Standarts Rated Voltage Rated Current Rated Power Rated Frequency Phase Impedance Tolerance of Inductance Thermal Strength Linearity Protection Class İnsulation Class Impregnation Cooling Ambient Temperature Humidity Altitude Design Winding Terminals TECHNICAL DATA : TS EN61558-2-20, TS EN60076-6 : CE Conformity : 230V...400V...600V...1000V : 4A.................................3000A : 0,37kW.....................1600kW : 50Hz : 1 - 3 : 4% or demanded : ±5% : 1,15In continuous : 1,4In above : IP00 : F Class 1550C : H Class Varnish Vacuum Impregnation : Natural : 400C : 95% : 1000m : 3 phase, Iron Cored, with air gap : Copper, Aluminium : Terminal blocks, Cable lugs or Copper bars Line-load reactors help to keep your equipment to run longer by absorbing many of the disturbances, especially the spikes coming from the electrical system, which otherwise damage or shut down your inverters, variable speed controllers, or other sensitive equip- ments. They are the modern technological solution to the problems of the inverter and drive applications. They are very effective at reducing harmonic distor- tion produced by inverters and drives. • Decrease the ratio of dv/dt • Decrease peak voltage • Increase the efficiency of the motor • Decrease the noise of the motor • Decrease over heating of the motor • Lengthens the isolation life of the motor • Decrease the harmonic distortion • Absorb the surges and the spikes • Decrease voltage peaks • Improve the true power factor • Lengthens the operating life of the inverters THE BENEFITS OF LINE REACTORS THE BENEFITS OF LOAD REACTORS LINE - LOAD REACTORS

LINE - LOAD REACTORS...LINE REACTORS DATA SHEET 400V, 3 PHASE, 4% IMPEDANCE 230V, 1PHASE, 4% IMPEDANCE GKRTN3704 GKRTN5504 GKRTN7504 GKRT1N104 GKRT1N504 GKRT204 GKRT304 GKRT404 GKRT504

  • Upload
    others

  • View
    23

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LINE - LOAD REACTORS...LINE REACTORS DATA SHEET 400V, 3 PHASE, 4% IMPEDANCE 230V, 1PHASE, 4% IMPEDANCE GKRTN3704 GKRTN5504 GKRTN7504 GKRT1N104 GKRT1N504 GKRT204 GKRT304 GKRT404 GKRT504

Standarts

Rated Voltage

Rated Current

Rated Power

Rated Frequency

Phase

Impedance

Tolerance of Inductance

Thermal Strength

Linearity

Protection Class

İnsulation Class

Impregnation

Cooling

Ambient Temperature

Humidity

Altitude

Design

Winding

Terminals

TECHNICAL DATA

: TS EN61558-2-20, TS EN60076-6

: CE Conformity

: 230V...400V...600V...1000V

: 4A.................................3000A

: 0,37kW.....................1600kW

: 50Hz

: 1 - 3

: 4% or demanded

: ±5%

: 1,15In continuous

: 1,4In above

: IP00

: F Class 1550C

: H Class Varnish Vacuum Impregnation

: Natural

: 400C

: 95%

: 1000m

: 3 phase, Iron Cored, with air gap

: Copper, Aluminium

: Terminal blocks, Cable lugs or Copper bars

Line-load reactors help to keep your equipment to run longer by absorbing many of the disturbances, especially the spikes coming from the electrical system, which otherwise damage or shut down your inverters, variable speed controllers, or other sensitive equip-ments. They are the modern technological solution to the problems of the inverter and drive applications. They are very e�ective at reducing harmonic distor-tion produced by inverters and drives.

• Decrease the ratio of dv/dt• Decrease peak voltage• Increase the efficiency of the motor• Decrease the noise of the motor• Decrease over heating of the motor• Lengthens the isolation life of the motor

• Decrease the harmonic distortion • Absorb the surges and the spikes• Decrease voltage peaks• Improve the true power factor• Lengthens the operating life of the inverters

THE BENEFITS OF LINE REACTORS THE BENEFITS OF LOAD REACTORS

LINE - LOADREACTORS

Page 2: LINE - LOAD REACTORS...LINE REACTORS DATA SHEET 400V, 3 PHASE, 4% IMPEDANCE 230V, 1PHASE, 4% IMPEDANCE GKRTN3704 GKRTN5504 GKRTN7504 GKRT1N104 GKRT1N504 GKRT204 GKRT304 GKRT404 GKRT504

LINE REACTORS DATA SHEET

400V, 3 PHASE, 4% IMPEDANCE

230V, 1PHASE, 4% IMPEDANCE

GKRTN3704

GKRTN5504

GKRTN7504

GKRT1N104

GKRT1N504

GKRT204

GKRT304

GKRT404

GKRT504

GKRT704

GKRT1104

GKRT1504

GKRT1804

GKRT2204

GKRT3004

GKRT3704

GKRT4504

GKRT5504

GKRT7504

GKRT9004

GKRT11004

GKRT13204

GKRT16004

GKRON3704

GKRMN5504

GKRMN7504

GKRM1N104

GKRM1N504

GKRM2N204

GKRM304

GKRM404

kW

0,37

0,55

0,75

1,1

1,5

2,2

3

4

5,5

7,5

11

15

18,5

22

30

37

45

55

75

90

110

132

160

0,37

0,55

0,75

1,1

1,5

2,2

3

4

V

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

230

230

230

230

230

230

230

230

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

1

1

1

1

1

1

1

1

A

1,5

2

2,5

3

4

6

8

10

12

16

25

35

40

50

63

80

100

110

160

200

220

260

320

4

6

8

10

12

20

25

30

mH

20

15

12

10

7,4

4,9

3,7

3,0

2,4

1,84

1,20

0,84

0,73

0,59

0,47

0,37

0,29

0,27

0,18

0,15

0,13

0,11

0,092

8

5

4

3

2,5

1,5

1,2

1

mm

120 x 130 x 70

120 x 130 x 70

120 x 130 x 75

120 x 130 x 70

120 x 130 x 70

120 x 130 x 80

120 x 130 x 80

150 x 150 x 85

150 x 150 x 80

150 x 150 x 100

150 x 180 x 100

180 x 215 x 120

180 x 225 x 125

180 x 160 x 130

240 x 205 x 140

240 x 210 x 150

240 x 210 x 160

260 x 210 x 170

300 x 260 x 170

300 x 260 x 185

300 x 260 x 200

300 x 260 x 210

360 x 305 x 210

84 x 100 x 75

84 x 100 x 80

84 x 100 x 80

96 x 120 x 95

96 x 110 x 95

95 x 110 x 90

96 x 105 x 120

96 x 100 x 120

CODE POWER VOLTAGE PHASE CURRENT INDUCTANCE DIMENSIONSW x H x D

Reactors up to 3000A are available

w

W

H

D

d

LINE - LOADREACTORS

Page 3: LINE - LOAD REACTORS...LINE REACTORS DATA SHEET 400V, 3 PHASE, 4% IMPEDANCE 230V, 1PHASE, 4% IMPEDANCE GKRTN3704 GKRTN5504 GKRTN7504 GKRT1N104 GKRT1N504 GKRT204 GKRT304 GKRT404 GKRT504

LOAD REACTORS DATA SHEET

400V, 50Hz, 3 PHASE

230V, 50Hz, 3PHASE

MKRT1N1

MKRT1N5

MKRT2

MKRT3

MKRT4

MKRT5

MKRT7

MKRT11

MKRT15

MKRT18

MKRT22

MKRT30

MKRT37

MKRT45

MKRT55

MKRT75

MKRT90

MKRT110

MKRT132

MKRT160

MKRMN75

MKRM1N1

MKRM1N5

MKRM2

V

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

230

230

230

230

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

kW

1,1

1,5

2,2

3

4

5,5

7,5

11

15

18,5

22

30

37

45

55

75

90

110

132

160

0,75

1,1

1,5

2,2

A

3

4

6

8

10

12

16

25

35

40

45

63

80

100

110

160

200

220

260

320

4

6

8

10

mH

4

3

2,4

1,5

1,4

1,2

0,9

0,55

0,40

0,35

0,30

0,24

0,18

0,15

0,12

0,09

0,07

0,06

0,05

0,04

2

1,7

1,2

1,0

mm

120 x 130 x 75

120 x 135 x 75

120 x 130 x 80

120 x 130 x 80

150 x 150 x 90

150 x 155 x 85

150 x 180 x 90

150 x 180 x 95

180 x 160 x 105

180 x 155 x 120

180 x 160 x 130

240 x 210 x 145

240 x 210 x 155

240 x 210 x 160

240 x 210 x 160

300 x 260 x 180

300 x 260 x 190

300 x 260 x 200

300 x 255 x 200

360 x 310 x 200

120 x 130 x 70

120 x 130 x 70

120 x 130 x 80

120 x 130 x 80

CODE VOLTAGE PHASE MOTORPOWER CURRENT INDUCTANCE DIMENSIONS

W x H x D

Reactors up to 3000A are available

w

W

H

D

d

LINE - LOADREACTORS