2
1.85V/cell 1.80V/cell 1.75V/cell 1.70V/cell 1.65V/cell 1.60V/cell 5min 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 20min 0 0 Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 5min 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 20min 0 0 Constant Power Discharge (Watts/cell) at 25 C (77 F ) F.V/Time 1.85V/cell 1.80V/cell 1.75V/cell 1.70V/cell 1.65V/cell 1.60V/cell LP6-3.2 (6V3.2AH) Germany t est ed 9 Nominal Voltage Approx Weight Max. Discharge Current Internal Resistance Operating Temp.Range Nominal Operating Temp. Range Self Discharge Terminal Container Material 6V LP series batteries may be stored for up to 6 months 0 0 at 25 C(77 F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Specification Applications Cycle Use Standby Use Initial Charging Current less than 0.96A.Voltage 0 0 0 7.2V~7.5V at 25 C(77 F)Temp. Coefficient -15mV/ C No limit on Initial Charging Current Voltage 0 0 0 6.75V~6.9V at 25 C(77 F)Temp. Coefficient -10mV/ C Capacity affected by Temperature 103% 100% 86% o o 40 C (104 F) o o 25 C ( 77 F) o o 0C ( 32 F) Nominal Capacity(20HR) 3.2AH Dimensions Length Width Container Height Total Height (with Terminal) Rated Capacity 0 0 (20hr ,1.80V/cell,25 C/77 F) 0 0 (10hr,1.80V/cell,25 C/77 F) 0 0 (5hr,1.75V/cell,25 C/77 F) 0 0 (3hr,1.75V/cell,25 C/77 F) ABS T1 48A (5s) Approx 28m 0 0 25 3 C (77 5 F ) All purpose Uninterruptable Power Supply (UPS) Electric Power System (EPS) Emergency backup power supply Emergency light Railway signal Aircraft signal Alarm and security system Electronic apparatus and equipment Communication power supply DC power supply Auto control system Approx 0.67 kg (1.48lbs) LP SERIES-General Purpose 0 0 (1hr,1.60V/cell,25 C/77 F) 134 2mm (5.28 inches) 34 1mm (1.34 inches) 60 1mm (2.36 inches) 66 1mm (2.60 inches) 3.20 AH/0.160A 2.98 AH/0.298A 2.69 AH/0.538A 2.35 AH/0.783A 1.94 AH/1.94A 0 0 Discharge : -15 50 C (5 122 F) 0 0 Charge : 0 40 C (32 104 F) 0 0 Storage : -15 40 C (5 104 F) 6.14 4.28 3.53 3.06 2.46 1.89 1.55 0.944 0.719 0.591 0.502 0.435 0.345 0.287 0.158 7.55 5.11 4.10 3.47 2.72 2.06 1.66 1.00 0.756 0.622 0.524 0.454 0.358 0.298 0.160 8.95 5.78 4.52 3.77 2.91 2.19 1.75 1.05 0.783 0.641 0.538 0.465 0.368 0.303 0.162 10.2 6.37 4.89 4.05 3.05 2.27 1.82 1.09 0.809 0.657 0.551 0.476 0.374 0.308 0.164 11.2 6.85 5.17 4.25 3.18 2.36 1.90 1.12 0.829 0.670 0.563 0.485 0.380 0.313 0.167 11.8 7.14 5.39 4.39 3.27 2.41 1.94 1.16 0.849 0.687 0.575 0.495 0.388 0.318 0.168 11.6 8.16 6.79 5.93 4.79 3.71 3.04 1.87 1.43 1.18 1.00 0.872 0.695 0.579 0.320 14.1 9.64 7.81 6.66 5.27 4.01 3.26 1.98 1.49 1.23 1.04 0.905 0.716 0.596 0.322 16.5 10.8 8.53 7.20 5.59 4.24 3.41 2.05 1.54 1.26 1.06 0.921 0.731 0.604 0.322 18.5 11.8 9.15 7.67 5.83 4.38 3.53 2.12 1.58 1.29 1.08 0.938 0.738 0.610 0.326 20.1 12.5 9.56 7.97 6.03 4.52 3.66 2.17 1.61 1.31 1.10 0.952 0.746 0.616 0.329 20.8 12.9 9.86 8.13 6.13 4.58 3.71 2.22 1.64 1.33 1.12 0.966 0.758 0.623 0.330 Specifications subject to change without notice. Ω MH 48553

LP6-3.2 (6V3.2AH) - landportbv.com · LP6-3.2 (6V3.2AH) Germany 9 tested Nominal Voltage Approx Weight Max. Discharge Current Internal Resistance Operating Temp.Range Nominal Operating

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LP6-3.2 (6V3.2AH) - landportbv.com · LP6-3.2 (6V3.2AH) Germany 9 tested Nominal Voltage Approx Weight Max. Discharge Current Internal Resistance Operating Temp.Range Nominal Operating

1.85V/cell1.80V/cell1.75V/cell1.70V/cell1.65V/cell1.60V/cell

5min 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h20min

0 0Constant Current Discharge (Amperes) at 25 C (77 F )F.V/Time

5min 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h20min

0 0Constant Power Discharge (Watts/cell) at 25 C (77 F )F.V/Time1.85V/cell1.80V/cell1.75V/cell1.70V/cell1.65V/cell1.60V/cell

LP6-3.2 (6V3.2AH)

Germanyt ested9

Nominal Voltage

Approx Weight

Max. Discharge CurrentInternal Resistance

Operating Temp.Range

Nominal Operating Temp. Range

Self Discharge

Terminal

Container Material

6V

LP series batteries may be stored for up to 6 months0 0at 25 C(77 F) and then a freshening charge is required.

For higher temperatures the time interval will be shorter.

Specification

Applications

Cycle Use

Standby Use

Initial Charging Current less than 0.96A.Voltage 0 0 07.2V~7.5V at 25 C(77 F)Temp. Coefficient -15mV/ C

No limit on Initial Charging Current Voltage 0 0 06.75V~6.9V at 25 C(77 F)Temp. Coefficient -10mV/ C

Capacity affected by Temperature

103%100%86%

o o 40 C (104 F)o o 25 C ( 77 F)

o o 0 C ( 32 F)

Nominal Capacity(20HR) 3.2AH

Dimensions

LengthWidthContainer HeightTotal Height (with Terminal)

Rated Capacity

0 0(20hr ,1.80V/cell,25 C/77 F)0 0(10hr,1.80V/cell,25 C/77 F)0 0(5hr,1.75V/cell,25 C/77 F)0 0(3hr,1.75V/cell,25 C/77 F)

ABST1

48A (5s)Approx 28m

0 025 3 C (77 5 F )

All purpose

Uninterruptable Power Supply (UPS)

Electric Power System (EPS)

Emergency backup power supply

Emergency light

Railway signal

Aircraft signal

Alarm and security system

Electronic apparatus and equipment

Communication power supply

DC power supply

Auto control system

Approx 0.67 kg (1.48lbs)

LP SERIES-General Purpose

0 0(1hr,1.60V/cell,25 C/77 F)

134 2mm (5.28 inches)34 1mm (1.34 inches) 60 1mm (2.36 inches)66 1mm (2.60 inches)

3.20 AH/0.160A2.98 AH/0.298A2.69 AH/0.538A2.35 AH/0.783A1.94 AH/1.94A

0 0Discharge : -15 50 C (5 122 F)00Charge : 0 40 C (32 104 F)

0 0Storage : -15 40 C (5 104 F)

6.14 4.28 3.53 3.06 2.46 1.89 1.55 0.944 0.719 0.591 0.502 0.435 0.345 0.287 0.1587.55 5.11 4.10 3.47 2.72 2.06 1.66 1.00 0.756 0.622 0.524 0.454 0.358 0.298 0.1608.95 5.78 4.52 3.77 2.91 2.19 1.75 1.05 0.783 0.641 0.538 0.465 0.368 0.303 0.16210.2 6.37 4.89 4.05 3.05 2.27 1.82 1.09 0.809 0.657 0.551 0.476 0.374 0.308 0.16411.2 6.85 5.17 4.25 3.18 2.36 1.90 1.12 0.829 0.670 0.563 0.485 0.380 0.313 0.16711.8 7.14 5.39 4.39 3.27 2.41 1.94 1.16 0.849 0.687 0.575 0.495 0.388 0.318 0.168

11.6 8.16 6.79 5.93 4.79 3.71 3.04 1.87 1.43 1.18 1.00 0.872 0.695 0.579 0.32014.1 9.64 7.81 6.66 5.27 4.01 3.26 1.98 1.49 1.23 1.04 0.905 0.716 0.596 0.32216.5 10.8 8.53 7.20 5.59 4.24 3.41 2.05 1.54 1.26 1.06 0.921 0.731 0.604 0.32218.5 11.8 9.15 7.67 5.83 4.38 3.53 2.12 1.58 1.29 1.08 0.938 0.738 0.610 0.32620.1 12.5 9.56 7.97 6.03 4.52 3.66 2.17 1.61 1.31 1.10 0.952 0.746 0.616 0.32920.8 12.9 9.86 8.13 6.13 4.58 3.71 2.22 1.64 1.33 1.12 0.966 0.758 0.623 0.330

Specifications subject to change without notice.

Ω

MH 48553

Page 2: LP6-3.2 (6V3.2AH) - landportbv.com · LP6-3.2 (6V3.2AH) Germany 9 tested Nominal Voltage Approx Weight Max. Discharge Current Internal Resistance Operating Temp.Range Nominal Operating

Dimensions

T1 TerminalUnit: mm [inches]

134 1

601

661

341

3.2 [0.126]

6.35 [0.25]

0.8

[0.0

31]

4.75

[0.1

87]

Storage Time(Months)

Rema

ining

Cap

acity

(%)

8 10 120

4 6

60

80

100

2

20

40

025 C

030 C040 C

010 C A

B

C

0.5

Battery temperature

1

2

34568

10

Charging voltage :2.25V/cell

2068

0C3086

40104

50122 OF

Life e

xpec

tancy

(year)

Testing conditionDischarging:current 0.17CA (FV 1.7V/cell);Charging:current 0.25C max, voltage 2.45V/cell;Charging volume:125% of discharged capacity.

Cap

city

(%)

120

100

80

60

40

20

00 200 400 600 800 1000 1200

Number of Cycles

Ambient Termperature:o o25 C (77 F)

100%DOD

50%DOD

30%DOD

-20 -10 0 10 20 30 40 500

20

40

60

80

100

120

0.05CA

0.1CA

0.2CA

1.0CA

2.0CA 3.0CA

0Temperature( C)

Capa

city

%

No supplementary charge required(Carry out supplementary charge before use if 100% capacity is required.)

Supplementary charge required before use.Optional charging way as below:1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell.2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.3.Charged for 8~10hours at limted current 0.05CA .

Supplementary charge may often fail to recover the capacity.The battery should never be left standing till this is reached.

A

B

C

Cycle Life in Relation to Depth of Discharge Self Discharge Characteristics

Effect of Temperature on Long Term Float Life

Float Charging Characteristics

0 8 16 2012 24 28 32 36 40

6.0

6.5

7.0

7.5

(XCA)%

ChargeVolume

Charging Current

After 100% Discharge

Charge Voltage(Constant 2.25v/cell)

Charging Current5.5

4

0.10

0.15

0.20

0.25

0.05

00102030

5040

60708090

100

120110

Charging Voltage

(V)

Charging Time(hours)

00.10CA-2.25V/cell temperature25 C

After 50% Discharge

Charged Volume

Temperature Effects in Relation to Battery Capacity

0.05C0.093C0.207C

0.4C

0.628C1C

2C3C

101 2 4 6 20 40 60 2 4 6 8 10

HMin

8 20

6.5

6.0

5.5

5.0

4.5

4.0

V

6VBattery 0 0Temperature:25 C(77F)

Term

inal V

oltag

e(V)

Discharge Time

Discharge Characteristics