compounds are mainly degradants in the monographs (but not always).

2. The available monographs can still be used as a general guideline for requirements

Page 11: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201211 |

When compendial methods are claimed… (purity and assay methods)

When compendial methods are claimed… (purity and assay methods)

Ensure they have really adopted the method as is. If not:

Check the deviations against published accepted deviations:

USP <621> Chromatography

EP 2.2.46 Chromatographic separation techniques

Note that there are specific SST RSD limits for EP and USP methods. If these methods are adopted, so should be the SST requirements.

Page 12: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201212 |

When compendial methods are adoptedWhen compendial methods are adopted

Verification data is required:

The compendial methods as published are typically validated based on an API or an FPP originating from a specific manufacturer. Different sources of the same API or FPP can contain impurities and/or degradation products that were not considered during the development of the monograph. Therefore the monograph and compendial method should be demonstrated suitable to control the impurity profile of the API from the intended source(s).

The FPP may also contain excipients not present in the FPP(s) for which the the compendial method was developed.

Page 13: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201213 |

When compendial methods are adoptedWhen compendial methods are adopted

Verification data:

Assay method: specificity, accuracy and repeatability (method precision).

Related substances method: full validation for any additional (to the monograph) specified related substances and absence of interference from placebo; If there is no monograph limit on individual unknowns (or it is higher than the IT/acceptable limit), repeatability of the API at the limit for unknowns (usually 0.2%) should be established.

Page 14: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201214 |

Compendial standard claimed, but in-house method used

Compendial standard claimed, but in-house method used

Full validation is required for an in-house purity/assay method.

In addition, if compendial standard is claimed, equivalency must be demonstrated compared to the compendial method (assay: assaying aliquots of the same samples using the two methods; related compounds: as above, spiking samples with specified related compounds at the limits)

If they can not demonstrate this, they may claim in-house standard but not compendial standard

Note that a compendial method becomes an in-house method when adjustments are made outside the allowable adjustments

Page 15: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201215 |

Equivalency - noteEquivalency - note

Equivalency is essentially two things:

Ensure the in-house method is not inferior (in which case they should adopt the compendial method)

Ensure the compendial test can be met, if applied.

Two samples are sufficient.

Page 16: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201216 |

QuestionQuestion

Q: Compendial standard is claimed.

The compendial monograph uses a TLC method. The in-house method is HPLC, which is an improvement over TLC. Is the applicant required to provide equivalency testing?

A: Demonstrating “equivalency” per se is not so important, but the product must still pass the compendial tests if tested, or they must change to an in-house standard.

Page 17: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201217 |

ExampleExample

USP standard claimed for FPP, in-house assay/degradation methods used, plus the USP degradation test is included in specs.

First assessor asks for equivalency data; 2nd says no with the following justification: a) “The in-house assay method is very similar to that of the USP method. The only differences are pH of the buffer soln (2.2 vs 3.3), ratio of the mobile phase to buffer (66:11 vs 88:12), and with respect to diluents used.”

b) “The applicant’s method is same as the draft PhInt (except w.r.t diluent) and has been sufficiently validated including specificity through forced degradation studies.”

Page 18: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201218 |

ExampleExample

Adjustment of method outside <621> (NMT 0.2 pH units, NMT 10% absolute change in MP%)

Similarity to PhInt method is immaterial (plus a draft monograph is referenced)… USP standard is claimed.

In this case equivalency is required for the assay method, but not for the degradation method. Why?

In the specs the USP degradation method is applied as well as the in-house method. Equivalency is to demonstrate the monograph standards are met if tested. USP testing for degradants will be met.

Page 19: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201219 |

Specification ParametersDescription

Specification ParametersDescription

Description: should be detailed (colour, shape, coating, markings (score, ink, embossing))

A complete description is also required to facilitate the visual identification of spurious/falsely-labelled/falsified/counterfeit (SFFC) medicines.

FPPs for which taste is critical (especially paediatrics): dispersible, sublingual/buccal, soluble, effervescent, and chewable tablets, and powders and granules for dispersion/solution or to be used as sprinkles.

Page 20: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201220 |

Specification ParametersDescription

Specification ParametersDescription

Palatability (including taste) should be demonstrated as part of pharmaceutical development. Taste may exceptionally be part of specs if an artificial taster is available. (Ideally would be in shelf-life specs).

Descriptions in compendial monographs:

“Statements given under this heading are not to be interpreted in a strict sense and are not to be regarded as analytical requirements.” [PhInt, BP, EP etc]

Page 21: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201221 |

Specification ParametersIdentification

Specification ParametersIdentification

Identification - establish the identity of the API(s) in the FPP and discriminate between compounds of closely related structure which are likely to be present. Identity tests should be specific for the API, e.g., IR spectroscopy. [stated for FPP as well as API in Q6A, although rarely seen in FPP specs]

Identification solely by a single chromatographic retention time, for example, is not regarded as being specific. However, the use of two chromatographic procedures, where the separation is based on different principles, or combination of tests into a single procedure, such as HPLC/UV diode array, HPLC/MS, or GC/MS, is generally acceptable. (Q6A)

Page 22: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201222 |

Specification ParametersIdentification

Specification ParametersIdentification

Note that for PQP, we have recently removed the requirement to include a test for the identification of colourant(s) in specifications.

[This is no longer in the Q guideline.]

Page 23: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201223 |

Specification ParametersIdentification

Specification ParametersIdentification

Q: When might identification of the salt in the FPP be a critical parameter?

A: When there is a risk of in-situ conversion during FPP manufacture. [Beware of bicarbonates and hydroxides (K, Na) in the formulation, except in minor amounts to adjust pH.]

Pharmaceutical equivalence definitions are about the API form “contained” in a product, not what it is “formulated with”.

Page 24: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201224 |

Specification ParametersAssay and Related Compounds

Specification ParametersAssay and Related Compounds

Assay: may be non-specific, e.g. titration, but need to achieve overall specificity, e.g. non-specific assay plus suitable related substances test.

Limits should be 95.0-105.0% at release, may be 90.0-110.0% in shelf-life specs if justified by stability results.

Related compounds: need limits on specified (identified and unidentified), unspecified (individual unknowns) and total related compounds. Limits must be suitably qualified.

Limits may be in S specs only, but only if there is no significant degradation observed in stability studies. Otherwise, need R limits which are tighter than S limits.

Page 25: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201225 |

Related compoundsRelated compounds

Qualification of limits: adopt limit QT, or qualify:

If a limit refers to a significant metabolite, it is considered qualified (confirm it is a metabolite, e.g. WHOPAR, EPAR, SmPC).

Level used in safety studies and/or clinical studies (ICH Q3B)

Literature i.e. ORC limits for specified related compounds are considered qualified; an unspecified/unknown limit in a monograph is not qualified.

Limit is similar to levels found in unstressed innovator product.

An enantiomer is excluded from ICH ITs and QTs (Q6A)

Page 26: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201226 |

Related compoundsRelated compounds

Note that unlike the API impurities, the FPP specified related compounds are degradants. Therefore if the means of qualification are inadequate, there is an additional consideration: reducing the degradant to below the QT.

A more protective container closure system may be investigated.

Watch for organic solvents used as granulating fluids (e.g. ethanol, isopropyl alcohol). Such solvents require a limit in the specifications (no skip testing, no justification for removal of test).

Page 27: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201227 |

Specification Parameters Microbial limits (solid orals)

Specification Parameters Microbial limits (solid orals)

Microbial limits test: a general test is required for solid orals unless justified by the submission of acceptable results for 5 production batches. If justified, skip test parameters should be in the specs: At minimum every 10th batch, at least one batch annually [R], and at release and shelf-life [S].

PhEur limits are generally acceptable: 5.1.4

Generally: include limit on total count of aerobic microorganisms, total count of yeast and molds, and absence of objectionable bacteria (e.g. E. coli). (Q6A)

Page 28: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201228 |

Specification ParametersUniformity of Dosage Units

Specification ParametersUniformity of Dosage Units

PQP requirements are newly harmonized with the PhInt:

Mass uniformity: for the API(s) present at 5 mg and 5% of the weight of the dosage unit, a test and limit for weight variation may be established in lieu of content uniformity testing;

Content uniformity: a test and limit for content uniformity is required for each API present in the FPP at < 5 mg or < 5% of the weight of the dosage unit

Criteria for application as above, otherwise, the ICH PDG harmonized text is used, i.e. limits e.g. AV NMT 15%.

Page 29: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201229 |

Specification ParametersUniformity of dosage units – scored tablets

Specification ParametersUniformity of dosage units – scored tablets

Uniformity of split portions: content uniformity requirement applies to tablets containing < 5mg or 5% of API per portion. What this effectively means: e.g. for a single breakline, tablets must be 10 mg or more for weight uniformity testing.

Page 30: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201230 |

Specification ParametersDissolution

Specification ParametersDissolution

Dissolution is considered product-specific. The method and limits should be appropriate for the proposed product. Surfactant use should be exceptional and appropriate.

Dissolution specs at release and shelf-life should be identical. It is useful to have the parameters (medium, apparatus, speed) in specs.

Some accepted specifications can be checked e.g. FDA site “Dissolution Methods for Drug Products” www.accessdata.fda.gov/scripts/cder/dissolution/

Careful consideration is required for dissolution specifications when a biowaiver was accepted (see “BE considerations for quality” talk).

Page 31: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201231 |

Specification ParametersDissolution

Specification ParametersDissolution

The limits should be expressed as “Q”, which also implies three stage testing as per harmonized texts. Ideally the stages are expressed in the specs (i.e. S1 all individual values Q+5%)

There should be a discussion if the time is > 45 minutes.

It should be ascertained that the dissolution limits are not overly wide, compared to the actual results (even for an ORC limit).

Especially for a modified release tablet, the method should be demonstrated to be discriminatory (sensitive to changes e.g. qualitative and/or quantitative difference in excipients, API particle size, process parameters or have different in-process test specifications for hardness, coating thickness etc.

Page 32: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201232 |

Specification ParametersDissolution

Specification ParametersDissolution

ICH Q6A decision trees 7(1) to 7 (3) can be used to assess the proposed dissolution criteria, however:

For considering accepting DT in place of dissolution: all the considerations should be carefully assessed (not just highly soluble and rapidly dissolving: accepted rarely and only with significant supporting development data – including when DT is more discriminating or has a demonstrated relationship to dissolution, robustness of the formulation/manufacturing process have been demonstrated wrt DT, etc.)

Some terms are not in agreement with established definitions, e.g. rapidly dissolving (80% in 15 min vs 85% in 30 min)

Page 33: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201233 |

Specification ParametersDissolution

Specification ParametersDissolution

Additional considerations are required when there is a BCS-based biowaiver (see BE considerations for Q assessment talk):

BCS Class 1 (e.g. emtricitabine, stavudine, zidovudine, levofloxacin, ofloxacin): The test and comparator products must be at least rapidly dissolving. (NLT 85% in 30 minutes)

BCS Class 3 (e.g. abacavir sulfate, lamivudine, ethambutol, isoniazid, pyrazinamide):The test and comparator products must be very rapidly dissolving (NLT 85% in 15 minutes).

Dissolution limits must meet the biowaiver requirements.

Page 34: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201234 |

Specification ParametersWater

Specification ParametersWater

Water content should be included in specs when appropriate. Specs may be justified by data on the effects of hydration or absorption on the FPP. Q6A

LOD may be considered adequate, but a water test (i.e. specific detection procedure such as Karl Fischer titration) is preferred.

If a product is to be stored in semi-permeable blisters (i.e. not Al/Al), then water should be included in stability specs.

Page 35: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201235 |

Dosage form – specific testsfor specific solid oral dosage forms

Dosage form – specific testsfor specific solid oral dosage forms

Chewable tablets: hardness and friabilityare critical (Q6A)

Effervescent tablets: it is critical to control moisture throughout manufacture and storage

Dispersible tablets: DT (NMT 3 min), fineness of dispersion (a type of palatability test)

Page 36: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201236 |

Dosage form – specific testsDosage form – specific tests

Scored tablets:

Q: When might you require breakability in the release specs?

A: When a score has been added but no scored batch has been manufactured. The test may be removed once uniformity of split portions has been ascertained.

Q: When might you require breakability in the stability specs?

A: When there is known to be significant change in tablet hardness during storage. [See EMA Quality of Medicines Q&A document]

Page 37: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201237 |

Unnecessary tests in specificationsUnnecessary tests in specifications

In-process tests: used for the purpose of adjusting process parameters within an operating range; e.g. hardness, friability (see exception for chewable tabs), individual tablet weight

Impurities from the API synthesis which are not degradants; not normally controlled in FPP testing, and not included in the total impurities limit. Note that the enantiomer should be controlled. (Q6A)

Shelf-life specifications do not need to include tests that are not stability-indicating, such as identity and content uniformity.

Redundant tests: e.g. MU when CU is required and included

Page 38: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201238 |

Example specificationsExample specifications

See separate handout. Full result slides will be provided after the workshop.

Page 39: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201239 |

Review tipsReview tips

Specifications should have been developed based on the results of the primary batches, primarily the biolot.

A comparison of the specs to the biolot results should result in questions or further considerations when the specs are much wider than, or are not representative of, the results.

Updated specs should always be compared to the previous version submitted, or at minimum the change history should be reviewed. The result of the comparison must be in the report, with a discussion of solicited and unsolicited changes.

Page 40: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201240 |

Review tipsReview tips

Scanning specs into reports:

Always include page tops (including e.g. “page 1 of 5” and specifications codes/versions)

Always include page bottoms (so it is clear the full specs were included)

Always include the final page, even if “only” footnotes.

The footnotes and related compound names are a critical part of specs! (Names should be conducive to knowing structure, ie EP impurity A or 6 -ethinyl estradiol)

Page 41: Lynda Paleshnuik | January 2012 1 |1 | Quality Workshop Copenhagen – January 2012 Assessing specifications: FPP (solid orals)

Lynda Paleshnuik | January 201241 |