Upload
others
View
14
Download
1
Embed Size (px)
Citation preview
P O W E R E D B Y S P E C I A L I S T S
LIGHTRAK®
LIGHTING CONTROL SYSTEMPRODUCT GUIDE
LEGRAND’S POWER DISTRIBUTION BUSINESS UNIT
From Zucchini transformers, through high
power distribution and rising main busbar to
Electrak powertrack, desk modules and lighting
control, Legrand’s power distribution business
unit provides market leading solutions to the
increasing demands of today’s buildings.
Legrand is the global specialist in
electrical and digital building
infrastructures. Innovation is the
driving force behind its development.
With an increasing investment in research and
development (circa 5% of sales) and more than
4,000 active patents, the Legrand Group is focused
on maintaining a high rate of new product launches
that present innovative solutions to the market.
built on localknowledge
Global strength
CSRUSERS- Provide sustainable solutions- Play a driving role in
the electrical sector
SOCIETY- Act ethically- Ensure responsible purchasing- Enable access to electricity for all
EMPLOYEES- Respect human rights- Guarantee health and safety at work- Develop skills and promote diversity
ENVIRONMENT- Reduce the Group’s
environmental footprint- Innovate for a circular
economy
CORPORATE SOCIAL RESPONSIBILITY
Legrand’s CSR roadmap is a natural extension
to the governance and sustainable development
approach in which the company has been
engaged for many years. The CSR roadmap
firmly asserts Legrand’s ongoing commitment
to sustainable development.
1
CO
NTE
NTS
LEGRAND ENERGY EFFICIENCYLegrand is a capable and reliable supply partner that:
• delivers innovation
• offers market leading low carbon solutions
• delivers very high standards of corporate responsibility
Legrand has long been committed to an initiative to protect the environment. This commitment
concerns both the Group's sites and the life cycle of products, from their design to the end of
their life. As a world-leading specialist in electrical and digital infrastructures for buildings,
Legrand is dedicated to ensuring that everyone can use electricity in a sustainable way.
By working together we can create solutions that deliver less carbon to the environment.
LIGHTRAK
Overview 6
Ordering information 14
Technical information 16
BUSCOM
Overview 4
Ordering information:
Intelligent busbar system 22
Electrak 30-33 systems 24
Technical information 38
INTRODUCTION
Electrak the specialist in power distribution throughout the workplace 2
2
ELECTRAK® the specialist in power distribution throughout the
workplace
Electrak, a brand of the Legrand
Group in the UK, is a leading
name in power distribution and
lighting control solutions.
Electrak busbar systems, floor boxes, floor
grommets, desk modules and lighting control
ranges are installed in high specification offices
around the world.
3
UNDERFLOOR POWER
Electrak’s powertrack system is perfect for
supplying underfloor power in cavity floor
installations. With minimal parts, push fit
assembly and a complementary range of floor
boxes, this flexible, easy-to-install system can
be reconfigured as office layouts evolve.
Powering the
workplace
POWERTRACK
BUSCOM
power and data backbone
See page 24
CAVITY FLOOR BOXES
LIGHTRAK
lighting control system
See page 14
FULLY ADDRESSABLE
LIGHTING CONTROL
Designed to work in harmony with Buscom
trunking, Lightrak lighting control offers
high-end sophistication with unbeatable
flexibility and speed of installation.
FLOOR GROMMETS INTERSOC-R INTERSOC ON-DESK
WORKSTATION POWER
Electrak’s access grommets provide the gateway
for power to feed from the underfloor powertrack
network to the workstation, where all desk power
requirements are met with our new range of desk
modules, Intersoc-R and Intersoc on-desk.
Buscom trunking a unique power and data backbone
Buscom is at the heart of Electrak’s lighting control solutions...
distributing both power and communications within a single busbar
trunking system, it provides a flexible and simple alternative to
traditional wiring installations.
THE HEART OF YOUR LIGHTING
CONTROL SYSTEM
Installing a matrix of Buscom trunking in the ceiling
void creates an accessible power and communications
backbone. The backbone can be tapped into at any point
to facilitate instant connection to power and control
circuits. Buscom incorporates a shielded twisted pair
communications bus, and is suitable for use with any
lighting control protocol.
MODULAR. FLEXIBLE. SIMPLE.
Trunking lengths simply push-fit together, saving time
and money on installation. With cable terminations only
required for power and control circuits in the feed unit,
Buscom delivers an adaptable and robust plug and play
solution that allows for future lighting layout changes
to be made quickly and efficiently, whilst drastically
reducing the potential points of failure in comparison
with traditional wiring methods.
• Power and communications within a single
trunking system
• Suitable for use with: KNX, LonWorks,
DALI and more
• Fast to install, easy to adapt
• Robust system with minimal potential points
of failure
Buscom is available in many different configurations, meaning separate circuits can be available for many different requirements like lighting, HVAC, comms bus, DALI etc.
The installation time of Buscom is
comparable to installing a cable
containment system, but with Buscom
the job of pulling, prepping and
terminating the cables is already done,
saving a considerable amount of time.
Examples of power only configurations
Introducing a KNX bus Introducing a DALI bus
Buscom also uniquely incorporates a
shielded twisted pair meaning a bus
connection (e.g. KNX) can be available at
every tap-off outlet, making it perfect for
networked lighting control installations.
Live 1
Neutral 1
Live 3
Live 2
Live 1
Neutral
Live 1
Neutral 1
Neutral 2
Live 2
Neutral 3
Live 3
Neutral 4
Live 4
Live 2
Neutral 2
Live 1
Neutral 1
Buscom can even be configured to incorporate a DALI
bus as well as KNX, providing the perfect solution for
DALI lighting control over a KNX backbone. There is also
the option for a second electrical circuit dedicated to
mechanical power supply.
KNX Bus
Live 2
Neutral 2
Live 1
Neutral 1
KNX Bus
DALI + ive
DALI - ive
Live
Neutral
KNX Bus
DALI + ive
DALI - ive
Live 1
Neutral 1
Neutral 2
Live 2
5
6
Lightrak®
a uniquely adaptable lighting control systemDesigned to work in harmony with Electrak’s Buscom trunking,
Lightrak lighting control systems offer high end sophistication
with unbeatable flexibility and speed of installation.
PLUG AND PLAY With Lightrak, lighting control modules come
pre-wired with tap-offs and pre-fitted with brackets,
meaning the installation is as simple as snapping on,
and plugging in.
SOPHISTICATED TECHNOLOGY Lightrak offers fully addressable DALI control,
networked over a KNX backbone. The scalability of
KNX enables full building-wide lighting control and
seamless connectivity with KNX devices from over
300 manufacturers.
COMPREHENSIVE RANGE OF
LIGHTING CONTROL DEVICES
Wide ranging offer of energy saving switching,
sensing and scheduling devices. Including infrared,
ultrasonic and microwave detectors offering presence
or absence detection and constant luminance with
daylight linking.
A CONNECTED SYSTEM Lightrak is PC configurable and can be integrated
onto IP or BMS networks meaning lighting installations
can be controlled, tested and monitored either locally,
or remotely via the internet.
7
A CHOICE OF SYSTEM ARCHITECTURES
The new Lightrak KNX/DALI controller has been updated
with the latest electronic components and its size has
been reduced to fit into this neat modular format.
TRADITIONAL LCM SOLUTION:
The modular controller plugs into an eight outlet distribution box,
which creates a KNX/DALI Lighting Control Module (LCM).
INTELLIGENT BUSBAR SYSTEM:
The modular controller plugs into a Buscom Control Unit,
which injects DALI onto the Buscom, creating a KNX/DALI
intelligent busbar system.
Luminaires plug into the LCM via GST leads:
KNX Bus
Live
Neutral
KNX Bus
DALI + ive
DALI - ive
Live
Neutral
Luminaires plug into the intelligent
busbar system via tap-off leads:
EXTRA CAPACITY FOR AN INTELLIGENT BUSBAR
A DALI break interlink can be used to split a DALI
circuit in two, while continuing the power and KNX
circuits. An additional controller can then be added
to double the number of DALI addresses.
A DALI distribution box can be plugged in to turn
one tap-off outlet into eight GST outlets if required.
A range of tee-modules and extender sub-cables is
also available if it is more practical to daisy chain.
into an e g
ighting Control Mod
uscom,
8
ENERGY EFFICIENCY
The Lightrak system operates over a KNX backbone.
This enables all control devices connected to the
system to communicate with each other, and facilitates
seamless interoperability with any KNX certified product.
KNX PROTOCOL SYSTEMS
KNX is the worldwide standard for all applications in
home and building control, ranging from lighting and
shutter control to security, HVAC, metering and energy
management. With more than 370 members, the KNX
Association holds partnership agreements with over
44,000 installer companies in 128 countries. All products
bearing the KNX logo are certified in order to guarantee
system compatibility, interworking and interoperability
and are commissioned via a single, manufacturer
independent design and commissioning tool.
KNX IS APPROVED AS:
• European Standard (CENELEC EN 50090 and
CEN EN 13321-1)
• International Standard (ISO/IEC 14543-3)
For more information about KNX, visit: www.knx.org
Lighting accounts for up to 40% of a commercial building’s electricity use(Lighting Industry Federation)
Lighting controls can provide energy savings of 30% to 55%.
LEFT: KNX was used as the underlying technology at Terminal 5, Heathrow... possibly the largest lighting control installation in Europe
Lightrak®
seamless integration with your technology of choice
9
DELIVERING DALI EMERGENCY
FEEDBACK
The KNX/DALI lighting controller incorporates a KNX to
DALI interface that enables full DALI control in addressable
mode, and also facilitates the feedback from the DALI
network back onto the KNX bus.
Utilising widely available KNX gateways, this DALI feedback
can then be fed into building management systems (BMS)
or other monitoring and reporting software, allowing
emergency lighting test data to be logged and alarms
raised should essential maintenance be required.
DALI FEATURE IMAGE
For more information about DALI, visit: www.dali-ag.org
DALI: DIGITAL LIGHTING CONTROL
DALI (Digital Addressable Lighting Interface) is a
protocol dedicated purely to lighting control, as set
out in the technical standard IEC 62386. Each unit in
a DALI network has its own address, allowing direct
communication with each individual fitting.
TECHNICAL FEATURES
The information flow with DALI is bi-directional.
Rather than only giving commands about the light level
from the control system to the fitting, DALI also enables
information feedback on the condition of the fittings.
The fitting can transmit information related to:
• whether the light is switched on or off
• the preset light level
• the ballast condition
Therefore DALI is ideal for use with building automation
systems where remote supervising and service reports
are required.
10
Lightrak takes plug and play adaptability to the next level. Once Buscom
is installed, lighting and control devices just plug in to the nearest outlet.
Should the use or configuration of a space change, components can simply
be unplugged, moved and the system reprogrammed – or additions can be
plugged into the bar as required.
With Lightrak, developers can install a cost-effective lighting control solution
that is adequate for the initial category-A development, but can be upgraded
to meet the category-B needs of incoming tenants with a minimum level of
investment in time and labour.
TRADITIONAL LCM SOLUTION:
Lightrak’s plug and play intelligence
ensures the system is adaptable,
easy to upgrade and future-proof.
Lighting schemes can be completely
reconfigured without the need to run
or terminate any additional circuits.
This example demonstrates just
how easy it is to upgrade a system
from category-A to category-B by
simply moving or plugging in extra
components.
The ability to adaptwith the building throughout its life
NAL LCM
11
INTELLIGENT BUSBAR SYSTEM:
With the Intelligent Busbar System,
the Buscom trunking itself becomes
the lighting control unit. Lights and
control devices plug directly into the
bar via tap-offs. This solution delivers
neat installation with the short
connection cables, enabling full DALI/
KNX control in the most efficient way
possible.
18TH EDITION IET WIRING REGULATIONS BS 7671:2018, the IET Wiring Regulations 18th Edition pushes for better support of cables to prevent
their premature collapse in the event of fire. Regulation 521.10.202 replaces regulation 521.11.201
and extends this requirement beyond escape routes to cables throughout the installation. Busbar
systems drastically reduce the amount of cable used within an installation and can help to comply with
this latest regulation. With the launch of the new Intelligent Busbar System, Lightrak can now deliver
power and control to lighting with even less cable, as being able to plug in anywhere along the bar
means that luminaire connection cables can now be even shorter.
NT
12
supporting you from initial design through installation and beyond
AN OPEN PROTOCOL
KNX is an open protocol meaning lighting control units can either be supplied
unprogrammed for third party system integration, or we can deliver a full in-house
project design and commissioning service. Our experienced team can provide support
at all stages of a project, from the outline brief through to final site commissioning.
Legrand
13
DEDICATED DESIGN TEAM
Designing a Lightrak system is simple but working
with our team of experts can ensure that the Buscom
layout is optimised along with the power and bus
configuration. The team can guide and help you to design
a fully functioning lighting control system proposing the
most efficient solutions for functionality, arrangement
and system architecture.
CONTINUING SUPPORT
Support will continue throughout the project.
KNX commissioning is done in the factory and layout and
schematics drawings are delivered with the system so
the installers know where every component needs to go.
The on-site commissioning team will then be at hand to
finalise the DALI addressing and ensure that the system is
functioning as expected before final sign off.
MANAGING AND MAINTAINING
A graphical headend can be provided for
navigation, visualisation and monitoring of
the lighting and energy usage. Emergency
lighting tests can be scheduled and the results
harvested and logged. Fault statuses will be
visualised and alerts can be systematically sent
to the maintenance team. The headend can be
connected to the internet facilitating local or
remote management and maintenance.
14
Lightrak® KNX / DALI lighting control systemsystem components, lighting control units (LCUs) and sub-cabling to luminaires
Pack Cat. Nos. Lightrak – Sub-cabling for use with LCMs
Luminaire connection leads
1 BVITM6L503100W 6 pole, 5 core, 3 m, 1 mm2, LSF 1 BVITM6L505100W 6 pole, 5 core, 5 m, 1 mm2, LSF 1 BVITM6L508100W 6 pole, 5 core, 8 m, 1 mm2, LSF
Extender leads for daisy chaining
1 BVITM6-L5T500 Tee module 6 pole, 5 core, 0.5 m lead, 1 mm2
1 BVITM6-5-LL-03 Extender lead 6 pole, 5 core, 3 m, 1.5 mm2, LSF
1 BVITM6-5-LL-05 Extender lead 6 pole, 5 core, 5 m, 1.5 mm2, LSF
1 BVITM6-5-LL-08 Extender lead 6 pole, 5 core, 8 m, 1.5 mm2, LSF
Connection plugs for hard wiring
1 BVITM6-LPW 6 pole, male connector 1 BVITM6-LPW-F 6 pole, female connector
Pack Cat. Nos. Lightrak – System components
1 FFA001 Statutory warning plaque
1 FFA004 Timed event controller (flush)
1 FFA006 Timed event controller (surface)
1 FFA020 Line power supply, wall mounted
1 FFA021 Powered line coupler, wall mounted
1 FFA022 Buscom mounted power supply unit
1 FFA024 KNX/IP gateway with router
1 FFA025 KNX to USB interface
1 FFA026 Commissioning tool
1 FFA014 Signal cable 100 m
Connection kit for use with Lightrak commissioning tool
1 FFG350 Power and communications connection kit
Lightrak – KNX/DALI lighting control unit
1 FFD062 Modular KNX/DALI lighting controller
Lightrak – distribution boxes
Distribution boxes for use with FFD062 to
create LCMs
1 FFDDDB DALI distribution box surface mountable (for use without Buscom)
1 FFDDDB1 DALI distribution box with 8 GST outlets Buscom mountable with WHITE tap-off 10 A fused L, N, E + KNX
Buscom control unit for use with FFD062 to
create intelligent busbar
1 FFDBCU DALI Buscom control unit Buscom mountable with BLUE tap-off 10 A fused L, N, E, D + D - KNX
DALI distribution box for use with intelligent
busbar system when extra outlets are
required
1 FFDDDB2 DALI distribution box with 8 GST outlets Buscom mountable with BLUE tap-off 10 A fused L, N, E D + D - KNX
Lightrak – Graphical headend and emergency lighting monitoring centre
1 HEADEND Project bespoke solution
Proprietory lighting control system to work alongside Electrak’s 25 and 40 A Buscom trunking with integral communications busOffers high speed installation and unrivaled flexibility for future reconfiguration. PC configurable and integratable Based on the KNX open protocol and compatible with DALI lighting installations Designed and manufactured in the UK
Modular KNX/DALI lighting controller
FFD062
Dimensions and technical information p. 16-21
DALI distribution
box
FFDDDB1
Powered line coupler
FFA021
DALI Buscom
control unit
FFDBCU
Connection plug for hard wiring - 6 pole,
male connector
BVITM6-LPW
Connection plug for hard wiring - 6 pole,
female connector
BVITM6-LPW-F
15
Lightrak® KNX / DALI lighting control systemsensors and switching devices
Pack Cat. Nos. Lightrak – Switching devices
KNX Arteor devices
1 0784 95 Single switch
1 0784 96 Double switch
1 5742 03 4 button scenario switch 1 0784 93 Wall mounting sensor
Arteor surround plates
1 7300 92 White surround plate 1 gang – 2 modules
1 7300 94 White surround plate 2 gang – 4 modules
1 8330 92 Brushed stainless steel surround plate 1 gang – 2 modules
1 8330 94 Brushed stainless steel surround plate 2 gang – 4 modules
Zigbee/KNX wireless devices
1 0784 61 White wireless switch – 1 button - 2 actuation points
1 0488 77 Zigbee/KNX interface
1 0883 09 Zigbee wall mounting sensor
Other switching devices
1 7354 14 Synergy grid 2 way retractive switch
1 7354 16 Synergy grid 2 way key switch
1 7301 91 Synergy grid front plate 1 gang – white
1 8331 91 Synergy grid front plate 1 gang – brushed stainless steel
1 7354 90 Synergy grid support frame
KNX switching devices connect into the system via KNX tap-off straight into the Buscom systemThe KNX system is fully addressable and can be commissioned to control any output or group of outputs throughout the entire KNX networkFuture layout changes can be accommodated easily as all components are plug and play and can be re-commissioned through KNX ETS software
Pack Cat. Nos. Lightrak – KNX sensors
Ceiling mounted sensors
1 FFC060 Compact PIR detector KNX – flush mounting
1 FFC061 Microwave detector KNX – low profile
1 0489 61 Microwave detector KNX – adjustable head
1 0489 60 High bay PIR detector KNX
Handsets for use with sensors (above)
1 UHS5 Commissioning handset
1 UHS7 User handset
Combined PIR and ultrasound detectors
1 0489 18 Ceiling mounting dual tech sensor KNX
1 0489 20 Wall mounting dual tech sensor KNX
Handsets for use with combined PIR and ultrasound detectors (above)
1 0882 30 Commissioning handset
Mounting accessories for use with sensors
1 MWS3A-DBB Surface mounting back box for Cat. No. 0489 61
1 DBB Surface mounting back box for Cat. Nos. FFC060 and FFC061
1 0488 75 Surface mounting back box for Cat. No. 0489 18
1 0489 71 Corner accessory for Cat. No. 0489 20
Lightrak – Sub-cabling for use with KNX devices
1 FFG300 5 m tap-off – KNX only
1 FFG305 10 m tap-off – KNX only
Dimensions and technical information p. 16-21
Commissioning
handset
0882 30
Compact PIR
detector KNX -
flush mounting
FFC060
Microwave
detector KNX -
adjustable head
0489 61
Microwave
detector KNX -
low profile
FFC061
Ceiling mounting
dual tech sensor
0489 18
Wall mounting
dual tech sensor
0489 20
Commissioning
handset for FFC
sensors
UHS5
16
Lightrak® KNX / DALI lighting control systemtechnical information
KNX technical specification
Each line coupler can support 64 KNX bus devicesA maximum of 15 line couplers may be linked with a main bus line together to form an area; therefore an area can support up to 960 devicesThe system may be further expanded with the addition of a backbone bus line which would allow the linking together of 15 main bus lines via 15 line couplers, therefore any single system could support 14 400 devicesBy utilising additional line couplers this total can exceed 64 000 devices (for additional information, please contact us on +44 (0) 370 608 9020)
Within any KNX bus line the following cable lengths are permitted :• Power supply unit to bus device 350 m maximum• Bus device to bus device 700 m maximum• Total bus line length 1 000 m maximum• Minimum distance between 2 power supply units on one line is 200 m • A Buscom trunking mounted power supply unit can be used for this application, Cat. No. FFA022
KNX power supply - 640 mA found within :
• Cat. No. FFA020 – Line power supply • Cat. No. FFA021 – Powered line coupler • Cat. No. FFA022 – Buscom mounted power supply unit • Cat. No. FFA024 – KNX/IP gateway with router
KNX power supply produces and monitors KNX system voltage The bus line is decoupled from the power supply with the integrated choke
Cat. No. FFA021 - Powered line coupler, wall mounted
Device links the data on two different bus/KNX lines and isolates bus lines from one another to allow independent local operation on a bus lineLine coupler can be used as a : • Line coupler • Zone coupler • Or a repeater on either existing bus networks or new bus/KNX networks
KNX/bus power supply
• Primary line 29 V• Secondary line 29 V
KNX/bus absorption
• From the primary line 6 mA • From the secondary line 8 mA
Electrical safety
• Degree of pollution (in accordance with CEI 60664-1) : 2 • Protection type (in accordance with EN 60529) : IP 20 • Protection class (in accordance to IEC 61140): III • Overvoltage class (in accordance to IEC 60664-1): III • Bus : safety extra-low voltage SELV DC 24 V • Device complies with EN 50090-2-2 and EN 60669-2 EMC requirements comply with EN 61000-6-1, EN 61000-6-3 and EN 50090-2-2
Marking
• KNX, CE
All dimensions (mm) are nominal
Electrical features
Power supply Input voltage: 110-250V~, 50-60Hz
Power loss < 6 W
Efficiency 75%
Output KNX output (DPSU): 1 line with
integrated choke
KNX nominal voltage 29 V DC +2/-1 V, SELV
Auxiliary voltage output 1 (without choke)
Auxiliary voltage 29 V DC +2/0 V, SELV
KNX nominal current (Total of KNX and auxiliary
voltage output)
640 mA, short-circuit proof
Sustained short-circuit current < 1.3 A
Mains failure back-up time > 200 ms
17
Cat. No. FFA025 - USB/KNX interface
Device is used to connect a PC to the KNX/bus in order to address, configure, display, connect and perform diagnostics on bus devices via the USB portIt allows access to products on the bus in accordance with KNX protocol
Technical features
• Supply voltage via USB connected to PC• USB connection USB type B (maximum length 5 m, cable not supplied)• Transmission speed 9 600 bps between the interface and the bus12 Mbps between the USB 1.1 interface and the PC
Standards
• Directive : CE• Installation standards : NFC 15-100• Product standards : IEC 60669-2-1• Environmental standards : - EU Directive 2002/96/EC : WEEE (Waste Electrical and Electronic Equipment) - EU Directive 2002/95/EC : RoHS (Restriction of Hazardous Substances) - Decrees and/or regulations : ERP (public buildings), ERT (workplace buildings), IGH (high-rise buildings)
Enclosure dimensions
Enclosure technical details
• Self-extinguishing : resistance to incandescent wire 650°C• Conforms to EN 60439-3• Weatherproof enclosures – IP 65 - IK 09 - Class II• Door and enclosure fully reversible• Lockable door handle, sealable cover and faceplate• Shock-resistant polystyrene material• Box colour light grey L750A, cover colour dark grey R746A
Lightrak® KNX / DALI lighting control systemtechnical information (continued)
All dimensions (mm) are nominal
A
48.5
78
C D
B
E
Cat. Nos. Dimensions
A B C D E
FFA020 115·6 164 200 120 70
FFA021 115·6 200 200 120 106
FFA022(1) 115·6 164 200 120 70
FFA024 115·6 200 200 120 106
FFA025 109 93 174 94 -
(1) Dimensions for tap-off and brackets are not included
Cat. No. FFA024 - KNX/IP gateway with router
The KNX/IP router is used to connect several KNX lines via computernetworks using IP (Internet Protocol). Device also offers the benefitof simultaneous access to the bus line from a PC, tablet or smartphone
Equipped with an RJ 45 socket so it can be connected to the computernetwork, and a KNX connector for connection to the KNX bus, thisrouter can be accessed locally via the LAN or remotely
Climatic features
• Environmental operating temperature : -5 to + 45°C• Storage temperature : -25 to + 70°C• Relative humidity (non-condensing) : 5% to 93%• Weight : 105 g
Electrical features
• KNX/bus power supply : 29 V =• Auxiliary power supply: - PoE (Power over Ethernet) 48 V= (in accordance with standard IEEE 802.3af ) max. 0.8 W - external power supply 24 V~/= (12 - 24 V~, 12 - 30 V=) max. 1.7 W (57 mA in 24 V=)
Caution : we recommend using an external safety extra low voltagefor the IP router only
Electricity consumption
• 10 mA KNX/BUS absorption• Auxiliary power supply : max. 1·7 W (57 mA in 24 V=)
Network communication
• Ethernet : 10BaseT (10 Mbps)• Internet protocols supported : ARP, ICMP, IGMP, UDP/IP, DHCP, AutoIP• KNXnet/IP depending on the characteristics of the KNX system : core,routing, device management
Standards and approvals
Electrical safety
• Degree of pollution (in accordance with standard IEC 60664-1) : 2• Protection (in accordance with standard EN 60529) : IP 20• Protection class (in accordance with standard IEC 61140) : III• Overvoltage class (in accordance with standard IEC 60664-1) : III• Bus : safety extra low voltage (SELV) 24 VDC• The device complies with standard EN 50 090-2-2
Electromagnetic compatibility
Compliance with standards EN 61000-6-2, EN 61000-6-3 and EN 50090-2-2
Marking
KNX, EIB, CE
Electromagnetic compatibility
Compliance with EMC regulations (residential and commercial buildings) and low voltage regulations
18
Lightrak® KNX / DALI lighting control systemtechnical information (continued)
All dimensions (mm) are nominal
Cat. No. FFD062 DALI/KNX Lighting Control Module
Cat. No. FFD062 is a lighting control module (LCM) designed for
controlling 32 addressable DALI control gear for lighting which might
include up to 8 emergency controllers
The LCM has 9 male GST style connections for the mains, DALI and
KNX bus. This unit is designed to be used in conjunction with Legrand’s
lighting power and control busbar systems
System wiring example
• Traditional LCM solution • Cat. No. FFDDDB1 distribution box + Cat. No. FFD062 controller
• Distribution box, snap-fits onto the busbar trunking, and plugs in via a
tap-off
• KNX/DALI controller plugs into the end of the distribution box forming
a traditional LCM
• Power comes from the busbar trunking (L, N + E busbars)
• KNX connection is via the comms bus within the busbar trunking
• LCM becomes an individual DALI domain, networked on the wider
KNX bus
• DALI luminaires plug into the LCM to connect to power and DALI
- Distribution box has 8 outlets, 6-pole GST connectors
(L, N, E, D+, D-) black/blue
• KNX sensors and other devices plug into the busbar trunking for
connection to the KNX bus
Cat. No. FFD062 DALI/KNX Lighting Control Module (continued)
System wiring example
• Intelligent busbar solution
• Cat. No. FFDBCU starter unit + Cat. No. FFD062 controller
• Starter unit, snap-fits onto the busbar trunking, and plugs in via a
tap-off
• KNX/DALI controller plugs into the end of the starter unit
• Power comes from the busbar trunking (L, N + E busbars)
• KNX connection is via the comms bus within the busbar trunking
• KNX/DALI controller injects DALI onto a dedicated pair of busbars
within the trunking, turning the busbar run into an individual DALI
domain (Intelligent busbar solution)
DALI luminaires plug into the intelligent busbar via a tap-off for power
and DALI connection
- Tap-off outlets will typically be available at 500 mm intervals
along the entire busbar run
• KNX sensors and other devices plug into the busbar trunking for
connection to the KNX bus
DALI lighting and emergency control gear combinations
The total number of DALI control gear that the LCM is designed to
control is 32. Up to 8 of these can be emergency control gear
The following combinations are given as an example :
• 32 lighting control gear and 0 emergency control gear
• 31 lighting control gear and 1 emergency control gear
• 30 lighting control gear and 2 emergency control gear
• ***
• 24 lighting control gear and 8 emergency control gear
Comms bus
Live
Neutral
Busbar configuration
Comms bus
DALI
DALI
Live
Neutral
Busbar configuration
Neutral
Live
Neutral
Cat. No. FFDDDB1
Cat. No. FFD062Cat. No. FFD062
Cat. No. FFDBCU
19
Lightrak® KNX / DALI lighting control systemtechnical information (continued)
All dimensions (mm) are nominal
Cat. No. FFD062 DALI/KNX Lighting Control Module (continued)
System wiring example (continued)
Technical data
• Weight 0·40 kg
• Supply voltage 220 - 240V AC
• Frequency 50 Hz
• Rated impulse voltage 4 000 V
• KNX voltage 30 V DC via KNX bus
• DALI voltage 16 V DC via DALI
• DALI output current 250 mA (maximum)
• Temperature -10ºC to 35ºC
• Humidity 5 to 95% non-condensing
• Material (casing) flame retardant ABS and PC/ABS
• Classifications
- Insulation : Class II
- Purpose : operating control
- Type : 1.B
- Software class : Class A
- Pollution : Degree 2
• Compliance EMC-2014/30/EU
LVD-2014/35/EU
Dimensions
Dimensions of distribution boxes Cat. Nos. FFDDDB, FFDDDB1 and
FFDDDB2
Allow 150 mm for total height of unit (including cables)
Dimension of tap-offs and brackets not included
Material (casing) flame retardant ABS and PC/ABS
Cat. No. FFD062 DALI/KNX Lighting Control Module (continued)
System wiring example (continued)
Dimensions
Dimensions of Buscom Control Unit Cat. No. FFDBCU
Dimension of tap-offs and brackets not included
Material (casing) flame retardant ABS and PC/ABS
55
95
396
350
200
127
146
159
105
127
145
20
■ PIR presence detectors KNX Cat. No. FFC060
Cat. No. FFC060 is a compact PIR detector suitable to be mounted
either flush or in a surface mounting box
Key Product Features :
• Two ELV switch inputs to manually override the dimming levels and / or
override the lights on or off
• KNX programming mode accessible with IR handset and also by
using the push switch on the back of the unit
• Programmable logic block. This allows conditions to be set.
For example : send the occupancy telegram only if the switch is
pressed and the lux is low
• All functionality is fully programmable using the KNX ETS
commissioning software
Technical Data :
• Control method KNX
• IP rating 40
• Weight 0.15 kg
• Supply voltage DC 30 V DC over KNX bus
• Terminal capacity KNX : 1.2 mm² over KNX connector
Switch input : 2.5 mm²
• Working temperature range °C -10 to 35
• Humidity 5 to 95% non-condensing
• Material (casing) flame retardant ABS and PC/ABS
• Insulation class Class II
• Compliance EMC-2014/30/EU, LVD-2014/35/EU
Detection pattern
Dimensions (mm)
7 m
2.8
m
76 654
HIGH < SENSITIVITY > LOW
Lightrak® KNX / DALI lighting control systemtechnical information (continued)
21
KNX system topology schematic diagram
Example of typical layout
1.15.0 (maximum)
1.5.64
Repeaterpower linecoupler
1.5.128 1.5.192(maximum)
KNX standardbus cable
Bus lin
e(m
ax. 64 L
CU
)
KNX standard bus cable interconnectingmain line powered line coupler
AREA 2 main bus line
AREA 3 main bus line
AREA 4 main bus line
AREA 15 main bus line (maximum)
1.5.01.4.01.3.01.2.01.1 .0
AREA 1 main bus line
Bus lin
e(m
ax. 64 L
CU
)
Backbonepoweredline coupler
1.0. –1.0.1 1.0.2 1.0.3 1.0.4 1.0.15
Backbone bus line
KNX standard bus cableinterconnecting backbonepowered line coupler
Main linepoweredline coupler
Backbonepower supply unit
Lightrak® KNX / DALI lighting control systemtypical layout and system topology
All dimensions (mm) are nominal
22
Electrak® Intelligent lighting busbar systempower, DALI and KNX distribution system
The intelligent lighting busbar system brings together a plug-and-play distribution solution for power, DALI and KNX This innovative new concept delivers a solution where all control and lighting devices plug directly into the tap-off outlets, resulting in a neat professional installation with shortened final cable runs to luminaires With tap-off outlets located every 500 mm along the busbar, it enables the most rapid installation and reconfiguration potential Should extra outlets be required a DALI distribution box can be plugged in, to turn one outlet into 8 additional outlets
Key : How to select the correct components All examples on this page show IP 4X products IP rating is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5
BDA14LFC
BDA14RFC
(1) Weights shown are for IP 4X rated products. For all other
weights, contact us on +44 (0) 845 600 6266
Pack Cat. Nos. Flexible lengths for single sided system
Flexible lengths can be used to change direction, change level or overcome obstructions
Suspended – right to left Length Rating Weight (m) (A) (kg)(1)
1 BDA140XC 0·5 25 3·17 1 BDA142XC 2 25 3·59 1 CDA140XC 0·5 40 3·22 1 CDA142XC 2 40 3·79
DALI break interlink to split DALI domains
For use to continue power and KNX, but split a run into 2 separate DALI domains
Suspended – right to left Length Rating Weight (m) (A) (kg)(1)
1 BBA140XC 0·5 25 2·91 1 CCA140XC 0·5 40 2·94
Pack Cat. Nos. Single sided – Intelligent busbar system
L, N, D+, D- + KNX bus. IP 4X Tap-off outlets are located at 500 mm intervals and colour coded blue to indicate DALI system on just 1 side of the bar
L, N, D+, D- + KNX bus. trunking lengths
Length Tap-off Weight 25 A (m) outlets (kg)(1)
1 BDA2145C 2 4 3·47 1 BDA3145C 3 6 4·77 40 A 1 CDA2145C 2 4 3·61 1 CDA3145C 3 6 4·97
Feed units for single sided system
Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop
Suspended Weight (kg)(1)
1 BDA14LFC 25 A left 1·29 1 BDA14RFC 25 A right 1·52 1 CDA14LFC 40 A left 1·38 1 CDA14RFC 40 A right 1·61
Dimensions and technical information p. 38-43
BDA14LFCBDA3145C
FFDBCU (p. 14)DDD435 (p. 23)
FFD062 (p. 14)
23
Electrak® Intelligent lighting busbar systempower, DALI and KNX distribution system
Pack Cat. Nos. Double sided – Intelligent busbar system
L, N, D+, D- + KNX bus. on the front side and L, N on the back. IP 4X Tap-off outlets are located at 500 mm intervals Outlets on the front / lighting side of the bar are colour coded blue to indicate DALI system Outlets on the back / mechanical side of the bar are colour coded white for power only
L, N, D+, D- + KNX bus. trunking lengths Double sided power only on the rear side
Length Tap-off Weight 25 A (m) outlets (kg)(1)
1 BDA2245C 2 7 3·72 1 BDA3245C 3 11 5·16 40 A 1 CDA2245C 2 7 4·45 1 CDA3245C 3 11 5·46
Feed units for double sided system
Double sided feed units come with 2 x 25 mm Ø cable entry holes for each side of the bar, plus a further 2 x 16 mm Ø. holes for the comms side of the bar
Single screw cable terminals are provided for power and data. Supplied with end stops
Suspended Weight(kg)(1)
1 BDA24LFC 25 A left 1·35 1 BDA24RFC 25 A right 1·61 1 CDA24LFC 40 A left 1·49 1 CDA24RFC 40 A right 1·71
Flexible lengths for double sided system
Flexible lengths can be used to change direction, change level or overcome obstructions
Suspended – right to left Length Rating Weight (m) (A) (kg)(1)
1 BBD240XC 0·5 25 3·16 1 BBD242XC 2 25 4·14 1 CCD240XC 0·5 40 3·63 1 CCD242XC 2 40 4·86
The intelligent lighting busbar system brings together a plug-and-play distribution solution for power, DALI and KNX The double-sided version introduces a second electrical circuit that can be dedicated, for example, for mechanical power. This innovative new concept delivers a solution where all control and lighting devices plug directly into the tap-off outlets, resulting in a neat professional installation with shortened final cable runs to luminaires With tap-off outlets located every 500 mm along the busbar, it enables the most rapid installation and reconfiguration potential Should extra outlets be required a DALI distribution box can be plugged in, to turn one outlet into 8 additional outlets
Pack Cat. Nos. DALI break interklink to split domains
For use to continue power and KNX, but split a run into 2 separate DALI domains
Suspended – right to left Length Rating Weight (m) (A) (kg)(1)
1 BBA240XC 0·5 25 3·14 1 CCA240XC 0·5 40 3·25
DALI tap-off units
16 A unfused tap-offs 2P + E + DALI blue 5 core 1·5 mm2 flex – IP 4X
Length (m)
1 DDD435 3 1 DDD455 5 1 DDD485 8
5 A fused tap-offs 2P + E + DALI blue 5 core 1·5 mm2 flex – IP 4X
Length (m)
1 DDD435F 3 1 DDD455F 5 1 DDD485F 8
16 A unfused tap-offs to 6P GST female connector 2P + E + DALI blue 5 core 1·5 mm2 flex – IP 4X
Length (m)
1 DDD435G 3 1 DDD455G 5 1 DDD485G 8
5 A fused tap-offs to 6P GST female connector 2P + E + DALI blue 5 core 1·5 mm2 flex – IP 4X
Length (m)
1 DDD435FG 3 1 DDD455FG 5 1 DDD485FG 8
DALI only tap-offs, blue 2 core 1·5 mm2 flex – IP 4X
Length (m)
1 DDD432 3 1 DDD452 5 1 DDD482 8
CCA240XC
(1) Weights shown are for IP 4X rated buscom. For all other
weights, contact us on +44 (0) 845 600 6266
Key : How to select the correct components All examples on this page show IP 4X products IP rating and tap-off type is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5
Dimensions and technical information p. 38-43
CDA3245C
CDA2245C
24
Electrak® Buscom trunking2P, 3P, dual circuit and 3 phase systems
3 m track 0·5 m spacings
2 m track 0·5 m spacings
3 m track 1·0 m spacings
2 m track 1·0 m spacings
Single sided BBA3145C BBA2145C BBA3141C BBA2141C
Double sided BBA3245C BBA2245C BBA3241C BBA2241C
Single sided CCA3145C CCA2145C CCA3141C CCA2141C
Double sided CCA3245C CCA2245C CCA3241C CCA2241C
Single sided BBA3155C BBA2155C BBA3151C BBA2151C
Double sided BBA3255C BBA2255C BBA3251C BBA2251C
Single sided CCA3155C CCA2155C CCA3151C CCA2151C
Double sided CCA3255C CCA2255C CCA3251C CCA2251C
Single sided BBB3145C BBB2145C BBB3141C BBB2141C
Double sided BBB3245C BBB2245C BBB3241C BBB2241C
Single sided CCB3145C CCB2145C CCB3141C CCB2141C
Double sided CCB3245C CCB2245C CCB3241C CCB2241C
Single sided BBB3155C BBB2155C BBB3151C BBB2151C
Double sided BBB3255C BBB2255C BBB3251C BBB2251C
Single sided CCB3155C CCB2155C CCB3151C CCB2151C
Double sided CCB3255C CCB2255C CCB3251C CCB2251C
Single sided BBC3145C BBC2145C BBC3141C BBC2141C
Double sided BBC3245C BBC2245C BBC3241C BBC2241C
Single sided CCC3145C CCC2145C CCC3141C CCC2141C
Double sided CCC3245C CCC2245C CCC3241C CCC2241C
Single sided BBC3155C BBC2155C BBC3151C BBC2151C
Double sided BBC3255C BBC2255C BBC3251C BBC2251C
Single sided CCC3155C CCC2155C CCC3151C CCC2151C
Double sided CCC3255C CCC2255C CCC3251C CCC2251C
Single sided BBD3145C BBD2145C BBD3141C BBD2141C
Double sided BBD3245C BBD2245C BBD3241C BBD2241C
Single sided CCD3145C CCD2145C CCD3141C CCD2141C
Double sided CCD3245C CCD2245C CCD3241C CCD2241C
Single sided BBD3155C BBD2155C BBD3151C BBD2151C
Double sided BBD3255C BBD2255C BBD3251C BBD2251C
Single sided CCD3155C CCD2155C CCD3151C CCD2151C
Double sided CCD3255C CCD2255C CCD3251C CCD2251C
Electrak 302P + E system
SYSTEM IP RATING RATING
25 A
40 A
25 A
40 A
25 A
40 A
25 A
40 A
IP 54
IP 4X
IP 54
Electrak 313P + E system
OUTLETS
IP 4X
25 A
40 A
25 A
40 A
25 A
40 A
25 A
40 A
Electrak 32Dual circuit system
Electrak 333 phase system
IP 54
IP 4X
IP 54
IP 4X
25
Centre feedSuspended feed
unit left handSuspended feed unit right hand
Surface feed unit left hand
Surface feed unit right hand
Suspended flexible corner
0·5 m
Suspended flexible corner
2·0 m
Surface flexible corner 0·5 m
Surface flexible corner 2·0 m
BBA44FC BBA14LFC BBA14RFC BBA34LFC BBA34RFC BBA140XC BBA142XC BBA340XC BBA342XC
– BBA24LFC BBA24RFC – – BBA240XC BBA242XC – –
CCA44FC CCA14LFC CCA14RFC CCA34LFC CCA34RFC CCA140XC CCA142XC CCA340XC CCA342XC
– CCA24LFC CCA24RFC – – CCA240XC CCA242XC – –
– BBA15LFC BBA15RFC BBA35LFC BBA35RFC BBA150XC BBA152XC BBA350XC BBA352XC
– BBA25LFC BBA25RFC – – BBA250XC BBA252XC – –
– CCA15LFC CCA15RFC CCA35LFC CCA35RFC CCA150XC CCA152XC CCA350XC CCA352XC
– CCA25LFC CCA25RFC – – CCA250XC CCA252XC – –
BBB44FC BBB14LFC BBB14RFC BBB34LFC BBB34RFC BBB140XC BBB142XC BBB340XC BBB342XC
– BBB24LFC BBB24RFC – – BBB240XC BBB242XC – –
CCB44FC CCB14LFC CCB14RFC CCB34LFC CCB34RFC CCB140XC CCB142XC CCB340XC CCB342XC
– CCB24LFC CCB24RFC – – CCB240XC CCB242XC – –
– BBB15LFC BBB15RFC BBB35LFC BBB35RFC BBB150XC BBB152XC BBB350XC BBB352XC
– BBB25LFC BBB25RFC – – BBB250XC BBB252XC – –
– CCB15LFC CCB15RFC CCB35LFC CCB35RFC CCB150XC CCB152XC CCB350XC CCB352XC
– CCB25LFC CCB25RFC – – CCB250XC CCB252XC – –
BBC44FC BBC14LFC BBC14RFC BBC34LFC BBC34RFC BBC140XC BBC142XC BBC340XC BBC342XC
– BBC24LFC BBC24RFC – – BBC240XC BBC242XC – –
CCC44FC CCC14LFC CCC14RFC CCC34LFC CCC34RFC CCC140XC CCC142XC CCC340XC CCC342XC
– CCC24LFC CCC24RFC – – CCC240XC CCC242XC – –
– BBC15LFC BBC15RFC BBC35LFC BBC35RFC BBC150XC BBC152XC BBC350XC BBC352XC
– BBC25LFC BBC25RFC – – BBC250XC BBC252XC – –
– CCC15LFC CCC15RFC CCC35LFC CCC35RFC CCC150XC CCC152XC CCC350XC CCC352XC
– CCC25LFC CCC25RFC – – CCC250XC CCC252XC – –
BBD44FC BBD14LFC BBD14RFC BBD34LFC BBD34RFC BBD140XC BBD142XC BBD340XC BBD342XC
– BBD24LFC BBD24RFC – – BBD240XC BBD242XC – –
CCD44FC CCD14LFC CCD14RFC CCD34LFC CCD34RFC CCD140XC CCD142XC CCD340XC CCD342XC
– CCD24LFC CCD24RFC – – CCD240XC CCD242XC – –
– BBD15LFC BBD15RFC BBD35LFC BBD35RFC BBD150XC BBD152XC BBD350XC BBD352XC
– BBD25LFC BBD25RFC – – BBD250XC BBD252XC – –
– CCD15LFC CCD15RFC CCD35LFC CCD35RFC CCD150XC CCD152XC CCD350XC CCD352XC
– CCD25LFC CCD25RFC – – CCD250XC CCD252XC – –
26
Ele
ctr
ak
30
2P
+ E
sy
ste
mS
YS
TE
M
PH
AS
E
IP R
AT
ING
L+
N
IP 54
IP 4X
Ele
ctr
ak
31
3P
+ E
sy
ste
m
Ele
ctr
ak
32
Du
al
cir
cu
it s
ys
tem
L1
NL
1 L
2 N
IP 54
IP 4X
IP 54
IP 4X
L1
N1
L2
N2
IP 54
IP 4X
IP 54
IP 4X
L1
NL
2 N
IP 54
IP 4X
IP 54
IP 4X
L3
NP
ha
se
s
ele
cta
ble
IP 54
IP 4X
IP 54
IP 4X
L +
L +
L +
N
IP 54
IP 4X
Electrak® Buscom trunking tap-offs
Rewirable 0·8 m 2 m 3 m 5 m
With comms – DDE408FC DDE42FC DDE43FC DDE45FC
No comms DDF4F DDE408F DDE42F DDE43F DDE45F
With comms – DDE508FC DDE52FC DDE53FC DDE55FC
No comms DDF5F DDE508F DDE52F DDE53F DDE55F
With comms – DDE408FC DDE42FC DDE43FC DDE45FC
No comms DDF4F DDE408F DDE42F DDE43F DDE45F
With comms – DDE508FC DDE52FC DDE53FC DDE55FC
No comms DDF5F DDE508F DDE52F DDE53F DDE55F
With comms – DDG408FC DDG42FC DDG43FC DDG45FC
No comms DDH4F DDG408F DDG42F DDG43F DDG45F
With comms – DDG508FC DDG52FC DDG53FC DDG55FC
No comms DDH5F DDG508F DDG52F DDG53F DDG55F
With comms – DDE408FC DDE42FC DDE43FC DDE45FC
No comms DDF4F DDE408F DDE42F DDE43F DDE45F
With comms – DDE508FC DDE52FC DDE53FC DDE55FC
No comms DDF5F DDE508F DDE52F DDE53F DDE55F
With comms – DDJ408FC DDJ42FC DDJ43FC DDJ45FC
No comms DDK4F DDJ408F DDJ42F DDJ43F DDJ45F
With comms – DDJ508FC DDJ52FC DDJ53FC DDJ55FC
No comms DDK5F DDJ508F DDJ52F DDJ53F DDJ55F
With comms – DDM408L1FC DDM42L1FC DDM43L1FC DDM45L1FC
No comms DDN4L1F DDM408L1F DDM42L1F DDM43L1F DDM45L1F
With comms – DDM508L1FC DDM52L1FC DDM53L1FC DDM55L1FC
No comms DDN5L1F DDM508L1F DDM52L1F DDM53L1F DDM55L1F
With comms – DDM408L2FC DDM42L2FC DDM43L2FC DDM45L2FC
No comms DDN4L2F DDM408L2F DDM42L2F DDM43L2F DDM45L2F
With comms – DDM508L2FC DDM52L2FC DDM53L2FC DDM55L2FC
No comms DDN5L2F DDM508L2F DDM52L2F DDM53L2F DDM55L2F
With comms – DDM408L3FC DDM42L3FC DDM43L3FC DDM45L3FC
No comms DDN4L3F DDM408L3F DDM42L3F DDM43L3F DDM45L3F
With comms – DDM508L3FC DDM52L3FC DDM53L3FC DDM55L3FC
No comms DDN5L3F DDM508L3F DDM52L3F DDM53L3F DDM55L3F
With comms – – – – –
No comms DDP4SF – – – –
With comms – – – – –
No comms DDP5SF – – – –
With comms – – – – –
No comms – – – – –
With comms – – – – –
No comms – – – – –
13 A FUSED TAP-OFFS
Ele
ctr
ak
33
3 p
ha
se
sy
ste
m
27
– DDE408C DDE42C DDE43C DDE45C
DDF4 DDE408 DDE42 DDE43 DDE45
– DDE508C DDE52C DDE53C DDE55C
DDF5 DDE508 DDE52 DDE53 DDE55
– DDE408C DDE42C DDE43C DDE45C
DDF4 DDE408 DDE42 DDE43 DDE45
– DDE508C DDE52C DDE53C DDE55C
DDF5 DDE508 DDE52 DDE53 DDE55
– DDG408C DDG42C DDG43C DDG45C
DDH4 DDG408 DDG42 DDG43 DDG45
– DDG508C DDG52C DDG53C DDG55C
DDH5 DDG508 DDG52 DDG53 DDG55
– DDE408C DDE42C DDE43C DDE45C
DDF4 DDE408 DDE42 DDE43 DDE45
– DDE508C DDE52C DDE53C DDE55C
DDF5 DDE508 DDE52 DDE53 DDE55
– DDJ408C DDJ42C DDJ43C DDJ45C
DDK4 DDJ408 DDJ42 DDJ43 DDJ45
– DDJ508C DDJ52C DDJ53C DDJ55C
DDK5 DDJ508 DDJ52 DDJ53 DDJ55
– DDM408L1C DDM42L1C DDM43L1C DDM45L1C
DDN4L1 DDM408L1 DDM42L1 DDM43L1 DDM45L1
– DDM508L1C DDM52L1C DDM53L1C DDM55L1C
DDN5L1 DDM508L1 DDM52L1 DDM53L1 DDM55L1
– DDM408L2C DDM42L2C DDM43L2C DDM45L2C
DDN4L2 DDM408L2 DDM42L2 DDM43L2 DDM45L2
– DDM508L2C DDM52L2C DDM53L2C DDM55L2C
DDN5L2 DDM508L2 DDM52L2 DDM53L2 DDM55L2
– DDM408L3C DDM42L3C DDM43L3C DDM45L3C
DDN4L3 DDM408L3 DDM42L3 DDM43L3 DDM45L3
– DDM508L3C DDM52L3C DDM53L3C DDM55L3C
DDN5L3 DDM508L3 DDM52L3 DDM53L3 DDM55L3
– – – – –
DDP4S – – – –
– – – – –
DDP5S – – – –
– – – – –
– DDR408 DDR42 DDR43 DDR45
– – – – –
– DDR508 DDR52 DDR53 DDR55
Rewirable 0·8 m 2 m 3 m 5 m
16 A UNFUSED TAP-OFFS
28
Electrak® 30 2P + E Buscom trunkingpower and communication distribution
Pack Cat. Nos. Flexible lengths for single sided system
Flexible lengths can be used to change direction, change level or overcome obstructions
Suspended – right to left Length Rating Weight (m) (A) (kg)(1)
1 BBA140XC 0·5 25 2·91 1 BBA142XC 2 25 3·21 1 CCA140XC 0·5 40 2·94 1 CCA142XC 2 40 3·33
Surface mounted – right to left Length Rating Weight (m) (A) (kg)(1)
1 BBA340XC 0·5 25 2·99 1 BBA342XC 2 25 3·05 1 CCA340XC 0·5 40 3·02 1 CCA342XC 2 40 3·41
Pack Cat. Nos. Electrak 30 2 P + E + comms – single sided system
2P + E Buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on just one side of the bar
2P + E trunking lengths
Trunking lengths push fit into each other, and feed units or flexible lengths. Trunking lengths can be surface mounted or suspended using the various bracket options
Length Tap-off Weight 25 A (m) outlets (kg)(1)
1 BBA3145C 3 6 4·47 1 BBA2145C 2 4 3·27 1 BBA3141C 3 3 4·42 1 BBA2141C 2 2 3·24 40 A 1 CCA3145C 3 6 4·57 1 CCA2145C 2 4 3·36 1 CCA3141C 3 3 4·52 1 CCA2141C 2 2 3·31
Feed units for single sided system
Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop Centre feed units are supplied with right and left end stops
Suspended Weight (kg)(1)
1 BBA14LFC 25 A left 1·22 1 BBA14RFC 25 A right 1·49 1 CCA14LFC 40 A left 1·27 1 CCA14RFC 40 A right 1·49
Surface mounted Weight (kg)(1)
1 BBA34LFC 25 A left 1·31 1 BBA34RFC 25 A right 1·54 1 CCA34LFC 40 A left 1·31 1 CCA34RFC 40 A right 1·54
Centre feed Weight (kg)(1)
1 BBA44FC 25 A 1·8 1 CCA44FC 40 A 1·8
Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted
L
N
PE
C
Key : How to select the correct components All examples on this page show IP 4X Buscom trunking IP rating is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5
CCA14LFC
CCA14RFCCCA142XC
CCA3145C
CCA2145C
(1) Weights shown are for IP 4X rated Buscom. For all other
weights, contact us on +44 (0) 370 608 9020
Selection chart p. 24-27 Dimensions and technical information p. 38-43
29
Electrak® 30 2P + E Buscom trunkingpower and communication distribution
Pack Cat. Nos. Electrak 30 2 P + E + comms – double sided system
2P + E Buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on both sides of the bar The comms circuit is only available on one side of the bar as shown in the diagram below
2P + E trunking lengths
Trunking lengths push fit into each other, and feed units or flexible lengths. Double sided trunking must be fixed using suspended fixing brackets
Length Tap-off Weight 25 A (m) outlets (kg)(1)
1 BBA3245C 3 11 4·85 1 BBA2245C 2 7 3·52 1 BBA3241C 3 6 4·70 1 BBA2241C 2 4 3·47 40 A 1 CCA3245C 3 11 5·05 1 CCA2245C 2 7 3·65 1 CCA3241C 3 6 4·96 1 CCA2241C 2 4 3·61
Feed units for double sided system
Double sided feed units come with 2 x 25 mm Ø cable entry holes for each side of the bar, plus a further 2 x 16 mm Ø. holes for the comms side of the bar
Single screw cable terminals are provided for power and data. Supplied with end stops
Suspended Weight(kg)(1)
1 BBA24LFC 25 A left 1·29 1 BBA24RFC 25 A right 1·51 1 CCA24LFC 40 A left 1·39 1 CCA24RFC 40 A right 1·61
Flexible lengths for double sided system
Flexible lengths can be used to change direction, change level or overcome obstructions
Suspended – right to left Length Rating Weight (m) (A) (kg)(1)
1 BBA240XC 0·5 25 3·14 1 BBA242XC 2 25 3·67 1 CCA240XC 0·5 40 3·25 1 CCA242XC 2 40 3·91
Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted
LN
PE
PE
NL
C
Pack Cat. Nos. Tap-off units with and without comms
Power only tap-offs can plug into any tap-off outlet Tap-offs with comms can only be plugged into the comms side of the bar
16 A unfused tap-off units
Pre-wired tap-off units to pick-up L1+N, colour coded white
Length Fixed Weight (m) polarity (kg)(1)
1 DDE408C 0·8 0·2 1 DDE42C 2 0·4 1 DDE43C 3
L + N 0·5
1 DDE45C 5 0·7
13 A fused tap-off units
Pre-wired tap-off units to pick-up L1+N, supplied with BS 1362 fuse, colour coded white
Length Fixed Weight (m) polarity (kg)(1)
1 DDE408FC 0·8 0·2 1 DDE42FC 2 0·4 1 DDE43FC 3
L + N 0·5
1 DDE45FC 5 0·7
Tap-off units without comms – rewirable
16 A unfused tap-off unit
Rewirable tap-off unit to pick-up L1+N, colour coded white, can plug into any tap-off outlet
Fixed Weight polarity (kg)(1)
1 DDF4 L + N 0·14
13 A fused tap-off unit
Rewirable tap-off unit to pick-up L1+N, supplied with BS 1362 fuse, colour coded white, can plug into any tap-off outlet
Fixed Weight polarity (kg)(1)
1 DDF4F L + N 0·14
DDF4F
CCA3245C
CCA2245C
(1) Weights shown are for IP 4X rated Buscom. For all other
weights, contact us on +44 (0) 370 608 9020
Key : How to select the correct components All examples on this page show IP 4X Buscom trunking IP rating and tap-off type is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5C = Tap-off with communications circuit
For power only, remove the C
DDE45CDDE45
Selection chart p. 24-27 Dimensions and technical information p. 38-43
30
Electrak® 31 3P + E Buscom trunkingpower and communication distribution
Pack Cat. Nos. Flexible lengths for single sided system
Flexible lengths can be used to change direction, change level or overcome obstructions
Suspended – right to left
Length Rating Weight (m) (A) (kg)(1)
1 BBB140XC 0·5 25 3·04 1 BBB142XC 2 25 3·40 1 CCB140XC 0·5 40 3·08 1 CCB142XC 2 40 3·56
Surface mounted – right to left
Length Rating Weight (m) (A) (kg)(1)
1 BBB340XC 0·5 25 2·99 1 BBB342XC 2 25 3·32 1 CCB340XC 0·5 40 3·00 1 CCB342XC 2 40 3·48
Pack Cat. Nos. Electrak 31 3P + E – single sided system
3P + E Buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on just one side of the bar
3P + E trunking lengths
Trunking lengths push fit into each other, and feed units or flexible lengths. Trunking lengths can be surface mounted or suspended using the various bracket options
Length Tap-off Weight 25 A (m) outlets (kg)(1)
1 BBB3145C 3 6 4·62 1 BBB2145C 2 4 3·37 1 BBB3141C 3 3 4·58 1 BBB2141C 2 2 3·34 40 A 1 CCB3145C 3 6 4·77 1 CCB2145C 2 4 3·47 1 CCB3141C 3 3 4·73 1 CCB2141C 2 2 3·44
Feed units for single sided system
Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop Centre feed units are supplied with right and left end stops
Suspended Weight (kg)(1)
1 BBB14LFC 25 A left 1·25 1 BBB14RFC 25 A right 1·48 1 CCB14LFC 40 A left 1·33 1 CCB14RFC 40 A right 1·55
Surface mounted Weight (kg)(1)
1 BBB34LFC 25 A left 1·29 1 BBB34RFC 25 A right 1·52 1 CCB34LFC 40 A left 1·37 1 CCB34RFC 40 A right 1·59
Centre feed Weight (kg)(1)
1 BBB44FC 25 A 1·8 1 CCB44FC 40 A 1·8
Integral communication bus suitable for KNX, Lonworks, DALI, protocols etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted
L 2
L1
N
PE
C
CCB14LFC
CCB14RFCCCB142XC
CCB3145C
CCB2145C
(1) Weights shown are for IP 4X rated Buscom. For all other
weights, contact us on +44 (0) 370 608 9020
Key : How to select the correct components All examples on this page show IP 4X Buscom trunking IP rating is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5
Selection chart p. 24-27 Dimensions and technical information p. 38-43
31
Electrak® 31 3P + E Buscom trunkingpower and communication distribution
Pack Cat. Nos. Electrak 31 3P + E – double sided system
3P + E Buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on both sides of the bar The comms circuit is only available on one side of the bar as shown in the diagram below
3P + E trunking lengths
Trunking lengths push fit into each other, and feed units or flexible lengths. Double sided trunking must be fixed using suspended fixing brackets
Length Tap-off Weight 25 A (m) outlets (kg)(1)
1 BBB3245C 3 11 5·15 1 BBB2245C 2 7 3·72 1 BBB3241C 3 6 5·06 1 BBB2241C 2 4 3·68 40 A 1 CCB3245C 3 11 5·45 1 CCB2245C 2 7 3·92 1 CCB3241C 3 6 5·36 1 CCB2241C 2 4 3·88
Feed units for double sided system
Double sided feed units come with 2 x 25 mm Ø cable entry holes for each side of the bar, plus a further 2 x 16 mm Ø. holes for the comms side of the bar. Single screw cable terminals are provided for power and data
Suspended Weight (kg)(1)
1 BBB24LFC 25 A left 1·35 1 BBB24RFC 25 A right 1·58 1 CCB24LFC 40 A left 1·49 1 CCB24RFC 40 A right 1·72
Flexible lengths for double sided system
Flexible lengths can be used to change direction, change level or overcome obstructions
Suspended – right to left Length Rating Weight (m) (A) (kg)(1)
1 BBB240XC 0·5 25 3·45 1 BBB242XC 2 25 4·03 1 CCB240XC 0·5 40 3·53 1 CCB242XC 2 40 4·35
Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted
Pack Cat. Nos. Tap-off units with and without comms
Power only tap-offs can plug into any tap-off outlet Tap-offs with comms can only be plugged into the comms side of the bar
16 A unfused tap-off units
Pre-wired tap-off units to pick up L1, L2+N, colour coded white
Length Fixed Weight (m) polarity (kg)(1)
1 DDE408C 0·8 0·2 1 DDE42C 2 0·4 1 DDE43C 3
L + N 0·5
1 DDE45C 5 0·7
1 DDG408C 0·8 0·2 1 DDG42C 2 0·4 1 DDG43C 3
L1 + L2 + N 0·5
1 DDG45C 5 0·7
13 A fused tap-off units
Pre-wired tap-off units to pick-up L1, L2+N, supplied with BS 1362 fuse, colour coded white
Length Fixed Weight (m) polarity (kg)(1)
1 DDE408FC 0·8 0·2 1 DDE42FC 2 0·4 1 DDE43FC 3
L + N 0·5
1 DDE45FC 5 0·7
1 DDG408FC 0·8 0·2 1 DDG42FC 2 0·4 1 DDG43FC 3
L1 + L2 + N 0·5
1 DDG45FC 5 0·7
Tap-off units without comms – rewirable
16 A unfused tap-off unit
Rewirable tap-off units colour coded white, can plug into any tap-off outlet
Fixed Weight polarity (kg)(1)
1 DDF4 L + N 0·14 1 DDH4 L1 L2 N1 0·14
13 A fused tap-off unit
Rewirable tap-off units supplied with BS 1362 fuse, colour coded white, can plug into any tap-off outlet
Fixed Weight polarity (kg)(1)
1 DDF4F L + N 0·14 1 DDH4F L1 L2 N1 0·14
L2
L1
N
PE
PE
N
L1
L2
C
DDH4F
CCB3245C
CCB2245C
(1) Weights shown are for IP 4X rated Buscom. For all other
weights, contact us on +44 (0) 370 608 9020
Key : How to select the correct components All examples on this page show IP 4X Buscom trunking IP rating and tap-off type is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5C = Tap-off with communications circuit. For power only, remove the C
DDE45DDE45C
Selection chart p. 24-27 Dimensions and technical information p. 38-43
32
Electrak® 32 4P + E (dual circuit) Buscom trunkingpower and communication distribution
Pack Cat. Nos. Flexible lengths for single sided system
Flexible lengths can be used to change direction, change level or overcome obstructions
Suspended – right to left
Length Rating Weight (m) (A) (kg)(1)
1 BBC140XC 0·5 25 3·17 1 BBC142XC 2 25 3·59 1 CCC140XC 0·5 40 3·22 1 CCC142XC 2 40 3·79
Surface mounted – right to left
Length Rating Weight (m) (A) (kg)(1)
1 BBC340XC 0·5 25 3·09 1 BBC342XC 2 25 3·51 1 CCC340XC 0·5 40 3·14 1 CCC342XC 2 40 3·71
Pack Cat. Nos. Electrak 32 4P + E (dual circuit) – single sided system
Dual circuit Buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on just one side of the bar
4 P + E trunking lengths
Trunking lengths push fit into each other, and feed units or flexible lengths. Trunking lengths can be surface mounted or suspended using the various bracket options
Length Tap-off Weight 25 A (m) outlets (kg)(1)
1 BBC3145C 3 6 4·77 1 BBC2145C 2 4 3·47 1 BBC3141C 3 3 4·73 1 BBC2141C 2 2 3·44 40 A 1 CCC3145C 3 6 4·97 1 CCC2145C 2 4 3·61 1 CCC3141C 3 3 4·93 1 CCC2141C 2 2 3·58
Feed units for single sided system
Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop Centre feed units are supplied with right and left end stops
Suspended Weight (kg)(1)
1 BBC14LFC 25 A left 1·29 1 BBC14RFC 25 A right 1·52 1 CCC14LFC 40 A left 1·38 1 CCC14RFC 40 A right 1·61
Surface mounted Weight (kg)(1)
1 BBC34LFC 25 A left 1·33 1 BBC34RFC 25 A right 1·56 1 CCC34LFC 40 A left 1·42 1 CCC34RFC 40 A right 1·65
Centre feed Weight (kg)(1)
1 BBC44FC 25 A 1·8 1 CCC44FC 40 A 1·8
Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted
CL2
N2
L1
N1
PE
CCC14LFC
CCC14RFCCCC142XC
CCC3145C
CCC2145C
(1) Weights shown are for IP 4X rated Buscom. For all other
weights, contact us on +44 (0) 370 608 9020
Key : How to select the correct components All examples on this page show IP 4X Buscom trunking IP rating is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5
Selection chart p. 24-27 Dimensions and technical information p. 38-43
33
Electrak® 32 4P + E (dual circuit) Buscom trunkingpower and communication distribution
Pack Cat. Nos. Electrak 32 4P + E (dual circuit) – double sided system
Dual circuit Buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on both sides of the bar The comms circuit is only available on one side of the bar as shown in the diagram below
4 P + E trunking lengths
Trunking lengths push fit into each other, and feed units or flexible lengths. Double sided trunking must be fixed using suspended fixing brackets
Length Tap-off Weight 25 A (m) outlets (kg)(1)
1 BBC3245C 3 11 5·46 1 BBC2245C 2 7 3·92 1 BBC3241C 3 6 5·37 1 BBC2241C 2 4 3·88 40 A 1 CCC3245C 3 11 5·86 1 CCC2245C 2 7 4·70 1 CCC3241C 3 6 5·77 1 CCC2241C 2 4 4·15
Feed units for double sided system
Double sided feed units come with 2 x 25 mm Ø cable entry holes for each side of the bar, plus a further 2 x 16 mm Ø. holes for the comms side of the bar. Single screw cable terminals are provided for power and data Supplied with end stops
Suspended Weight (kg)(1)
1 BBC24LFC 25 A left 1·42 1 BBC24RFC 25 A right 1·64 1 CCC24LFC 40 A left 1·60 1 CCC24RFC 40 A right 1·83
Flexible lengths for double sided system
Flexible lengths can be used to change direction, change level or overcome obstructions
Suspended – right to left Length Rating Weight (m) (A) (kg)(1)
1 BBC240XC 0·5 25 3·42 1 BBC242XC 2 25 4·52 1 CCC240XC 0·5 40 3·91 1 CCC242XC 2 40 5·32
Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted
Pack Cat. Nos. Tap-off units with and without comms
Power only tap-offs can plug into any tap-off outlet Tap-offs with comms can only be plugged into the comms side of the bar
16 A unfused tap-off units
Pre-wired tap-off units to pick up L1+N1 or L2+N2, colour coded white
Length Fixed Weight (m) polarity (kg)(1)
1 DDE408C 0·8 0·2 1 DDE42C 2 0·4 1 DDE43C 3
L1 + N1 0·5
1 DDE45C 5 0·6
1 DDJ408C 0·8 0·2 1 DDJ42C 2 0·4 1 DDJ43C 3
L2 + N2 0·5
1 DDJ45C 5 0·6
13 A fused tap-off units
Pre-wired tap-off units to pick up L1+N1 or L2+N2, supplied with BS 1362 fuse, colour coded white
Length Fixed Weight (m) polarity (kg)(1)
1 DDE408FC 0·8 0·2 1 DDE42FC 2 0·4 1 DDE43FC 3
L1 + N1 0·5
1 DDE45FC 5 0·6
1 DDJ408FC 0·8 0·2 1 DDJ42FC 2 0·4 1 DDJ43FC 3
L2 + N2 0·5
1 DDJ45FC 5 0·6
Tap-off units without comms – rewirable
16 A unfused tap-off units
Rewirable tap-off units to pick up required circuit, colour coded white, can plug into any tap-off outlet
Fixed Weight polarity (kg)(1)
1 DDF4 L1 + N1 0·14 1 DDK4 L2 + N2 0·14
13 A fused tap-off units
Rewirable tap-off units to pick up required circuit, supplied with BS 1362 fuse, colour coded white, can plug into any tap-off outlet
Fixed Weight polarity (kg)(1)
1 DDF4F L1 + N1 0·14 1 DDK4F L2 + N2 0·14
CL2
N2
L1
N1
PE
N1
L1
N2
L2
PE
DDK4F
CCC3245C
CCC2245C
(1) Weights shown are for IP 4X rated Buscom. For all other
weights, contact us on +44 (0) 370 608 9020
Key : How to select the correct components All examples on this page show IP 4X Buscom trunking IP rating and tap-off type is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5C = Tap-off with communications circuit. For power only, remove the C
DDJ45CDDJ45
Selection chart p. 24-27 Dimensions and technical information p. 38-43
34
Electrak® 33 4P + E (3 phase) Buscom trunkingpower and communication distribution
Pack Cat. Nos. Flexible lengths for single sided system
Flexible lengths can be used to change direction, change level or overcome obstructions
Suspended – right to left
Length Rating Weight (m) (A) (kg)(1)
1 BBD140XC 0·5 25 3·17 1 BBD142XC 2 25 3·59 1 CCD140XC 0·5 40 3·22 1 CCD142XC 2 40 3·79
Surface mounted – right to left
Length Rating Weight (m) (A) (kg)(1)
1 BBD340XC 0·5 25 3·09 1 BBD342XC 2 25 3·51 1 CCD340XC 0·5 40 3·14 1 CCD342XC 2 40 3·71
Pack Cat. Nos. Electrak 33 4P + E (3 phase) – single sided system
3 phase Buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded grey and are located on just one side of the bar
4 P + E trunking lengths
Trunking lengths push fit into each other, and feed units or flexible lengths. Trunking lengths can be surface mounted or suspended using the various bracket options
Length Tap-off Weight 25 A (m) outlets (kg)(1)
1 BBD3145C 3 6 4·77 1 BBD2145C 2 4 3·47 1 BBD3141C 3 3 4·75 1 BBD2141C 2 2 3·44 40 A 1 CCD3145C 3 6 4·97 1 CCD2145C 2 4 3·61 1 CCD3141C 3 3 4·93 1 CCD2141C 2 2 3·58
Feed units for single sided system
Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop Centre feed units are supplied with right and left end stops
Suspended Weight (kg)(1)
1 BBD14LFC 25 A left 1·29 1 BBD14RFC 25 A right 1·52 1 CCD14LFC 40 A left 1·38 1 CCD14RFC 40 A right 1·61
Surface mounted Weight (kg)(1)
1 BBD34LFC 25 A left 1·33 1 BBD34RFC 25 A right 1·56 1 CCD34LFC 40 A left 1·42 1 CCD34RFC 40 A right 1·65
Centre feed Weight (kg)(1)
1 BBD44FC 25 A 1·80 1 CCD44FC 40 A 1·80
Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted
L3
L2
L1
N1
PE
C
CCD14LFC
CCD14RFCCCD142XC
CCD3145C
CCD2145C
(1) Weights shown are for IP 4X rated Buscom. For all other
weights, contact us on +44 (0) 370 608 9020
Key : How to select the correct components All examples on this page show IP 4X Buscom trunking IP rating is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5
Selection chart p. 24-27 Dimensions and technical information p. 38-43
35
Electrak® 33 4P + E (3 phase) Buscom trunkingpower and communication distribution
Pack Cat. Nos. Electrak 33 4P + E (3 phase) – double sided system
3 phase Buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded grey and are located on both sides of the bar The comms circuit is only available on one side of the bar as shown in the diagram below
4 P + E trunking lengths
Trunking lengths push fit into each other, and feed units or flexible lengths. Double sided trunking must be fixed using suspended fixing brackets
Length Tap-off Weight 25 A (m) outlets (kg)(1)
1 BBD3245C 3 11 5·46 1 BBD2245C 2 7 3·92 1 BBD3241C 3 6 5·37 1 BBD2241C 2 4 3·88 40 A 1 CCD3245C 3 11 5·86 1 CCD2245C 2 7 4·70 1 CCD3241C 3 6 5·77 1 CCD2241C 2 4 4·15
Feed units for double sided system
Double sided feed units come with 2 x 25 mm Ø cable entry holes for each side of the bar, plus a further 2 x 16 mm Ø. holes for the comms side of the bar. Single screw cable terminals are provided for power and data
Suspended Weight (kg)(1)
1 BBD24LFC 25 A left 1·42 1 BBD24RFC 25 A right 1·64 1 CCD24LFC 40 A left 1·60 1 CCD24RFC 40 A right 1·83
Flexible lengths for double sided system
Flexible lengths can be used to change direction, change level or overcome obstructions
Suspended – right to left
Length Rating Weight (m) (A) (kg)(1)
1 BBD240XC 0·5 25 3·42 1 BBD242XC 2 25 4·52 1 CCD240XC 0·5 40 3·91 1 CCD242XC 2 40 5·32
Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted
Pack Cat. Nos. Tap-off units
Power only tap-offs can plug into any tap-off outlet of the 3 phase bar Tap-offs with comms can only be plugged into the comms side of the 3 phase bar
16 A unfused tap-off units
Pre-wired tap-off units to pick up required circuit, colour coded grey
Length Fixed Weight (m) polarity (kg)(1)
1 DDM408L1C 0·8 0·2 1 DDM42L1C 2 0·4 1 DDM43L1C 3
L1 + N 0·5
1 DDM45L1C 5 0·6
1 DDM408L2C 0·8 0·2 1 DDM42L2C 2 0·4 1 DDM43L2C 3
L2 + N 0·5
1 DDM45L2C 5 0·6
1 DDM408L3C 0·8 0·2 1 DDM42L3C 2 0·4 1 DDM43L3C 3
L3 + N
0·5 1 DDM45L3C 5 0·6
13 A fused tap-off units
Pre-wired tap-off units to pick up required circuit, supplied with BS 1362 fuse, colour coded grey, can plug into any Electrak 33 tap-off outlet
Length Fixed Weight (m) polarity (kg)(1)
1 DDM408L1FC 0·8 0·2 1 DDM42L1FC 2 0·4 1 DDM43L1FC 3
L1 + N 0·5
1 DDM45L1FC 5 0·6
1 DDM408L2FC 0·8 0·2 1 DDM42L2FC 2 0·4 1 DDM43L2FC 3
L2 + N 0·5
1 DDM45L2FC 5 0·6
1 DDM408L3FC 0·8 0·2 1 DDM42L3FC 2 0·4 1 DDM43L3FC 3
L3 + N 0·5
1 DDM45L3FC 5 0·6
N
L1
L2
L3
L3
L2
L1
N
PE
PE
C
DDM408L1C DDM408L1
CCD3245C
CCD2245C
(1) Weights shown are for IP 4X rated Buscom. For all other
weights, contact us on +44 (0) 370 608 9020
Key : How to select the correct components All examples on this page show IP 4X Buscom trunking IP rating and tap-off type is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5C = Tap-off with communications circuit. For power only, remove the C
Selection chart p. 24-27 Dimensions and technical information p. 38-43
36
Electrak® 33 4P + E (3 phase) Buscom trunkingpower and communication distribution
Pack Cat. Nos. Tap-off units without comms – rewirable
16 A unfused tap-off units
Rewirable tap-off units to pick up required circuit, colour coded grey, can plug into any Electrak 33 tap-off outlet
Fixed Weight polarity (kg)(1)
1 DDN4L1 L1 + N 0·14 1 DDN4L2 L2 + N 0·14 1 DDN4L3 L3 + N 0·14
13 A fused tap-off units
Rewirable tap-off units to pick up required circuit, supplied with BS 1362 fuse, colour coded grey, can plug into any Electrak 33 tap-off outlet
Fixed Weight polarity (kg)(1)
1 DDN4L1F L1 + N 0·14 1 DDN4L2F L2 + N 0·14 1 DDN4L3F L3 + N 0·14
Phase selectable tap-off units without comms 2P + E terminals – rewirable
16 A unfused tap-off unit
Rewirable tap-off units, phase selectable, colour coded grey, can plug into any Electrak 33 tap-off outlet
Fixed Weight polarity (kg)(1)
1 DDP4S L + N 0·14
13 A fused tap-off unit
Rewirable tap-off units, phase selectable, supplied with BS 1362 fuse, colour coded grey, can plug into any Electrak 33 tap-off outlet
Fixed Weight polarity (kg)(1)
1 DDP4SF L + N 0·14
Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted
Pack Cat. Nos. Tap-off units without comms – 4P + E pre-wired (LSOH 5 x 1·5 mm2 cable)
16 A unfused tap-off units
Pre-wired tap-off units to pick up required circuit, colour coded grey, can plug into any Electrak 33 tap-off outlet
Length Fixed Weight (m) polarity (kg)(1)
1 DDR408 0·8 L + L + L + N 0·20 1 DDR42 2 L + L + L + N 0·36 1 DDR43 3 L + L + L + N 0·50 1 DDR45 5 L + L + L + N 0·63
DDR43DDN4L1F
(1) Weights shown are for IP 4X rated Buscom. For all other
weights, contact us on +44 (0) 370 608 9020
Key : How to select the correct components All examples on this page show IP 4X Buscom trunking IP rating is dictated by the red letters
4 = IP 4X. For IP 54 version, replace 4 with 5
Selection chart p. 24-27 Dimensions and technical information p. 38-43
37
Electrak® Buscom trunkingfixings and ancillary items
Pack Cat. Nos. Fixings
1 EEA304 Trunking 57 mm edge surface mounting fixing bracket
1 EEA308 Trunking suspended fixing bracket
1 EEA312 Trunking suspended fixing bracket c/w cable duct stirrup. Used when running cable duct on top of buscom trunking
1 EEA324 Luminaire suspension fixing bracket
1 EEA328 Luminaire 45 mm edge suspension fixing bracket (clip on)
1 EEA332 Luminaire 57 mm edge suspension fixing bracket (clip on)
1 EEB340 Open hook luminaire suspended bracket
1 EEB344 Closed ring on luminaire
1 EEC348 Cable duct 3 m long x 50 mm(w) x 13 mm(h)
1 EEC357 Joint bracket cable duct
1 EEC352 Cable duct fixing bracket
Pack Cat. Nos. Ancillary items
1 EEC356 2 m empty length for adjusting the length at the end of a run (to be cut)
1 EEC360 IP 54 outlet cover (spare or replacement)
1 EEC364 Joint sleeve is used if load is hung off trunking joint or near when joint is centre of a fixing span
1 EEC366 Left hand end stop spare
1 EEC368 Right hand end stop spare
Brackets are manufactured from robust galvanised steel, ensuring that the entire installation can be expected to stand up to all normal site conditions
EEA304
EEA308
EEA324
EEA312
EEA328 EEA332
EEB340 EEB344
EEC356
EEC360EEC352 EEC364
Dimensions and technical information p. 41
38
Electrak® Buscom trunkingtechnical information
25 A rated - max. conductor size 6 mm2
40 A rated - max. conductor size 16 mm2
Double sided trunking feed units have power cable terminals on both sides.IP 4X galvanised steel IP 54 ABS
Comms BUSMax. conductor size 1·5 mm2
Red + Black -
2 pole + earth + comms
Feed units
Track lengths simply push fit together
Electrak Buscom trunking can be used with Electrak’s cost effective lighting control system, Lightrak KNX, or any other systems using control protocols such as KNX, Lonworks, DALI, etc.Electrak’s overhead trunking couples high quality engineering with rigidity of design, and provides power for a variety of applications including lighting, heating and ventilation. The robust easy fix modular system permits loads to be suspended directly from the trunking using Electrak’s various fixing brackets Push fit connection keeps installation costs to a minimum
Direct protection by enclosure. Indirect protection by protective circuit
Electrical test data
Derating factor for Electrak 32 single sided – 0·8 –
Derating factor for Electrak 32 double sided 0·8 0·7 –
Derating factor for Electrak 33 double sided – 0·8 –
Rated operational voltage (Ue) 230/400 230/400 V±Rated insulation voltage (Ui) 500 500 V±Frequency (f) 50/60 50/60 Hz
Rated impulse withstand voltage 4·0 4·0 KV
Busbar resistance (R20
) 3·9 2·7 m /m
Resistance (R1) 4·2 3·0 m /m
Impedance (Z1) 4·8 3·4 m /m
Reactance (X1) 2·5 1·6 m /m
Protective conductor 1·5 1·5 m /m
UOM 25 A 40 A
Volt drops
Live and neutral : busbars 9·0 6·0 mV/A/m
(R1+R2) Feed unit 3·0 2·4 mV/A
Tap-off 0·8 m 22·0 22·0 mV/A
Tap-off 2·0 m 52·0 52·0 mV/A
Flexible length assembly 0·5 m 5·0 3·5 mV/A
Flexible length assembly 2 m 20·0 14·0 mV/A
UOM 25 A 40 A
Earth fault loop
Impedance : busbar 4·5 3·0 m /m
Earth housing 1·5 1·5 m /m
Feed unit 2·4 2·4 m
Tap-off 0·8m 23·0 23·0 m
Tap-off 2·0m 53·0 53·0 m
Flexible length assembly 0·5 m 2·5 1·75 mV/A
Flexible length assembly 2 m 10·0 7·0 mV/A
Rated conditional short-circuit current (Icc) 16·0 16·0 KA
Rated short time withstand current (Icw) at 1 sec 0·65 1·0 KA
Rated peak short-circuit current (Ipk) 0·975 1·5 KA
Ambient temperature 35·0 35·0 ˚C
UOM 25 A 40 A
Mechanical data UOM
Number of conductors 2-10 2-10 –
Busbar conductor cross sectional area 4·0 6·0 mm2
Cable terminal capacity 6·0 16·0 mm2
Cable terminal capacity bus 1·5 1·5 mm2
Tap-off cable 16 A 1·5 1·5 mm2
Tap-off cable 13 A fused 1·5 1·5 mm2
Tap-off entry 16·0 16·0 mmØ
Feed unit entry holes power 25·0 25·0 mmØ
Feed unit entry holes bus 16·0 16·0 mmØ
IP rating (optional) 4 X (54) 4 X (54) –
25 A 40 A
Standards
ASTA approved to BS EN 60439-2 and IEC 439-2Manufactured within an approved ISO 9001 : 2015 facilityAssessed Quality Assurance Certificate No. 10679Electrak fully complies with the requirements of BS 7671 (IET Wiring Regulations)
Buscom trunking options
• L2 • L3
• L2 • N2 • L2
• L • L1 • L1 • L1
• N • N • N1 • N
PE PE PE PE
Communication bus
39
Electrak® Buscom trunkingtechnical data
Fixing distance (m) 1·5 2 2·5 3 3·5 4
Max. point load (deflection = 1/500 x span) (Kg) 20 17 13 12 9 7
Max. distributed load (deflection = 1/500 x span) (Kg) 33 28 22 20 15 12
Max. point load (deflection = 1/350 x span) (Kg) 33 24 18 16 10 9
Max. distributed load (deflection = 1/350 x span) (Kg) 55 40 30 26 16 15
Average ambient air temperature 25˚C 30˚C 35˚C 40˚C 45˚C 50˚C
Rating factor (K1) 1·1 1·05 1 0·95 0·90 0·85
Fixing distance in metres (m) 1·5 2 2·5 3 3·5 4
Max. point load (deflection = 1/500 x span) (Kg) 10 6 4·5 4 3·5 3
Max. distributed load (deflection = 1/500 x span) (Kg) 16 10 7·5 7 6 5
Max. point load (deflection = 1/350 x span) (Kg) 13 10 7 6 5 0
Max. distributed load (deflection = 1/350 x span) (Kg) 20 16 11 10 8 0
Communication control circuit
Type Bus cable (LSOH)
Construction Sheathed 0·5 mm2 copper twisted pair
Insulation - conductor Flame retardant low emission HCL
Sheath LSOH material
Rated insulation voltage (Ui) (between power circuit and bus) 500 V
Max. bus operating voltage 50 V
Max. bus operating current 0·65 A
Max. conductor resistance (@20˚C) 73·2 /km
Max. mutual capacitance 100 nf/km
Material specifications
Buscom trunking housing Galvanised steel
Busbars High conductivity copper
Busbar insulator Flame retardant LSOH to BS 7211
Trunking connector / tap-off entry box / cable connector Flame retardant polycarbonate
Tap-off housing Flame retardant polycarbonate
Trunking connector blades / tap-off blades Copper
Feed unit IP 4X Galvanised steel
Feed unit IP 54 ABS
Flexible length conduit Flame retardant LSOH nylon
Feed unit terminals / earth block Brass
Brackets Galvanised steel
13 A tap-off, fuse To BS 1362, ASTA approved
Durability
Electrak power and communications distribution systems are well designed and extremely robust. They can be expected to stand up to all normal site conditions. Electrak has been short circuit strength tested by ASTA
Earth fault loop impedance
BS 7671 IET Wiring Regulations require accurate determination of the total earth loop impedance, which must be sufficiently low to allow the protective device to operate within the specified time, which for socket outlets is 0·4 seconds The values relevant to Electrak for calculating the earth fault loop impedance are shown in the electrical test data table, see opposite
Buscom trunking rating in ambient temperatures
For ambient temperatures other than 35˚C apply the multiplier factor K1 to the rated current
Buscom trunking mechanical loading
For point loads and evenly distributed loads the maximum weight that can be supported is given below
Maximum loading for suspended buscom trunking
Maximum loading for surface mounted Buscom trunking
Notes
1. Where trunking joints occur in the middle of the suspension span, and weight is to be suspended from that point, it is recommened to use a strengthening bracket EEC364 over the joint to stop deflection
2. If the load requirements exceed the above figures, please contact us on +44 (0) 370 608 9020 For design information and technical specification, please contact us on +44 (0) 370 608 9020 Suspension rods and fixings should be of suitable size to carry the weight of both the track and suspended load
40
Electrak® Buscom trunkingdimensions
Fixing dimensions
220 195·5
195·5
500 500 500 500 500 304·5
3 000
195·5 1 000 1 000
220 500 500 500 304·5
2 000
195·5 1 000 804·5
804·5
32
45
57
209 308
517
220 209
429
57
220 32010
148
10452
52
148
220 308
828
300
57
0·5 m outlet spacings
0·5 m outlet spacings
0·5 m outlet spacings
0·5 m outlet spacings
2 x 25 Ø
2 x 25 Ø
4 x 25 Ø2 x 25 Ø
(
218
2 x 16 Ø
2 x 16 Ø
2 x 16 Ø 2 x 16 Ø
All dimensions (mm) are nominal
Buscom trunking 3 m
Buscom trunking 2 m
Feed unit – left
End stop – right
Centre feed – front view
End stop – left Surface feed unit – end view
Feed unit – right
End view both have 2 x 16 mm holes
extra in comms feed
Double sided system
Single sided system
Buscom trunking
End view
Suspended feed unit
41
Tap-off
fuse removal
Fuse holder
96
68
136
68
107
927·5 7·5
30
57
60
7Ø 7 Ø
7 Ø
15
82 21
38
16
3
14
1
12
8·5 Ø
8·5 Ø
38 21
82
99
·7
94
·5
12
8·5 Ø
8.5 Ø22
60 35
30 6 Ø 6 Ø
70
13
78 30
39 6 Ø 6 Ø
53
·5
8·5
77
50
95 59
3513
70
M5
70
M5
82 21
38
13
0
12
5
10
8
128·5 Ø
8·5 Ø
Cat. No. EEA304 Surface trunking fixing bracket
with trunking clipped in
Cat. No. EEA308 Suspended trunking
fixing bracket
Cat. No. EEA312 Suspended trunking
fixing bracket cable duct stirrup
Cat. No. EEC352 Cable duct fixing
bracket
Cat. No. EEA324 Luminaire
suspended fixing bracket
Cat. No. EEA328 Luminaire 45 mm
edge suspension fixing bracket
Cat. No. EEA332 Luminaire 57 mm
edge suspension fixing bracket
Pre-wired tap-offs – 33 mm deep
Fused tap-off
Rewirable and phase selection
tap-offs – 35 mm deep
Cat. No. EEB344
Closed ring hookCat. No. EEB340
Open hook
All dimensions (mm) are nominal
Electrak® Buscom trunkingdimensions (continued)
42
EEA312
EEB344EEC352 Cable duct bracket
Ensure surface is level. Screw fix through both fixing holes of surface fixing brackets to surface with No. 8 fixing screws Hook trunking into place and push fit to close
Suspended trunking fixing brackets
Calculate the distance between fixing brackets - the maximum fixing distance should not exceed 4 m. If loads are to be hung, please consult loading charts on page 39. The maximum Buscom trunking weight is 2 kg/m When fixing brackets to drop rods or surfaces, see mounting details below
EEA304 57 mm Edge surface fixing bracket
Surface mounted trunking fixing brackets
2
1
Considerations before installation
Considerations before installation
Cable duct clips into bracket
When using cable duct along trunking
Electrak’s Buscom trunking system comprises continuous lengths of galvanised steel trunking available in 2 m and 3 m lengths with integral connectors and regular tap-off outlets on one or both sides
Each trunking run commences with a feed unit for electrical and comms bus cable termination. The connection between the trunking, the feed unit and subsequent trunking lengths is push fit and requires no tools to terminate the connection or ensure good earthing. Each complete track run is finished with an end stop. Flexible lengths can be used to overcome obstructions or used as corners where required
The trunking system is available with IP 4X or IP 54 ingress protection, fully factory tested and ASTA approved to BS EN 60439-2
1
2
Buscom trunking lengths
2
21
21
End stop
Left feed unit
To install - push fit parts together
To take apart - use a screwdriver to depress the locking catch
12
Push fit connection
Push in to release
1
Design and installation
EEA308
Electrak® Buscom trunkinginstallation
43
EEA324 Luminaire fixing brackets
EEA328 45 mm Edge luminaire fixing brackets (maximum load 5 kg)
EEA332 57 mm Edge luminaire fixing bracket (maximum load 5 kg)See maximum loading charts p. 39
Luminaire mounting fixing brackets : surface trunking
Luminaire mounting fixing brackets : suspended trunking
EEB344
EEA304
EEA332
EEA304
EEA332
EEB340
All dimensions (mm) are nominal
Electrak® Buscom trunkinginstallation (continued)
0488 75 15 0488 77 - 0489 18 - 0489 20 - 0489 61 - 0489 71 -
0784 61 15 0784 93 - 0784 95 - 0784 96 -
0882 30 15 0883 09 -
5742 03 15
7300 92 15 7300 94 - 7301 91 - 7354 14 - 7354 16 - 7354 90 -
8330 92 15 8330 94 - 8331 91 -
BBA14LFC 28 BBA14RFC - BBA24LFC 29 BBA24RFC - BBA34LFC 28 BBA34RFC - BBA44FC - BBA140XC 22, 28 BBA142XC 28 BBA240XC 23, 29 BBA242XC 29 BBA340XC 28 BBA342XC - BBA2141C - BBA2145C - BBA2241C 29 BBA2245C - BBA3141C 28 BBA3145C - BBA3241C 29 BBA3245C -
BBB14LFC 30 BBB14RFC - BBB24LFC 31 BBB24RFC - BBB34LFC 30 BBB34RFC - BBB44FC - BBB140XC - BBB142XC - BBB240XC 31 BBB242XC - BBB340XC 30 BBB342XC - BBB2141C - BBB2145C - BBB2241C 31 BBB2245C - BBB3141C 30 BBB3145C - BBB3241C 31 BBB3245C -
BBC14LFC 32 BBC14RFC - BBC24LFC 33 BBC24RFC - BBC34LFC 32 BBC34RFC - BBC44FC - BBC140XC - BBC142XC - BBC240XC 33 BBC242XC - BBC340XC 32 BBC342XC - BBC2141C - BBC2145C - BBC2241C 33 BBC2245C - BBC3141C 32 BBC3145C - BBC3241C 33 BBC3245C -
BBD14LFC 34 BBD14RFC - BBD24LFC 35 BBD24RFC - BBD34LFC 34 BBD34RFC - BBD44FC - BBD140XC - BBD142XC -
BBD240XC 23, 35 BBD242XC - BBD340XC 34 BBD342XC - BBD2141C - BBD2145C - BBD2241C 35 BBD2245C - BBD3141C 34 BBD3145C - BBD3241C 35 BBD3245C -
BDA14LFC 22 BDA14RFC - BDA24LFC 23 BDA24RFC - BDA140XC 22 BDA142XC - BDA2145C - BDA2245C 23 BDA3145C 22 BDA3245C 23
BVITM6L503100W 14 BVITM6L505100W - BVITM6L508100W - BVITM6-5-LL-03 - BVITM6-5-LL-05 - BVITM6-5-LL-08 - BVITM6-L5T500 - BVITM6-LPW - BVITM6-LPW-F -
CCA14LFC 28 CCA14RFC - CCA24LFC 29 CCA24RFC - CCA34LFC 28 CCA34RFC - CCA44FC - CCA140XC 22, 28 CCA142XC 28 CCA240XC 23, 29 CCA242XC 29 CCA340XC 28 CCA342XC - CCA2141C - CCA2145C - CCA2241C 29 CCA2245C - CCA3141C 28 CCA3145C - CCA3241C 29
CCA3245C 29
CCB14LFC 30 CCB14RFC - CCB24LFC 31 CCB24RFC - CCB34LFC 30 CCB34RFC - CCB44FC - CCB140XC - CCB142XC - CCB240XC 31 CCB242XC - CCB340XC 30 CCB342XC - CCB2141C - CCB2145C - CCB2241C 31 CCB2245C - CCB3141C 30 CCB3145C - CCB3241C 31 CCB3245C -
CCC14LFC 32 CCC14RFC - CCC24LFC 33 CCC24RFC - CCC34LFC 32 CCC34RFC - CCC44FC - CCC140XC - CCC142XC - CCC240XC 33 CCC242XC - CCC340XC 32 CCC342XC - CCC2141C - CCC2145C - CCC2241C 33 CCC2245C - CCC3141C 32 CCC3145C - CCC3241C 33 CCC3245C -
CCD14LFC 34 CCD14RFC - CCD24LFC 35 CCD24RFC - CCD34LFC 34 CCD34RFC - CCD44FC - CCD140XC -
CCD142XC 34 CCD240XC 23, 35 CCD242XC - CCD340XC 34 CCD342XC - CCD2141C - CCD2145C - CCD2241C 35 CCD2245C - CCD3141C 34 CCD3145C - CCD3241C 35 CCD3245C -
CDA14LFC 22 CDA14RFC - CDA24LFC 23 CDA24RFC - CDA142XC 22 CDA142XC - CDA2145C - CDA2245C 23 CDA3145C 22 CDA3245C 23
DBB 15
DDD432 23 DDD435 - DDD435F - DDD435FG - DDD435G - DDD452 - DDD455 - DDD455F - DDD455FG - DDD455G - DDD482 - DDD485 - DDD485F - DDD485FG - DDD485G -
DDE42C 29, 31 33 DDE42FC - DDE43C - DDE43FC - DDE45C - DDE45FC - DDE408C - DDE408FC -
0480 00
0780 00
0880 00
5740 00
7300 00
8330 00
BBA
BBB
BBC
BBD
BDA
BVIT
CCA
CCB
CCC
CCD
CDA
DBB
DDD
DDE
44
Cat. Nos.
Page
No.
Cat. Nos.
Page
No.
Cat. Nos.
Page
No.
Cat. Nos.
Page
No.
Cat. Nos.
Page
No.
45
DDF4 29, 31 33 DDF4F -
DDG42C 31 DDG42FC - DDG43C - DDG43FC - DDG45C - DDG45FC - DDG408C - DDG408FC -
DDH4 31 DDH4F -
DDJ42C 33 DDJ42FC - DDJ43C - DDJ43FC - DDJ45C - DDJ45FC - DDJ408C - DDJ408FC -
DDK4 33 DDK4F -
DDM42L1C 35 DDM42L1FC - DDM42L2C - DDM42L2FC - DDM42L3C - DDM42L3FC - DDM43L1C - DDM43L1FC - DDM43L2C - DDM43L2FC - DDM43L3C - DDM43L3FC - DDM45L1C - DDM45L1FC - DDM45L2C - DDM45L2FC - DDM45L3C - DDM45L3FC - DDM408L1C - DDM408L1FC - DDM408L2C - DDM408L2FC -
DDM408L3C 35 DDM408L3FC -
DDN4L1 36 DDN4L1F - DDN4L2 - DDN4L2F - DDN4L3 - DDN4L3F -
DDP4S 36 DDP4SF -
DDR42 36 DDR43 - DDR45 - DDR408 -
EEA304 37 EEA308 - EEA312 - EEA324 - EEA328 - EEA332 -
EEB340 37 EEB344 -
EEC348 37 EEC352 - EEC356 - EEC357 - EEC360 - EEC364 - EEC366 - EEC368 -
FFA001 14 FFA004 - FFA006 - FFA014 - FFA020 - FFA021 - FFA022 - FFA024 - FFA025 - FFA026 -
FFC060 15 FFC061 15
FFD062 14 FFDBCU - FFDDDB - FFDDDB1 - FFDDDB2 -
FFG300 15 FFG305 - FFG350 14
HEADEND 14
MWS3A-DBB 15
UHS5 15 UHS7 15
DDF
DDG
DDH
DDJ
DDK
DDM
DDN
DDP
DDR
EEA
EEB
EEC
FFA
FFC
FFD
FFG
HEA
MWS
UHS
Cat. Nos.
Page
No.
Cat. Nos.
Page
No.
Cat. Nos.
Page
No.
Head office (UK and Ireland):Legrand Electric LimitedGreat King Street North, Birmingham, B19 2LFTel: +44 (0) 370 608 9000 Fax: +44 (0) 370 608 9004Website: www.legrand.co.uk
9995
43 L
ight
rak
light
ing
cont
rol g
uide
06/
2018
.5k
This document is printed on sustainably sourced paper. Please recycle.
The Legrand logo is a registered trademarkof the Legrand group of companies.
In accordance with its policy of continuous improvement, theCompany reserves the right to change specifications and designswithout notice. All illustrations, descriptions, dimensions and weightsin this catalogue are for guidance and cannot be held binding onthe Company. All contents and design presentation included in thispublication are © Legrand Electric Limited. All rights reserved. 2018
Contact details Quotations and Technical Support: Legrand Electric Ltd. Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 370 608 9020 Fax: +44 (0) 345 600 6760E-mail: [email protected]
Customer Services: Legrand Electric Ltd. No. 1 Industrial Estate Medmonsley Road, Consett County Durham, DH8 6SR Tel: +44 (0) 345 605 4333 Fax: +44 (0) 345 600 6366E-mail: [email protected]
Republic of Ireland: Tel: 01 295 9673 Fax: 01 295 4671E-mail: [email protected]
www.legrand.co.ukwww.legrand.ie
www.youtube.com/legrandtvuk
www.twitter.com/legranduk
www.voltimum.co.ukwww.voltimum.ie
FOLLOW US AT