25
Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Embed Size (px)

Citation preview

Page 1: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Luxline PlusTriphosphor Lamps / TIM1 Phase Out

(TIM = Tertiary Implementation Measure)

Page 2: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

What is being phased out?

Page 3: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

10-04-233

1st stage starting April 13th 2010

• T8 and T5 lamps have to fullfill lm/W efficiency criterias• T8 and T5 lamps need to have an CRI index >80• Product information has to be made public for all LFL lamps

=> Ban of Standard Halophosphor Fluorescent Lamps T8T8 HALO-PHOSPHOR

T8 TRIPHOSPHOR

XT8 (26 mm Ø) T5 (16 mm Ø) High Efficiency T5 (16 mm Ø) High Output

Nominal wattage

(W)

Rated luminous efficacy (lm/W),

100 h initial value

Nominal wattage (W)

Rated luminous efficacy (lm/W), 100h initial value

Nominal wattage

(W)

Rated luminous efficacy (lm/W),

100 h initial value

15 63 14 86 24 73

18 75 21 90 39 79

25 76 28 93 49 88

30 80 35 94 54 82

36 93 80 77

38 87

58 90

70 89

Rated minimum efficacy values for T8 and T5 Lamps

Linear Fluorescent

TIM1 – Phase-out Halophsophor T8 & Minimum efficiencies

Page 4: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

10-04-234

1st stage starting April 13th 2010 • T5 and T9 Circline have to fullfill lm/W efficiency criterias• T5 and T9 Circline need to have an CRI index >80

=> Ban of Standard Halophosphor Fluorescent Lamp T9 CirclineT9 HALO-PHOSPHORX

T9 Circular (29 mm Ø) Base G10q T5 Circular (16 mm Ø) Base2GX13

Nominal wattage (W)

Rated luminous efficacy (lm/W), 100 h initial value

Nominal wattage (W)

Rated luminous efficacy (lm/W), 100 h initial value

22 52 22 77

32 64 40 78

40 70 55 75

60 60 60 80

Rated minimum efficacy values for T9 and T5 circular lamps

Linear Fluorescent

TIM1 – Phase-out Halophsophor Circline & Minimum efficiencies

Page 5: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

What is exempt?

Page 6: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

10-04-236

Double capped fluorescent lamps having:

• a diameter of 7 mm (T2) and less,

• a diameter of 16 mm (T5) and lamp power P ≤ 13W or P > 80W, (Short T5 exempt)

• a diameter of 38 mm (T12), lamp cap G-13 Medium BiPin base, +/-5m (+magenta, -green) color compensating filter value limit (cc). CIE coordinates x=0.330 y=0.335 and x=0.415 y=0.377, (T12 Halo = April 2012)

• a diameter of 38 mm (T12) and equipped with an external ignition strip

•Special application T8 Halophsophor (i.e Petcare, Gourmet, Coloured)

Linear Fluorescent

TIM1 – Phase-out – Exempted Fluorescent Lamps

Page 7: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

What alternative lamps will be available?

Page 8: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

8

Linear Fluorescent

T8 Luxline Plus – Halophosphor to Triphosphor / Eco cross-reference

T8 Halo Phase Out Leaflet Luxline Plus Brochure Luxline Plus Triphosphor Guide Sylvania Luxline Plus Pens

Support Tools

Page 9: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

04/10/239

T5- Halophosphor Lamps

Linear Fluorescent

TIM1 – Phase-out – Banned? Not Banned?

T5 Halophosphor0000002 F 4W T5 35-535 Not Banned0000003 F 4W T5 33-640 Not Banned0000001 F 4W T5 54-765 Not Banned0000014 F 6W T5 29-530 Not Banned0000012 F 6W T5 35-535 Not Banned0000013 F 6W T5 33-640 Not Banned0000011 F 6W T5 54-765 Not Banned0000382 F 8W T5 29-530 Not Banned0000020 F 8W T5 35-535 Not Banned0000021 F 8W T5 33-640 Not Banned 0002738 F 8W T5 8400000019 F 8W T5 54-765 Not Banned0000032 F 13W T5 29-530 Not Banned0000030 F 13W T5 35-535 Not Banned0000031 F 13W T5 33-640 Not Banned0000029 F 13W T5 54-765 Not Banned

0001901 F 6 W / 29-530 Emergency Not Banned0001900 F 6 W / 33-640 Emergency Not Banned0001910 F 6 W / 33-640 Emergency Not Banned 0001911 F 6W T5 840 Emergency0001902 F 6 W / 54-765 Emergency Not Banned0001905 F 8 W / 33-640 Emergency Not Banned 0001913 F 8W T5 840 Emergency0001912 F 8 W / 33-640 Emergency Not Banned 0001913 F 8W T5 840 Emergency0001908 F 8 W / 54-765 Emergency Not Banned

AvailabilityAlternative Triphosphor

DescriptionItem

Alternative Triphsophor

Code

Affected April 2010

Page 10: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

04/10/2310

T8- Halophosphor Lamps 14W-25W

Linear Fluorescent

TIM1 – Phase-out – Banned? Not Banned?

T8 Halophosphor0000040 F 14W T8 29-530 answer still expected0000039 F 14W T8 33-640 answer still expected0000037 F 14W T8 54-765 answer still expected0000065 F 15W T8 29-530 Banned 0001853 F 15W T8 830 April 20100000063 F 15W T8 35-535 Banned0000064 F 15W T8 33-640 Banned 0000567 F 15W T8 840 April 20100000062 F 15W T8 54-765 Banned 0000947 F 15W T8 860 April 20100000861 F 16W T8 29-530 Banned 0000862 F 16W T8 830 April 20100000868 F 16W T8 35-535 Banned0000860 F 16W T8 33-640 Banned 0000863 F 16W T8 840 April 20100001409 F 18W T8 29-530 Banned 0001501 F 18W T8 830 April 20100001408 F 18W T8 35-535 Banned 0000580 F 18W T8 835 April 20100001406 F 18W T8 33-640 Banned 0001500 F 18W T8 840 April 20100001407 F 18W T8 25-740 Banned 0001500 F 18W T8 840 April 20100001410 F 18W T8 54-765 Banned 0001502 F 18W T8 860 April 20100001768 F 25W T8 28" 33-640 Banned 0001772 F25W T8 28" 840 April 20100001767 F 25W T8 28" 54-765 Banned 0001773 F25W T8 28" 865 April 20100001086 F 25W T8 30" 29-530 Banned 0001774 F25W T8 30" 830 April 20100001085 F 25W T8 30" 33-640 Banned 0001775 F25W T8 30" 865 April 20100001770 F 25W T8 33" 33-640 Banned 0001776 F25W T8 33" 840 April 20100001769 F 25W T8 33" 54-765 Banned 0001777 F25W T8 33" 865 April 2010

Expected to continue as HaloExpected to continue as HaloExpected to continue as Halo

NO ALTERNATIVE

NO ALTERNATIVE

AvailabilityAlternative descriptionItem Affected April 2010 Alternative Code

Page 11: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

T8- Halophosphor Lamps 30W-70W

Linear Fluorescent

TIM1 – Phase-out – Banned? Not Banned?

0000145 F 30W T8 29-530 Banned 0001079 F 30W T8 830 Now0000143 F 30W T8 35-535 Banned 0001077 F 30W T8 835 Now0000144 F 30W T8 33-640 Banned 0001080 F 30W T8 840 Now0000142 F 30W T8 54-765 Banned 0001078 F 30W T8 860 Now0001419 F 36W T8 29-530 Banned 0001511 F 36W T8 830 Now0001418 F 36W T8 35-535 Banned 0000578 F 36W T8 835 Now0001416 F 36W T8 33-640 Banned 0001510 F 36W T8 840 Now0001417 F 36W T8 25-740 Banned 0001510 F 36W T8 840 Now0001420 F 36W T8 54-765 Banned 0001512 F 36W T8 860 Now0001508 F 36W T8 1M 25-740 Not Banned 0001504 F 36W T8 1M 840 Now0001784 F 38W T8 25-740 Banned 0001520 F 38W T8 840 Now0001439 F 58W T8 29-530 Banned 0001531 F 58W T8 830 Now0001438 F 58W T8 35-535 Banned 0001394 F 58W T8 835 Now0001436 F 58W T8 33-640 Banned 0001530 F 58W T8 840 Now0001437 F 58W T8 25-740 Banned 0001530 F 58W T8 840 Now0001440 F 58W T8 54-765 Banned 0001532 F 58W T8 860 Now0001092 F 70W T8 29-530 Banned 0001093 F 70W T8 830 Now0001091 F 70W T8 35-535 Banned 0000581 F 70W T8 835 Now0001090 F 70W T8 33-640 Banned 0001094 F 70W T8 840 Now

AvailabilityAlternative descriptionItem Affected April 2010 Alternative Code

Page 12: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Circline Halophosphor Lamps

Linear Fluorescent

TIM1 – Phase-out – Banned? Not Banned?

T9 Circline0000475 FC 22W T9 29-530 Banned 0001960 FC 22W T9 8300000474 FC 22W T9 33-640 Banned 0001961 FC 22W T9 8400000478 FC 22W T9 25-740 Banned 0001961 FC 22W T9 8400000472 FC 22W T9 54-765 Banned 0001962 FC 22W T9 8650000485 FC 32W T9 29-530 Banned 0001963 FC 32W T9 8300000484 FC 32W T9 33-640 Banned 0001964 FC 32W T9 8400000488 FC 32W T9 25-740 Banned 0001964 FC 32W T9 8400000482 FC 32W T9 54-765 Banned 0001965 FC 32W T9 8650000494 FC 40W T9 29-530 Banned 0001966 FC 40W T9 8300000493 FC 40W T9 33-640 Banned 0001967 FC 40W T9 8400000497 FC 40W T9 25-740 Banned 0001967 FC 40W T9 8400000491 FC 40W T9 54-765 Banned 0001968 FC 40W T9 8650001065 FC 60W T9 29-530 Banned

Availability

NO ALTERNATIVE

Alternative descriptionItem Affected April 2010 Alternative Code

Page 13: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

The benefits of Triphosphor

Page 14: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Linear Fluorescent

Luxline Plus - Range

So much brighter offers a higher light output with low loss of lumen maintenance during its long life.

Stellar performance offers increased luminaire efficiency (5 to 10%) over T8 Standard lamps.

Improved CRI better Colour Rendering Index – in excess of Ra 80. particularly beneficial in areas where people work or stay for lengthy periods.

Longer lasting up to 24,000 hours. twice as long as a T8 Standard lamp. This means reduced capital expenditure and less maintenance work and costs.

Environmentally friendly Low mercury content, less energy usage, longer Backwards compatible - is fully compatible with all T8 Standard circuitry, ballasts and fixtures.

Page 15: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

• High light output

• High lumen maintenance – 85% over life

• High colour rendering – Ra85+

• Colour temperature 2700,3000, 3500, 4000 & 6000 K

T5

• Luxline Plus FHE G5 for Low Brightness louvre recessed and surface-mounted - 14, 21, 28 & 35 W

• Luxline Plus FHO G5 for Indirect luminaires 24, 39, 49 & 54 W

• Average rated life = 24000 hours

T8

• Average rated life 20 000 hrs

Linear Fluorescent

Luxline Plus - Range

Page 16: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

16

Linear Fluorescent

T8 Luxline Plus – standard and special length

–Shops, departments, stores, offices, schools–Hotels, conference centres, restaurants–Workshops, warehouses ,laboratories etc

18W

590mm

36W

1200mm

58W

1500mm

70W

1764mm

15W

438mm

30W

895mm

38W

1047mm

Colour rendering : Ra 80-89/Class 1B

20,000 hours lifetime with warm start electronic ballast

Applications:

Page 17: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

17

Linear Fluorescent

T5 Luxline Plus – FHE & FHO

FHE / FHO

14W / 24W

549mm

FHE / FHO

21W / 39W

849mm

FHE / FHO

28W / 54W

1149mm

FHE / FHO

35W /49W, 80W

1449mm

– Shops, departments, stores, offices, schools– Hotels, conference centres, restaurants– laboratories etc

Applications:

Colour rendering : Ra 80-89/Class 1B

20,000 hours lifetime with warm start electronic ballast

Page 18: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

• Luxline Plus FHE G5 for Low Brightness louvre recessed and surface-mounted

• Up to 104lm/W

• 14, 21, 28 & 35 W

• Colour temperature 2700, 3000, 3500, 4000 & 6000 K

• Burning position horizontal / stamped side down/same end in twin lamp luminaires

• Average rated life 24 000 hrs

Linear Fluorescent

T5 Luxline Plus – FHE – High Efficiency

Page 19: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

• Luxline Plus FHO G5 for Indirect luminaires

• Up to 7000lm

• 24, 39, 49 & 54 W

• Colour temperature 2700, 3000, 3500, 4000 & 6000 K

• Burning position horizontal / stamped side down/same end in twin lamp luminaires

• Average rated life 24 000 hrs

Linear Fluorescent

T5 Luxline Plus – FHO – High Output

Page 20: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Luxline ECO

Page 21: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Luxline Eco

– What is Luxline ECO?– A high performance range of energy saving T8 fluorescent lamps (>10% energy

saving)– 32W replaces 36W– 51W replaces 58W

– Retrofit with existing T8 lamps– Operates on both HF* and EM control gear– Lifetime up to 15k hrs (standard halo = 14k. Tri = 20k)– Range covering key colours 830, 840 and 865

– Why are we introducing Luxline ECO?– Market potential – The energy reduction results in electricity cost reduction and

improved environmental credentials – both major market drivers– Our Vision – Supports our vision of providing innovative, sustainable solutions

– Applications– Replacement of T8 and T12 lamps, education buildings, shops, offices, public

buildings, corridors, factories, warehouses

Page 22: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Key Features and Benefits

– Simple - Retrofit with existing T8 and T12 halo and triphosphor– Energy saving and similar light output to T8 and T12 halophosphor

– Energy saving and small drop in light output compared with T8 and T12 triphosphor (approx 10%)

– Saves money and the environment

– Easy to switch, just change the lamps

– Rapid payback– Energy savings allow investment to be recouped within 1 year

– Long Life – 15,000 hours on EM gear c/w 14,000 hrs for halophosphate

– Reduces maintenance costs and hassle compared with halophosphor lamps

– Good Colour Quality– By using triphosphor technology, colour rendering is very good (CRI>80)

– Makes the objects and the space look natural

– Low mercury (3.3mg)– Reduced amount of this hazerdous material

Please note these lamps are more suseptible to ambient temperature changes. Further technical information is being developed.

Page 23: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Luxline Supercolour

Page 24: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Summary

– What is Luxline Plus SuperColour?– A high performance range of very high colour rendering linear fluorescent

lamps (CRI Group 1A)(CRI>90)– Colour 940 (4000K) in 18W, 36W and 58W

– Retrofit with existing T8 lamps– Operates on both HF and EM control gear– Lifetime up to 20k hrs (standard halo = 14k)

– Why are we introducing Luxline Plus SuperColour?– Market potential – There is an increasing drive towards high colour quality

(natural) lighting for both standard as well as specialist applications– Range Completion – As the interest grows from standard applications, we

need to have product available

– Applications– Replacement of T8 and T12 lamps in education buildings, shops, offices,

public buildings, factories, specialist applications, healthcare (diagnosis), printing, colour critical processes

Available NowAvailable Now

Page 25: Luxline Plus Triphosphor Lamps / TIM1 Phase Out (TIM = Tertiary Implementation Measure)

Key Features and Benefits

– Excellent Colour Quality– CRI >90 C/W >80 for triphosphor and >60 for halo

– Makes the ambience appear more natural and true.

– Renders objects in the space more naturally

– Merchandise in store looks more appealing

– Simple - Retrofit with existing T8 and T12 halo and triphosphor– Easy to switch, just change the lamps

– Long Life – 20,000 hours on EM gear (same as triphosphor) c/w 14,000 hrs for halophosphate

– Reduces maintenance costs and hassle compared with halophosphor lamps

– Low mercury (3.3mg c/w 6-8mg for halophosphate)– Reduced amount of this hazerdous material

Please note – I am investigating the feasability of these lamps for use in Hospital Areas for the Diagnosis of Cyanosis. To be confirmed.