L’elettrotecnica, l’elettronica e gli aerei
Generatori aerei passeggeri: 1 motore di avviamento principale/generatore, 2 auxiliary power unit (APU), 3 emergency ram air turbine (RAT), 4 groundpower unit (GPU) (da J. F. Gieras, Advancements in Electric Machines, Springer 2008)
Motore turboelica e generatori azionati dal motore
Provide power to start the main enginesTurbine engines must be accelerated to a high rotational speed in order to provide sufficient air compression for self-sustaining operation. Before engines are to be turned, the APU is started, generally by a battery or hydraulic accumulator. Once the APU is running, it provides power to start the aircraft's main engines
Many series -500 aircraft have an extra, dedicated APU battery to preserve main battery usage
APS 2000 APU del Boeing 737. 1 light switch, 2 APU fuel line,3 generator, 4 oil filter, 6 fuel nozzles, 7 upper shroud, 8 bleed air valve, 9 start motor, 10 oil tank, 11 bleed air manifold, 12 exhaust muffler
APU sul Boeing 737:carenatura APU ingresso aria di raffreddamento al
di sopra dello scarico
Ram air turbine of Airbus A320 located under left wing
Applicazione:generatore di tensione alternativa-sinusoidale(alternatore)
AC & DC Metering panel - Classic
Residual Volts: per testare un generatore che va fuori lineaSchiacciato il pulsante, se si vede tensione il generatore ruota ancoraSe son mostrati 0 V, è guasto e non sarà ricollegatoResidual volts: la sola selezione che usa la scala di 30 V sul voltmetro AC
AC & DC Metering panel - NG
CAB/UTIL IFE/PASS SEATRecirculation fan(s) 115V AC audio
IFEDoor area heaters 115V AC video IFE
Drain mast heaters 28V DC video IFE
Lavatory water heaters
Airphone equipment
All galley buses Pax seat elec outlets
Shaver outlets Logo lights Potable water comp
BatterieBatteria 36 Ah, 24 V, 20 celle, Nickel-cadmium 30 minutes (20 mins 1/200's) of standby power if all other generators fail.Batteria APU - opzionale – principalmete per avviare l’APU (auxiliary power unit);anche in parallelo con la batteria principale45’ di alimentazione standby
Batteria Ausiliaria – di riserva sul NG – normalmente isolata, unless the main battery is powering the standby system when it operates in parallel with the main battery. The aux battery combined with the main battery will provide 60’ of standby powerNG: 2 extra dedicated batteries for the engine and APU fuel shut off valves and the ISFD (150’ capacity).
BAT OVHT & APU BAT OVHT (overheat, surriscaldamento) lights are a customer option on classics. They are located on the aft overhead panel and no crew action is required if they should illuminate.
RADAR - RAdio Detection AndRanging
The TCAS algorithm selects the maneuver “sense” that provides the largest separation at the predicted closest point of approach (CPA)