®/* Trademarks of Kimberly-Clark Worldwide, Inc., or its affiliates. © 2010 KCWW. Publication code: ID 4565.01 GB 03.10
Da
ta
Pa
ck
KIMTECH PURE* G5 STERLING* Nitrile Gloves
Engineered for Protection. Designed for Comfort.
Vital process protection and comfort.
KIMTECH PURE* G5 STERLING* Nitrile Gloves
KIMTECH PURE* G5 STERLING* Nitrile Gloves offer Improved Performance, Added Value and are Better for the Environment.
• RecommendedforISOClass5orhighercleanroom environments
• Containnonaturalrubberlatexreducingthepotential forTYPEIglove-associatedreactions
• Staticdissipativeinuse
• Safehandlingofobjectsduetoimprovedand consistentgrip
• Double-baggedwithcaseliner
• CertificateofAnalysis(byLot)availableonline
• TrendDataavailableonlinetodemonstrateproduct qualityovertime
Improved PerformanceOurSTERLING* Nitrile manufacturingprocessboosts theglove’stensilestrength(theforcerequiredtobreakthroughtheglove) to increase itsbarrierprotection.Theprocessalsoallowsareductioninglovethickness,solessforceis requiredtostretchthematerial.Theresult isa latex-freeglovewiththedexterityandsensitivityoflatex.
Added ValueThe STERLING* Nitrile Gloves can reduce the waste without sacrificing strength, comfort or protection. The thinner material of the glove and its improved tensilestrengthenhance thewearer’scomfort. Improved performance means a better value for you and your business.
Better For The EnvironmentReduced glove thickness requires less raw materials inproduction which can significantly reduce your waste.Therearemoreglovesperpackandsolessstoragespaceisrequired.
TYPICAL INDUSTRIES
•Semiconductor •MedicalDevice
•FlatPanelDisplay •Pharmaceutical
•DiskDriveManufacturing •Electronics
0123
EN374-1:2003
EN374-2:2003
LEVEL 2
KIMTECH PURE* G5 STERLING* Nitrile GlovesProduct Specifications•Syntheticnitrile1polymer(AcrylonitrileButadiene)
•Containsnonaturalrubberlatex.Silicone-free
KIMTECH PURE* G5 STERLING* Nitrile Gloves
SizeandCode 30cm
6xXS 98184S 98185M 98186L 98187L+ 98188XL 98189 =1500
250x
PHYSICAL PROPERTIES (Target values) Characteristics Value Test Method
Freedomfromholes 1.5AQL EN374-1 1AQLasdefinedperISO2859-1forsamplingbyattributes
Tensile Properties Tensile Strength Ultimate Elongation-BeforeAging 42MPa,nominal 650%nominal ASTMD412andASTMD573-AfterAcceleratedAging 38MPa,nominal 550%nominal
Dimensional Measured mm Point-NominalThickness MiddleFinger 0.10 ASTMD3767andD6319 Palm 0.08 Cuff 0.07
Palm Widths-NominalWidth(mm) X-Small Small Medium Large Largeplus X-Large ASTMD3767andD6319 74 84 96 111 116 123
*TrademarkofKimberly-ClarkWorldwide,Inc.,oritsaffiliates.©2008KCWW.Publicationcode:4484.01GB10.08
www.kcprofessional.comVisitourwebsiteanddiscoverabrandnewconceptin
cleanroom:theCONTAMINOMICS*Programme– www.contaminomics.com
STATIC DISSIPATIVE IN USE
LATEX-FREE
BEADED CUFFAVAILABLE IN 30CM LENGTH
Quality Standards•ThisisaPPECategoryIIIproductclassifiedbyECCouncilDirective 89/686/EEC.ItistestedinaccordancewiththeENNormsEN420:2003
•PackagedinaISOClass5Cleanroom
•MeetsorexceedsAQLlevelof1.5forpinholes
•ManufacturedinaccordancewithQualitySystemISO9001
•DexterityClassification(EN420:2003)=5
1Nitrile is a synthetic material exhibiting many of the properties of naturalrubberlatexwhileofferingotherdistinctadvantages:comfortablefit, resistance to puncturing and abrasion without compromising dexterity or electrostatic dissipative properties.
INFORMATIONSERVICEFortechnicalenquiriespleaseemailinfofax@[email protected]
TEXTURED FINGERTIPS
POWDER-FREE
EXCELLENT DEXTERITY & TACTILE SENSITIVITY
KIMTECH PURE*G5 Sterling Nitrile Powder Free Cleanroom GloveCatalog Numbers: 98184, 98185, 98186, 98187, 98188, 98189
Lot #: 960190 Total Cases per Lot: 671Batches: SM900101X to SM903101X Date of Manufacture: Jan-09
Elongation (%) Tensile (MPa)Watertight Dimensions Minor Major Pre Aging Pre Aging
Sample Size: 2065 384 2065 2065 244 244AQL Level: 1.5 2.5 4.0 2.5 2.5 2.5
Failures Allowed per AQL: 48 14 118 79 9 8Failures: 0 0 0 1 0 0
Inspection Results: Accept Accept Accept Accept Accept AcceptAverages: 630 36.6
Test Methods: Watertight ASTM D 5151, Elongation and Tensile ASTM D 412
Particle Standard AverageSize (µm) Min Max Deviation Particles/cm²0.5 - 1.0 511 1383 224 957
Certificate of Analysis
Product Description:
Physical Test DataVisual Defects
Particle Test Data
0.5 - 1.0 511 1383 224 9571.0 - 2.0 16 141 33 802.0 - 5.0 3 34 8 16
5.0 - 10.0 0 3 1 110.0 - 20.0 0 1 0 0
>20 0 0 0 0Total per Sample 530 1484 249 1055
Test Method: IEST-RP-CC005
Fluoride Chloride Nitrite Bromide Nitrate Phosphate SulfateF- Cl- N02
- Br-N03
- P04-3 S04
-2
µg/g glove <0.5 21.8 <2.5 <2.5 9.0 <5 2.1µg/cm2 <0.003 0.099 <0.016 <0.016 0.041 <0.031 0.013
Trace Element ResultsSodium Ammonium Potassium Magnesium Calcium Zinc
Na+NH4
+ K+ Mg+2 Ca+2Zn
µg/g glove 0.7 0.8 1.8 0.3 31.5 3.0µg/cm2 0.004 0.004 0.008 0.002 0.146 0.013
Test Method: IEST-RP-CC005
*Registered Trademark or Trademark of Kimberly-Clark Corporation or its affiliates. Copyright 2001 Kimberly-Clark Corp.
This document is intended for customer use only. Any disclosure, copying, distribution, or other use of this document is strictly prohibited.
Review By :
( QA Executive - SSMT )
Cations Results
Extractable Ion Test DataAnions Results
Review By :
( QA Executive - SSMT )
SA-FORM01192/0