RADIOGRAPHIC TESTING WITH LO-RAD EQUIPMENT
Lo-Rad is a flexible system which fits any shape and size of steel or pipe work.Lo-Rad operates efficiently under varying temperature conditions -50 to 120 Degrees CelsiusLo-Rad system is easily attached to any specimen due to the patented self adhesive envelopesLo-Rad system allows you to use your existing and standard radiographic equipment, Techops 660, 880 Gammamat TI, TIF etc
Lo-Rad Features
Complete System
The case will hold the following
Mazel mats with envelopesPrimary beam Mazel mats & envelopeMazel Outer and standard inner guide tubeCollimatorEllipse standFlash boxThe system is easily transported on site. The unit is waterproof and has castor wheels for maneuverability and storing.
Lo-Rad Mazel Mats
915 x 305 x 9.5mm11.3kgLead equivalent of 3.3mmSpecificationsFlexible!!!
Self Adhesive Mats & Ellipse Stand For work on 2 Inch pipe work - DWDIAllows for required SFD
Mazel Guide Tube & Collimator
39mm od 19 mm id 8 kgMax Temp 120 DegLength 1.5mSpecificationsTungsten CollimatorStandard Guide TubeMazel Guide Tube ShieldFlexible!
Mazel Flash Box
Flash Box weight 11KgSpecifications
The Mazel Flash Box is designed to reduce any flash radiation which might be emitted when the source is wound out
Step by StepStep 1Attach Guide Tube to Isotope/ContainerStep 2Insert Isotope/Container into Flash BoxStep 3Attach collimator to weld or specimenStep 4Enclose collimator and weld with Mazel MatsStep 5Expose Weld
CONTACTThank you for your time