POWERWAVE Tower Mounted Amplifiers
DL Insertion Loss (dB) 0.4 dB, Typical
Intermodulation @ 2 x +43 dBm Tx carriers, In receive band, <- 116 dBm, referred to Antenna port (<-159 dBc)
DL Frequency Range (MHz) 1930-1990
DL Return Loss > 18 dB
Input Voltage (V) AISG Mode: 10-30; Current alarm mode: 9 -17
Power Handling, RMS >53 dBmAISG Compatibility
LGP18601, 06 no AISG; LGP18607, 10 AISG 1.1 (field upgrdable to AISG 2.0), LGP18617, 20 AISG 2.0
Alarm Functionality LGP18606: 170-190 mA alarm current; LGP18601: current alarm compatible with PDU LGP121nn; LGP18607, 10, 17, 20 AISG compatible or in case of no AISG command received current alarm mode: LGP18610, 20: 170-190 mA; LGP18607, 17: current alarm compatible with PDU LGP121nn
Power Consumption @12 VDC, 1.5 W per LNA
UL Rejection >80 dB
UL Gain(dB) 12
ELECTRICAL SPECIFICATIONSUL Frequency Range (MHz) 1850-1910
UL Return Loss >18 dB
UL Bypass Loss(dB) < 3.0 dB, Typical
UL Max Input Power (dBm) +12
UL Noise Figure 1.5 dB, Typical
UL Output 3rd Order Intercept Point(dBm) +26 dBm, Typical
Colors Off white (NCS 1502-R)
RF Connectors DIN 7/16 female
Mounting Kit Mounting kit for pole and wall is included
MECHANICAL SPECIFICATIONSDimension HxWxD mm(ft) 169 x 272.5 x 67.7 (7”x11”x3”)
Weight(lbs) <4.5kg (9.9 lbs)
EMC FCC Part 15
Safety UL60 950, ETL
APPROVAL AND TESTS
Housing Aluminum
Lightning Protection 3 kA 10/350 µs; 20 kA (Shield)
Ingress Protection IP 68 (LGP18601, 06 upgraded from IP65 to IP68 week 36 2011)
MTBF >1 million hours
Storage ETS 300 019-1-1
Temperature Range -40° C to +65° C (-40° F to +149° F)
ENVIRONMENTAL SPECIFICATIONS
Transportation ETS 300 019-1-2
Operational ETS 300 019-1-4
LGP186nn Twin Dual Duplex 1900 MHz Full Band
*All specifications subject to change without notice. Contact your Powerwave representative for complete performance data.
D031-08220 Rev C Updated: 2011-09-08 © Copyright 2011 Powerwave Technologies, Inc. All rights reserved.All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.