LM-79 Distribution Test Report (Luminaire) Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire Report No.: PHM-RPT-171026-D05 Date: October 26, 2017 Page 1 of 9 LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution, Electrical Characteristics and Efficacy. Report Prepared for: Vantage Lighting 181 Narragansett Park Drive East Providence, RI 02916 USA Telephone: (860) 564-4512 Description : 3” Recessed Downlight Model Tested: V3CRRU-1335K-N WO/CS#: R3243 Report Issue Date: October 26, 2017 Date of Test(s): October 24-26, 2017 Total Number of Pages : 9 (including this page) Report Reviewed by: Mark Razvi Photometric Lab Supervisor Curtis-Straus

LM-79 Distribution Testing: Total Luminous Flux, ... 3026 3001 3009 3021 2.5 3017 3014 3034 3039 3024 3008 2998 3024 ... 2992 3000 2994 2980 2984 2988 3001 3007 3026 ... 2993 3017

Embed Size (px)

Citation preview

Page 1: LM-79 Distribution Testing: Total Luminous Flux, ... 3026 3001 3009 3021 2.5 3017 3014 3034 3039 3024 3008 2998 3024 ... 2992 3000 2994 2980 2984 2988 3001 3007 3026 ... 2993 3017

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D05 Date: October 26, 2017

Page 1 of 9

LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution, Electrical

Characteristics and Efficacy.

Report Prepared for:

Vantage Lighting 181 Narragansett Park Drive East Providence, RI 02916

USA Telephone: (860) 564-4512

Description : 3” Recessed Downlight

Model Tested: V3CRRU-1335K-N WO/CS#: R3243

Report Issue Date: October 26, 2017 Date of Test(s): October 24-26, 2017 Total Number of Pages : 9 (including this page)

Report Reviewed by:

Mark Razvi

Photometric Lab Supervisor Curtis-Straus

Page 2: LM-79 Distribution Testing: Total Luminous Flux, ... 3026 3001 3009 3021 2.5 3017 3014 3034 3039 3024 3008 2998 3024 ... 2992 3000 2994 2980 2984 2988 3001 3007 3026 ... 2993 3017

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D05 Date: October 26, 2017

Page 2 of 9

DETAILED PRODUCT DESCRIPTION Model # V3CRRU-1335K-N CS/WO# R3243 Description 3” Recessed Downlight Supply Voltage 120VAC Pictures:

Page 3: LM-79 Distribution Testing: Total Luminous Flux, ... 3026 3001 3009 3021 2.5 3017 3014 3034 3039 3024 3008 2998 3024 ... 2992 3000 2994 2980 2984 2988 3001 3007 3026 ... 2993 3017

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D05 Date: October 26, 2017

Page 3 of 9

Curtis-Straus Photometric Testing Information

Photometric Testing is performed in accordance with the procedures outlined in LM-79-2008 . The test sample is evaluated for photometric and electrical characteristics using the equipment listed below.

Curtis-Straus Environmental Testing Info Curtis-Straus testing laboratory temperature during testing: 25.2 °C .

LIST OF EQUIPMENT USED: Description Model

No. Serial No. Asset

No Cal. Date

Cal. Due

Yokogawa Power Meter

WT-310E C2SK21021V

2356 12-19-16` 12-19-17

Chroma AC Power Supply

61603 616030001283 2355 04-21-17 04-21-18

LabSphere Type-C GoniometerSystem

PM-150-140 022172153 AA-30058-195

10-17-17 11-17-17

Digital Thermometer

4627 160739886 2392 09-07-16 09-07-18

This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production.

Page 4: LM-79 Distribution Testing: Total Luminous Flux, ... 3026 3001 3009 3021 2.5 3017 3014 3034 3039 3024 3008 2998 3024 ... 2992 3000 2994 2980 2984 2988 3001 3007 3026 ... 2993 3017

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D05 Date: October 26, 2017

Page 4 of 9

LM-79-2008 Distribution Test Data

Model # V3CRRU-1335K-N CS/WO# R3243 Description 3” Recessed Downlight Supply Voltage 120VAC

Result of Tests

Photometric and Electrical Test Data

Input Voltage: 120 VAC

Base Orientation: Base Up

Lumens (lm) Watts (W) Volts (VAC) Amps (A) Efficacy PF Ithd (%)

1350.11 14.47 120.21 0.12 93.30 0.9892 0.15

Luminous Intensity Summary: Cd Illumination Cone of Light Mounting Ht: 10 ft.

Page 5: LM-79 Distribution Testing: Total Luminous Flux, ... 3026 3001 3009 3021 2.5 3017 3014 3034 3039 3024 3008 2998 3024 ... 2992 3000 2994 2980 2984 2988 3001 3007 3026 ... 2993 3017

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D05 Date: October 26, 2017

Page 5 of 9

IsoCandela Plot

Zonal Lumens Summary Lumens per Zone

Page 6: LM-79 Distribution Testing: Total Luminous Flux, ... 3026 3001 3009 3021 2.5 3017 3014 3034 3039 3024 3008 2998 3024 ... 2992 3000 2994 2980 2984 2988 3001 3007 3026 ... 2993 3017

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D05 Date: October 26, 2017

Page 6 of 9

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 3066 3066 3066 3066 3066 3066 3066 3066 3066 3066 3066 3066 3066 3066 3066 3066 3066

0.1 3050 3050 3077 3094 3079 3090 3077 3092 3086 3080 3075 3074 3061 3042 3017 3021 3043

0.2 3048 3055 3081 3096 3083 3082 3070 3087 3090 3083 3071 3068 3057 3037 3014 3028 3047

0.3 3046 3060 3083 3098 3087 3075 3064 3081 3093 3085 3072 3061 3052 3032 3017 3035 3051

0.4 3040 3062 3085 3094 3088 3069 3062 3075 3092 3087 3073 3063 3049 3032 3020 3034 3048

0.5 3034 3063 3086 3088 3088 3065 3065 3069 3091 3088 3076 3065 3046 3035 3024 3032 3042

0.6 3029 3064 3080 3081 3088 3061 3067 3066 3088 3089 3081 3068 3046 3038 3030 3030 3036

0.7 3029 3058 3073 3075 3080 3063 3070 3069 3081 3091 3085 3074 3051 3044 3035 3023 3032

0.8 3028 3051 3067 3069 3072 3066 3072 3071 3074 3092 3085 3081 3057 3050 3035 3017 3028

0.9 3031 3043 3061 3064 3065 3070 3074 3074 3070 3093 3085 3084 3061 3055 3033 3014 3024

1 3037 3039 3054 3068 3061 3070 3067 3077 3067 3093 3083 3081 3064 3052 3031 3016 3028

1.1 3043 3034 3054 3072 3057 3070 3060 3080 3065 3094 3076 3078 3067 3049 3026 3019 3033

1.2 3044 3032 3057 3074 3057 3069 3053 3074 3069 3094 3068 3073 3064 3045 3020 3022 3036

1.3 3041 3034 3060 3074 3061 3060 3046 3067 3073 3093 3063 3066 3059 3039 3015 3026 3038

1.4 3038 3037 3061 3075 3065 3052 3039 3061 3077 3092 3063 3060 3054 3033 3018 3030 3040

1.5 3032 3040 3061 3070 3064 3044 3035 3053 3075 3089 3062 3059 3050 3032 3021 3028 3038

1.6 3024 3042 3061 3062 3062 3038 3036 3045 3072 3084 3064 3060 3046 3035 3024 3025 3030

1.7 3017 3044 3055 3053 3059 3032 3038 3041 3068 3079 3068 3060 3044 3037 3028 3022 3023

1.8 3016 3040 3048 3047 3050 3030 3039 3043 3060 3071 3073 3065 3048 3041 3032 3015 3018

1.9 3016 3033 3042 3041 3041 3032 3040 3046 3051 3063 3071 3071 3053 3044 3030 3008 3014

2 3016 3026 3035 3035 3033 3034 3040 3047 3045 3057 3067 3072 3056 3047 3025 3003 3010

2.1 3020 3020 3028 3038 3028 3033 3033 3047 3041 3056 3063 3068 3059 3042 3020 3003 3013

2.2 3023 3015 3027 3041 3023 3031 3024 3047 3038 3055 3055 3063 3061 3038 3014 3004 3017

2.3 3023 3010 3030 3043 3021 3029 3016 3041 3039 3056 3047 3057 3059 3032 3007 3005 3021

2.4 3020 3012 3033 3041 3022 3018 3007 3033 3043 3060 3040 3050 3054 3026 3001 3009 3021

2.5 3017 3014 3034 3039 3024 3008 2998 3024 3046 3064 3041 3043 3049 3019 3004 3013 3020

2.6 3010 3015 3034 3034 3022 2998 2991 3016 3043 3062 3042 3041 3042 3015 3007 3012 3017

2.7 3001 3015 3034 3024 3017 2992 2991 3007 3040 3058 3043 3042 3035 3017 3009 3008 3008

2.8 2992 3016 3025 3013 3013 2986 2990 3000 3036 3054 3046 3044 3029 3018 3011 3004 2999

2.9 2991 3011 3015 3006 3002 2982 2990 3000 3026 3045 3049 3046 3029 3020 3012 2997 2993

3 2992 3002 3006 3000 2991 2983 2989 3001 3016 3035 3046 3049 3030 3023 3010 2988 2988

3.1 2992 2992 3000 2994 2980 2984 2988 3001 3007 3026 3037 3051 3031 3026 3003 2980 2984

3.2 2994 2986 2994 2994 2976 2981 2982 3000 3003 3024 3029 3044 3034 3022 2995 2978 2984

3.3 2997 2981 2991 2996 2971 2978 2973 2999 2999 3023 3022 3036 3037 3017 2988 2976 2986

3.4 2996 2975 2992 2997 2968 2974 2965 2993 2998 3023 3014 3029 3035 3012 2981 2976 2988

3.5 2989 2977 2994 2992 2968 2963 2955 2983 2999 3024 3007 3021 3031 3004 2974 2979 2988

Page 7: LM-79 Distribution Testing: Total Luminous Flux, ... 3026 3001 3009 3021 2.5 3017 3014 3034 3039 3024 3008 2998 3024 ... 2992 3000 2994 2980 2984 2988 3001 3007 3026 ... 2993 3017

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D05 Date: October 26, 2017

Page 7 of 9

3.6 2982 2979 2992 2988 2968 2952 2944 2973 3001 3026 3010 3014 3027 2997 2974 2982 2988

3.7 2974 2979 2988 2981 2966 2941 2935 2964 2997 3024 3013 3011 3018 2991 2975 2981 2986

3.8 2965 2976 2983 2969 2960 2933 2933 2954 2993 3017 3015 3012 3009 2990 2976 2976 2977

3.9 2956 2973 2973 2957 2954 2925 2931 2946 2988 3011 3012 3013 3000 2989 2978 2972 2967

4 2954 2967 2962 2948 2944 2919 2929 2945 2978 3000 3009 3013 2998 2989 2979 2964 2958

4.1 2955 2957 2951 2941 2932 2917 2927 2944 2968 2989 3003 3014 2996 2992 2978 2955 2951

4.2 2955 2947 2946 2935 2920 2916 2925 2942 2958 2977 2992 3014 2994 2994 2971 2946 2943

4.3 2956 2938 2942 2933 2912 2913 2918 2940 2952 2974 2981 3004 2996 2991 2964 2943 2942

4.4 2956 2931 2938 2934 2904 2909 2907 2938 2945 2970 2973 2995 2998 2985 2956 2940 2943

4.5 2956 2924 2938 2934 2898 2904 2895 2932 2941 2968 2967 2985 2997 2979 2949 2938 2944

4.6 2948 2923 2939 2927 2897 2894 2884 2921 2940 2969 2962 2977 2992 2970 2941 2939 2943

4.7 2940 2924 2936 2920 2896 2881 2873 2911 2939 2970 2962 2968 2987 2960 2938 2940 2941

4.8 2931 2924 2928 2912 2893 2869 2862 2899 2935 2966 2962 2964 2979 2951 2938 2940 2939

4.9 2921 2920 2921 2899 2887 2859 2860 2887 2930 2960 2963 2965 2969 2949 2938 2934 2930

5 2910 2917 2911 2886 2881 2849 2857 2875 2925 2953 2957 2966 2959 2946 2938 2928 2920

5.1 2905 2911 2899 2876 2871 2841 2855 2872 2915 2942 2950 2964 2955 2944 2938 2922 2911

5.2 2903 2900 2887 2873 2858 2838 2850 2869 2904 2930 2943 2961 2951 2944 2937 2912 2901

5.3 2900 2888 2881 2871 2845 2836 2846 2865 2893 2917 2931 2959 2948 2945 2929 2901 2892

5.4 2899 2878 2876 2863 2835 2832 2838 2862 2885 2911 2919 2948 2950 2941 2921 2894 2887

5.5 2898 2871 2871 2851 2825 2826 2825 2858 2876 2906 2909 2937 2951 2936 2913 2889 2885

5.6 2896 2863 2870 2839 2816 2820 2812 2852 2867 2901 2902 2925 2950 2930 2904 2885 2882

5.7 2887 2859 2868 2831 2813 2809 2800 2841 2865 2899 2896 2918 2942 2920 2894 2884 2881

5.8 2878 2857 2864 2825 2810 2796 2788 2831 2863 2897 2893 2910 2934 2909 2889 2885 2879

5.9 2869 2855 2853 2819 2807 2783 2776 2818 2860 2894 2892 2904 2924 2898 2888 2885 2878

6 2857 2851 2842 2815 2801 2772 2771 2805 2854 2886 2890 2904 2912 2894 2887 2880 2868

6.1 2845 2846 2830 2812 2796 2761 2768 2792 2848 2878 2883 2904 2901 2890 2886 2874 2859

6.2 2838 2841 2817 2809 2787 2752 2765 2785 2839 2868 2874 2900 2894 2887 2884 2868 2849

6.3 2835 2828 2804 2799 2774 2749 2759 2779 2826 2854 2865 2893 2890 2887 2883 2856 2837

6.4 2832 2815 2796 2790 2761 2746 2753 2773 2814 2840 2852 2886 2885 2887 2873 2844 2826

6.5 2829 2802 2790 2779 2751 2742 2745 2769 2802 2830 2838 2875 2883 2883 2862 2833 2817

6.6 2827 2793 2784 2766 2741 2735 2731 2765 2790 2822 2826 2862 2881 2876 2852 2826 2812

6.7 2824 2783 2781 2753 2732 2728 2716 2759 2779 2814 2821 2849 2878 2868 2840 2819 2808

6.8 2813 2778 2777 2743 2728 2717 2704 2747 2773 2812 2815 2841 2872 2858 2829 2814 2804

6.9 2802 2775 2772 2738 2724 2703 2693 2735 2768 2809 2811 2834 2865 2845 2822 2812 2801

7 2790 2772 2760 2733 2720 2689 2683 2722 2763 2805 2808 2828 2856 2833 2818 2811 2799

7.1 2777 2765 2749 2728 2711 2676 2676 2709 2757 2797 2806 2826 2843 2826 2815 2805 2790

7.2 2764 2757 2736 2724 2702 2665 2672 2695 2752 2789 2796 2823 2830 2818 2811 2799 2779

7.3 2755 2748 2723 2719 2691 2653 2668 2685 2745 2778 2785 2819 2819 2812 2807 2792 2768

7.4 2752 2733 2710 2707 2675 2647 2660 2677 2729 2763 2774 2808 2811 2810 2803 2779 2755

7.5 2748 2718 2701 2694 2659 2641 2650 2669 2714 2748 2761 2798 2802 2808 2793 2765 2741

Page 8: LM-79 Distribution Testing: Total Luminous Flux, ... 3026 3001 3009 3021 2.5 3017 3014 3034 3039 3024 3008 2998 3024 ... 2992 3000 2994 2980 2984 2988 3001 3007 3026 ... 2993 3017

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D05 Date: October 26, 2017

Page 8 of 9

7.6 2744 2704 2696 2680 2646 2636 2641 2665 2701 2737 2747 2786 2799 2804 2782 2752 2729

7.7 2740 2694 2691 2665 2635 2628 2625 2660 2689 2727 2735 2772 2797 2795 2771 2742 2722

7.8 2736 2685 2685 2651 2625 2621 2609 2655 2677 2718 2727 2757 2794 2787 2758 2732 2715

7.9 2724 2678 2680 2638 2619 2610 2594 2644 2671 2713 2719 2748 2787 2775 2745 2725 2710

8 2710 2675 2673 2632 2614 2595 2584 2634 2666 2709 2712 2741 2779 2761 2735 2722 2707

8.1 2696 2672 2660 2626 2609 2579 2574 2621 2661 2704 2707 2734 2770 2746 2729 2718 2703

8.2 2683 2665 2647 2619 2598 2565 2566 2604 2655 2695 2702 2728 2756 2736 2723 2712 2694

8.3 2670 2654 2633 2610 2586 2551 2560 2588 2648 2685 2692 2723 2742 2726 2718 2704 2682

8.4 2659 2644 2620 2601 2573 2538 2555 2576 2640 2673 2678 2716 2730 2717 2713 2695 2670

8.5 2653 2629 2606 2587 2557 2530 2545 2566 2626 2658 2664 2703 2719 2712 2708 2682 2656

8.6 2647 2614 2596 2571 2540 2523 2533 2556 2612 2643 2649 2690 2708 2707 2698 2668 2641

8.7 2641 2600 2590 2555 2526 2516 2522 2550 2598 2629 2634 2675 2701 2702 2686 2654 2627

8.8 2634 2590 2584 2543 2516 2508 2506 2544 2582 2618 2618 2660 2696 2693 2674 2642 2619

8.9 2627 2581 2577 2533 2505 2500 2489 2537 2567 2606 2610 2644 2691 2685 2659 2631 2610

9 2615 2572 2569 2522 2497 2490 2474 2526 2556 2597 2602 2633 2681 2673 2644 2622 2603

9.1 2600 2566 2561 2515 2490 2474 2464 2514 2547 2591 2594 2626 2671 2658 2630 2616 2597

9.2 2585 2559 2546 2509 2484 2458 2453 2501 2538 2584 2586 2618 2659 2643 2621 2611 2591

9.3 2571 2550 2531 2500 2472 2443 2444 2485 2531 2574 2577 2611 2642 2630 2613 2603 2582

9.4 2558 2538 2516 2487 2461 2430 2437 2468 2524 2563 2566 2603 2626 2617 2605 2594 2570

9.5 2545 2525 2501 2475 2449 2417 2431 2455 2517 2551 2551 2596 2610 2605 2599 2585 2558

9.6 2539 2511 2487 2461 2432 2406 2421 2443 2501 2533 2536 2580 2596 2598 2592 2571 2543

9.7 2532 2495 2475 2445 2415 2396 2409 2432 2485 2515 2520 2564 2582 2590 2581 2555 2526

9.8 2525 2479 2467 2430 2399 2387 2398 2424 2469 2499 2504 2547 2572 2583 2568 2539 2510

9.9 2516 2468 2459 2417 2388 2378 2382 2417 2453 2486 2487 2530 2564 2574 2555 2526 2499

10 2506 2459 2450 2407 2377 2370 2366 2410 2438 2473 2478 2513 2556 2565 2539 2513 2489

15 1862 1840 1840 1814 1812 1816 1814 1814 1822 1832 1834 1852 1855 1856 1875 1869 1851

20 1331 1347 1352 1346 1354 1356 1352 1355 1350 1337 1330 1318 1312 1293 1303 1325 1334

25 832 861 885 898 922 914 904 914 896 856 837 837 830 811 796 804 829

30 416 426 439 454 481 475 468 474 462 430 418 423 420 418 407 401 414

35 122 123 127 126 128 126 124 127 126 123 121 120 125 129 126 122 121

40 49 49 50 50 50 49 48 49 50 49 48 50 51 51 50 49 49

45 27 26 26 26 26 26 26 26 27 27 26 27 27 28 27 27 27

50 17 16 16 16 16 16 16 16 17 17 16 17 17 18 18 18 17

55 11 11 10 10 10 10 10 11 11 11 11 11 12 12 11 11 11

60 8 7 7 7 7 7 8 7 7 7 7 8 8 8 8 8 8

65 6 6 6 6 6 6 7 7 6 6 6 6 6 6 6 6 6

70 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

75 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

80 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

85 5 5 5 5 5 5 5 5 5 5 6 6 6 6 6 5 5

Page 9: LM-79 Distribution Testing: Total Luminous Flux, ... 3026 3001 3009 3021 2.5 3017 3014 3034 3039 3024 3008 2998 3024 ... 2992 3000 2994 2980 2984 2988 3001 3007 3026 ... 2993 3017

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D05 Date: October 26, 2017

Page 9 of 9

90 4 3 3 3 4 3 3 4 4 4 3 3 4 4 3 4 4

95 3 3 3 4 3 3 4 4 3 3 3 3 3 3 4 3 3

100 3 4 3 4 4 4 3 4 4 4 4 3 3 4 3 3 3

105 4 3 4 4 4 4 4 3 4 3 4 3 3 3 3 3 4

110 4 3 3 4 3 4 4 4 4 3 3 4 4 3 4 3 3

115 3 3 3 4 4 4 4 4 3 4 3 3 3 3 3 3 3

120 4 3 3 3 3 3 3 4 4 3 4 4 3 4 3 4 3

125 4 4 4 4 4 3 4 3 3 4 3 3 4 3 4 3 3

130 4 3 4 4 4 4 3 4 4 4 4 4 3 3 4 3 4

135 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

140 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

145 4 5 5 5 5 5 5 5 5 4 4 5 5 5 4 5 5

150 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

155 5 5 5 6 6 6 5 5 5 5 5 5 5 5 5 5 5

160 6 6 6 6 6 6 6 6 6 6 6 6 6 5 6 6 6

165 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

170 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

175 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

180 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6