12
9 th European Workshop on Structural Health Monitoring July 10-13, 2018, Manchester, United Kingdom Longitudinal strain monitoring of rails using distributed and discrete sensors Christian J Barker 1 , Neil A Hoult 2 and Merrina Zhang 3 1 Queen’s University, Canada, [email protected] 2 Queen’s University, Canada, [email protected] 3 National Research Council of Canada, Canada, [email protected] Abstract With one of the most extensive rail networks in the world (48,000 km of track), rail transportation is vital to Canada. Newer, more powerful locomotives hauling heavier freight at higher operating speeds are capable of producing twice the tractive effort of older locomotives. This has raised concerns regarding the risks associated with exceeding the longitudinal load carrying capacity of in-service rail support systems (e.g. bridges). There is now a growing need to investigate the longitudinal stresses that rails are being subjected to and to evaluate the potential requirement for rail rehabilitation. Past studies exploring structural health monitoring (SHM) techniques for rail infrastructure have focused on the application of discrete strain sensor technologies making it difficult to understand the rail’s full strain profile under locomotive loading. This paper introduces a series of dynamic field tests conducted to assess the suitability of both distributed and discrete sensors to measure longitudinal rail strain under locomotive braking. A distributed fibre optic sensor (FOS) based on Rayleigh backscatter in addition to electrical resistance strain gauges were used. Conclusions will be drawn as to the most applicable rail monitoring technology and future research directions will be outlined. 1.0 Introduction Railway bridges are being exposed to greater longitudinal forces than their original design intended and, consequently, are becoming a growing concern as their conditions worsen with age (1). With over 100,000 bridges, more than half predating 1920, North America’s rail network is expected to exceed its freight tonnage capacity over the next 20 years as today’s locomotives are hauling heavier freights at higher operating speeds (2). A study by Foutch et al. conducted to measure longitudinal forces in railway bridge decks under the operating limits of new locomotives at the time measured forces 30 times greater than those used to design the original structure (1). Therefore, it is imperative that condition assessment of rail infrastructure accounts for longitudinal forces so that actions may be taken to ensure these bridges are performing adequately under these increasing loads. More info about this article: http://www.ndt.net/?id=23383

Longitudinal strain monitoring of rails using distributed

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Longitudinal strain monitoring of rails using distributed

9th European Workshop on Structural Health Monitoring

July 10-13, 2018, Manchester, United Kingdom

Longitudinal strain monitoring of rails using distributed and discrete

sensors

Christian J Barker1, Neil A Hoult2 and Merrina Zhang3

1 Queen’s University, Canada, [email protected]

2 Queen’s University, Canada, [email protected]

3 National Research Council of Canada, Canada, [email protected]

Abstract

With one of the most extensive rail networks in the world (48,000 km of track), rail

transportation is vital to Canada. Newer, more powerful locomotives hauling heavier

freight at higher operating speeds are capable of producing twice the tractive effort of

older locomotives. This has raised concerns regarding the risks associated with exceeding

the longitudinal load carrying capacity of in-service rail support systems (e.g. bridges).

There is now a growing need to investigate the longitudinal stresses that rails are being

subjected to and to evaluate the potential requirement for rail rehabilitation. Past studies

exploring structural health monitoring (SHM) techniques for rail infrastructure have

focused on the application of discrete strain sensor technologies making it difficult to

understand the rail’s full strain profile under locomotive loading. This paper introduces a series of dynamic field tests conducted to assess the suitability of both distributed and

discrete sensors to measure longitudinal rail strain under locomotive braking. A

distributed fibre optic sensor (FOS) based on Rayleigh backscatter in addition to electrical

resistance strain gauges were used. Conclusions will be drawn as to the most applicable

rail monitoring technology and future research directions will be outlined.

1.0 Introduction

Railway bridges are being exposed to greater longitudinal forces than their original design

intended and, consequently, are becoming a growing concern as their conditions worsen

with age (1). With over 100,000 bridges, more than half predating 1920, North America’s rail network is expected to exceed its freight tonnage capacity over the next 20 years as

today’s locomotives are hauling heavier freights at higher operating speeds (2). A study

by Foutch et al. conducted to measure longitudinal forces in railway bridge decks under

the operating limits of new locomotives at the time measured forces 30 times greater than

those used to design the original structure (1). Therefore, it is imperative that condition

assessment of rail infrastructure accounts for longitudinal forces so that actions may be

taken to ensure these bridges are performing adequately under these increasing loads.

Mor

e in

fo a

bout

this

art

icle

: ht

tp://

ww

w.n

dt.n

et/?

id=

2338

3

Page 2: Longitudinal strain monitoring of rails using distributed

2

Condition assessment of rail infrastructure typically consists of periodic visual

inspections made by trained personnel walking along the railway network (3). However,

this method is only effective at identifying surface damage (3) and thus has limited value

in longitudinal force monitoring. Instead, more novel strain sensing technologies have

been utilized in recent years as methods of measuring longitudinal rail forces. Srinivas et

al. bonded electrical resistance strain gauges at discrete locations on a railway bridge and

were successful in quantifying the longitudinal force at several locations in the rail and

bridge members due to the weight of a passing locomotive (4). Wang et al. used bi-

directional fibre Bragg grating (FBG) strain sensors to accurately measure longitudinal

force at a single location on a rail (5). A limitation of these systems is that discrete strain

sensors cannot produce the full strain profile along the entire length of a rail or structural

member without using a prohibitively expensive number of sensors. This has led to the

use of distributed fibre optic sensors as an improved strain sensing technology for rail

applications. Minardo et al. measured static and dynamic strain under an in-service train

on a 60 m section of rail using a fibre optic sensor based on Brillouin optical time-domain

analysis (BOTDA) (6). This practical sensing length, coupled with the high accuracy of

the BOTDA system was still limited by its 1 m spatial resolution. This resolution may be

too large to measure significant changes in strain over short distances, which is a

possibility as wheel loads cause strain variation between ties, which typically have a

maximum spacing of 610 mm (7). Yoon et al. achieved a more practical spatial resolution

of 36 mm, in the measurement of longitudinal rail strain, using a distributed fibre-optic

sensor based on Brillouin optical correlation domain analysis (BOCDA) (8). However,

this system was not tested under field conditions with an in-service locomotive and the

sensing length was only 2.8 m. The optimal solution for longitudinal force measurement

in rail applications would be a fully distributed fibre optic strain sensor with a high spatial

resolution and practical sensing length proven under field conditions.

Distributed fibre optic sensing based on Rayleigh backscatter could offer such a solution

as this technology possesses a gauge length of 5.22 mm, sensor spacing of 2.61 mm and

a dynamic sensing range of 20 m (9). While this range limits its usefulness for large-scale

railway monitoring, it is still a practical length for condition assessment of shorter, more

critical rail sections and bridge members. Distributed sensors based on Rayleigh

backscatter have been used in the past for various structural monitoring applications.

Regier and Hoult used this fibre optic sensing system on the surface of four beams of a

reinforced concrete bridge in Madoc, Canada (10). A series of electrical resistance strain

gauges were also installed on the beams at locations directly adjacent to the fibres in order

to assess the correlation of strain data between the two technologies under a moving truck

load. Results showed good agreement between the two types of sensors proving the

usefulness of this fibre optic system in providing accurate and meaningful results in

bridge monitoring. In the context of rail applications, Wheeler et al. demonstrated the

effectiveness of this fibre optic system in measuring high resolution, dynamic rail strain

through a series of lab and field tests in Kingston, Canada (11). However, it was

concluded that vibration-induced noise in the strain data due to high locomotive speeds

limited the overall applicability of this system.

A distributed fibre optic sensing system based on Rayleigh backscatter has been used with

success in both bridge and rail monitoring. Thus, an opportunity exists to combine these

applications by assessing the effectiveness of this system in measuring longitudinal strain

in railway bridges. This information would lead to new knowledge regarding how

Page 3: Longitudinal strain monitoring of rails using distributed

3

longitudinal forces transfer through railway bridges and will give further insight into their

condition under today’s heavier train loads. The current investigation is a preliminary step

in this research aimed at conducting a series of field tests to assess the correlation of

longitudinal rail strain data between distributed and discrete sensors. The objectives are

threefold: (i) to measure discrete and distributed strains under locomotive braking, (ii)

compare discrete and distributed strain measurements, and (iii) to better understand

longitudinal force transfer in a rail. The sections that follow will provide a background

on fibre optic sensor technologies and a description of the test site, instrumentation, and

testing procedure. Results will be presented and discussed, followed by conclusions

outlining the major findings of the research.

2.0 Background

Fibre optic sensors can be classified based on the distribution of sensors along the length

of the fibre and the light scattering process that is observed in the core. Discrete, or point,

sensors have a single measurement point located at the end of the fibre. Integrated, or

long-base, sensors also have a single sensor at the end of the fibre, however, integrated

over a longer measurement base. Quasi-distributed, or multiplexed, sensors contain

multiple sensor points at regular intervals along the length of the fibre. Distributed sensors

are capable of sensing at any point along the fibre (12,13,14). For applications in the rail

industry, quasi- and fully-distributed sensors have widely been used taking advantage of

FBG techniques and Brillouin scattering.

2.1 Fibre Bragg Grating

Fibre Bragg Grating sensors are the most widely used fibre optic technique for continuous

measurement applications, as 2/3 of monitoring projects to date, using fibre optics, have

employed this quasi-distributed technology (15). Bragg gratings are density alterations in

the optical core facilitating the reflection of light and are made at regular intervals by

exposing the fiber to high-intensity ultraviolet light (16). FBG sensors can be used to

perform simultaneous measurement of temperature and strain (16) and can achieve a

spatial resolution of 2 mm (15). However, the main limitation of FBG sensors lies in their

sensing range, which is commonly limited to 100 gratings (17).

2.2 Brillouin

Brillouin-based fibre optic sensors are often used for long-distance sensing applications.

When a pulse of light is sent along an optical fibre, counter propagating “Brillouin scattering” waves, produced by stimulated acoustic vibrations, act to weaken this forward-moving pulse (18). The frequency shift between with the original pulsed light

and these Brillouin scattering waves can be measured and related to physical

perturbations affecting the fibre (19). Sensing techniques relying on this process, such as

BOTDA systems, can monitor up to 200 km (20). However, the practicality of this method

for short-range monitoring (up to 1 km (21)) is limited by the technologies’ 100 mm

spatial resolution (22).

Page 4: Longitudinal strain monitoring of rails using distributed

4

2.3 Rayleigh

Systems based on Rayleigh backscatter offer a potentially optimal solution for short-

range strain measurement applications as they possess the highest potential spatial

resolution of the distributed fibre optic sensor techniques. Rayleigh scattering is produced

by the inherent and random microscopic variations in the optical core’s refractive index

(23). Variations in the intensity of these backscattered waves is measured to detect

attenuation in the signal, which will drop due to external events acting on the fibre (24).

These systems can achieve a sensor spacing of 2.61 mm while sampling at 50 Hz, at the

expense of a limited dynamic sensing range of 20 m (9). This technique was used in

conducting the current investigation.

3.0 Experimental Procedures

A series of field tests, in which a locomotive braked over various instrumented sections

of rail, was conducted to assess the correlation between dynamic strain measured by

discrete and distributed sensing technologies. The collected data was then used to

calculate the distribution of longitudinal force in the rail in an attempt to determine the

force transfer mechanism between the axle load and the underlying rail system.

3.1 Test Site

The field tests were conducted at National Research Council Canada’s (NRC) Rail

Research Laboratory in Ottawa, Canada. A 152 m section of 100lbs RE jointed rail was

chosen for the tests, as shown in Figure 1. Each jointed rail section measured

approximately 11.8 m in length.

Figure 1. View of the 100lbs RE rail used at the test site.

Page 5: Longitudinal strain monitoring of rails using distributed

5

3.2 Instrumentation

The outer side of two adjacent sections of rail was instrumented for these tests. Optical

fibre, with an 8.2 µm diameter core and nylon coating, was used in conjunction with a

LUNA Innovations ODiSI-B dynamic analyzer which possesses a maximum dynamic

sensing range of 20 m, gauge length of 5.22 mm, sensor spacing of 2.61 mm and a strain

accuracy of +/- 10 µε (9). The instrumented surface of the rail was cleaned using water

and a degreasing agent prior to bonding the fibres using a cyanoacrylate adhesive (Loctite

4861). The complete instrumentation plan is illustrated in Figure 2.

Figure 2. Instrumentation plan. Black lines – fibre optic cable, blue and red boxes – strain gauges.

Two adjacent segments of the same rail were instrumented. Rail 1 consisted of a 3.0 m

long section of fibre running along the rail’s flange and head at a height of 18 mm and

135 mm, respectively, above the bottom of the rail. Looping the fibre in this orientation

enables the measurement of strain at two heights at every point in the rail, allowing a

complete strain profile to be derived at each sensing point. Rail 2 was instrumented in a

similar orientation, however, over a longer length of 7.5 m. Rail 2 was also instrumented

with a pair of electrical resistance strain gauges bonded at elevations of 50 mm and 90

mm in the same longitudinal location. The gauges were placed equidistance between two

adjacent ties situated within the length of the rail containing fibres, as shown in Figure 3.

Uniaxial strain gauges, from Tokyo Sokki Kenkyujo Co., Ltd., with a 5 mm gauge length

and 350 Ω impedance were used (25).

Page 6: Longitudinal strain monitoring of rails using distributed

6

Figure 3. View of rail 2 with strain gauges and fibre optic sensors attached.

3.3 Testing Procedure

The braking tests were conducted using the CSTX 1003 locomotive shown in Figure 4.

Figure 4. CSTX 1003 locomotive used for the field tests.

For each test, the locomotive started from rest away from the instrumented section and

accelerated so that its speed approaching the section would be less than 16 km/hour to

limit noise in the fibre data. The locomotive then applied its brakes just before its front

wheel axle reached the instrumented section and so that it would come to a complete stop

with the front wheel axle directly over the fibres. Sensor data was recorded once the

locomotive was within 3 m of the instrumented section.

Page 7: Longitudinal strain monitoring of rails using distributed

7

4.0 Results and Discussion

4.1 Strain Gauge Data

Figure 5 shows the strain measured by the two electrical resistance gauges during a

braking test in which only the locomotive’s front bogie passed over the gauged section of

rail before coming to a complete stop. The red and blue data curves represent the strain

measured by the gauges bonded at a height of 50 mm and 90 mm, respectively, above the

bottom of the rail.

Figure 5. Discrete strain gauge data from a locomotive braking test.

The sharp spikes in the strain measurements (circled in Figure 5) correspond to points

during the test in which one of the locomotive’s wheels passed directly over the vertical

pair of strain gauges. The equal and opposite nature of the data indicates that the gauges

were bonded on either side of the rail’s neutral axis. It should also be noted that the blue

curve shows an abrupt positive peak in strain, indicated on Figure 5, when the

locomotive’s wheel is directly over top of the gauges suggesting the occurrence of

localized stress concentrations.

4.2 Distributed FOS Data

Figure 6 shows the strain measured along the 3 metre length of fibre bonded to Rail 1 and

at the point in the test when the locomotive had come to a complete stop. The red and

blue curves correspond to the fibre bonded to the rail at heights of 18 mm and 135 mm,

respectively, above the bottom of the rail. It should be mentioned that when looking at

Figure 6, the locomotive had been travelling from the right side to the left side of the

figure prior to the readings being taken.

Page 8: Longitudinal strain monitoring of rails using distributed

8

Figure 6. Distributed strain data measured by the FOS from Rail 1 during a locomotive braking

test.

As seen on Figure 6 and suggested by the spikes in the strain curves at 2.5 m, the

locomotive came to a complete stop with only its front wheel reaching the rail segment

instrumented with the fibre. The data presented in Figure 6 illustrates the important

advantage that a distributed FOS based on Rayleigh backscatter has over conventional

strain gauges: that the high spatial resolution of the sensor allows it to capture the

complete strain response of the rail due to locomotive loading.

4.3 Comparison between Strain Gauge and FOS Data

A comparison between the strain measured by the distributed and discrete sensors is

shown in Figure 7. It should be noted that the strain gauge and FOS data was collected

from separately conducted tests. The solid red curve displays a strain spike measured by

the electrical resistance gauge bonded to Rail 2 at a height of 50 mm above the bottom of

the rail. The solid blue curve displays a similar spike measured by the fibre optic sensor

at the same discrete location as the electrical resistance gauge on Rail 2, but at a height

of 18 mm above the bottom of the rail. The red-dashed curve is the strain calculated by

extrapolating the total strain profile formed by the two electrical resistance gauges to the

elevation of the fibre on the rail.

Page 9: Longitudinal strain monitoring of rails using distributed

9

Figure 7. Comparison between the FOS, measured strain gauge and adjusted strain gauge data.

The results displayed in Figure 7 indicate that the FOS experiences more noise than the

electrical resistance gauge. Additionally, the maximum fibre optic strain is lower than the

maximum adjusted strain as this data was collected from separately conducted tests.

These results also indicate that the FOS is less effective than the strain gauges at capturing

strain peaks, which may be resolved in future tests by using a higher sampling rate with

the FOS.

4.4 Understanding Rail Behaviour

Knowing the strain at two elevations on the same section of rail permits the calculation

of curvature, which can be used to calculate axial force at this location if the geometric

centroid of the rail is assumed (11). Figure 8 shows the axial force calculated from the

strain data in Figure 5.

Figure 8. Axial force with time measured by the strain gauges under locomotive braking.

Page 10: Longitudinal strain monitoring of rails using distributed

10

As indicated on Figure 8, the rail experiences tension immediately before the

locomotive’s wheel passes the gauges and compression immediately after. Figure 8 also

shows that the rail experiences tension when it is between adjacent wheel sets of the same

bogie but is in compression when between adjacent bogies. It should be noted that the

effects of localized stress concentrations on the peaks of the measured strain gauge data,

as seen in Figure 5, were replaced by linearly interpolating between the points of strain

immediately before and after the positive strain spikes to permit the calculation of axial

force at these critical points in the tests.

This same concept was applied to the FOS data. Figure 9 displays the results of

calculating the axial force along the entire length of fibre using the distributed strain data

shown in Figure 6. A side view of the instrumented rail is included in Figure 9 to illustrate

the orientation of the fibres. As seen on Figure 9, the rail experiences a maximum axial

compression at the location of the locomotive’s wheel. Additionally, Figure 9 shows that

points of strain inflection, labelled IP on the strain curve, correspond to sudden transitions

in the sign of the axial force at that location on the rail. While Figure 8 presents interesting

information regarding the axial force in the rail at a single location, the results from Figure

9 demonstrate the advantage that the distributed FOS has over discrete sensor

technologies in that the axial force distribution can be obtained with time.

Figure 9. Distributed axial force calculated along the length of the rail.

Page 11: Longitudinal strain monitoring of rails using distributed

11

5. Conclusions

A series of field tests was conducted in which a locomotive braked to a complete stop

over various segments of rail instrumented with electrical resistance strain gauges and

fibre optic strain sensors. The objectives of this research were to investigate the suitability

of discrete and distributed sensors to measure dynamic rail strain and to assess their

correlation. The collected data was also used to determine the distribution of axial force

in the rail under locomotive braking to better understand axial force transfer between the

wheels and the underlying rail system. The results of these tests led to the following

conclusions:

Electrical resistance strain gauges experience less noise than the FOS and are

more effective at measuring strain peaks.

The distributed nature of the FOS provides a more complete understanding of the

response of the rail under locomotive loading, as compared to the strain gauges.

The rail experiences a maximum axial compression at the wheel location and axial

tension between adjacent bogie wheels.

The insight gained from these tests will aid in future research which should include full-

scale longitudinal strain monitoring of an in-service railway bridge.

Acknowledgements

The authors of this paper are grateful to National Research Council Canada for making

this research possible and to Eric Pannese and Alireza Roghani for providing assistance

with the field testing.

References

1. DA Foutch, TW Kim, DE Otter and BE Doe, “Investigation of Longitudinal Forces

in a Concrete Railroad Trestle”, J. Bridge Eng. 11(5), pp 618-625, 2006.

2. F Moreu, RE Kim and BF Spencer, “Railroad bridge monitoring using wireless

smart sensors”, Struct. Control and Health Monit. 24(2), pp 1-17, 2016.

3. P De Ruvo, G De Ruvo, A Distante, M Nitti, E Stella and F Marino, “A Visual Inspection System for Rail Detection & Tracking in Real Time Railway

Maintenance”, The Open Cybernetics and Systemics Journal 208(57), pp 57-67,

2008.

4. V Srinivas, K Ramanjaneyulu, KS Kumar, S Parivallal, K Kesavan, K Ravisankar,

N Lakshmanan and NR Iyer, “Evaluation of Longitudinal Force on a Railway Bridge Based on Strain Measurements”, Experimental Techniques 37(1), pp 55-67,

2011.

5. P Wang, K Xie, L Shao, L Yan, J Xu and R Chen, “Longitudinal force measurement in continuous welded rail with bi directional FBG strain sensors”, Smart Mater. Struct. 25(1), 2016.

Page 12: Longitudinal strain monitoring of rails using distributed

12

6. A Minardo, A Coscetta, G Porcaro, D Giannetta, R Bernini and L Zeni, “Distributed optical fiber sensors for integrated monitoring of railway infrastructures”, Structural Monitoring and Maintenance 1(2), pp 173-182, 2014.

7. Canadian National (CN), “Engineering specifications for industrial tracks”. Web. 2015. Retrieved from https://www.cn.ca/-/.../Engineering-Specifications-for-

Industrial-Tracks-en.pdf?la=en

8. HJ Yoon, KY Song, JS Kim and DS Kim, “Longitudinal strain monitoring of rail using a distributed fiber sensor based on Brillouin optical correlation domain

analysis”, NDT&E International 44(7), pp 637-644, 2011.

9. Luna Innovations, “ODiSI-B Users Guide”. Web. 2017. Retrieved from

https://lunainc.com/wp-content/uploads/2014/05/ODiSI-B-Users-Guide.pdf

10. R Regier and NA Hoult, “Distributed Strain Behaviour of a Reinforced Concrete

Bridge: Case Study”, J. Bridge Eng. 19(12), pp 1-8, 2014.

11. LN Wheeler, E Pannese, NA Hoult, AW Take and L Hoat, “Measurement of distributed dynamic rail strains using a Rayleigh backscatter based fiber optic

sensor: Lab and field evaluation”, Transportation Geotechnics 14, pp. 70-80, 2018.

12. E Udd, “Fiber Optic Sensors”, Wiley. 1991. 13. E Udd, “Fiber optic smart structures”, Wiley, New York. 1995. 14. D Inaudi, “Fiber optic smart sensing”, Optical Measurement techniques and

applications, P.K. Rastogi editor, Artech House, pp 255-275, 1997.

15. P Ferdinand, “The evolution of optical fiber sensors technologies during the 35 last years and their applications in structural health monitoring”, EWSHM Conf. Prof., pp 914-929, 2014.

16. D Inaudi and A del Grosso, “Fiber optic sensors for structural control”, 14th WCEE

Conf. Proc., 2008.

17. A Barrias, JR Cases and S Villabla, “A Review of Distributed Optical Fiber Sensors for Civil Engineering Applications”, Sensors 16(748), pp 1-35, 2016.

18. N Shibata, RG Waarts and RP Braun, “Brillouin-gain spectra for single-mode fibers

having pure-silica, GeO2-doped, and P2O5-doped cores”, Opt. Lett. 12(4), pp 269-

271, 1987.

19. M Tateda, T Horiguchi, T Kurashima and K Ishihara, “First measurement of strain along field-installed optical fibers using Brillouin spectroscopy”, Journal of Lightwave Technology 8(9), pp 1269-1272, 1990.

20. X Bao and L Chen, “Recent progress in distributed fiber optic sensors”, Sensors 12(7), pp 8601-8639, 2012.

21. AS George, “Distributed Fibre Optic Sensors – Brillouin Optical Time Domain

Analysis (BOTDA) Sensor in Simple Language”, International Journal of

Engineering Research 5(2), pp 131-136, 2016.

22. I. Sovran, A. Motil, and M. Tur, “Frequency-scanning BOTDA with ultimately fast

acquisition speed”, IEEE Photonics Technology Letters 27(13), 1426–1429, 2015.

23. M Froggatt and J Moore, “High-spatial-resolution distributed strain measurement in

optical fiber with Rayleigh scatter”, Applied Optics 37(10), pp 1735-1740. 1998.

24. TS Francis and S Yin, “Fibre Optic Sensors”, Marcel Dekker Inc., New York, 2002.

25. Tokyo Sokki Kenkyojo, “F series Foil strain gauge”. Web. (n.d.). Retrieved from http://www.tml.jp/e/product/strain_gauge/catalog_pdf/Fseries.pdf