18
LIGHTING CONSTRUCTION MANUAL COLUMNS MINOR ROAD Go to SECTION INDEX Back to MAIN INDEX

LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

Embed Size (px)

Citation preview

Page 1: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

LIGHTING CONSTRUCTION MANUAL

COLUMNS MINOR ROAD

Go to SECTION INDEX Back to MAIN INDEX

Page 2: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

1-6-1-1

1 6 1-1 0E

LIGHTING

10500-A4-1-6-1-1

1-6-2-1

DESCRIPTIONTYPE PAGE TYPE DESCRIPTION PAGE

B 10.12.12

1-6-2-2

NOSTALGIA POLE / FOUNDATION CONSTRUCTION

1-6-4-2

1-6-4-1

1-6-3-2

1-6-3-1SLNOS

SLBPM

SL

SL Single & Double Outreach - Materials

Single & Double Outreach - Construction

COLUMNS MINOR ROAD INDEX

Construction Type Guide - Estate Pole

1-6-5-2

1-6-5-1

1-6-6-2

1-6-6-1Mid Hinged BPM / Foundation - U/G Service

Mid Hinged BPM / Foundation - U/G Service

1-6-7-2

1-6-7-1Mid Hinged BPM / Foundation - U/G Service

Mid Hinged BPM / Foundation - U/G Service

SLNOSD

SL

BPM Steel Pole / Foundation Nostalgia

BPM Steel Pole / Foundation Nostalgia

BPM Steel Pole / Foundation Nostalgia

BPM Steel Pole / Foundation Nostalgia

BPM Steel Pole / Foundation

BPM Steel Pole / Foundation

Type 1 & 2 - Materials

Type 1 & 2 - Construction

Double Outreach - Materials

Double Outreach - Construction

6.5m Pole 0.5m Single Outreach - Construction

6.5m Pole 0.5m Single Outreach - Materials

0.5m Single Outreach - Construction

0.5m Single Outreach - Materials

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

01/11/10

1-6-2-4

1-6-2-5

Construction Type Guide - Estate Pole

Construction Type Guide - BPM Pole

Foundation & Luminaire - Energex

Foundation & Luminaire - Energex

Foundation & Luminaire - Ergon

18.12.13C

23.03.16D

06.03.17E

1-6-2-3Construction Type Guide - Luminaire - Ergon

Construction Type Guide - BPM Pole Foundation - Ergon

1-6-2-6Construction Type Guide - LED Luminaire - Energex

Page 3: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

SL N 1 CF32

SL NOS 1 PC

( )

STREETLIGHT

SL = Streetlight

EXAMPLE:-

EXAMPLE:-

POLE

NOS = Nostalgia

FOUNDATION TYPE

PC = Precast

CI = Cast in situ

is constructed by others

Omit where foundation

STREETLIGHT

SL = Streetlight

LUMINAIRE

N = Nostalgia

POLE TOP TYPE

1 = Type 1 (Green)

2 = Type 2 (Blue/Grey)

LAMP TYPE AND WATTAGE

EXAMPLE:-

A

A

ESTATE STREETLIGHT POLE / FOUNDATION CONSTRUCTION TYPE

detail drawings in this manual.

appears on relevant construction

Type shown within dashed box

detail drawings in this manual.

appears on relevant construction

Type shown within dashed box

ESTATE STREETLIGHT LUMINAIRE CONSTRUCTION TYPE

B 14.01.13

SLN1CF32 = Streetlight, nostalgia luminaire type 1, compact fluorescent 32 watt lamp.

3 = Type 1 (Black)

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

14/10/10

C 18.12.13

POLE COLOUR

1 = Green

2 = Blue/Grey

3 = Black

SLNOS1PC = Streetlight, nostalgia green pole including precast foundation.

SLNOS2 = Streetlight, nostalgia blue/grey pole, no foundation.

1-6-2-1

1 6 2-1 0E

LIGHTINGCOLUMNS MINOR ROAD - ERGON ENERGY ONLY

CONSTRUCTION TYPE GUIDE

ESTATE POLE / FOUNDATION & LUMINAIRE

10500-A4-1-6-2-1

5 85 8040 1

NIL

D 31.07.14

E 23.03.17

CF32 = Compact Fluorescent 32W LampS70D = HPS 70W Diffused Lamp

Page 4: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

( )

STREETLIGHT

SL = Streetlight

POLE TYPE

(Steel)

BPM = Base Plate Mounted

MOUNTING HEIGHT

75 = 7.5m

No. OF OUTREACH

1 = Single

2 = Double

OUTREACH DIMENSION

15 = 1.5m

FOUNDATION TYPE

PC = Precast

CI = Cast in situ

is constructed by others

Omit where foundation

EXAMPLE:-

EXAMPLE:-

A

STREETLIGHT POLE / FOUNDATION CONSTRUCTION TYPE

detail drawings in this manual.

appears on relevant construction

Type shown within dashed box

SL BPM75/1/15 PC

SLBPM75/1/15PC = Streetlight, base plate mounted pole, 7.5m mounting height, single 1.5m outreach including precast foundation.

SLBPM75/2/15 = Streetlight, base plate mounted pole, 7.5m mounting height, double 1.5m outreach, no foundation.

B 14.01.13

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

14/10/10

C 23.10.14

D 10.06.15

E 22.11.16

1-6-2-2

1 6 2-2 0E

LIGHTINGCOLUMNS MINOR ROAD - ERGON ENERGY ONLY

CONSTRUCTION TYPE GUIDE

BPM POLE / FOUNDATION

10500-A4-1-6-2-2

5 85 8040 2

NIL

Page 5: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

EXAMPLE:-

EXAMPLE:-

STREETLIGHT

SL = Streetlight

LAMP TYPE AND WATTAGE

A

STREETLIGHT LUMINAIRE MINOR ROAD CONSTRUCTION TYPE

detail drawings in this manual.

appears on relevant construction

Type shown within dashed box

SL HPS 0001

HPS = High Pressure Sodium Vapour

LF = Linear Fluorescent

CFL = Compact Fluorescent

MH = Metal Halide

PRODUCT CODE

SL HPS 0001 = Streetlight, High pressure sodium vapour, 70W

SL MH 0005 = Streetlight, metal halide, 35W

0001 = Sylvania Suburban 70W HPS

0003 = Sylvania Suburban 32W CFL

0005 = Sylvania Suburban 35W MH

0007 = Sylvania Suburban 70W MH

0002 = Sylvania Urban Aeroscreen 70W HPS

0004 = Sylvania Urban Aeroscreen 32W CFL

0006 = Sylvania Urban Aeroscreen 35W MH

0008 = Sylvania Urban Aeroscreen 70W MH

0032 = Greenstreet T5 2 x 24W

1-6-2-3

1 6 2-3 0A

LIGHTINGCOLUMNS MINOR ROAD - ERGON ENERGY ONLY

CONSTRUCTION TYPE GUIDE

LUMINAIRE

10500-A4-1-6-2-3

5 85 8040 2

NIL

EXAMPLE:-

EXAMPLE:-

STREETLIGHT

Adetail drawings in this manual.

appears on relevant construction

Type shown within dashed box

3 = Nostalgia Type 2 (blue/grey)

STREETLIGHT LED LUMINAIRE MINOR ROAD CONSTRUCTION TYPE

SLED GL 0170 N

LUMINAIRE TYPE

N = Normal (semi cut-off)

A = Aeroscreen (full cut-off)

1 = Nostalgia Type 1 (green)

2 = Nostalgia Type 1 (black)

SLED = Streetlight LED

SUPPLIER IDENTIFIER

GL = Gerard Lighting

GE = GE

BILLABLE LOAD

0170 = 17W

0219 = 21.9W

0250 = 25W

0300 = 30WSLED GL 0170 N = Streetlight LED, Gerard Lighting, 17.0W, Normal

SLED GL 0170 3 = Streetlight LED, Gerard Lighting, 17.0W, Nostalgia Type 2 (blue/grey)

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

22/11/16

Page 6: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =
Page 7: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

14.03.14B

(

STREETLIGHT

S = Streetlight

POLE TYPE MOUNTING HEIGHT No. OF OUTREACH

1 = Single

2 = Double

OUTREACH DIMENSION

15 = 1.5m

FOUNDATION TYPE

PC = Precast

CI = Cast in situ

is constructed by others

Omit where foundation

EXAMPLE:-

EXAMPLE:-

STREETLIGHT POLE / FOUNDATION CONSTRUCTION TYPE

EXAMPLE:-

EXAMPLE:-

STREETLIGHT

SL = Streetlight

LAMP TYPE AND WATTAGE

STREETLIGHT LUMINAIRE MINOR ROAD CONSTRUCTION TYPE

SL HPS 0001

HPS = High Pressure Sodium Vapour

LF = Linear Fluorescent

CFL = Compact Fluorescent

MH = Metal Halide

PRODUCT CODE

0001 = Sylvania Suburban 70W HPS

0003 = Sylvania Suburban 32W CFL

0005 = Sylvania Suburban 35W MH

0007 = Sylvania Suburban 70W MH

0002 = Sylvania Urban Aeroscreen 70W HPS

0004 = Sylvania Urban Aeroscreen 32W CFL

0006 = Sylvania Urban Aeroscreen 35W MH

0008 = Sylvania Urban Aeroscreen 70W MH

)

65 = 6.5m

75 = 7.5m

S B 75 1 15 PC

(Steel)

B = Base Plate Mounted I = Integral

SB75115PC = Streetlight, base plate mounted pole, 7.5m mounting height, single 1.5m outreach including precast foundation.

SB65215 = Streetlight, base plate mounted pole, 6.5m mounting height, double 1.5m outreach, no foundation.

SLHPS0001 = Streetlight, High pressure sodium vapour, 70W

SLMH0005 = Streetlight, metal halide, 35W

1-6-2-5

1 6 2-5 0C

LIGHTINGCOLUMNS MINOR ROAD - ENERGEX ONLY

CONSTRUCTION TYPE GUIDE

BPM POLE / FOUNDATION & LUMINAIRE

10500-A4-1-6-2-5

NIL

NIL

23.10.14C

0032 = Greenstreet T5 2 x 24W

0033 = Greenstreet T5 2 x 14W

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

01/04/16

01/04/16

01/04/16

14/10/10

Page 8: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

EXAMPLE:-

EXAMPLE:-

Adetail drawings in this manual.

appears on relevant construction

Type shown within dashed box

1-6-2-6

1 6 2-6 0A

LIGHTINGCOLUMNS MINOR ROAD - ENERGEX

CONSTRUCTION TYPE GUIDE

LED LUMINAIRE

10500-A4-1-6-2-6

NIL

NIL

STREETLIGHT LED LUMINAIRE MINOR ROAD CONSTRUCTION TYPE

SLED GL 0170 N

LUMINAIRE TYPE

6 = Nostalgia Type 2 (blue/grey)5 = Nostalgia Type 2 (black)4 = Nostalgia Type 2 (green)3 = Nostalgia Type 1 (blue/grey)2 = Nostalgia Type 1 (black)1 = Nostalgia Type 1 (green)A = Aeroscreen (full cut-off)N = Normal (semi cut-off)

BILLABLE LOAD

0300 = 30W0250 = 25W0170 = 17W

SUPPLIER IDENTIFIER

GE = GEGL = Gerard Lighting

STREETLIGHT

SLED = Streetlight LED

SLED GL 0170 N = Streetlight LED, Gerard Lighting, 17.0W, Normal (semi cut-off)

SLED GL 0170 6 = Streetlight LED, Gerard Lighting, 17.0W, Nostalgia Type 2 (blue/grey)

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

23/03/17

Page 9: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

MATERIAL - POLE

814-1

818-1

MATERIAL - LUMINAIRE

ASSY DESCRIPTIONQTY

NOTES:

1. Access door to be on side of pole that is least

(normally on opposite side to oncoming traffic).

2. Neutral and earth terminals of terminal panel

are to be bridged. Make bridge only after polarity

has been established.

3. Ensure contact area between Base Plate and

hold down bolt washers is clean, free of paint,

and bolts are tight.

Foundation cast in situ depth 1.2m

Foundation precast concrete depth 1.2m

TYPE 2TYPE 1QTYDESCRIPTIONASSY

Pole 4.5m Nostalgia

Green

814-2

814-3

814-4 Navy

1

1

QTYDESCRIPTIONASSY

1

816-3

1

1

Luminaire Notalgia Type 1 Green

Luminaire Nostalgia Type 1 Black

S70

Terminal panel and cable to Nostalgia

MATERIAL - FOUNDATION

840-1

855-1

Blue/Grey

Black

B 14.01.13

hazardous to maintenance personnel

816-14 CF32

816-9 S70

816-17 CF32

816-12 S70

816-20 CF32Luminaire Nostalgia Type 1 Blue Grey

843-3

Luminaire Nostalgia Type 2 Green

Luminaire Nostalgia Type 2 Black

S70

843-11 CF32

843-6

843-14

843-9

843-17

Luminaire Nostalgia Type 2 Blue Grey

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

01/10/10

C 04.02.14

D 05.01.16

816-21

816-22

816-23

L17

L25

L30

816-24

816-25

L17

L25

843-18

843-19

843-20

E 16.08.16

1-6-3-1

1 6 3-1 0E

LIGHTINGCOLUMNS MINOR ROAD

BPM STEEL POLE / FOUNDATION

NOSTALGIA TYPES 1 & 2 - MATERIAL

10500-A4-1-6-3-1

5 85 8041 2

4927-A4-6.8, 6.9

816-28 L30

816-29 L30

843-21 L17

843-23 L25

843-25 L30

843-22

843-24

843-26

S70

CF32

L17

L25

L30

S70

CF32

L17

L25

L30

Page 10: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

F

F F

F

F

F

F

F

TYPE-2TYPE-1

ROAD

SIDE

PROPERTY

SIDE

Assy 818-1

ROAD

SIDE

PROPERTY

SIDE

40 Gro

ut

50

Assy 818-1

Construction Type

(Luminaire)

SLNOS

SLN

(Pole & Foundation)

Drawing No. 1-4-7-1.

Refer Services

Underground service.

855-1

840-1 or

Assy Selection

814-1 to 4

Assy Selection

4.5m

Height

Pole

814-1 to 4

Assy Selection

B 14.01.13

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

14/10/10

C 04.02.14

D 05.01.16

14 & 17 - 26

843-3, 6, 9, 11,

Assy Selection

or 1-2-855 note 5.

refer drawing no. 1-2-840 note 6

For unsuitable soil conditions

E 16.08.16

1-6-3-2

1 6 3-2 0E

LIGHTINGCOLUMNS MINOR ROAD

BPM STEEL POLE / FOUNDATION

NOSTALGIA TYPES 1 & 2 - CONSTRUCTION

10500-A4-1-6-3-2

5 85 8041 2

4927-A4-6.8, 6.9

17 & 20 - 25, 28, 29

816-3, 9, 12, 14,

Assy Selection

SLED(LED Luminaire)

Page 11: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

F

F F

F

MATERIAL - POLE

QTYDESCRIPTIONASSY

815-1

815-2

818-2

MATERIAL - FOUNDATION

ASSY

MATERIAL - LUMINAIRE

ASSY DESCRIPTION QTY

DESCRIPTION

NOTES:

Double outreach

Traffic flow

DOUBLE OUTREACH POLE ORIENTATION

Terminal chamber door

Traffic flow

Pole 5.5m Base Plate Mounted steel

Outreach arm 1.5m single

Outreach arm 1.5m double

Foundation cast in situ depth 1.2m

Foundation precast concrete depth 1.2m

Luminaire normal lamp and PE cell

Luminaire aeroscreen lamp and PE cell

AR

1

1

1

DOUBLESINGLE

OUTREACH

1

1

OUTREACH

QTY

SINGLE

OUTREACH

DOUBLE

OUTREACH

872-4

S70

CF32

H35

H70

4.5m & 5.5m POLE

Foundation cast in situ depth 1.5m (Ergon only)

Foundation precast concrete depth 1.5m (Ergon only)

1

1 1

Minor Road Terminal panel and cable

1-6-4-1

1 6 4-1 0D

LIGHTINGCOLUMNS MINOR ROAD

BPM STEEL POLE / FOUNDATION

SINGLE DOUBLE OUTREACH - MATERIAL

10500-A4-1-6-4-1

5 85 8042 2

NIL

840-1

840-2

855-1

855-2

818-3 Minor Road Terminal panel and cable to double outreach

B 14.01.13

817-3

817-9

817-11

817-12

817-7

817-13

817-14

817-15

CF32

H35

H70

S70

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

01/04/16

01/04/16

01/04/16

14/10/10

C 18.12.13

900-1

900-2

2 x 14W LF

2 x 24W LF

D 10.06.15

approved poles.

approved poles. Refer to QPLDM for

4. LED luminaires are only to be installed on

(normally on opposite side to oncoming traffic).

hazardous to maintenance personnel.

1. Access door to be on side of pole that is least

has been established.

are to be bridged. Make bridge only after polarity

2. Neutral and earth terminals of terminal panel

and bolts are tight.

hold down bolt washers is clean, free of paint,

3. Ensure contact area between Base Plate and

L22817-20

817-30 L22A

817-31 L25

Page 12: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =

F

F

F F F

F

SIDE

ROAD

SIDE

PROPERTY

40 Gro

ut

5

Assy 815-1Assy 815-22.0m

50

o

SLBPM

SL

Construction Type

(Pole & Outreach/Foundation)

(Luminaire)

Drawing No. 1-4-7-1

Refer Services

Underground service

BPM BASE PLATE MOUNTED

855-1 or 2

840-1 or 2 or

Assy Selection

or 1-2-855 note 3.

refer drawing no. 1-2-840 note 6

For unsuitable soil conditions

Assy 872-4

7.5m

Height

Mounting

Nominal

5.5m

Height

Pole

1-6-4-2

1 6 4-2 0E

LIGHTINGCOLUMNS MINOR ROAD

BPM STEEL POLE / FOUNDATION

SINGLE DOUBLE OUTREACH - CONSTRUCTION

10500-A4-1-6-4-2

5 85 8042 2

NIL

818-2 or 3

Assy Selection

B 14.01.13

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

14/10/10

C 18.12.13

D 10.06.15

817-20 or 30 or 31 (Refer note 4 Sh 1)

900-1 or 2 or

817-3, 9, 11, 12, 13, 14 or 15 or

Assy Selection

E 23.03.17

SLED (LED Luminaire)

Page 13: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =
Page 14: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =
Page 15: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =
Page 16: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =
Page 17: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =
Page 18: LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileSL N 1 CF32 SL NOS 1 PC ( ) STREETLIGHT SL = Streetlight EXAMPLE:-EXAMPLE:-POLE NOS = Nostalgia FOUNDATION TYPE PC = Precast CI =