15
Lighting Upgrade Manual November, 2014 Experience the Difference

Lighting Upgrade Manual

Embed Size (px)

Citation preview

Page 1: Lighting Upgrade Manual

LightingUpgrade Manual

November, 2014

Experience the Difference

Page 2: Lighting Upgrade Manual

Why You Should Consider Upgrading Your LightingYou can reduce your total cost of ownership significantly by upgrading your lighting to LED with LSI. From the parking lot throughout the site, LSI has a broad offering of high performance, energy efficient LED lighting solutions to fit your requirements. With an LED lighting solution, LSI can dramatically improve the appearance of your site efficiently and economically 24 hours a day – 7 days a week.

What a Lighting Upgrade Means to You

By bringing your current lighting to today’s new LED standards without adding additional fixtures you will enjoy –

Don’t forget – over a 10-year period, the capital cost of your lighting package will only be 10% of the total cost of ownership. The balance, 20% installation/maintenance and 70% energy are your greatest cost of ownership. By investing in an LED upgrade with LSI, this balance of 90% will be significantly reduced.

Greater marketing impact due to long-range visibility which draws customers to your site

Improved safety to customers and employees which means greater sales and reduced employee turnover

With the white LED light source not only is overall ‘seeability’ improved but LEDs work very well with security and surveillance video cameras to create an even greater sense of safety.

Increased vertical illumination making the overall site brighter and more inviting

Building Walls

Pump Faces

Column Cladding

Spanners

Improved lighting and seeability using less energy

Color consistence from all fixtures

Fascia

Entrance/Exit Areas

Parking Lot

© 2014 LSI Industries Inc.1

Page 3: Lighting Upgrade Manual

Remove Current Fixture

Remove Current Fixture

Remove Current Fixture

Scottsdale® (SC/SCF) - Encore® (EC) - Encore Top Access (ECTA) Upgrading to LegacyTM (CRU & CRUS) LED Canopy Solution

Scottsdale (SC)(Single deck only)

12” Deck Pan

12” Deck Pan

BOTTOMPAN

Encore Bottom Access (EC)(Single or Double Deck)

16” Deck Pan

16” Deck Pan

16” Deck Pan

Leaves 4” Round Hole

Leaves 4” Round Hole

Leaves 9” Round Hole

Leaves 9” Round Hole

Leaves 12” Round Hole

CRU or LED or CW UE CLR (specify color)

CRU

CRUS

CRUS SCDL

SC

AC

HO

VHO

CRUS or LED or CW UE CLR (specify color)

*Scottsdale Drop Lens available in LW and SS drive currrent.

SCAC

SCDL*

VLWLW

SS

Top Filler Plate w/Adhesive &Bottom Decorative Panel Kit

P/N 525946CLR(specify color)

ScottsdaleFlat Lens (SCF)

EncoreTop Access (ECTA)(Single deck only)

TOPPAN

BOTTOMPAN

TOPPAN

Top Filler Plate w/Adhesive &Bottom Decorative Panel Kit

P/N 530281CLR(specify color)

BOTTOMPAN

TOPPAN

Top Filler Plate w/Adhesive &Bottom Decorative Panel Kit

P/N 525946CLR(specify color)

© 2014 LSI Industries Inc.2

Page 4: Lighting Upgrade Manual

Remove Current Fixture

Remove Current Fixture

Remove Current Fixture

Scottsdale® (SC/SCF) - Encore® (EC) - Encore Top Access (ECTA) Upgrading to LegacyTM (CRU & CRUS) LED Canopy Solution

Scottsdale (SC)(Single deck only)

12” Deck Pan

12” Deck Pan

BOTTOMPAN

Encore Bottom Access (EC)(Single or Double Deck)

16” Deck Pan

16” Deck Pan

16” Deck Pan

Leaves 4” Round Hole

Leaves 4” Round Hole

Leaves 9” Round Hole

Leaves 9” Round Hole

Leaves 12” Round Hole

CRU or LED or CW UE CLR (specify color)

CRU

CRUS

SC

AC

HO

VHO

CRUS or LED or CW UE CLR (specify color)

*Scottsdale Drop Lens available in LW and SS drive currrent.

SCAC

SCDL*

VLWLW

SS

Top Filler Plate w/Adhesive &Bottom Decorative Panel Kit

P/N 525946CLR(specify color)

ScottsdaleFlat Lens (SCF)

EncoreTop Access (ECTA)(Single deck only)

TOPPAN

BOTTOMPAN

TOPPAN

Top Filler Plate w/Adhesive &Bottom Decorative Panel Kit

P/N 530281CLR(specify color)

BOTTOMPAN

TOPPAN

Top Filler Plate w/Adhesive &Bottom Decorative Panel Kit

P/N 525946CLR(specify color)

© 2014 LSI Industries Inc.3

Page 5: Lighting Upgrade Manual

Current Fixture

2 x 2 Surface Mount Upgrade to LegacyTM LED SuperKit (CRUK UNV OR CRUSK UNV)

Leave Existing Housing

Remove Existing Housing(Single Deck Only)

Blanking Panel Available

P/N 357282 - Kit DA/MA to Blank Panel

P/N 1320540 - Kit DA to SC Plugs (25 units)

Fixture

Retrofit Kit

P/N 357282 - Kit DA/MA to Blank Panel

P/N 1320540 - Kit DA to SC Plugs (25 units)

23 "

8"10"

19 3/8 "

LSI: Masters/Dakota®

Whiteway: Riviera

8"10"

21 1/8 "

19 3/8"

Whiteway: Riviera II, Thunderbird,Vision

Jet-Phillips: Houstonian (Current Style) SHO/RHO

Guardian MC-1411

Cooper CLS

23 "

8"11"

19 3/8 "

Jet-Phillips: Houstonian (Old Style)

23 "

8" 10"

19 3/8 "

21 1/8 "

8"10"

19 3/8 "

21 3/4 "

8 1/4"10 1/4"

19 3/8 "

LSI Masters/Dakota®

Side View

Side View

Side View

Side View

Side View

Whiteway Riviera

Jet-Phillips Houstonian (Old Style)

Jet-Phillips Houstonian

Cooper CLS

Guardian MC-1411

2x2 already installed with Scottsdale SSK SuperKit can be upgraded to Crossover LED CRUK UNV.

CRU

CRUK

CRUS

CRUSK

CRUS SCDL

CRUSK SCDL

CRUK UNV or LED or CW UE CLR (specify color)SC

AC

HO

VHO

CRUSK UNV or LED or CW UE CLR (specify color)

*Scottsdale Drop Lens available in LW and SS drive currrent.

SCAC

SCDL*

VLWLW

SS

CRU or LED or CW UE CLR (specify color)SC

AC

HO

VHO

CRUS or LED or CW UE CLR (specify color)

*Scottsdale Drop Lens available in LW and SS drive currrent.

SCAC

SCDL*

VLWLW

SS

© 2014 LSI Industries Inc.4

Page 6: Lighting Upgrade Manual

Current Fixture

2 x 2 Surface Mount Upgrade to LegacyTM LED SuperKit (CRUK UNV OR CRUSK UNV)

Leave Existing Housing

Remove Existing Housing(Single Deck Only)

Blanking Panel Available

P/N 357282 - Kit DA/MA to Blank Panel

P/N 1320540 - Kit DA to SC Plugs (25 units)

Fixture

Retrofit Kit

P/N 357282 - Kit DA/MA to Blank Panel

P/N 1320540 - Kit DA to SC Plugs (25 units)

23 "

8"10"

19 3/8 "

LSI: Masters/Dakota®

Whiteway: Riviera

8"10"

21 1/8 "

19 3/8"

Whiteway: Riviera II, Thunderbird,Vision

Jet-Phillips: Houstonian (Current Style) SHO/RHO

Guardian MC-1411

Cooper CLS

23 "

8"11"

19 3/8 "

Jet-Phillips: Houstonian (Old Style)

23 "

8" 10"

19 3/8 "

21 1/8 "

8"10"

19 3/8 "

21 3/4 "

8 1/4"10 1/4"

19 3/8 "

LSI Masters/Dakota®

Side View

Side View

Side View

Side View

Side View

Whiteway Riviera

Jet-Phillips Houstonian (Old Style)

Jet-Phillips Houstonian

Cooper CLS

Guardian MC-1411

2x2 already installed with Scottsdale SSK SuperKit can be upgraded to Crossover LED CRUK UNV.

CRU

CRUK

CRUS

CRUSK

CRUK UNV or LED or CW UE CLR (specify color)SC

AC

HO

VHO

CRUSK UNV or LED or CW UE CLR (specify color)

*Scottsdale Drop Lens available in LW and SS drive currrent.

SCAC

SCDL*

VLWLW

SS

CRU or LED or CW UE CLR (specify color)SC

AC

HO

VHO

CRUS or LED or CW UE CLR (specify color)

*Scottsdale Drop Lens available in LW and SS drive currrent.

SCAC

SCDL*

VLWLW

SS

© 2014 LSI Industries Inc.5

Page 7: Lighting Upgrade Manual

Current Fixture

Recessed Rectangular Upgrading to LegacyTM LED SuperKit (CRUK RECU OR CRUSK RECU)

Leave Existing Housing

Blanking Panel Available

1 - Rectangular recessed housings already installed with Scottsdale SSK SuperKit can be upgraded to Crossover LED CRUK RECU OR CRUSK RECU.

P/N 354702

8 9/16"

18 1/2"

LSI: Richmond®

Whiteway:Civic (current model)

Whiteway: Civic (old model)

Jet-Phillips: Recessed Icon (original model)

19 1/8"

9 3/8"

8 5/16"

17 1/2"

9"

18 1/16"

LSI Richmond ® Series

Whiteway: Civic(Current Model)

Jet-Phillips Recessed Icon(Original Model)

Whiteway: Civic(Old Style)

CRUK RECU

CRUSK RECU CRUSK RECU SCDL

CRUK RECU or LED or CW UE CLR (specify color)SC

AC

HO

VHO

CRUSK RECU or LED or CW UE CLR (specify color)

*Scottsdale Drop Lens available in LW and SS drive currrent.

SCAC

SCDL*

VLWLW

SS

© 2014 LSI Industries Inc.6

Page 8: Lighting Upgrade Manual

Current Fixture

Recessed Rectangular Upgrading to LegacyTM LED SuperKit (CRUK RECU OR CRUSK RECU)

Leave Existing Housing

Blanking Panel Available

1 - Rectangular recessed housings already installed with Scottsdale SSK SuperKit can be upgraded to Crossover LED CRUK RECU OR CRUSK RECU.

P/N 354702

8 9/16"

18 1/2"

LSI: Richmond®

Whiteway:Civic (current model)

Whiteway: Civic (old model)

Jet-Phillips: Recessed Icon (original model)

19 1/8"

9 3/8"

8 5/16"

17 1/2"

9"

18 1/16"

LSI Richmond ® Series

Whiteway: Civic(Current Model)

Jet-Phillips Recessed Icon(Original Model)

Whiteway: Civic(Old Style)

CRUK RECU CRUSK RECU

CRUK RECU or LED or CW UE CLR (specify color)SC

AC

HO

VHO

CRUSK RECU or LED or CW UE CLR (specify color)

*Scottsdale Drop Lens available in LW and SS drive currrent.

SCAC

SCDL*

VLWLW

SS

© 2014 LSI Industries Inc.7

Page 9: Lighting Upgrade Manual

Identify Current Fixture Choose New Fixture Identify Existing Pole Required Mounting (in addition to fixture)

250 watt through 400 watt HID fixtures

750 watt through 1000 watt HID fixtures

3” DrillingPattern

5” DrillingPattern

Existing Square Pole

Existing Round Pole

Existing Tenon Mount Pole

4” square order X4ISF5” square order X5ISF

Specify Configurationie: S, D90, D180, T90, or Q90

Specify Configurationie: S, D90, D180, T90, or Q90

Specify Configurationie: S, D90, D180, T90, or Q90

Specify Configurationie: S, D90, D180, T90, or Q90

Specify Configurationie: S, D90, D180, T90, or Q90

4” round order X4RPP5” round order X5RPP

Order XNM

2-1/8”(54mm)

Existing Square Pole

Existing Round Pole

Existing Tenon Mount Pole

4” square order 4ISF5” square order 5ISF

4” round order 4RPP5” round order 5RPP

Order NM

4-5/8”(117mm)

5” DrillingPattern

4-5/8”(117mm)

CH2HM/CH2VM

CTM/CT2H/CT2V

GFM/GBM1

HE

CHH/CHV

GBL/GFL/GBR/GFR2

Specify Configurationie: S, D90, D180, T90, or Q90Order NM

XCHM3

XGBM HO2

XLCS/XLCM

Existing Square Pole

Existing Round Pole

Existing Tenon Mount Pole

4” square order 4ISF5” square order 5ISF

4” round order 4RPP5” round order 5RPP

2 - If existing HID GFR/GFL/GBR/GBL, then upgrade to LED version XGBM HO by ordering new LED fixture only – same mounting hardware & drilling pattern applies, no additional hardware needed.

3 - RPP not needed for XSB

XGBM LW/SS1

Upgrade HID Area Lights to LED

RPP not needed for XSB

1 - If existing GFM/GBM, then upgrade to LED version XGBM LW/SS by ordering new LED fixture only – same mounting hardware & drilling pattern applies, no additional hardware needed.

XAMU

© 2014 LSI Industries Inc.8

Page 10: Lighting Upgrade Manual

Identify Current Fixture Choose New Fixture Identify Existing Pole Required Mounting (in addition to fixture)

250 watt through 400 watt HID fixtures

750 watt through 1000 watt HID fixtures

3” DrillingPattern

5” DrillingPattern

Existing Square Pole

Existing Round Pole

Existing Tenon Mount Pole

4” square order X4ISF5” square order X5ISF

Specify Configurationie: S, D90, D180, T90, or Q90

Specify Configurationie: S, D90, D180, T90, or Q90

Specify Configurationie: S, D90, D180, T90, or Q90

Specify Configurationie: S, D90, D180, T90, or Q90

Specify Configurationie: S, D90, D180, T90, or Q90

4” round order X4RPP5” round order X5RPP

Order XNM

2-1/8”(54mm)

Existing Square Pole

Existing Round Pole

Existing Tenon Mount Pole

4” square order 4ISF5” square order 5ISF

4” round order 4RPP5” round order 5RPP

Order NM

4-5/8”(117mm)

5” DrillingPattern

4-5/8”(117mm)

CH2HM/CH2VM

CTM/CT2H/CT2V

GFM/GBM1

HE

CHH/CHV

GBL/GFL/GBR/GFR2

Specify Configurationie: S, D90, D180, T90, or Q90Order NM

XCHM3 XPT3 XPTS3

XGBM HO2 XSB3

XASU PASUXLCS/XLCM

Existing Square Pole

Existing Round Pole

Existing Tenon Mount Pole

4” square order 4ISF5” square order 5ISF

4” round order 4RPP5” round order 5RPP

2 - If existing HID GFR/GFL/GBR/GBL, then upgrade to LED version XGBM HO by ordering new LED fixture only – same mounting hardware & drilling pattern applies, no additional hardware needed.

3 - RPP not needed for XSB

XGBM LW/SS1

Upgrade HID Area Lights to LED

RPP not needed for XSB

1 - If existing GFM/GBM, then upgrade to LED version XGBM LW/SS by ordering new LED fixture only – same mounting hardware & drilling pattern applies, no additional hardware needed.

XAMU

© 2014 LSI Industries Inc.9

Page 11: Lighting Upgrade Manual

LSI LED bollards deliver good uniform illumination to light walkways and sidewalks.

The LED XIG inground fixture is designed to light flags or signage.

LSI offers several LED solutions for soffit applications – from continuous row building soffit strips to a moretraditional soffit fixture design. Depending upon yoursoffit ceiling structure and lighting requirements, you canget outstanding illumination while using considerably lessenergy than a standard HID fixture.

The Legacy Surface Mount is designed for applications where mounting and servicing requirements necessitate surface mount and access from below. It features the same performance, energy saving and installation benefits as the Legacy canopy solution.

Choose from a number of LED wall pack fixtures that deliver uniform lighting with full cutoff to create a brighter environment at lower light levels. Optional motion sensors are available for additional energy savings as well as emergence options that meet NFPA Life Safety Code requirements. These fixtures are ideal for entrance, egress and security lighting requirements.

The LWW is designed for seamless continuous row mounting on an interior or exterior wall. High Lux LEDs produce approximately 260 lumens at 3.5 watts per foot. The LED wall wash is a highly dramatic and efficient means of wall illumination.

The LWF is an efficient and easy system for constructing continuous row building face lighting from above the top of a fascia. Brilliant High Lux LEDs produce about 260 lumens at 3.5 watts per foot.

Transitional Walkway

Soffit

Surface Mount

Wall Pack

LED Linear Wall Wash / Fascia

LSI Petroleum Lighting offers a number of LED solutions to upgrade the rest of the exterior of your site.

© 2014 LSI Industries Inc.10

Page 12: Lighting Upgrade Manual

Site # Date:

Site Address

City, St, Zip

Surveyors Name

Check each item as completed. Photos show overall context and entire site

)tnemecalp elop erutpac( sotohP etiS llarevO otohP sserddA etiS

Canopy Dimensions

Quantity of 2' x 2' Boxes Quantity of Richmonds

Quantity of 2' x 2' Upgrade Quantity of Flat Lens Scottsdale, Encore, BTM Access, Top Access

Quantity of Scottsdale

* Note damage or non-working fixtures:

Quantity of Standard Wall Packs Quantity of Decorative or Gooseneck

Quantity of Jar Light w/ INC Quantity of other Fixture

Wall Pack photographed Damage Photographed as needed in context of entire wall

Wall Mounted: Pole Mounted:Quantity Single Head Quantity Single Head

Quantity Double Head Quantity Double Head

Roof Mounted: Sign Mounted:Quantity Single Head Quantity Single Head

Quantity Double Head Quantity Double Head

Flood Light Fixtures photographed in context of entire wall Damage Photographed as needed

LED Retrofit Survey Form

General Site Information

Canopy information

Wall Pack Lighting Fixtures

Flood Light Fixtures

LED Retrofit Survey Form

Site #

Site Address:

Aluminum Steel Concrete Mounting Method: Bolted Welded

Qty Round Qty Singles

Qty Round Tappered Qty Doubles (D-90,DN-90,D-180)

Qty 4" SQ Qty Triple (T-90, TN-90)

Qty 5" SQ Qty Quad

Qty 6" SQ Fixture type:

dnuorgotthgilehtmorferusaem-thgieHeloP:egattaW

Color:

Note damage, rust and obstructions for Area Light poles:

Survey Form Reviewed for Site Photos Reviewed for 100% noitelpmoCycaruccA

Note any other site comments that are not captured elsewhere on this form:

Survey Finalization

Pole Information

liateDeloPdaeHeloPthgiLaerA

© 2014 LSI Industries Inc.11

Page 13: Lighting Upgrade Manual

Site # Date:

Site Address

City, St, Zip

Surveyors Name

Check each item as completed. Photos show overall context and entire site

)tnemecalpeloperutpac(sotohPetiSllarevOotohPsserddAetiS

Canopy Dimensions

Quantity of 2' x 2' Boxes Quantity of Richmonds

Quantity of 2' x 2' Upgrade Quantity of Flat Lens Scottsdale, Encore, BTM Access, Top Access

Quantity of Scottsdale

* Note damage or non-working fixtures:

Quantity of Standard Wall Packs Quantity of Decorative or Gooseneck

Quantity of Jar Light w/ INC Quantity of other Fixture

Wall Pack photographed Damage Photographed as needed in context of entire wall

Wall Mounted: Pole Mounted:Quantity Single Head Quantity Single Head

Quantity Double Head Quantity Double Head

Roof Mounted: Sign Mounted:Quantity Single Head Quantity Single Head

Quantity Double Head Quantity Double Head

Flood Light Fixtures photographed in context of entire wall Damage Photographed as needed

LED Retrofit Survey Form

General Site Information

Canopy information

Wall Pack Lighting Fixtures

Flood Light Fixtures

LED Retrofit Survey Form

Site #

Site Address:

Aluminum Steel Concrete Mounting Method: Bolted Welded

Qty Round Qty Singles

Qty Round Tappered Qty Doubles (D-90,DN-90,D-180)

Qty 4" SQ Qty Triple (T-90, TN-90)

Qty 5" SQ Qty Quad

Qty 6" SQ Fixture type:

dnuorg ot thgil eht morf erusaem -thgieH eloP:egattaW

Color:

Note damage, rust and obstructions for Area Light poles:

Survey Form Reviewed for Site Photos Reviewed for 100% noitelpmoC ycaruccA

Note any other site comments that are not captured elsewhere on this form:

Survey Finalization

Pole Information

liateD eloP daeH eloP thgiL aerA

© 2014 LSI Industries Inc.12

Page 14: Lighting Upgrade Manual

Site #

Site Address:

Include all fixtures, light poles, canopy dimensions and curbs in drawing. Use a straight edge where possible and write legibly

All site plans must include dimensions of canopy, all lights identified on survey form, curbs showing entrance/exit and general parking lot layout. Submit site plan as a separate file from survey pack.

Site Plan Sketch

LED Retrofit Survey Form

© 2014 LSI Industries Inc.13

Page 15: Lighting Upgrade Manual

4504 11/14 2500 © 2014 LSI Industries Inc.

10000 Alliance Road � Cincinnati, Ohio 45242 � (513)793-3200 Fax: (866)316-7126 � www.lsi-industries.com